{"Bundles":[{"AllowVibSigBypass":"false","AvailabilityNotes":[],"BundleXML":"bp008264.xml","Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Contents":[{"Name":"CP066007.zip","ProductId":"df6ba3c2e569412ab3999b9575ddb1d8","VersionId":"b900be4b099045c3a7fa9b0424ade33a"},{"Name":"Seagate_CimarronBP_SCIMARBPNTG4.fwpkg","ProductId":"799a5476ba934d049a4150e04e75c398","VersionId":"598a471de19b4292a91b0bdd450b8133"},{"Name":"cp068646.exe","ProductId":"ffbc55840f92498790e9569c6abb14d8","VersionId":"40522dcb139844feadb9548f07c0d61f"},{"Name":"cp070454.exe","ProductId":"3771cd39413d469099d505f7db47003a","VersionId":"c28f2857d33846b1a33081f250a3086a"},{"Name":"CP069161.zip","ProductId":"605b084308a74c74a0091e855e41c6f1","VersionId":"85aeeef1c2034ddc9dcbc6b49de2e41b"},{"Name":"Micron_7450_M7450ALLHPK4.fwpkg","ProductId":"f85aacf9018c4fbdadcdb2b9bbf03fed","VersionId":"b8cf44de46d94ae9b0f6781016022a00"},{"Name":"firmware-hdd-92d876cfea-4ICRHPK3-15.1.x86_64.rpm","ProductId":"8adb99f8960b4849ba6664217211b8d2","VersionId":"c40a36ef0eb14c6ca2d92be35d8d3f1d"},{"Name":"firmware-system-a48-4.00_2026_01_09-1.1.x86_64.rpm","ProductId":"1e4f77062f4d48c8906f4212d8016a76","VersionId":"af561872949a41e4988e41204dc31af0"},{"Name":"CP065939.zip","ProductId":"d54c971d2c3047569ed2e37939cd2848","VersionId":"c510b3b7041e47f49b7d1a76cb4bb0d0"},{"Name":"cp069531.exe","ProductId":"30c69f83193c4f679a84938a219df0d6","VersionId":"632a6a19bde74e7ba9fc81827ee304df"},{"Name":"cp068741.exe","ProductId":"3c5ca1f7884d46278989b90e474b83e1","VersionId":"a832d5a21a8241718cd47976433f543c"},{"Name":"U39_3.62_01_09_2026.fwpkg","ProductId":"5410a19b6b464f26bd8935266bc1120d","VersionId":"d1a911361fe6483282f96e6670920d8e"},{"Name":"Micron_7450_Micron_7450_M7450ALLHPS3.fwpkg","ProductId":"5b36200ffa3640839369c39ca58c8134","VersionId":"be4575b6b0d64fc097f43ac471267831"},{"Name":"ilo5_317.fwpkg","ProductId":"2dc80c4ae4b943faadb938f8fc2b61d5","VersionId":"fea07870ce3c4a4f9091b26b3afc167f"},{"Name":"CP069051.zip","ProductId":"d65fb45f0327449eb7763d2d9cb7bf3e","VersionId":"1e9464560bd248a3b51eb190a3961008"},{"Name":"20_43_8002-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","ProductId":"6ca4dd262131408db10af90451555128","VersionId":"2d415f93654b420ba4457f2e61d3f10d"},{"Name":"CP065987.zip","ProductId":"cc96bd351eff4426bf37f3da741a7623","VersionId":"2e372effed5940ee9e19594f3202980c"},{"Name":"HPE_MR216i-a_Gen10P_52.32.3-6333_A.fwpkg","ProductId":"2b01702f6be343c09f8208f8aab17afb","VersionId":"e2e72b1069984e4d976cf087ff061b20"},{"Name":"firmware-nic-bcm-nxe_1.25.5-1.1_amd64.deb","ProductId":"1860b8cf54d04500a5555e0fcde5c087","VersionId":"98f7805e77a347d6a1d5b815f3e75d52"},{"Name":"firmware-hdd-a27c95663d-HPK6-5.1.x86_64.rpm","ProductId":"19d0fae1d2d44133a57fe6d71c8af4b7","VersionId":"378e98a7adff433fa1102dd3d475f523"},{"Name":"CP067553.zip","ProductId":"d1014161143144dea5631e9b65f9f0d4","VersionId":"06051d7daea64c1298ab526d42c02f0d"},{"Name":"firmware-hdd-1a541ed00d_0GPK6-1.1_amd64.deb","ProductId":"cf9a5479d0b3462eb307d2e0e0608dfc","VersionId":"c0a439bd7e5943eda0dce2220587ae9a"},{"Name":"firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1.x86_64.rpm","ProductId":"da6c398c130f48f9a5a32bd3c9213a90","VersionId":"fa591683ed42453dbe23fd462a1141c2"},{"Name":"U30_3.62_01_09_2026.fwpkg","ProductId":"ab0976902eae4e0c8757219b825c91f8","VersionId":"444b43a6c8054a7383b4a035742b4521"},{"Name":"firmware-hdd-8a0371a425_0HPDC-1.1_amd64.deb","ProductId":"71ab729e72394b149248324ae1538718","VersionId":"c2a73f8d43b0403798a1a35e33fa8599"},{"Name":"cp070011.exe","ProductId":"6c76dfc1e26441a48559e0f1bee2891e","VersionId":"84d057a1e5e94d29a1ab371c43d77369"},{"Name":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","ProductId":"22b29694299c4b27b67b3dde603d40b0","VersionId":"ab6c65b0ce4b49bca8e05fdc25ac1fe0"},{"Name":"CP065990.zip","ProductId":"a6447acbde7f4368991a3df1503f91e8","VersionId":"b4d49336f3f94c119afb40b5f43eca2c"},{"Name":"firmware-system-u46-2.54_2026_01_09-1.1.x86_64.rpm","ProductId":"4eb73551b4784537817e4ada8a1d49b5","VersionId":"b2cb8d1cc3a04c0ea1356c190738f95e"},{"Name":"HPE_E810_XXVDA2_SD_4p90_PLDMoMCTP_80020EF6.fwpkg","ProductId":"0134d053d49b43b1add04e5a51f6ff18","VersionId":"4a33e9a012cf43b0b4d081cb20efe851"},{"Name":"U38_3.62_01_09_2026.fwpkg","ProductId":"703e98acf33d484a9d2825573e86e8c0","VersionId":"6cf3611460fb4de68af31feb6fe318b2"},{"Name":"cp066306.exe","ProductId":"C8510","VersionId":"d4821d1767e84242b8aa47442f6595fe"},{"Name":"firmware-nic-bcm-open-2.42.0-1.1.x86_64.rpm","ProductId":"110c3bd2bca349b2ba7b9fec9e58ee8d","VersionId":"677f3af9d2954ecd965a37466bfc142d"},{"Name":"HPE_UBM3_1.24_G.fwpkg","ProductId":"df57af7543b34ffbb722ca05255bf445","VersionId":"bc8e3b1eb8804b47acb76ad46bb94011"},{"Name":"kmod-ice-2.3.10-1.rhel10u0.x86_64.rpm","ProductId":"a00e6ed1db904ebf80004d7820172e46","VersionId":"fe7f5d92134d4c4aa083c5e202d97d20"},{"Name":"firmware-hdd-8173816d98-HPD6-3.1.x86_64.rpm","ProductId":"6ee949809c8346d9b5134787ab827a8a","VersionId":"f94eb54b3b1c4a1da2fcfa19d0ece105"},{"Name":"cp070182.exe","ProductId":"321dd379dd1a436ab919b4529b332ece","VersionId":"e00cbb21eadc48ea811fbfcdec36db33"},{"Name":"firmware-hdd-fa46c607d6-HPD5-7.1.x86_64.rpm","ProductId":"aedaa041caed4345872545de3f1efa40","VersionId":"b47b01f6dc454b40bb37c8e853ce5612"},{"Name":"H08_3.62_01_09_2026.fwpkg","ProductId":"f14326f2e6af456689e2c8b0aa9341c7","VersionId":"e80e817902e74a5e9d929bb6456254e2"},{"Name":"firmware-smartarray-7b5e8400dd-1.27-6.1.x86_64.rpm","ProductId":"b94490ecb4854ca6989ed2491e061c4b","VersionId":"81f6023a6657428ba79e3359d882e95f"},{"Name":"cp062283.exe","ProductId":"b75caf763a204707bef1840fcde5be6a","VersionId":"07a6f72217b54f3fa879777aa74068af"},{"Name":"kmod-netxtreme2-7.15.25-1.rhel9u5.x86_64.rpm","ProductId":"81cb1e1fa07441fc9994562f591c5c30","VersionId":"a37f275906d742b1a7bfb6ca8463a9d7"},{"Name":"kmod-netxtreme2-7.15.25-9.rhel9u6.x86_64.rpm","ProductId":"81cb1e1fa07441fc9994562f591c5c30","VersionId":"a37f275906d742b1a7bfb6ca8463a9d7"},{"Name":"mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm","ProductId":"1d4bdf01ac864288af51e73784711598","VersionId":"d95407aea34f4c9684e045b42ce5992b"},{"Name":"kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm","ProductId":"1d4bdf01ac864288af51e73784711598","VersionId":"d95407aea34f4c9684e045b42ce5992b"},{"Name":"28_46_3048-MCX75310AAS-HEAT_HPE_Ax.pldm.fwpkg","ProductId":"6aac2d7fdad54ca7910ee0bb1e81d6f3","VersionId":"4aecd28ce4dd4b41827a4c3da3244ebc"},{"Name":"firmware-nic-intel-1.35.0-1.1.x86_64.rpm","ProductId":"d8c86b5c3ce7444dbebf7bd215bf1a32","VersionId":"435b77df42df4c90b70b025c94cca18d"},{"Name":"firmware-hdd-3d97759111_0HPDB-1.1_amd64.deb","ProductId":"e9e7d66071a042078eec11daa5bcf114","VersionId":"a9f53cc9e0ca42a59f10422a1fc318f8"},{"Name":"firmware-hdd-24384980ec_0HPD2-1.1_amd64.deb","ProductId":"9c8cb2fad4c14cc880a30a5cd84639ec","VersionId":"aa48a757155d4eb09cbd5a6511149837"},{"Name":"cp068644.exe","ProductId":"9141b4ee76c74b70a4eb2f021bfa217f","VersionId":"2ba38c58637a46b988c479eb0055307b"},{"Name":"cp068759.exe","ProductId":"d05a1433339f497faa2734fb31c015eb","VersionId":"0bf8a3966c3a47fb902a7994b439e771"},{"Name":"firmware-hdd-24fe569b72-HPD6-2.1.x86_64.rpm","ProductId":"779f4f17fec64b6b9acf9ede668fc68a","VersionId":"8743e3c43b1a4290be022781533c69f9"},{"Name":"U61_2.52_01_09_2026.fwpkg","ProductId":"a96fcafbb6d4411b8c5383684726a0e9","VersionId":"0e26d2b72d7043b084164e94cd7643f3"},{"Name":"CP067623.zip","ProductId":"be910528f863487899cf62f353be4a46","VersionId":"eeb16633cbf44ee9bee1fee95905ee44"},{"Name":"28_46_3048-MCX75310AAS-HEAT_HPE2_Ax.pldm.fwpkg","ProductId":"f56420e1793d48958fc061b802e973db","VersionId":"17783bd8d16a49f781a100aa2b247a61"},{"Name":"cp070354.exe","ProductId":"bf6c1988a6474823969dd84808070288","VersionId":"1cf368babea4460ea28bf99e128195c7"},{"Name":"firmware-hdd-aef2a690c9-HPG5-13.1.x86_64.rpm","ProductId":"29456540dcc74eaf9f223e63cf50eff7","VersionId":"89e45fac4c3a461283ecd1b976bd4f35"},{"Name":"firmware-hdd-035a863453-HPK5-11.1.x86_64.rpm","ProductId":"fdd1b58860474c42b7f3b1b7524af387","VersionId":"d4c8d4a771074416b3a178335cb8f110"},{"Name":"firmware-e910-intel-nic-fw-pack-4.30-2.1.x86_64.rpm","ProductId":"c02bbf9a9f6640aeab2edb3ce124d6c6","VersionId":"fd310372a5564e71840f3748ee5da105"},{"Name":"firmware-nic-mellanox-ethernet-only-1.0.24-1.1.x86_64.rpm","ProductId":"5c045315a07d45779f552f6cb831a2b4","VersionId":"3d95aa829f2f49a4ba59bee0a711d446"},{"Name":"firmware-system-u64-2.52_2026_01_09-1.1.x86_64.rpm","ProductId":"716670787e144aa5b4cf080bc78d2ef7","VersionId":"8d47c2e051af4a49a4a9dc67d04a9b60"},{"Name":"amsd-4.5.0-2107.2.sles15.x86_64.rpm","ProductId":"cd4b5a9c9ed9405abbc5be7a9f037870","VersionId":"e555c747268a4d7799f6ca1b18532b09"},{"Name":"cp069948.exe","ProductId":"e8f02987fae14861a37eb27a43adf117","VersionId":"56e5ef487c144df4910e6fecc8a7f3e2"},{"Name":"cp070247.exe","ProductId":"ccbfcdbdc47644e7ab18a371d4af9d7a","VersionId":"940f79d811274c30986b84856604888d"},{"Name":"cp069693.exe","ProductId":"21c71338fdf2430b8b41f3737620822c","VersionId":"6eae68baade34fceb2f671e066ac6a3b"},{"Name":"cp067967.zip","ProductId":"39040fa72ee34e15b8d90d8ca174f1ed","VersionId":"e2e71b0d29dc4fc9882f74b75f786875"},{"Name":"CP068325.zip","ProductId":"7a882d320d3b437c96a87679f2b6ee8f","VersionId":"515578fa1a934894b2b926c44a093dc2"},{"Name":"cp068660.exe","ProductId":"54856ac460a544e2985eadac24abf907","VersionId":"20b1a055d4a5499fae9cd0a73758b919"},{"Name":"firmware-hdd-41cdb1c9da_0HPG3-1.1_amd64.deb","ProductId":"36ccc302b9a748a8a9762bf721813e29","VersionId":"a5a54b9887064197bd2076afeaca5fba"},{"Name":"cp068542.zip","ProductId":"a07f8ac11b4a440d99aa61ea5fb0b63f","VersionId":"2726ab012ef34fed81d4afe7df3657cd"},{"Name":"HPE_E810_XXVDA2_SD_OCP_4p90_NCSIwPLDMoMCTP_80020F00.fwpkg","ProductId":"fbb53cf22a594dbb99b8c7f89e562124","VersionId":"bdc9a8b02b6241b7951dc5b9109c27bd"},{"Name":"firmware-hdd-54addf5312_0HPK4-1.1_amd64.deb","ProductId":"25c9026167b24747b0b74c8f6d82b804","VersionId":"703e8c7554a8414c8a902173ea0a4257"},{"Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-235.1.164.14.sles15sp6.x86_64.rpm","ProductId":"2ed4fb56e81f45b0b8ae601a61b78e6c","VersionId":"417cb571a27e44a5b9cd0ee1e069f9cc"},{"Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-235.1.164.14.sles15sp7.x86_64.rpm","ProductId":"2ed4fb56e81f45b0b8ae601a61b78e6c","VersionId":"417cb571a27e44a5b9cd0ee1e069f9cc"},{"Name":"cp066323.exe","ProductId":"07117e80b64248dab9811a2280fcc85e","VersionId":"7e1d0f75ed5a42b6bef323ccfb8431c5"},{"Name":"firmware-hdd-492a9952f6-HPG5-5.1.x86_64.rpm","ProductId":"fde211973c7e4009ac1207f980953529","VersionId":"5a63b21feb2248f7a2d9ef079143a6ce"},{"Name":"U60_2.52_01_09_2026.fwpkg","ProductId":"31e3c0de86a045739aadd70ea35e114f","VersionId":"0bda68cec50448d1a235fdf4bee72151"},{"Name":"cp069741.exe","ProductId":"bdb6e242313a47b89b69823cf9ad3729","VersionId":"04f87cceff14489ab59f8885137cf80f"},{"Name":"Micron_7500_Micron_7500_M7500ALLHPK1.fwpkg","ProductId":"90a21d24fe854b07a035a8e7bf0e3602","VersionId":"738d3ecbd42b4b8d832987815cfae4d4"},{"Name":"cp069698.exe","ProductId":"e1ccea24a14a427dabc2aadd846feea9","VersionId":"05da01a50f8d4475a07703fd7a94ee16"},{"Name":"firmware-hdd-9ad359dac1-HPDB-5.1.x86_64.rpm","ProductId":"c47b4b11bb744418a62b9ae668fd0ea6","VersionId":"d11dc139e4384368a01dad304534da0b"},{"Name":"firmware-hdd-d550523365_0HPD3-1.1_amd64.deb","ProductId":"44ae296c36cb4decaa8bbd5cfce5396e","VersionId":"b08bc18464a74808a9489c7e6efe800c"},{"Name":"cp068659.exe","ProductId":"63976963938d4f79be04f7b652abb966","VersionId":"7d67acb393844eddb9adb9967c42ac81"},{"Name":"firmware-system-u39-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"25afa565c5cd4e359629eee44baf7e64","VersionId":"380cc747b4dc404998a6462b4cdd39cf"},{"Name":"ssacli-6.60-8.0_amd64.deb","ProductId":"32e70edc717a4f199fb4d966f5a2ab73","VersionId":"6d7d824703a54b4eb0ddfa9e33236529"},{"Name":"firmware-hdd-c7df7ceedb_0HPD9-1.1_amd64.deb","ProductId":"fde13e5a19194ad9adab9161f8d35a15","VersionId":"234715b12d774bb5b0159bcadbca8225"},{"Name":"amsd-4.5.0-2107.2.rhel10.x86_64.rpm","ProductId":"fc90f99dec3d4432a73ac738a336cdc1","VersionId":"66307d72ad4a44f2872b8c8fbb857b13"},{"Name":"cp070296.exe","ProductId":"6d1ce52e0d6c4c48a4cc6f903852d87d","VersionId":"86c6a30ddec54f759ee2ce126d557ef5"},{"Name":"cp069583.exe","ProductId":"56422dc0cdb64171addc0c9909a7019a","VersionId":"a0c3d168572b48d3a6ff85d62c1ff987"},{"Name":"HPE_E810_XXV4T_O_SEC_4p90_PLDMoMCTP_80020EF5.fwpkg","ProductId":"6a4f9209b5474891beaf50886f41470e","VersionId":"1df1d3ff1185490f9ec18bb596489941"},{"Name":"cp068480.exe","ProductId":"b929c06b33df46a182acd3e907e0dc53","VersionId":"5d5483b2796f4400add5ab4e7a1c9ae3"},{"Name":"firmware-hdd-3d97759111-HPDB-4.1.x86_64.rpm","ProductId":"eca7d77c8ba84ffe9014dfb5c3b6ee15","VersionId":"de21450efdd548ebb29ded49e6e88ec9"},{"Name":"ssa-6.60-8.0_amd64.deb","ProductId":"930ec7c21c864080921bd1f4201e5153","VersionId":"52828cfeee2f45ba846e927c3996d180"},{"Name":"firmware-hdd-a886842a99-HPD2-10.1.x86_64.rpm","ProductId":"9ea83d5d4cdf449690664479d7c8538a","VersionId":"5c2b3957b6e54829a9ca2b3d680db848"},{"Name":"kmod-qlgc-fastlinq-8.76.2.0-1.rhel9u5.x86_64.rpm","ProductId":"1aa231a863f54088aaed47c33f55bded","VersionId":"89dde2a39dfb4d64a8652e6a68b10854"},{"Name":"kmod-qlgc-fastlinq-8.76.2.0-10.rhel9u6.x86_64.rpm","ProductId":"1aa231a863f54088aaed47c33f55bded","VersionId":"89dde2a39dfb4d64a8652e6a68b10854"},{"Name":"firmware-hdd-8fafc9efb2_0HPD8-1.1_amd64.deb","ProductId":"7dc47244be094f2084e0e71968443832","VersionId":"96c8e9481e97435d8f4f1483ebbb03da"},{"Name":"CP064920.zip","ProductId":"aa3d4b3746e2485289f458134b1187cd","VersionId":"114f2e8b6d9e4deea39e74ff427c00e2"},{"Name":"cp067853.zip","ProductId":"d93273aa12774694887dc3aab21ae996","VersionId":"fb37b7e36bfb498092b85a8f201267a6"},{"Name":"cp068625.exe","ProductId":"d026cab87ecf46f4a70676c4643d63f0","VersionId":"292d8b1e06bf4f8796fc78a8edb69243"},{"Name":"smartpqi-kmp-default-2.1.38-022.sles15sp7.x86_64.rpm","ProductId":"ddc8bdca3abc4ab8823e820be1ed4dfd","VersionId":"fa241aa0a39b4f01acb7dcad24b81808"},{"Name":"smartpqi-kmp-default-2.1.38-022.sles15sp6.x86_64.rpm","ProductId":"ddc8bdca3abc4ab8823e820be1ed4dfd","VersionId":"fa241aa0a39b4f01acb7dcad24b81808"},{"Name":"CP065940.zip","ProductId":"8a5f6b85a2a94dc58e5d42c516c7060a","VersionId":"6b0b91b47e2f4d9189480894f7b1ba61"},{"Name":"firmware-hdd-faf39e0ff7-HPD9-10.1.x86_64.rpm","ProductId":"fcf6b49416e1460393e2103c04483878","VersionId":"026217c0626d4029b3c39b733ef408bc"},{"Name":"CP065978.zip","ProductId":"a6c377914cad4568810f0a24fc0faa52","VersionId":"828713c2b35a4640b56377bf5971b97b"},{"Name":"firmware-dl20ml30gen10sps-05.01.05.103-2.1.x86_64.rpm","ProductId":"e9b531c475a54ce6b287402b5c425933","VersionId":"4b840130fd674097a45e2ff3ef245086"},{"Name":"CP065979.zip","ProductId":"eacabd6c758c41759c1c132130d3f614","VersionId":"81a0178ad61c4266ba2c2e5a85a13a6a"},{"Name":"kmod-qlgc-qla2xxx-10.02.15.00_k1-1.rhel10u0.x86_64.rpm","ProductId":"4a6cd8bdbba64726bce1bd7c81b875da","VersionId":"ec0dd59b68c94940804f8e3ae0c08dc6"},{"Name":"firmware-hdd-54addf5312-HPK4-3.1.x86_64.rpm","ProductId":"3d004333c656491289fdf09d5881fcdd","VersionId":"7ebf0ab82df74654bb70a9bc314fc227"},{"Name":"firmware-hdd-9475583fb5_0HPG1-1.1_amd64.deb","ProductId":"0a50ffd5675c4918bbc84041f4e69741","VersionId":"1124183949ec436b815799252e731e83"},{"Name":"firmware-hdd-41cdb1c9da-HPG3-5.1.x86_64.rpm","ProductId":"fc2945bc3e5744fea9d120a012546560","VersionId":"26783d282a644af9b665b990904dd324"},{"Name":"firmware-system-u31-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"f5aa8733027b4498a80cd2e690d91986","VersionId":"ec291f98ff8749b2a16d2601fc7723bd"},{"Name":"cp070231.exe","ProductId":"f22e031456d1410688940c3efe38cf1d","VersionId":"94df683fa8b644c6a9273f8868761e88"},{"Name":"firmware-ilo5-3.17-1.1.x86_64.rpm","ProductId":"8aa4f1e30dfc4417885cea85b551314e","VersionId":"28ca4bc4cf0b4a139c2e833b8a3b3822"},{"Name":"cp068765.exe","ProductId":"b61013381e514e74835819b0f29c6165","VersionId":"bf7bdb27b83840859208ee6943062446"},{"Name":"cp067916.exe","ProductId":"b57ffa2f7fe942a89e589fe3043c5ffa","VersionId":"9ec7574dfdf54b5b857e9c488e3c06aa"},{"Name":"cp069142.exe","ProductId":"8384f9a8878649da8d668b07fb30c48e","VersionId":"8167854a7ae74fc0a78e73884f6d9260"},{"Name":"Kioxia_CD8_KACD8ALSHPK2.fwpkg","ProductId":"3e44af8bcf3140b3bef280f7e913e5b4","VersionId":"38bbc6322f054a4b9d684698cc19c086"},{"Name":"firmware-hdd-8f501d6cf1-HPD4-2.1.x86_64.rpm","ProductId":"b271ca95088c47b0b57cf56bd9562a4c","VersionId":"a01b30d9ab32481babdfa599e5fca420"},{"Name":"Seagate_Summit_SUMMITSUSND3.fwpkg","ProductId":"d0bba068f7ca4e978bcc6d2bf9e8abf7","VersionId":"83ab6972351c42d3b0ce1fc4cf3585d6"},{"Name":"firmware-hdd-805abb7e9c_85032G00-1.1_amd64.deb","ProductId":"830142111c0e4cccaca01db3bc2edf65","VersionId":"da602177dce24501861242b15aece4e1"},{"Name":"U47_2.54_01_09_2026.fwpkg","ProductId":"a294766010e4496a9a5cf2711f22fa84","VersionId":"1a0cf8385cb643688cd23408da998bdb"},{"Name":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"2ef4b1fccb0b4e4aa4c8281327ada522","VersionId":"55f1d9ad1e864cc284e50f954f3d60e7"},{"Name":"firmware-hdd-10385ef3e6-HPD2-15.1.x86_64.rpm","ProductId":"1d54c8dcf99741aabe78b8a4e54d84f8","VersionId":"27009a68f379417b83776e4d996a6ca0"},{"Name":"Samsung_PM165X_GPM1653SAMD4.fwpkg","ProductId":"9adece559a5e4fcf8de67cd47aa7d7c7","VersionId":"e4dd77efe5874d5182f4c9320fb8bada"},{"Name":"firmware-hdd-3815d4b024-GPK8-4.1.x86_64.rpm","ProductId":"990fcc25e986467fbdc6e3aae2e41a2c","VersionId":"e10cdbf81fd44dc998fb58d4e8932ad4"},{"Name":"firmware-hdd-cf0b6cabe1_0HPD4-1.1_amd64.deb","ProductId":"b53b7ee55fb34198a842e8fa3306a80a","VersionId":"38eaa15c0df543118380b458ecff2b71"},{"Name":"cp069950.exe","ProductId":"8fe22752c5324386870794853904b4ba","VersionId":"1d990349c7364b459bb0ee658f8604a1"},{"Name":"cp068734.exe","ProductId":"a25f1000baab4c289a20555c0f1143b1","VersionId":"27683fdd56684a358c88bdcb0e19978f"},{"Name":"kmod-ice-2.3.10-1.rhel9u5.x86_64.rpm","ProductId":"a5b53b4bfa36450dafe72d3912e27c73","VersionId":"2ad565dd72f746929e1608de67357a43"},{"Name":"kmod-ice-2.3.10-1.rhel9u6.x86_64.rpm","ProductId":"a5b53b4bfa36450dafe72d3912e27c73","VersionId":"2ad565dd72f746929e1608de67357a43"},{"Name":"cp069767.exe","ProductId":"7f5cc2735e814d67a516e6e72cb03eec","VersionId":"29e86213c3ab4e94b0b54906f7366af0"},{"Name":"firmware-hdd-b1c9eaf74c_0HPDB-1.1_amd64.deb","ProductId":"61738b9f52854162bc00b831995dd260","VersionId":"f3498c7cc8654d6f803ec92295c121d4"},{"Name":"cp069535.exe","ProductId":"4e3802b484324394ada6924af481323b","VersionId":"a752619acd0a44a19a08372d86280f66"},{"Name":"firmware-hdd-ec908c3650_0HPG9-1.1_amd64.deb","ProductId":"4c6271d05e004c45ba29ce1cb206f9a2","VersionId":"ab311def07be48c3927cbde75ea204c6"},{"Name":"cp068636.exe","ProductId":"912bdc2895264227ab4d6d2895102ac1","VersionId":"8bf4346a35984e31809f5fa03188dce7"},{"Name":"cp069011.exe","ProductId":"fd79732b69c747a4ba4278e32ef12a49","VersionId":"299e3fe8b55e4a29be6501b2933e902a"},{"Name":"cp068342.exe","ProductId":"b2dec2e98a4f489c96311517a4bf5571","VersionId":"3bfb1a3d2e2145d79dda4501869de506"},{"Name":"cp069723.exe","ProductId":"8c2329b4625b415f9c19a0c86db985e1","VersionId":"62b2f5fb3af64069a682ab0c56316de2"},{"Name":"firmware-hdd-b04df66fe9_0HPD5-1.1_amd64.deb","ProductId":"f3c8e04f69244d2193f6f4cd088bef7f","VersionId":"e2237bdc820c4da7b911ebe0f454af49"},{"Name":"cp068541.exe","ProductId":"41b0e237fef743bfa73e14fb19e3c9ff","VersionId":"12c7ef0d7cf542ff8965db1d4f300fe8"},{"Name":"firmware-hdd-9ad359dac1_0HPDB-1.1_amd64.deb","ProductId":"9dea06267ae9459899ac2a4c5391b558","VersionId":"b3524861ce434e37a7b785ec0fa88c96"},{"Name":"cp070183.exe","ProductId":"c5181c3bc0654e9db312aa6200639426","VersionId":"fcfe600bff4e40c8ad04598571152acb"},{"Name":"firmware-system-a42-4.00_2026_01_09-1.1.x86_64.rpm","ProductId":"f201f1f45a1041f9819da1901ffe255f","VersionId":"fa32e7a0ba3340949f96f5c34bfbf7d4"},{"Name":"cp070452.exe","ProductId":"8a08f6182dea4f4eb893d0fcf7833007","VersionId":"d92e1c665e8f4e629035cb196f961420"},{"Name":"cp070132.exe","ProductId":"8ec761f6af0748368439ffd510490ba3","VersionId":"3171b3929c8b46819cdb307e27c675d9"},{"Name":"ql_ah_mbi_open_8.65.21_pldm.fwpkg","ProductId":"5c10ef42611f4cada08e038ec64fbce6","VersionId":"bc48d0c6a7274ea890d1070742ae9a44"},{"Name":"DL20ML30Gen10SPS_05.01.05.103.fwpkg","ProductId":"aacf76bfa7674de086e8a84063eadb98","VersionId":"e553de6b27bd43e982e1d4c580b136a3"},{"Name":"CP066752.zip","ProductId":"5829ee37bc994558baa6a98dd52b6154","VersionId":"4e0d725d6b2547bf98a536bf6b6b9692"},{"Name":"libbnxt_re-235.1.164.14-sles15sp7.x86_64.rpm","ProductId":"332a1cff050e45b999d3c0f17ade482b","VersionId":"f1eb364b44104b1681f2888a5aa237ce"},{"Name":"kmod-iavf-4.13.16-1.rhel10u0.x86_64.rpm","ProductId":"2079058db213445cb2b49d341b2df92d","VersionId":"6e9e3c42100e4bec995bca9397e9299d"},{"Name":"cp068740.exe","ProductId":"6b2dbf58581246349103e902007d06c0","VersionId":"129ea91123b74a9c988498381bdcc34d"},{"Name":"cp069731.exe","ProductId":"e0019db6f6e24588a441b6cb4e743087","VersionId":"ff7435a744224d6aac8e96029a9ca56b"},{"Name":"cp068653.exe","ProductId":"5ac3ee90b2184fa9828f960cd9d17840","VersionId":"189d6977f8aa4eb9928f0801d69e8b4d"},{"Name":"smartpqi-kmp-default-2.1.38-022.sles16sp0.x86_64.rpm","ProductId":"9117053fed1245019c94aab3982b0102","VersionId":"3499ad24a1394d098cf83303fba5de87"},{"Name":"tg3-kmp-default-3.139w_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm","ProductId":"8e8482d9e6e6494a8e54ec40143d190a","VersionId":"556f22f571aa44958d24b4b56cbc3bf3"},{"Name":"tg3-kmp-default-3.139w_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm","ProductId":"8e8482d9e6e6494a8e54ec40143d190a","VersionId":"556f22f571aa44958d24b4b56cbc3bf3"},{"Name":"firmware-system-a47-4.00_2026_01_09-1.1.x86_64.rpm","ProductId":"4a7391c65f0b46d485ea7105b1cfb339","VersionId":"175b14f65a5f4b4691a23aab7aee8a9a"},{"Name":"cp066315.zip","ProductId":"ce8ca413963e4458ade3268c0f9831f6","VersionId":"e6307a46904e4adc8214e64498f63d2b"},{"Name":"CP065950.zip","ProductId":"7004592a3bf74fab99a6fe756662ebbc","VersionId":"5cc55e8f72054302a6d1bd6d2b2ec798"},{"Name":"CP069137.zip","ProductId":"64511cd7ad8d42fea109336ca7a083a0","VersionId":"0a78c3c23c29486b936b276fe2c400a5"},{"Name":"CP066006.zip","ProductId":"fbe68804b30c4fe28e13ea472cae5392","VersionId":"cfe31a29a2d64b97b00b6f7494c8b89a"},{"Name":"firmware-d8000_0130-1.1_amd64.deb","ProductId":"942c49f5fada4f3f9198caca6f81e506","VersionId":"d64057659ee048679b20fbd9c6f1638e"},{"Name":"netxtreme2-kmp-default-7.15.25_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"eafab624995d485096ba1119b617b464","VersionId":"f16a344479db4e1e843bbe26ae4d1ca7"},{"Name":"netxtreme2-kmp-default-7.15.25_k6.4.0_150700.51-10.sles15sp7.x86_64.rpm","ProductId":"eafab624995d485096ba1119b617b464","VersionId":"f16a344479db4e1e843bbe26ae4d1ca7"},{"Name":"firmware-d3000_6.00-1.1_amd64.deb","ProductId":"0a4a4367dcbd457bbb50b971046257dd","VersionId":"dd48ed1fa0f74d52b7aa3f70db3029b3"},{"Name":"cp070206.exe","ProductId":"C9113","VersionId":"2e68cf7c5c944e8dac3a1c14e1da06af"},{"Name":"firmware-system-u61-2.52_2026_01_09-1.1.x86_64.rpm","ProductId":"e99fcbdfe7054c0191086c267b0b5462","VersionId":"153a48461ec44b26b13c172bef259525"},{"Name":"cp069007.exe","ProductId":"8ae644bee0c14cc0b7aad5521f061ad1","VersionId":"6f3942ddb3bd4a8da61bc722e1858496"},{"Name":"CP067769.zip","ProductId":"66a1346762c14adc98a81649c4277c93","VersionId":"331ca58137bc41668767a713b6e50f2c"},{"Name":"cp068657.exe","ProductId":"308794285e444711a0eb3833d54eb10e","VersionId":"abfd69e9a7e643a8a89639344b52127e"},{"Name":"CP069043.zip","ProductId":"f61d4171b71b4f16a99210ceeba911f6","VersionId":"bcabba34074641b793c48a6fb84d7bba"},{"Name":"CP067556.zip","ProductId":"b6cb1e645c374b3e92e6a0688121990e","VersionId":"1069d25103ac4267bfca3899f62f706e"},{"Name":"cp067915.exe","ProductId":"b9dda486435f4c78a30de5b1c831c135","VersionId":"f1cd8f46c3014c16bdd1409b73d30b12"},{"Name":"cp068661.exe","ProductId":"4106b2f5d7c1411c95e94d52dff63df7","VersionId":"47d3648625a244c6b991f4dbff7a42fe"},{"Name":"elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"cf36f8009ed4464f93a208bf9c35b47b","VersionId":"cbb0141049c34b0faa1d65ddc5452cec"},{"Name":"MRStorageAdministrator-008.012.052.000-00.x86_64.rpm","ProductId":"8f24173ef2e740d2b110bb710e861366","VersionId":"fc77eeea8c99495787299504a02b364f"},{"Name":"CP067698.zip","ProductId":"cd1eb2802ed24b6aa04d98effb166b0e","VersionId":"e007d4995120489984d46b3e44e87a5d"},{"Name":"firmware-hdd-805abb7e9c-85032G00-13.1.x86_64.rpm","ProductId":"f4d3c3f0b12d4c1da09c3d11188e06cf","VersionId":"25502ba383f94660b9ac0d565f894d75"},{"Name":"firmware-microserverv2gen10plus_me-06.00.03.708-1.1.x86_64.rpm","ProductId":"c046b36cf8a0464e9240313acab20b06","VersionId":"b1a50f66e8d2407b83819179781ca5ac"},{"Name":"firmware-acce-2.0.0-1.1.x86_64.rpm","ProductId":"7be91d25e6cd4a81ae4d61a4439a88bc","VersionId":"2e62e2b243d94aab8c80c1741ef86cca"},{"Name":"firmware-d8000-0130-12.1.x86_64.rpm","ProductId":"a2d50341a55d404a82473ce007636a93","VersionId":"4629c034c3394719aea902485fa33c79"},{"Name":"cp067479.zip","ProductId":"adefe97a484140f28ccdb1e9dfb3903c","VersionId":"30cb9605ee2e4602b7fa1dd2cf29166b"},{"Name":"22_45_1020-R8M41-63001_Ax_header.pldm.fwpkg","ProductId":"a77901ff235c43f18df58616eefb654e","VersionId":"7319fd82a07c4804b3f42bdb8e099c29"},{"Name":"cp069696.exe","ProductId":"0f3487315f10473a903e3c353d754526","VersionId":"eb805e4703474f4d9f67ea754a1dc6f6"},{"Name":"20_43_8002-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","ProductId":"da435657efe64ff1a664870254b46a1c","VersionId":"96fb4f9e200647c5a4c98b1961c00272"},{"Name":"A43_4.00_01_09_2026.fwpkg","ProductId":"bafc8d47aead420a9621e8d49861aa9b","VersionId":"fe035242a1e64422b7c3e5b6741024e6"},{"Name":"cp069163.exe","ProductId":"d626b04e2b74450287a682c2c77ab027","VersionId":"541d779421014e428b8fc35d5d11c1de"},{"Name":"firmware-hdd-8e1e8083c5_0HPG3-1.1_amd64.deb","ProductId":"580943ac4a1c45d88b3e24b6ae5ef825","VersionId":"e4f7516e93954bd293ec9a888ae168c9"},{"Name":"cp068656.exe","ProductId":"3f2f70c223354bc6b59b77123faa8545","VersionId":"06611b50fde44566a65773be616f675b"},{"Name":"cp067936.zip","ProductId":"6b0653271f3e4e3a8e730542d61ffed8","VersionId":"e9ec7ff017e1463a8bde5873dfbb2737"},{"Name":"firmware-system-a46-4.00_2026_01_09-1.1.x86_64.rpm","ProductId":"871bd1fc79994166a0695e4fb3b5fd65","VersionId":"cf0c305631da4bd6a0da1e6b5ce2a9fc"},{"Name":"firmware-system-u38-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"7ebf7b3b32234babb113c6746f09f68e","VersionId":"cec0af2164fe4a3a81dc265ebc4cd6e7"},{"Name":"firmware-nic-bcm-2.42.0-1.1.x86_64.rpm","ProductId":"1d81dab4bd3149b19db9381601c1abce","VersionId":"8759ff6a29bc41ccab329ef71f7b0c75"},{"Name":"20_43_8002-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","ProductId":"e6fc00ad6a3e4c539778e7419a9fafa6","VersionId":"4abbb390a3c34470b4525b8b7d2ab579"},{"Name":"firmware-hdd-7f2a26e6d0_0HPG1-1.1_amd64.deb","ProductId":"29772c9b119b47c898dedcff775e1472","VersionId":"cab36fd5cbdb4bfaa0cea9daf4c1041b"},{"Name":"cp069158.exe","ProductId":"cdfe3840d6074900a4d11b774d3e5307","VersionId":"42c949f4534a41bdaee1312418602ca2"},{"Name":"firmware-system-h10-2.54_2026_01_09-1.1.x86_64.rpm","ProductId":"4549aae264234c4c8ee7e64a5c9b1222","VersionId":"554c1007625b4cde857b6419d955e0ac"},{"Name":"U56_2.54_01_09_2026.fwpkg","ProductId":"b0391b3a14de43ee99f90e7fe9de4040","VersionId":"c3c8a085e4014a89976cff7fd6076365"},{"Name":"cp068747.exe","ProductId":"074cd65cf284444dbd64a63e5f809ff6","VersionId":"2dbde1482fdc4b03bbfab4b3b37a422b"},{"Name":"firmware-fc-emulex-2025.11.01-1.7.x86_64.rpm","ProductId":"ccd2fccdbff94b0ab75d085d46522784","VersionId":"7693db8e77574e03a7405784eee64a2f"},{"Name":"firmware-hdd-8b26d1ef02_0HPD2-1.1_amd64.deb","ProductId":"8783f0c30a1545f88feb3a27a7839584","VersionId":"26642fd9af7a4ff09e86d6b1c1bbfcf0"},{"Name":"cp069670.exe","ProductId":"e485f42530b84989a3373bff82088143","VersionId":"9001e38f8173493b9fb7ad5c3a48876e"},{"Name":"firmware-nic-open-mellanox-eth-mft-1.0.14-1.1.x86_64.rpm","ProductId":"ec5ba4f75ae340e39f8e129f646a9647","VersionId":"4516ab79d8314703aba17c80a84f47ec"},{"Name":"CP068726.zip","ProductId":"79ba405b8c19425aa9a14902b672b652","VersionId":"99db24b0e9774c86837e6bfdad981319"},{"Name":"cp067478.zip","ProductId":"ce9f91a90e53444d84d0e7a4367d6fd4","VersionId":"92f7231dfbbd46198b761e0044113773"},{"Name":"firmware-hdd-d39e7a7e75-HPG1-15.1.x86_64.rpm","ProductId":"c20869f6e72044ccb4d2b142b029a1ef","VersionId":"d7123f9b68d74ac2a66fa30f9bd71127"},{"Name":"firmware-hdd-d4be2aecbb_0HPD6-1.1_amd64.deb","ProductId":"98e23edaa7ef4fdeb2cf62fce8396e6a","VersionId":"9083b3c59cc140e781ee9327885fc355"},{"Name":"cp068652.exe","ProductId":"cd81ec29d7e54f55ab77712a180c1fe2","VersionId":"830635266472425cad538063c1577b28"},{"Name":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1.x86_64.rpm","ProductId":"dcf87aae93de4d649fef4547bffe751a","VersionId":"0e96e30e7e1040e9b9381713936c3994"},{"Name":"elx-lpfc-kmp-default-14.4.731.6_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","ProductId":"7c61cb3283de42b790100730aaa7c9b2","VersionId":"77373931870e4fb8bf35aa740edf2866"},{"Name":"firmware-hdd-fa46c607d6_0HPD5-1.1_amd64.deb","ProductId":"1d674b6248104e069b7fb661a7f5441b","VersionId":"b92bcd26a45f4e4aa5d2b67e8f35310e"},{"Name":"A46_4.00_01_09_2026.fwpkg","ProductId":"17ae190412f049ff80b7f941eb9e3732","VersionId":"3345935dd7614e8880940116edbd1057"},{"Name":"firmware-hdd-e4f147cdd2_0HPG4-1.1_amd64.deb","ProductId":"cf85e5cea71d4be281d746fc27728160","VersionId":"937a1baf30064cb1bae72125e82af735"},{"Name":"cp069634.exe","ProductId":"8bd617958fd64494b0066602dc57ff65","VersionId":"fa5190582aad429fb4ad708a9c44f101"},{"Name":"CP065971.zip","ProductId":"261c2f9a8f584fd69c7ae5c1643322e4","VersionId":"5bda8aab3a0f4794810c9b2b92732953"},{"Name":"CP066010.zip","ProductId":"628a576c95694de3aab72daab877bb47","VersionId":"6025ac4d83194e2c9c1ebd2935c8df60"},{"Name":"cp069551.exe","ProductId":"1607ed48320345de80b2a91bfe782685","VersionId":"b70a0115b54549caa0ab62a22d2d87db"},{"Name":"CP065973.zip","ProductId":"23ed237c56c047b39f75b9977e930a45","VersionId":"442b737a911c4ce88402c62648838ae7"},{"Name":"cp068750.exe","ProductId":"5f5babdc8edb43cda68a851809a46823","VersionId":"20c192b14fdb4fb3a6a567aa634cf151"},{"Name":"firmware-hdd-6fc985bd3b_0GPK8-1.1_amd64.deb","ProductId":"1d44852ea69b4bbc91ed4be4d1a7792a","VersionId":"1e209eb0643448c7807a68cd1e86d10f"},{"Name":"CP065944.zip","ProductId":"0b3bbfed90454334ba3331c2f9efa2ea","VersionId":"8c3ce5786422481ca1e335852104a165"},{"Name":"kmod-hp-iavf-4.13.16-1.rhel9u5.x86_64.rpm","ProductId":"6d5b098230e341e9881e9381bf19ba96","VersionId":"214bcf2b57c04da08ce6776aac488797"},{"Name":"kmod-hp-iavf-4.13.16-1.rhel9u6.x86_64.rpm","ProductId":"6d5b098230e341e9881e9381bf19ba96","VersionId":"214bcf2b57c04da08ce6776aac488797"},{"Name":"firmware-iegen10plus-1.0.0.22-9.1.x86_64.rpm","ProductId":"03c87662bb3a4a57a852807a8f77de3f","VersionId":"b751449de7e3448b90a977acbc3c01e9"},{"Name":"firmware-smartarray-1f19a4a64d_5.15-1.1_amd64.deb","ProductId":"4b83f1a7716845c5a3d89ea69bd8a6a7","VersionId":"56ff4c02b6444232816699a470183894"},{"Name":"HPE_E810_CQDA2_4p90_PLDMoMCTP_80020EF2.fwpkg","ProductId":"f3f8a4081d78499e9a2dd9c8d9fb4059","VersionId":"c1784f3b92234d5d8944742c77db4f74"},{"Name":"kmod-qlgc-qla2xxx-10.02.15.00_k1-1.rhel9u7.x86_64.rpm","ProductId":"62fc8de385854321919207903df8d568","VersionId":"a31aceb185784562a36bd3cdbeea58cf"},{"Name":"amsd-4.5.0-2110.2.rhel9.x86_64.rpm","ProductId":"6e4df08455db4ce3a3b07b6eecea6280","VersionId":"831aaa631b044444bf229e814d8bd866"},{"Name":"kmod-bnxt_en-1.10.3-235.1.164.14.rhel10u0.x86_64.rpm","ProductId":"a529a1b0d8b0405f80457239f0d32b29","VersionId":"8e35585af64849d9a9b92d4cb546c7b9"},{"Name":"cp068751.exe","ProductId":"ae8b95207bc948489c851dd62c16f373","VersionId":"e5d44479dcd241aa80b77c5e9a3eaf67"},{"Name":"firmware-nic-mellanox-eth-only-mft-1.0.9-1.1.x86_64.rpm","ProductId":"35cb34a457a347fd86df4f560cf6cf57","VersionId":"caf4e5f4ae5c4b96b576fa770c695f5c"},{"Name":"cp069564.exe","ProductId":"dcd60b858b6c4ac298dc49b61299aeb5","VersionId":"100ccd3730bb453988f65d8a8d2dacde"},{"Name":"cp070248.exe","ProductId":"2e589cc6a48f40eaa0870785c3351832","VersionId":"29d0c504459a4a78b5391dce5102500c"},{"Name":"firmware-smartarray-f36d4ef431_0.39-1.1_amd64.deb","ProductId":"28da662386ba44b29fd0f050194b057e","VersionId":"96a3a2df5fdd4882ab04e83b1ab5fe31"},{"Name":"cp068345.exe","ProductId":"1174220fe8354722a040071980d1eb37","VersionId":"fac75eb70c924ea69774e71cf8fa763a"},{"Name":"HPE_E810_2CQDA2_O_SEC_4p90_PLDMoMCTP_80020EF7.fwpkg","ProductId":"58e30c6460374d34ab64c2a8547dafe2","VersionId":"d71c77fdf6f747e895937e6e280cbe25"},{"Name":"cp069550.exe","ProductId":"ab1694a2c3b34d68b6e9d41c15960bf5","VersionId":"139342fddb704f7abff074902a8fb7b8"},{"Name":"sut-6.5.0-3.linux.x86_64.rpm","ProductId":"b3a8e7e2c4ea466a9b404955f474449e","VersionId":"1466d379f5f84ee4914865b141c07a38"},{"Name":"CP065932.zip","ProductId":"35452d3049b54455b15816bf1978a61f","VersionId":"be0a1042d0204a86ac4cfc2eeaf6b666"},{"Name":"cp069151.exe","ProductId":"17666522baed46e695f28d4315d6fdb8","VersionId":"2777f6fda48945ed81cea9765028c6c0"},{"Name":"hp-ixgbevf-kmp-default-5.1.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"58259b45dec7469580dfbddb76171768","VersionId":"485902bc894d43778f6106101e7d3c4d"},{"Name":"hp-ixgbevf-kmp-default-5.1.6_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"58259b45dec7469580dfbddb76171768","VersionId":"485902bc894d43778f6106101e7d3c4d"},{"Name":"CP066004.zip","ProductId":"6f1e3dc0362445eba42c38fd34e5d638","VersionId":"f38300f9f29d40558648ce3d9c0e2ab3"},{"Name":"cp069346.exe","ProductId":"01e0939311154208bbd5b8d9e5157a9c","VersionId":"ce76dc9b3af14383b0c03a0be0be0bb7"},{"Name":"firmware-smartarray-7b5e8400dd_1.27-1.1_amd64.deb","ProductId":"6a847a9d6bca429f84558286ffec6636","VersionId":"84fa069df01d4e558127828cc2b6fecb"},{"Name":"Kioxia_CM7_KACM7ALFHPK4.fwpkg","ProductId":"9f1ff08535434ba0ad3d9924079f9908","VersionId":"518ac76b543d46469d9245292ee12137"},{"Name":"A47_4.00_01_09_2026.fwpkg","ProductId":"74593c8509e24398998a42d78a910462","VersionId":"d1c7195cfc1e42d2ab2132f505542218"},{"Name":"CP069136.zip","ProductId":"11f86ddaaa3742028089d7f3e7f71098","VersionId":"cb93a69eaa354131be22ecdff471aeb3"},{"Name":"firmware-hdd-e320db791d-MPK78H5Q-6.1.x86_64.rpm","ProductId":"5b139cd72d0b4c89818f276c3a1dce8c","VersionId":"1070be9bbbed4c4086fa6ad6742ae22a"},{"Name":"cp068980.exe","ProductId":"a8ea930bfde1449ab4444eb61f65be31","VersionId":"b3480297df324a12bff00057bd25edf5"},{"Name":"SKHynix_PE90X0_KPE9010IHPK2.fwpkg","ProductId":"ef1bc7c351c4439cbfa57f557a362e59","VersionId":"ef508d000e044335b7e14985704ba1f8"},{"Name":"CP064261.zip","ProductId":"f68792033b364ab4b274dc849cf93dea","VersionId":"d03f21f7e00b40b4996d662ba82ab674"},{"Name":"storcli-007.3212.0000.0000-1.noarch.rpm","ProductId":"0883e4abd7344c9b834b5e5585107933","VersionId":"d6104339182e406d9e164d67a885c451"},{"Name":"firmware-hdd-ca21e169e2-HPG1-14.1.x86_64.rpm","ProductId":"02a1f5d0f0e244c0b4c2ace636d0f60b","VersionId":"7b3cf9c7563743daa6b562147e8d59c4"},{"Name":"BCM235.1.164.14_BCM957414N4140HC.fwpkg","ProductId":"a4dfe483f7df4c3993a498bb13f08613","VersionId":"06b7d7577bbf4c3cbb07c25bf7795353"},{"Name":"cp069545.exe","ProductId":"9681dd7da3ad4cfa8b9f5d2fa3efb5ac","VersionId":"bc3de517782147afa79bbf057ec34708"},{"Name":"CP065982.zip","ProductId":"8e9f61780275418686c8b0a671e012c9","VersionId":"b140902a90e9402ca1580bc2b9bc489b"},{"Name":"CP065983.zip","ProductId":"3fba85b34f854c9b9b5bb51030ba5e41","VersionId":"22eb5327aa084ebaa74d6463bbe06c9d"},{"Name":"firmware-system-u50-2.54_2026_01_09-1.1.x86_64.rpm","ProductId":"d4e991bf139c45c8a6f5a9b30e1a9d04","VersionId":"ee5fd5e77ca345c49b566fce80d6df80"},{"Name":"firmware-hdd-35fd24601f_0HPD5-1.1_amd64.deb","ProductId":"151904788c644c28a2c281d63b7a3b35","VersionId":"527908168aca403da34cfd18a15ef35a"},{"Name":"cp068622.exe","ProductId":"4ec88340a2ce4a0da239c4051a775bd6","VersionId":"e4aa692ceed2495eac575e38697200dd"},{"Name":"kmod-elx-lpfc-14.4.731.6-1.rhel9u6.x86_64.rpm","ProductId":"e760dc1509734b53830053c8a8b00097","VersionId":"c3c7312c567d4cc79e5681530cda29cb"},{"Name":"26_46_3048-MCX631102AS-ADA_Ax.pldm.fwpkg","ProductId":"b50552ebf09d445294b0b81e162643cf","VersionId":"b6f79883124748f38807582b5faf7f63"},{"Name":"firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1.x86_64.rpm","ProductId":"849be1890758471abae8ed641e7b3fb4","VersionId":"f457b16828314c279f84d52e2451956b"},{"Name":"cp069527.exe","ProductId":"1188e33080924486b998a030d43acf6f","VersionId":"a42e1a033bf148858813a4a46baf61b9"},{"Name":"kmod-hp-ixgbe-6.2.5-1.rhel9u6.x86_64.rpm","ProductId":"b27e4086749b43a09022b1ccf9b6e0c0","VersionId":"fdcef100ed52453cb0ab7e4f96ab96f2"},{"Name":"kmod-hp-ixgbe-6.2.5-1.rhel9u5.x86_64.rpm","ProductId":"b27e4086749b43a09022b1ccf9b6e0c0","VersionId":"fdcef100ed52453cb0ab7e4f96ab96f2"},{"Name":"CP066000.zip","ProductId":"070f2ccb66ec4478ba85a2e3d9712434","VersionId":"d3127bf38a094ef284bcda3b9b102157"},{"Name":"cp070383.exe","ProductId":"570234d74f264fc1985961d91a29c03a","VersionId":"66b90de597c94dbfaf7482bc5137b3f6"},{"Name":"CP068979.zip","ProductId":"2b1131d5128b46ff8528f19d5b030560","VersionId":"1d4aff589dc546f087c7d4ba74ef9546"},{"Name":"cp068736.exe","ProductId":"5d8c4ca5e9ce4b8ab296e754f4544502","VersionId":"98f0ab5aa0074cff977bf2a34841783a"},{"Name":"cp068340.exe","ProductId":"e33bb1d2f7324af98ab1d5f7897ec4b5","VersionId":"5d49a6bb54c845babb67cc7c8c4d0128"},{"Name":"cp068664.exe","ProductId":"c65e02b4990e43eea4fa2402b45960eb","VersionId":"e9dad618e5094f738b2218775c6075d9"},{"Name":"kmod-qlgc-qla2xxx-10.02.15.00_k1-1.rhel9u6.x86_64.rpm","ProductId":"9d355b002f0f45528687c05a8ded7241","VersionId":"d9e0960020f5433494a721ef51723b25"},{"Name":"amsd-4.5.0-2107.2.sles16.x86_64.rpm","ProductId":"68526791858d42b69b174ffed2a35fa0","VersionId":"9199a59d559c451f8beca34fcfa39e63"},{"Name":"cp069525.exe","ProductId":"8f4fd902230c4076905c23b7ab80bfdf","VersionId":"ffcf7ca8115e41f8856490ccfd120cc0"},{"Name":"cp070342.exe","ProductId":"f74d125372264713b4a9d8ebea70260d","VersionId":"50863e760c93433ba9dcb667a5a031db"},{"Name":"CP069153.zip","ProductId":"fe217a349ea5432eb992dea833e5cc7b","VersionId":"73330e456c804f06824b8c077e03ce19"},{"Name":"CP069010.zip","ProductId":"96d916494e7148b08fda3030539ce372","VersionId":"38bb7166f9404eb7986690a259766680"},{"Name":"CP069160.zip","ProductId":"75dd01ca72594b0686b5c281ad30ac2a","VersionId":"e5aee7baddc0495db570044c82ecdb7f"},{"Name":"firmware-hdd-8d68452816-HPD9-2.1.x86_64.rpm","ProductId":"6f10e85c0a8e4d0f99dcb8584f535fd3","VersionId":"8973e5e1313f4302babcdb7c39e7f423"},{"Name":"cp070200.exe","ProductId":"4ecda510f4cf4aef9ac80ad782d1c36e","VersionId":"5d6d42aeaf6647f4b93300a058a01ade"},{"Name":"firmware-hdd-e4f147cdd2-HPG4-6.1.x86_64.rpm","ProductId":"d780ef43938c40d3a6628583fe2200f7","VersionId":"db2860c512e84e70bbb42ca36725ff41"},{"Name":"firmware-hdd-adb3ab8147_0HPD8-1.1_amd64.deb","ProductId":"580a9fa720c34c1ab7b8556a4f1de833","VersionId":"65d63a0ca7d3495faf015cbfa213b973"},{"Name":"U50_2.54_01_09_2026.fwpkg","ProductId":"7fe88b20c8c948e29d704473f3133fee","VersionId":"e344c1b32e984d86bb35e21ac4f1a4ed"},{"Name":"CP066009.zip","ProductId":"b1381f6ec67b40269898593ac27aca95","VersionId":"671351a63ae9400183e592bce3be61ad"},{"Name":"cp069544.exe","ProductId":"2433baff8f4443ed8ddae6e9a115bc4d","VersionId":"a556c13877764198a3876ee835f32a53"},{"Name":"CP069152.zip","ProductId":"b80afd72e0994f04bb439cddf1f507eb","VersionId":"e2749e77cde845dc994c9b2d7d66c688"},{"Name":"CP066971.zip","ProductId":"2fa1597649f243c092f040a8ecf90232","VersionId":"648fd11e12d2405e801501f32dffc3dc"},{"Name":"libbnxt_re-235.1.164.14-rhel9u6.x86_64.rpm","ProductId":"c73603f447664d53b84b56e38b35a86b","VersionId":"4dd9819d2a844736b3709222a082209e"},{"Name":"firmware-hdd-017797f12e_0HPD4-1.1_amd64.deb","ProductId":"71e64c3d009643d19a9590b92132604d","VersionId":"e34198bd888c49899c9a9488120492f8"},{"Name":"cp070130.exe","ProductId":"77057f17d85c42018e33e3454cf6ece5","VersionId":"c80f9df44bb643c7a27894ab5c17cd93"},{"Name":"CP065986.zip","ProductId":"787f189347ac420fbe52f5e6292d569d","VersionId":"4adaf2607e844265be77d76abccb13f8"},{"Name":"bcm235.1.164014.Optimized.fwpkg","ProductId":"8d2bd99747b540d2a364efef8e58a91c","VersionId":"0fae485dae544088963e4af875a8a9c7"},{"Name":"cp066737.zip","ProductId":"7ff6f17e72894f4e8c910355a9fb9992","VersionId":"891f2ffc824a4cc49041d895d19d7c6d"},{"Name":"cp069534.exe","ProductId":"188764648e874fd98523f669c6e5a042","VersionId":"8baf70fa92224ee793e153bff16e6ca2"},{"Name":"firmware-system-h08-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"4e5f478436f1475182a0e382836296e1","VersionId":"5c2b2d8b61d742ef9944ac94c5606fa6"},{"Name":"cp068647.exe","ProductId":"dd83343964ed4806840a86595ee2254d","VersionId":"f2fede41d4c74f11919547b30cd6dbb7"},{"Name":"cp069728.exe","ProductId":"130da7feaa1d444b8b70a759892883b1","VersionId":"20ae32eac4a1401299a8d17a3e777908"},{"Name":"cp066322.exe","ProductId":"ad60a281882240318ac9ec3091a5f1c9","VersionId":"4ad7710b79bf431e8a3a583454a5db1c"},{"Name":"cp069524.exe","ProductId":"dac1034844fb4856950db71b5b2c959d","VersionId":"5a97fd5cd0634cc6ba9d464ec85c11a5"},{"Name":"firmware-hdd-852266afdf_0HPD6-1.1_amd64.deb","ProductId":"a407dd0c97da4a93aefdbd107b2f75e2","VersionId":"aa3fc98efae6465da04e3549f4ed3c53"},{"Name":"kmod-elx-lpfc-14.4.731.6-1.rhel10u0.x86_64.rpm","ProductId":"12aedd0e69a442908a699d2cefb38320","VersionId":"760a93fedc354daeb55a2fc0b59057c8"},{"Name":"cp069002.exe","ProductId":"84f4d8cbba034646b75e0fce6c455870","VersionId":"65dc772cca1e40df9753ff841de74c49"},{"Name":"22_46_3048-MCX623106AS-CDA_Ax.pldm.fwpkg","ProductId":"23c569ea92fb47f091a7a0c891acff72","VersionId":"f8d353a1a83e40f58ab4eb97c686fa11"},{"Name":"cp068642.exe","ProductId":"9c9f3096a89f4cc7b4a9b97b01822036","VersionId":"8a0eab159b4b4e1bba5cf76f4366828e"},{"Name":"cp070173.exe","ProductId":"64242f6035c24947925dbb84f5af8b24","VersionId":"7a4563ae09c54e42ac3664d46857fa00"},{"Name":"WDC_ParisD_WparisdASFD1.fwpkg","ProductId":"29b23e8f7b0d4dbf97ddc41ea0425103","VersionId":"12e10145ad2c40a5aeb104112fcffe11"},{"Name":"cp070302.exe","ProductId":"c3e42591dc7346b48d6b9ae18a9810a3","VersionId":"3b42cc41859d47d4b6091d5d897c2657"},{"Name":"firmware-hdd-7a1edae8e7-HPG1-8.1.x86_64.rpm","ProductId":"41c374eaf1f14df3b6eb451ccf1a1aaf","VersionId":"f8863e8510334a8fb6bd7e4316044cf8"},{"Name":"firmware-hdd-92d876cfea_4ICRHPK3-1.1_amd64.deb","ProductId":"22f47c40d1bf4a1ab067b32f5bab759a","VersionId":"50b939080efa43129643283ca6b4ab95"},{"Name":"cp068732.exe","ProductId":"eb650e36c9b84eb1b7c6c75d7ff3e9f2","VersionId":"5d391774ceff44a2a6b208614f9a29cc"},{"Name":"BCM235.1.164.14_BCM957412N4120HC.fwpkg","ProductId":"80ea6cb0c7d14159a1a37d37866e5b0c","VersionId":"086bfe6521324be8805b9a90ecb4f95c"},{"Name":"cp070255.exe","ProductId":"e90f7f429e824a139d97e1af559547fa","VersionId":"ced6241773ff469f9cf5537770d81c7d"},{"Name":"HPE_UBM2_1.20_F.fwpkg","ProductId":"3b175f364fc14c6da598ff868e4cfb48","VersionId":"03cdf815345f4efd94751eaefd47e77f"},{"Name":"kmod-ixgbevf-5.1.6-1.rhel10u0.x86_64.rpm","ProductId":"2e783bb79a1d489d9f42398711c931ef","VersionId":"08a9c17943ec4bf78d7a098efe80ef09"},{"Name":"cp068735.exe","ProductId":"bba1d0334a5f4b5fbc1a282af5290868","VersionId":"3fd1113df84b4bf58e44e3280cea8190"},{"Name":"firmware-hdd-befd42bd64-HPG3-6.1.x86_64.rpm","ProductId":"8f93dddcb15744aab6bb426d5e84dee8","VersionId":"2a06adfbec30486d8f4a28dfefe3e391"},{"Name":"cp069724.exe","ProductId":"9a74de9c33bb4afeafe66492b230f37e","VersionId":"54d504f6c59f4fa29b42a809d81d8fd5"},{"Name":"firmware-system-u32-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"ff5a3639b5c744a8ac2e4611ce9482ea","VersionId":"32f8ab523245433c8a1063f6d1d5ccce"},{"Name":"firmware-hdd-ef93133161_0HPD4-1.1_amd64.deb","ProductId":"f9dbbe8b7e1e4b98989ec92420b12775","VersionId":"cc3ed153aac14ce49642988e0d6f2151"},{"Name":"20_43_8002-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","ProductId":"3f4d9eceae63421389745abdf06f001a","VersionId":"5ad771f086b3497a8a7a8ebb9ccce819"},{"Name":"cp070009.exe","ProductId":"bc3fe657ed304b17aeeab14dfddb1656","VersionId":"37e2560b0c9446af84c14aebea5d053b"},{"Name":"CP065980.zip","ProductId":"31f49e59526b43cb994f293d4205e9e6","VersionId":"feef26afe3244381aacf3ac21b08abbc"},{"Name":"kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"01cbc1be755b4243b92be8c9339313eb","VersionId":"8f21239f09bb4c239012f26be8a87dca"},{"Name":"mft-4.33.0-169.sles15sp6.x86_64.rpm","ProductId":"01cbc1be755b4243b92be8c9339313eb","VersionId":"8f21239f09bb4c239012f26be8a87dca"},{"Name":"cp068651.exe","ProductId":"f1a885eabd844ec18e0dab540c21f1c8","VersionId":"34f98f1102e24c1dbf193b48205c52da"},{"Name":"firmware-hdd-7f2a26e6d0-HPG1-14.1.x86_64.rpm","ProductId":"d33174a587ab4b3ea4d5e4e22de786d1","VersionId":"9b7922ea3a25464699d43072eb87f8c0"},{"Name":"cp070238.exe","ProductId":"0e95d953f6c341e2ab45544cad6adaa1","VersionId":"66da2d27d8d644f69b1dc1b73c1095f9"},{"Name":"CP065992.zip","ProductId":"a2bc84f793fd4972b6196baf3df85eb6","VersionId":"5268232d10d445a596b065d77b66da67"},{"Name":"firmware-smartarray-f7c07bdbbd-8.00-1.1.x86_64.rpm","ProductId":"02754226ca24415fbdc877dfe47af242","VersionId":"b35660d96a244bb39b5585a5b5af5811"},{"Name":"cp070449.exe","ProductId":"7726a9100f9d46aeb7672151b0d319ea","VersionId":"1208eb584aec4cea897af4d3a34651f1"},{"Name":"firmware-hdd-bdfb8e99d9-HPD9-2.1.x86_64.rpm","ProductId":"73ec3bde4c824e4abd7a12e09eb4bcb4","VersionId":"241ac77ec9144d9c9a5d27ff919c2fbe"},{"Name":"cp068639.exe","ProductId":"e5d8389759aa4832a8475a2ff763f16b","VersionId":"23d8ca08b6234a54bf8d8752132880fd"},{"Name":"26_46_3048-MCX631432AS-ADA_Ax.pldm.fwpkg","ProductId":"27053985f2354572a6633cc6a63bb7ef","VersionId":"fd3fc6991e0a4d6995242fafbf93508c"},{"Name":"cp068634.exe","ProductId":"2a95310f5de64c9fad6c33cfacf5d307","VersionId":"3695033488784f1a95f15765cebc6677"},{"Name":"firmware-hdd-8e1e8083c5-HPG3-6.1.x86_64.rpm","ProductId":"24bbe0adc4dc4c7385b6f5ad6aecf867","VersionId":"426ba3dc2e0c4272b5336f0e1357a237"},{"Name":"A48_4.00_01_09_2026.fwpkg","ProductId":"c91a34b258694c1696514c7b51041b33","VersionId":"9273b95b3b6f437db74e2698ecd875dd"},{"Name":"firmware-system-a41-3.70_2026_01_09-1.1.x86_64.rpm","ProductId":"d152e4f9638d4a6a962a3424ad625ef5","VersionId":"bb06bda69ad1445a94c9714ca5164380"},{"Name":"cp068939.zip","ProductId":"fade5b11c713406a8e9c5f691c073fe5","VersionId":"f8ead878e3794e388b8989f0b30478c9"},{"Name":"ql_hp_ah_mbi_8.65.23_pldm.fwpkg","ProductId":"066920f0b4684f1da260602d0174d2e0","VersionId":"4b658756c8a14d80ba2c6e5ea4f3a675"},{"Name":"firmware-hdd-24384980ec-HPD2-4.1.x86_64.rpm","ProductId":"8d0bd1ce26004a9e8191551757cba42d","VersionId":"87a0067ffcf54b28965bb0d0634585e6"},{"Name":"firmware-hdd-adb3ab8147-HPD8-8.1.x86_64.rpm","ProductId":"6559625804344daab70667e2f1b0b044","VersionId":"e3c7f7487e78456cbb96dab8196735b3"},{"Name":"U34_3.62_01_09_2026.fwpkg","ProductId":"170e9646d84b43c984c43d017aedc665","VersionId":"279f7b3717a44a58bf58d64fb5727df1"},{"Name":"CP064922.zip","ProductId":"1655bc494b334729864d929c38544849","VersionId":"1491d75394fa433089f3444461292a8c"},{"Name":"firmware-dl20gen10plus_me-06.00.03.708-2.1.x86_64.rpm","ProductId":"c165fa12d9644f82b813c7e585ce9181","VersionId":"36f9ee2997194fb68b7825318c47f4d0"},{"Name":"U64_2.52_01_09_2026.fwpkg","ProductId":"4502e15e8e6c48d58b299fb45b3d1658","VersionId":"91809834cfec44b5a2f36639a03638c5"},{"Name":"U40_3.62_01_09_2026.fwpkg","ProductId":"118ba074c4b3495fbd26210e14a17511","VersionId":"b07a7b6a2ce443c1bde9a23a5d440e4c"},{"Name":"CP066008.zip","ProductId":"386eb9df6414454ca63bfe17b21ac760","VersionId":"14ca93ffa5f94a888d3e2e649aaea7a8"},{"Name":"firmware-hdd-a05f29cef3_0HPDD-1.1_amd64.deb","ProductId":"a94c7d3500c34676be3fda4cef325374","VersionId":"6fa9d5eea20747d6b6f8cd01dfded45d"},{"Name":"firmware-iegen10-0.2.3.0-8.1.x86_64.rpm","ProductId":"05f0508175404d989c50e4f9a4e09a23","VersionId":"e91049f03c4649bd991453920d081df9"},{"Name":"CP069006.zip","ProductId":"83f19a40734047f1a91d25f9cd465999","VersionId":"77e1e25b563e457bbff2e0dfa78c3b36"},{"Name":"kmod-elx-lpfc-14.4.731.6-1.rhel9u7.x86_64.rpm","ProductId":"02e2779ea258441c8ba6426a8772f536","VersionId":"db2ccf4425484f7fb600b9bd17c535c7"},{"Name":"Seagate_Cooper_SCOOPRHPESD4.fwpkg","ProductId":"58f3059c65eb403984076353b9f058af","VersionId":"351d50a2bba345ebbd72893c5d1e177f"},{"Name":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","ProductId":"aa9211e645514db69ecc4a92d0863429","VersionId":"fd4644ff6898456b8bf5d3a92e550bfa"},{"Name":"cp069347.exe","ProductId":"3ac61ed209fd49fb908341fa7b77c3ea","VersionId":"bca28cc15a484d30b263b703e9e833ce"},{"Name":"CP065946.zip","ProductId":"65980a419afd45d6b2067bb6166a4282","VersionId":"a0bbf3db79104da6bc975c6db1959f9d"},{"Name":"firmware-hdd-abd133f0de_0HPG1-1.1_amd64.deb","ProductId":"0740887082f84323b1025ff5aaaeefed","VersionId":"7aa582b22781487ead53b5b369c9367e"},{"Name":"cp068745.exe","ProductId":"3f71b29f23c14fcb8f1f4cc9ac53400c","VersionId":"bcfbab82abed4237b56f417784cb3e5b"},{"Name":"cp068746.exe","ProductId":"92d9bf17d9ef471e842a80e42a41ec72","VersionId":"70a95b0733094a948f37a598b20428eb"},{"Name":"firmware-hdd-e320db791d_0MPK78H5Q-1.1_amd64.deb","ProductId":"c797fcf50c574d47a553575e505c1d9d","VersionId":"7ccd917ffc0a40dd8628f9c92b92d3dc"},{"Name":"firmware-system-u37-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"c02f997871554705a1c6e597965673df","VersionId":"e866eae7b1a6455fb288831ac8ca6b55"},{"Name":"mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm","ProductId":"710acbec2a70445381651a2e1f3c55ab","VersionId":"f3969b4898734bd288179cdd2b5d71c0"},{"Name":"mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150700.51-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm","ProductId":"710acbec2a70445381651a2e1f3c55ab","VersionId":"f3969b4898734bd288179cdd2b5d71c0"},{"Name":"cp069350.zip","ProductId":"93312d51d8f7459ba48a2a8cbf6722a2","VersionId":"1decdc7a90514de49ce94757cbae9943"},{"Name":"HPE_NS204i_1.2.14.1025_B.fwpkg","ProductId":"5d636f95f482471a9bd020c928d3b4af","VersionId":"2e00bae1236c4ce986309cc6acf06143"},{"Name":"kmod-hp-ixgbevf-5.1.6-1.rhel9u5.x86_64.rpm","ProductId":"1065be4a2b444fe1b0060c3a91fcbde2","VersionId":"d5bd1b74a5d94cbcba4ce618c60fa4bb"},{"Name":"kmod-hp-ixgbevf-5.1.6-1.rhel9u6.x86_64.rpm","ProductId":"1065be4a2b444fe1b0060c3a91fcbde2","VersionId":"d5bd1b74a5d94cbcba4ce618c60fa4bb"},{"Name":"cp068753.exe","ProductId":"dab6093d4d7545e892501476a1f6d448","VersionId":"cb7c7a062d0d46609b85b13dbdfe7f2b"},{"Name":"cp068643.exe","ProductId":"b4de54a776434c1baf230d968d3bb23f","VersionId":"a8c1c0fb65e04e15a97628a36f6cffd7"},{"Name":"firmware-hdd-5dcf26fa42-HPD3-5.1.x86_64.rpm","ProductId":"896ea0712e9c4853949ccb47860e6c63","VersionId":"7d25ddccca094465af5c279763967303"},{"Name":"cp069596.exe","ProductId":"6522bf51105244bfa55540a1e824854d","VersionId":"abd642129a204ef7a157ea1218dda1b5"},{"Name":"firmware-hdd-852266afdf-HPD6-2.1.x86_64.rpm","ProductId":"5525dd3ac4024adeb1f8ec72b9fd1236","VersionId":"56f020a0165144c8989c5eba4a4a494e"},{"Name":"CP065957.zip","ProductId":"cf7cb50c769b4b00ab89aa81d9fac797","VersionId":"8fe40c9bdbd145d3bc4d739f464f1c54"},{"Name":"firmware-system-u33-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"dea19449209743ffa1d2262e07eafb25","VersionId":"53e91569dc6144d096a30afa1e2949d1"},{"Name":"firmware-system-u44-3.72_2026_01_09-1.1.x86_64.rpm","ProductId":"824707fd6d4844feaef370452b0a3a3e","VersionId":"f8380e9008f14be3bdc087fcab3f2bc6"},{"Name":"firmware-system-u56-2.54_2026_01_09-1.1.x86_64.rpm","ProductId":"d04d5f721c2f4e7798db0b91a4b31687","VersionId":"2964a3f83f234573bd7d3a911ea34f27"},{"Name":"cp069547.exe","ProductId":"000bfbde35e84381b78976b2c1748662","VersionId":"778fddd39d4443aebd4b4aca654853c6"},{"Name":"firmware-hdd-5dcf26fa42_0HPD3-1.1_amd64.deb","ProductId":"6e2efe0e417448ccaa6cfbf61d773824","VersionId":"7827731f43134612b48fb4feededfd7f"},{"Name":"IEGen10Plus_1.0.0.22.fwpkg","ProductId":"4c108242693848129dadc44c03c82865","VersionId":"5ba2fe62306d406aae00e2995213020e"},{"Name":"cp070214.exe","ProductId":"169b01f1c4c245bc854a8424af9a5f85","VersionId":"a1be94b4e77745e5bc05bd971321ac2d"},{"Name":"firmware-disk-enclosure_5.04-1.1_amd64.deb","ProductId":"12c818024cd141bdb20ae5471187f1ac","VersionId":"9b4e8f87360f40ff80ae35f17c185313"},{"Name":"firmware-hdd-d4be2aecbb-HPD6-2.1.x86_64.rpm","ProductId":"b9b10cbec6a7489cae77c802c13728a1","VersionId":"c975c71029334580b2c010de2535eb50"},{"Name":"firmware-hdd-82894b9e0a-HPG1-14.1.x86_64.rpm","ProductId":"d7cf155e76584b1f8fb8e3c7c222c90d","VersionId":"4f9966fcba4646cfb18939f7e10db7d5"},{"Name":"HPE_E810_XXVDA4_FH_4p90_PLDMoMCTP_80020F02.fwpkg","ProductId":"955cffa0d4fe4b76923c0ea7afeca0bf","VersionId":"f89af3c7e94d48c4ad6a028e8aecd58d"},{"Name":"U45_3.62_01_09_2026.fwpkg","ProductId":"4bdcb7d3fc5c4d14af793003b89e365b","VersionId":"7229044bddab498fab907fd3e4eb99f7"},{"Name":"firmware-spsgen10-04.01.05.201-1.1.x86_64.rpm","ProductId":"84d998355c4f4bc6997437e9a6c61fba","VersionId":"b543bb6e4f5c49269fa389331223bc64"},{"Name":"cp068641.exe","ProductId":"ab6756bde612475998d62d4bbb8717ff","VersionId":"244a6149e7704ded8c87c64b7bae5bbe"},{"Name":"Micron_5400_M5400ALLHPG1.fwpkg","ProductId":"6792e601e784404b8b27e1297a68223e","VersionId":"02859ac29430461593ee92cdbde4dc9b"},{"Name":"BCM235.1.164.14_BCM957504-N425H.fwpkg","ProductId":"3d28404b009047cd9c6ade47efd24ca6","VersionId":"5adaba69e9b54483b04e405655ff608f"},{"Name":"firmware-smartarray-98373e8f27_8.00-1.1_amd64.deb","ProductId":"5b5ee0e363994b83af6394dce2b49314","VersionId":"2c9a46f86d4b4eea8739911693777d2f"},{"Name":"cp069580.exe","ProductId":"ffc5db5b28504df99cd08b4bf08ccc7d","VersionId":"c974efff3c5945fb8a834885625f2b03"},{"Name":"cp070366.exe","ProductId":"3702e2a6624243b4a85fa9ca1f4c0ce2","VersionId":"9ab6d5db1c064de98baa332c8c5159a1"},{"Name":"SKHynix_PE90X0_KPE9010SHPK2.fwpkg","ProductId":"7e0050d7cc724a879a45bb605213e3c8","VersionId":"4924d8e0104a4e96a2206473e4ce8b62"},{"Name":"cp066304.exe","ProductId":"8085229a62d8443d85751340431d38d5","VersionId":"19d55aa412b443249ba2db4f499373a0"},{"Name":"firmware-d6020_2.74-1.1_amd64.deb","ProductId":"251bfe38793342929fa427f7b456f043","VersionId":"bf61ca3df1ff44339d6a98ee4135df75"},{"Name":"firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1.x86_64.rpm","ProductId":"17cb0fd9f2dc47bb8aba197c6f346c61","VersionId":"467ada0499c54be9b337386ee64ba5b4"},{"Name":"CP067532.zip","ProductId":"f7d7f54393d44f66845199e26d4e5900","VersionId":"7adc9cc7a77a4a5e9b5f8a78c7be6f34"},{"Name":"kmod-i40e-2.28.10-1.rhel10u0.x86_64.rpm","ProductId":"8d934ba033f1419491e76cc92dd89795","VersionId":"d7a7462c5a834d379eaf5c5dc51cbacd"},{"Name":"ACCE_2.0.0s.fwpkg","ProductId":"74ae203907f144b792d71fd805a36304","VersionId":"18f5df56c9374d078ab9c46ec4c9d7c4"},{"Name":"U41_3.62_01_09_2026.fwpkg","ProductId":"2b44e5307a9948769c51d6ac1f276915","VersionId":"b9f7911ef9fe42d099ee0e9a9c97c065"},{"Name":"cp068738.exe","ProductId":"5e23a12643374784bca02e8442853ff7","VersionId":"bb3daea065d04dc191baa120bf1a989a"},{"Name":"U33_3.62_01_09_2026.fwpkg","ProductId":"972a94402aa14188aa7633893c7137b6","VersionId":"19bef68d6a9e47208bd48261b3bd5e82"},{"Name":"firmware-microservergen10plussps-05.01.05.103-1.1.x86_64.rpm","ProductId":"667c48761fdd439199126de11a3666a8","VersionId":"fd0baef48822461c917023c73eb03c27"},{"Name":"firmware-hdd-b1c9eaf74c-HPDB-3.1.x86_64.rpm","ProductId":"9955e8989d3a49ccb377a1c01a7b8a6c","VersionId":"a2bbb424bfdf4cb1a0025efc3d083fc5"},{"Name":"CP065943.zip","ProductId":"001e7fbaf67f420ebcb746aae6b4aee2","VersionId":"40e0ce11db3743dc8166e4a30a532fbc"},{"Name":"lsi-megaraid_sas-kmp-default-07.732.03.00_sles15sp5-1.x86_64.rpm","ProductId":"5aad4922b5f54198b1d9a8e400dcfdda","VersionId":"eb9d8f4ee651453db70f578c42bcca1a"},{"Name":"lsi-megaraid_sas-kmp-default-07.732.03.00_sles15sp6-1.x86_64.rpm","ProductId":"5aad4922b5f54198b1d9a8e400dcfdda","VersionId":"eb9d8f4ee651453db70f578c42bcca1a"},{"Name":"cp069997.exe","ProductId":"7f5cc2735e814d67a516e6e72cb03eec","VersionId":"c523e081ab344bc4b4bc9d5686ff0090"},{"Name":"cp068744.exe","ProductId":"4fd1e8e4a27347cd8d83d1e63d9eb38e","VersionId":"6f7b50d5341b4904868164eb9b923007"},{"Name":"cp068139.exe","ProductId":"e9a54d5b255e4c18936eebffaaff1ccf","VersionId":"613927fcc48e44a1b8df9d2bbdf64f7b"},{"Name":"cp068764.exe","ProductId":"057a33153b064c9280dd7da9d3d5a47a","VersionId":"5388d296fb844a3388089e9558420c7a"},{"Name":"CP066013.zip","ProductId":"1cadb74f384743de9dfa8d9d6bc9f7b5","VersionId":"4d7a555d818942488b362fa21fb30dcf"},{"Name":"cp069548.exe","ProductId":"ad3fba5acbb54355b6ab78730e8d2635","VersionId":"4c184ffadc0949299bd3d8afade1e443"},{"Name":"BCM235.1.164.14_BCM957504-P425H.fwpkg","ProductId":"43699ba116594728bcf30612b7c6f5f5","VersionId":"68e09648e9764dac9d7aab181e14de5b"},{"Name":"cp069671.exe","ProductId":"a83500e26a4d4bb89a4eb5821b7b2ca6","VersionId":"77c0abf6e6e340938e331cc9e83e5a7f"},{"Name":"firmware-hdd-cfd7436fcc-HPD4-5.1.x86_64.rpm","ProductId":"6cc89934ad1740b582b096e05315f04a","VersionId":"07622a2605684dfc8bb07322b6903c83"},{"Name":"CP067701.zip","ProductId":"423cc31f15944616b9452d63683a53fd","VersionId":"a28746b429054472b94b13e27c3d717e"},{"Name":"firmware-hdd-4fbb6d96e5-HPG3-2.1.x86_64.rpm","ProductId":"f18fb22c5eab4952b3cc28771ba83857","VersionId":"6022262f43ce41b4a042d38bdece9fcf"},{"Name":"cp070092.exe","ProductId":"a3ac88993616476a8dcf9b3fac5ea67c","VersionId":"e703974c87ff44f7806534339a848d80"},{"Name":"firmware-hdd-035a863453_0HPK5-1.1_amd64.deb","ProductId":"75fceb5f9b96474d8e651b3560059cbc","VersionId":"010ea8e4097f4b7b9150aa174141a877"},{"Name":"cp068940.zip","ProductId":"eea0fcde2dfe4c0ebeb9ed47ea130474","VersionId":"e7138154c03743fcb5a6b72d23bcf93e"},{"Name":"cp068341.exe","ProductId":"6d1e58e8f89340958bf7818046e9b7c7","VersionId":"5e4add36c4a843b6ac139031c04abfe0"},{"Name":"cp070340.exe","ProductId":"d00882018d64492aa4a5bc81f394c4dc","VersionId":"0b5f34e8f48c46cbaf7095b45694d07e"},{"Name":"firmware-d6020-2.74-24.1.x86_64.rpm","ProductId":"ce7e63b5ed004965a0bc6af06ca584ef","VersionId":"ea88112c3acc420f98c7c51a25243bf2"},{"Name":"cp069555.exe","ProductId":"7a409aa1e5444a57b8b10f884c98ae5f","VersionId":"6d1aec5f11a746129491eab02c7b6005"},{"Name":"firmware-hdd-c566d63ca0-HPG7-6.1.x86_64.rpm","ProductId":"c6a4f7a1c0f14173802a4263b3ee7551","VersionId":"7ad7b70347e749eb8fa34cb98fa66144"},{"Name":"cp068739.exe","ProductId":"968a9e036afd4092af43608fa1a5a87c","VersionId":"03a98050888847a781c6cde05e1c2e53"},{"Name":"cp069517.exe","ProductId":"87793aff72a54849a327ce026784372d","VersionId":"03c3b9c44d5a47e2909fe84d5fe897b1"},{"Name":"cp067914.exe","ProductId":"e79fad26938d4b788f99ac1b9d5aa529","VersionId":"5bd325460cd446faaf9c162a70f2502d"},{"Name":"Toshiba_MG08Air_TAMG08ADAnG3.fwpkg","ProductId":"9797527c9a7541debadf0b96aae4c9b3","VersionId":"9077ed7856b1465a8395a8ce4b5e9a97"},{"Name":"CP065947.zip","ProductId":"2232e2b621a84f55a544f2a4ed765213","VersionId":"d9ce784d3c6446d0a0b58f1fc7bafd70"},{"Name":"cp068761.exe","ProductId":"0a96bc740aee4364b774edfa452ca9a4","VersionId":"636289ed1ad14379824d9cf5cad217d1"},{"Name":"CP066005.zip","ProductId":"4aaa1b96312a4790820f2c40ac3eb0e7","VersionId":"accf85e27715420fa50c2afc082f49f0"},{"Name":"cp069557.exe","ProductId":"e951bbca527f4f9f8a089c23c99574fe","VersionId":"1156f09e64bb44e8a0ac79c721f3e0ba"},{"Name":"cp069607.exe","ProductId":"b81956d2c370432aad5ffc0ea6fc40b3","VersionId":"7bdaa82f3b0243c79e8496b11331da87"},{"Name":"firmware-hdd-c993b31232-HPG6-7.1.x86_64.rpm","ProductId":"87b9a1c22150406cbf61d6b300753282","VersionId":"b55a0487e34c45578e26e301d0a3bc62"},{"Name":"MRStorageAdministrator-008.012.052.000-00.rhel10.x86_64.rpm","ProductId":"3013cefa4fe14260a6f6811796f9b1c0","VersionId":"497253d10cf34662af36bb1d5f1e2596"},{"Name":"SKHynix_PE81X0_KPE81X0AHPK2.fwpkg","ProductId":"b902adf94cea4a0abb9a86aae94c9318","VersionId":"b3ac2dd86a7d4e9aa3340410288c5fcb"},{"Name":"ssa-6.60-8.0.x86_64.rpm","ProductId":"39676e9bd8d74e11b8837e3f6ebabd5c","VersionId":"50cd52f793c142a59934e609300224e8"},{"Name":"firmware-hdd-b04df66fe9-HPD5-2.1.x86_64.rpm","ProductId":"0e486c09859842e29ba327f60bd15f9a","VersionId":"4e33cb3609b14b61a246f9ddee0de109"},{"Name":"kmod-tg3-3.139w-1.rhel9u6.x86_64.rpm","ProductId":"dcff0c4699e341cf85f18eb94d85147c","VersionId":"5c2ad4196c7e42169f6d89cfef5629c4"},{"Name":"firmware-hdd-bdfb8e99d9_0HPD9-1.1_amd64.deb","ProductId":"0bb28a52c60e4e09a0da1e6ee82945ae","VersionId":"880ffde7fc6e496fa172c745e9aca5e6"},{"Name":"firmware-d3000-6.00-11.1.x86_64.rpm","ProductId":"de51682518bb48a2bb985003f8a8df4e","VersionId":"ed7288d4d67d44ae9e19be9b0c12c49a"},{"Name":"Toshiba_MG08Air_TAMG08SDAnD3.fwpkg","ProductId":"66cb80b1d5d040ff8edbcf313b0e2f9d","VersionId":"cb947df2b7494b02a1ae11bb036e5d53"},{"Name":"CP065925.zip","ProductId":"a5e366733eda432d8665f3d8aaa40d56","VersionId":"0d29c281641d41adbcbc3c3426d12e2a"},{"Name":"firmware-hdd-c566d63ca0_0HPG7-1.1_amd64.deb","ProductId":"c31f4b9416db481caaf570f911d5ccd1","VersionId":"71f5230eb7214932998d51f4e9547388"},{"Name":"CP065976.zip","ProductId":"865064fe88324b7ea65c940d300f10de","VersionId":"2e40f73a1fb54c0abb55aa2da3f59574"},{"Name":"cp069736.exe","ProductId":"f74d68169f04405fb74a2820e48df6f5","VersionId":"bce54ec69c3c4680beca7054654ab9bd"},{"Name":"amsd_4.5.0-2107.3-ubuntu22_amd64.deb","ProductId":"41fa8420de8d497db38df0b5cd7ea429","VersionId":"da2b5014ad074a43bfd210b806e7c68d"},{"Name":"firmware-hdd-a27c95663d_0HPK6-1.1_amd64.deb","ProductId":"14d9773880e140e2bf92c4c4e7a389e3","VersionId":"55d35d7690074d37813f0a6d3ab4980f"},{"Name":"sut-6.5.0-11_amd64.deb","ProductId":"d32e3e2cf68a47998f06cb81ab591bd1","VersionId":"c6c1c6da68cd41cb80b608d75e757a14"},{"Name":"HPE_SR_Gen10_8.00_A.fwpkg","ProductId":"3d51e7d6b8674f16bd8f67bee278e11a","VersionId":"c1a1e73eca0649aba8389a70d7e7b502"},{"Name":"cp068733.exe","ProductId":"17203fd912204cbc96571639dbe02ea0","VersionId":"f4ad092bde7c4e34aa17c38fe542fafe"},{"Name":"firmware-hdd-1a541ed00d-GPK6-4.1.x86_64.rpm","ProductId":"e4dd84a160cc43f1b620391e92c1a737","VersionId":"f99825a1487a46a4b05ef9db9bb64e41"},{"Name":"CP067533.zip","ProductId":"486d4489346f4ec8a160ad4ef3c94f99","VersionId":"8ac70dfd510f496e8d1da7ee6c513ed2"},{"Name":"cp069537.exe","ProductId":"283d84a861d348648dca86da7b4218bd","VersionId":"6b655bce70f34c5c82e7ea5b4d91807d"},{"Name":"cp069001.exe","ProductId":"b9a8e50fea15459f9f236f2538fb4a07","VersionId":"87e159a8c516465fbacbe88e8ad509a5"},{"Name":"Samsung_PM9A3_GPM9A3SAHPK6.fwpkg","ProductId":"ff59337dd3ff4f44928eba3219e493a5","VersionId":"46c24384109040aea7a6064e47696122"},{"Name":"firmware-hdd-8a0371a425-HPDC-3.1.x86_64.rpm","ProductId":"aa62b707fef04bb99492053e558daffb","VersionId":"32c19a99dc72438aa00618642c71a953"},{"Name":"20_43_8002-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","ProductId":"cca7377cd12644cab41f5bd7e94cc2bd","VersionId":"a9a7a4d74eaf4a169b6449cbfb4219fd"},{"Name":"cp068621.exe","ProductId":"01713b1febed4cc9a463023eeb2cf6ee","VersionId":"97f9bd5cfe0948f8812fc1eb5af3e9c3"},{"Name":"U31_3.62_01_09_2026.fwpkg","ProductId":"4de9a363a422456faca983d193ca352a","VersionId":"bbacaed717884551acb7bedfe36c0270"},{"Name":"CP064334.zip","ProductId":"03d55b6f216746b88ddef311b0a8c1f9","VersionId":"bd85de99f5db486e935b9e5b89d776e7"},{"Name":"libbnxt_re-235.1.164.14-rhel10u0.x86_64.rpm","ProductId":"c94878ce1a3442eca368e62460770912","VersionId":"a4baff443cfe4f1fb1bd88340daf8418"},{"Name":"U37_3.62_01_09_2026.fwpkg","ProductId":"644b370c36714c6490fce699ffce22e9","VersionId":"bb7dac35a0864d96aad69f3db362161f"},{"Name":"cp069193.zip","ProductId":"5588a72e9c0d4878a499b54f0c18241c","VersionId":"1fa5308a64884136b0383a530f371780"},{"Name":"cp059844.zip","ProductId":"ce8ca413963e4458ade3268c0f9831f6","VersionId":"8921e49bda05419ca6182da700bed3ce"},{"Name":"firmware-nic-i210-nic-1.2877-2.1.x86_64.rpm","ProductId":"c1dd5be659f944a486917246089b40e7","VersionId":"fca448f909e941b281ceb598e7fbc8e7"},{"Name":"cp069726.exe","ProductId":"2ea9059fa42b417a890b2c9927375976","VersionId":"154a444b0711470cab8f62e39aab2ac8"},{"Name":"cp069558.exe","ProductId":"624ecf606d7d4d2c94cae219a5491b9e","VersionId":"1b5e6b3378d6409db3052ab56c33f4bc"},{"Name":"A40_3.70_01_09_2026.fwpkg","ProductId":"6f77f9ef4381482fb9f00a79ce325ab3","VersionId":"1ed83aa415d449a2baa8b55ddc25ad32"},{"Name":"kmod-smartpqi-2.1.38-022.rhel9u6.x86_64.rpm","ProductId":"3d8cb748df644cf3a26ed91efafffb67","VersionId":"3ba8955d2eee4602a11446ec07e9a45c"},{"Name":"BCM235.1.164.14_BCM957416N4160HC.fwpkg","ProductId":"7a201554eb654a4fa5bf0b9e23666148","VersionId":"7e79add644b5423b8f41566c6afb0364"},{"Name":"cp068635.exe","ProductId":"15c5494e659e4865b78e60077bae7860","VersionId":"2209d7eaa57a4b1d8bc62287415a7ba6"},{"Name":"Kioxia_PM7_KAPM7ALFHPD3.fwpkg","ProductId":"fcbfe734454648628f4d8c3848d7db3e","VersionId":"cfb3c1b576564b7fafa4c9bdcc52cffb"},{"Name":"firmware-hdd-abd133f0de-HPG1-6.1.x86_64.rpm","ProductId":"33179a0f0a644a26bd07818fb3f2db4e","VersionId":"bdb052e5bc314474ac40768eebf83bce"},{"Name":"hp-igb-kmp-default-6.19.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"a162b7594d8d4a02bf2f3f7d9fe2609d","VersionId":"54df75fd199f48b4b8c9a20d15c0f96b"},{"Name":"hp-igb-kmp-default-6.19.4_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"a162b7594d8d4a02bf2f3f7d9fe2609d","VersionId":"54df75fd199f48b4b8c9a20d15c0f96b"},{"Name":"Samsung_PM9A3_GPM9A3SAHPK4.fwpkg","ProductId":"3d4b3948a2e7454589365f36eee4d988","VersionId":"3f52ab4febe74549a2c97fc625b32d8c"},{"Name":"CP065949.zip","ProductId":"dc0fcbf999ba4988aa8b4eae8e8c9889","VersionId":"3b34a42dbd6f4c9aa3887be86849e669"},{"Name":"cp068743.exe","ProductId":"0d61334622ba44aeb0c163514d9f57b9","VersionId":"98e732bf3fe24672901b485ba22c9a13"},{"Name":"firmware-system-u47-2.54_2026_01_09-1.1.x86_64.rpm","ProductId":"e9a45a84fc5a4ae9bee13ee0419530ca","VersionId":"acc31e0904044ebaafbcbb910ef6f583"},{"Name":"BCM235.1.164.14_BCM957412A4121HC.fwpkg","ProductId":"41b320ad66f042c0996f23c6087a171e","VersionId":"872cf7c02e014e298e162243edcff4ef"},{"Name":"22_46_3048-MCX623105AS-VDA_Ax.pldm.fwpkg","ProductId":"f5b93810cc2347bb802707c26e414376","VersionId":"f5f2b713518d40dc9d3253b3376a2493"},{"Name":"cp068663.exe","ProductId":"05aa24e5db0c41fc91f79deb60685a31","VersionId":"cc4e3aa900dc4921bb4b6a57ca7ae1de"},{"Name":"cp068763.exe","ProductId":"d09d3bc174174ab69b229c1370a5ce48","VersionId":"e186208a59f74883a23b4da1fb8e4c79"},{"Name":"HPE_E810_CQDA2_OCP_4p90_NCSIwPLDMoMCTP_80020EF8.fwpkg","ProductId":"dc41774861a945f28d388059e656b2ca","VersionId":"6cc7727b8c274fa286c8994ac74f96a5"},{"Name":"cp068650.exe","ProductId":"139d2679780d42b2a020c2a6176ac11b","VersionId":"24c1872edd3c444aab7090b24fb77669"},{"Name":"cp068540.exe","ProductId":"ed7a5d4d2f9c4a55ba7dea78369f1389","VersionId":"8e14684cfcb5422a81e71f5516719a9d"},{"Name":"SPSGen10_04.01.05.201.fwpkg","ProductId":"c4ff2ade728c42bfb931931df173daf9","VersionId":"55b6b49088e34c1484eb0eba7e0d05ce"},{"Name":"firmware-hdd-ae6b41e855-HPD8-8.1.x86_64.rpm","ProductId":"f66d2f40fe3b49a2ae22ce155e429f5c","VersionId":"582f979e397949ae897a999f648304c6"},{"Name":"cp070013.exe","ProductId":"33474bdb31ec42199bc00637b81a4d15","VersionId":"8b87310ce1514fe895401d1f8be7e648"},{"Name":"cp068343.exe","ProductId":"e6bb5c297d78402ab079f188773b5efc","VersionId":"4fedece91cda4c77a4733cae02ce9f28"},{"Name":"cp070161.exe","ProductId":"a6fc6d419cd14563aeefb1d3f50c589e","VersionId":"9698d7ba9b81461984806784b50fb774"},{"Name":"cp070339.exe","ProductId":"f25420df1f7142d3a5eccbf213f27251","VersionId":"b4076ef4dc364ac983a17039f86029bb"},{"Name":"firmware-hdd-18e328f036-HPG8-6.1.x86_64.rpm","ProductId":"862d36dd920c478ca6dcfdb5f392893a","VersionId":"4a2cf298e2444835a79f0b2da8621f47"},{"Name":"firmware-hdd-cfd7436fcc_0HPD4-1.1_amd64.deb","ProductId":"0c7b64360b5c406b8354ad889f429454","VersionId":"fec44508fdf14033bb495fbe34b33b95"},{"Name":"firmware-hdd-24fe569b72_0HPD6-1.1_amd64.deb","ProductId":"22b7710ad6de471aa3aeacbb94b82c36","VersionId":"7b4446ea493f4ed5a55d691a1fa39c00"},{"Name":"cp070261.exe","ProductId":"009bd5d739814a67a018565d835c45f1","VersionId":"d36e2c20c72a4e26b6576799ed18838d"},{"Name":"cp069012.exe","ProductId":"b8bfd68496a643cdaece510776fb4ad2","VersionId":"3119d5cadfcc43c7ad4f3bffb49d7fa9"},{"Name":"cp069530.exe","ProductId":"e774fea9b642407a9f2687df296d352e","VersionId":"31eca7f4f32245f785d0042d0d3c6483"},{"Name":"cp066052.zip","ProductId":"43151427676f44dcaced68356cf6359c","VersionId":"91eedfc8544c413bbd1e5e7e2f1c20f9"},{"Name":"firmware-hdd-2c27a7a9a4-HPD2-10.1.x86_64.rpm","ProductId":"188f54d508794fafbb14f21866a0ffb5","VersionId":"018279bc0bb148e6a910474b45a16287"},{"Name":"firmware-hdd-42aff4675b-HPD5-2.1.x86_64.rpm","ProductId":"74085bfad3ea4badb1e5c0235f47c1ea","VersionId":"1acfb6855d7e460f8e0c563239e759a9"},{"Name":"firmware-smartarray-1f19a4a64d-5.15-6.1.x86_64.rpm","ProductId":"799e6d2dd6574724a67dc3ea392d2873","VersionId":"00fabe6608db428a9aa80c4965341932"},{"Name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1.x86_64.rpm","ProductId":"f148b53c7b96447699a0d01706827644","VersionId":"77417865ef114c4eb255adbb2e05a6c5"},{"Name":"firmware-hdd-c993b31232_0HPG6-1.1_amd64.deb","ProductId":"24db3c54a571487f8640586ecf4c8ce6","VersionId":"27dc2d8802b34bdfb4962861fd18ef2f"},{"Name":"cp069640.exe","ProductId":"348f4fc22c0c4f64b2e050cebccb4347","VersionId":"d2f74bf1d1cf4b6db112111fb7a8ba24"},{"Name":"Toshiba_MG08Air_TAMG08ADAeG3.fwpkg","ProductId":"95cd675c9c4947eda03bc921bfff84c3","VersionId":"22b25cb7056247fca6f226ad387ab8a6"},{"Name":"cp068640.exe","ProductId":"8a01a8f2913f46979fa6206b3faeb0eb","VersionId":"058d8510e4c84af39df1c07ce8b9aed5"},{"Name":"cp068757.exe","ProductId":"0c95f7c054f047b69fbfe7c93264a982","VersionId":"76ebd18092bc4839b75f22e8669eb8cc"},{"Name":"CP065984.zip","ProductId":"6a808075e9fa4bc19e7d11fd17511784","VersionId":"85cbb20de5d1424bacf3b788a8ce9163"},{"Name":"firmware-hdd-8f501d6cf1_0HPD4-1.1_amd64.deb","ProductId":"b5e0206ca4e94cf29c84aaeea6edefa1","VersionId":"a738a86f08dd4a2cb13d6a325c7c2409"},{"Name":"cp068742.exe","ProductId":"96853662d13b4def814a5c153a747271","VersionId":"4df2d8b6de9b405dab609becc2588452"},{"Name":"cp068754.exe","ProductId":"3d1400a6e0204fb498134f7e6e3f374a","VersionId":"9dc1ac030cb645d690837655164b9aea"},{"Name":"firmware-hdd-ae6b41e855_0HPD8-1.1_amd64.deb","ProductId":"106244d003374fa49cfd57be5dd5767c","VersionId":"580ab6d3564a4a7aa4bf1fd841b81106"},{"Name":"cp069562.exe","ProductId":"88920b6128524213bc79e665d9b3a53b","VersionId":"4cf57e3d1f7b41a89f2a4e1fbd4d11fb"},{"Name":"firmware-hdd-10385ef3e6_0HPD2-1.1_amd64.deb","ProductId":"1b34555075d144b0bde6e5495e920e7c","VersionId":"ddcb3a45198f44f5b1a653d1e818b11d"},{"Name":"firmware-hdd-87b796d9ae-HPD4-5.1.x86_64.rpm","ProductId":"630e644160fa42ef980745ef1697fa39","VersionId":"ea370f6467884df19200238f71a7c251"},{"Name":"CP068324.zip","ProductId":"bd2780f798b64cefbb3916c847ffd755","VersionId":"353b02f3101d47b4ae035de7c8327a0a"},{"Name":"firmware-hdd-492a9952f6_0HPG5-1.1_amd64.deb","ProductId":"1fab72b09ffc46b88aa5f81c9be3d475","VersionId":"f41a767438d14f2893b0069a9803a423"},{"Name":"U32_3.62_01_09_2026.fwpkg","ProductId":"7db6f792355b49a58fc4f82d6bbbdd99","VersionId":"ed13b4c84eff4d909a8f158d12fd9aed"},{"Name":"cp068938.zip","ProductId":"6ac4c1fb52734dc69d27fd9966ff92b4","VersionId":"c0950df8df16430ba7d6622d2278741a"},{"Name":"hp-i40e-kmp-default-2.28.10_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"7204c0f5c514445a87ae5a6c742f6a37","VersionId":"929ac9cf30c840959bcc9f2a17f38195"},{"Name":"hp-i40e-kmp-default-2.28.10_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"7204c0f5c514445a87ae5a6c742f6a37","VersionId":"929ac9cf30c840959bcc9f2a17f38195"},{"Name":"kmod-ixgbe-6.2.5-1.rhel10u0.x86_64.rpm","ProductId":"da9ff49af6c74b6d969bca700eb095c0","VersionId":"0b5dc9efc4604d2395d6023c2563b518"},{"Name":"cp066257.zip","ProductId":"6847395ba4ef4b018475096e40729a70","VersionId":"54ee325a61e84639be6b288cef1e89ee"},{"Name":"firmware-hdd-a05f29cef3-HPDD-4.1.x86_64.rpm","ProductId":"365d207e25654d61b3829f731965d204","VersionId":"4d0081a2928643a98e1eabd433b2d539"},{"Name":"cp070357.exe","ProductId":"1bc921f76f2d48759522424a4aff4914","VersionId":"095dfd4b956941efb948badc2653119d"},{"Name":"A42_4.00_01_09_2026.fwpkg","ProductId":"a745e380a94147888b60792dcbb594a8","VersionId":"74da516248ea426786d4219f64383afc"},{"Name":"cp068344.exe","ProductId":"19810cc433a442df903276a4b0c34598","VersionId":"665a87f4c02a4ebe92c62a3c9866c192"},{"Name":"16_35_8002-MCX515A-CCA_HPE_Ax.pldm.fwpkg","ProductId":"96fe9c5a9b9741d5bcf4ae73623359e0","VersionId":"a81c9cecac1b4a8fa8d6901c0532a8ae"},{"Name":"26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.fwpkg","ProductId":"3af72b6238454de589e484681033279c","VersionId":"3ddc1bf7dbbb4a3f823e4a876f8d79ed"},{"Name":"cp069538.exe","ProductId":"7998b80f937f47828d4693eb2d620eec","VersionId":"9ea3595ca30346e2b4f4795669106964"},{"Name":"U44_3.72_01_09_2026.fwpkg","ProductId":"f2f901fd357f4c6692fae66dcbbb15ed","VersionId":"9a604862d25e41de88e4d1afea320efe"},{"Name":"cp069520.exe","ProductId":"b5747db463a34c8c8ef853b408ae6b5c","VersionId":"1c61d8d675f54d34beb3a14863e597f6"},{"Name":"16_35_8002-MCX512F-ACH_Ax_Bx.pldm.fwpkg","ProductId":"0a8a267d13ac4d5588a19d1f0bcc2f5d","VersionId":"d94a720ec9f6438fb5481e8c958847a1"},{"Name":"26_45_1020-S2A69-63001_Ax_header.pldm.fwpkg","ProductId":"a77901ff235c43f18df58616eefb654e","VersionId":"e2fbadb5ead3419e9adfd4a63f824341"},{"Name":"cp069727.exe","ProductId":"45e734b674094fd09fe52836988b3440","VersionId":"ce1f27b87467497c9a70f6bfd3ebf4b3"},{"Name":"cp069641.exe","ProductId":"fb9faa50a5034cfe8c3861f763b25770","VersionId":"3415b62c2b414ab18dcdf0162cb564f1"},{"Name":"cp068327.exe","ProductId":"635ad6621b8d4c52b8b9de3325345e84","VersionId":"65d2976282394c82900b937b5ee93fc0"},{"Name":"CP065930.zip","ProductId":"5e76fbf672b8432aa6436d748dacb463","VersionId":"e55788193b7641ea9c26ad4ae15c77bc"},{"Name":"firmware-hdd-ca21e169e2_0HPG1-1.1_amd64.deb","ProductId":"213beba0c6a2454792ef817e13082a5c","VersionId":"8fad6cd2a12c4daabf33267834c93ef4"},{"Name":"CP066266.zip","ProductId":"c101b138be5d4ee79271a6725d6813d4","VersionId":"8a9d3371bcc34b00baf2141b4ce8a1d0"},{"Name":"CP069172.zip","ProductId":"4f319faf890642fc80a3d8719760c121","VersionId":"a03f9ce066e24c478d4982121ae9620c"},{"Name":"CP066003.zip","ProductId":"ec5fd859b967489ab6f67ad677712984","VersionId":"f33261fbafa04ae9884d1df548b7524d"},{"Name":"cp070226.exe","ProductId":"00459d4dc4844a0c9aaf3dd87b1a7fe8","VersionId":"b4c3cb38bebd455b8edc86e43d598cab"},{"Name":"CP070091.zip","ProductId":"fdb3892daac8474c8262b342acf8f35f","VersionId":"d936ccd4cd9d4c80921fc3e295950cee"},{"Name":"cp068655.exe","ProductId":"17b00802f88a41f591cee6102caaf9d2","VersionId":"fb460e6ce42541ccaa5dad6a16ccd663"},{"Name":"Seagate_Summit_SUMMITSUANG1.fwpkg","ProductId":"79949863b3a5452487d1035ae487743e","VersionId":"ea555e67d9a742e8bdd8e6455315b8b1"},{"Name":"firmware-hdd-7a1edae8e7_0HPG1-1.1_amd64.deb","ProductId":"f87c073a909044b99d96fdb0f46f7c69","VersionId":"5e2b7945a07543b4aca406ee45938842"},{"Name":"cp067481.zip","ProductId":"ae807ea8d44943a3b60bbbbd54cd062d","VersionId":"eb551c6b6b314fbfa83789debb75d74d"},{"Name":"cp070249.exe","ProductId":"18633ffffaeb4435bcda138419e66c7a","VersionId":"f1b14712b7c142dbbbb8d5192e5b870b"},{"Name":"amsd_4.5.0-2107.3-ubuntu24_amd64.deb","ProductId":"d9d151c798d94a31a9d263cef309ab70","VersionId":"7a29cd8572214a6fb508a00566f2fec9"},{"Name":"firmware-nic-bcm-nxe-1.25.5-1.1.x86_64.rpm","ProductId":"7dbb2b9a498c4df1a461e7b3079cc8f5","VersionId":"39afcf44527449b4a8fb66060255b6b2"},{"Name":"CP067762.zip","ProductId":"58058fc7c39a49caa2844dbe139ab3f9","VersionId":"8f951512a1dc47adac31d8c51080aa2b"},{"Name":"cp069722.exe","ProductId":"094c75ee866a4b1bb6f0e035ac316695","VersionId":"60c84d67122f4120814e871a3b5341df"},{"Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.rpm","ProductId":"d1422347af3f4f888596c242a7fdb7a6","VersionId":"10f65b3327384eed803da4c0f160f230"},{"Name":"firmware-hdd-c7df7ceedb-HPD9-2.1.x86_64.rpm","ProductId":"e3abad55c63d42f3bfc00d8212a8e9d4","VersionId":"1d6229f8dc1e47bdbf9d5dbc3f39809b"},{"Name":"ssacli-6.60-8.0.x86_64.rpm","ProductId":"51c52bf006bd4c60b09797563ff886bf","VersionId":"5ee7637cddbb4b778e4943aa0b18c662"},{"Name":"kmod-igb-5.19.4-1.rhel10u0.x86_64.rpm","ProductId":"74e8451e230741319455926a99f9eebc","VersionId":"ff746205df92495a9ed3b31776163ba8"},{"Name":"hp-ixgbe-kmp-default-6.2.5_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"3ab4de78da484144892d6ddcd8fd9b97","VersionId":"231b867aabf04de799c7361dde7b9812"},{"Name":"hp-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"3ab4de78da484144892d6ddcd8fd9b97","VersionId":"231b867aabf04de799c7361dde7b9812"},{"Name":"firmware-hdd-42aff4675b_0HPD5-1.1_amd64.deb","ProductId":"eb308b8c4ae741aa983a2b26d428e1e8","VersionId":"e0d77138af284d2bbe04785348c14802"},{"Name":"CP066263.zip","ProductId":"6d5cd83fc05f4da0a652797154f87a4c","VersionId":"ac62c5f3848048bab2198cffa62bafad"},{"Name":"cp070341.exe","ProductId":"707f07cb4d404d119f2788d168e17586","VersionId":"247883a235ae4eba83e5dd3e0a27f663"},{"Name":"hponcfg-6.1.0-0.x86_64.rpm","ProductId":"db808d6aa2e24648bcc5e3f46d635b1a","VersionId":"6abdf231475c435c92bb558b96dfc97b"},{"Name":"CP068729.zip","ProductId":"a08198f75ae64d5f81f313aee3e10a81","VersionId":"e507085ad84f46a49d4efa5d0809c1da"},{"Name":"16_35_8002-MCX562A-ACA_Ax_Bx.pldm.fwpkg","ProductId":"a6a815c1e19641d7b77e2e862e63ca3a","VersionId":"3ff097f4cf984edc81f6a4c3ee15a91b"},{"Name":"CP065977.zip","ProductId":"a1b0fb5619dd4bf685499171488aaaa2","VersionId":"3997df854d184cccb8bf94004912f89b"},{"Name":"firmware-hdd-e0171a2936_0HPG4-1.1_amd64.deb","ProductId":"f643d6c27d8f4b5d8eb0ee9c718b2a48","VersionId":"83ec1fa034ee4b5eae1799f1161a15bd"},{"Name":"cp069739.exe","ProductId":"67fb0d734fd248cca1eff5e7b321a8b6","VersionId":"3c4ee434232a45659b386e450c35ec11"},{"Name":"firmware-system-u45-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"1f91b74faf084255b33a9e102dcf221d","VersionId":"fed2903678e54d9ca4b2da6639198be8"},{"Name":"cp069705.exe","ProductId":"95e1a7b8a2664cd8b8d67128eff9bb87","VersionId":"77d7d74fe2a4417e91c40096649dc637"},{"Name":"CP065991.zip","ProductId":"eaadba373a2b4b7ab82c00e6e1f55628","VersionId":"ba3b6d5b24a24394ab8fb7f685fa7394"},{"Name":"kmod-smartpqi-2.1.38-022.rhel10u0.x86_64.rpm","ProductId":"8c4f7b25cd054f74b804a271ef25619f","VersionId":"13f5a57fd4bb451c85bc523068e5002b"},{"Name":"firmware-nic-qlogic-nx2-2.37.0-1.1.x86_64.rpm","ProductId":"5f7dae044b3b4d97823b1cfc69305837","VersionId":"67291762a5054079aef09cf140b67273"},{"Name":"BCM235.1.164.14_BCM957414A4142HC.fwpkg","ProductId":"435031f572ea43b79bd116d63a99a58a","VersionId":"17152b23fa524ee88df95b94f1017296"},{"Name":"cp070412.exe","ProductId":"4efc4b5fce384054939496405bc41d6b","VersionId":"ac220d665e8c416882baad1fef6a7e59"},{"Name":"mft-4.33.0-169.rhel9u6.x86_64.rpm","ProductId":"266a0b8481ca4005841140656323155c","VersionId":"629df68815684bcd87655dca99d5cf7c"},{"Name":"kmod-kernel-mft-mlnx-4.33.0-1.rhel9u6.x86_64.rpm","ProductId":"266a0b8481ca4005841140656323155c","VersionId":"629df68815684bcd87655dca99d5cf7c"},{"Name":"cp070160.exe","ProductId":"8bfd6c84c6a049339ae439f038925df1","VersionId":"e0a9f3024b504c6cad7c0bc69a8e2c76"},{"Name":"cp069526.exe","ProductId":"ed78d2df04834204b8977e0aaa96c64a","VersionId":"4021bcf03a3e4c79a66a98e6c676685a"},{"Name":"CP068070.zip","ProductId":"fc28c0050f9d4a8a94e83f990b230b39","VersionId":"b8457b1f53d44a82aa36c0ab5d8b9619"},{"Name":"firmware-hdd-8fafc9efb2-HPD8-5.1.x86_64.rpm","ProductId":"9fd1abd8973f4c09aa450e541dc4ee41","VersionId":"d983b2865074432aa1669f5c011e58ff"},{"Name":"firmware-hdd-12304c1aca-HPG6-6.1.x86_64.rpm","ProductId":"205e86b4ae1e4a28ae1e3cf39faf17ba","VersionId":"aeeaaa3ea8b3407f9705db0c962f269a"},{"Name":"SPSGen10Plus_04.04.04.802.fwpkg","ProductId":"6e357a862ebf4f379b5f531a7eb46680","VersionId":"46aee4f591d24444a982cbadae0904ba"},{"Name":"CP065970.zip","ProductId":"c5274a8d3e3e40d790c226da85bd84aa","VersionId":"9ca3dd9ecb244e43acb9e5fe9d0ec0cb"},{"Name":"SKHynix_PE10X0_KPE10x0U3DK1.fwpkg","ProductId":"9b11c8b2e5814a11b64b738755f0d8ce","VersionId":"3d2e90b3dab24c458b2fd74f4d437b70"},{"Name":"U43_3.72_01_09_2026.fwpkg","ProductId":"b64e2e4187274c5798b3aa127c50ba6a","VersionId":"01734ec4abc34b148237ce4506ef5420"},{"Name":"cp069947.exe","ProductId":"6d4e51e8b4c040cc80275ae447831403","VersionId":"a341292c7bd644edbcd628ce17848c04"},{"Name":"firmware-hdd-951aefd63e-MPK7825Q-6.1.x86_64.rpm","ProductId":"7af1785af4fd43e38986cbbadda39482","VersionId":"3c7883e497ac44e0bd4a809faf8f5003"},{"Name":"firmware-smartarray-f36d4ef431-0.39-8.1.x86_64.rpm","ProductId":"e528a2af212b4bb09bfd3cb54b985653","VersionId":"ca06346fe34e428ca900a93a55162a81"},{"Name":"Toshiba_MG08Air_TAMG08SDAeD3.fwpkg","ProductId":"7cb9f47fb1de402da9399ef94a8426a5","VersionId":"6927e5439b7746e3bda2359045abc5bb"},{"Name":"CP067287.zip","ProductId":"ae4ca58542c143b088e01d17c537b7ac","VersionId":"63f3feb49383491f82800884c429d684"},{"Name":"cp068662.exe","ProductId":"182450d5bced417a85db3271254808a7","VersionId":"a6606c46ecfa49b9a3d5804df3fd45b1"},{"Name":"cp069639.exe","ProductId":"d9b51eadf7e440fc88f26963aec59690","VersionId":"947c2aba9257407c8bad37d9c29a4a05"},{"Name":"qlgc-fastlinq-kmp-default-8.76.2.0_k6.4.0_150700.51-11.sles15sp7.x86_64.rpm","ProductId":"39b3bcd8f8b243ad9879002d6ba846cc","VersionId":"245785cf99294ae1b2fef1d5cd3cdaa9"},{"Name":"qlgc-fastlinq-kmp-default-8.76.2.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"39b3bcd8f8b243ad9879002d6ba846cc","VersionId":"245785cf99294ae1b2fef1d5cd3cdaa9"},{"Name":"cp068760.exe","ProductId":"7e6f42aebfdb4390968da43b36518880","VersionId":"6747a7568d794cf59f59ca86ecccf2c1"},{"Name":"kmod-kernel-mft-mlnx-4.33.0-1.rhel10u0.x86_64.rpm","ProductId":"97767c71fca94cd4b046456f83c3475c","VersionId":"7fc799bdc4414e2a9c017dcdd10cddd1"},{"Name":"mft-4.33.0-169.rhel10u0.x86_64.rpm","ProductId":"97767c71fca94cd4b046456f83c3475c","VersionId":"7fc799bdc4414e2a9c017dcdd10cddd1"},{"Name":"cp067757.zip","ProductId":"0300daf553df4e699178bc1f12267a1f","VersionId":"1f74b0db72fd44a2aff64ce6d90b2d4a"},{"Name":"SC_ML30GEN10Plus_ME_06.00.03.708.fwpkg","ProductId":"896b673e61904db68a62db4c589536af","VersionId":"d156e66d18654adcb7d16657128597b2"},{"Name":"PICGen10-1.1.4-1.fwpkg","ProductId":"fae7c963a551489594d913b81c29f2a4","VersionId":"84e80a3fb2e04c93b20e3b09f3a5d3c5"},{"Name":"cp069155.exe","ProductId":"00184010ed0a41829836f7c60269273f","VersionId":"a5c5e6adb1ae4f7d998b40a262eea4a0"},{"Name":"firmware-nic-is-intel-1.35.0-1.1.x86_64.rpm","ProductId":"eeaaff922a754e178b46a3315fd0a64a","VersionId":"bd855fecb9b04c308ad614f4087e8ccc"},{"Name":"kmod-hp-i40e-2.28.10-1.rhel9u5.x86_64.rpm","ProductId":"2180429b88ed4e24883a75dbd70724b0","VersionId":"66b394f115194b128548cc807ba42ca3"},{"Name":"kmod-hp-i40e-2.28.10-1.rhel9u6.x86_64.rpm","ProductId":"2180429b88ed4e24883a75dbd70724b0","VersionId":"66b394f115194b128548cc807ba42ca3"},{"Name":"Samsung_PM165X_GPM1655SAMD4.fwpkg","ProductId":"39cff1d9c55641a8a5495e9c755fc456","VersionId":"d756031e46334c08a77fc0049d523b08"},{"Name":"firmware-fc-qlogic-2025.11.01-1.3.x86_64.rpm","ProductId":"bca5397d7ba147ddbb0eb4fee4d4d567","VersionId":"29029345aa4a420b9a48b15170e5cfb2"},{"Name":"cp068737.exe","ProductId":"75d8486987f7480b8e2a0459e1d59d0e","VersionId":"cd123e76da4e4e189a0aa46bfb55d4f0"},{"Name":"firmware-hdd-befd42bd64_0HPG3-1.1_amd64.deb","ProductId":"eab35afbdd7e439ba338f8fae23de885","VersionId":"4e2e15fd80234cffa9f6e16addcddb00"},{"Name":"cp069565.exe","ProductId":"1e10e20d274448bb9d2d1625880b482d","VersionId":"f97be98cdd384e279b5474536eba0080"},{"Name":"MicroserverGen10PlusSPS_05.01.05.103.fwpkg","ProductId":"134da74460bf4b5aa8511e630ba5a272","VersionId":"d5cc2651bb61477f84c5a08abe244b8a"},{"Name":"Kioxia_CM7_KACM7ALSHPK4.fwpkg","ProductId":"509f54411aaa488d8ade3254836debf4","VersionId":"5c536fa4fdef41e08d38b08ff10d54da"},{"Name":"firmware-hdd-4fbb6d96e5_0HPG3-1.1_amd64.deb","ProductId":"884d4de7b5b3447098d2f7fe88975145","VersionId":"398c6edc1426486c8084f3374a04dbcf"},{"Name":"cp070208.exe","ProductId":"cfa8fbdb2f4a4c81b7b1ee3f89f284e0","VersionId":"d181122a10ec43c3b9f0517f12b32a1e"},{"Name":"firmware-hdd-d550523365-HPD3-6.1.x86_64.rpm","ProductId":"d287970503c042a480f1860ec2c054c7","VersionId":"cd1b23f75c144dcbb22cd0a6a6da4805"},{"Name":"20_43_8002-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","ProductId":"ab42380273374a988dbcb1a25432ed96","VersionId":"168297d168de4cf58c0363f57b697c72"},{"Name":"cp070203.exe","ProductId":"f8437d6127664644832d2cd688d58903","VersionId":"3b83ac45ab8c4e908ea25b4c5baa283a"},{"Name":"cp069345.exe","ProductId":"594618f566cc4fbca055e8866278e53d","VersionId":"505b38c67605470996f78145939919a0"},{"Name":"cp070453.exe","ProductId":"f4456005e9154f53969eae342b6e27c9","VersionId":"aa09ce6818eb43509673c73cdf28ced5"},{"Name":"cp052054.zip","ProductId":"d3fcc87b38304a8db3d98d71c7c32227","VersionId":"710b214b710b478db82f6f2cc0c9f094"},{"Name":"ice-kmp-default-2.3.10_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"29a000381a7c4ec8a72063a155821a0a","VersionId":"03356d8eed65448eb25fed65b457595c"},{"Name":"ice-kmp-default-2.3.10_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"29a000381a7c4ec8a72063a155821a0a","VersionId":"03356d8eed65448eb25fed65b457595c"},{"Name":"CP065948.zip","ProductId":"660aa31b4e5e4c7fa47517faf21f93a1","VersionId":"f71d0aa764ae4c37b94b0a977af328e9"},{"Name":"CP065995.zip","ProductId":"0f2b8614c6ab40aea6c15cd633ff1402","VersionId":"8fff860ffbd24a8098156de57480237f"},{"Name":"cp066303.exe","ProductId":"d217387da75b452f91f63bc9a4605e37","VersionId":"066f16414103423396e99ff4090c6596"},{"Name":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"eb66fafd28ff4c39a42b91395104bd05","VersionId":"3829a63eceed47e4a618463a0a5f99f2"},{"Name":"CP069039.zip","ProductId":"cd60e68416444c61a56b3c63cb2d1ca3","VersionId":"cacdb2be5e8b41248e2f8d80781873a9"},{"Name":"firmware-hdd-3815d4b024_0GPK8-1.1_amd64.deb","ProductId":"28a7be894d024552967d8ce99ed30ca6","VersionId":"06f9b06ef94c48a78ab38e8e64adf569"},{"Name":"firmware-hdd-6fc985bd3b-GPK8-4.1.x86_64.rpm","ProductId":"2e5a37814cc1401a951db2b5be91b6b3","VersionId":"b5a913647d7640cd9a84628e9c1a43c4"},{"Name":"HPE_UBM4_1.24_G.fwpkg","ProductId":"1e88e3b27b814bcdbc8dcf6390d324d1","VersionId":"4e14138c4c714237bcc8bfb333533ccd"},{"Name":"firmware-hdd-95af9a555e_0HPG6-1.1_amd64.deb","ProductId":"13362528154f414b9954d2c4772da522","VersionId":"e6962e9eba8541f2b5d8f84f4091bfc0"},{"Name":"cp070222.exe","ProductId":"36877a0ed97d40a29cfe6cb469a6e72f","VersionId":"b5c0ec0c4861445791a24a401e4eb824"},{"Name":"cp069364.zip","ProductId":"614a0c688deb4def90dafbe34fab64bb","VersionId":"2ddbb9895d1240bd95290044d55545dd"},{"Name":"CP066002.zip","ProductId":"c0403221bbc14b609f9dc339f216be5e","VersionId":"f892951743024df2afb45434cce22ed5"},{"Name":"CP068477.zip","ProductId":"aedcdb1596004cf4a73ef573a3625e08","VersionId":"0e193713a6044a99a9c3686086cf1d26"},{"Name":"cp068941.zip","ProductId":"14db461db87a4c46b9be1a6560ae1f85","VersionId":"d334abf4b041473783a6d9955dbbdfc7"},{"Name":"firmware-system-u60-2.52_2026_01_09-1.1.x86_64.rpm","ProductId":"52c884546e0a44fb8cddfd654ad71e81","VersionId":"2863fa918a0a4a08b75ea40c5db5b173"},{"Name":"kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm","ProductId":"5f87cfcaa78847d59e1bfff7203034fc","VersionId":"ba6f2982065d4ddd81b475442f3249e1"},{"Name":"mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm","ProductId":"5f87cfcaa78847d59e1bfff7203034fc","VersionId":"ba6f2982065d4ddd81b475442f3249e1"},{"Name":"cp069593.exe","ProductId":"8dad994cacb24e87b613f12e36f4c8c5","VersionId":"c27bc1c39296469e83cc70adfab7c862"},{"Name":"cp064345.zip","ProductId":"1b2f6dbb532f4c6ca53c07209cbe6b16","VersionId":"efd45025f131446c8a82a2b5fbf98968"},{"Name":"cp069008.exe","ProductId":"b0150fa8c3c74fa8a3415a136a3cc117","VersionId":"93a11597a6eb4cc582ec0b9f3bb6e566"},{"Name":"firmware-hdd-6b7ce3da0e-HPG2-14.1.x86_64.rpm","ProductId":"05a81ac262384916b1fa6e922a6cada6","VersionId":"550deb8b0471468da76947e52e40beca"},{"Name":"cp068638.exe","ProductId":"38d3787c49804ab1b404f61b3cd58354","VersionId":"b0168ec5461d4a2c884ee180bec67bfa"},{"Name":"cp069946.exe","ProductId":"ae86717eaef841a7919ea42f85ca3fe7","VersionId":"3b0289c763344f37a5968a9b1d057b40"},{"Name":"CP067621.zip","ProductId":"86420e4b9b414e61bd5c2f06d883ac98","VersionId":"193f7117b10a47e49ed790009419bd5a"},{"Name":"HPE_E810_XXV4_OCP_4p90_NCSIwPLDMoMCTP_80020EF3.fwpkg","ProductId":"6adb26c5fc564f219877ab6a448e709b","VersionId":"f8c90151580642298741257c8630f8bd"},{"Name":"firmware-hdd-d39e7a7e75_0HPG1-1.1_amd64.deb","ProductId":"f64fce49b8774319b4cc4ce2ecc3d153","VersionId":"f0b4b9b2a02445ff8c61915de1c7c17e"},{"Name":"cp069949.zip","ProductId":"d473378e1f2847f48383c6be4c105511","VersionId":"b59552af1ed24caf932c71cc0bb22908"},{"Name":"A41_3.70_01_09_2026.fwpkg","ProductId":"14652a1a392747089da4a4254064ac9d","VersionId":"07df407c09e24197baa1773dc88641a5"},{"Name":"cp069566.exe","ProductId":"ff242e39c275472185612592300114ce","VersionId":"9a4d9987d9a0415894252fe50a4aec38"},{"Name":"cp069740.exe","ProductId":"81500ed23ae94776ba24fd962d1f8bd1","VersionId":"a7f6946f7005432493ab559114fd7ba5"},{"Name":"CP066001.zip","ProductId":"c19eee3c7a1046a4aeaff35e462fce56","VersionId":"082b90a7fe714b2dba1a8cee129c9946"},{"Name":"cp069529.exe","ProductId":"8bf9eb4134cf48c2a7da72633124722f","VersionId":"6d4716f3a3af4bed82474934d138ca08"},{"Name":"firmware-hdd-020fc874ad_0HPD3-1.1_amd64.deb","ProductId":"3ba9b83f17144198845124cbe477505f","VersionId":"5669ee719471471891e8aca62d3fb9ca"},{"Name":"firmware-d3000-5.04-17.1.x86_64.rpm","ProductId":"d6810024a18142b0a4b8ec4db68a4e55","VersionId":"ce8bc463b8c3413c9f7ff97743f96b92"},{"Name":"cp066321.exe","ProductId":"228e6aefb0ce46a0a7e230319e326d29","VersionId":"44cda149e93b48f6aaf0b99ce77c5d47"},{"Name":"cp067756.zip","ProductId":"4899e6b54e3941a4b9c3090a539cf6db","VersionId":"1b1532f380e843678a34a72933eeb5ba"},{"Name":"firmware-hdd-a886842a99_0HPD2-1.1_amd64.deb","ProductId":"1a121f2eb5274f1cbf1d67964da2e171","VersionId":"45d9cb0364474ec8a10d37f378652d48"},{"Name":"firmware-hdd-2c27a7a9a4_0HPD2-1.1_amd64.deb","ProductId":"e6b0d97326414c5688fb57aa0f288b70","VersionId":"69f16a9ad1444b70a92183053970b2e2"},{"Name":"kmod-tg3-3.139w-1.rhel10u0.x86_64.rpm","ProductId":"2e4ac8b988164dc087668639a95037d3","VersionId":"946679b18e0a483397d4dc7e3773f91e"},{"Name":"CP065989.zip","ProductId":"a9e8e46bd6de460ea736a9be4499f26a","VersionId":"81d8c5b2beeb482ba3508dee74c64ae1"},{"Name":"firmware-hdd-87b796d9ae_0HPD4-1.1_amd64.deb","ProductId":"5132cc00457040eca415ddc65a22d65e","VersionId":"a310702b8e7e4d10be458d762d61b637"},{"Name":"HPE_MR416i-a_Gen10P_52.32.3-6333_A.fwpkg","ProductId":"c9a4232d8cb349049f544bcc6d02e97f","VersionId":"fba646eb0ed94ee784241054f6c577c4"},{"Name":"firmware-hdd-aef2a690c9_0HPG5-1.1_amd64.deb","ProductId":"5371b499023847d7b4f19c6fa659705b","VersionId":"c75a7285155344b9a4b0cf4c8a44eab7"},{"Name":"cp069173.exe","ProductId":"5ace706167bb418f8ac30077c43e3171","VersionId":"7dd86b04242c48c98f185bf6b8bd76c1"},{"Name":"cp069543.exe","ProductId":"5413adceb7d241de900274e399d9c777","VersionId":"4a14deaf10d5470da0e2b4e08f9da3ee"},{"Name":"cp069546.exe","ProductId":"683278c3722a411eb75e30e9eb4f543d","VersionId":"34b4c250a802481791aacbcc4385ad32"},{"Name":"cp068633.exe","ProductId":"459b31cbafbe408eaf0a96421248c984","VersionId":"e41a30bd00ab4b4ba56cdbac8a2e4498"},{"Name":"cp070256.exe","ProductId":"1f3d9896fbab4dc5aed295b2183323a0","VersionId":"76cdb0876f7b421f8027b3e5a268025e"},{"Name":"cp069533.exe","ProductId":"5e67b3914b754070a44558f816a7dbab","VersionId":"a1cfc287221841b3b9741b9423a52863"},{"Name":"mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150600.21-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm","ProductId":"58dd146b67a34b2492cfd64a1feceec4","VersionId":"c075bef6e321486a9387a59ef84f58f4"},{"Name":"mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm","ProductId":"58dd146b67a34b2492cfd64a1feceec4","VersionId":"c075bef6e321486a9387a59ef84f58f4"},{"Name":"CP066023.zip","ProductId":"a4fb8dc02faf478a85519ccf77530c6a","VersionId":"3517de8f98024d459a4a29c680e11ef7"},{"Name":"CP065964.zip","ProductId":"a88170da558d4ca79c0a5aa7982152c5","VersionId":"ea988c1bdb0e488ea2464583c089174e"},{"Name":"firmware-powerpic-gen10-1.1.4-8.1.x86_64.rpm","ProductId":"d6cef3e7c9484a989ca5a04fc11b29f2","VersionId":"305cf0a5e6cf4fedb2bbda773704fad9"},{"Name":"SC_DL20GEN10Plus_ME_06.00.03.708.fwpkg","ProductId":"9a8025d60954436ba6fa5cef6da3dd18","VersionId":"2052e9792f184ea8bc1a949a0ba32149"},{"Name":"HPE_SR416_SR932_Gen10P_Gen11_03.01.44.040_A.fwpkg","ProductId":"29921b6ba8e14e7cbeb3829f2308a0f5","VersionId":"4b651fe2c7f1478eb6aa102fbf31bf1b"},{"Name":"cp070351.exe","ProductId":"c94eb717d55e4213952a8c5723962404","VersionId":"d9f050fc463a4c84943b175eb526c77e"},{"Name":"firmware-spsgen10plus-04.04.04.802-1.1.x86_64.rpm","ProductId":"78667359eec84fc9af9066672db940e0","VersionId":"99bc27d52d4742a7ae087361736f94e1"},{"Name":"Solidigm_P5x20_4IAAHPK5.fwpkg","ProductId":"953566d3c1ab4efe9b762b361100a259","VersionId":"4412e3e7c98649b3bd32cc53ac661f12"},{"Name":"H10_2.54_01_09_2026.fwpkg","ProductId":"731d832691df4216b8c0e073e857b8b7","VersionId":"0f5daaa66be24706974a1e36ac27c398"},{"Name":"CP065993.zip","ProductId":"97b8f64d84c04c1a9c4048cae29b4037","VersionId":"2c7206dd3d23401086d8b25ae4891eaa"},{"Name":"cp070450.exe","ProductId":"c09de62648424d62a24c56f856946da6","VersionId":"8bb509c565c0443b889276758c8765ad"},{"Name":"CP064921.zip","ProductId":"a271f679286141d98830336f93a8205f","VersionId":"5e1fddb843d64cc082b8f2361cbbfb50"},{"Name":"firmware-hdd-a07a420ed1_0HPD5-1.1_amd64.deb","ProductId":"4c8bf8c7de4d42f19de7d71c6056b4ba","VersionId":"9ff89ccd7ecd42f58c367388f32df0f3"},{"Name":"cp066316.zip","ProductId":"98a183458fbc454a86f635797ce90db5","VersionId":"b36a633ff667434295a5dcb82e072da5"},{"Name":"firmware-hdd-a07a420ed1-HPD5-6.1.x86_64.rpm","ProductId":"f12cb892007944f694736d03ec00543c","VersionId":"1da10066bcaf487dad617cdc66b75e8a"},{"Name":"firmware-hdd-b04257b77b_0HPDA-1.1_amd64.deb","ProductId":"a76e2531d46347fe8a21781398a9fa4d","VersionId":"2377dfa753824aa1b2fec717915b7265"},{"Name":"cp070007.exe","ProductId":"bce1dc60182942cc938b19de857de7fd","VersionId":"9c2e096616fa40d5a40729ac02f9f213"},{"Name":"CP068478.zip","ProductId":"e1df01bf9927457096858061671e6c6b","VersionId":"7b10adedc44b4ad684f4306ab603ab6e"},{"Name":"firmware-nic-qlogic-flq-1.25.0-2.1.x86_64.rpm","ProductId":"a2c850b33a31462c8693efedafbdd8b9","VersionId":"04f079dbe182468f8c1d66faa87a37db"},{"Name":"firmware-hdd-8b26d1ef02-HPD2-11.1.x86_64.rpm","ProductId":"596340d3247946aaa109faeb065a7eab","VersionId":"1b5d3a6032d24d3183a0c45f7a3a0c94"},{"Name":"IEGen10_0.2.3.0.fwpkg","ProductId":"91adee7c0766499184ce8d25a925669e","VersionId":"40c0e7a8438342b484e5d401d21392eb"},{"Name":"firmware-ml30gen10plus_me-06.00.03.708-2.1.x86_64.rpm","ProductId":"3eab1bf1c35b40e5b35b9f8cbcf441cd","VersionId":"e0fba97ca42145fda634f826ffe76d57"},{"Name":"cp069521.exe","ProductId":"794cbcecc16344ce8539a9b80f70c157","VersionId":"f339b773d97449db8bc0d1ac2bda4459"},{"Name":"kmod-qlgc-fastlinq-8.76.2.0-12.rhel10u0.x86_64.rpm","ProductId":"fcd35b42a2c44c87b93ab943ca8d2f70","VersionId":"db3f275d299745b19452ac0b19b733f4"},{"Name":"CP066011.zip","ProductId":"3fa689b1e0c54064af40f5128fac0e5b","VersionId":"6fcc9abfdf734302bb9d64b076e28505"},{"Name":"cp068902.zip","ProductId":"e01aaedc1c6c4e4090054a22e89562d4","VersionId":"c0411cf9fc97412eb6542bb54c8f589d"},{"Name":"Seagate_CimarronBP_SCIMARBPETG4.fwpkg","ProductId":"e0d3905a13b74f06a63b96091e3a0b13","VersionId":"0be86abeb599456ea5c1845fc69ef581"},{"Name":"cp069363.zip","ProductId":"ec9be2d62b6d4bb78b41f4e500d70240","VersionId":"2087ae0c509a4375b1e87fbc7bc1c3d4"},{"Name":"BCM235.1.164.14_BCM957416A4162HC.fwpkg","ProductId":"4b7bb75be74941e8987c342978cb18f9","VersionId":"2b556b376e864c61a79dc8d808bc1e3e"},{"Name":"CP068978.zip","ProductId":"7ead0459ae26493fa240dac6ad17d606","VersionId":"bf6ea1549af04f4cbc89af0a38a94a6d"},{"Name":"cp066305.exe","ProductId":"1012a84c719148b1b9e7357e885d2199","VersionId":"033a9645c66c47ef8b86aec84e0f5f23"},{"Name":"cp067917.exe","ProductId":"ccde97956825448f97ee8427bc2eccdb","VersionId":"9ebffb2cdb5344b9b7b9694171275a05"},{"Name":"firmware-hdd-8d68452816_0HPD9-1.1_amd64.deb","ProductId":"5f09aeda85cb45139823fad0b151d05f","VersionId":"4cbc796f99074286878645e8ed5a92bc"},{"Name":"cp068623.exe","ProductId":"840d26617d5744de973393a116bf720d","VersionId":"c3565c0707884cfd8788bdb7d13f3b49"},{"Name":"libbnxt_re-235.1.164.14-sles15sp6.x86_64.rpm","ProductId":"b00b4afad66b4dd386d098e91550601d","VersionId":"980bc003e1324c0089fc7f56d030bb97"},{"Name":"cp069556.exe","ProductId":"b88ebb63a68747808884160b11c000eb","VersionId":"0e275b595b61436795ae02fc509d51c6"},{"Name":"CP069156.zip","ProductId":"84e7c2b1f88e4ba3ad8fe3ec63fe5a60","VersionId":"dab819845e2c416f9615b377a41a073e"},{"Name":"cp068755.exe","ProductId":"e94dfd89626f4fc992d59a1c00e08f54","VersionId":"88b39410f2fd41e3a7c608a38833448d"},{"Name":"firmware-system-u43-3.72_2026_01_09-1.1.x86_64.rpm","ProductId":"d3e8a053234f49d9a3735931f34c77c7","VersionId":"7a009f7d37bd48e2b15d13ee77a2c902"},{"Name":"cp066324.exe","ProductId":"954c63f35d4743b2b629b5d17bfd860b","VersionId":"5652edae891844e78f5039b595ec4a61"},{"Name":"HPE_MR416i-p_Gen10P_52.32.3-6333_A.fwpkg","ProductId":"3f857d7b01734aa494f8146516002d2e","VersionId":"98769e560a3445ecbeffcbf2cbf612a7"},{"Name":"cp068666.exe","ProductId":"8e8fd25144334177930f2db95d492320","VersionId":"4949af45d6614c159f064c1c94c08476"},{"Name":"CP065958.zip","ProductId":"d7a820130b1346d2a8d4377d479232cf","VersionId":"de5f63eab149463783b82001b23764bb"},{"Name":"firmware-hdd-faf39e0ff7_0HPD9-1.1_amd64.deb","ProductId":"ad11e7e4956147cc81b160d5c8d519df","VersionId":"b84cdb6503604ad4ab61625e6b258c61"},{"Name":"cp068731.exe","ProductId":"8e4da865e5b44ea38e4b650ce9a93715","VersionId":"8aa7071f46d84a058e94d592872206e0"},{"Name":"ssaducli-6.60-8.0.x86_64.rpm","ProductId":"7a0e2103ab3d449ea173c873ce94c871","VersionId":"b655bf12f1ec45248db5262428b859da"},{"Name":"cp068758.exe","ProductId":"3b6a8a58b8154bb1b3a7b5b4416448b8","VersionId":"82fb0e5310174d9195ce89abea9bf90c"},{"Name":"firmware-hdd-951aefd63e_0MPK7825Q-1.1_amd64.deb","ProductId":"5f659aa091e040538f3e83b28f048f1f","VersionId":"c4ea7038d4c347e69fb94a7078bba200"},{"Name":"firmware-hdd-6b7ce3da0e_0HPG2-1.1_amd64.deb","ProductId":"5ccf2d3c6d81402baa3db964a93e8c96","VersionId":"9482473f716747c0b19615fdd20186d0"},{"Name":"firmware-hdd-ef93133161-HPD4-4.1.x86_64.rpm","ProductId":"07a5f3ddb9bd4168818fb38406e49473","VersionId":"728eef229104453693c5a71e677c1770"},{"Name":"firmware-system-u41-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"d36b5614c00b4d00b66a58209cc5bffb","VersionId":"dd67d87fae5b4df1b390bdae09f940b8"},{"Name":"Seagate_Summit_SUMMITSUASG1.fwpkg","ProductId":"575b91de95af482eb3a08ed94402e2c3","VersionId":"675c69d416134f789231a11d446f13a9"},{"Name":"cp069945.exe","ProductId":"3126d8d47de5417a878b30ed83f0673f","VersionId":"60a0f741fa9940ef963118e35e24db79"},{"Name":"kmod-qlgc-qla2xxx-10.02.15.00_k1-1.rhel10u1.x86_64.rpm","ProductId":"376766abc4f1493fa567046abeb8b7d6","VersionId":"a8164eb9fed14378adc4f977ed8363b9"},{"Name":"cp069552.exe","ProductId":"5f4b3c5f1985447a820cdfec1e7b0bb1","VersionId":"3116ddb609f54ed5ab42139bfadf6447"},{"Name":"cp069362.exe","ProductId":"7f5cc2735e814d67a516e6e72cb03eec","VersionId":"6c1e95ec13354cdd998cd911da77c3d9"},{"Name":"cp068665.exe","ProductId":"260b73b77b824e60a7231a400ce24c25","VersionId":"dd4d0089d26745a78f0c891836635576"},{"Name":"firmware-hdd-017797f12e-HPD4-6.1.x86_64.rpm","ProductId":"ba1b35ce71154e9e8335778f038c2885","VersionId":"118afb87880649a9ac415ea8d33bf1df"},{"Name":"kmod-hp-igb-5.19.4-1.rhel9u5.x86_64.rpm","ProductId":"eaf211f134ef40ba8eea9bd4163e6e57","VersionId":"9b0df02d8403461ea2b98e2ea4df0d64"},{"Name":"kmod-hp-igb-5.19.4-1.rhel9u6.x86_64.rpm","ProductId":"eaf211f134ef40ba8eea9bd4163e6e57","VersionId":"9b0df02d8403461ea2b98e2ea4df0d64"},{"Name":"cp068752.exe","ProductId":"f0e80dda550e422981f666fd854cb6f6","VersionId":"658a48b6cc0742208d5882f3f0d95021"},{"Name":"ssaducli-6.60-8.0_amd64.deb","ProductId":"2f9cefc3934e4e93835fb42cb71a4161","VersionId":"51e6c4ff673845d89df996472460dfb1"},{"Name":"cp068749.exe","ProductId":"d1880357890d41959529b109e2a869e4","VersionId":"c31b9cb8342244b7aab937df42e467f7"},{"Name":"cp069532.exe","ProductId":"24ef5d7f7f9443c598148daa0f16246b","VersionId":"dedc3c1f25d548b096eafb4386f0f946"},{"Name":"cp069585.exe","ProductId":"7dd14e7585784238bb6caec32dcf1d80","VersionId":"49fe9081c9ee40c6ad89c24ecc0b358b"},{"Name":"cp068645.exe","ProductId":"b0d91a06dd9c4473a208b93b1c088e41","VersionId":"11806acbfb014d739d8e94a6b58e1ef5"},{"Name":"CP065999.zip","ProductId":"809cff8704ac44759685c033bb7b76d3","VersionId":"fb0ba8f67f8f42d3ba9f214d072fe390"},{"Name":"cp069587.exe","ProductId":"effc199f67764de3b570f964be1aa0ce","VersionId":"08a87fb5ad0840a6b85d1093a80d9fd5"},{"Name":"cp069694.exe","ProductId":"957b79699cf847b3bc804b96d1108938","VersionId":"1cc8cbad04d4490aa3fb86d133642ffa"},{"Name":"cp068637.exe","ProductId":"8ebc8805a4344ec4a24a5c7109c6e07f","VersionId":"3b227ec4622c46b1a335f928e066d97d"},{"Name":"firmware-system-u30-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"1368ab3d45fb40b799c33ccbe297c322","VersionId":"3181c781c17f4f05bbf49bc628bfed5f"},{"Name":"cp068543.zip","ProductId":"270849c2dba647ceb1f5f641d466f681","VersionId":"108c2c6c505e48f1a6dd0e16f4cb61d5"},{"Name":"HPE_UBM1_1.46_B.fwpkg","ProductId":"a4ccd8709d044858ab5bf64233046176","VersionId":"a663f1f50ce245ec806abddbf83cd919"},{"Name":"firmware-system-a43-4.00_2026_01_09-1.1.x86_64.rpm","ProductId":"be8e1065c14f4a6883e7804dae8c691e","VersionId":"ca788d17e6324d83b383b30df8423220"},{"Name":"Seagate_LangeBP_SLNGBPHPESD5.fwpkg","ProductId":"5521a7a96ce64d8a92b5aab1a6147b6e","VersionId":"698b806535e54899a0d8cfa4fae3990c"},{"Name":"firmware-hdd-18e328f036_0HPG8-1.1_amd64.deb","ProductId":"a730c4df025740309831b257ee5cb3dd","VersionId":"1011ccaa4aec47aa82b4a479e417e4e5"},{"Name":"firmware-system-a40-3.70_2026_01_09-1.1.x86_64.rpm","ProductId":"d313ecbde1f54151bf42ad357e6b94ad","VersionId":"187f29f6e3d34ff2b6d40607c41795ed"},{"Name":"U46_2.54_01_09_2026.fwpkg","ProductId":"d8cf5e47a4564ba6bcb2ea1177a33ff1","VersionId":"bdfb4e08a98a404e9f2f94a90fd34f11"},{"Name":"SKHynix_PS10x0_KPS10x0U3DK2.fwpkg","ProductId":"7fc78ba6f4174eae8b7e06638191844b","VersionId":"cf0615bbfbbd47ed854ab307d9a173f5"},{"Name":"firmware-hdd-020fc874ad-HPD3-3.1.x86_64.rpm","ProductId":"dd0182917bf14543bf436162a2a05331","VersionId":"46f9341a20c14989b9f4611fd9c3e917"},{"Name":"Kioxia_RM6_KARM6ALSHPD1.fwpkg","ProductId":"acccc3a79b934a56bc23c6e1a1b8169b","VersionId":"9f078413ab6e4fb6aeab7cecca2f01a6"},{"Name":"firmware-hdd-8173816d98_0HPD6-1.1_amd64.deb","ProductId":"8adcf62d3b4a41379b595de71bd60c8d","VersionId":"1efea56866214eb8ab1656c678923749"},{"Name":"CP069048.zip","ProductId":"8bcfdc333663490ba14bb0a7e2286062","VersionId":"abc96569b95b454ba4dd8f87cbe93681"},{"Name":"cp069349.zip","ProductId":"85a59acb7d634eb691745a6c9906ad03","VersionId":"6b15829f58204225911f6452976f1aa8"},{"Name":"firmware-hdd-3496cc4743_0HPG3-1.1_amd64.deb","ProductId":"263869a9bde4406ca10c065a64fecfad","VersionId":"594982095a0546c481633bb1c1120d4d"},{"Name":"firmware-system-u40-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"672edcd2af9a4bd18876e5e3192cd831","VersionId":"e09234a0cb084d84ae324b9ac53e40a4"},{"Name":"kmod-elx-lpfc-14.4.731.6-1.rhel10u1.x86_64.rpm","ProductId":"74b3fe77108f45dc915915f121f04357","VersionId":"7647aad973dc463d88c46a6ab6c0366d"},{"Name":"firmware-hdd-12304c1aca_0HPG6-1.1_amd64.deb","ProductId":"11da5efc39044b5bb1d1491457b48fdd","VersionId":"eb7ff89f1b6a4466b34d0dee0b507986"},{"Name":"firmware-hdd-b04257b77b-HPDA-7.1.x86_64.rpm","ProductId":"4cf79b782386458fa01aea2ca94f4962","VersionId":"740138d8fd3b4dc695032808f4b040d1"},{"Name":"HPE_UBM6_1.06_A.fwpkg","ProductId":"923bb6bba3254a6d80257c1bf056f39d","VersionId":"7b7e1b259798400e9d831a9ae7dc63e5"},{"Name":"cp069549.exe","ProductId":"7a38c76de8ff4383970907d2998b1740","VersionId":"0c703a78e2174310a9807b7cb69ced22"},{"Name":"CP066510.zip","ProductId":"d0558c4ca40d4c1889688fd366d72022","VersionId":"4d4eeb5fca8642ac80b8d8ba61ff0ffb"},{"Name":"Kioxia_PM7_KAPM7ALSHPD4.fwpkg","ProductId":"d5dd0878f5bc46a1b2bda19d450bbffe","VersionId":"773c466c982042fea8769d7ddbc070dd"},{"Name":"firmware-hdd-3496cc4743-HPG3-3.1.x86_64.rpm","ProductId":"f6fccbc5aefd411688310b509bfaeaec","VersionId":"65c8ee31d6f74304bdfd954b3fb127a3"},{"Name":"cp069135.exe","ProductId":"25bee0f636714c0e8bface2301234fec","VersionId":"50614c2a24d44149a348e14e1aea3cc2"},{"Name":"CP069157.zip","ProductId":"ac4d46dcda694f51abe34e6378a53487","VersionId":"d0e2107598234bfaa671aaf70e77861d"},{"Name":"CP065934.zip","ProductId":"cfe4c5a213fb4be397a8b588efd29cc1","VersionId":"8ac58cbcb5c54055b4aeda91c2755e86"},{"Name":"cp069695.exe","ProductId":"d6464fc039cd4a77b22febd8762dca03","VersionId":"3fd3503e391649f990dc2557579bb78f"},{"Name":"firmware-hdd-35fd24601f-HPD5-6.1.x86_64.rpm","ProductId":"c4ef0470aa934a20948f1a88d8eff26d","VersionId":"431afbfd2b4549a49c85282054fc0115"},{"Name":"cp069636.exe","ProductId":"10b8cebc40fb4b69b234ff81bd7e1d1f","VersionId":"5c9a9559677842a8bac1e869efe1f08d"},{"Name":"storcli_007.3212.0000.0000_all.deb","ProductId":"1ba6abb4e9ff40ab8c8d2a6c0f1a1860","VersionId":"ea314d781ac146b79f767639545d4066"},{"Name":"mft-4.33.0-169.sles15sp7.x86_64.rpm","ProductId":"3178a35014a54eb187ac32bf0e1852e0","VersionId":"c96c133d9d3d48b3abe4b05698877151"},{"Name":"kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"3178a35014a54eb187ac32bf0e1852e0","VersionId":"c96c133d9d3d48b3abe4b05698877151"},{"Name":"cp068748.exe","ProductId":"83ce77cbc6db45d29c95de38716f222e","VersionId":"e33b47e3812f43beab0d6c1014b6cbcf"},{"Name":"firmware-hdd-e0171a2936-HPG4-5.1.x86_64.rpm","ProductId":"a905a1ce40514e0aba7f765d4f2557ae","VersionId":"e4f96604ef9a4309ade87be7cfdcccea"},{"Name":"firmware-system-u34-3.62_2026_01_09-1.1.x86_64.rpm","ProductId":"0fb6a42a8b224caba8a145e0ac696d52","VersionId":"9970de07e95b44ed9c3fefbecab84af0"},{"Name":"cp069563.exe","ProductId":"8484f11834644aea8a2a14d1d0d58403","VersionId":"1e029bdb27234af1b25a757bd92ea0a5"},{"Name":"cp068766.exe","ProductId":"ae6b2b73e1ee45bc9e25c451f9dd6d2f","VersionId":"0fce20322b36427496f326ea294a9d42"},{"Name":"Seagate_Summit_SUMMITSUSSD3.fwpkg","ProductId":"ae57ff279aab4e628b9d7923b0985d81","VersionId":"54c9602889d54d00bfe7cae757318823"},{"Name":"U48_3.72_01_09_2026.fwpkg","ProductId":"b8b6b31789ce4119a48876ba4b89c81f","VersionId":"41a82d4d432c4b47a326bc31742d93ca"},{"Name":"HPE_MR216i-p_Gen10P_52.32.3-6333_A.fwpkg","ProductId":"87a7eb56c25b4c4c98ceb5ea24664524","VersionId":"fa3158ccef374a59b773a2e5bc75aec7"},{"Name":"firmware-hdd-ec908c3650-HPG9-7.1.x86_64.rpm","ProductId":"38437d438933420e8063d6e963ffd91f","VersionId":"fa7d4ab4a2a243a6b4e8ce62b0daaf7b"},{"Name":"firmware-hdd-95af9a555e-HPG6-7.1.x86_64.rpm","ProductId":"e8a7c3696813408f916249b859b6b722","VersionId":"3037e9a83dcc4cb8b2f5d02c49c2165a"},{"Name":"firmware-hdd-82894b9e0a_0HPG1-1.1_amd64.deb","ProductId":"e387ceb63f224ab6a638f85cac2fa1d9","VersionId":"72a0a27f09db4a51add243a77fa1d75a"},{"Name":"firmware-hdd-9475583fb5-HPG1-6.1.x86_64.rpm","ProductId":"cf3d0ea161014094b2ae4ebd26456a93","VersionId":"09fad2ae6ae840ae99f4ef37015c7219"},{"Name":"CP066269.zip","ProductId":"92d52e2161c24f8f9ff633da842f814c","VersionId":"9ee8bc81871a46219e0901843d2c0086"},{"Name":"SC_MicroServerv2GEN10Plus_ME_06.00.03.708.fwpkg","ProductId":"189fb9052e994ac694bd5d6fb410f76a","VersionId":"352e23b716be4102b972bb4003d4db6c"},{"Name":"CP065945.zip","ProductId":"738515ca087c45c4b01b62883007bfb8","VersionId":"0e038dbf393b4835a98f9e12bce3c8cc"},{"Name":"cp069536.exe","ProductId":"6510bb61b44e4df589649e5642d32bf1","VersionId":"f1361761f78a4dc4a82fbef98f7f6865"},{"Name":"firmware-hdd-cf0b6cabe1-HPD4-7.1.x86_64.rpm","ProductId":"fa3afb08b69b4eb3ac32d9088c68d3a9","VersionId":"c412afec4b864fbe9252ae577a0a28fa"},{"Name":"cp069553.exe","ProductId":"be56d38accd045cca89d446f2db8440b","VersionId":"445f491396d8448eba420dcedec44ce2"},{"Name":"hp-iavf-kmp-default-4.13.16_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"5156ee2ce74d4685bd9c2931c6170220","VersionId":"b86bfe25c6d74118b9182e299f8d2d0b"},{"Name":"hp-iavf-kmp-default-4.13.16_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"5156ee2ce74d4685bd9c2931c6170220","VersionId":"b86bfe25c6d74118b9182e299f8d2d0b"},{"Name":"kmod-bnxt_en-1.10.3-235.1.164.14.rhel9u6.x86_64.rpm","ProductId":"c549eb5726da4e0ab54cbcdd6abecebd","VersionId":"66e0ee09018e463c9b0da88f6f3702f5"},{"Name":"elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"83fed5e4a427414fb0792283dd57ec37","VersionId":"3be72de3c7ed4d1b94905d0eb772f557"},{"Name":"cp064706.zip","ProductId":"c9a566daebdb4bd4a0f22d28877b9f3b","VersionId":"5b72663a36ec4ac2a8e3084a2ac63e87"},{"Name":"cp068658.exe","ProductId":"ed9a4b98eb61471ab66480b22d4e9c4f","VersionId":"0055eb2e6f1a4b82856baa2214762650"},{"Name":"Solidigm_S4X20_4IYYHPG4.fwpkg","ProductId":"6f38004b166d42068a292e455179565f","VersionId":"8ae279136d1146d9a07e0ced51a7a9cd"}],"Description":[{"Lang":"en","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus (SPP) is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. This solution uses Smart Update Manager (SUM) as the deployment tool and is tested on all HPE ProLiant Gen10/10 Plus servers as defined in the Service Pack for ProLiant Server Support Guide located on the SPP TechLibrary page."},{"Lang":"ja","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus (SPP) is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. This solution uses Smart Update Manager (SUM) as the deployment tool and is tested on all HPE ProLiant Gen10/10 Plus servers as defined in the Service Pack for ProLiant Server Support Guide located on the SPP TechLibrary page."},{"Lang":"cn","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus (SPP) is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. This solution uses Smart Update Manager (SUM) as the deployment tool and is tested on all HPE ProLiant Gen10/10 Plus servers as defined in the Service Pack for ProLiant Server Support Guide located on the SPP TechLibrary page."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"DocumentationNotes":[{"Lang":"en","Value":"<p>Gen10 and 10 Plus SPP 2026.01.00.00 release supersedes Gen10 and 10 Plus&nbsp;SPP&nbsp;2025.11.00.00.</p>"},{"Lang":"ja","Value":"<p>Gen10 and 10 Plus SPP 2026.01.00.00 release supersedes Gen10 and 10 Plus&nbsp;SPP&nbsp;2025.11.00.00.</p>"},{"Lang":"cn","Value":"<p>Gen10 and 10 Plus SPP 2026.01.00.00 release supersedes Gen10 and 10 Plus&nbsp;SPP&nbsp;2025.11.00.00.</p>"}],"Id":{"Product":"5d74fe753828448f9472abbeb67af11d","Version":"bee328fea0ba4a26acb66386bf6e258e"},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0in; margin-right:0in\">There are two methods for using the&nbsp;Service pack for HPE ProLiant Gen10 and 10 Plus to update your ProLiant servers: Online mode and Offline mode.</p><p style=\"margin-left:0in; margin-right:0in\">Online mode - Runs on a Windows or Linux hosted operating system</p><ul><li>Interactive mode - Follow the onscreen steps to update firmware components<br />To initiate deployment in interactive mode, run the launch_sum.bat (windows) or launch_sum.sh (Linux) script which is found in the root of the .ISO image</li></ul><p style=\"margin-left:0in; margin-right:0in\">Offline mode - Server is booted to the .ISO image</p><ul><li>Automatic mode - Firmware components will be updated without interaction<br />Automatic mode will by default run firmware update without any user interaction after sitting 10 seconds at the menu screen&nbsp;when&nbsp;an&nbsp;SPP .iso image is used to boot the server.</li><li>Interactive mode - Follow the onscreen steps to update firmware components</li></ul><p style=\"margin-left:0in; margin-right:0in\"><strong>Click here for the</strong> <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=dp00007290en_us\">Gen10 and 10 Plus SPP Release Notes</a></p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0in; margin-right:0in\">There are two methods for using the&nbsp;Service pack for HPE ProLiant Gen10 and 10 Plus to update your ProLiant servers: Online mode and Offline mode.</p><p style=\"margin-left:0in; margin-right:0in\">Online mode - Runs on a Windows or Linux hosted operating system</p><ul><li>Interactive mode - Follow the onscreen steps to update firmware components<br />To initiate deployment in interactive mode, run the launch_sum.bat (windows) or launch_sum.sh (Linux) script which is found in the root of the .ISO image</li></ul><p style=\"margin-left:0in; margin-right:0in\">Offline mode - Server is booted to the .ISO image</p><ul><li>Automatic mode - Firmware components will be updated without interaction<br />Automatic mode will by default run firmware update without any user interaction after sitting 10 seconds at the menu screen&nbsp;when&nbsp;an&nbsp;SPP .iso image is used to boot the server.</li><li>Interactive mode - Follow the onscreen steps to update firmware components</li></ul><p style=\"margin-left:0in; margin-right:0in\"><strong>Click here for the</strong> <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=dp00007290en_us\">Gen10 and 10 Plus SPP Release Notes</a></p>"},{"Lang":"cn","Value":"<p style=\"margin-left:0in; margin-right:0in\">There are two methods for using the&nbsp;Service pack for HPE ProLiant Gen10 and 10 Plus to update your ProLiant servers: Online mode and Offline mode.</p><p style=\"margin-left:0in; margin-right:0in\">Online mode - Runs on a Windows or Linux hosted operating system</p><ul><li>Interactive mode - Follow the onscreen steps to update firmware components<br />To initiate deployment in interactive mode, run the launch_sum.bat (windows) or launch_sum.sh (Linux) script which is found in the root of the .ISO image</li></ul><p style=\"margin-left:0in; margin-right:0in\">Offline mode - Server is booted to the .ISO image</p><ul><li>Automatic mode - Firmware components will be updated without interaction<br />Automatic mode will by default run firmware update without any user interaction after sitting 10 seconds at the menu screen&nbsp;when&nbsp;an&nbsp;SPP .iso image is used to boot the server.</li><li>Interactive mode - Follow the onscreen steps to update firmware components</li></ul><p style=\"margin-left:0in; margin-right:0in\"><strong>Click here for the</strong> <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=dp00007290en_us\">Gen10 and 10 Plus SPP Release Notes</a></p>"}],"LangList":[{"Lang":"en","Value":"English (US),Japanese,Chinese (Simplified)"},{"Lang":"ja","Value":"英語（US）,日本語,中国語（簡体）"},{"Lang":"cn","Value":"英语（美国）,日语,简体中文"}],"Name":[{"Lang":"en","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus"},{"Lang":"ja","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus"},{"Lang":"cn","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus"}],"PrerequisiteNotes":[],"Prerequisites":{"SupportedOperatingSystems":[{"Id":"13","Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"7","Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Id":"4","Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"10","Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"1","Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Id":"3","Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Id":"6","Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"11","Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Id":"8","Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"12","Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Id":"14","Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Id":"9","Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Id":"2","Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"5","Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}]},"ProductSupportedOperatingSystems":[{"Family":"U34","SupportedOperatingSystemIDs":["13","7","4","10","1","3","11","6"]},{"Family":"U30","SupportedOperatingSystemIDs":["13","10","7","4","1","3","9","11","6","12","8","2"]},{"Family":"U32","SupportedOperatingSystemIDs":["13","4","10","14","7","1","3","9","11","6","12","8","2"]},{"Family":"U37","SupportedOperatingSystemIDs":["13","1","7","4"]},{"Family":"SPP","SupportedOperatingSystemIDs":["7","4","10","1","3","11","6","12","13"]},{"Family":"A40","SupportedOperatingSystemIDs":["10","1","6","12","13","7","4","3","11","8","2"]},{"Family":"U41","SupportedOperatingSystemIDs":["13","9","14","7","4","10","1","3","11","6","12"]},{"Family":"U33","SupportedOperatingSystemIDs":["13","7","4","10","1","3","11","6","12"]},{"Family":"U40","SupportedOperatingSystemIDs":["13","10","7","4","1","3","11","6","12"]},{"Family":"U38","SupportedOperatingSystemIDs":["13","7","4","1","12"]},{"Family":"U45","SupportedOperatingSystemIDs":["13","7","4","1","12"]},{"Family":"A41","SupportedOperatingSystemIDs":["13","7","10","1","9","14","6","12","4","3","11","8","2"]},{"Family":"U43","SupportedOperatingSystemIDs":["13","7","4","1","3","11"]},{"Family":"U44","SupportedOperatingSystemIDs":["13","7","4","10","1","3","11","6","12"]},{"Family":"U31","SupportedOperatingSystemIDs":["13","7","4","12","10","1","3","11","6"]},{"Family":"A42","SupportedOperatingSystemIDs":["7","13","4","1","10","3","9","11","6","12","8","2","5","14"]},{"Family":"A43","SupportedOperatingSystemIDs":["13","7","4","1","14","10","3","9","11","6","12","8","2","5"]},{"Family":"U48","SupportedOperatingSystemIDs":["13","4","10","6"]},{"Family":"A46","SupportedOperatingSystemIDs":["13","7","4","14","10","1","3","9","11","6","12"]},{"Family":"A47","SupportedOperatingSystemIDs":["7","4","9","14","6","10","1","3","12"]},{"Family":"A48","SupportedOperatingSystemIDs":["7","4","9","14","6","10","1","3","12"]},{"Family":"U46","SupportedOperatingSystemIDs":["13","7","4","14","10","1","3","9","11","6","12","8","2","5"]},{"Family":"U47","SupportedOperatingSystemIDs":["13","7","4","14","10","1","3","9","11","6","12"]},{"Family":"U56","SupportedOperatingSystemIDs":["10","1","3","9","11","12","8","2"]},{"Family":"U50","SupportedOperatingSystemIDs":["13","7","4","1","3","14","11","12","5","10","9","6","8","2"]},{"Family":"U61","SupportedOperatingSystemIDs":["7","4","10","14","5","1","3","9","11","6","12"]},{"Family":"U60","SupportedOperatingSystemIDs":["7","4","10","14","1","3","9","11","6","12","5"]},{"Family":"U39","SupportedOperatingSystemIDs":["13","10","1","3","14","11","12","5","4","9","6","8","2"]},{"Family":"U64","SupportedOperatingSystemIDs":["4","10","9","14","3","11","6"]},{"Family":"H08","SupportedOperatingSystemIDs":["13","4","10","6","8","2","7"]},{"Family":"H10","SupportedOperatingSystemIDs":["13","7","4","10","1","3","9","14","12","11","6","8","2","5"]}],"ReleaseDate":{"Day":"08","Hours":"16","Minutes":"38","Month":"01","Seconds":"44","Year":"2026"},"RevisionHistory":{"ReleaseNotes":[{"Enhancements":"<p>Service pack for HPE ProLiant Gen10 and 10 Plus&nbsp;2026.01.00.00 release contains components supporting HPE ProLiant and HPE Apollo Gen10 and Gen10 Plus server platforms and options.</p><p>This SPP release contains Smart Update Manager (SUM) 12.5.0 and HPE Integrated Lights-Out (iLO) 5 version 3.17.</p><p>&nbsp;</p><p>For a complete list of components included in the SPP, see the Contents Report (contents.html) packaged in the ISO or view the report on the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">SPP TechLibrary page</a> under the Quick Links tab.&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Service pack for HPE ProLiant Gen10 and 10 Plus&nbsp;2026.01.00.00 release contains components supporting HPE ProLiant and HPE Apollo Gen10 and Gen10 Plus server platforms and options.</p><p>This SPP release contains Smart Update Manager (SUM) 12.5.0 and HPE Integrated Lights-Out (iLO) 5 version 3.17.</p><p>&nbsp;</p><p>For a complete list of components included in the SPP, see the Contents Report (contents.html) packaged in the ISO or view the report on the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">SPP TechLibrary page</a> under the Quick Links tab.&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Service pack for HPE ProLiant Gen10 and 10 Plus&nbsp;2026.01.00.00 release contains components supporting HPE ProLiant and HPE Apollo Gen10 and Gen10 Plus server platforms and options.</p><p>This SPP release contains Smart Update Manager (SUM) 12.5.0 and HPE Integrated Lights-Out (iLO) 5 version 3.17.</p><p>&nbsp;</p><p>For a complete list of components included in the SPP, see the Contents Report (contents.html) packaged in the ISO or view the report on the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">SPP TechLibrary page</a> under the Quick Links tab.&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2026.01.00.00"},"SPPGeneration":[""],"SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"Version":{"Revision":"","TypeOfChange":"1","Value":"2026.01.00.00"}}],"Components":[{"ProductId":"df6ba3c2e569412ab3999b9575ddb1d8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"19400506","DateModified":"2025-03-06T07:33:30","FileList":["/CP066007_BUILD_3.data","/CP066007.vmexe64","/CP066007.vmfile","/CP066007_VMw.zip","/CP066007.xml","/payload.json","/CP066007_VMw.zip/index.xml","/CP066007_VMw.zip/vendor-index.xml","/CP066007_VMw.zip/metadata.zip","/CP066007_VMw.zip/vib20/CP066007/HPE_bootbank_CP066007_HPG6.3-1OEM.800.1.0.20613240.vib","/CP066007_VMw.zip/metadata.zip/vendor-index.xml","/CP066007_VMw.zip/metadata.zip/vmware.xml","/CP066007_VMw.zip/metadata.zip/vibs/CP066007-2964671944557029632.xml","/CP066007_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066007_HPG6.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"0c4557952434c869c0207ac2d9a87f78","Name":"CP066007.zip","Release":"2025-03-06T07:32:46","Revision":"C","SHA1Sum":"9fcf0cb698c6d7a2ed2ea572fbf015a075a59a58","SHA256Sum":"5e444f3f784500015d3688437849f391d7251799e831a01cfaf755051420c532","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP066007","Version":"HPG6.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043256.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000GWWQH","TargetGUID":"4d2340a5-3042-3430-3030-304757575148","Type":"sata"},{"Id":"MB002000GWWQF","TargetGUID":"4d2340a5-3042-3230-3030-304757575146","Type":"sata"},{"Id":"MB001000GWWQE","TargetGUID":"4d2340a5-3042-3130-3030-304757575145","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:06:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b900be4b099045c3a7fa9b0424ade33a"}]},{"ProductId":"799a5476ba934d049a4150e04e75c398","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPNTG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3230-3030-304759444e4b","Version":"HPG4"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPNTG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3430-3030-304759445044","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB002000GYDNK and MB004000GYDPD"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB002000GYDNKおよびMB004000GYDPD"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB002000GYDNK and MB004000GYDPD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp; Firmware changes aligned for FIPS code release and one assert fix</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp; Firmware changes aligned for FIPS code release and one assert fix</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp; Firmware changes aligned for FIPS code release and one assert fix</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2621905","DateModified":"2025-06-20T01:05:19","FileList":["payload.json","Seagate_CimarronBP_SCIMARBPNTG4.HPb","Seagate_CimarronBP_SCIMARBPNTG4.xml"],"MD5Sum":"a6fa0391e7335366097c9e20ac7ed6fa","Name":"Seagate_CimarronBP_SCIMARBPNTG4.fwpkg","Release":"2025-06-20T01:02:27","Revision":"","SHA1Sum":"92e09fe04033bc134c66afaad9fb56d6ec9d690a","SHA256Sum":"fb3716a3647cab1b6e97139a51176141599ca2a43a06efdabed395bc19313127","Size":"2MB","TargetGUIDs":["4d2340a5-3042-3230-3030-304759444e4b","4d2340a5-3042-3430-3030-304759445044"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB002000GYDNK and MB004000GYDPD"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MB002000GYDNKおよびMB004000GYDPD"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB002000GYDNK and MB004000GYDPD"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB002000GYDNK","TargetGUID":"4d2340a5-3042-3230-3030-304759444e4b","Type":"sata"},{"Id":"MB004000GYDPD","TargetGUID":"4d2340a5-3042-3430-3030-304759445044","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-20T00:31:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>1.Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2. Adding other logging and FW enhancements.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>1.ドライブがアサートを防ぐためにRequest Senseの前にR/Wコマンドを選択して実行する原因となった、メディアキャッシュクリーニングの中止処理のロジックバグを修正しました。<br />2. その他のログ機能とFW機能強化を追加します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>1.Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2. Adding other logging and FW enhancements.</p>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for FIPS code release and one assert fix</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for FIPS code release and one assert fix</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for FIPS code release and one assert fix</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB002000GYDNK","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB004000GYDPD","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"598a471de19b4292a91b0bdd450b8133"}]},{"ProductId":"ffbc55840f92498790e9569c6abb14d8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68&nbsp; Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update..</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68&nbsp; Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update..</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4429696","DateModified":"2025-11-15T20:09:15","FileList":["cp068646.xml","cpqsetup.exe","KACM6ALSGPK8.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"4145791837e85f7cadf553546680d7d6","Name":"cp068646.exe","Release":"2025-11-15T20:04:41","Revision":"B","SHA1Sum":"c2d5c0dff623eca4cbc4b2692e2c856362d96661","SHA256Sum":"0de0c680e1af08b3a0a0e01165b231eec2f8302a54a0e24ba379c076ca1071d1","Size":"4MB","TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"KCM6XRUL960G","TargetGUID":"002340a5-434b-364d-5852-554c39363047","Type":"nvme"},{"Id":"KCM6XRUL7T68","TargetGUID":"002340a5-434b-364d-5852-554c37543638","Type":"nvme"},{"Id":"KCM6XRUL1T92","TargetGUID":"002340a5-434b-364d-5852-554c31543932","Type":"nvme"},{"Id":"KCM6XVUL3T20","TargetGUID":"002340a5-434b-364d-5856-554c33543230","Type":"nvme"},{"Id":"KCM6XRUL3T84","TargetGUID":"002340a5-434b-364d-5852-554c33543834","Type":"nvme"},{"Id":"KCM6XVUL800G","TargetGUID":"002340a5-434b-364d-5856-554c38303047","Type":"nvme"},{"Id":"KCM6XVUL6T40","TargetGUID":"002340a5-434b-364d-5856-554c36543430","Type":"nvme"},{"Id":"KCM6XVUL1T60","TargetGUID":"002340a5-434b-364d-5856-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:16:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>リセットの問題と定期的なメンテナンスファームウェアアップデートを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"GPK8"}],"SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"40522dcb139844feadb9548f07c0d61f"}]},{"ProductId":"3771cd39413d469099d505f7db47003a","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 661SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./XXV710DA2_8p30_CFGID12p0_OEMGEN_J65979.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-158b15900253","Version":"8.30"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline Systems running a supported Microsoft Windows Operating System installed in HPE Edgeline EL8000/EL8000t chassis."},{"Lang":"ja","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline Systems running a supported Microsoft Windows Operating System installed in HPE Edgeline EL8000/EL8000t chassis."},{"Lang":"cn","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline Systems running a supported Microsoft Windows Operating System installed in HPE Edgeline EL8000/EL8000t chassis."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9885392","DateModified":"2026-01-22T02:34:13","FileList":["661SFP.cfg","BootIMG.FLB","cp070454.xml","cpqsetup.exe","FVL_25G_Adapter_VPD_MAP.txt","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","iSCSI.txt","iv.txt","nvmupdatew64e.exe","payload.json","payload_version.txt","XXV710DA2_9p20_CFGID12p0_OEMGEN.bin"],"MD5Sum":"5910630082e142d5fd0a435171cfecc3","Name":"cp070454.exe","Release":"2026-01-22T02:17:59","Revision":"A","SHA1Sum":"db4993be7b53c1f6191828fd80fac24bb7cb72de","SHA256Sum":"af44cbc044c00bea0b358ae2167d9cef325abde880e27868699950e43919016e","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-158b15900253"],"TypeOfChange":"1","Version":"9.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;</p><p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed from HPSUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed from HPSUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"},{"Lang":"cn","Value":"<p>&nbsp;</p><p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed from HPSUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Edgeline 661SFP28 NIC Firmware Pack for Microsoft Windows"},{"Lang":"ja","Value":"HPE Edgeline 661SFP28 NIC Firmware Pack for Microsoft Windows"},{"Lang":"cn","Value":"HPE Edgeline 661SFP28 NIC Firmware Pack for Microsoft Windows"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"158B","SubDev":"0253","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-158b15900253","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-22T02:15:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Latest FW 9.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Latest FW 9.20</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Latest FW 9.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.20"}],"SWKeys":[{"Name":"XXV710_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c28f2857d33846b1a33081f250a3086a"}]},{"ProductId":"605b084308a74c74a0091e855e41c6f1","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4704-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4704"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4704-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4704"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8002"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 8.0"},{"Lang":"ja","Value":"このパッケージは、VMware ESXi 8.0上でHPE Mellanox VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"}],"Files":[{"Bytes":"31712810","DateModified":"2025-10-14T14:21:37","FileList":["/CP069161.xml","/payload.json","/CP069161_VMw.zip","/CP069161.vmexe64","/CP069161.vmfile","/CP069161_VMw.zip/index.xml","/CP069161_VMw.zip/vendor-index.xml","/CP069161_VMw.zip/metadata.zip","/CP069161_VMw.zip/vib20/CP069161/HPE_bootbank_CP069161_1.0.0-8.0.0.21495797.vib","/CP069161_VMw.zip/metadata.zip/vendor-index.xml","/CP069161_VMw.zip/metadata.zip/vmware.xml","/CP069161_VMw.zip/metadata.zip/vibs/CP069161--4217876796742253925.xml","/CP069161_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069161_1.0.0-8.0.0.21495797.xml"],"MD5Sum":"19d0c6a7a45a8202369e022b9ba8283c","Name":"CP069161.zip","Release":"2025-10-14T14:23:57","Revision":"","SHA1Sum":"8710cc7d3c29e68c3eeea3b89c055e4712a617e1","SHA256Sum":"36617e20581376b58dae3803e07095a6bd803a9abb8b3aa85dd52050a7b1c8ad","Size":"30MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.6","VibList":[{"Name":"CP069161","Version":"1.0.0-8.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p>&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.<br />&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します。 <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。<br /> </p><p><strong>注記：</strong>CX5ネットワークアダプターファームウェアを16.21.1xxxまたは16.22.1xxx（またはそれ以前）から16.26.1xxx（またはそれ以降）にアップグレードするには、中間ファームウェアバージョンとして16.23.1xxxまたは16.24.1xxxまたは16.25.1xxxを使用してください。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p>&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.<br />&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 8.0"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ（ESXi 8.0）for HPE Mellanox VPI（EthernetおよびInfinibandモード）ConnectX4およびConnectX5デバイス - VMware ESXi 8.0"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"13000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T14:31:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1ポート840QSFP28アダプター)</li><li>825111-B21(HPE InfiniBand EDR/Ethernet 100Gb 2ポート840QSFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>879482-B21(HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター)</li><li>872726-B21（HPE InfiniBand EDR/Ethernet 100Gb 2ポート 841QSFP28アダプター）</li></ul><p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン12.28.2302には新機能の追加も変更もありません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302に追加された新しい修正はありません。</strong></p><p> </p><p><strong>以下の問題点がバージョン16.35.4506で修正されました。</strong></p><p> </p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.5"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.6"}],"SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"85aeeef1c2034ddc9dcbc6b49de2e41b"}]},{"ProductId":"f85aacf9018c4fbdadcdb2b9bbf03fed","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_M7450ALLHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304b584e5845","Version":"HPK4"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_M7450ALLHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3936-304b584e5a55","Version":"HPK4"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_M7450ALLHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3053-3130-3932-304b584e5846","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VR000480KXNXE,VR000960KXNZU and VS001920KXNXF"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します:"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VR000480KXNXE,VR000960KXNZU and VS001920KXNXF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp; &nbsp; &nbsp;Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付：</strong><br />     HPK4<br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPK1<br /><strong>前のファームウェアバージョン：</strong><br />     HPK1<br /><strong>機能強化/新しい機能：</strong><br />     なし<br /><strong>修正された問題:</strong><br />     ファームウェアHPK4で行われた変更と改善により、以前のファームウェアよりもPCIe VDM上のMCTPが無効になります。</p><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp; &nbsp; &nbsp;Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2385020","DateModified":"2024-10-08T11:08:14","FileList":["Micron_7450_M7450ALLHPK4.HPb","Micron_7450_M7450ALLHPK4.xml","payload.json"],"MD5Sum":"f3ad8c9c23aa5389ec6f1a0bba7f00ca","Name":"Micron_7450_M7450ALLHPK4.fwpkg","Release":"2024-10-28T00:00:00","Revision":"","SHA1Sum":"f535fc8adfc20c73163cf5e5c2d97a7455156995","SHA256Sum":"7212abcb9de057f2c3fd7c87b8fe038846875b91c34cd56ef6679a09c9452edb","Size":"2MB","TargetGUIDs":["562340a5-3052-3030-3438-304b584e5845","562340a5-3052-3030-3936-304b584e5a55","562340a5-3053-3130-3932-304b584e5846"],"TypeOfChange":"1","Version":"HPK4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":" Universal Firmware Package for Drives - VR000480KXNXE,VR000960KXNZU and VS001920KXNXF"},{"Lang":"ja","Value":" ユニバーサルファームウェアパッケージforドライブ - VR000480KXNXE、VR000960KXNZU、およびVS001920KXNXF"},{"Lang":"cn","Value":" Universal Firmware Package for Drives - VR000480KXNXE,VR000960KXNZU and VS001920KXNXF"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VR000480KXNXE","TargetGUID":"562340a5-3052-3030-3438-304b584e5845","Type":"nvme"},{"Id":"VR000960KXNZU","TargetGUID":"562340a5-3052-3030-3936-304b584e5a55","Type":"nvme"},{"Id":"VS001920KXNXF","TargetGUID":"562340a5-3053-3130-3932-304b584e5846","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-04T09:44:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>ファームウェアHPK4で行われた変更と改善により、以前のファームウェアよりも PCIe VDM上のMCTPが無効になります。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p>","Lang":"cn"}],"Version":"HPK4"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>ファームウェアHPK4で行われた変更と改善により、以前のファームウェアよりもPCIe VDM上のMCTPが無効になります。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"VR000480KXNXE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR000960KXNZU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VS001920KXNXF","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"b8cf44de46d94ae9b0f6781016022a00"}]},{"ProductId":"8adb99f8960b4849ba6664217211b8d2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルにファームウェアを提供します。VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVA"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><ul><li>Added support for SLES16.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><ul><li>Added support for SLES16.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><ul><li>Added support for SLES16.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5387119","DateModified":"2025-09-21T19:49:54","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/4ICRHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/CP068776.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068776.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068776.scexe"],"MD5Sum":"f8050a0a2dd0fc869a64c93bebb1fcaf","Name":"firmware-hdd-92d876cfea-4ICRHPK3-15.1.x86_64.rpm","Release":"2025-09-22T00:39:13","Revision":"O","SHA1Sum":"4a3ccd3b466572bc8b5004fac711e56f22567fd5","SHA256Sum":"1ae2ea17b7661bb2d2409f06a4e2f2508f3c5dcd351a7ac0230aad2502d9efcc","Size":"5MB","TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報:</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO002000KWVVC","TargetGUID":"562340a5-304f-3230-3030-304b57565643","Type":"nvme"},{"Id":"VO004000KWVUR","TargetGUID":"562340a5-304f-3430-3030-304b57565552","Type":"nvme"},{"Id":"MO001600KWVUU","TargetGUID":"4d2340a5-304f-3130-3630-304b57565555","Type":"nvme"},{"Id":"MO003200KWVUV","TargetGUID":"4d2340a5-304f-3330-3230-304b57565556","Type":"nvme"},{"Id":"MO006400KWVVA","TargetGUID":"4d2340a5-304f-3630-3430-304b57565641","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-11T10:46:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4ICRHPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"}],"SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c40a36ef0eb14c6ca2d92be35d8d3f1d"}]},{"ProductId":"1e4f77062f4d48c8906f4212d8016a76","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A48_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34015834","DateModified":"2026-01-13T00:43:16","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.00_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.00_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.00_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.00_2026_01_09-1.1/A48_4.00_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.00_2026_01_09-1.1/CP070368.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.00_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.00_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.00_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.00_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070368.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070368.scexe"],"MD5Sum":"b294792806227360f4e2875f228393cc","Name":"firmware-system-a48-4.00_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T06:35:44","Revision":"","SHA1Sum":"db038579cf6d73d8f17655e9c2757ac34e280e1d","SHA256Sum":"8cd2ac6e18c4b705a1f1dd91a24683cd6567dc82463791076946d79db1db4a49","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T06:34:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.90_10-03-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"af561872949a41e4988e41204dc31af0"}]},{"ProductId":"d54c971d2c3047569ed2e37939cd2848","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19554103","DateModified":"2025-03-06T13:56:49","FileList":["/CP065939_BUILD_2.data","/CP065939.vmexe64","/CP065939.vmfile","/CP065939_VMw.zip","/CP065939.xml","/payload.json","/CP065939_VMw.zip/index.xml","/CP065939_VMw.zip/vendor-index.xml","/CP065939_VMw.zip/metadata.zip","/CP065939_VMw.zip/vib20/CP065939/HPE_bootbank_CP065939_HPD3.2-1OEM.800.1.0.20613240.vib","/CP065939_VMw.zip/metadata.zip/vendor-index.xml","/CP065939_VMw.zip/metadata.zip/vmware.xml","/CP065939_VMw.zip/metadata.zip/vibs/CP065939-6829899646179790068.xml","/CP065939_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065939_HPD3.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"9df9827bb6d73aec3cb48ebb51ebf1f0","Name":"CP065939.zip","Release":"2025-03-06T13:55:58","Revision":"B","SHA1Sum":"5df7a56986fc7291050ffda5784d0b3fd48ba1d9","SHA256Sum":"0b92c451277d684155b1144dd6c7a2753dade3014b4bb857dfc4a011e55b4152","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"2","Version":"HPD3","VibList":[{"Name":"CP065939","Version":"HPD3.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040645.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA および MO003200JWDLBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MO003200JWDLB","TargetGUID":"4d2340a5-304f-3330-3230-304a57444c42","Type":"sas"},{"Id":"MO001600JWDLA","TargetGUID":"4d2340a5-304f-3130-3630-304a57444c41","Type":"sas"},{"Id":"EO001600JWDKR","TargetGUID":"452340a5-304f-3130-3630-304a57444b52","Type":"sas"},{"Id":"MO000800JWDKV","TargetGUID":"4d2340a5-304f-3030-3830-304a57444b56","Type":"sas"},{"Id":"EO000800JWDKQ","TargetGUID":"452340a5-304f-3030-3830-304a57444b51","Type":"sas"},{"Id":"MO000400JWDKU","TargetGUID":"4d2340a5-304f-3030-3430-304a57444b55","Type":"sas"},{"Id":"EO000400JWDKP","TargetGUID":"452340a5-304f-3030-3430-304a57444b50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:57:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、推定発効日2024年8月9日のHPE Customer Bulletin（<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>）を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c510b3b7041e47f49b7d1a76cb4bb0d0"}]},{"ProductId":"30c69f83193c4f679a84938a219df0d6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1416008","DateModified":"2025-11-16T11:12:15","FileList":["cp069531.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"MD5Sum":"14f6d7879e49e2eda8d5ac899ba1b574","Name":"cp069531.exe","Release":"2025-11-16T10:57:52","Revision":"B","SHA1Sum":"efe39f8a329b5a5d2af18b7f4a0cdc36f9641791","SHA256Sum":"39b9699c6cf1c9ce6effc19416036b1bbb9a7d8a201328a3b219573cd6da869a","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.17.63.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel iavf Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Intel iavfドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Intel iavf Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CD","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37CD15900000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-154c103c0000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:50:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、VFドライバーが無効になっているかインストールされていない場合にVMトラフィックが機能しない可能性がある問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、VFドライバーが無効になっているかインストールされていない場合にVMトラフィックが機能しない可能性がある問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"}],"SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"632a6a19bde74e7ba9fc81827ee304df"}]},{"ProductId":"3c5ca1f7884d46278989b90e474b83e1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"4551024","DateModified":"2025-11-16T12:32:13","FileList":["cp068741.xml","cpqsetup.exe","HVLAeAsseFD2.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"3cdc177c1570f0bc3bcd2050b1e56fb6","Name":"cp068741.exe","Release":"2025-11-16T12:26:43","Revision":"G","SHA1Sum":"c33b6c3f75b45be81225514353863e2932538021","SHA256Sum":"2bf5d7a2e607ddd05504feace561e49d3008b86a38b66549ec9c6433013c3730","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB006000JWKGN ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB006000JWKGN","TargetGUID":"4d2340a5-3042-3630-3030-304a574b474e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T07:16:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a832d5a21a8241718cd47976433f543c"}]},{"ProductId":"5410a19b6b464f26bd8935266bc1120d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U39_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33609511","DateModified":"2026-01-14T02:29:15","FileList":["payload.json","U39_3.62_01_09_2026.signed.flash","U39_3.62_01_09_2026.xml"],"MD5Sum":"ecfedee12c7878e131a67e697309b737","Name":"U39_3.62_01_09_2026.fwpkg","Release":"2026-01-14T02:26:01","Revision":"","SHA1Sum":"99c3f5edeb91b8776bba5910abf10cb1ae613a6d","SHA256Sum":"175baea287a944d7132f7abc9ce5fc88c23886b5e007ec3bea7bee57c088a13d","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:28:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"d1a911361fe6483282f96e6670920d8e"}]},{"ProductId":"5b36200ffa3640839369c39ca58c8134","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b584e5848","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b584e5a56","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58504141","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58504142","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b584e5844","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b584e5a51","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b584e5a52","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b584e5a54","Version":"HPS3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。VO000960KXNXD、VO001920KXNZQ、VO003840KXNZR、VO007680KXNZT、MO000800KXNXH、MO001600KXNZV、MO003200KXPAA、およびMO006400KXPAB"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; - Improvements to our out-of-band message handling to ensure robust device management capabilities<br />&nbsp;&nbsp;&nbsp; - Changes to improve our PCIe link compatibility as well as device reliability<br />&nbsp; &nbsp; -&nbsp;This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付：</strong><br />     HPS3<br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPS1<br /><strong>前のファームウェアバージョン：</strong><br />     HPS1<br /><strong>機能強化/新しい機能：</strong><br />      なし</p><p><strong>修正された問題点：</strong><br />    - 強力なデバイス管理機能を確保するためのアウトオブバンドメッセージ処理の改善<br />    - デバイス管理機能の堅牢を確保するために、アウトオブバンドメッセージの改善<br />    - このファームウェアアップデートは、システムの相互運用性を向上させ、ドライブが応答しなくなる可能性のある特定のシナリオを防止するため、推奨されます。</p><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; - Improvements to our out-of-band message handling to ensure robust device management capabilities<br />&nbsp;&nbsp;&nbsp; - Changes to improve our PCIe link compatibility as well as device reliability<br />&nbsp; &nbsp; -&nbsp;This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2390411","DateModified":"2024-05-06T09:59:15","FileList":["Micron_7450_Micron_7450_M7450ALLHPS3.HPb","Micron_7450_Micron_7450_M7450ALLHPS3.xml","payload.json"],"MD5Sum":"df9258d8fb5d6e35159b805e0cd36109","Name":"Micron_7450_Micron_7450_M7450ALLHPS3.fwpkg","Release":"2024-05-16T00:00:00","Revision":"","SHA1Sum":"31f35f3c86a40970ac7189d3c9cb92013f86ac89","SHA256Sum":"1752964c42c72ea8a32b625c1aad585371ba2f0c2870694ca45be4e296236a3c","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304b584e5848","4d2340a5-304f-3130-3630-304b584e5a56","4d2340a5-304f-3330-3230-304b58504141","4d2340a5-304f-3630-3430-304b58504142","562340a5-304f-3030-3936-304b584e5844","562340a5-304f-3130-3932-304b584e5a51","562340a5-304f-3330-3834-304b584e5a52","562340a5-304f-3730-3638-304b584e5a54"],"TypeOfChange":"1","Version":"HPS3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - VO000960KXNXD、VO001920KXNZQ、VO003840KXNZR、VO007680KXNZT、MO000800KXNXH、MO001600KXNZV、MO003200KXPAA、およびMO006400KXPAB"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO001920KXNZQ","TargetGUID":"562340a5-304f-3130-3932-304b584e5a51","Type":"nvme"},{"Id":"VO003840KXNZR","TargetGUID":"562340a5-304f-3330-3834-304b584e5a52","Type":"nvme"},{"Id":"VO007680KXNZT","TargetGUID":"562340a5-304f-3730-3638-304b584e5a54","Type":"nvme"},{"Id":"MO000800KXNXH","TargetGUID":"4d2340a5-304f-3030-3830-304b584e5848","Type":"nvme"},{"Id":"MO001600KXNZV","TargetGUID":"4d2340a5-304f-3130-3630-304b584e5a56","Type":"nvme"},{"Id":"MO003200KXPAA","TargetGUID":"4d2340a5-304f-3330-3230-304b58504141","Type":"nvme"},{"Id":"MO006400KXPAB","TargetGUID":"4d2340a5-304f-3630-3430-304b58504142","Type":"nvme"},{"Id":"VO000960KXNXD","TargetGUID":"562340a5-304f-3030-3936-304b584e5844","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-07T09:26:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improvements to our out-of-band message handling to ensure robust device management capabilities</li><li>Changes to improve our PCIe link compatibility as well as device reliability</li><li>This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>強力なデバイス管理機能を確保するためのアウトオブバンドメッセージ処理の改善</li><li>デバイス管理機能の堅牢を確保するために、アウトオブバンドメッセージの改善</li><li>このファームウェアアップデートは、システムの相互運用性を向上させ、ドライブが応答しなくなる可能性のある特定のシナリオを防止するため、推奨されます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improvements to our out-of-band message handling to ensure robust device management capabilities</li><li>Changes to improve our PCIe link compatibility as well as device reliability</li><li>This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</li></ul>","Lang":"cn"}],"Version":"HPS3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improvements to our out-of-band message handling to ensure robust device management capabilities</li><li>Changes to improve our PCIe link compatibility as well as device reliability</li><li>This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>強力なデバイス管理機能を確保するためのアウトオブバンドメッセージ処理の改善</li><li>デバイス管理機能の堅牢を確保するために、アウトオブバンドメッセージの改善</li><li>このファームウェアアップデートは、システムの相互運用性を向上させ、ドライブが応答しなくなる可能性のある特定のシナリオを防止するため、推奨されます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improvements to our out-of-band message handling to ensure robust device management capabilities</li><li>Changes to improve our PCIe link compatibility as well as device reliability</li><li>This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</li></ul>","Lang":"cn"}],"Version":"HPS3"}],"SWKeys":[{"Name":"VO000960KXNXD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXNZQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXNZR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXNZT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO000800KXNXH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXNZV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXPAA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXPAB","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"be4575b6b0d64fc097f43ac471267831"}]},{"ProductId":"2dc80c4ae4b943faadb938f8fc2b61d5","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_317.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.17"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_317.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.17"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_317.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.17"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides updated iLO firmware that can be installed directly on supported Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the Smart Update Manager."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、Smart Update Managerと一緒に使用することができます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"https://www.hpe.com/info/ilo-docs\">www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"https://www.hpe.com/info/ilo-docs\">www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"}],"Files":[{"Bytes":"33588447","DateModified":"2025-12-03T08:28:07","FileList":["ilo5_317.bin","ilo5_317.xml","payload.json","readme.txt"],"MD5Sum":"d48e9662ee7b8479350e6378a2f2de32","Name":"ilo5_317.fwpkg","Release":"2025-12-03T08:24:54","Revision":"","SHA1Sum":"ece2ecd9118dc644f9161101e81be27612530e6f","SHA256Sum":"e2ed7b4ef55ec20fe281d83a9df54daf60b3d3a9380b57fea1a394020b896d11","Size":"32MB","TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.17"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" target=\"_blank\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" target=\"_blank\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュファームウェアパッケージ - HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32801"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-09T08:47:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>There are no enhancements in the current HPE iLO 5 v3.16 release.</p>","Fixes":"<p>&bull; Fixed an issue with the backup_start event to protect the back up process from auxiliary power cycle interruptions. This fix includes the implementation of IML logging.<br />&bull; Fixed an issue with HPE iLO to display power supplies as per power supply type AC or DC.<br />&bull;&nbsp;Fixed an issue where iLO could report the network status as &ldquo;Unknown&rdquo; instead of &ldquo;OK&rdquo; on Raider platforms.</p>","Lang":"en"},{"Enhancements":"<p>現在のHPE iLO 5 v3.16リリースには機能強化はありません。</p>","Fixes":"<p>• 補助電源サイクルの中断からバックアップ プロセスを保護するためのbackup_startイベントの問題を修正しました。この修正には、IMLログの実装が含まれています。<br />• HPE iLOで電源装置を電源タイプACまたはDCに応じて表示する問題を修正しました。<br />• Raider プラットフォームでiLOがネットワークステータスを「OK」ではなく「不明」と報告する問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"<p>There are no enhancements in the current HPE iLO 5 v3.16 release.</p>","Fixes":"<p>&bull; Fixed an issue with the backup_start event to protect the back up process from auxiliary power cycle interruptions. This fix includes the implementation of IML logging.<br />&bull; Fixed an issue with HPE iLO to display power supplies as per power supply type AC or DC.<br />&bull;&nbsp;Fixed an issue where iLO could report the network status as &ldquo;Unknown&rdquo; instead of &ldquo;OK&rdquo; on Raider platforms.</p>","Lang":"cn"}],"Version":"3.16"},{"ReleaseNotes":[{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"en"},{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"ja"},{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"cn"}],"Version":"3.17"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"fea07870ce3c4a4f9091b26b3afc167f"}]},{"ProductId":"d65fb45f0327449eb7763d2d9cb7bf3e","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"28498383","DateModified":"2025-12-19T12:07:08","FileList":["/CP069051_BUILD_1.data","/CP069051.vmcfg","/CP069051.vmexe64","/CP069051.vmfile","/CP069051_VMw.zip","/CP069051.xml","/payload.json","/CP069051_VMw.zip/index.xml","/CP069051_VMw.zip/vendor-index.xml","/CP069051_VMw.zip/metadata.zip","/CP069051_VMw.zip/vib20/CP069051/HPE_bootbank_CP069051_0130.1-8.0.0.20613240.vib","/CP069051_VMw.zip/metadata.zip/vendor-index.xml","/CP069051_VMw.zip/metadata.zip/vmware.xml","/CP069051_VMw.zip/metadata.zip/vibs/CP069051-5831732177573064755.xml","/CP069051_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069051_0130.1-8.0.0.20613240.xml"],"MD5Sum":"d787c720297d21ae7478c84ab8bf7bc0","Name":"CP069051.zip","Release":"2025-12-19T12:03:49","Revision":"I","SHA1Sum":"aca96d892ae2597ab066c0beb95265e257f9d43b","SHA256Sum":"e6cb19c2a82f18800234e2a985f1ce297505941f80cb093cb912c585b9ae034e","Size":"27MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130","VibList":[{"Name":"CP069051","Version":"0130.1-8.0.0.20613240"}]}],"Installation":{"Command":"setup","CommandParams":"-t D8000 -v 0130 -i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff -i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff -l D8000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"ja","Value":"HPE D8000 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"},{"Lang":"cn","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D8000 12Gb Enclosure","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"},{"Id":"D8000 12Gb IO","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-06T08:24:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"},{"ReleaseNotes":[{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p>ESXi 9.0のサポートを追加しました</p><p>ESXi 7.0のサポートを削除しました</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"}],"SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1e9464560bd248a3b51eb190a3961008"}]},{"ProductId":"6ca4dd262131408db10af90451555128","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8002-MCX653106A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30074","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter  : HPE part numbers P23666-B21 and P23666-H21"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor HPE InfiniBand HDR/Ethernet 100Gb 2ポートQSFP56 PCIe4 x16 MCX653106A-ECATアダプター: HPE部品番号P23666-B21およびP23666-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter  : HPE part numbers P23666-B21 and P23666-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p><strong>HDR / 200GbE cables:</strong></p><ul><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><ul></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p><strong>HDR / 200GbEケーブル：</strong></p><ul><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p><strong>HDR / 200GbE cables:</strong></p><ul><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><ul></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6276754","DateModified":"2025-10-08T11:27:15","FileList":["20_43_8002-MCX653106A-ECA_HPE_Ax.pldm.signed","20_43_8002-MCX653106A-ECA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"acca313fac4bc6b052251776d5620c61","Name":"20_43_8002-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","Release":"2025-10-08T11:25:16","Revision":"","SHA1Sum":"9cff7fb489f35857b84c706daa35eebccd5d367d","SHA256Sum":"5a7fb761fa586de697bf3682fe327bcd57fcacae7a5c7f78a36ecb0d70cc1d60","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"TypeOfChange":"1","Version":"20.43.8002"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter : HPE part numbers P23666-B21 and P23666-H21"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ（FWPKG）for HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe4 x16 MCX653106A-ECATアダプター: HPE部品番号P23666-B21およびP23666-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter : HPE part numbers P23666-B21 and P23666-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-08T10:45:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"20.43.8002"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653106A-ECAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"2d415f93654b420ba4457f2e61d3f10d"}]},{"ProductId":"cc96bd351eff4426bf37f3da741a7623","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB004000GWKGV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWKGV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20603112","DateModified":"2025-03-06T16:46:27","FileList":["/CP065987_BUILD_3.data","/CP065987.vmexe64","/CP065987.vmfile","/CP065987_VMw.zip","/CP065987.xml","/payload.json","/CP065987_VMw.zip/index.xml","/CP065987_VMw.zip/vendor-index.xml","/CP065987_VMw.zip/metadata.zip","/CP065987_VMw.zip/vib20/CP065987/HPE_bootbank_CP065987_HPG1.3-1OEM.800.1.0.20613240.vib","/CP065987_VMw.zip/metadata.zip/vendor-index.xml","/CP065987_VMw.zip/metadata.zip/vmware.xml","/CP065987_VMw.zip/metadata.zip/vibs/CP065987-2652008018376451013.xml","/CP065987_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065987_HPG1.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"5cd504e016a9b599a0efd88001cfc5d1","Name":"CP065987.zip","Release":"2025-03-06T16:45:43","Revision":"K","SHA1Sum":"ed881d89631edd69c1afa5257bd5b5c0cdd76ed8","SHA256Sum":"762a7c29e6eea34db2bcb008f2c7ad3a6d91de0466b3a922aaf4a53b0a2c0db3","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065987","Version":"HPG1.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041493.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000GWKGVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000GWKGV","TargetGUID":"4d2340a5-3042-3430-3030-3047574b4756","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:34:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2e372effed5940ee9e19594f3202980c"}]},{"ProductId":"2b01702f6be343c09f8208f8aab17afb","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR216i-a_Gen10P_52.32.3-6333_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.32.3-6333"}]},"MinimumActiveVersion":"52.26.3.5487","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"HPE MR216i-a Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"ja","Value":"<p>One-buttonセキュア消去（OBSE）およびオンラインファームウェアアクティベーション（OFA）はHPE Gen10サーバーではサポートされていないため、MR Gen10 plusコントローラーはGen10サーバーでのオンラインファームウェアアップデートをサポートしません。<br />HPE Gen10サーバーにFWPKGをインストールする必要がある場合は、FWPKGをフラッシュした後に再起動が必要になることを想定してください。</p>"},{"Lang":"cn","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"}],"Files":[{"Bytes":"7514233","DateModified":"2025-08-19T11:29:13","FileList":["HPE_MR216i-a_Gen10P_52.32.3-6333_A.HPb","HPE_MR216i-a_Gen10P_52.32.3-6333_A.xml","payload.json"],"MD5Sum":"14e9cb57ca466167914e7c774d53d973","Name":"HPE_MR216i-a_Gen10P_52.32.3-6333_A.fwpkg","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"7fbea62c506c2f66e99e756a3d5a75f21f338bd0","SHA256Sum":"ca56bbc77b6e8a883957c824086581e155fc9dae146a5b6b822fc07e523e9354","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032c"],"TypeOfChange":"1","Version":"52.32.3-6333"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/connect/s/product?language=en_US&kmpmoid=7630408&tab=driversAndSoftware&driversAndSoftwareFilter=8000078\">RESTfulインターフェイスツール</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p><p>iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li></ul>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE MR216i-a Gen10 Plusトライモードコントローラー"},{"Lang":"cn","Value":"Firmware Package - HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T18:01:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfish デバイス有効化の機能強化<ul><li>Redfishボリューム変換サポート<ul><li>POST #Volume.ChangeRAIDLayout: RAIDレイアウトの変更。RAIDレイアウトの変更は、入力JSONボディにターゲットRAIDTypeとドライブのリストを提供することで実現されます。</li><li>POST #Volume.ChangeRAIDLayout: サイズ変更。ChangeRAIDLayoutを使用すると、RAIDTypeを変更せずに新しい未構成正常ドライブを追加することでボリュームのサイズを変更できます。このような場合、入力JSONボディでRAIDTypeを指定してはいけませんが、それに応じて完全なドライブリストを指定する必要があります。</li><li>PATCH Volume[CapacityBytes]: この操作は、ボリューム内に利用可能な未使用サイズがある場合にボリュームのサイズを変更するために使用されます。ここに新しいドライブを追加するスコープはありません</li><li>POST #Volume.CheckConsistency: この操作は、ボリューム上の整合性チェック操作を開始します。この操作では入力は想定されません。</li></ul></li><li>Redfish Metrics GETサポート<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount、CorrectableECCErrorCount、CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount、SAS.LossOfDwordSynchronizationCount、SAS.RunningDisparityErrorCount、PCIeErrors.CorrectableErrorCount、PCIeErrors.FatalErrorCount、PCIeErrors.NonFatalErrorCount</li><li>各カウンターは最大65535までの値を保持できます。カウンターが最大値に達しても、値はリセットされません。</li><li>ユーザーがコントローラーのNVRAMクリアまたはRedfish ResetToDefaults.ResetAllを実行すると、メトリックはクリアされます。</li></ul></li></ul></li><li>MRSAおよびstorcli工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加。<ul><li>コントローラー上に構成が存在する場合、または固定キャッシュが存在する場合、NVRAMクリア操作は許可されません。</li><li>NVRAMをクリアした後、コントローラーFWはオンラインコントローラーリセット (OCR) を実行します。何らかの理由でOCRを実行できない場合は、システムを再起動するようにユーザーに通知されます。</li><li>NVRAMクリア操作は、機能的にはRedfish ResetToDefaults.ResetAll操作と同等です。</li></ul></li><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。非ホットプラグ構成の場合、コントローラーは常に16個のベイを表示します。</li></ul>","Fixes":"<ul><li>a00143124en_usアドバイザリを修正: HPE MR Gen11 コントローラー - HPE Gen11サーバー上のMR Gen11コントローラーがIMLで\"WriteCacheDataLoss\"を生成できない場合がある</li><li>a00148035en_usアドバイザリを修正: HPE MR Gen11コントローラー - ベイとボックスのNVMeドライブの場所がワンタイムブートメニューに表示されない</li><li>Linux OSでLTOの128KBを超える読み取り/書き込み転送が失敗する問題を修正</li><li>Backup ExecがLTOで動作しない問題を修正</li><li>240個の論理ドライブが構成されている場合、サーバーのブート時にコントローラーがiLOによってドロップされる可能性がある問題を修正</li><li>ドライブを連続的に削除すると、サーバーヘルスが一時的にクリティカルを示すというまれな問題を修正</li><li>予期しないPCIConfiglinkページイベント、仮想SESデバイスへのタスク管理のタイムアウトメッセージがsnapdumpに記録される問題を修正</li><li>空のベイにスロット対応プロトコルがない問題を修正</li><li>コントローラーに接続されたLTOのリンク速度が[不明]と表示される問題を修正</li><li>Request Senseコマンドにより、サニタイズが進行中のドライブでタスク管理が実行される問題を修正。</li><li>255を超える値が使用された場合に、Redfish PATCH StorageController[ControllerRates]がランダムな値を暗黙的に設定してしまう問題を修正。</li><li>コントローラーがパススルーとして構成されているときにVMを再起動すると、誤ったコントローラーエラーイベントが記録される可能性がある問題を修正</li><li>2つのバックプレーンが同じストレージポートに接続されている場合、Redfishファブリックポートのアクティブ幅と現在の速度が間違っているという問題を修正。</li><li>再起動後にNVMeドライブのリンクステータスが失敗する可能性があるというまれな問題を修正 </li><li>複数のドライブの取り外しと挿入が短時間に行われたときにコントローラーがアサートされる可能性があるというまれな問題を修正</li><li>SATAパススルーコマンドが実行中の場合、SATAドライブのサニタイズのパーセンテージが進行しない問題を修正</li><li>NVMeドライブでサニタイズのパーセンテージが進行しない問題を修正</li><li>読み取り/書き込みコマンドと非読み取り/書き込みコマンドの耐久テストでIOタイムアウトとデバイスリセットが発生することがあるというまれな問題を修正</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"cn"}],"Version":"52.32.3-6333"},{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfish デバイス有効化の機能強化<ul><li>Redfishボリューム変換サポート<ul><li>POST #Volume.ChangeRAIDLayout: RAIDレイアウトの変更。RAIDレイアウトの変更は、入力JSONボディにターゲットRAIDTypeとドライブのリストを提供することで実現されます。</li><li>POST #Volume.ChangeRAIDLayout: サイズ変更。ChangeRAIDLayoutを使用すると、RAIDTypeを変更せずに新しい未構成正常ドライブを追加することでボリュームのサイズを変更できます。このような場合、入力JSONボディでRAIDTypeを指定してはいけませんが、それに応じて完全なドライブリストを指定する必要があります。</li><li>PATCH Volume[CapacityBytes]: この操作は、ボリューム内に利用可能な未使用サイズがある場合にボリュームのサイズを変更するために使用されます。ここに新しいドライブを追加するスコープはありません</li><li>POST #Volume.CheckConsistency: この操作は、ボリューム上の整合性チェック操作を開始します。この操作では入力は想定されません。</li></ul></li><li>Redfish Metrics GETサポート<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount、CorrectableECCErrorCount、CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount、SAS.LossOfDwordSynchronizationCount、SAS.RunningDisparityErrorCount、PCIeErrors.CorrectableErrorCount、PCIeErrors.FatalErrorCount、PCIeErrors.NonFatalErrorCount</li><li>各カウンターは最大65535までの値を保持できます。カウンターが最大値に達しても、値はリセットされません。</li><li>ユーザーがコントローラーのNVRAMクリアまたはRedfish ResetToDefaults.ResetAllを実行すると、メトリックはクリアされます。</li></ul></li></ul></li><li>MRSAおよびstorcli工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加。<ul><li>コントローラー上に構成が存在する場合、または固定キャッシュが存在する場合、NVRAMクリア操作は許可されません。</li><li>NVRAMをクリアした後、コントローラーFWはオンラインコントローラーリセット (OCR) を実行します。何らかの理由でOCRを実行できない場合は、システムを再起動するようにユーザーに通知されます。</li><li>NVRAMクリア操作は、機能的にはRedfish ResetToDefaults.ResetAll操作と同等です。</li></ul></li><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。非ホットプラグ構成の場合、コントローラーは常に16個のベイを表示します。</li></ul>","Fixes":"<ul><li>a00143124en_usアドバイザリを修正: HPE MR Gen11 コントローラー - HPE Gen11サーバー上のMR Gen11コントローラーがIMLで\"WriteCacheDataLoss\"を生成できない場合がある</li><li>a00148035en_usアドバイザリを修正: HPE MR Gen11コントローラー - ベイとボックスのNVMeドライブの場所がワンタイムブートメニューに表示されない</li><li>Linux OSでLTOの128KBを超える読み取り/書き込み転送が失敗する問題を修正</li><li>Backup ExecがLTOで動作しない問題を修正</li><li>240個の論理ドライブが構成されている場合、サーバーのブート時にコントローラーがiLOによってドロップされる可能性がある問題を修正</li><li>ドライブを連続的に削除すると、サーバーヘルスが一時的にクリティカルを示すというまれな問題を修正</li><li>予期しないPCIConfiglinkページイベント、仮想SESデバイスへのタスク管理のタイムアウトメッセージがsnapdumpに記録される問題を修正</li><li>空のベイにスロット対応プロトコルがない問題を修正</li><li>コントローラーに接続されたLTOのリンク速度が[不明]と表示される問題を修正</li><li>Request Senseコマンドにより、サニタイズが進行中のドライブでタスク管理が実行される問題を修正。</li><li>255を超える値が使用された場合に、Redfish PATCH StorageController[ControllerRates]がランダムな値を暗黙的に設定してしまう問題を修正。</li><li>コントローラーがパススルーとして構成されているときにVMを再起動すると、誤ったコントローラーエラーイベントが記録される可能性がある問題を修正</li><li>2つのバックプレーンが同じストレージポートに接続されている場合、Redfishファブリックポートのアクティブ幅と現在の速度が間違っているという問題を修正。</li><li>再起動後にNVMeドライブのリンクステータスが失敗する可能性があるというまれな問題を修正 </li><li>複数のドライブの取り外しと挿入が短時間に行われたときにコントローラーがアサートされる可能性があるというまれな問題を修正</li><li>SATAパススルーコマンドが実行中の場合、SATAドライブのサニタイズのパーセンテージが進行しない問題を修正</li><li>NVMeドライブでサニタイズのパーセンテージが進行しない問題を修正</li><li>読み取り/書き込みコマンドと非読み取り/書き込みコマンドの耐久テストでIOタイムアウトとデバイスリセットが発生することがあるというまれな問題を修正</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"cn"}],"Version":"52.32.3-6333"}],"SWKeys":[{"Name":"032C1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"e2e72b1069984e4d976cf087ff061b20"}]},{"ProductId":"1860b8cf54d04500a5555e0fcde5c087","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"235.1.164014"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"235.1.164014"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"235.1.164014"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"235.1.164014"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"235.1.164014"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under deb Linux x86_64 platforms."},{"Lang":"ja","Value":"このパッケージには、deb Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under deb Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains NVM Image version 235.1.164014&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains NVM Image version 235.1.164014&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains NVM Image version 235.1.164014&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"}],"Files":[{"Bytes":"1408244","DateModified":"2025-12-17T20:53:59","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/CP070089.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/CP070089.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070089.scexe","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070089.scexe"],"MD5Sum":"7ad9cf8999bf208024712bde5529f3c2","Name":"firmware-nic-bcm-nxe_1.25.5-1.1_amd64.deb","Release":"2025-12-18T02:49:00","Revision":"","SHA1Sum":"4924356d61a139a1025861277a9a6d36c52b3fc5","SHA256Sum":"1e8fcebabe19fa5393833113c948db869f6694448fb5ef01b7e3eef8066d50b3","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"1.25.5"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with deb installed:</strong></p><ul><li>Install the DEB as: dpkg -i &lt;deb_filename&gt;.deb. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location , to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the deb installed).</li><li>To uninstall, run: dpkg --remove &lt;deb_package_name&gt;</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware deb package&nbsp;does not update the adapter firmware. Installing the deb merely extracts the deb content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Updating firmware with deb installed:</strong></p><ul><li>Install the DEB as: dpkg -i &lt;deb_filename&gt;.deb. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location , to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the deb installed).</li><li>To uninstall, run: dpkg --remove &lt;deb_package_name&gt;</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware deb package&nbsp;does not update the adapter firmware. Installing the deb merely extracts the deb content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with deb installed:</strong></p><ul><li>Install the DEB as: dpkg -i &lt;deb_filename&gt;.deb. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location , to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the deb installed).</li><li>To uninstall, run: dpkg --remove &lt;deb_package_name&gt;</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware deb package&nbsp;does not update the adapter firmware. Installing the deb merely extracts the deb content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for deb Linux x86_64"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティfor deb Linux x86_64"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for deb Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2026-01-17T07:53:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品拡張機能により、特定の監視機能が無効になっている場合に過熱を防ぐためのセルフシャットダウン機能が有効になります。 <br />これは、もともとファームウェアバージョン223.1.135.7以降を搭載して出荷された新しいハードウェアにのみ適用され、それ以前のリビジョンでは有効になりません。</p>","Fixes":"<ul><li>この製品は、BCM5741xアダプターのアップグレード後にファームウェアバージョン詳細のアップデートに失敗し、カードが動作していないと表示されていた問題を修正します。 </li><li>この製品は、10GBASE-LR SFP+の検出に失敗し、誤ったデフォルトとリンク障害が発生していた問題を修正します。</li><li>この製品は、iLO BMCがOCP NIC上のIPを共有している場合、OSの再起動中にリンクフラップが発生していた問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"1.25.0"},{"ReleaseNotes":[{"Enhancements":"<p>BCM235_GCA2&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>BCM235_GCA2&nbsp;</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>BCM235_GCA2&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"1.25.5"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"98f7805e77a347d6a1d5b815f3e75d52"}]},{"ProductId":"19d0fae1d2d44133a57fe6d71c8af4b7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"7358774","DateModified":"2025-09-21T21:14:34","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/CP068916.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/GPM173XAHPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068916.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068916.scexe"],"MD5Sum":"307739eb3eaf258232d338f6ccb89fc8","Name":"firmware-hdd-a27c95663d-HPK6-5.1.x86_64.rpm","Release":"2025-09-22T02:02:33","Revision":"E","SHA1Sum":"632a6f9f75c5931ff2c08c4b95d8499f00294996","SHA256Sum":"d55055e32976b6c3eb8b69dd7be1ef612b87771ff92bc58feff5ecd2e11f1e9a","Size":"7MB","TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6"}],"Installation":{"Command":"CP041864.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MO001600KYDMU","TargetGUID":"4d2340a5-304f-3130-3630-304b59444d55","Type":"nvme"},{"Id":"MO006400KYDND","TargetGUID":"4d2340a5-304f-3630-3430-304b59444e44","Type":"nvme"},{"Id":"VO015360KYDNB","TargetGUID":"562340a5-304f-3531-3336-304b59444e42","Type":"nvme"},{"Id":"VO007680KYDNA","TargetGUID":"562340a5-304f-3730-3638-304b59444e41","Type":"nvme"},{"Id":"MO003200KYDNC","TargetGUID":"4d2340a5-304f-3330-3230-304b59444e43","Type":"nvme"},{"Id":"VO001920KYDMT","TargetGUID":"562340a5-304f-3130-3932-304b59444d54","Type":"nvme"},{"Id":"VO003840KYDMV","TargetGUID":"562340a5-304f-3330-3834-304b59444d56","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:57:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPK6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"HPK6"}],"SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"378e98a7adff433fa1102dd3d475f523"}]},{"ProductId":"d1014161143144dea5631e9b65f9f0d4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWJNLおよびEG002400JWJNN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"18082794","DateModified":"2025-06-14T08:35:25","FileList":["/CP067553_BUILD_2.data","/CP067553.vmexe64","/CP067553.vmfile","/CP067553_VMw.zip","/CP067553.xml","/payload.json","/CP067553_VMw.zip/index.xml","/CP067553_VMw.zip/vendor-index.xml","/CP067553_VMw.zip/metadata.zip","/CP067553_VMw.zip/vib20/CP067553/HPE_bootbank_CP067553_HPD6.2-8.0.0.20613240.vib","/CP067553_VMw.zip/metadata.zip/vendor-index.xml","/CP067553_VMw.zip/metadata.zip/vmware.xml","/CP067553_VMw.zip/metadata.zip/vibs/CP067553-5832526650412708282.xml","/CP067553_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067553_HPD6.2-8.0.0.20613240.xml"],"MD5Sum":"28c68da6932b5b77b207396849008529","Name":"CP067553.zip","Release":"2025-06-14T08:34:33","Revision":"E","SHA1Sum":"c542418cd281665dfd24d59513877e33ee85f56a","SHA256Sum":"efffe0cd74d97f6ce791d45dfd473404b036e9b3a601afad4f6f737cd4f23f6f","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP067553","Version":"HPD6.2-8.0.0.20613240"}]}],"Installation":{"Command":"CP041560.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives"},{"Lang":"ja","Value":"オンラインHDD/SDDフラッシュコンポーネント for VMware ESXi - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EG002400JWJNN","TargetGUID":"452340a5-3047-3230-3430-304a574a4e4e","Type":"sas"},{"Id":"EG001800JWJNL","TargetGUID":"452340a5-3047-3130-3830-304a574a4e4c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-11T17:20:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"06051d7daea64c1298ab526d42c02f0d"}]},{"ProductId":"cf9a5479d0b3462eb307d2e0e0608dfc","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK5</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; None</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK5</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; None</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK5</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; None</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"}],"Files":[{"Bytes":"5148364","DateModified":"2025-08-03T01:36:00","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-1.1/CP067338.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-1.1/KACM6ALFGPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067338.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067338.scexe"],"MD5Sum":"cb8146cc206f440c88bcd06d852e784d","Name":"firmware-hdd-1a541ed00d_0GPK6-1.1_amd64.deb","Release":"2025-08-03T06:28:46","Revision":"","SHA1Sum":"eebd13750be1312fcd74d094adb0ae67f76c19fa","SHA256Sum":"f5ed9664ca5974e2d47b8af5f10084e0f44bb523a39db5695a9928fa9da936cb","Size":"4MB","TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6FRUL1T92","TargetGUID":"002340a5-434b-364d-4652-554c31543932","Type":"nvme"},{"Id":"KCM6FRUL3T84","TargetGUID":"002340a5-434b-364d-4652-554c33543834","Type":"nvme"},{"Id":"KCM6FVUL3T20","TargetGUID":"002340a5-434b-364d-4656-554c33543230","Type":"nvme"},{"Id":"KCM6FVUL1T60","TargetGUID":"002340a5-434b-364d-4656-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:26:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK6"}],"SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c0a439bd7e5943eda0dce2220587ae9a"}]},{"ProductId":"da6c398c130f48f9a5a32bd3c9213a90","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4704-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4704"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4704-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4704"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8002"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains utilities and binaries for upgrading for HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Linux x86_64 platform."},{"Lang":"cn","Value":"This package contains utilities and binaries for upgrading for HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージは、Linux x86_64プラットフォーム上でHPE VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"}],"Files":[{"Bytes":"9827468","DateModified":"2025-10-12T11:41:47","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/CP069159.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/nic_fw/fw-ConnectX4-rel-12_28_4704-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/nic_fw/fw-ConnectX4-rel-12_28_4704-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/nic_fw/fw-ConnectX5-rel-16_35_8002-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/nic_fw/fw-ConnectX5-rel-16_35_8002-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069159.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069159.scexe"],"MD5Sum":"13340a9fa2a35fe39611f1d8bb2dc24f","Name":"firmware-hca-mellanox-vpi-connectx4-1.0.19-1.1.x86_64.rpm","Release":"2025-10-12T16:37:16","Revision":"","SHA1Sum":"c81e9c65cafc13860e45c3938ca9969614dbf73d","SHA256Sum":"e7b23bdbc7db8d840d0fb20f0c5c5c894bf7d91c4cfe634d51838c4113899099","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.19"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"ja","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Linux x86_64 platform"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Linux x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64)for HPE Mellanox VPI(EthernetおよびInfinibandモード)ConnectX4デバイス - Linux x86_64プラットフォーム"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T14:30:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1ポート840QSFP28アダプター)</li><li>825111-B21(HPE InfiniBand EDR/Ethernet 100Gb 2ポート840QSFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>879482-B21(HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター)</li><li>872726-B21（HPE InfiniBand EDR/Ethernet 100Gb 2ポート 841QSFP28アダプター）</li></ul><p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン12.28.2302には新機能の追加も変更もありません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302に追加された新しい修正はありません。</strong></p><p> </p><p><strong>以下の問題点がバージョン16.35.4506で修正されました。</strong></p><p> </p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.18"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.19"}],"SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"fa591683ed42453dbe23fd462a1141c2"}]},{"ProductId":"ab0976902eae4e0c8757219b825c91f8","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U30_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33614607","DateModified":"2026-01-14T06:38:20","FileList":["payload.json","U30_3.62_01_09_2026.signed.flash","U30_3.62_01_09_2026.xml"],"MD5Sum":"b28e7d1e817cbc1a3d0f683b8345af61","Name":"U30_3.62_01_09_2026.fwpkg","Release":"2026-01-14T06:35:06","Revision":"","SHA1Sum":"4f834643652f28fb2e68195ba7524f10c0927e6f","SHA256Sum":"67af6936cfafc45d3624247ed015f5794bac2c70e664af10a265651ba53a89d6","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL380 Gen10 (U30) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL380 Gen10(U30)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL380 Gen10 (U30) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-11T14:15:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"444b43a6c8054a7383b4a035742b4521"}]},{"ProductId":"71ab729e72394b149248324ae1538718","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;-&nbsp;MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;-&nbsp;MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4468160","DateModified":"2025-08-02T22:09:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-1.1/CP067388.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-1.1/TAMG08scHPDC.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067388.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067388.scexe"],"MD5Sum":"b4c08a5deb16ab05c448aa17337f833c","Name":"firmware-hdd-8a0371a425_0HPDC-1.1_amd64.deb","Release":"2025-08-03T03:02:13","Revision":"","SHA1Sum":"ffb078b4ec075395c502aeef0afbf02005a4e2db","SHA256Sum":"474f173e3ae94f3e42d0cafbabf2266c11a65d797dc7612ab03c4e7bcf18d74a","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000JWXKH Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000JWXKH Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB016000JWXKH","TargetGUID":"4d2340a5-3042-3631-3030-304a57584b48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:28:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPDC"}],"SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c2a73f8d43b0403798a1a35e33fa8599"}]},{"ProductId":"6c76dfc1e26441a48559e0f1bee2891e","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5121296","DateModified":"2025-12-11T15:01:22","FileList":["Config.xml","cp070011.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Tormore-Release-2.74-build-001.bin","VDUFlash.dll"],"MD5Sum":"8e5fceb983bed1e266af67ecd9dd2453","Name":"cp070011.exe","Release":"2025-12-11T14:59:33","Revision":"V","SHA1Sum":"623983352f95a23ab0658100d24feeac4cb150b0","SHA256Sum":"49f3d35adfae8d3fe9fdf7eb142fa74d61ab2166b1c85420b2f710860267e19b","Size":"4MB","TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/tD6020 /v2.74 /iTormore-Release-2.74-build-001.bin /lD6020.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp; &nbsp; &nbsp; &nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong>&nbsp;&nbsp;</p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES:&nbsp;</strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong>&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275932/20-D6020-Gen10RN274W_ED21.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp; &nbsp; &nbsp; &nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong>&nbsp;&nbsp;</p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES:&nbsp;</strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong>&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275932/20-D6020-Gen10RN274W_ED21.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp; &nbsp; &nbsp; &nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong>&nbsp;&nbsp;</p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES:&nbsp;</strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong>&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275932/20-D6020-Gen10RN274W_ED21.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"cn","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"ja","Value":"HPE D6020 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2"},"SupportedDevices":[{"Id":"D6020","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-09T10:26:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li>gSEPモデルとSESデータベース内の温度センサーロジック</li><li>IOMが引き出されたときに、残っているIOMが正しくない異常温度を報告する</li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275932/20-D6020-Gen10RN274W_ED21.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275932/20-D6020-Gen10RN274W_ED21.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275932/20-D6020-Gen10RN274W_ED21.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"}],"SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"84d057a1e5e94d29a1ab371c43d77369"}]},{"ProductId":"22b29694299c4b27b67b3dde603d40b0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5482418","DateModified":"2025-11-11T08:45:26","FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-qla2xxx/qla2xxx.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"MD5Sum":"ee7e5f6f2aed57576140e218f00ed4cd","Name":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","Release":"2025-11-11T08:40:18","Revision":"","SHA1Sum":"6d538dd6746f3bad890fc8aadacf3fb2fd6c005b","SHA256Sum":"2f5df729a0fc4e88b7cd70506262ad55b195a724263e8da242c1ea7487ef7639","Size":"5MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.15.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k5.14.21_150400.22-1.sles16sp0.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k5.14.21_150400.22-1.sles16sp0.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k5.14.21_150400.22-1.sles16sp0.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-23T05:00:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.15.00-k1"}],"SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ab6c65b0ce4b49bca8e05fdc25ac1fe0"}]},{"ProductId":"a6447acbde7f4368991a3df1503f91e8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB008000GWRTC"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWRTC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20383030","DateModified":"2025-03-07T06:42:59","FileList":["/CP065990_BUILD_4.data","/CP065990.vmexe64","/CP065990.vmfile","/CP065990_VMw.zip","/CP065990.xml","/payload.json","/CP065990_VMw.zip/index.xml","/CP065990_VMw.zip/vendor-index.xml","/CP065990_VMw.zip/metadata.zip","/CP065990_VMw.zip/vib20/CP065990/HPE_bootbank_CP065990_HPG1.4-1OEM.800.1.0.20613240.vib","/CP065990_VMw.zip/metadata.zip/vendor-index.xml","/CP065990_VMw.zip/metadata.zip/vmware.xml","/CP065990_VMw.zip/metadata.zip/vibs/CP065990--8605900652559021075.xml","/CP065990_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065990_HPG1.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"959d6dc9d6fdbef08b68c47c0bc2836d","Name":"CP065990.zip","Release":"2025-03-07T06:42:05","Revision":"K","SHA1Sum":"7df7484743fbfe9fda1169a0c5a84f68aa19093b","SHA256Sum":"899dcae4446c070c623988d1103c495ad3944b656e6566425503e76ef55b4663","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065990","Version":"HPG1.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041481.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000GWRTCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000GWRTC","TargetGUID":"4d2340a5-3042-3830-3030-304757525443","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:08:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b4d49336f3f94c119afb40b5f43eca2c"}]},{"ProductId":"4eb73551b4784537817e4ada8a1d49b5","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.54 (01/09/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.54 (01/09/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34058609","DateModified":"2026-01-12T01:13:42","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.54_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.54_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.54_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.54_2026_01_09-1.1/CP070260.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.54_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.54_2026_01_09-1.1/U46_2.54_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.54_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.54_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.54_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070260.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070260.scexe"],"MD5Sum":"7f0c8766ff089385e5cdcb1a0b738513","Name":"firmware-system-u46-2.54_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-12T07:03:05","Revision":"","SHA1Sum":"5e1df19e461360210ce8b94defbc0b1bbe1e489f","SHA256Sum":"7cd8a9f7933a9b61328659c438e667b67d98f864f50b0dc987483b953484968d","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL360/DL380 Gen10 Plus（U46）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:57:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Whitley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.802（2.50_07_24_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b2cb8d1cc3a04c0ea1356c190738f95e"}]},{"ProductId":"0134d053d49b43b1add04e5a51f6ff18","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_4p90_PLDMoMCTP_80020EF6.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"4.90"}]},"MinimumActiveVersion":"4.20","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter</td><td>80020EF6</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter</td><td>80020EF6</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter</td><td>80020EF6</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"}],"Files":[{"Bytes":"10526362","DateModified":"2025-11-12T12:57:17","FileList":["HPE_E810_XXVDA2_SD_4p90_PLDMoMCTP_80020EF6.HPb","HPE_E810_XXVDA2_SD_4p90_PLDMoMCTP_80020EF6.xml","payload.json"],"MD5Sum":"564805d6cbb5e66267ef5577538e1c9a","Name":"HPE_E810_XXVDA2_SD_4p90_PLDMoMCTP_80020EF6.fwpkg","Release":"2025-11-12T12:54:04","Revision":"B","SHA1Sum":"9e350e8dcaf0e4ff68cbf5a0284400ece887bc4f","SHA256Sum":"671c4059dc51e008a823ef90661b89f610f13fe917aff6a6698f9ef87d2332c7","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860003"],"TypeOfChange":"1","Version":"4.90"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-12T09:38:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"},{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"}],"SWKeys":[{"Name":"INTEL_E810_XXV2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"4a33e9a012cf43b0b4d081cb20efe851"}]},{"ProductId":"703e98acf33d484a9d2825573e86e8c0","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U38_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33609506","DateModified":"2026-01-12T06:47:50","FileList":["payload.json","U38_3.62_01_09_2026.signed.flash","U38_3.62_01_09_2026.xml"],"MD5Sum":"9c639fa39f36fe93f3ea9e72e2e3d09d","Name":"U38_3.62_01_09_2026.fwpkg","Release":"2026-01-12T06:44:33","Revision":"","SHA1Sum":"85dcde7d3991b767edeb71f02cf65c2df7df9103","SHA256Sum":"f331eb36b894dd86b76484cccb53849da3d9894d988482c4f04505f00e229324","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:41:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"6cf3611460fb4de68af31feb6fe318b2"}]},{"ProductId":"C8510","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.2.537.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"cn","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.2.537.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"ja","Value":"HPE Storageファイバーチャネル（FC）アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター（HBA）ドライバーを提供する、バージョン14.2.537.0 のEmulex Storportドライバーfor Extended Systemが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4376776","DateModified":"2026-01-05T06:43:21","FileList":["cp066306.xml","cpqsetup.exe","elxdrvr-fc-14.2.537.0-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"MD5Sum":"efdfece3787935de5984f0b099ba4f1c","Name":"cp066306.exe","Release":"2026-01-05T06:41:50","Revision":"d","SHA1Sum":"27c18ab79f74c209d1f2ec96fef58d9df6e93ee2","SHA256Sum":"0aebf4ae195cd7196349c84668d595f91b3304b5f6dfa43d88c6056461bcfa36","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.2.537.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>［インストール］ボタンをクリックして、インストールを開始します。</p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2016"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T12:12:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2016</p><p>&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.2.537.0にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2016</p><p> </p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2016</p><p>&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"14.2.537.0"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2016</p><p>&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2016</p><p>&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2016</p><p>&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"14.2.537.0"}],"SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d4821d1767e84242b8aa47442f6595fe"}]},{"ProductId":"110c3bd2bca349b2ba7b9fec9e58ee8d","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.35.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.35.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.35.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.35.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under Linux x86_64 platform."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v20.35.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>BCM 5719 1GbE 4p BASE-T Adptr</td><td><p>1.64</p></td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T OCP3 Adptr</td><td>1.64</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T LOM Adptr</td><td>1.64</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>BCM 5720 1GbE 2p BASE-T LOM Adptr</td><td>1.43</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains combo image v20.35.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>BCM 5719 1GbE 4p BASE-T Adptr</td><td><p>1.64</p></td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T OCP3 Adptr</td><td>1.64</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T LOM Adptr</td><td>1.64</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>BCM 5720 1GbE 2p BASE-T LOM Adptr</td><td>1.43</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains combo image v20.35.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>BCM 5719 1GbE 4p BASE-T Adptr</td><td><p>1.64</p></td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T OCP3 Adptr</td><td>1.64</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T LOM Adptr</td><td>1.64</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>BCM 5720 1GbE 2p BASE-T LOM Adptr</td><td>1.43</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr></tbody></table>"}],"Files":[{"Bytes":"5913300","DateModified":"2025-11-25T01:02:26","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/CP069005.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/CP069005.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/nic_fw/BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/nic_fw/BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/nic_fw/BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/nic_fw/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.42.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069005.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069005.scexe"],"MD5Sum":"efda5dc8258e11883ae8326e669d30a6","Name":"firmware-nic-bcm-open-2.42.0-1.1.x86_64.rpm","Release":"2025-11-25T06:52:25","Revision":"","SHA1Sum":"cfaa0dc2e607f9978a3a3cc58b3af8c1ce6f3c51","SHA256Sum":"de888bb824e774ff0b221857ddd65a56721834312e54fea718a1b3d192c8952f","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"2.42.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p><ul><li>ファームウェアrpmパッケージをインストールします。<br /><em>> rpm -ivh <rpm_filename>.rpm </em></li><li>ファイルを抽出する場所を確認します。<br /><em>> rpm -qlp <rpm_filename>.rpm</em></li><li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li></ul><p> </p><p><strong><em>追加情報：</em></strong></p><ul><li>詳細情報はCPxxxxxx.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCPxxxxxx.logに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T05:34:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"2.41.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed<br />&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"2.42.0"}],"SWKeys":[{"Name":"BCM_OPEN","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U47","Model":"HPE ProLiant DX220n Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DX380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DX325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DX360 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03030202","Model":"HPE Compute Scale-up Server 3250"},{"Family":"03020102","Model":"HPE Superdome Flex 2"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"677f3af9d2954ecd965a37466bfc142d"}]},{"ProductId":"df57af7543b34ffbb722ca05255bf445","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM3 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM3_1.24_G.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901503000000","Version":"1.24"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains PLDM firmware for UBM3 storage backplanes."},{"Lang":"ja","Value":"このファームウェアパッケージには、UBM3ストレージバックプレーンのPLDMファームウェアが含まれています。"},{"Lang":"cn","Value":"This firmware package contains PLDM firmware for UBM3 storage backplanes."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"63221","DateModified":"2024-09-13T04:37:23","FileList":["HPE_UBM3_1.24_G.HPb","HPE_UBM3_1.24_G.xml","payload.json"],"MD5Sum":"7575dae1c6784d476f014d39a8bcfea3","Name":"HPE_UBM3_1.24_G.fwpkg","Release":"2024-09-13T04:33:04","Revision":"G","SHA1Sum":"050a05cd30e23620f120d6a3924f44b93cc84514","SHA256Sum":"55b03510c024198f628ac042d3a19bbcb847377ff5e6be951bd6b1e516eb36f7","Size":"61KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901503000000"],"TypeOfChange":"1","Version":"1.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"InstallationNotes":[],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - UBM3 Backplane PIC PLDM Firmware for Gen10 and Gen10 Plus and Gen11 servers usage"},{"Lang":"ja","Value":"ファームウェアパッケージ - Gen10、Gen10 Plus、およびGen11サーバーで使用するためのUBM3バックプレーンPIC PLDMファームウェア"},{"Lang":"cn","Value":"Firmware Package - UBM3 Backplane PIC PLDM Firmware for Gen10 and Gen10 Plus and Gen11 servers usage"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901503000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-04-04T09:55:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support new ML110 and DL560 Gen11 servers</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>新しいML110およびDL560 Gen11サーバーのサポート</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new ML110 and DL560 Gen11 servers</p>","Fixes":"","Lang":"cn"}],"Version":"1.24"},{"ReleaseNotes":[{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.24"}],"SWKeys":[{"Name":"UBM3PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant DL360 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant DL380 Gen12 Server"},{"Family":"","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant ML350 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"bc8e3b1eb8804b47acb76ad46bb94011"}]},{"ProductId":"a00e6ed1db904ebf80004d7820172e46","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"ja","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"cn","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 10."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1179852","DateModified":"2025-09-15T16:13:33","FileList":["./etc/depmod.d/kmod-ice.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.49.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/ice/ice.ko","./usr/share/doc/kmod-ice","./usr/share/doc/kmod-ice/COPYING","./usr/share/doc/kmod-ice/README","./usr/share/doc/kmod-ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"MD5Sum":"561cd6c8f125dc0c742c037f26ced7d6","Name":"kmod-ice-2.3.10-1.rhel10u0.x86_64.rpm","Release":"2025-09-15T16:09:04","Revision":"","SHA1Sum":"83279410d9937dd31504d427647abb56c062a7eb","SHA256Sum":"7cd93263cbdd28d01bc1efdc0245aca8899eb0c9de970200165e577c90824b86","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.3.10-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Intel ice Drivers for Red Hat Enterprise Linux 10"},{"Lang":"ja","Value":"Intel ice Drivers for Red Hat Enterprise Linux 10"},{"Lang":"cn","Value":"Intel ice Drivers for Red Hat Enterprise Linux 10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"},{"Dev":"12D3","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-12d380860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-22T08:08:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Red Hat Enterprise Server 10をサポートするための初回リリースです。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"cn"}],"Version":"1.17.8-1"},{"ReleaseNotes":[{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.3.10-1"}],"SWKeys":[{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fe7f5d92134d4c4aa083c5e202d97d20"}]},{"ProductId":"6ee949809c8346d9b5134787ab827a8a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKLおよび、MB018000JYDKN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6230844","DateModified":"2025-09-17T12:15:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/CP068839.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/SHPEEVSBPSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068839.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068839.scexe"],"MD5Sum":"d814104ab15932ad8ec553c08b2a159f","Name":"firmware-hdd-8173816d98-HPD6-3.1.x86_64.rpm","Release":"2025-09-17T17:05:05","Revision":"C","SHA1Sum":"260cf2a3959d61cec6498d499d1382d889522436","SHA256Sum":"3db0946d793f8aa938f3a7d7a88b95b4f5f5ea92a9944e5efd0fe3566e58d84a","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKL、およびMB018000JYDKNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000JYDKK","TargetGUID":"4d2340a5-3042-3031-3030-304a59444b4b","Type":"sas"},{"Id":"MB012000JYCJF","TargetGUID":"4d2340a5-3042-3231-3030-304a59434a46","Type":"sas"},{"Id":"MB014000JYCJV","TargetGUID":"4d2340a5-3042-3431-3030-304a59434a56","Type":"sas"},{"Id":"MB016000JYDKL","TargetGUID":"4d2340a5-3042-3631-3030-304a59444b4c","Type":"sas"},{"Id":"MB018000JYDKN","TargetGUID":"4d2340a5-3042-3831-3030-304a59444b4e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T17:56:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブファームウェアが強化され、Primera 600 LFFエンクロージャー内の一部のバックアップドライブで予期しない電源喪失がまれに発生する可能性が低減しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul>","Lang":"cn"}],"Version":"HPD6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f94eb54b3b1c4a1da2fcfa19d0ece105"}]},{"ProductId":"321dd379dd1a436ab919b4529b332ece","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U43_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.72 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9250248","DateModified":"2026-01-14T01:38:18","FileList":["cp070182.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U43_3.72_01_09_2026.signed.flash"],"MD5Sum":"2270c80f4550bdde297f45c4e6fb3866","Name":"cp070182.exe","Release":"2026-01-14T01:36:05","Revision":"","SHA1Sum":"f1d1fbb9a6fb99da9b7cdbe562548c4cf6124b0c","SHA256Sum":"a5a41f47b413f0692a76f7f2ae65277deb68cf80767361b63164b88d5202205a","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.72_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"ja","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T09:30:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.103と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.70_08-08-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_01-09-2026"}],"SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"e00cbb21eadc48ea811fbfcdec36db33"}]},{"ProductId":"aedaa041caed4345872545de3f1efa40","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM1000JFJTH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000JFJTH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;Firmware addresses a hot plug reporting concern</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;Firmware addresses a hot plug reporting concern</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5698691","DateModified":"2025-09-21T22:24:41","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1/CP068935.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1/SAVGNSD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068935.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068935.scexe"],"MD5Sum":"96588048201ff494b5fca3ccbe4e5c02","Name":"firmware-hdd-fa46c607d6-HPD5-7.1.x86_64.rpm","Release":"2025-09-22T03:14:10","Revision":"G","SHA1Sum":"0e59e03e787ecc7663a589352a5af9fbe871e3fd","SHA256Sum":"43b5b884a5988e592d7c1c27620d3329e24a976876a7ebd08a8a907a12042183","Size":"5MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a464a5448"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MM1000JFJTH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- MM1000JFJTHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM1000JFJTH","TargetGUID":"002340a5-4d00-314d-3030-304a464a5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:17:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MM1000JFJTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b47b01f6dc454b40bb37c8e853ce5612"}]},{"ProductId":"f14326f2e6af456689e2c8b0aa9341c7","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H08","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H08_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000221","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33587371","DateModified":"2026-01-12T03:38:18","FileList":["H08_3.62_01_09_2026.signed.flash","H08_3.62_01_09_2026.xml","payload.json"],"MD5Sum":"76f1f08040efd6eb3c95d9c8be031319","Name":"H08_3.62_01_09_2026.fwpkg","Release":"2026-01-12T03:34:28","Revision":"","SHA1Sum":"7e3683518b60eb64ccb019d9160ffa6383ef3f15","SHA256Sum":"d52a1d242308b01d27962b111d8185c3c609e4c801b0d4e1ff7d8885c5e8fe84","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant e910/e910t Server Blade (H08)"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ-HPE ProLiant e910/e910tサーバーブレード（H08）"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant e910/e910t Server Blade (H08)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:34:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"H08","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"e80e817902e74a5e9d929bb6456254e2"}]},{"ProductId":"b94490ecb4854ca6989ed2491e061c4b","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>Support FIPS enable mode.</p><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：<br />     </strong>サプリメンタルアップデート / オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーファームウェア</p><p><strong>リリースバージョンおよび/または日付:</strong><br />     NA<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     NA<br /><br /><strong>前のファームウェアバージョン：</strong><br />     NA<br /><br /><strong>ファームウェアの依存関係:</strong><br />     なし<br /><br /><strong>機能強化/新しい機能：</strong></p><p>FIPS有効化モードをサポートします。</p><p><strong>修正された問題点：</strong></p><p><strong>     </strong>なし</p><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>Support FIPS enable mode.</p><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5069410","DateModified":"2025-09-17T03:39:53","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/CP068824.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/Capitola-Release-1.27.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068824.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068824.scexe"],"MD5Sum":"02937cd57af28f9ae6c3cfb9363ebc9b","Name":"firmware-smartarray-7b5e8400dd-1.27-6.1.x86_64.rpm","Release":"2025-09-17T08:19:28","Revision":"F","SHA1Sum":"131505ac84428aeb7be6742d622f1c3db69a4718","SHA256Sum":"511f2f81e35f78454da2a2142e130ea88428529872786bb6dac59bfcf415e2ec","Size":"4MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"Installation":{"Command":"CP068824.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key&nbsp;Utility for Windows</u></a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>次のコマンドを使用してファームウェアrpmをインストールします：  rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em> <rpm_filename>  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します</li><li>CPXXXXXX.scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-smartarray-7b5e8400dd-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'にある./CPXXXXXX.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*'にある<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em> ('.rpm'拡張子の付いていないrpmファイル名) を実行します。</li></ul><p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id  </em>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-7b5e8400dd-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong><em>追加情報:</em></strong></p><p>ファームウェアrpmパッケージのインストール (rpm -ivh) は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p> </p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong></p><p><strong>オフライン：</strong></p><ul><li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>USB Key Utility for Windows</u></a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/SPPxxxxxxx/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートに必要なファームウェアを/SPPxxxxxxx/packagesディレクトリにコピーします。</li><li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key&nbsp;Utility for Windows</u></a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Plus Backplane Expander FW"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE Apollo 2000 Gen10 PlusバックプレーンエキスパンダーFW"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Id":"Apollon2800Gen10Plus","TargetGUID":"","Type":"agp"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-10-16T06:23:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.27"},{"ReleaseNotes":[{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"cn"}],"Version":"1.27"}],"SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"81f6023a6657428ba79e3359d882e95f"}]},{"ProductId":"b75caf763a204707bef1840fcde5be6a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"This component provides the driver for the Microchip/Microsemi PCIe Gen 4 Switch."},{"Lang":"ja","Value":"このコンポーネントは、Microchip/Microsemi PCIe Gen4スイッチのドライバーを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"575896","DateModified":"2025-11-18T07:31:15","FileList":["cp062283.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"MD5Sum":"b67ad24b2b7cacb52ee7ddf8df3e2bc2","Name":"cp062283.exe","Release":"2025-11-18T07:29:43","Revision":"C","SHA1Sum":"03cb53f778f555f25c0e1ff6e170779708406c66","SHA256Sum":"ba00e35789e7eb8272ff04131763e9c8b7f798aa3c322ba9a2ea09a9c74c6a3a","Size":"562KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"TypeOfChange":"0","Version":"1.0.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.<br />Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.<br />Click the &quot;Install&quot; button to perform the driver installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<br />インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。<br />インストールボタンをクリックしてドライバーインストールを実行します。</p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"Microsoft Windows Server 2022用のSwitchtec PCIeスイッチ管理ドライバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"100"},"SupportedDevices":[{"Dev":"4000","SubDev":"4000","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-400011f84000","Type":"pci","Ven":"11F8"},{"Dev":"4052","SubDev":"4052","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-405211f84052","Type":"pci","Ven":"11F8"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-08-16T10:12:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SBOM要件をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.0"}],"SWKeys":[{"Name":"Switchtec.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"07a6f72217b54f3fa879777aa74068af"}]},{"ProductId":"81cb1e1fa07441fc9994562f591c5c30","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8318909","DateModified":"2025-07-16T06:12:05","FileList":["./etc/depmod.d/bnx2.conf","./etc/depmod.d/bnx2f.conf","./etc/depmod.d/bnx2i.conf","./etc/depmod.d/bnx2x.conf","./etc/depmod.d/cnic.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"MD5Sum":"39aac4852660b9f8fd7555a92b813db1","Name":"kmod-netxtreme2-7.15.25-1.rhel9u5.x86_64.rpm","Release":"2025-07-16T05:46:12","Revision":"","SHA1Sum":"9c2ec75d246004eae81a137912ddcaf2f5460919","SHA256Sum":"28c8b48c1863f9c78c1af85ad2b6cbffbded6149b7ce37a1dc0c3cd55c5fcd8e","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"TypeOfChange":"1","Version":"7.15.25-9"},{"Bytes":"8863497","DateModified":"2025-07-16T06:18:10","FileList":["./etc/depmod.d/bnx2.conf","./etc/depmod.d/bnx2f.conf","./etc/depmod.d/bnx2i.conf","./etc/depmod.d/bnx2x.conf","./etc/depmod.d/cnic.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"MD5Sum":"7eaf3c372cb2d63bcc350e39fcdfa658","Name":"kmod-netxtreme2-7.15.25-9.rhel9u6.x86_64.rpm","Release":"2025-07-16T05:46:12","Revision":"","SHA1Sum":"e8cc990c39b664398eff6daf04ed8e1c679d6148","SHA256Sum":"adc1e3ca427e9ed20046cf304bec27a0d94a79b71b01f21723a1855d22a51ef1","Size":"8MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"TypeOfChange":"1","Version":"7.15.25-9"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1933","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1933","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"1917","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ad103c1917","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"3382","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c3382","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-16T03:39:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在Red Hat Enterprise Linux 9.5をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"7.15.24-5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"7.15.25-9"}],"SWKeys":[{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a37f275906d742b1a7bfb6ca8463a9d7"}]},{"ProductId":"1d4bdf01ac864288af51e73784711598","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."},{"Lang":"ja","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."},{"Lang":"cn","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"}],"Files":[{"Bytes":"1694955","DateModified":"2025-10-22T08:38:01","FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/02","./usr/lib/.build-id/02/b58583a9dd521377f8dba0f5051ea0c988531d","./usr/lib/.build-id/1a","./usr/lib/.build-id/1a/9e884513c15d2c13eed70e7608d7a004986763","./usr/lib/.build-id/1c","./usr/lib/.build-id/1c/413ec070b71247d1ee9e303da92553ca55038b","./usr/lib/.build-id/1d","./usr/lib/.build-id/1d/10547d8cb4e1989547bc969c5712bf9c80107d","./usr/lib/.build-id/20","./usr/lib/.build-id/20/03860090ccbc425ca122158465c2bf73790d79","./usr/lib/.build-id/20/a091ae5046c3ab9bbd39f135ec7138e6d061d3","./usr/lib/.build-id/25","./usr/lib/.build-id/25/8edbd41398ceb08e3b7a9dae547d1f3cff0b80","./usr/lib/.build-id/49","./usr/lib/.build-id/49/be876b4b53d7eacb462928acf0e289fd4055dc","./usr/lib/.build-id/5c","./usr/lib/.build-id/5c/03426124d1cab4be4a00c97f8299e5708b015e","./usr/lib/.build-id/62","./usr/lib/.build-id/62/6636a3b1bd9b114d9d6e412d279f87681e4ce7","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/0f69a291461084791a1b65d820c68779eef43e","./usr/lib/.build-id/74","./usr/lib/.build-id/74/97bd378f398e1aa328705532572a63dd1bb85e","./usr/lib/.build-id/83","./usr/lib/.build-id/83/736081f223be0b1814d2574e2dcaec6826d35b","./usr/lib/.build-id/9f","./usr/lib/.build-id/9f/903b6f4d9322f49fe947d02659a4f0cef68129","./usr/lib/.build-id/af","./usr/lib/.build-id/af/09ff64b55b88e8ac92c47f155b37657f78995f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/dc6849e7235d6527524bd970cbc48c2c23846d","./usr/lib/.build-id/cd","./usr/lib/.build-id/cd/56fa708c712a04a0badd05d848478cc12b0392","./usr/lib/.build-id/cd/daf07e91b34f7fee88c32ab063a189fcc97dc9","./usr/lib/.build-id/d2","./usr/lib/.build-id/d2/177635370dd38d098abbdc467d8163cbb3ac86","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/6ea5f409c2d849fd25d868e453b6c5d204c2f7","./usr/lib/.build-id/e6","./usr/lib/.build-id/e6/17ec90a4c9416b43610c60d6710c920d0be433","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.3.58.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.58.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.58.0","./usr/lib64/libibverbs/libmlx5-rdmav57.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.58.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.25.58.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.58.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/mlnx-ofa_kernel","./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/perftest","./usr/share/doc/perftest/COPYING","./usr/share/doc/perftest/README","./usr/share/doc/perftest/runme","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"MD5Sum":"160f81c6ae5744b7671b09bdb55ea85d","Name":"mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm","Release":"2025-10-22T06:56:34","Revision":"","SHA1Sum":"07435f8fb115618c4df077dd2079435d00835a92","SHA256Sum":"8957683c943cc1e9a15e1fc522124746212c6ac4dbb69b33cd4177763cac86e2","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"25.07-0.9.7.0"},{"Bytes":"2733306","DateModified":"2025-10-22T08:32:55","FileList":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-testmod.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/fwctl.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"MD5Sum":"faa8538dc7a67b8bb138c9a4705b8ff9","Name":"kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm","Release":"2025-10-22T06:56:34","Revision":"","SHA1Sum":"7879e1036167512ae08a2d919b08bb890bf57c70","SHA256Sum":"1da13c059cfb30cfc1758e1ec65cdadc0a912a4d74a2947280ba30b29c2907ee","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"25.07-0.9.7.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"Name":"Linux","Value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"Name":"Linux","Value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"Name":"Linux","Value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"Name":"Linux","Value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25-07&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br /><br />To install or upgrade the driver:<br />If using kernel version 6.12.0-55.9.1.el10.x86_64&nbsp;or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25-07&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br /><br />To install or upgrade the driver:<br />If using kernel version 6.12.0-55.9.1.el10.x86_64&nbsp;or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25-07&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br /><br />To install or upgrade the driver:<br />If using kernel version 6.12.0-55.9.1.el10.x86_64&nbsp;or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel10u0.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for Red Hat Enterprise Linux 10 Update 0 (x86_64)"},{"Lang":"ja","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for Red Hat Enterprise Linux 10 Update 0 (x86_64)"},{"Lang":"cn","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for Red Hat Enterprise Linux 10 Update 0 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"1023","SubDev":"0002","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102315b30002","Type":"pci","Ven":"15B3"},{"Dev":"1023","SubDev":"0006","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102315b30006","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1021","SubDev":"0073","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30073","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0086","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30086","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30074","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0085","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30085","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-07T12:13:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.04-0.6.1.1:</strong></p><ul><li>Trust Lockdown Health Syndrome: Added a new health syndrome for trust lockdown and expose the CRR bit in the health buffer. When the CRR bit is set, it indicates that the syndrome requires a cold reset for recovery.</li><li>A Single PTP Device per Hardware Clock: PHC is typically shared across multiple functions. Currently, the driver creates a separate PTP device for each network interface sharing the same PHC, resulting in redundancy and added complexity. To address this, a single PTP device is now created to represent the shared PHC when operating in real-time mode.</li><li>Log IB State Transitions: Enhanced visibility into IB device state transitions by adding log messages to the kernel log (dmesg). Each time an IB device changes state, a corresponding message will be logged. For example: &quot;mlx5_0: Port: 1 Link DOWN&quot;.</li><li>Optional-counters Binding Support and New Packets/bytes Counters: Previously, optional counters were available only on a per-link basis. This release introduces the ability to bind optional counters to a specific counter object, enabling users to track optional counters across a specific QP group. Support is provided for both automatic and manual binding modes. In both cases, the optional counters that are bound to the QP are those currently configured on the link at the time of binding. Additionally, four new optional counters that track RDMA ingress and egress traffic are introduced: rdma_tx_bytes; rdma_tx_packets; rdma_rx_bytes; rdma_rx_packets. This functionality is exposed to users via the iproute2 package, which must be updated to support this feature.</li><li>User CAPability (UCAP) API: The User CAPability (UCAP) API introduces a mechanism for creating user contexts with specific firmware privileges. It offers fine-grained control over firmware features by exposing each capability as a character device with root-level read-write access. Root processes can grant users these privileges by allowing access to the corresponding character devices. When a user context is created using a UCAP file descriptor, it inherits the associated privileges. For mlx5, two UCAP character devices are provided, and any user context opened with at least one of them is treated as privileged. To guarantee the execution of privileged commands, non-privileged commands are restricted when a privileged user is active on the device.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.04-0.6.1.1:</strong></p><ul><li>Buffer initialization became a performance bottleneck during the allocation of large buffers, typically when using a high number of QPs with large message sizes. The root cause was the inefficient use of rand(). This has been resolved by replacing it with a faster pseudo-random algorithm.</li><li>A potential deadlock that could occur during the handling of peer memory registration failures.</li><li>The following error occurred when switching to SwitchDev mode: &quot;mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)&quot;</li><li>A sysfs issue that occurred when accessing hardware counters from within a namespace.</li><li>&quot;ibstat&quot; would fail and crash when encountering a non-RoCE/IB device, preventing it from displaying information for the remaining valid RoCE/IB devices.</li><li>Bandwidth degradation in cases of high number of QPs, where polling only 16 CQEs per iteration may not be sufficient to process all completions in time.</li><li>A race condition between firmware syndrome report and driver initialization during boot.</li><li>The driver failed to load when a firmware syndrome was detected during boot.</li><li>The mlnx_tune -l command did not list several operating systems that were in fact supported.</li><li>The kernel did not define TCA_TUNNEL_KEY_ENC_SRC_PORT. To align offload behavior with non-offload, the OVS community introduced a commit ( netdev-offload-tc: Fix offload of tunnel key tp_src) that causes offload to fail if this tunnel attribute is used. Now, any rule with a tunnel set action that includes a tunnel source port can no longer be offloaded.</li><li>LLDP traffic from VFs or BF host PFs was not reaching the representor kernel interfaces.</li><li>Flows where both the inner and outer destination (dst) and/or source (src) MAC addresses were rewritten to the same value, the outer MAC address rewrite was ignored, leading to an outer MAC address of 00:00:00:00:00:00.</li><li>Enabling sFlow with OVN caused OVS to crash.</li><li>OVS crashed unexpectedly after DPUs repeatedly broadcast the error message &ldquo;packet with own source address.&rdquo;</li><li>Changing the hw-offload setting from true to false while ports were configured led to errors reported in the OVS log.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン25.04-0.6.1.1には、次の新機能と変更が含まれています。</strong></p><ul><li>トラストロックダウンヘルスシンドローム：トラストロックダウン用の新しいヘルスシンドロームを追加し、ヘルスバッファー内のCRRビットを公開します。CRRビットが設定されている場合、シンドロームの回復にはコールドリセットが必要であることを示しています。</li><li>ハードウェアクロックごとに1つのPTPデバイス：PHCは通常、複数の機能間で共有されます。現在、ドライバーは同じPHCを共有するネットワークインターフェイスごとに個別のPTPデバイスを作成するため、冗長性があり、複雑さが増しています。この問題を解決するために、リアルタイムモードで動作しているときに共有されたPHCを表す1つのPTPデバイスが作成されるようになりました。</li><li>IB状態遷移のログ：カーネルログ (dmesg) にログメッセージを追加することで、IBデバイスの状態遷移の可視性が向上しました。IBデバイスの状態が変化するたびに、対応するメッセージが記録されます。例えば、\"mlx5_0: Port: 1 Link DOWN\"などです。</li><li>オプションカウンターのバインディングサポートと新しいパケット/バイトカウンター：以前は、オプションカウンターはリンクごとにのみ使用可能でした。このリリースでは、オプションカウンターを特定のカウンターオブジェクトにバインドする機能が導入され、ユーザーは特定のQPグループ全体でオプションカウンターを追跡できるようになりました。自動バインディングモードと手動バインディングモードの両方がサポートされます。どちらの場合も、QPにバインドされるオプションカウンターは、バインド時にリンク上で現在設定されているカウンターです。さらに、RDMAのイングレストラフィックとイーグレストラフィックを追跡する4つの新しいオプションカウンター (rdma_tx_bytes、rdma_tx_packets、rdma_rx_bytes、rdma_rx_packets) が導入されました。この機能はiproute2パッケージを介してユーザーに公開されますが、この機能をサポートするにはこのパッケージをアップデートする必要があります。</li><li>User CAPability (UCAP) API：User CAPability (UCAP) APIは、特定のファームウェア権限を持つユーザーコンテキストを作成するためのメカニズムを導入します。各機能をルートレベルの読み取り/書き込みアクセスを持つキャラクター型デバイスとして公開することで、ファームウェア機能に対するきめ細かな制御を実現します。ルートプロセスでは、対応するキャラクター型デバイスへのアクセスを許可することで、ユーザーにこれらの権限を付与できます。UCAPファイル記述子を使用してユーザーコンテキストが作成されると、ユーザーコンテキストは関連付けられている権限を継承します。mlx5の場合、2つのUCAPキャラクター型デバイスが提供され、そのうちの少なくとも1つを使用して開かれたユーザーコンテキストが特権として扱われます。特権コマンドの実行を保証するために、特権ユーザーがデバイス上でアクティブな場合、非特権コマンドが制限されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン25.04-0.6.1.1で修正されました。</strong></p><ul><li>メッセージサイズの大きい多数のQPを使用する場合など、大きなバッファーの割り当て中に、バッファーの初期化がパフォーマンスのボトルネックになっていました。根本的な原因は、rand() の非効率的な使用でした。この問題は、より高速な疑似ランダムアルゴリズムに置き換えることで解決されました。</li><li>ピアメモリ登録の失敗の処理中に発生する可能性のあるデッドロック。</li><li>SwitchDevモードに切り替える際に次のエラーが発生しました。\"mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)\"</li><li>名前空間内からハードウェアカウンターにアクセスする際に発生したsysfsの問題。</li><li>\"ibstat\"は、RoCE/IB以外のデバイスを見つけると失敗してクラッシュし、残りの有効なRoCE/IBデバイスの情報を表示できなくなります。</li><li>QPの数が多い場合に帯域幅が低下し、反復ごとに16個のCQEをポーリングするだけでは、すべての完了を時間内に処理するのに十分ではない可能性があります。</li><li>ブート中のファームウェアシンドロームレポートとドライバー初期化の間の競合状態。</li><li>ブート中にファームウェアシンドロームが検出されたため、ドライバーのロードに失敗しました。</li><li>mlnx_tune -lコマンドでは、実際にサポートされているいくつかのオペレーティングシステムがリストされませんでした。</li><li>カーネルはTCA_TUNNEL_KEY_ENC_SRC_PORTを定義しませんでした。オフロードの動作を非オフロードと一致させるために、OVSコミュニティは、このトンネル属性が使用されている場合にオフロードが失敗するコミット (netdev-offload-tc：トンネルキーtp_srcのオフロードを修正) を導入しました。これで、トンネルのソースポートを含むトンネルセットアクションを持つすべてのルールはオフロードできなくなります。</li><li>VFまたはBFホストPFからのLLDPトラフィックが、リプレゼンターカーネルインターフェイスに到達していませんでした。</li><li>内部と外部の両方の宛先 (dst) および/または送信元 (src) MACアドレスが同じ値に書き換えられたフローで、外部MACアドレスの書き換えは無視され、外部MACアドレスが00:00:00:00:00:00 になります。</li><li>OVNでsFlowを有効にすると、OVSがクラッシュしました。</li><li>DPUが\"packet with own source address\"というエラーメッセージを繰り返しブロードキャストした後、OVSが予期せずクラッシュしました。</li><li>ポートの設定中にhw-offload設定をtrueからfalseに変更すると、OVSログにエラーが報告されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.04-0.6.1.1:</strong></p><ul><li>Trust Lockdown Health Syndrome: Added a new health syndrome for trust lockdown and expose the CRR bit in the health buffer. When the CRR bit is set, it indicates that the syndrome requires a cold reset for recovery.</li><li>A Single PTP Device per Hardware Clock: PHC is typically shared across multiple functions. Currently, the driver creates a separate PTP device for each network interface sharing the same PHC, resulting in redundancy and added complexity. To address this, a single PTP device is now created to represent the shared PHC when operating in real-time mode.</li><li>Log IB State Transitions: Enhanced visibility into IB device state transitions by adding log messages to the kernel log (dmesg). Each time an IB device changes state, a corresponding message will be logged. For example: &quot;mlx5_0: Port: 1 Link DOWN&quot;.</li><li>Optional-counters Binding Support and New Packets/bytes Counters: Previously, optional counters were available only on a per-link basis. This release introduces the ability to bind optional counters to a specific counter object, enabling users to track optional counters across a specific QP group. Support is provided for both automatic and manual binding modes. In both cases, the optional counters that are bound to the QP are those currently configured on the link at the time of binding. Additionally, four new optional counters that track RDMA ingress and egress traffic are introduced: rdma_tx_bytes; rdma_tx_packets; rdma_rx_bytes; rdma_rx_packets. This functionality is exposed to users via the iproute2 package, which must be updated to support this feature.</li><li>User CAPability (UCAP) API: The User CAPability (UCAP) API introduces a mechanism for creating user contexts with specific firmware privileges. It offers fine-grained control over firmware features by exposing each capability as a character device with root-level read-write access. Root processes can grant users these privileges by allowing access to the corresponding character devices. When a user context is created using a UCAP file descriptor, it inherits the associated privileges. For mlx5, two UCAP character devices are provided, and any user context opened with at least one of them is treated as privileged. To guarantee the execution of privileged commands, non-privileged commands are restricted when a privileged user is active on the device.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.04-0.6.1.1:</strong></p><ul><li>Buffer initialization became a performance bottleneck during the allocation of large buffers, typically when using a high number of QPs with large message sizes. The root cause was the inefficient use of rand(). This has been resolved by replacing it with a faster pseudo-random algorithm.</li><li>A potential deadlock that could occur during the handling of peer memory registration failures.</li><li>The following error occurred when switching to SwitchDev mode: &quot;mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)&quot;</li><li>A sysfs issue that occurred when accessing hardware counters from within a namespace.</li><li>&quot;ibstat&quot; would fail and crash when encountering a non-RoCE/IB device, preventing it from displaying information for the remaining valid RoCE/IB devices.</li><li>Bandwidth degradation in cases of high number of QPs, where polling only 16 CQEs per iteration may not be sufficient to process all completions in time.</li><li>A race condition between firmware syndrome report and driver initialization during boot.</li><li>The driver failed to load when a firmware syndrome was detected during boot.</li><li>The mlnx_tune -l command did not list several operating systems that were in fact supported.</li><li>The kernel did not define TCA_TUNNEL_KEY_ENC_SRC_PORT. To align offload behavior with non-offload, the OVS community introduced a commit ( netdev-offload-tc: Fix offload of tunnel key tp_src) that causes offload to fail if this tunnel attribute is used. Now, any rule with a tunnel set action that includes a tunnel source port can no longer be offloaded.</li><li>LLDP traffic from VFs or BF host PFs was not reaching the representor kernel interfaces.</li><li>Flows where both the inner and outer destination (dst) and/or source (src) MAC addresses were rewritten to the same value, the outer MAC address rewrite was ignored, leading to an outer MAC address of 00:00:00:00:00:00.</li><li>Enabling sFlow with OVN caused OVS to crash.</li><li>OVS crashed unexpectedly after DPUs repeatedly broadcast the error message &ldquo;packet with own source address.&rdquo;</li><li>Changing the hw-offload setting from true to false while ports were configured led to errors reported in the OVS log.</li></ul>","Lang":"cn"}],"Version":"25.04-0.6.6.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"cn"}],"Version":"25.07-0.9.7.0"}],"SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d95407aea34f4c9684e045b42ce5992b"}]},{"ProductId":"6aac2d7fdad54ca7910ee0bb1e81d6f3","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB NDR200 1p OSFP MCX75310AAS Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"28_46_3048-MCX75310AAS-HEAT_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-102115b30074","Version":"28.46.3048"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージ for HPE InfiniBand NDR200 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター。HPE部品番号P45642-B21およびP45642-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported NDR200 cables and transceivers:</strong></p><p>&nbsp;</p><p><strong>NDR200 HCA to Switch:</strong></p><ul><li>P45698-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P49766-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 3m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 5m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 10m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 15m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 20m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 30m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li></ul><p><strong>NDR200 HCA side transceiver:</strong></p><ul><li>P49764-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR/Ethernet 1x400Gb OSFP Multi-mode 50m HCA-side Transceiver&nbsp;&nbsp; &nbsp;(HCA Multi-mode optical fiber transceiver)</li></ul><p><br />Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるNDR200ケーブルおよびトランシーバー：</strong></p><p> </p><p><strong>NDR200 HCA対スイッチ：</strong></p><ul><li>P45698-B22        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B24        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B25        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B26        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B23        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P50397-B21        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4mスプリッターアクティブ銅線ケーブル    （HCA対スイッチ）</li><li>P50397-B22        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5mスプリッターアクティブ銅線ケーブル    （HCA対スイッチ）</li><li>P49766-B21        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード3mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B22        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード5mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B23        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード10mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B24        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード15mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B25        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード20mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B26        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード30mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li></ul><p><strong>NDR200 HCA側トランシーバー：</strong></p><ul><li>P49764-B21        HPE InfiniBand NDR/Ethernet 1x400Gb OSFPマルチモード50m HCA側トランシーバー（HCAマルチモード光ファイバートランシーバー）</li></ul><p><br />注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported NDR200 cables and transceivers:</strong></p><p>&nbsp;</p><p><strong>NDR200 HCA to Switch:</strong></p><ul><li>P45698-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P49766-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 3m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 5m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 10m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 15m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 20m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 30m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li></ul><p><strong>NDR200 HCA side transceiver:</strong></p><ul><li>P49764-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR/Ethernet 1x400Gb OSFP Multi-mode 50m HCA-side Transceiver&nbsp;&nbsp; &nbsp;(HCA Multi-mode optical fiber transceiver)</li></ul><p><br />Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"9509729","DateModified":"2025-10-10T11:24:15","FileList":["28_46_3048-MCX75310AAS-HEAT_HPE_Ax.pldm.signed","28_46_3048-MCX75310AAS-HEAT_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"1b8f2ebffd83d3429baa540826359521","Name":"28_46_3048-MCX75310AAS-HEAT_HPE_Ax.pldm.fwpkg","Release":"2025-10-10T11:21:41","Revision":"","SHA1Sum":"71ee93a048a9838a1ba3c4e49ab5a341c1f18aba","SHA256Sum":"084e5ab99c6ef8ae26621219db838864c331516977875e3f04f8f68d750caef5","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-102115b30074"],"TypeOfChange":"1","Version":"28.46.3048"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ(FWPKG) for HPE InfiniBand NDR200 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター。HPE部品番号P45642-B21およびP45642-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1021","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30074","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-30T09:58:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン28.45.1200には、以下の新機能と変更が含まれます。</strong></p><ul><li>SPDM応答に1ミリ秒の遅延を導入しました。</li></ul>","Fixes":"<p><strong>バージョン28.45.1200には、以下の修正が含まれています。</strong></p><ul><li>DC InfiniBand機能を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"cn"}],"Version":"28.45.1200"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;28.46.3048:</strong></p><ul><li>This release contains important reliability improvements and security&nbsp;hardening enhancements. HPE recommends upgrading your devices&nbsp;firmware to this release to improve the devices&rsquo; firmware security and&nbsp;reliability.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version&nbsp;28.46.3048:</strong></p><ul><li>The adapter card would drop NC-SI over MCTP commands&nbsp;when padding bytes were present after the NC-SI checksum.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;28.46.3048:</strong></p><ul><li>This release contains important reliability improvements and security&nbsp;hardening enhancements. HPE recommends upgrading your devices&nbsp;firmware to this release to improve the devices&rsquo; firmware security and&nbsp;reliability.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version&nbsp;28.46.3048:</strong></p><ul><li>The adapter card would drop NC-SI over MCTP commands&nbsp;when padding bytes were present after the NC-SI checksum.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;28.46.3048:</strong></p><ul><li>This release contains important reliability improvements and security&nbsp;hardening enhancements. HPE recommends upgrading your devices&nbsp;firmware to this release to improve the devices&rsquo; firmware security and&nbsp;reliability.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version&nbsp;28.46.3048:</strong></p><ul><li>The adapter card would drop NC-SI over MCTP commands&nbsp;when padding bytes were present after the NC-SI checksum.</li></ul>","Lang":"cn"}],"Version":"28.46.3048"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX75310AAS-HEAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"4aecd28ce4dd4b41827a4c3da3244ebc"}]},{"ProductId":"d8c86b5c3ce7444dbebf7bd215bf1a32","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3865.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen9 and Gen10 server series HPE Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen9 and Gen10 server series HPE Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Gen9およびGen10サーバーシリーズHPE Intel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th>Single NVM Version</th></tr></thead><tbody><tr><td>HPE Ethernet 1Gb 2-port 361i Adapter</td><td>8000119A</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 361T Adapter</td><td>80001147</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366FLR Adapter</td><td>800011A1</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366T Adapter</td><td>800011F1</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368i Adapter</td><td>80003AC5</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter</td><td>80003AC2</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 369i Adapter</td><td>80003AC3</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568i Adapter</td><td>80003AC4</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter</td><td>80003AC2</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</td><td>80003AC2</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 563i Adapter</td><td>800035C0</td><td>1.1375.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter</td><td>8000F231</td><td>1.3827.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-T Adapter</td><td>800016F1</td><td>1.3827.0</td><td>10.55.3</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562SFP+ Adapter</td><td>8000F232</td><td>1.3827.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562T Adapter</td><td>800016EF</td><td>1.3827.0</td><td>10.55.3</td></tr></tbody></table><p>The combo image v1.3827.0&nbsp;includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.59, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.86, 10GbE - v8.2.91, 40GbE - v5.0.20</p><p>Single NVM Version is new firmware format which represent an unified version in place of the previously used EEPROM/NVM Version or OROM version.</p><p>&nbsp;</p><p><strong>This software package no longer contains Firmware for the below listed supported network adapters:</strong></p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 2-port 363i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Communication Board&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560SFP+ Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561FLR-T Adapter&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561T Adapter</p><ul><li>The latest firmware version of above adapters, please refer to the link :&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\" rel=\"noopener noreferrer\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes</a></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th>Single NVM Version</th></tr></thead><tbody><tr><td>HPE Ethernet 1Gb 2-port 361i Adapter</td><td>8000119A</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 361T Adapter</td><td>80001147</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366FLR Adapter</td><td>800011A1</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366T Adapter</td><td>800011F1</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368i Adapter</td><td>80003AC5</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter</td><td>80003AC2</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 369i Adapter</td><td>80003AC3</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568i Adapter</td><td>80003AC4</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter</td><td>80003AC2</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</td><td>80003AC2</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 563i Adapter</td><td>800035C0</td><td>1.1375.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter</td><td>8000F231</td><td>1.3827.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-T Adapter</td><td>800016F1</td><td>1.3827.0</td><td>10.55.3</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562SFP+ Adapter</td><td>8000F232</td><td>1.3827.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562T Adapter</td><td>800016EF</td><td>1.3827.0</td><td>10.55.3</td></tr></tbody></table><p>The combo image v1.3827.0&nbsp;includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.59, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.86, 10GbE - v8.2.91, 40GbE - v5.0.20</p><p>Single NVM Version is new firmware format which represent an unified version in place of the previously used EEPROM/NVM Version or OROM version.</p><p>&nbsp;</p><p><strong>This software package no longer contains Firmware for the below listed supported network adapters:</strong></p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 2-port 363i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Communication Board&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560SFP+ Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561FLR-T Adapter&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561T Adapter</p><ul><li>The latest firmware version of above adapters, please refer to the link :&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\" rel=\"noopener noreferrer\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes</a></li></ul>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVMバージョン</th><th>OROMバージョン</th><th>シングルNVMバージョン</th></tr></thead><tbody><tr><td>HPE Ethernet 1Gb 2ポート361iアダプター</td><td>8000119A</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2ポート361Tアダプター</td><td>80001147</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4ポート366FLRアダプター</td><td>800011A1</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4ポート366Tアダプター</td><td>800011F1</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2ポート368iアダプター</td><td>80003AC5</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2ポート368FLR-MMTアダプター</td><td>80003AC2</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4ポート369iアダプター</td><td>80003AC3</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2ポート568iアダプター</td><td>80003AC4</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2ポート568FLR-MMSFP+アダプター</td><td>80003AC2</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2ポート568FLR-MMTアダプター</td><td>80003AC2</td><td>1.3827.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2ポート563iアダプター</td><td>800035C0</td><td>1.1375.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2ポート562FLR-SFP+アダプター</td><td>8000F231</td><td>1.3827.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2ポート562FLR-Tアダプター</td><td>800016F1</td><td>1.3827.0</td><td>10.55.3</td></tr><tr><td>HPE Ethernet 10Gb 2ポート562SFP+アダプター</td><td>8000F232</td><td>1.3827.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2ポート562Tアダプター</td><td>800016EF</td><td>1.3827.0</td><td>10.55.3</td></tr></tbody></table><p>コンボイメージ v1.3827.0 には以下が含まれます。 Boot Agent: 1GbE - v1.5.90、10GbE - v2.4.59、40GbE - v1.1.45& UEFIドライバー: 1GbE - v9.8.86、10GbE - v8.2.91、40GbE - v5.0.20</p><p>シングルNVMバージョンは、以前に使用されていたバージョンEEPROM/NVMまたはOROMバージョンの代わりに統合されたバージョンを表す新しいファームウェア形式です。</p><p> </p><p><strong>このソフトウェアパッケージには、以下にリストされるサポートされるネットワークアダプター用のファームウェアが含まれなくなりました：</strong></p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 2ポート363iアダプター         </p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4ポート366iアダプター     </p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4ポート366i通信ボード       </p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート560FLR-SFP+アダプター</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート560SFP+アダプター     </p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート561FLR-Tアダプター    </p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート561Tアダプター</p><ul><li>上記アダプターの最新のファームウェアバージョンについては、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&tab=releaseNotes\" rel=\"noopener noreferrer\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&tab=releaseNotes\">https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&tab=releaseNotes</a></li></ul>"}],"Files":[{"Bytes":"10393384","DateModified":"2025-09-15T22:09:55","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/CP068725.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/CP068725.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/BootIMG_FVL4HP.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_361T.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_361T_H65030-003_2.25_80001147.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_366FLR_G41713-00x_800011A1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_366FLR_G41713-00x_800011A1.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_366T_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_366T_Quad_H73104-00x_800011F1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_366T_Quad_H73104-00x_800011F1.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_369i_88E1512_P01_88E1512_P23_NCSI_6p00_80003AC3.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_40G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_562FLR-SFP_DP_H47655-000_11p1p7_9p50_8000F231.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_562SFP_DP_H44490-000_11p1p7_9p50_8000F232.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_563i_KR_DP_800035C0.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_568i_Backplane_2x10G_P01_NCSI_6p00_80003AC4.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_Apollo_PHY_Auto_Detect_NCSI_6p00_80003AC2.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_6p00_80003AC5.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/HPE_XG_SGVL_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.35.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068725.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068725.scexe"],"MD5Sum":"37dd5ba9ba35364b95c91789b68b9bbe","Name":"firmware-nic-intel-1.35.0-1.1.x86_64.rpm","Release":"2025-09-16T02:58:58","Revision":"","SHA1Sum":"4a68f20e1e80ad2d1d5c43832fe47e7960e9518f","SHA256Sum":"e076a842ed5d31a71a0f7c7c10b28d4b3f228a93080ff03af1359922d46a215b","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"1.35.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":3600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca93656a5","SWKey":"kmod-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec805649d9","SWKey":"kmod-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36","SWKey":"hp-ixgbe-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccba99d79","SWKey":"kmod-hp-ixgbe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li><br /><li>&nbsp;</li></ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</a></li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 4-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"},{"Lang":"cn","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li><br /><li>&nbsp;</li></ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</a></li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 4-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"},{"Lang":"ja","Value":"<p><em><strong><em><strong><em><strong><em><strong>rpmインストールによるファームウェアのアップデート：</strong></em></strong></em></strong></em></strong></em></p><ul><li>次のコマンドを使用して、NICファームウェアをインストールします：  <em>rpm -ivh <rpm_filename>.rpm.  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><br /><li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。詳細については、'firmware-nic-*'フォルダーのCPxxxxxx.txtファイルを参照してください。firmware-nic-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。</li><br /><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します：<ul><li><em>./</em>CPxxxxxx<em>.scexe</em>（'/usr/lib/x86_64-linux-gnu'内）（または）</li><li>firmware-nic-*ロケーションの<em>./setup</em></li></ul></li><br /><li>rpmをアンインストールするには、次のコマンドを実行します：<em>rpm -e <rpm_package_name></em></li></ul><p><br /><em><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></em></p><ul><li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><br /><li>usr/lib/x86_64-linux-gnu/firmware-nic-*ロケーションに移動し、<em>./hpsetup</em>を実行してファームウェアをアップデートします。'firmware-nic-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><br /><li> </li></ul><p><em><strong>追加情報：</strong></em></p><ul><li>特定のシナリオでは、EPROMをアップデートした後にシステムを再起動して、アダプターのフラッシュROM（OROM）をアップデートするためにコンポーネントの再実行を要求されることがあります。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるCPxxxxxx.logファイルに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアrpmパッケージのインストール（rpm -ivh）は、アダプターのファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。アダプターのファームウェアをアップデートするには、上記の手順に従う必要があります。 </li><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。ダウングレードに関する制限について詳しくは、カスタマーアドバイザリ<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171ja_jp</a>を参照してください</li><li>次のネットワークアダプターについては、アップデートを反映させるためにファームウェアのインストール後にAC電源を再投入する必要があります。<br />HPE Ethernet 1Gb 2ポート368iアダプター<br />HPE Ethernet 1Gb 4ポート369iアダプター<br />HPE Ethernet 1Gb 2ポート368FLR-MMTアダプター<br />HPE Ethernet 10Gb 2ポート568FLR-MMSFP+アダプター<br />HPE Ethernet 10Gb 2ポート568FLR-MMTアダプター</li></ul><p> </p><p><em><strong>ドライバー依存関係：</strong></em></p><p>この製品は、システム内に存在するすべてのIntel NICデバイスをスキャンします。システムに複数のIntel E810/X710/I350/X550ネットワークアダプターが存在する場合、一部のカーネルでは、対応するインボックスNICドライバーがこの製品のファームウェアライブラリで正常に動作しない可能性があります。この製品でエラーが発生した場合は、どのIntelデバイスのファームウェアをアップグレードしようとしているかに関係なく、システム上のすべてのIntel NICデバイスに対してIntel OOB NICドライバー (igb/ixgbe/i40e/ice) をインストールする必要があります。</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"cn","Value":"HPE Intel Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"ja","Value":"HPE Intelオンラインファームウェアアップグレードユーティリティfor Linux x86_64（HPE ProLiant Gen9およびGen10サーバーシリーズ専用）。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T03:04:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、タイムアウトにより 562SFP+/x710 アダプターでFWアップグレードが失敗する問題を修正しました。</li><li>この製品は、4ポートイーサーネットアダプターでリンクがダウンしているときに、ポート2とポート3がリンクダウンを報告しないことがある問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"cn"}],"Version":"1.34.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"1.35.0"}],"SWKeys":[{"Name":"INTEL","SWKeyExpectedPath":"firmware:intel_nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"435b77df42df4c90b70b025c94cca18d"}]},{"ProductId":"e9e7d66071a042078eec11daa5bcf114","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4320052","DateModified":"2025-08-03T01:47:47","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-1.1/CP067343.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-1.1/SKESTNDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067343.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067343.scexe"],"MD5Sum":"44350454870f7eb92cf4e697cec49281","Name":"firmware-hdd-3d97759111_0HPDB-1.1_amd64.deb","Release":"2025-08-03T06:39:10","Revision":"","SHA1Sum":"6dcf7d913ef715e98d3051d001a6ae6ddb1b513f","SHA256Sum":"58598f8a3eed8d14a1c555eae134ca0b2739e19f1b7c123506d6a3e8d839def8","Size":"4MB","TargetGUIDs":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"CP040309.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000300JWCPK","TargetGUID":"452340a5-3048-3030-3330-304a5743504b","Type":"sas"},{"Id":"EH000600JWCPL","TargetGUID":"452340a5-3048-3030-3630-304a5743504c","Type":"sas"},{"Id":"EH000900JWCPN","TargetGUID":"452340a5-3048-3030-3930-304a5743504e","Type":"sas"},{"Id":"EH000900JXLVU","TargetGUID":"452340a5-3048-3030-3930-304a584c5655","Type":"sas"},{"Id":"EH000300JXLVR","TargetGUID":"452340a5-3048-3030-3330-304a584c5652","Type":"sas"},{"Id":"EH000600JXLVT","TargetGUID":"452340a5-3048-3030-3630-304a584c5654","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:31:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a9f53cc9e0ca42a59f10422a1fc318f8"}]},{"ProductId":"9c8cb2fad4c14cc880a30a5cd84639ec","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3940364","DateModified":"2025-08-02T21:53:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-1.1/CP067378.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-1.1/WBCQssssASFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067378.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067378.scexe"],"MD5Sum":"685ce3fb09e6d3d9a12c67446ebba07a","Name":"firmware-hdd-24384980ec_0HPD2-1.1_amd64.deb","Release":"2025-08-03T02:45:40","Revision":"","SHA1Sum":"e189d4452016c2dde9395977d73ebc8805fe67b0","SHA256Sum":"a5528124d0464132afca641c9b685d1df0cd38d3d0727f7e9a669d975606a405","Size":"3MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP040307.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MO000800JXBEV","TargetGUID":"4d2340a5-304f-3030-3830-304a58424556","Type":"sas"},{"Id":"MO001600JXBFP","TargetGUID":"4d2340a5-304f-3130-3630-304a58424650","Type":"sas"},{"Id":"MO003200JXBFQ","TargetGUID":"4d2340a5-304f-3330-3230-304a58424651","Type":"sas"},{"Id":"MO006400JXBFR","TargetGUID":"4d2340a5-304f-3630-3430-304a58424652","Type":"sas"},{"Id":"MO000960JXBFA","TargetGUID":"4d2340a5-304f-3030-3936-304a58424641","Type":"sas"},{"Id":"MO001920JXBFT","TargetGUID":"4d2340a5-304f-3130-3932-304a58424654","Type":"sas"},{"Id":"MO003840JXBFU","TargetGUID":"4d2340a5-304f-3330-3834-304a58424655","Type":"sas"},{"Id":"MO007680JXBGA","TargetGUID":"4d2340a5-304f-3730-3638-304a58424741","Type":"sas"},{"Id":"MO015360JXBFV","TargetGUID":"4d2340a5-304f-3531-3336-304a58424656","Type":"sas"},{"Id":"EO000400JXBEU","TargetGUID":"452340a5-304f-3030-3430-304a58424555","Type":"sas"},{"Id":"EO000800JXBFL","TargetGUID":"452340a5-304f-3030-3830-304a5842464c","Type":"sas"},{"Id":"EO001600JXBFN","TargetGUID":"452340a5-304f-3130-3630-304a5842464e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:06:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li></ul>","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"aa48a757155d4eb09cbd5a6511149837"}]},{"ProductId":"9141b4ee76c74b70a4eb2f021bfa217f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV "},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3239056","DateModified":"2025-11-15T19:52:17","FileList":["cp068644.xml","cpqsetup.exe","KAPM5ALSHPDB.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"268a873f2885cacc1316cd5621db7271","Name":"cp068644.exe","Release":"2025-11-15T19:47:48","Revision":"D","SHA1Sum":"6a3f8647269e8a34502ee7ac5da6d48540934420","SHA256Sum":"ffb18b70bb68d5007cf1774f6b0b6f23d31a2b24903a3b6974f215150b51655f","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"},{"Lang":"ja","Value":"オンライン HDD/SSDフラッシュコンポーネントfor Windows (x64) - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO007680JWTBP","TargetGUID":"562340a5-304f-3730-3638-304a57544250","Type":"sas"},{"Id":"MO006400JWTCD","TargetGUID":"4d2340a5-304f-3630-3430-304a57544344","Type":"sas"},{"Id":"VO003840JWTBN","TargetGUID":"562340a5-304f-3330-3834-304a5754424e","Type":"sas"},{"Id":"MO003200JWTBU","TargetGUID":"4d2340a5-304f-3330-3230-304a57544255","Type":"sas"},{"Id":"EO003200JWTCC","TargetGUID":"452340a5-304f-3330-3230-304a57544343","Type":"sas"},{"Id":"VO001920JWTBL","TargetGUID":"562340a5-304f-3130-3932-304a5754424c","Type":"sas"},{"Id":"MO001600JWTBT","TargetGUID":"4d2340a5-304f-3130-3630-304a57544254","Type":"sas"},{"Id":"EO001600JWTCB","TargetGUID":"452340a5-304f-3130-3630-304a57544342","Type":"sas"},{"Id":"VO000960JWTBK","TargetGUID":"562340a5-304f-3030-3936-304a5754424b","Type":"sas"},{"Id":"MO000800JWTBR","TargetGUID":"4d2340a5-304f-3030-3830-304a57544252","Type":"sas"},{"Id":"EO000800JWTCA","TargetGUID":"452340a5-304f-3030-3830-304a57544341","Type":"sas"},{"Id":"MO000400JWTBQ","TargetGUID":"4d2340a5-304f-3030-3430-304a57544251","Type":"sas"},{"Id":"EO000400JWTBV","TargetGUID":"452340a5-304f-3030-3430-304a57544256","Type":"sas"},{"Id":"MO001920JWWWV","TargetGUID":"4d2340a5-304f-3130-3932-304a57575756","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:13:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2ba38c58637a46b988c479eb0055307b"}]},{"ProductId":"d05a1433339f497faa2734fb31c015eb","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB016000GWXKK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3973376","DateModified":"2025-11-15T08:54:15","FileList":["cp068759.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG08acHPG4.REL"],"MD5Sum":"0763a35cb343c494bd7285753080b43b","Name":"cp068759.exe","Release":"2025-11-15T08:48:53","Revision":"D","SHA1Sum":"7b15d5f9dc9614289ef9d475faaf0c3e23ecf62c","SHA256Sum":"cdffb69ec805d8d89473a18d60bf702e75f7199fd6b022ae60b4a4d0d535ee63","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB016000GWXKK Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB016000GWXKKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB016000GWXKK","TargetGUID":"4d2340a5-3042-3631-3030-304757584b4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T09:18:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0bf8a3966c3a47fb902a7994b439e771"}]},{"ProductId":"779f4f17fec64b6b9acf9ede668fc68a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"5117645","DateModified":"2025-09-17T11:59:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/CP068865.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/TA15SEN0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068865.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068865.scexe"],"MD5Sum":"3f9de3c3f62aea6e18710e2609a0462c","Name":"firmware-hdd-24fe569b72-HPD6-2.1.x86_64.rpm","Release":"2025-09-17T16:48:05","Revision":"B","SHA1Sum":"c9b67f99ef66a6d0194dbefc1a648dc4d989d938","SHA256Sum":"482737fb747160512f4141175bfaabb9a9b5983492ce8580bc8251b8ab38dec8","Size":"4MB","TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"CP041564.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP.<nnnnnn>scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG001200JWJNK","TargetGUID":"452340a5-3047-3130-3230-304a574a4e4b","Type":"sas"},{"Id":"EG000600JWJNH","TargetGUID":"452340a5-3047-3030-3630-304a574a4e48","Type":"sas"},{"Id":"EG000300JWSJP","TargetGUID":"452340a5-3047-3030-3330-304a57534a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T20:17:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8743e3c43b1a4290be022781533c69f9"}]},{"ProductId":"a96fcafbb6d4411b8c5383684726a0e9","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U61_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.52 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16814705","DateModified":"2026-01-13T08:06:49","FileList":["payload.json","U61_2.52_01_09_2026.signed.flash","U61_2.52_01_09_2026.xml"],"MD5Sum":"700a6c64835bd68a87f6edc2b02c558f","Name":"U61_2.52_01_09_2026.fwpkg","Release":"2026-01-13T08:04:19","Revision":"","SHA1Sum":"77614297ee70c2901e6549521c6467e33205b003","SHA256Sum":"d545111d33685f0270a485a159ee5789e63519248021de94d9a416638a93a60d","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.52_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant ML30 Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T06:08:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.708（2.50_07_25_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_01-09-2026"}],"SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"0e26d2b72d7043b084164e94cd7643f3"}]},{"ProductId":"be910528f863487899cf62f353be4a46","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB006000JYDNF, MB008000JYDPC and MB010000JYDNH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"}],"Files":[{"Bytes":"20905434","DateModified":"2025-06-23T12:59:32","FileList":["/CP067623_BUILD_1.data","/CP067623.vmexe64","/CP067623.vmfile","/CP067623_VMw.zip","/CP067623.xml","/payload.json","/CP067623_VMw.zip/index.xml","/CP067623_VMw.zip/vendor-index.xml","/CP067623_VMw.zip/metadata.zip","/CP067623_VMw.zip/vib20/CP067623/HPE_bootbank_CP067623_HPD5.1-8.0.0.20613240.vib","/CP067623_VMw.zip/metadata.zip/vendor-index.xml","/CP067623_VMw.zip/metadata.zip/vmware.xml","/CP067623_VMw.zip/metadata.zip/vibs/CP067623--6735350527738373804.xml","/CP067623_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067623_HPD5.1-8.0.0.20613240.xml"],"MD5Sum":"996e6d2eea5ded21ee3785f949146b6e","Name":"CP067623.zip","Release":"2025-06-23T12:58:43","Revision":"B","SHA1Sum":"f4e1d02b2092fca38a5a324fa49cc8a7c0675a13","SHA256Sum":"5ac1239d6147bfa855cd66a7b31000947f5c36bed436ba4193679358c1f1d5a7","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP067623","Version":"HPD5.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB006000JYDNF","TargetGUID":"4d2340a5-3042-3630-3030-304a59444e46","Type":"sas"},{"Id":"MB008000JYDPC","TargetGUID":"4d2340a5-3042-3830-3030-304a59445043","Type":"sas"},{"Id":"MB010000JYDNH","TargetGUID":"4d2340a5-3042-3031-3030-304a59444e48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-19T15:59:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"eeb16633cbf44ee9bee1fee95905ee44"}]},{"ProductId":"f56420e1793d48958fc061b802e973db","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB NDR200/EN 200G 1p OSFP Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"28_46_3048-MCX75310AAS-HEAT_HPE2_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-102115b30085","Version":"28.46.3048"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージ for HPE InfiniBand NDR200/Ethernet 200Gb 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター。HPE部品番号P45642-B22およびP45642-H22"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported NDR200 / 200 GbE cables and transceivers:</strong></p><p>&nbsp;</p><p><strong>HCA to Switch:</strong></p><ul><li>P45698-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P49766-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 3m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 5m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 10m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 15m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 20m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 30m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li></ul><p><strong>HCA side transceiver:</strong></p><ul><li>P49764-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR/Ethernet 1x400Gb OSFP Multi-mode 50m HCA-side Transceiver&nbsp;&nbsp; &nbsp;(HCA Multi-mode optical fiber transceiver)</li></ul><p><br />Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるNDR200 / 200 GbEケーブルおよびトランシーバー：</strong></p><p> </p><p><strong>HCA対スイッチ：</strong></p><ul><li>P45698-B22        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B24        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B25        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B26        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B23        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P50397-B21        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4mスプリッターアクティブ銅線ケーブル    （HCA対スイッチ）</li><li>P50397-B22        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5mスプリッターアクティブ銅線ケーブル    （HCA対スイッチ）</li><li>P49766-B21        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード3mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B22        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード5mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B23        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード10mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B24        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード15mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B25        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード20mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B26        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード30mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li></ul><p><strong>HCA側トランシーバー：</strong></p><ul><li>P49764-B21        HPE InfiniBand NDR/Ethernet 1x400Gb OSFPマルチモード50m HCA側トランシーバー（HCAマルチモード光ファイバートランシーバー）</li></ul><p><br />注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported NDR200 / 200 GbE cables and transceivers:</strong></p><p>&nbsp;</p><p><strong>HCA to Switch:</strong></p><ul><li>P45698-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P49766-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 3m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 5m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 10m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 15m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 20m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 30m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li></ul><p><strong>HCA side transceiver:</strong></p><ul><li>P49764-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR/Ethernet 1x400Gb OSFP Multi-mode 50m HCA-side Transceiver&nbsp;&nbsp; &nbsp;(HCA Multi-mode optical fiber transceiver)</li></ul><p><br />Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"9493835","DateModified":"2025-10-10T11:27:21","FileList":["28_46_3048-MCX75310AAS-HEAT_HPE2_Ax.pldm.signed","28_46_3048-MCX75310AAS-HEAT_HPE2_Ax.pldm.xml","payload.json"],"MD5Sum":"6fd340211560472ab9e4af926e1b0148","Name":"28_46_3048-MCX75310AAS-HEAT_HPE2_Ax.pldm.fwpkg","Release":"2025-10-10T11:24:54","Revision":"","SHA1Sum":"ed8e61097eff6292a9b82e6fa995e2757982ebc2","SHA256Sum":"32ce735a81dd53bca746e8e7e6dfa8f960252bac2fdf7cd749312f81748203f9","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-102115b30085"],"TypeOfChange":"1","Version":"28.46.3048"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ(FWPKG) for HPE InfiniBand NDR200/Ethernet 200Gb 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター。HPE部品番号P45642-B22およびP45642-H22"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1021","SubDev":"0085","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30085","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-30T10:54:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン28.45.1200には、以下の新機能と変更が含まれます。</strong></p><ul><li>SPDM応答に1ミリ秒の遅延を導入しました。</li></ul>","Fixes":"<p><strong>バージョン28.45.1200には、以下の修正が含まれています。</strong></p><ul><li>DC InfiniBand機能を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"cn"}],"Version":"28.45.1200"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;28.46.3048:</strong></p><ul><li>This release contains important reliability improvements and security&nbsp;hardening enhancements. HPE recommends upgrading your devices&nbsp;firmware to this release to improve the devices&rsquo; firmware security and&nbsp;reliability.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version&nbsp;28.46.3048:</strong></p><ul><li>The adapter card would drop NC-SI over MCTP commands&nbsp;when padding bytes were present after the NC-SI checksum.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;28.46.3048:</strong></p><ul><li>This release contains important reliability improvements and security&nbsp;hardening enhancements. HPE recommends upgrading your devices&nbsp;firmware to this release to improve the devices&rsquo; firmware security and&nbsp;reliability.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version&nbsp;28.46.3048:</strong></p><ul><li>The adapter card would drop NC-SI over MCTP commands&nbsp;when padding bytes were present after the NC-SI checksum.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;28.46.3048:</strong></p><ul><li>This release contains important reliability improvements and security&nbsp;hardening enhancements. HPE recommends upgrading your devices&nbsp;firmware to this release to improve the devices&rsquo; firmware security and&nbsp;reliability.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version&nbsp;28.46.3048:</strong></p><ul><li>The adapter card would drop NC-SI over MCTP commands&nbsp;when padding bytes were present after the NC-SI checksum.</li></ul>","Lang":"cn"}],"Version":"28.46.3048"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX75310AAS-HEAT_VPI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"17783bd8d16a49f781a100aa2b247a61"}]},{"ProductId":"bf6c1988a6474823969dd84808070288","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U40_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11826400","DateModified":"2026-01-14T01:46:15","FileList":["cp070354.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U40_3.62_01_09_2026.signed.flash"],"MD5Sum":"5f1725ef80e137dba25cc2304c10fb0c","Name":"cp070354.exe","Release":"2026-01-14T01:43:48","Revision":"","SHA1Sum":"8078802798577759318be3ea5118acaeb7b1ecfd","SHA256Sum":"5a15a9d1109fa9d882acc33c651a17e36df591e53af4c13ba6479936f6a2c182","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe&nbsp;to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;</p><p>2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファイルをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 </p><p>2.    計算された値を、HPEサポートセンターのダウンロードページにあるインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの完全性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe&nbsp;to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;</p><p>2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:33:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"1cf368babea4460ea28bf99e128195c7"}]},{"ProductId":"29456540dcc74eaf9f223e63cf50eff7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4519821","DateModified":"2025-09-21T19:53:22","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/CP068905.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068905.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068905.scexe"],"MD5Sum":"359679ad76a243fffb5d062e7e468251","Name":"firmware-hdd-aef2a690c9-HPG5-13.1.x86_64.rpm","Release":"2025-09-22T00:41:24","Revision":"M","SHA1Sum":"23a48311e02dd55e4e81e78baeda38cef4aacbc7","SHA256Sum":"06c0a19d1abcc106cc8ef5a8301f16a0c89a70b569db53d309e1d158293c449d","Size":"4MB","TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"CP040776.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPP、およびMK001920GWJPQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MK001920GWJPQ","TargetGUID":"4d2340a5-304b-3130-3932-3047574a5051","Type":"sata"},{"Id":"VK001920GWJPH","TargetGUID":"562340a5-304b-3130-3932-3047574a5048","Type":"sata"},{"Id":"MK000240GWKVK","TargetGUID":"4d2340a5-304b-3030-3234-3047574b564b","Type":"sata"},{"Id":"VK000240GWJPD","TargetGUID":"562340a5-304b-3030-3234-3047574a5044","Type":"sata"},{"Id":"VK003840GWJPK","TargetGUID":"562340a5-304b-3330-3834-3047574a504b","Type":"sata"},{"Id":"MK000480GWJPN","TargetGUID":"4d2340a5-304b-3030-3438-3047574a504e","Type":"sata"},{"Id":"VK000480GWJPE","TargetGUID":"562340a5-304b-3030-3438-3047574a5045","Type":"sata"},{"Id":"MK000960GWJPP","TargetGUID":"4d2340a5-304b-3030-3936-3047574a5050","Type":"sata"},{"Id":"VK000960GWJPF","TargetGUID":"562340a5-304b-3030-3936-3047574a5046","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:41:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul>","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"89e45fac4c3a461283ecd1b976bd4f35"}]},{"ProductId":"fdd1b58860474c42b7f3b1b7524af387","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us</a></li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us</a></li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"7375319","DateModified":"2025-09-21T20:13:21","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/CP068909.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/KPE80X0AHPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068909.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068909.scexe"],"MD5Sum":"548646462279f882228deacf81df63fe","Name":"firmware-hdd-035a863453-HPK5-11.1.x86_64.rpm","Release":"2025-09-22T00:59:42","Revision":"K","SHA1Sum":"84b6e1ab9ec2aa2f3679803d3a98b07af2adcf8f","SHA256Sum":"ff427c4e5df56b545d8ab5f392faf825b40c3009f4eb72e7f4ae79200700498e","Size":"7MB","TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"Installation":{"Command":"CP042953.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO000960KXAVL","TargetGUID":"562340a5-304f-3030-3936-304b5841564c","Type":"nvme"},{"Id":"MO000800KXAVN","TargetGUID":"4d2340a5-304f-3030-3830-304b5841564e","Type":"nvme"},{"Id":"MO001600KXAVT","TargetGUID":"4d2340a5-304f-3130-3630-304b58415654","Type":"nvme"},{"Id":"MO003200KXAVU","TargetGUID":"4d2340a5-304f-3330-3230-304b58415655","Type":"nvme"},{"Id":"MO006400KXAVV","TargetGUID":"4d2340a5-304f-3630-3430-304b58415656","Type":"nvme"},{"Id":"VO003840KXAVQ","TargetGUID":"562340a5-304f-3330-3834-304b58415651","Type":"nvme"},{"Id":"VO007680KXAVR","TargetGUID":"562340a5-304f-3730-3638-304b58415652","Type":"nvme"},{"Id":"VO001920KXAVP","TargetGUID":"562340a5-304f-3130-3932-304b58415650","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:48:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPK5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us</a></li></ul>","Lang":"cn"}],"Version":"HPK5"}],"SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d4c8d4a771074416b3a178335cb8f110"}]},{"ProductId":"c02bbf9a9f6640aeab2edb3ce124d6c6","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE e910 QSFP+ 4x10G Network Riser","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Backplane_4x10G_NCSI_4p30_80001A42.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37ce80860000","Version":"1.2684"},{"DeviceName":"HPE e910 1G RJ45 Network Rsr","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37d180860000","Version":"1.2684"},{"DeviceName":"HPE e910 2p 10GbE SFP+ Mod","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37d380860000","Version":"1.2684"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This smart component provides NIC firmware that can be installed directly on the HPE Edgeline e910/e910t System running a supported Linux Operating System installed in HPE Edgeline EL8000/EL8000t chassis."},{"Lang":"ja","Value":"This smart component provides NIC firmware that can be installed directly on the HPE Edgeline e910/e910t System running a supported Linux Operating System installed in HPE Edgeline EL8000/EL8000t chassis."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"10998266","DateModified":"2026-01-20T03:14:30","FileList":["./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/CP059432.xml","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/Immediate_offset_1.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/Immediate_offset_2.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/LBG_B2_Backplane_4x10G_NCSI_4p30_80001FC8.bin","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001FE8.bin","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/OCP_Configuration.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/QSFP.cfg","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/RJ45.cfg","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/SFP.cfg","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/file_license.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/iSCSI.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/ilorest_chif.so","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/iv.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/nvmupdate64e","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/payload_version.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/setup","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-2.1/version.txt","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP059432.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP059432.scexe"],"MD5Sum":"3682108b006ebb9425b1e835c1a65096","Name":"firmware-e910-intel-nic-fw-pack-4.30-2.1.x86_64.rpm","Release":"2026-01-20T08:58:43","Revision":"B","SHA1Sum":"0c0ea4ed80698592a64e6bebedf8b28bcc97e498","SHA256Sum":"b9d99a6d692c36cd9ecdb08d3037a03e151075712e8c0549fc86b8fe60a88394","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-37ce80860000","a6b1a447-382a-5a4f-8086-37d180860000","a6b1a447-382a-5a4f-8086-37d380860000"],"TypeOfChange":"1","Version":"4.30"}],"Installation":{"Command":"setup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To install firmware from Linux operating system on target server:</strong></p><p>&nbsp;</p><p>Execute the below commands:</p><p>&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change(cd) to the directory&nbsp;you see in the previous step and run hpsetup by typing &lsquo;./setup&rsquo; at the command prompt.</p><p><strong>Note:&nbsp;</strong>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed using SUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"},{"Lang":"ja","Value":"<p><strong>To install firmware from Linux operating system on target server:</strong></p><p>&nbsp;</p><p>Execute the below commands:</p><p>&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change(cd) to the directory&nbsp;you see in the previous step and run hpsetup by typing &lsquo;./setup&rsquo; at the command prompt.</p><p><strong>Note:&nbsp;</strong>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed using SUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Edgeline X722 NIC Firmware Component for Linux"},{"Lang":"ja","Value":"HPE Edgeline X722 NIC Firmware Component for Linux"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"10000"},"SupportedDevices":[{"Dev":"37D3","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37D380860000","Type":"pci","Ven":"8086"},{"Dev":"37CE","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37CE80860000","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37D180860000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-01-11T07:47:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"4.30"},{"ReleaseNotes":[{"Enhancements":"<p>Added RHEL OS Support</p>","Fixes":"<p>Added RHEL 9 OS Support</p>","Lang":"en"},{"Enhancements":"<p>Added RHEL OS Support</p>","Fixes":"<p>Added RHEL 9 OS Support</p>","Lang":"ja"},{"Enhancements":"<p>Added RHEL OS Support</p>","Fixes":"<p>Added RHEL 9 OS Support</p>","Lang":"cn"}],"Version":"4.30"}],"SWKeys":[{"Name":"x722","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fd310372a5564e71840f3748ee5da105"}]},{"ProductId":"5c045315a07d45779f552f6cb831a2b4","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8002"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1908"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Linux Operating Systems."},{"Lang":"cn","Value":"此软件包含有用于升级在Linux操作系统下运行的仅使用太网适配器的HPE Mellanox的固件所需的实用程序和二进制程序。"},{"Lang":"ja","Value":"このパッケージは、Linuxオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"}],"Files":[{"Bytes":"8441980","DateModified":"2025-10-10T07:08:55","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/CP069154.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1908-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1908-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/nic_fw/fw-ConnectX5-rel-16_35_8002-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.24-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069154.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069154.scexe"],"MD5Sum":"f7ae031aa49d61a732f12fe5f599c4e2","Name":"firmware-nic-mellanox-ethernet-only-1.0.24-1.1.x86_64.rpm","Release":"2025-10-10T12:06:29","Revision":"","SHA1Sum":"1aaec886ad91b62fb0588abf2766878906964e6d","SHA256Sum":"c37f1dcda40e2a564a32c036413ff6f3688a13fd419eeed7b123fd81d4eb30e0","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p><ul><li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li><li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li><li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li><li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li><li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li><li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox Ethernet only adapters"},{"Lang":"cn","Value":"用于仅使用太网适配器的HPE Mellanox的在线固件升级实用程序（Linux x86_64）"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64) for HPE Mellanox Ethernetアダプター専用"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T10:49:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2ポート640FLR-SFP28アダプター)</li><li>817753-B21 (HPE Ethernet 25Gb 2ポート640SFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>874253-B21（HPE Ethernet 100Gb 1ポート842QSFP28アダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4506で修正されました：</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.23"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.24"}],"SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"3d95aa829f2f49a4ba59bee0a711d446"}]},{"ProductId":"716670787e144aa5b4cf080bc78d2ef7","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.52 (01/09/2026)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.52 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17091722","DateModified":"2026-01-13T02:16:05","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.52_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.52_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.52_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.52_2026_01_09-1.1/CP070175.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.52_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.52_2026_01_09-1.1/U64_2.52_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.52_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.52_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.52_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070175.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070175.scexe"],"MD5Sum":"21cb3ac4d1a13ff2f59340973d1fda90","Name":"firmware-system-u64-2.52_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T08:06:53","Revision":"","SHA1Sum":"802926ff2cb4f6c50d2829d60a55bee5d0702bfd","SHA256Sum":"4fcdfb6753d919f8f9fd9a95c7bebce7a1488eeee24cd07ad79fb88d9edf8daf","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.52_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant MicroServer Gen10 Plus v2 (U64)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T06:50:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.708（2.50_07_25_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_01-09-2026"}],"SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8d47c2e051af4a49a4a9dc67d04a9b60"}]},{"ProductId":"cd4b5a9c9ed9405abbc5be7a9f037870","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5, 6 and 7 (iLO 5,6 and 7) Embedded Health and Alerting."},{"Lang":"ja","Value":"Agentless Management Service（AMSD）は、Integrated Lights Out 5、6および7（iLO 5、6および7）内蔵ヘルスおよびアラートのサポートを提供します。"},{"Lang":"cn","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5, 6 and 7 (iLO 5,6 and 7) Embedded Health and Alerting."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9737069","DateModified":"2026-01-09T02:52:33","FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/16","./usr/lib/.build-id/16/4e692ba64beb7f1a6eada0f7f26b957aad8dab","./usr/lib/.build-id/16/4e692ba64beb7f1a6eada0f7f26b957aad8dab.1","./usr/lib/.build-id/35","./usr/lib/.build-id/35/2e2bbef611618a93252b96cf97305af08eb0e9","./usr/lib/.build-id/35/2e2bbef611618a93252b96cf97305af08eb0e9.1","./usr/lib/.build-id/87","./usr/lib/.build-id/87/8ef0318718b164ee6fd457f9644e3fd0459c03","./usr/lib/.build-id/87/8ef0318718b164ee6fd457f9644e3fd0459c03.1","./usr/lib/.build-id/91","./usr/lib/.build-id/91/7e7b81f2f5428ac1ad18819ebe2710cc4fded1","./usr/lib/.build-id/b8","./usr/lib/.build-id/b8/8616ea46d030b8d2e7843dd5c4e13537700670","./usr/lib/.build-id/c7","./usr/lib/.build-id/c7/c57a4877d66de43aabc1f465488462458d7839","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/c616da505634140b76f14b0bf5b13880505c9e","./usr/lib/.build-id/c9/c616da505634140b76f14b0bf5b13880505c9e.1","./usr/lib/.build-id/ec","./usr/lib/.build-id/ec/d11f3dbef847ed1c37b94fee13aef1501ea95a","./usr/lib/.build-id/ec/d11f3dbef847ed1c37b94fee13aef1501ea95a.1","./usr/lib/.build-id/f2","./usr/lib/.build-id/f2/5e9862bee2e93c29b0521051e419bee99ab245","./usr/lib/.build-id/f2/5e9862bee2e93c29b0521051e419bee99ab245.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"MD5Sum":"e98b083207db5fa58bbe8b7b89c8acd4","Name":"amsd-4.5.0-2107.2.sles15.x86_64.rpm","Release":"2026-01-09T08:43:30","Revision":"","SHA1Sum":"c4eefae3f321dfaf1680166c90587082ff96d5aa","SHA256Sum":"1afa6e192ea0f4551ed5acf8d86144ed9a2b2b8d30ff6f0bc0ee8416d66f95fb","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.5.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service (iLO5, iLO6, iLO7) for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"Agentless Management Service (iLO5、iLO6、iLO7) for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"Agentless Management Service (iLO5, iLO6, iLO7) for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330615903307","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330715903307","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-08T08:54:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"4.4.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"4.5.0"}],"SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U74","Model":"HPE ProLiant Compute XD230 (U74)"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e555c747268a4d7799f6ca1b18532b09"}]},{"ProductId":"e8f02987fae14861a37eb27a43adf117","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"52839176","DateModified":"2025-12-03T20:25:21","FileList":["cp069948.xml","cpqsetup.exe","cp_data.xml","HPE_Windows_readme.txt","install.xml","ISSetupPrerequisites/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/vcredist_x64.exe","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/vc_redist.x64.exe","multisetup.dll","setup.exe"],"MD5Sum":"5f511e8330254f77de91db6cba8f347d","Name":"cp069948.exe","Release":"2025-12-03T20:21:34","Revision":"C","SHA1Sum":"50488873fcb750d85c2675c5026ff8c9aee50a36","SHA256Sum":"acfa85713c75ca3c94ce7d6c0816154abbe74d1cde214cb47d4c0879a6512cd8","Size":"50MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf81a7df0"],"TypeOfChange":"1","Version":"8.12.52.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>If there is an older version of HPE MRSA installed on the system, please uninstall it by going to &quot;Control Panel -&gt; Uninstall a program&quot; and then uninstall &quot;LSA&quot;.</p><p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p><p>&nbsp;</p><p><strong>NOTE: </strong>If user tries to install the same version of the build again when the build is already installed, the behavior can be erratic. Recommendation would be to un-install and install the build to make any changes to the existing installer.</p>"},{"Lang":"ja","Value":"<p>HPE MRSAの古いバージョンがシステムにインストールされている場合、\"コントロールパネル ->プログラムのアンインストール\"からアンインストールを行った後に、\"LSA\"をアンインストールしてください。</p><p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>インストールボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p><p> </p><p><strong>注記：</strong>ビルドがすでにインストールされているときに、ユーザーが同じバージョンのビルドを再度インストールしようとすると、動作が不安定になる可能性があります。既存のインストーラーに変更を加えるには、ビルドをアンインストールしてから再インストールすることをお勧めします。</p>"},{"Lang":"cn","Value":"<p>If there is an older version of HPE MRSA installed on the system, please uninstall it by going to &quot;Control Panel -&gt; Uninstall a program&quot; and then uninstall &quot;LSA&quot;.</p><p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p><p>&nbsp;</p><p><strong>NOTE: </strong>If user tries to install the same version of the build again when the build is already installed, the behavior can be erratic. Recommendation would be to un-install and install the build to make any changes to the existing installer.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for Gen10 Plus and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator for Windows 64ビット（HPE MRSA for Gen10 PlusおよびGen11コントローラー）"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for Gen10 Plus and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-01T03:13:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Change the backplane bay count information to the actual bay that is connected to controller.</li><li>Add support for users to clear NVRAM using Factory Repurpose operation</li><li>Re-order LSA GUI buttons<ul><li>Move the Rebuild button to the top before Make Online button</li><li>Add the Rebuild button in the Offline Drive warning session</li></ul></li><li>Change the recommended action for Degarded Volume to &ldquo;Make sure all the&nbsp;participating drives are connected and rebuild is complete&rdquo;.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。</li><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加</li><li>LSA GUIボタンの順序を変更<ul><li>[Rebuild]ボタンを[Make Online]ボタンの前に移動</li><li>オフラインドライブの警告セッションに[Rebuild]ボタンを追加</li></ul></li><li>劣化したボリュームの推奨アクションを[Make sure all the participating drives are connected and rebuild is complete]に変更。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Change the backplane bay count information to the actual bay that is connected to controller.</li><li>Add support for users to clear NVRAM using Factory Repurpose operation</li><li>Re-order LSA GUI buttons<ul><li>Move the Rebuild button to the top before Make Online button</li><li>Add the Rebuild button in the Offline Drive warning session</li></ul></li><li>Change the recommended action for Degarded Volume to &ldquo;Make sure all the&nbsp;participating drives are connected and rebuild is complete&rdquo;.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"8.12.52.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated component metadata.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated component metadata.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated component metadata.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"8.12.52.0"}],"SWKeys":[{"Name":"lsa.exe","SWKeyExpectedPath":"%programfiles%\\HPEMRSA\\LSIStorageAuthority\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"56e5ef487c144df4910e6fecc8a7f3e2"}]},{"ProductId":"ccbfcdbdc47644e7ab18a371d4af9d7a","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U38_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11866184","DateModified":"2026-01-14T05:36:43","FileList":["cp070247.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U38_3.62_01_09_2026.signed.flash"],"MD5Sum":"3fbec4273260f1f514c9369d06d9a06b","Name":"cp070247.exe","Release":"2026-01-14T05:34:59","Revision":"","SHA1Sum":"578aa7f309d153488501899bd8516fb19498d369","SHA256Sum":"b90fd74903c4d22501e280c8a89a999948625304fdf52ec53eea5ccea562a87b","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:37:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"940f79d811274c30986b84856604888d"}]},{"ProductId":"21c71338fdf2430b8b41f3737620822c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor and chipset."},{"Lang":"ja","Value":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"616048","DateModified":"2025-11-17T06:16:13","FileList":["cp069693.xml","cpqsetup.exe","installer.dll","pnp/","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"MD5Sum":"8642d24a5985345874e0fa20d56ca027","Name":"cp069693.exe","Release":"2025-11-17T06:14:04","Revision":"G","SHA1Sum":"ac9b336ef1d2e83bdbd2dff47d0ef4af4492b44e","SHA256Sum":"97e8b0432aff7fcc870fe52ef1121af2af157a80c4e5abc0693eaca39fca2733","Size":"601KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19006.8299"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":3600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for Intel Xeon Scalable Processors (First and Second Generation) for Microsoft Windows"},{"Lang":"ja","Value":"Microsoft Windows用インテルXeonスケーラブルプロセッサー（第1および第2世代）識別子"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-17T05:54:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19006.8299"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19006.8299"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6eae68baade34fceb2f671e066ac6a3b"}]},{"ProductId":"39040fa72ee34e15b8d90d8ca174f1ed","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The lsi-mr3 controller driver component for VMware vSphere 9.0, for use with HPE Smart Update Manager."},{"Lang":"ja","Value":"HPE Smart Update Managerで使用するVMware vSphere 9.0用lsi-mr3コントローラードライバーコンポーネント"},{"Lang":"cn","Value":"The lsi-mr3 controller driver component for VMware vSphere 9.0, for use with HPE Smart Update Manager."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"238693","DateModified":"2025-07-29T10:17:49","FileList":["/BCM_bootbank_lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240.vib","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip","/cp067967.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/index.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240.vib","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip/vmware.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip/vibs/lsi-mr3-2686125346731254711.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240.xml"],"MD5Sum":"37a5a2330c6375895780da7a9c00f335","Name":"cp067967.zip","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"f401ca3c824ec062e42128c749976dc320e7c612","SHA256Sum":"8c4971b787e6554716640242786e78a78db70df2da051b2aa833e0f76c640cdf","Size":"233KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd","20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"TypeOfChange":"1","Version":"2025.09.01","VibList":[{"Name":"lsi-mr3","Version":"7.732.04.00-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hpe/swpackages and ./hpesum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p><p><strong>リモートオンライン：</strong></p><ul><li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li><li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hpe/swpackagesディレクトリにコピーします。</li><li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li><li> CD /hpe/swpackagesおよび./hpesum</li><li> 次へボタンを選択します。</li><li> シングルターゲットの追加をクリックします。</li><li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li><li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li> Smart Update Managerの指示に従ってアップデートを行います。</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ul><li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li><li> VUMおよびesxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</li></ul>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hpe/swpackages and ./hpesum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 9.0"},{"Lang":"ja","Value":"HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plusコントローラーおよびMR416i-p、MR416i-o、MR216i-o、MR408i-o、MR216i-p、MR408i-p Gen11コントローラードライバー(64ビット) for vSphere 9.0"},{"Lang":"cn","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T04:05:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11 and Gen10 Plus Storage Controllers - Purple&nbsp;Screen of Death (PSOD) May Be Observed When Updating Controller Firmware Via&nbsp;Service Pack for ProLiant (SPP) in Remote Deployment Mode With a VMware ESXi OS</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11およびGen10 Plusストレージコントローラー - VMware ESXi OSを使用してリモート展開モードでService Pack for ProLiant (SPP) によりコントローラーのファームウェアをアップデートすると、パープルスクリーン (PSOD) が発生する場合があります</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11 and Gen10 Plus Storage Controllers - Purple&nbsp;Screen of Death (PSOD) May Be Observed When Updating Controller Firmware Via&nbsp;Service Pack for ProLiant (SPP) in Remote Deployment Mode With a VMware ESXi OS</li></ul>","Lang":"cn"}],"Version":"2025.09.01"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11 and Gen10 Plus Storage Controllers - Purple&nbsp;Screen of Death (PSOD) May Be Observed When Updating Controller Firmware Via&nbsp;Service Pack for ProLiant (SPP) in Remote Deployment Mode With a VMware ESXi OS</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11およびGen10 Plusストレージコントローラー - VMware ESXi OSを使用してリモート展開モードでService Pack for ProLiant (SPP) によりコントローラーのファームウェアをアップデートすると、パープルスクリーン (PSOD) が発生する場合があります</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11 and Gen10 Plus Storage Controllers - Purple&nbsp;Screen of Death (PSOD) May Be Observed When Updating Controller Firmware Via&nbsp;Service Pack for ProLiant (SPP) in Remote Deployment Mode With a VMware ESXi OS</li></ul>","Lang":"cn"}],"Version":"2025.09.01"}],"SWKeys":[{"Name":"Broadcom-lsi-mr3:7.732.04.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"lsi-mr3:7.732.04.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e2e71b0d29dc4fc9882f74b75f786875"}]},{"ProductId":"7a882d320d3b437c96a87679f2b6ee8f","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.09"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.09"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.09"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.09"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターのファームウェアをアップグレートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9815002","DateModified":"2025-12-02T11:54:14","FileList":["/CP068325_BUILD_10.data","/CP068325.vmexe","/CP068325.vmexe64","/CP068325.vmfile","/CP068325_VMw.zip","/CP068325.xml","/payload.json","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/doc/","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.zip","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/doc/README.txt","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.zip/index.xml","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.zip/vendor-index.xml","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.zip/metadata.zip","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.zip/vib20/CP068325/HPE_bootbank_CP068325_CP068325.10-1OEM.900.0.24580437.vib","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.zip/metadata.zip/vendor-index.xml","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.zip/metadata.zip/vmware.xml","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.zip/metadata.zip/vibs/CP068325-4177318835836569498.xml","/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437-package.zip/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.zip/metadata.zip/bulletins/Smart-Component-CP068325_CP068325.10-1OEM.900.0.24580437.xml"],"MD5Sum":"3b7270d53489703c9f114c702f051000","Name":"CP068325.zip","Release":"2025-12-02T11:50:15","Revision":"","SHA1Sum":"7305b6c42a6cf37ad7050bc431a85478f67488e7","SHA256Sum":"1c6341d85f01d7c7e01e96292f02f66e52d7b7dac9a92d473294d11dc11527cd","Size":"9MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2025.11.01","VibList":[{"Name":"CP068325","Version":"CP068325.10-1OEM.900.0.24580437"}]}],"Installation":{"Command":"hpsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />Offline:</strong></p><ul><li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li></ul><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li><li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li><li>From the same directory, unzip the Smart Component.<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li><li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>To perform the standalone installation, execute the command:</li><li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li><li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:<ul><li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li></ul></li><li>To perform standalone installation of the firmware,Execute the command:<ul><li>./ Execute_Component</li></ul></li><li>Follow the directions given by the Smart Component</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host</li><li>Reboot your system, if required, for the firmware update to take effect</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />オフライン：</strong></p><ul><li>Service Pack ProLiantオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます</li></ul><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデートするESXiホストのIPまたはDNSアドレスを入力するか (ESXiホストがGen9サーバーの場合) 、ESXiホストのiLOのIPまたはDNSアドレスを入力します (サーバーがGen10以上の場合) </li><li>Gen9/Gen10以上に基づいてESXiホスト/iLO認証情報 (rootまたは管理者のユーザー名およびパスワード) を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください：</strong></p><ul><li>vSphereクライアントにログインします。</li><li>インベントリツリーのサーバーまたはクラスターを選択します。</li><li>HPE Insight Managementタブをクリックします。</li><li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li></ul><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>ESXiホスト上のTech Support Modeを有効にします。</li><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>Smartコンポーネント (CPxxxxxx.zip) を一時ディレクトリに置きます。</li><li>同じディレクトリからSmartコンポーネントをunzipします。<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>Smartコンポーネントには、ファームウェアのインストールを実行するためにインストールする必要のあるVIBで構成されたCPxxxxx_VMw.zipが含まれています</li><li>CPxxxxxx_VMw.zipファイルが実行可能であることを確認します。次のコマンドを実行します：<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>スタンドアロンのインストールを行うために、次のコマンドを実行します：</li><li>esxcli software vib install -d /<path_of_CPxxxxxx_VMw.zip>/CPxxxxxx_VMw.zip</li><li>インストールが完了したら、ディレクトリを/opt/Smart_Component/<CPxxxxxx>に変更します。次のコマンドを実行します：<ul><li>cd /opt/Smart_Component/<CPxxxxxx></li></ul></li><li>ファームウェアのスタンドアロンのインストールを行うために、次のコマンドを実行します：<ul><li>./ Execute_Component</li></ul></li><li>Smartコンポーネントの指示に従います。</li><li>ログアウトします。</li><li>ESXiホスト上のTech Support Modeを無効にします。</li><li>必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 9.0"},{"Lang":"ja","Value":"QLogicファイバーチャネルホストバスアダプター for VMware vSphere 9.0用HPEファームウェアフラッシュ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T07:06:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"<p>Fixed the following:</p><ol><li>Windows BitLocker causes the system boot due to ROM signature failure during POST.</li><li>Increase an internal timeout value for SPI/Flash read.</li></ol>","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">アダプター</p></td><td><p dir=\"LTR\">速度</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">ファームウェア</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">ブートBIOS</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBデュアルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBシングルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"<p>以下を修正しました。</p><ol><li>Windows BitLockerにより、POST中にROM署名エラーが発生し、システムが起動します。</li><li>SPI/フラッシュ読み取りの内部タイムアウト値を増やします。</li></ol>","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"<p>Fixed the following:</p><ol><li>Windows BitLocker causes the system boot due to ROM signature failure during POST.</li><li>Increase an internal timeout value for SPI/Flash read.</li></ol>","Lang":"cn"}],"Version":"2025.05.02"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.11.01"}],"SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"515578fa1a934894b2b926c44a093dc2"}]},{"ProductId":"54856ac460a544e2985eadac24abf907","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM2000GEFRA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM2000GEFRA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features&nbsp;for:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features&nbsp;for:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3845960","DateModified":"2025-11-17T10:45:17","FileList":["cp068660.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SAVGRTG9.rel","setup.dll"],"MD5Sum":"a0ae342551b4dd16a736eec4214b6e1e","Name":"cp068660.exe","Release":"2025-11-17T10:40:17","Revision":"E","SHA1Sum":"344bd4f27ab520942eba2ae19f3abf3450e1f6f6","SHA256Sum":"46f8bb53b0ed0589b1b09140f25f7b3ecbc997a745aacd60777403cbb40850ff","Size":"3MB","TargetGUIDs":["002340a5-4d00-324d-3030-304745465241"],"TypeOfChange":"1","Version":"HPG9"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MM2000GEFRA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM2000GEFRAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MM2000GEFRA","TargetGUID":"002340a5-4d00-324d-3030-304745465241","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:55:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG9"}],"SWKeys":[{"Name":"MM2000GEFRA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"20b1a055d4a5499fae9cd0a73758b919"}]},{"ProductId":"36ccc302b9a748a8a9762bf721813e29","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA Drive"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA Drive"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4857656","DateModified":"2025-08-02T21:13:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-1.1/CP067373.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-1.1/WLEBsssATFG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067373.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067373.scexe"],"MD5Sum":"b4d28d359641e031f677eef82625854c","Name":"firmware-hdd-41cdb1c9da_0HPG3-1.1_amd64.deb","Release":"2025-08-03T02:06:35","Revision":"","SHA1Sum":"ad30948033e187d77374b7343224ccee94c77e86","SHA256Sum":"121b1fe8dd6328a591713840e77b65a242060d7fc5ddec8c453943cec8b68487","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP041508.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000GWUDA Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000GWUDA Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000GWUDA","TargetGUID":"4d2340a5-3042-3431-3030-304757554441","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T20:57:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Corrective actions to fix potential background media scan issue.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Corrective actions to fix potential background media scan issue.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Corrective actions to fix potential background media scan issue.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a5a54b9887064197bd2076afeaca5fba"}]},{"ProductId":"a07f8ac11b4a440d99aa61ea5fb0b63f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"},{"Lang":"ja","Value":"<p>この製品には、NICドライバーバージョン233.0.156.0とRoCEドライバーバージョン233.0.156.0が含まれています。</p>"},{"Lang":"cn","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"}],"Files":[{"Bytes":"461107","DateModified":"2025-10-02T08:11:47","FileList":["/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip","/cp068542.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/index.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_235.1.140.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_235.1.140.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/bnxtroce-8990419729759598179.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/bnxtnet--3747714606171988841.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"bea32518f930ce6b9c661c8bcbccf83f","Name":"cp068542.zip","Release":"2025-10-02T08:11:38","Revision":"","SHA1Sum":"2a0c0473d930d9c4ac18f1ae3361df0cf5a809cb","SHA256Sum":"b661130bc243364b404978f8899034206c12d31819756cfe17a8ef5434ff3ce6","Size":"450KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"bnxtroce","Version":"235.1.140.0-1OEM.800.1.0.20613240"},{"Name":"bnxtnet","Version":"235.1.140.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-27T06:15:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where ESXi Datastore not seen when NPAR is enabled.</li><li>This product fixes the issue where PSOD is seen when enable NPAR using 2 NICs.</li></ul><p>&nbsp;</p>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、NPAR が有効な場合に ESXi データストアが表示されない問題を修正します。</li><li>この製品は、2 つの NIC を使用して NPAR を有効にすると PSOD が発生する問題を修正します。</li></ul><p> </p>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where ESXi Datastore not seen when NPAR is enabled.</li><li>This product fixes the issue where PSOD is seen when enable NPAR using 2 NICs.</li></ul><p>&nbsp;</p>","Lang":"cn"}],"Version":"2025.05.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:235.1.240.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtroce:235.1.140.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtnet:235.1.140.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2726ab012ef34fed81d4afe7df3657cd"}]},{"ProductId":"fbb53cf22a594dbb99b8c7f89e562124","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_OCP_4p90_NCSIwPLDMoMCTP_80020F00.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"4.90"}]},"MinimumActiveVersion":"4.20","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA2 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</td><td>80020F00</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in&nbsp;<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28 OCP3アダプター</td><td>80020F00</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.9と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</td><td>80020F00</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in&nbsp;<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"}],"Files":[{"Bytes":"10526588","DateModified":"2025-12-18T07:16:48","FileList":["HPE_E810_XXVDA2_SD_OCP_4p90_NCSIwPLDMoMCTP_80020F00.HPb","HPE_E810_XXVDA2_SD_OCP_4p90_NCSIwPLDMoMCTP_80020F00.xml","payload.json"],"MD5Sum":"78abfda25cad830746f56f2dccb50f50","Name":"HPE_E810_XXVDA2_SD_OCP_4p90_NCSIwPLDMoMCTP_80020F00.fwpkg","Release":"2025-12-18T07:13:35","Revision":"B","SHA1Sum":"28f41957360a03be246c69c3423b53ee8fca07f3","SHA256Sum":"d8dc422cb7278054dbf186c1e7b0b5fb4f686fa07bc3164cabb5c6754b426a40","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860005"],"TypeOfChange":"1","Version":"4.90"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28 OCP3アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-18T06:15:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"},{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"}],"SWKeys":[{"Name":"INTEL_E810_XXV2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"bdc9a8b02b6241b7951dc5b9109c27bd"}]},{"ProductId":"25c9026167b24747b0b74c8f6d82b804","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Ubuntu Linux (x64) - &nbsp;MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li><li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li></ul><p>&nbsp;<strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Ubuntu Linux (x64) - &nbsp;MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li><li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li></ul><p>&nbsp;<strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3971816","DateModified":"2025-07-31T09:57:50","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-1.1/CP067319.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-1.1/KPE60X1GHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067319.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067319.scexe"],"MD5Sum":"b61f274b9e2a023d4666165c260dc5e5","Name":"firmware-hdd-54addf5312_0HPK4-1.1_amd64.deb","Release":"2025-07-31T14:48:22","Revision":"","SHA1Sum":"cfd2b27564c3ec2669e3556f5e431a96745af68f","SHA256Sum":"0852464dc9fcb7d8ea25fee130bd64400c9425a023175d8dbdf1b12f238caf10","Size":"3MB","TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4"}],"Installation":{"Command":"CP041698.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p><p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p><p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK007680KWWFQ","TargetGUID":"562340a5-304b-3730-3638-304b57574651","Type":"nvme"},{"Id":"MK006400KWWFK","TargetGUID":"4d2340a5-304b-3630-3430-304b5757464b","Type":"nvme"},{"Id":"VK003840KWWFP","TargetGUID":"562340a5-304b-3330-3834-304b57574650","Type":"nvme"},{"Id":"MK003200KWWFH","TargetGUID":"4d2340a5-304b-3330-3230-304b57574648","Type":"nvme"},{"Id":"VK001920KWWFN","TargetGUID":"562340a5-304b-3130-3932-304b5757464e","Type":"nvme"},{"Id":"MK001600KWWFF","TargetGUID":"4d2340a5-304b-3130-3630-304b57574646","Type":"nvme"},{"Id":"VK000960KWWFL","TargetGUID":"562340a5-304b-3030-3936-304b5757464c","Type":"nvme"},{"Id":"MK00800KWWFE","TargetGUID":"002340a5-4b4d-3030-3830-304b57574645","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:13:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"703e8c7554a8414c8a902173ea0a4257"}]},{"ProductId":"2ed4fb56e81f45b0b8ae601a61b78e6c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NetXtreme-E NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1187230","DateModified":"2025-12-12T06:49:49","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/bnxt_en.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"MD5Sum":"29c320606a7fdb52f27cf99248774486","Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-235.1.164.14.sles15sp6.x86_64.rpm","Release":"2025-12-12T06:39:05","Revision":"","SHA1Sum":"d75fa719a2ef2e65fd064de05a603d62e2f137dd","SHA256Sum":"45f48267fe99c3ccb37af6c7492102c3e901176d4bdded68bd8e6ea3bf2b3f04","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-235.1.164.14"},{"Bytes":"1193252","DateModified":"2025-12-12T06:54:56","FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/bnxt_en.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"MD5Sum":"db85e4ecac376006396eccb8c30c3568","Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-235.1.164.14.sles15sp7.x86_64.rpm","Release":"2025-12-12T06:39:05","Revision":"","SHA1Sum":"c34416fe998120d01fb11a4374ecd27c56f1d85e","SHA256Sum":"defcf35c66e81501a5fc39e9c406d7ffe22004825631ae2b7155cab57e9a6f32","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-12T04:04:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"1.10.3-235.1.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"1.10.3-235.1.164.14"}],"SWKeys":[{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"417cb571a27e44a5b9cd0ee1e069f9cc"}]},{"ProductId":"07117e80b64248dab9811a2280fcc85e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"ja","Value":"このコンポーネントには、HPE Storageアレイのためのファイバーチャネルホストバスアダプタードライバーサポートを提供する、QLogic Storportドライバーバージョン9.4.11.20が含まれています。"},{"Lang":"cn","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1728232","DateModified":"2026-01-05T06:22:15","FileList":["cp066323.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"MD5Sum":"8bc120ebc74d6cb0ce0f8abe114a01d2","Name":"cp066323.exe","Release":"2026-01-05T06:20:06","Revision":"b","SHA1Sum":"02bf9487c5e3f221af35643099ac5ea301f30f6f","SHA256Sum":"1dcce4ba2c4125b1f26ff8cf0bd38be6c4058846e8828b4e28c8035475247b49","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />[インストール]ボタンをクリックして、インストールを開始します。<br />"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"HPE Storage ファイバーチャネルアダプターキットfor x64 QLogic Storportドライバーfor Microsoft Windows Server 2022"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T14:55:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.11.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.11.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"}],"SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7e1d0f75ed5a42b6bef323ccfb8431c5"}]},{"ProductId":"fde211973c7e4009ac1207f980953529","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GWTHA、VK000960GWTHB、VK001920GWTHC およびVK003840GWTHDドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6002144","DateModified":"2025-09-21T20:04:34","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/CP068907.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/K401HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068907.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068907.scexe"],"MD5Sum":"7cd03bc2c06f21f84f3816c8ba1d0530","Name":"firmware-hdd-492a9952f6-HPG5-5.1.x86_64.rpm","Release":"2025-09-22T00:54:05","Revision":"E","SHA1Sum":"4d01ce997d738d0108847e21fb1f1cccd6fd4646","SHA256Sum":"5521433ec50d0907e4ea8432111d8d87dc90aace20d3c11ea288a913432fc5e7","Size":"5MB","TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"CP041497.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000480GWTHA、VK000960GWTHB、VK001920GWTHCおよびVK003840GWTHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK003840GWTHD","TargetGUID":"562340a5-304b-3330-3834-304757544844","Type":"sata"},{"Id":"VK001920GWTHC","TargetGUID":"562340a5-304b-3130-3932-304757544843","Type":"sata"},{"Id":"VK000960GWTHB","TargetGUID":"562340a5-304b-3030-3936-304757544842","Type":"sata"},{"Id":"VK000480GWTHA","TargetGUID":"562340a5-304b-3030-3438-304757544841","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:46:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5a63b21feb2248f7a2d9ef079143a6ce"}]},{"ProductId":"31e3c0de86a045739aadd70ea35e114f","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U60_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.52 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16814843","DateModified":"2026-01-13T08:07:00","FileList":["payload.json","U60_2.52_01_09_2026.signed.flash","U60_2.52_01_09_2026.xml"],"MD5Sum":"79ca7c92ac559ceb32fc7cc4dfa403f0","Name":"U60_2.52_01_09_2026.fwpkg","Release":"2026-01-13T08:03:49","Revision":"","SHA1Sum":"cfe2b893549b61918c6bf11615eb2fe97989190d","SHA256Sum":"dc0231f8e6a3dad558519bd29f13d996ab64817fba2b1162c99af49e46776f1d","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.52_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Proliant DL20 Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL20 Gen10 Plus サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Proliant DL20 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T06:08:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.708（2.50_07_25_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"Implemented improvements to enhance user experience and optimize functionality.","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"Implemented improvements to enhance user experience and optimize functionality.","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"Implemented improvements to enhance user experience and optimize functionality.","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_01-09-2026"}],"SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"0bda68cec50448d1a235fdf4bee72151"}]},{"ProductId":"bdb6e242313a47b89b69823cf9ad3729","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor."},{"Lang":"ja","Value":"このコンポーネントは、プロセッサー内のデバイスを識別するためのドライブなしのINFをインストールします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"675008","DateModified":"2025-11-18T08:42:18","FileList":["cp069741.xml","cpqsetup.exe","installer.dll","pnp/","pnp/AMDCCP.cat","pnp/AMDCCP.inf","pnp/amddrtm.cat","pnp/amddrtm.dll","pnp/amddrtm.inf","pnp/AMDPCIDev.cat","pnp/AMDPCIDev.inf","pnp/amdpsp.cat","pnp/amdpsp.inf","pnp/SMBUSamd.cat","pnp/SMBUSamd.inf"],"MD5Sum":"723fa3cbe39f426f7a2ee32f7ef69fa9","Name":"cp069741.exe","Release":"2025-11-18T08:40:19","Revision":"E","SHA1Sum":"a8fb995fde69f666c46ba8e6fbc20ae234871d53","SHA256Sum":"60cb85cbb6b6549380e204a2214335105db2e2eae9c30ab53ad813064062234a","Size":"659KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"1","Version":"6.10.8.431"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows Server 2022 and 2025"},{"Lang":"ja","Value":"AMD EPYC プロセッサー（第3世代）識別子for Microsoft Windows Server 2022および2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T08:36:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.10.8.431"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.10.8.431"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"04f87cceff14489ab59f8885137cf80f"}]},{"ProductId":"90a21d24fe854b07a035a8e7bf0e3602","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b59445a4b","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b59445a52","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b59445a54","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b59445a55","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b59445a48","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3533-364b59445a51","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b59445a4c","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b59445a4e","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b59445a50","Version":"HPK1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します: MO000800KYDZK、MO001600KYDZR、MO003200KYDZT、MO006400KYDZU、VO000960KYDZH、VO001920KYDZL、VO003840KYDZN、VO001536KYDZQ、VO007680KYDZP"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>Changes and improvements made in HPK1 are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付：<br />     </strong>HPK1</p><p><strong>最新の推奨またはクリティカルバージョン：</strong><br />     なし</p><p><strong>前のファームウェアバージョン：</strong><br />     なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li><p>HPK1では、変更点および改善点として、Gen11 x2直接接続システムでドライブの内部PHYレジスタ値を変更することにより、受信信号を強化しています。</p></li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>Changes and improvements made in HPK1 are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2256111","DateModified":"2024-04-24T04:35:15","FileList":["Micron_7500_Micron_7500_M7500ALLHPK1.HPb","Micron_7500_Micron_7500_M7500ALLHPK1.xml","payload.json"],"MD5Sum":"861573162c1915d9fba73550d82ed8fe","Name":"Micron_7500_Micron_7500_M7500ALLHPK1.fwpkg","Release":"2024-06-04T00:00:00","Revision":"","SHA1Sum":"b30a9dd549c0c527a638bdcdbe3d3cfcd4b3e63d","SHA256Sum":"46aeb5ac6f3b0acaf1d03687c838b2d49ed9b309226789972b031c909404b772","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304b59445a4b","4d2340a5-304f-3130-3630-304b59445a52","4d2340a5-304f-3330-3230-304b59445a54","4d2340a5-304f-3630-3430-304b59445a55","562340a5-304f-3030-3936-304b59445a48","562340a5-304f-3130-3533-364b59445a51","562340a5-304f-3130-3932-304b59445a4c","562340a5-304f-3330-3834-304b59445a4e","562340a5-304f-3730-3638-304b59445a50"],"TypeOfChange":"1","Version":"HPK1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO000800KYDZK、MO001600KYDZR、MO003200KYDZT、MO006400KYDZU、VO000960KYDZH、VO001920KYDZL、VO003840KYDZN、VO001536KYDZQ、VO007680KYDZP"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO006400KYDZU","TargetGUID":"4d2340a5-304f-3630-3430-304b59445a55","Type":"nvme"},{"Id":"MO003200KYDZT","TargetGUID":"4d2340a5-304f-3330-3230-304b59445a54","Type":"nvme"},{"Id":"MO001600KYDZR","TargetGUID":"4d2340a5-304f-3130-3630-304b59445a52","Type":"nvme"},{"Id":"MO000800KYDZK","TargetGUID":"4d2340a5-304f-3030-3830-304b59445a4b","Type":"nvme"},{"Id":"VO007680KYDZP","TargetGUID":"562340a5-304f-3730-3638-304b59445a50","Type":"nvme"},{"Id":"VO003840KYDZN","TargetGUID":"562340a5-304f-3330-3834-304b59445a4e","Type":"nvme"},{"Id":"VO001920KYDZL","TargetGUID":"562340a5-304f-3130-3932-304b59445a4c","Type":"nvme"},{"Id":"VO000960KYDZH","TargetGUID":"562340a5-304f-3030-3936-304b59445a48","Type":"nvme"},{"Id":"VO001536KYDZQ","TargetGUID":"562340a5-304f-3130-3533-364b59445a51","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-07T09:24:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Changes and improvements made in HPK1&nbsp;are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>HPK1では、変更点および改善点として、Gen11 x2直接接続システムでドライブの内部PHYレジスタ値を変更することにより、受信信号を強化しています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Changes and improvements made in HPK1&nbsp;are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</li></ul>","Lang":"cn"}],"Version":"HPK1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Changes and improvements made in HPK1&nbsp;are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>HPK1では、変更点および改善点として、Gen11 x2直接接続システムでドライブの内部PHYレジスタ値を変更することにより、受信信号を強化しています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Changes and improvements made in HPK1&nbsp;are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</li></ul>","Lang":"cn"}],"Version":"HPK1"}],"SWKeys":[{"Name":"MO000800KYDZK","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KYDZR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYDZT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYDZU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KYDZH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYDZL","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYDZN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYDZP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001536KYDZQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"738d3ecbd42b4b8d832987815cfae4d4"}]},{"ProductId":"e1ccea24a14a427dabc2aadd846feea9","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities."},{"Lang":"ja","Value":"iLO 5 Channel Interfaceドライバーは、iLO 5管理コントローラーとの通信を行うことを可能にするソフトウェアです。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"579888","DateModified":"2025-11-17T07:15:17","FileList":["cp069698.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"MD5Sum":"5885335e0c2864eca446e604e7c80403","Name":"cp069698.exe","Release":"2025-11-17T07:13:05","Revision":"F","SHA1Sum":"3780ab469631b30cf66561d02966a70613edbfd4","SHA256Sum":"014ac7257bb6c23c491bb56b6497ea3708b4665f1eaee2710ffa70a4a394ab12","Size":"566KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.1.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2016 and 2019"},{"Lang":"ja","Value":"iLO 5チャネルインターフェイスドライバーfor Microsoft Windows Server 2016および2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-17T07:00:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SBOM要件をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"}],"SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"05da01a50f8d4475a07703fd7a94ee16"}]},{"ProductId":"c47b4b11bb744418a62b9ae668fd0ea6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC およびMO001920JWWWV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA,&nbsp; EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA,&nbsp; EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5137387","DateModified":"2025-09-21T21:13:31","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/CP068919.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/KAPM5ALSHPDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068919.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068919.scexe"],"MD5Sum":"f9bfed019ff6dc3582aa7196964914a7","Name":"firmware-hdd-9ad359dac1-HPDB-5.1.x86_64.rpm","Release":"2025-09-22T02:03:16","Revision":"E","SHA1Sum":"14041dc9441d51b991ae6df6f72ebc0a1c49f39f","SHA256Sum":"af3b72a13526c8d4f1efb6a3cc348f20cd4cd8f4044e559501322b932703775e","Size":"4MB","TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"CP040601.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"},{"Lang":"ja","Value":"オンライン HDD/SSDフラッシュコンポーネントfor Linux (x64) - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、 MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、 MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO007680JWTBP","TargetGUID":"562340a5-304f-3730-3638-304a57544250","Type":"sas"},{"Id":"MO006400JWTCD","TargetGUID":"4d2340a5-304f-3630-3430-304a57544344","Type":"sas"},{"Id":"VO003840JWTBN","TargetGUID":"562340a5-304f-3330-3834-304a5754424e","Type":"sas"},{"Id":"MO003200JWTBU","TargetGUID":"4d2340a5-304f-3330-3230-304a57544255","Type":"sas"},{"Id":"EO003200JWTCC","TargetGUID":"452340a5-304f-3330-3230-304a57544343","Type":"sas"},{"Id":"VO001920JWTBL","TargetGUID":"562340a5-304f-3130-3932-304a5754424c","Type":"sas"},{"Id":"MO001600JWTBT","TargetGUID":"4d2340a5-304f-3130-3630-304a57544254","Type":"sas"},{"Id":"EO001600JWTCB","TargetGUID":"452340a5-304f-3130-3630-304a57544342","Type":"sas"},{"Id":"VO000960JWTBK","TargetGUID":"562340a5-304f-3030-3936-304a5754424b","Type":"sas"},{"Id":"MO000800JWTBR","TargetGUID":"4d2340a5-304f-3030-3830-304a57544252","Type":"sas"},{"Id":"EO000800JWTCA","TargetGUID":"452340a5-304f-3030-3830-304a57544341","Type":"sas"},{"Id":"MO000400JWTBQ","TargetGUID":"4d2340a5-304f-3030-3430-304a57544251","Type":"sas"},{"Id":"EO000400JWTBV","TargetGUID":"452340a5-304f-3030-3430-304a57544256","Type":"sas"},{"Id":"MO001920JWWWV","TargetGUID":"4d2340a5-304f-3130-3932-304a57575756","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:59:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d11dc139e4384368a01dad304534da0b"}]},{"ProductId":"44ae296c36cb4decaa8bbd5cfce5396e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;-&nbsp;MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;-&nbsp;MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5363732","DateModified":"2025-08-02T21:25:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-1.1/CP067375.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-1.1/PCHFA2B3.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067375.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067375.scexe"],"MD5Sum":"9e25135bc425321d595226c84615e3fd","Name":"firmware-hdd-d550523365_0HPD3-1.1_amd64.deb","Release":"2025-08-03T02:19:37","Revision":"","SHA1Sum":"d088b66772f4de8f154de4cb21ef5d8a7985e0f2","SHA256Sum":"ebba8d6ff89f3e4001bd3e3013019d5ef2a7104674c52990a2041f7af6c6ff7d","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB016000JXLBA","TargetGUID":"4d2340a5-3042-3631-3030-304a584c4241","Type":"sas"},{"Id":"MB018000JXLAU","TargetGUID":"4d2340a5-3042-3831-3030-304a584c4155","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:00:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b08bc18464a74808a9489c7e6efe800c"}]},{"ProductId":"63976963938d4f79be04f7b652abb966","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4331448","DateModified":"2025-11-17T08:24:14","FileList":["cp068659.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SMOBULABPSD2.rel"],"MD5Sum":"f2d318ee81108c24a6fe4ba8c32982ac","Name":"cp068659.exe","Release":"2025-11-17T08:17:46","Revision":"J","SHA1Sum":"af6ea578929b6ee878c66beca85c3a65bba7cca4","SHA256Sum":"dac205138011be8e9ea207df82eee79d86ed2d02409c0c4ecd17016ae470a7a0","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000JWRTH","TargetGUID":"4d2340a5-3042-3431-3030-304a57525448","Type":"sas"},{"Id":"MB012000JWRTF","TargetGUID":"4d2340a5-3042-3231-3030-304a57525446","Type":"sas"},{"Id":"MB010000JWRTE","TargetGUID":"4d2340a5-3042-3031-3030-304a57525445","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:53:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.<br />&nbsp;</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました<br /> </li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.<br />&nbsp;</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7d67acb393844eddb9adb9967c42ac81"}]},{"ProductId":"25afa565c5cd4e359629eee44baf7e64","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U39_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11738720","DateModified":"2026-01-13T20:40:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.62_2026_01_09-1.1/CP070353.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.62_2026_01_09-1.1/U39_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070353.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070353.scexe"],"MD5Sum":"96ba6362116f12597de1f4e3c6b29a8c","Name":"firmware-system-u39-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-14T02:30:57","Revision":"","SHA1Sum":"18e52b52efb74dc9c82fa05d75b88454faba06b0","SHA256Sum":"275f862940b272cbb2ef263bc054e7e1f1cf48b1e22af633a518037eb854baf2","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合:<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:33:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"380cc747b4dc404998a6462b4cdd39cf"}]},{"ProductId":"32e70edc717a4f199fb4d966f5a2ab73","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. SSASCRIPTING - Scripting can be performed in offline or online environments.  The SSA Scripting application has 2 scripting modes – Capture and Input."},{"Lang":"ja","Value":"Smart Storage Administrator CLI（SSACLI）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるコマンドラインベースのディスク構成プログラムです。SSASCRIPTING - スクリプトは、オフラインまたはオンライン環境で実行することができます。SSAスクリプティングアプリケーションは、2つのスクリプティングモード - CaptureおよびInputを持っています。"},{"Lang":"cn","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. SSASCRIPTING - Scripting can be performed in offline or online environments.  The SSA Scripting application has 2 scripting modes – Capture and Input."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"10409002","DateModified":"2026-01-19T02:10:36","FileList":["./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-6.60-8.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/doc/ssacli/changelog.Debian.gz","./usr/share/doc/ssacli/copyright","./usr/share/man/man8/ssacli.8.gz","./usr/share/smartupdate/ssacli/component.xml"],"MD5Sum":"636fe71f52c81d942bd6575714bbdf95","Name":"ssacli-6.60-8.0_amd64.deb","Release":"2026-01-19T02:10:05","Revision":"","SHA1Sum":"9cb9668536c5f80c5c88bc03be41dd710893b19d","SHA256Sum":"cd6cb8ae6f6fcbf68f5568b44e2098aec7f82fbc15e4aff3463f673f36d51854","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"TypeOfChange":"1","Version":"6.60.8.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>If there is an older version of SSACLI installed on the system, please use &quot;dpkg -r &lt;package-name&gt;&quot; &nbsp;to remove configuration files and&nbsp;dpkg --purge &lt;package-name&gt;&nbsp; to&nbsp;remove completely.</li><li>Use &quot;sudo dpkg -i&nbsp;&nbsp; &lt;package-name&gt;&nbsp;&quot;&nbsp; &nbsp;to install the application.</li><li>The software resides in &nbsp;/opt/smartstorageadmin/ssacli and the executable name is ssacli which is located in /usr/sbin.</li></ul><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>システムにSSACLIの古いバージョンがインストールされている場合は、「dpkg -r <パッケージ名>設定ファイルを削除し、dpkg --purge <パッケージ名> 完全に削除します。</li><li>アプリケーションをインストールするために、「sudo dpkg -i <package-name>」を使用します。</li><li>このソフトウェアは/opt/smartstorageadmin/ssacliにあり、実行可能ファイル名は/usr/sbinに配置されているssacliです。</li></ul><p> </p><p> </p>"},{"Lang":"cn","Value":"<ul><li>If there is an older version of SSACLI installed on the system, please use &quot;dpkg -r &lt;package-name&gt;&quot; &nbsp;to remove configuration files and&nbsp;dpkg --purge &lt;package-name&gt;&nbsp; to&nbsp;remove completely.</li><li>Use &quot;sudo dpkg -i&nbsp;&nbsp; &lt;package-name&gt;&nbsp;&quot;&nbsp; &nbsp;to install the application.</li><li>The software resides in &nbsp;/opt/smartstorageadmin/ssacli and the executable name is ssacli which is located in /usr/sbin.</li></ul><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11コントローラー"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:25:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"cn"}],"Version":"6.50.11.0"},{"ReleaseNotes":[{"Enhancements":"<ul style=\"list-style-type:disc\"><li>Modified the SSACLI component version format to meet the new requirement from VMware ESXi for 9.1</li><li>Added spare type decoding in Array Diagnostic Utility (ADU) reports to indicate whether a logical drive uses dedicated or auto-replace spares</li><li>Modified the default strip size for NVMe drives based on the Maximum Data Transfer Size (MDTS), and tools will set the default strip size to the minimum supported MDTS value when creating or migrating a logical drive</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul style=\"list-style-type:disc\"><li>Modified the SSACLI component version format to meet the new requirement from VMware ESXi for 9.1</li><li>Added spare type decoding in Array Diagnostic Utility (ADU) reports to indicate whether a logical drive uses dedicated or auto-replace spares</li><li>Modified the default strip size for NVMe drives based on the Maximum Data Transfer Size (MDTS), and tools will set the default strip size to the minimum supported MDTS value when creating or migrating a logical drive</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul style=\"list-style-type:disc\"><li>Modified the SSACLI component version format to meet the new requirement from VMware ESXi for 9.1</li><li>Added spare type decoding in Array Diagnostic Utility (ADU) reports to indicate whether a logical drive uses dedicated or auto-replace spares</li><li>Modified the default strip size for NVMe drives based on the Maximum Data Transfer Size (MDTS), and tools will set the default strip size to the minimum supported MDTS value when creating or migrating a logical drive</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.60.8.0"}],"SWKeys":[{"Name":"ssacli","SWKeyExpectedPath":"software:deb"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6d7d824703a54b4eb0ddfa9e33236529"}]},{"ProductId":"fde13e5a19194ad9adab9161f8d35a15","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Provides proactive protection against contamination built up on the media and air-bearing surface of the heads by increased routine &ldquo;sweeping&rdquo; of the media surface.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Provides proactive protection against contamination built up on the media and air-bearing surface of the heads by increased routine &ldquo;sweeping&rdquo; of the media surface.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3551952","DateModified":"2025-08-02T22:09:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-1.1/CP067390.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-1.1/TA14SXe0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067390.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067390.scexe"],"MD5Sum":"03ea0e19c2f74bccbc02ddd4400de142","Name":"firmware-hdd-c7df7ceedb_0HPD9-1.1_amd64.deb","Release":"2025-08-03T03:02:38","Revision":"","SHA1Sum":"421f49d3e16152736e45e0d428e45031a9bac2e2","SHA256Sum":"725936acef8d7b196f72758a1a92a0aa56cc358e9e687d3f445e7e2bdc937934","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP041670.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000600JWHPH","TargetGUID":"452340a5-3048-3030-3630-304a57485048","Type":"sas"},{"Id":"EH000900JWHPK","TargetGUID":"452340a5-3048-3030-3930-304a5748504b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:32:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"234715b12d774bb5b0159bcadbca8225"}]},{"ProductId":"fc90f99dec3d4432a73ac738a336cdc1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and 6 (iLO 5, 6 and 7) Embedded Health and Alerting."},{"Lang":"ja","Value":"Agentless Management Service（AMSD）は、Integrated Lights Out 5、6および7（iLO 5、6および7）内蔵ヘルスおよびアラートのサポートを提供します。"},{"Lang":"cn","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and 6 (iLO 5, 6 and 7) Embedded Health and Alerting."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9956227","DateModified":"2026-01-09T03:03:24","FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/0d","./usr/lib/.build-id/0d/10abaf423810b9f74073a8ded99d7ec1e23872","./usr/lib/.build-id/0d/10abaf423810b9f74073a8ded99d7ec1e23872.1","./usr/lib/.build-id/25","./usr/lib/.build-id/25/2ed6965ee27f9f65b30fdb34470997a3b13a5d","./usr/lib/.build-id/41","./usr/lib/.build-id/41/e475ed1c45cee18d01421697ba171ebe0532d1","./usr/lib/.build-id/41/e475ed1c45cee18d01421697ba171ebe0532d1.1","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/c3e85ae0643cd9dfffd6a8a013f55e7a4e0c87","./usr/lib/.build-id/a0","./usr/lib/.build-id/a0/ab0d3cad0f4f18f5d14e02d92e7ef86b5f6107","./usr/lib/.build-id/a0/ab0d3cad0f4f18f5d14e02d92e7ef86b5f6107.1","./usr/lib/.build-id/b2","./usr/lib/.build-id/b2/7b8c72d2519de5b6952f9f9bd2dbfc69690d72","./usr/lib/.build-id/b2/7b8c72d2519de5b6952f9f9bd2dbfc69690d72.1","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/f268db4b494b7b4be055f3e780ca91c889bc21","./usr/lib/.build-id/c9/f268db4b494b7b4be055f3e780ca91c889bc21.1","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/d6642be4b02f869995293aed400cef88abb3d6","./usr/lib/.build-id/f1","./usr/lib/.build-id/f1/58e6e7cd6f5a778bcaeb4f9815b83e92899bd3","./usr/lib/.build-id/f1/58e6e7cd6f5a778bcaeb4f9815b83e92899bd3.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"MD5Sum":"35d0ed678a575d0c6698d0e46dc320cc","Name":"amsd-4.5.0-2107.2.rhel10.x86_64.rpm","Release":"2026-01-09T08:57:05","Revision":"","SHA1Sum":"32a73f71fb5da98bbaeea991de295c533d41d0c8","SHA256Sum":"1dcc8dd20364833d453985d1b4071f1400c810199b03ab76a4cdf54fb46d1072","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.5.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 10 Server"},{"Lang":"ja","Value":"Agentless Management Service (iLO 5、iLO 6およびiLO 7) for Red Hat Enterprise Linux 10 Server"},{"Lang":"cn","Value":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 10 Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330615903307","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330715903307","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-08T08:45:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"4.4.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"4.5.0"}],"SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U74","Model":"HPE ProLiant Compute XD230 (U74)"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"66307d72ad4a44f2872b8c8fbb857b13"}]},{"ProductId":"6d1ce52e0d6c4c48a4cc6f903852d87d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U47_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34239352","DateModified":"2026-01-14T05:49:10","FileList":["cp070296.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U47_2.54_01_09_2026.signed.flash"],"MD5Sum":"83de2123ff2f6e39e7f0825f175a0dc6","Name":"cp070296.exe","Release":"2026-01-14T05:46:41","Revision":"","SHA1Sum":"2ba4f00b800a209c5de539ecdc0d1f845ceaaf64","SHA256Sum":"b5e7d70da82c93056c6d39a6483ea0fce15c2bcb593b76bf0e776cff94c18ae0","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1Uノードおよび2Uノード受注構成サーバー(U47) "},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T07:36:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"86c6a30ddec54f759ee2ce126d557ef5"}]},{"ProductId":"56422dc0cdb64171addc0c9909a7019a","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp067979.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.802"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9053856","DateModified":"2025-11-14T02:36:20","FileList":["cp067979.compsig","cp067979.zip","cp069583.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"a380ccc42306c5c92fc48b1cb9cd487c","Name":"cp069583.exe","Release":"2025-11-14T02:34:51","Revision":"B","SHA1Sum":"0def5661ec76296d08d58b8ed10962ac37e547ad","SHA256Sum":"3b836dfb3266ca2efc414eb988691eae4c5a5fe15328fcc6759b4a4be6cb0375","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.802"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services（SPS）ファームウェアfor HPE Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T02:33:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 04.04.04.802 (2.50_07_24_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.04.04.802 (2.50_07_24_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Server Platform Servicesファームウェアのこのリビジョンは、CVE-2025-20067として文書化されているセキュリティ上の脆弱性を緩和します。この問題は、HPEサーバーに固有のものではありません。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 04.04.04.802 (2.50_07_24_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"04.04.04.802"},{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 04.04.04.802 (2.50_07_24_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.04.04.802 (2.50_07_24_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Server Platform Servicesファームウェアのこのリビジョンは、CVE-2025-20067として文書化されているセキュリティ上の脆弱性を緩和します。この問題は、HPEサーバーに固有のものではありません。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 04.04.04.802 (2.50_07_24_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"04.04.04.802"}],"SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a0c3d168572b48d3a6ff85d62c1ff987"}]},{"ProductId":"6a4f9209b5474891beaf50886f41470e","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4T adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4T_O_SEC_4p90_PLDMoMCTP_80020EF5.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-15938086000e","Version":"4.90"}]},"MinimumActiveVersion":"4.20","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4T Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA4T Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4T Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter for HPE</td><td>80020EF5</td><td>1.3863.0</td><td>4.90</td></tr><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK NG Adapter for HPE</td><td>80020EF5</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 MCLKアダプターfor HPE</td><td>80020EF5</td><td>1.3863.0</td><td>4.90</td></tr><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 MCLK NGアダプターfor HPE</td><td>80020EF5</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.9と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter for HPE</td><td>80020EF5</td><td>1.3863.0</td><td>4.90</td></tr><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK NG Adapter for HPE</td><td>80020EF5</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"}],"Files":[{"Bytes":"10524451","DateModified":"2025-12-18T07:23:58","FileList":["HPE_E810_XXV4T_O_SEC_4p90_PLDMoMCTP_80020EF5.HPb","HPE_E810_XXV4T_O_SEC_4p90_PLDMoMCTP_80020EF5.xml","payload.json"],"MD5Sum":"7012aeaef4cc30e5f2bb4e15b5dba435","Name":"HPE_E810_XXV4T_O_SEC_4p90_PLDMoMCTP_80020EF5.fwpkg","Release":"2025-12-18T07:20:42","Revision":"B","SHA1Sum":"6b76ab8a651e7079291437ca2f8936f36a988425","SHA256Sum":"1880ef73efb198974551a8b1691addcb3fd1a85e5c8cd8906be02ceaa226cb7a","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000e"],"TypeOfChange":"1","Version":"4.90"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter "},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 MCLKアダプター "},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-18T06:15:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"},{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"}],"SWKeys":[{"Name":"INTEL_E810_XXV4T_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"1df1d3ff1185490f9ec18bb596489941"}]},{"ProductId":"b929c06b33df46a182acd3e907e0dc53","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.5"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4588608","DateModified":"2025-11-19T06:25:14","FileList":["cp068480.xml","cpqsetup.exe","elxflashStandalone-windows-14.4.731.5-1/firmware/","elxflashStandalone-windows-14.4.731.5-1/firmware/B1447315.grp","elxflashStandalone-windows-14.4.731.5-1/firmware/P1447315.grp","elxflashStandalone-windows-14.4.731.5-1/win/","elxflashStandalone-windows-14.4.731.5-1/win/elxflash.bat","elxflashStandalone-windows-14.4.731.5-1/win/winlpcfg.bat","elxflashStandalone-windows-14.4.731.5-1/win/x64/","elxflashStandalone-windows-14.4.731.5-1/win/x64/elxflash.exe","elxflashStandalone-windows-14.4.731.5-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-14.4.731.5-1/win/x64/libdfc.dll","elxflashStandalone-windows-14.4.731.5-1/win/x64/readme.txt","elxflashStandalone-windows-14.4.731.5-1/win/x64/RM.INI","elxflashStandalone-windows-14.4.731.5-1/win/x64/WinLpCfg.exe","fwmatrix.txt","elxflashStandalone-windows-14.4.731.5-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","reference.xml"],"MD5Sum":"28ad54e662c86286c3b08a1f7261081a","Name":"cp068480.exe","Release":"2025-11-19T06:10:00","Revision":"","SHA1Sum":"60335f203f4a6b4ccc44db711dfea8925eadc3d6","SHA256Sum":"e054096c73169ac73afb19c3ac627eca7c7e0bbdf07579c83c5c17198795952a","Size":"4MB","TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2025.11.01"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<br />ダウンロードされたファイルは、コンポーネント番号をファイル名に持つ自己解凍型実行可能ファイルです。<br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />［インストール］ボタンをクリックして、インストールを開始します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2016/2019/2022/2025 x64"},{"Lang":"ja","Value":"HPEファームウェアフラッシュfor Emulexファイバーチャネルホストバスアダプター - Microsoft Windows Server 2016/2019/2022/2025 x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-21T09:55:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>Fixed the Following:</p><ol><li>Switch Login Incomplete After Firmware Upgrade</li><li>Boot Incomplete on RHEL 10</li></ol>","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>以下を修正しました。</p><ol><li>ファームウェアのアップグレード後にスイッチのログインが完了できない</li><li>RHEL 10でブートが完了できない</li></ol>","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>Fixed the Following:</p><ol><li>Switch Login Incomplete After Firmware Upgrade</li><li>Boot Incomplete on RHEL 10</li></ol>","Lang":"cn"}],"Version":"2025.09.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.11.01"}],"SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"5d5483b2796f4400add5ab4e7a1c9ae3"}]},{"ProductId":"eca7d77c8ba84ffe9014dfb5c3b6ee15","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWCPK、EH000600JWCPL、EH000300JWCPN、EH000300JXLVR、EH000600JXLVT、EH000900JXLVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5932993","DateModified":"2025-09-21T22:09:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/CP068928.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/SKESTNDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068928.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068928.scexe"],"MD5Sum":"df482eb691c005b5423f217ac6840811","Name":"firmware-hdd-3d97759111-HPDB-4.1.x86_64.rpm","Release":"2025-09-22T02:58:48","Revision":"D","SHA1Sum":"03e418dd9e18a64ca36a73dbe171e7f3025b27fb","SHA256Sum":"229c510bc0484c83a07d7565c164a30553463f4144cc94f6f51e23d39a39671c","Size":"5MB","TargetGUIDs":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"CP040309.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EH000300JWCPK、EH000600JWCPL、EH000900JWCPN、EH000300JXLVR、EH000600JXLVT、およびEH000900JXLVUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000300JWCPK","TargetGUID":"452340a5-3048-3030-3330-304a5743504b","Type":"sas"},{"Id":"EH000600JWCPL","TargetGUID":"452340a5-3048-3030-3630-304a5743504c","Type":"sas"},{"Id":"EH000900JWCPN","TargetGUID":"452340a5-3048-3030-3930-304a5743504e","Type":"sas"},{"Id":"EH000900JXLVU","TargetGUID":"452340a5-3048-3030-3930-304a584c5655","Type":"sas"},{"Id":"EH000300JXLVR","TargetGUID":"452340a5-3048-3030-3330-304a584c5652","Type":"sas"},{"Id":"EH000600JXLVT","TargetGUID":"452340a5-3048-3030-3630-304a584c5654","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:10:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"de21450efdd548ebb29ded49e6e88ec9"}]},{"ProductId":"930ec7c21c864080921bd1f4201e5153","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of SSA, with the appropriate firmware."},{"Lang":"ja","Value":"Smart Storage Administrator（SSA）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるWebベースのアプリケーションです。Smart Array Advanced Pack 1.0および2.0の機能は、適切なファームウェア(の使用)によりSSAのベースライン機能の一部となりました。"},{"Lang":"cn","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of SSA, with the appropriate firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"7578550","DateModified":"2026-01-19T01:35:54","FileList":["./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/sbin/ssa","./usr/share/doc/ssa/changelog.Debian.gz","./usr/share/doc/ssa/copyright","./usr/share/man/man8/ssa.8.gz","./usr/share/smartupdate/ssa/component.xml"],"MD5Sum":"4355d9af19025b55a5c781089e60ef12","Name":"ssa-6.60-8.0_amd64.deb","Release":"2026-01-19T01:35:24","Revision":"","SHA1Sum":"051f19b821f047fa6d97c1a3fef13387a2cdd812","SHA256Sum":"86b5ee9cd8579bb88e12ded80c7dd039af7ee94e27b11c7e8c4f056e2ae15239","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"TypeOfChange":"1","Version":"6.60.8.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Supported Client Side Browsers<br />------------------------------------<br />&nbsp; Mozilla Firefox 9.0 or later<br />&nbsp; Google Chrome<br />&nbsp; Microsoft Internet Explorer 9.0 or above<br />&nbsp; * Please make sure the following browser options are enabled:<br />&nbsp; &nbsp; 1. Automatically load images and other data types.<br />&nbsp; &nbsp; 2. JavaScript.<br />&nbsp; &nbsp; 3. Style sheets.</p><p>&nbsp;</p><p>Installing and running Smart Storage Administrator<br />--------------------------------------------------------<br />&nbsp; Installation:</p><ul><li>If there is an older version of SSA&nbsp;installed on the system, please use &quot;dpkg -r &lt;package-name&gt;&quot; &nbsp;to remove configuration files and dpkg --purge &lt;package-name&gt; &nbsp;to remove completely.</li><li>Use &quot;sudo dpkg -i&nbsp;&lt;package-name&gt;&quot; to install the application.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul><p>&nbsp; Run the SSA client on the local server as an application:<br />&nbsp; &nbsp; Requirements:<br />&nbsp; &nbsp; &nbsp; &nbsp;. You must run ssa as root<br />&nbsp; &nbsp; &nbsp; &nbsp;. The background process will create a port on the loopback interface&nbsp;which is not visible to external network connections.<br />&nbsp; &nbsp; 1. Run the ssa command (/usr/sbin/ssa) with the &quot;-local&quot; parameter. The<br />&nbsp; &nbsp; &nbsp; &nbsp;background program will start and launch the firefox browser.<br />&nbsp; &nbsp; 2. To change the default browser that is started, or to specify the command<br />&nbsp; &nbsp; &nbsp; &nbsp;to use to launch the browser, modify the browserstart.sh script<br />&nbsp; &nbsp; &nbsp; &nbsp;(under /opt/smartstorageadmin/ssa/bin) with the correct path.<br />&nbsp; &nbsp; 3. To exit the application, close the main application window.</p><p>&nbsp;</p><p><!--StartFragment --></p><p>Note: SSA required the root privileges. If you are not logged in as the root user, please use the command below to grant root permissions before launching the local application.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &ldquo;xhost +si:localuser:root&rdquo;</p><p><!--EndFragment --></p>"},{"Lang":"ja","Value":"<p>サポートされているクライアント側ブラウザー<br />------------------------------------<br />  Mozilla Firefox 9.0以降<br />  Google Chrome<br />  Microsoft Internet Explorerバージョン9.0以降<br />  次のブラウザーオプションが使用可能であることを確認してください。<br />    1. イメージと他のデータタイプを自動的にロードします。<br />    2. JavaScript。<br />    3. スタイルシート。</p><p> </p><p>Smart Storage Administratorのインストールと実行<br />--------------------------------------------------------<br />  インストール：</p><ul><li>システムにSSAの古いバージョンがインストールされている場合は、「dpkg -r <パッケージ名>設定ファイルを削除し、dpkg --purge <パッケージ名> 完全に削除します。</li><li>アプリケーションをインストールするために、「sudo dpkg -i <package-name>」を使用します。</li><li>このソフトウェアは/opt/smartstorageadmin/ssaにあり、実行可能ファイル名は/usr/sbinに配置されているssaです。</li></ul><p>  ローカル サーバー上で SSA クライアントをアプリケーションとして実行します。<br />    要件:<br />       ssaをrootとして実行する必要があります<br />       バックグラウンド プロセスは、外部ネットワーク接続からは見えないループバック インターフェイス上にポートを作成します。<br />    1. 「-local」パラメーターを指定して ssa コマンド (/usr/sbin/ssa) を実行します。Hewlett <br />       バックグラウンド プログラムが起動し、Firefox ブラウザーが起動します。<br />    2. 起動時のデフォルトブラウザーを変更する場合、またはブラウザー起動に使用するコマンドを<br />       指定する場合は、/opt/smartstorageadmin/ssa/bin 配下の<br />       browserstart.shスクリプトを、正しいパスで修正してください。<br />    3. アプリケーションを終了するには、メインのアプリケーションウィンドウを閉じます。</p><p> </p><p><!--StartFragment --></p><p>注記：SSAにはルート権限が必要です。ルートユーザーとしてログインしていない場合は、ローカルアプリケーションを起動する前に、以下のコマンドを使用してルート権限を付与してください。</p><p>          “xhost +si:localuser:root”</p><p><!--EndFragment --></p>"},{"Lang":"cn","Value":"<p>Supported Client Side Browsers<br />------------------------------------<br />&nbsp; Mozilla Firefox 9.0 or later<br />&nbsp; Google Chrome<br />&nbsp; Microsoft Internet Explorer 9.0 or above<br />&nbsp; * Please make sure the following browser options are enabled:<br />&nbsp; &nbsp; 1. Automatically load images and other data types.<br />&nbsp; &nbsp; 2. JavaScript.<br />&nbsp; &nbsp; 3. Style sheets.</p><p>&nbsp;</p><p>Installing and running Smart Storage Administrator<br />--------------------------------------------------------<br />&nbsp; Installation:</p><ul><li>If there is an older version of SSA&nbsp;installed on the system, please use &quot;dpkg -r &lt;package-name&gt;&quot; &nbsp;to remove configuration files and dpkg --purge &lt;package-name&gt; &nbsp;to remove completely.</li><li>Use &quot;sudo dpkg -i&nbsp;&lt;package-name&gt;&quot; to install the application.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul><p>&nbsp; Run the SSA client on the local server as an application:<br />&nbsp; &nbsp; Requirements:<br />&nbsp; &nbsp; &nbsp; &nbsp;. You must run ssa as root<br />&nbsp; &nbsp; &nbsp; &nbsp;. The background process will create a port on the loopback interface&nbsp;which is not visible to external network connections.<br />&nbsp; &nbsp; 1. Run the ssa command (/usr/sbin/ssa) with the &quot;-local&quot; parameter. The<br />&nbsp; &nbsp; &nbsp; &nbsp;background program will start and launch the firefox browser.<br />&nbsp; &nbsp; 2. To change the default browser that is started, or to specify the command<br />&nbsp; &nbsp; &nbsp; &nbsp;to use to launch the browser, modify the browserstart.sh script<br />&nbsp; &nbsp; &nbsp; &nbsp;(under /opt/smartstorageadmin/ssa/bin) with the correct path.<br />&nbsp; &nbsp; 3. To exit the application, close the main application window.</p><p>&nbsp;</p><p><!--StartFragment --></p><p>Note: SSA required the root privileges. If you are not logged in as the root user, please use the command below to grant root permissions before launching the local application.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &ldquo;xhost +si:localuser:root&rdquo;</p><p><!--EndFragment --></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) for Ubuntu for Gen10/Gen10 Plus/Gen11コントローラー"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:18:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li></ul>","Lang":"cn"}],"Version":"6.50.11.0"},{"ReleaseNotes":[{"Enhancements":"<ul style=\"list-style-type:disc\"><li>Added spare type decoding in Array Diagnostic Utility (ADU) reports to indicate whether a logical drive uses dedicated or auto-replace spares</li><li>Modified the default strip size for NVMe drives based on the Maximum Data Transfer Size (MDTS), and tools will set the default strip size to the minimum supported MDTS value when creating or migrating a logical drive</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul style=\"list-style-type:disc\"><li>Added spare type decoding in Array Diagnostic Utility (ADU) reports to indicate whether a logical drive uses dedicated or auto-replace spares</li><li>Modified the default strip size for NVMe drives based on the Maximum Data Transfer Size (MDTS), and tools will set the default strip size to the minimum supported MDTS value when creating or migrating a logical drive</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul style=\"list-style-type:disc\"><li>Added spare type decoding in Array Diagnostic Utility (ADU) reports to indicate whether a logical drive uses dedicated or auto-replace spares</li><li>Modified the default strip size for NVMe drives based on the Maximum Data Transfer Size (MDTS), and tools will set the default strip size to the minimum supported MDTS value when creating or migrating a logical drive</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.60.8.0"}],"SWKeys":[{"Name":"ssa","SWKeyExpectedPath":"software:deb"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"52828cfeee2f45ba846e927c3996d180"}]},{"ProductId":"9ea83d5d4cdf449690664479d7c8538a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6415951","DateModified":"2025-09-17T12:43:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/CP068842.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/HVLAeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068842.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068842.scexe"],"MD5Sum":"1c0e8b920e1806a10568ded288822713","Name":"firmware-hdd-a886842a99-HPD2-10.1.x86_64.rpm","Release":"2025-09-17T17:33:05","Revision":"J","SHA1Sum":"e266dfe0f7fe8f28c25695965efa3e594d7368a3","SHA256Sum":"c51eb3037ffeeed4b6d3e8ce1962dc8054eeb7eb524bcfa82a46ab047df0ece0","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041488.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB006000JWKGN ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000JWKGN","TargetGUID":"4d2340a5-3042-3630-3030-304a574b474e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T18:35:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5c2b3957b6e54829a9ca2b3d680db848"}]},{"ProductId":"1aa231a863f54088aaed47c33f55bded","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"16711520","DateModified":"2025-07-16T07:20:56","FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"MD5Sum":"1751559cf2464579c3920e96c3c23fcb","Name":"kmod-qlgc-fastlinq-8.76.2.0-1.rhel9u5.x86_64.rpm","Release":"2025-07-16T06:52:13","Revision":"","SHA1Sum":"7684837a2bcc8663154016a70ddda0f645e7e3ec","SHA256Sum":"17c90c98d873095d58978c0e9032588aa2f79f405ce13720045e4998c88f8db4","Size":"15MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.2.0-10"},{"Bytes":"17734580","DateModified":"2025-07-16T07:27:32","FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"MD5Sum":"8ab0f236c8737c925a9b4a131ff26217","Name":"kmod-qlgc-fastlinq-8.76.2.0-10.rhel9u6.x86_64.rpm","Release":"2025-07-16T06:52:13","Revision":"","SHA1Sum":"b07ae84958bfcc6ff5975db3079162f85fdeb777","SHA256Sum":"2b7b77fa43425584fcd4524d660ae09f0f181163546ec50e8dcfd675a8a2157c","Size":"16MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.2.0-10"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE QLogic FastLinQ 10/25/50 GbEドライバーfor Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770070","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770069","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770068","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770071","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770072","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770074","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770073","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-16T03:44:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"<ul><li>This product fixes an issue of PTP hardware timestamp does not function.</li><li>This product fixes an error while reading debugfs attribute do_not_recover.</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、現在Red Hat Enterprise Linux 9.5をサポートします。</p>","Fixes":"<ul><li>この製品は、PTPハードウェアタイムスタンプが機能しない問題を修正します。</li><li>この製品は、debugfs 属性 do_not_recover の読み取り中に発生するエラーを修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"<ul><li>This product fixes an issue of PTP hardware timestamp does not function.</li><li>This product fixes an error while reading debugfs attribute do_not_recover.</li></ul>","Lang":"cn"}],"Version":"8.74.6.0-5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.76.2.0-10"}],"SWKeys":[{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"89dde2a39dfb4d64a8652e6a68b10854"}]},{"ProductId":"7dc47244be094f2084e0e71968443832","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4191060","DateModified":"2025-08-03T01:17:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-1.1/CP067335.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-1.1/KARM5ALSHPD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067335.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067335.scexe"],"MD5Sum":"4c2641eeeda6218b071928348750777d","Name":"firmware-hdd-8fafc9efb2_0HPD8-1.1_amd64.deb","Release":"2025-08-03T06:11:05","Revision":"","SHA1Sum":"7ec704faad50d0beb58cb1bb49a879b659669634","SHA256Sum":"72915e6ecfe2942e7f1ab3de2462a069f29c9e07b427e0a521b8be5c3bdb413e","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP041555.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO007680RWUFC","TargetGUID":"562340a5-304f-3730-3638-305257554643","Type":"sas"},{"Id":"VO003840RWUFF","TargetGUID":"562340a5-304f-3330-3834-305257554646","Type":"sas"},{"Id":"VO003840RWUFB","TargetGUID":"562340a5-304f-3330-3834-305257554642","Type":"sas"},{"Id":"VO001920RWUFE","TargetGUID":"562340a5-304f-3130-3932-305257554645","Type":"sas"},{"Id":"VO001920RWUFA","TargetGUID":"562340a5-304f-3130-3932-305257554641","Type":"sas"},{"Id":"VO000960RWUFD","TargetGUID":"562340a5-304f-3030-3936-305257554644","Type":"sas"},{"Id":"VO000960RWUEV","TargetGUID":"562340a5-304f-3030-3936-305257554556","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:00:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"96c8e9481e97435d8f4f1483ebbb03da"}]},{"ProductId":"aa3d4b3746e2485289f458134b1187cd","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Initial Release</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />     オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーファームウェア</p><p><strong>リリースバージョンおよび/または日付:</strong><br />     NA<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     NA<br /><br /><strong>前のファームウェアバージョン：</strong><br />     NA<br /><br /><strong>ファームウェアの関連性：</strong><br />     なし<br /><br /><strong>改善点/新しい機能：</strong></p><ul><li>最初のリリース</li></ul><p><strong>修正された問題点：</strong></p><p><strong>     </strong>なし</p><p><strong>既知の問題点:</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Initial Release</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"17579607","DateModified":"2025-03-07T08:34:11","FileList":["/CP064920_BUILD_17.data","/CP064920.vmexe","/CP064920.vmexe64","/CP064920.vmfile","/CP064920_VMw.zip","/CP064920.xml","/payload.json","/CP064920_VMw.zip/index.xml","/CP064920_VMw.zip/vendor-index.xml","/CP064920_VMw.zip/metadata.zip","/CP064920_VMw.zip/vib20/CP064920/HPE_bootbank_CP064920_1.27.17-8.0.0.20613240.vib","/CP064920_VMw.zip/metadata.zip/vendor-index.xml","/CP064920_VMw.zip/metadata.zip/vmware.xml","/CP064920_VMw.zip/metadata.zip/vibs/CP064920--5826758252216142537.xml","/CP064920_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064920_1.27.17-8.0.0.20613240.xml"],"MD5Sum":"e9f01041a6480a5b3f146fff648f59b1","Name":"CP064920.zip","Release":"2025-03-07T08:28:31","Revision":"C","SHA1Sum":"f3c397dc352176d2775da2312117cc0a4f74b513","SHA256Sum":"80483b9383a35bd539adfc944c0debebe2f1dcc62360ac5307cbf0159f2d0c2b","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27","VibList":[{"Name":"CP064920","Version":"1.27.17-8.0.0.20613240"}]}],"Installation":{"Command":"CP064920.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":240,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&nbsp; &nbsp; &nbsp; &lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&nbsp; &nbsp; &nbsp; &lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&nbsp; &nbsp; &nbsp; &lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 2000 Gen10 PlusバックプレーンエキスパンダーFW"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"17000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Id":"Apollon2800Gen10Plus","TargetGUID":"","Type":"agp"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-06T03:53:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Update build environment with SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SHA384でカーネル生成環境をアップデートします</li><li>OSをアップデートします</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Update build environment with SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.27"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Support ESXi9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support ESXi9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support ESXi9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.27"}],"SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"114f2e8b6d9e4deea39e74ff427c00e2"}]},{"ProductId":"d93273aa12774694887dc3aab21ae996","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプター用のドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.10.0</li><li>qedrntv version 3.71.80.0</li><li>qedentv version 3.71.80.0</li><li>qedi version 2.74.10.0</li></ul><p><strong>Known issue</strong>: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solution in next driver release.</p>"},{"Lang":"ja","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.10.0</li><li>qedrntv version 3.71.80.0</li><li>qedentv version 3.71.80.0</li><li>qedi version 2.74.10.0</li></ul><p><strong>Known issue</strong>: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solution in next driver release.</p>"},{"Lang":"cn","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.10.0</li><li>qedrntv version 3.71.80.0</li><li>qedentv version 3.71.80.0</li><li>qedi version 2.74.10.0</li></ul><p><strong>Known issue</strong>: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solution in next driver release.</p>"}],"Files":[{"Bytes":"5830297","DateModified":"2025-07-16T08:40:55","FileList":["/cp067853.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedi/QLC_bootbank_qedi_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.80.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.80.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedf/QLC_bootbank_qedf_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedi-1100237886221730174.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedentv--5062932650923935948.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedrntv--1300904974122159212.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedf--7068176324000061616.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"7b8c66115bee7861e773fe46cb5280d7","Name":"cp067853.zip","Release":"2025-07-16T08:40:39","Revision":"","SHA1Sum":"3c17eddd28a0c313b4c6fdd7b3e3dd1bef04f8ea","SHA256Sum":"1d1ea7fe78e5fac619251314d503bb34a1dd9acf63b5b3867910dabcf1130f7b","Size":"5MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a"],"TypeOfChange":"1","Version":"2025.09.00","VibList":[{"Name":"qedf","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.80.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.80.0-1OEM.800.1.0.20613240"},{"Name":"qedi","Version":"2.74.10.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002bd","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-809015900220","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021d","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021f","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-16T03:57:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes a PSOD issue which is caused by the memory leak.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、メモリリークによって発生するPSODの問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes a PSOD issue which is caused by the memory leak.</p>","Lang":"cn"}],"Version":"2025.03.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.09.00"}],"SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.410.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedf:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.80.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.80.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedi:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fb37b7e36bfb498092b85a8f201267a6"}]},{"ProductId":"d026cab87ecf46f4a70676c4643d63f0","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFPおよびVK007680KWWFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5462856","DateModified":"2025-11-15T17:47:15","FileList":["cp068625.xml","cpqsetup.exe","KPE60X1GHPK4.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"2a9b54d83416fb5c2f3a825503703f7a","Name":"cp068625.exe","Release":"2025-11-15T17:41:05","Revision":"B","SHA1Sum":"0bcbcd48753624ff53a395a5d159853e30363e3e","SHA256Sum":"4695f7465eec97b497cd6c7b1f01749178ac5829a5b6faeffb87c7590b3dc111","Size":"5MB","TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows（x64）- MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK007680KWWFQ","TargetGUID":"562340a5-304b-3730-3638-304b57574651","Type":"nvme"},{"Id":"MK006400KWWFK","TargetGUID":"4d2340a5-304b-3630-3430-304b5757464b","Type":"nvme"},{"Id":"VK003840KWWFP","TargetGUID":"562340a5-304b-3330-3834-304b57574650","Type":"nvme"},{"Id":"MK003200KWWFH","TargetGUID":"4d2340a5-304b-3330-3230-304b57574648","Type":"nvme"},{"Id":"VK001920KWWFN","TargetGUID":"562340a5-304b-3130-3932-304b5757464e","Type":"nvme"},{"Id":"MK001600KWWFF","TargetGUID":"4d2340a5-304b-3130-3630-304b57574646","Type":"nvme"},{"Id":"VK000960KWWFL","TargetGUID":"562340a5-304b-3030-3936-304b5757464c","Type":"nvme"},{"Id":"MK00800KWWFE","TargetGUID":"002340a5-4b4d-3030-3830-304b57574645","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T07:31:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>これは、FW防御アルゴリズムのコード修正、アサート後のSN変更、およびPOSCAP誤警報を含むメンテナンスリリースです。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"cn"}],"Version":"HPK4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>.</li></ul>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"292d8b1e06bf4f8796fc78a8edb69243"}]},{"ProductId":"ddc8bdca3abc4ab8823e820be1ed4dfd","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"Lang":"ja","Value":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10およびGen11コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされるバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と機能強化を入手するため、インストールする必要があります。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"110909","DateModified":"2025-12-05T02:52:22","FileList":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"MD5Sum":"401b81757228bbe9ce4986a0765d5241","Name":"smartpqi-kmp-default-2.1.38-022.sles15sp7.x86_64.rpm","Release":"2025-12-05T02:41:09","Revision":"","SHA1Sum":"86dd54361801e484cf7e06270fbc1b4a9cf34572","SHA256Sum":"9712041892d1df9d69f5d055849569ed0534876d0ea2e53b4dbba3b401c951c7","Size":"108KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.38-022"},{"Bytes":"110926","DateModified":"2025-12-05T02:45:34","FileList":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"MD5Sum":"076211ffe8c86304e5e921e9a51478d3","Name":"smartpqi-kmp-default-2.1.38-022.sles15sp6.x86_64.rpm","Release":"2025-12-05T02:41:09","Revision":"","SHA1Sum":"ec15dbbb7b4b97f08c61c3affd70a19e4bc6f787","SHA256Sum":"e14f72911e21576369b59066e6570ce6fa1a0f4182c1a5346c155cb2ff22f5cc","Size":"108KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.38-022"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp;--oldpackage --replacefiles --replacepkgs smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;. If Installation attempted is failed with &ldquo;Failed Dependency&rdquo; Error below Arguments are used to re-try the Installation.</p><ul><li># rpm&nbsp;-Uvh --oldpackage --reinstall&nbsp;smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p>&nbsp;</p><p>Setup is now complete. Please REBOOT your computer NOW!!</p><p>&nbsp;</p><p>&nbsp;</p><p><strong>For SLES15 installations that will be using the Xen Hypervisor, run the following command after&nbsp;installing the driver rpm. This will ensure the updated driver is used for Xen.</strong></p><ul><li>/sbin/update-bootloader --refresh</li></ul><p>&nbsp;</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>システム管理者 (root) としてログインし、RPMを<br />ご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p><p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p><p> </p><ul><li># rpm -Uvh --oldpackage --replacefiles --replacepkgs smartpqi-kmp-default-<version>.sles15<OSupdate>.x86_64.rpm  </li></ul><p>         試行したインストールが\"Failed Dependency\"エラーで失敗した場合、インストールの再試行には次の引数を使用します。</p><ul><li># rpm -Uvh --oldpackage --reinstall smartpqi-kmp-default-<version>.sles15<OSupdate>.x86_64.rpm</li></ul><p> </p><p>Setup is now complete. Please REBOOT your computer NOW!!</p><p> </p><p> </p><p><strong>Xen Hypervisorを使用するSLES15インストールの場合は、ドライバーrpmをインストールした後、次のコマンドを実行します。これにより、アップデートされたドライバーがXenに使用されるようになります。</strong></p><ul><li>/sbin/update-bootloader --refresh</li></ul><p> </p><p><strong>注記</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p><ul><li># rpm -e smartpqi-kmp-default-<version>.sles15<OSupdate>.x86_64.rpm</li></ul><p><strong><u>エンタープライズサポート</u></strong><br />Smartアレイコントローラーのサポートに関しては <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p><p> </p><p> </p>"},{"Lang":"cn","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp;--oldpackage --replacefiles --replacepkgs smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;. If Installation attempted is failed with &ldquo;Failed Dependency&rdquo; Error below Arguments are used to re-try the Installation.</p><ul><li># rpm&nbsp;-Uvh --oldpackage --reinstall&nbsp;smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p>&nbsp;</p><p>Setup is now complete. Please REBOOT your computer NOW!!</p><p>&nbsp;</p><p>&nbsp;</p><p><strong>For SLES15 installations that will be using the Xen Hypervisor, run the following command after&nbsp;installing the driver rpm. This will ensure the updated driver is used for Xen.</strong></p><ul><li>/sbin/update-bootloader --refresh</li></ul><p>&nbsp;</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)"},{"Lang":"ja","Value":"HPE ProLiant Gen10、Gen10PlusおよびGen11 Smartアレイコントローラー (64ビット) ドライバーfor SUSE LINUX Enterprise Server 15 (64ビット)"},{"Lang":"cn","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T09:30:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added a timeout value to RAID path requests to physical devices.</li></ul>","Fixes":"<ul><li>Fixed an issue where the kernel call trace when calling smp_processor_id() in real-time kernel.&nbsp;</li><li>Fixed an issue of accessing NULL SCSI device pointer caused by a rare race condition.&nbsp;</li><li>Fixed a system crash issue caused by a divide-by-zero condition.&nbsp;</li><li>Fixed an issue where after a device has been removed, it&#39;s possible for a previously scheduled work item for a LUN reset to be executed.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added a timeout value to RAID path requests to physical devices.</li></ul>","Fixes":"<ul><li>リアルタイムカーネルでsmp_processor_id()を呼び出すときにカーネル呼び出しトレースが実行される問題を修正しました。 </li><li>まれな競合状態によって発生するNULL SCSIデバイスポインターへのアクセスの問題を修正しました。 </li><li>ゼロ除算条件によって発生するシステムクラッシュの問題を修正しました。 </li><li>デバイスが削除された後、以前にスケジュールされた LUNリセットの作業項目が実行される可能性がある問題を修正しました。 </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added a timeout value to RAID path requests to physical devices.</li></ul>","Fixes":"<ul><li>Fixed an issue where the kernel call trace when calling smp_processor_id() in real-time kernel.&nbsp;</li><li>Fixed an issue of accessing NULL SCSI device pointer caused by a rare race condition.&nbsp;</li><li>Fixed a system crash issue caused by a divide-by-zero condition.&nbsp;</li><li>Fixed an issue where after a device has been removed, it&#39;s possible for a previously scheduled work item for a LUN reset to be executed.&nbsp;</li></ul>","Lang":"cn"}],"Version":"2.1.36-026"},{"ReleaseNotes":[{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2.1.38-022"}],"SWKeys":[{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fa241aa0a39b4f01acb7dcad24b81808"}]},{"ProductId":"8a5f6b85a2a94dc58e5d42c516c7060a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB016000JWXKH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB016000JWXKH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JWXKH&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JWXKH&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19575513","DateModified":"2025-03-07T11:16:21","FileList":["/CP065940_BUILD_3.data","/CP065940.vmexe64","/CP065940.vmfile","/CP065940_VMw.zip","/CP065940.xml","/payload.json","/CP065940_VMw.zip/index.xml","/CP065940_VMw.zip/vendor-index.xml","/CP065940_VMw.zip/metadata.zip","/CP065940_VMw.zip/vib20/CP065940/HPE_bootbank_CP065940_HPDC.3-1OEM.800.1.0.20613240.vib","/CP065940_VMw.zip/metadata.zip/vendor-index.xml","/CP065940_VMw.zip/metadata.zip/vmware.xml","/CP065940_VMw.zip/metadata.zip/vibs/CP065940--2021015516232520248.xml","/CP065940_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065940_HPDC.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"063470b35ee44544ac2fc3ba3bc106a2","Name":"CP065940.zip","Release":"2025-03-07T11:15:37","Revision":"B","SHA1Sum":"5e3bcc2aa981a662f7ad4e5075d2f0c27588823c","SHA256Sum":"2136bfdb97680cbe69b0a2e08c5c01abd9f3acc2e092adcc9336638fede601e2","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC","VibList":[{"Name":"CP065940","Version":"HPDC.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JWXKH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB016000JWXKHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB016000JWXKH","TargetGUID":"4d2340a5-3042-3631-3030-304a57584b48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:13:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。</li><li>このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPDC"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDC"}],"SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6b0b91b47e2f4d9189480894f7b1ba61"}]},{"ProductId":"fcf6b49416e1460393e2103c04483878","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware release provides additional protection against command timeouts.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware release provides additional protection against command timeouts.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"5159981","DateModified":"2025-09-17T12:54:08","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/CP068857.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/TAMG06scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068857.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068857.scexe"],"MD5Sum":"ffba5522bab78fe4c8650beb5e88502a","Name":"firmware-hdd-faf39e0ff7-HPD9-10.1.x86_64.rpm","Release":"2025-09-17T17:43:05","Revision":"J","SHA1Sum":"14895babd87a1d3beeb4903dad329d8ba7c64aa7","SHA256Sum":"9568457a6d9c1c2bc2bf74ca65f0ad62bafa269e08a1f5cbaa296c074e2f65cf","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000JWJRQおよびMB006000JWJRPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000JWJRQ","TargetGUID":"4d2340a5-3042-3830-3030-304a574a5251","Type":"sas"},{"Id":"MB006000JWJRP","TargetGUID":"4d2340a5-3042-3630-3030-304a574a5250","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:58:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"026217c0626d4029b3c39b733ef408bc"}]},{"ProductId":"a6c377914cad4568810f0a24fc0faa52","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"26882820","DateModified":"2025-03-06T08:43:09","FileList":["/CP065978_BUILD_6.data","/CP065978.vmexe64","/CP065978.vmfile","/CP065978_VMw.zip","/CP065978.xml","/payload.json","/CP065978_VMw.zip/index.xml","/CP065978_VMw.zip/vendor-index.xml","/CP065978_VMw.zip/metadata.zip","/CP065978_VMw.zip/vib20/CP065978/HPE_bootbank_CP065978_HPG3.6-1OEM.800.1.0.20613240.vib","/CP065978_VMw.zip/metadata.zip/vendor-index.xml","/CP065978_VMw.zip/metadata.zip/vmware.xml","/CP065978_VMw.zip/metadata.zip/vibs/CP065978-6737174474719407004.xml","/CP065978_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065978_HPG3.6-1OEM.800.1.0.20613240.xml"],"MD5Sum":"ebdefb9ff926f12ec38050e85c165f3d","Name":"CP065978.zip","Release":"2025-03-06T08:42:23","Revision":"C","SHA1Sum":"574df1184a8b9e8b5571bb54506c68ba5ff73a02","SHA256Sum":"d9fce4e1bcb13e29f8558436bd33af5ae670cf25cf58f9907a53eb226864f977","Size":"25MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP065978","Version":"HPG3.6-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043281.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=service%20pack%20for%20proliant%20spp&amp;t=DriversandSoftware&amp;sort=relevancy&amp;numberOfResults=25\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=service%20pack%20for%20proliant%20spp&amp;t=DriversandSoftware&amp;sort=relevancy&amp;numberOfResults=25\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MK000480GWXFF、MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MK003840GWXFL","TargetGUID":"4d2340a5-304b-3330-3834-30475758464c","Type":"sata"},{"Id":"MK001920GWXFK","TargetGUID":"4d2340a5-304b-3130-3932-30475758464b","Type":"sata"},{"Id":"MK000960GWXFH","TargetGUID":"4d2340a5-304b-3030-3936-304757584648","Type":"sata"},{"Id":"MK000480GWXFF","TargetGUID":"4d2340a5-304b-3030-3438-304757584646","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:15:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"828713c2b35a4640b56377bf5971b97b"}]},{"ProductId":"e9b531c475a54ce6b287402b5c425933","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp067924.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2186285","DateModified":"2025-08-21T21:47:31","FileList":["./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/CP068492.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/cp067924.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/cp067924.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068492.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068492.scexe"],"MD5Sum":"4aa423de37b312aa19fed25f946bcce9","Name":"firmware-dl20ml30gen10sps-05.01.05.103-2.1.x86_64.rpm","Release":"2025-08-22T02:40:13","Revision":"B","SHA1Sum":"b851b5934bb34e86357ea15659333b5899615bb3","SHA256Sum":"3e95a6073fa23d452511f89ab6b9d1cc9b75f37f7f04d3fe4c27ecfd4a0b5436","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20/ML30 Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-09-22T02:39:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"05.01.05.103"},{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"05.01.05.103"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4b840130fd674097a45e2ff3ef245086"}]},{"ProductId":"eacabd6c758c41759c1c132130d3f614","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>HPK3</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong>.</p><ul style=\"list-style-type:square\"><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>HPK3</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong>.</p><ul style=\"list-style-type:square\"><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"22562137","DateModified":"2025-03-06T10:07:31","FileList":["/CP065979_BUILD_11.data","/CP065979.vmexe64","/CP065979.vmfile","/CP065979_VMw.zip","/CP065979.xml","/payload.json","/CP065979_VMw.zip/index.xml","/CP065979_VMw.zip/vendor-index.xml","/CP065979_VMw.zip/metadata.zip","/CP065979_VMw.zip/vib20/CP065979/HPE_bootbank_CP065979_HPK5.11-8.0.0.20613240.vib","/CP065979_VMw.zip/metadata.zip/vendor-index.xml","/CP065979_VMw.zip/metadata.zip/vmware.xml","/CP065979_VMw.zip/metadata.zip/vibs/CP065979--8238576472117587209.xml","/CP065979_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065979_HPK5.11-8.0.0.20613240.xml"],"MD5Sum":"cf549f0dbf08fb4faa38bb497add9796","Name":"CP065979.zip","Release":"2025-03-06T10:06:47","Revision":"E","SHA1Sum":"219dd47c2843f0484bdfe6dac752aaefbb1d8f9d","SHA256Sum":"8007b07a290fbc0f1a2b999cef4e4af9de20cd030577b59dd8e88850fde17bc3","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5","VibList":[{"Name":"CP065979","Version":"HPK5.11-8.0.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO000960KXAVL","TargetGUID":"562340a5-304f-3030-3936-304b5841564c","Type":"nvme"},{"Id":"MO000800KXAVN","TargetGUID":"4d2340a5-304f-3030-3830-304b5841564e","Type":"nvme"},{"Id":"MO001600KXAVT","TargetGUID":"4d2340a5-304f-3130-3630-304b58415654","Type":"nvme"},{"Id":"MO003200KXAVU","TargetGUID":"4d2340a5-304f-3330-3230-304b58415655","Type":"nvme"},{"Id":"MO006400KXAVV","TargetGUID":"4d2340a5-304f-3630-3430-304b58415656","Type":"nvme"},{"Id":"VO003840KXAVQ","TargetGUID":"562340a5-304f-3330-3834-304b58415651","Type":"nvme"},{"Id":"VO007680KXAVR","TargetGUID":"562340a5-304f-3730-3638-304b58415652","Type":"nvme"},{"Id":"VO001920KXAVP","TargetGUID":"562340a5-304f-3130-3932-304b58415650","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:15:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPK5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK5"}],"SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"81a0178ad61c4266ba2c2e5a85a13a6a"}]},{"ProductId":"4a6cd8bdbba64726bce1bd7c81b875da","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5519439","DateModified":"2025-11-11T09:16:03","FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-qla2xxx","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"MD5Sum":"cd5fc12a941b86206702fb13dada6fed","Name":"kmod-qlgc-qla2xxx-10.02.15.00_k1-1.rhel10u0.x86_64.rpm","Release":"2025-11-11T09:10:05","Revision":"","SHA1Sum":"b778bec33afa09de319b4c1012f0a47d7b62544d","SHA256Sum":"a133f4220eec7acaa6645371652991aa45ed068a963b5b8d383d5b27625d4bb3","Size":"5MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.15.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel10u0.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel10u0.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel10u0.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 10 Update 0 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 10 Update 0 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 10 Update 0 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T08:19:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.15.00-k1"}],"SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ec0dd59b68c94940804f8e3ae0c08dc6"}]},{"ProductId":"3d004333c656491289fdf09d5881fcdd","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFPおよびVK007680KWWFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>.</li></ul><p>&nbsp;<strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>.</li></ul><p>&nbsp;<strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"7389029","DateModified":"2025-09-21T19:53:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/CP068906.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/KPE60X1GHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068906.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068906.scexe"],"MD5Sum":"e1e752874a67973b2f3fce207895433a","Name":"firmware-hdd-54addf5312-HPK4-3.1.x86_64.rpm","Release":"2025-09-22T00:42:15","Revision":"C","SHA1Sum":"fbb983282fb7826e440b017a2ade3149f0cb330a","SHA256Sum":"a2d0a41d8933e4bfc6c4effa8dd15dac4c49700f837e4caf2da9cfdc2da7f7c8","Size":"7MB","TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4"}],"Installation":{"Command":"CP041698.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p><p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p><p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux（x64）- MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK007680KWWFQ","TargetGUID":"562340a5-304b-3730-3638-304b57574651","Type":"nvme"},{"Id":"MK006400KWWFK","TargetGUID":"4d2340a5-304b-3630-3430-304b5757464b","Type":"nvme"},{"Id":"VK003840KWWFP","TargetGUID":"562340a5-304b-3330-3834-304b57574650","Type":"nvme"},{"Id":"MK003200KWWFH","TargetGUID":"4d2340a5-304b-3330-3230-304b57574648","Type":"nvme"},{"Id":"VK001920KWWFN","TargetGUID":"562340a5-304b-3130-3932-304b5757464e","Type":"nvme"},{"Id":"MK001600KWWFF","TargetGUID":"4d2340a5-304b-3130-3630-304b57574646","Type":"nvme"},{"Id":"VK000960KWWFL","TargetGUID":"562340a5-304b-3030-3936-304b5757464c","Type":"nvme"},{"Id":"MK00800KWWFE","TargetGUID":"002340a5-4b4d-3030-3830-304b57574645","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:45:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>これは、FW防御アルゴリズムのコード修正、アサート後のSN変更、およびPOSCAP誤警報を含むメンテナンスリリースです。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"cn"}],"Version":"HPK4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>これは、FW防御アルゴリズムのコード修正、アサート後のSN変更、およびPOSCAP誤警報を含むメンテナンスリリースです。</li><li>詳しくは、HPEカスタマーアドバイザリ: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us\" id=\"menurh8t\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00150197en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00150197en_us</a>.</li></ul>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7ebf0ab82df74654bb70a9bc314fc227"}]},{"ProductId":"0a50ffd5675c4918bbc84041f4e69741","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Ubuntu&nbsp;Linux&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Ubuntu&nbsp;Linux&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4233424","DateModified":"2025-08-03T01:08:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-1.1/CP067330.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-1.1/HPG1_PM897.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067330.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067330.scexe"],"MD5Sum":"f93de83d6f11ecacb17b815c4c4d5746","Name":"firmware-hdd-9475583fb5_0HPG1-1.1_amd64.deb","Release":"2025-08-03T06:02:05","Revision":"","SHA1Sum":"f93be62cba7fab4542b7bfaf6ecd35d53e7a9340","SHA256Sum":"d6085726f16f907b6c1343e608a8e2f6655163e4c9b66572d931496cac3044a2","Size":"4MB","TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040346.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MK000480GZXRA","TargetGUID":"4d2340a5-304b-3030-3438-30475a585241","Type":"sata"},{"Id":"MK001920GZXRC","TargetGUID":"4d2340a5-304b-3130-3932-30475a585243","Type":"sata"},{"Id":"MK000960GZXRB","TargetGUID":"4d2340a5-304b-3030-3936-30475a585242","Type":"sata"},{"Id":"MK003840GZXRV","TargetGUID":"4d2340a5-304b-3330-3834-30475a585256","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:50:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1124183949ec436b815799252e731e83"}]},{"ProductId":"fc2945bc3e5744fea9d120a012546560","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA Drive"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000GWUDAドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG2</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG2</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6536026","DateModified":"2025-09-17T11:31:05","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/CP068848.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/WLEBsssATFG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068848.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068848.scexe"],"MD5Sum":"7f96a425114a32220621812da1eac5d1","Name":"firmware-hdd-41cdb1c9da-HPG3-5.1.x86_64.rpm","Release":"2025-09-17T16:20:05","Revision":"E","SHA1Sum":"8a1e2dcabe269dc301216be9324894bbe27f4279","SHA256Sum":"ec0826bea4e3419cb64cbd652f0985a5ef997549e0ffc8210c5b12a007011182","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP041508.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWUDA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000GWUDAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000GWUDA","TargetGUID":"4d2340a5-3042-3431-3030-304757554441","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:19:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RHEL 10のサポートを追加しました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"26783d282a644af9b665b990904dd324"}]},{"ProductId":"f5aa8733027b4498a80cd2e690d91986","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.62 (01/09/2026)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11610869","DateModified":"2026-01-13T21:36:18","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.62_2026_01_09-1.1/CP070216.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.62_2026_01_09-1.1/U31_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070216.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070216.scexe"],"MD5Sum":"d9ef3ffa5b534c0bc3763258cf2df6dc","Name":"firmware-system-u31-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-14T03:27:17","Revision":"","SHA1Sum":"84596fbb2eff690a675cea6258deba93ce4fc90c","SHA256Sum":"d621fc6e32cfd6d3e429e22446ed5570c5310e37b6c9463648063fb7adf10fe7","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10（U31）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T02:34:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ec291f98ff8749b2a16d2601fc7723bd"}]},{"ProductId":"f22e031456d1410688940c3efe38cf1d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.72 (01/09/2026)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.72 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9073976","DateModified":"2026-01-14T02:21:19","FileList":["cp070231.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U48_3.72_01_09_2026.signed.flash"],"MD5Sum":"822702821a1814ad5c821108ee31dc50","Name":"cp070231.exe","Release":"2026-01-14T02:19:07","Revision":"","SHA1Sum":"b396488bda540c487624c84bf3f6aece78f7fe4e","SHA256Sum":"2cf81f7792b9e2772832d20ed69544fd2b94c635ba62e8e16c39a146684d1a15","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"TypeOfChange":"1","Version":"3.72_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:44:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.103と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.70_08-08-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_01-09-2026"}],"SWKeys":[{"Name":"U48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"94df683fa8b644c6a9273f8868761e88"}]},{"ProductId":"8aa4f1e30dfc4417885cea85b551314e","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_317.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.17"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_317.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.17"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_317.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.17"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides updated iLO firmware that can be installed directly on supported Linux Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the Smart Update Manager."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるLinuxオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、Smart Update Managerと一緒に使用することができます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"}],"Files":[{"Bytes":"34095212","DateModified":"2025-12-03T01:47:13","FileList":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1/CP069141.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1/ilo5_317.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.17-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069141.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069141.scexe"],"MD5Sum":"86fe35958d819142da1d90cff0eadc96","Name":"firmware-ilo5-3.17-1.1.x86_64.rpm","Release":"2025-12-03T07:36:58","Revision":"","SHA1Sum":"c88c2d81568dd8aa4fd3675896a521fc186532ea","SHA256Sum":"e6cb1c21348ff4b99e551903c2fc5d15153cf2ab6a2b02c8a4e1b2d23f253425","Size":"32MB","TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.17"}],"Installation":{"Command":"sh CP0XXXXX.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Below are the steps to install/upgrade Linux Smart Component rpm files</strong></p><p style=\"margin-left:40px\">Extract the rpm file using the command &lsquo;rpm2cpio &lt;filename&gt; | cpio &ndash;idmv&rsquo;<br />Navigate to /usr/lib/x86_64-linux-gnu/firmware-ilo5-ri11-1.40-1.1<br />Run the &lsquo;hpsetup&rsquo; file using the command ./hpsetup or ./hpsetup &ndash;f when updating to same version</p><p style=\"margin-left:40px\">&nbsp;</p><p><strong>To install the Linux Smart Components perform the below steps</strong></p><p style=\"margin-left:40px\">Extract the RPM file and navigate to /usr/lib/x86_64-linux-gnu.<br />To use the Set up file, navigate to firmware-ilo5-2.xx-1.1 folder and run the same.<br />To use .scexe files, navigate to hp-scexe-compat or scexe-compat folders and run the same.</p>"},{"Lang":"ja","Value":"<p><strong>Below are the steps to install/upgrade Linux Smart Component rpm files</strong></p><p style=\"margin-left:40px\">Extract the rpm file using the command &lsquo;rpm2cpio &lt;filename&gt; | cpio &ndash;idmv&rsquo;<br />Navigate to /usr/lib/x86_64-linux-gnu/firmware-ilo5-ri11-1.40-1.1<br />Run the &lsquo;hpsetup&rsquo; file using the command ./hpsetup or ./hpsetup &ndash;f when updating to same version</p><p style=\"margin-left:40px\">&nbsp;</p><p><strong>To install the Linux Smart Components perform the below steps</strong></p><p style=\"margin-left:40px\">Extract the RPM file and navigate to /usr/lib/x86_64-linux-gnu.<br />To use the Set up file, navigate to firmware-ilo5-2.xx-1.1 folder and run the same.<br />To use .scexe files, navigate to hp-scexe-compat or scexe-compat folders and run the same.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5120"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-09T08:47:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>There are no enhancements in the current HPE iLO 5 v3.16 release.</p>","Fixes":"<p>&bull; Fixed an issue with the backup_start event to protect the back up process from auxiliary power cycle interruptions. This fix includes the implementation of IML logging.<br />&bull; Fixed an issue with HPE iLO to display power supplies as per power supply type AC or DC.<br />&bull;&nbsp;Fixed an issue where iLO could report the network status as &ldquo;Unknown&rdquo; instead of &ldquo;OK&rdquo; on Raider platforms.</p>","Lang":"en"},{"Enhancements":"<p>現在のHPE iLO 5 v3.16リリースには機能強化はありません。</p>","Fixes":"<p>• 補助電源サイクルの中断からバックアップ プロセスを保護するためのbackup_startイベントの問題を修正しました。この修正には、IMLログの実装が含まれています。<br />• HPE iLOで電源装置を電源タイプACまたはDCに応じて表示する問題を修正しました。<br />• Raider プラットフォームでiLOがネットワークステータスを「OK」ではなく「不明」と報告する問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"<p>There are no enhancements in the current HPE iLO 5 v3.16 release.</p>","Fixes":"<p>&bull; Fixed an issue with the backup_start event to protect the back up process from auxiliary power cycle interruptions. This fix includes the implementation of IML logging.<br />&bull; Fixed an issue with HPE iLO to display power supplies as per power supply type AC or DC.<br />&bull;&nbsp;Fixed an issue where iLO could report the network status as &ldquo;Unknown&rdquo; instead of &ldquo;OK&rdquo; on Raider platforms.</p>","Lang":"cn"}],"Version":"3.16"},{"ReleaseNotes":[{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"en"},{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"ja"},{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"cn"}],"Version":"3.17"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"28ca4bc4cf0b4a139c2e833b8a3b3822"}]},{"ProductId":"b61013381e514e74835819b0f29c6165","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB012000JZYVN、MB014000JZYVP、MB016000JZYVQ、MB018000JYCLK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4175032","DateModified":"2025-11-14T11:36:14","FileList":["cp068765.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG09scHPD4.rel"],"MD5Sum":"4f1cb72d68145ee888fc07af7aefeba4","Name":"cp068765.exe","Release":"2025-11-14T11:31:30","Revision":"D","SHA1Sum":"3b2cdae9ddd323b6a4b0cca2a424ec11a2928b83","SHA256Sum":"9c8d30a6958d328c8b261ce2e0365bfb04783417b08fb23562a43e3d028fba60","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQおよびMB018000JYCLKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB012000JZYVN","TargetGUID":"4d2340a5-3042-3231-3030-304a5a59564e","Type":"sas"},{"Id":"MB014000JZYVP","TargetGUID":"4d2340a5-3042-3431-3030-304a5a595650","Type":"sas"},{"Id":"MB016000JZYVQ","TargetGUID":"4d2340a5-3042-3631-3030-304a5a595651","Type":"sas"},{"Id":"MB018000JYCLK","TargetGUID":"4d2340a5-3042-3831-3030-304a59434c4b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T09:48:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bf7bdb27b83840859208ee6943062446"}]},{"ProductId":"b57ffa2f7fe942a89e589fe3043c5ffa","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the HPE 12Gb/s SAS Expander "},{"Lang":"cn","Value":"This Smart Component provides firmware for the HPE 12Gb/s SAS Expander "},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE 12Gb/s SASエキスパンダーのファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3626568","DateModified":"2025-11-14T02:04:12","FileList":["cp067916.xml","cpqsetup.exe","firmware-Signed-5.15-build-000.bin.fw","payload.json","setup.dll"],"MD5Sum":"0ce1a92462507b12c22c71caf021dd8f","Name":"cp067916.exe","Release":"2025-11-14T01:54:05","Revision":"E","SHA1Sum":"ab45da455fc8605979d9faef8470b42d9b6f2246","SHA256Sum":"5bd3d79c3cf13c93a02403ea31857860080def96250cf967ba9e04b9050e8471","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\" style=\"color:#0563c1; text-decoration:underline\">Service Pack for ProLiant&nbsp;</a>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\" style=\"color:#0563c1; text-decoration:underline\">Service Pack for ProLiant&nbsp;</a>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\" style=\"color:#0563c1; text-decoration:underline\">Service Pack for ProLiant</a></strong>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"cn","Value":"面向 Windows (x64) 的在线 ROM 刷新组件 – 适用于 HPE 智能阵列控制器和 HPE HBA 控制器的 HPE 12Gb/s SAS 扩展器固件"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE 12Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-23T06:23:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Azure Stack HCI 23H2のサポートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"cn"}],"Version":"5.15"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.15"}],"SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9ec7574dfdf54b5b857e9c488e3c06aa"}]},{"ProductId":"8384f9a8878649da8d668b07fb30c48e","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_317.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.17"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_317.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.17"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_317.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.17"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides and installs an updated version of firmware for the iLO 5 Management Processor allowing for continued management support of your Server."},{"Lang":"ja","Value":"このコンポーネントは、iLO 5マネジメントプロセッサーがご使用のサーバーを継続して管理サポートできるようアップデートされたバージョンのファームウェアを提供しインストールします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"}],"Files":[{"Bytes":"34264040","DateModified":"2025-12-03T08:17:46","FileList":["cp069142.xml","cpqsetup.exe","ilo5_317.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"MD5Sum":"a52d92e0ce4b3004a043060193ae2cd1","Name":"cp069142.exe","Release":"2025-12-03T08:15:21","Revision":"","SHA1Sum":"cc916b2236109342760be81af4469ef68a77f97b","SHA256Sum":"42580a2dcd8c86206601339ba9ff2fb933c172000d729553c9220deb07ba2d5b","Size":"32MB","TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.17"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Install the firmware using one of these options:</strong></p><ul><li>Run the Component on the host to be updated.<br />The component will update the iLO 5&nbsp;firmware and reset the iLO 5&nbsp;processor.<br />&nbsp;</li><li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO5_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:<ul><li>Login to iLO 5, navigate to the Update Firmware page, and update the firmware from there.</li><li>Use the HPE Lights-Out Configuration Utility, CPQLOCFG, and RIBCL/XML scripts to update iLO 5&nbsp;across the network.</li><li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO 5&nbsp;from the supported host OS.</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>Install the firmware using one of these options:</strong></p><ul><li>Run the Component on the host to be updated.<br />The component will update the iLO 5&nbsp;firmware and reset the iLO 5&nbsp;processor.<br />&nbsp;</li><li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO5_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:<ul><li>Login to iLO 5, navigate to the Update Firmware page, and update the firmware from there.</li><li>Use the HPE Lights-Out Configuration Utility, CPQLOCFG, and RIBCL/XML scripts to update iLO 5&nbsp;across the network.</li><li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO 5&nbsp;from the supported host OS.</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64- HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5120"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"1","Name":"Microsoft Windows 7 (64-bit) - All Editions","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows 8.1 (64-bit)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-09T08:47:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>There are no enhancements in the current HPE iLO 5 v3.16 release.</p>","Fixes":"<p>&bull; Fixed an issue with the backup_start event to protect the back up process from auxiliary power cycle interruptions. This fix includes the implementation of IML logging.<br />&bull; Fixed an issue with HPE iLO to display power supplies as per power supply type AC or DC.<br />&bull;&nbsp;Fixed an issue where iLO could report the network status as &ldquo;Unknown&rdquo; instead of &ldquo;OK&rdquo; on Raider platforms.</p>","Lang":"en"},{"Enhancements":"<p>現在のHPE iLO 5 v3.16リリースには機能強化はありません。</p>","Fixes":"<p>• 補助電源サイクルの中断からバックアップ プロセスを保護するためのbackup_startイベントの問題を修正しました。この修正には、IMLログの実装が含まれています。<br />• HPE iLOで電源装置を電源タイプACまたはDCに応じて表示する問題を修正しました。<br />• Raider プラットフォームでiLOがネットワークステータスを「OK」ではなく「不明」と報告する問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"<p>There are no enhancements in the current HPE iLO 5 v3.16 release.</p>","Fixes":"<p>&bull; Fixed an issue with the backup_start event to protect the back up process from auxiliary power cycle interruptions. This fix includes the implementation of IML logging.<br />&bull; Fixed an issue with HPE iLO to display power supplies as per power supply type AC or DC.<br />&bull;&nbsp;Fixed an issue where iLO could report the network status as &ldquo;Unknown&rdquo; instead of &ldquo;OK&rdquo; on Raider platforms.</p>","Lang":"cn"}],"Version":"3.16"},{"ReleaseNotes":[{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"en"},{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"ja"},{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"cn"}],"Version":"3.17"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"8167854a7ae74fc0a78e73884f6d9260"}]},{"ProductId":"3e44af8bcf3140b3bef280f7e913e5b4","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b58554a54","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b58554a55","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58554a56","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58554b41","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b58554a4e","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b58554a50","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b58554a51","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b58554a52","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3531-3336-304b59475a51","Version":"HPK2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR, VO015360KYGZQ"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR, VO015360KYGZQ"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR, VO015360KYGZQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2125020","DateModified":"2024-05-22T12:21:14","FileList":["Kioxia_CD8_KACD8ALSHPK2.HPb","Kioxia_CD8_KACD8ALSHPK2.xml","payload.json"],"MD5Sum":"4d77aed5c56943877c8dbb93f253f639","Name":"Kioxia_CD8_KACD8ALSHPK2.fwpkg","Release":"2024-05-22T12:17:16","Revision":"","SHA1Sum":"161d5e6c35207d4d2116a654b641a66199a9c95c","SHA256Sum":"05cfb76092d81ad7955109b6463156b6bc52fd93d868246de9d783f855aace5f","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304b58554a54","4d2340a5-304f-3130-3630-304b58554a55","4d2340a5-304f-3330-3230-304b58554a56","4d2340a5-304f-3630-3430-304b58554b41","562340a5-304f-3030-3936-304b58554a4e","562340a5-304f-3130-3932-304b58554a50","562340a5-304f-3330-3834-304b58554a51","562340a5-304f-3730-3638-304b58554a52","562340a5-304f-3531-3336-304b59475a51"],"TypeOfChange":"1","Version":"HPK2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR and VO015360KYGZQ"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR and VO015360KYGZQ"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR and VO015360KYGZQ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO000800KXUJT","TargetGUID":"4d2340a5-304f-3030-3830-304b58554a54","Type":"nvme"},{"Id":"MO001600KXUJU","TargetGUID":"4d2340a5-304f-3130-3630-304b58554a55","Type":"nvme"},{"Id":"MO003200KXUJV","TargetGUID":"4d2340a5-304f-3330-3230-304b58554a56","Type":"nvme"},{"Id":"MO006400KXUKA","TargetGUID":"4d2340a5-304f-3630-3430-304b58554b41","Type":"nvme"},{"Id":"VO000960KXUJN","TargetGUID":"562340a5-304f-3030-3936-304b58554a4e","Type":"nvme"},{"Id":"VO001920KXUJP","TargetGUID":"562340a5-304f-3130-3932-304b58554a50","Type":"nvme"},{"Id":"VO003840KXUJQ","TargetGUID":"562340a5-304f-3330-3834-304b58554a51","Type":"nvme"},{"Id":"VO007680KXUJR","TargetGUID":"562340a5-304f-3730-3638-304b58554a52","Type":"nvme"},{"Id":"VO015360KYGZQ","TargetGUID":"562340a5-304f-3531-3336-304b59475a51","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-06-22T11:34:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</li></ul>","Lang":"cn"}],"Version":"HPK2"}],"SWKeys":[{"Name":"MO000800KXUJT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXUJU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXUJV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXUKA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KXUJN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXUJP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXUJQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXUJR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYGZQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"38bbc6322f054a4b9d684698cc19c086"}]},{"ProductId":"b271ca95088c47b0b57cf56bd9562a4c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV&nbsp; Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV&nbsp; Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5959608","DateModified":"2025-09-21T21:53:59","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/CP068924.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/KAPM6ALFHPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068924.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068924.scexe"],"MD5Sum":"690ea854413271b21d8a15486bcdfd17","Name":"firmware-hdd-8f501d6cf1-HPD4-2.1.x86_64.rpm","Release":"2025-09-22T02:43:31","Revision":"B","SHA1Sum":"640c0e7e027bdc1c0daf4e7ecc77e1c4d443e386","SHA256Sum":"8ef4645dd66200255d41b97ab89a0b3d6e9cd02a618ba7134dafc9cb85237d05","Size":"5MB","TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP041670.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール (rpm -ivh)は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン:</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO003840XZCLT","TargetGUID":"562340a5-304f-3330-3834-30585a434c54","Type":"sas"},{"Id":"MO001600XZCLV","TargetGUID":"4d2340a5-304f-3130-3630-30585a434c56","Type":"sas"},{"Id":"MO000800XZCLQ","TargetGUID":"4d2340a5-304f-3030-3830-30585a434c51","Type":"sas"},{"Id":"VO007680XZCMB","TargetGUID":"562340a5-304f-3730-3638-30585a434d42","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:06:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a01b30d9ab32481babdfa599e5fca420"}]},{"ProductId":"d0bba068f7ca4e978bcc6d2bf9e8abf7","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSND3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3231-3030-304a5945534e","Version":"HPD3"},{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSND3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3631-3030-304a59455643","Version":"HPD3"},{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSND3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3032-3030-304a59455644","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model: MB12000JYESN, MB16000JYEVC and MB20000JYEVD"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB12000JYESN、MB16000JYEVC、MB20000JYEVD"},{"Lang":"cn","Value":"This package provides firmware for the following drive model: MB12000JYESN, MB16000JYEVC and MB20000JYEVD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Enhancements/New Features:</strong></p><ul><li>RPM data missing from iLO GUI</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Regular FW fix on assert, time-out, error log several fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Enhancements/New Features:</strong></p><ul><li>RPM data missing from iLO GUI</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Regular FW fix on assert, time-out, error log several fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Enhancements/New Features:</strong></p><ul><li>RPM data missing from iLO GUI</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Regular FW fix on assert, time-out, error log several fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3770075","DateModified":"2025-11-27T08:47:19","FileList":["payload.json","Seagate_Summit_SUMMITSUSND3.HPb","Seagate_Summit_SUMMITSUSND3.xml"],"MD5Sum":"32ec623e6c3162ffaf452939095ea565","Name":"Seagate_Summit_SUMMITSUSND3.fwpkg","Release":"2025-11-27T08:44:09","Revision":"B","SHA1Sum":"7f2b1192df02cde396e7efcb7c3674f0fddc652d","SHA256Sum":"1452e5d30ef9fa05e95baf7a678ccc8829560d560eea739188b9812298215723","Size":"3MB","TargetGUIDs":["002340a5-424d-3231-3030-304a5945534e","002340a5-424d-3631-3030-304a59455643","002340a5-424d-3032-3030-304a59455644"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB12000JYESN, MB16000JYEVC, MB20000JYEVD"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MB12000JYESN, MB16000JYEVC, MB20000JYEVD"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB12000JYESN, MB16000JYEVC, MB20000JYEVD"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB12000JYESN","TargetGUID":"002340a5-424d-3231-3030-304a5945534e","Type":"sas"},{"Id":"MB16000JYEVC","TargetGUID":"002340a5-424d-3631-3030-304a59455643","Type":"sas"},{"Id":"MB20000JYEVD","TargetGUID":"002340a5-424d-3032-3030-304a59455644","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-27T07:23:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>RPM data missing from iLO GUI</li></ul>","Fixes":"<ul><li>Regular FW fix on assert, time-out, error log several fixes</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>RPM data missing from iLO GUI</li></ul>","Fixes":"<ul><li>Regular FW fix on assert, time-out, error log several fixes</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>RPM data missing from iLO GUI</li></ul>","Fixes":"<ul><li>Regular FW fix on assert, time-out, error log several fixes</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB12000JYESN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB16000JYEVC","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB20000JYEVD","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"83ab6972351c42d3b0ce1fc4cf3585d6"}]},{"ProductId":"830142111c0e4cccaca01db3bc2edf65","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"},{"Lang":"cn","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problems Fixed:</strong></p><ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problems Fixed:</strong></p><ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problems Fixed:</strong></p><ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"}],"Files":[{"Bytes":"4030132","DateModified":"2025-07-31T11:40:26","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/85032G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/CP067323.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067323.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067323.scexe"],"MD5Sum":"bdf1dff7886c2814f25f5ea4c1ef2995","Name":"firmware-hdd-805abb7e9c_85032G00-1.1_amd64.deb","Release":"2025-07-31T16:31:45","Revision":"","SHA1Sum":"c6c2f8d40583fb44315482fcb437367132030d48","SHA256Sum":"4c008e3b2e23aca8941310b6efda30f7772ad1a5acce53166bfca6941f02fcf8","Size":"3MB","TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00"}],"Installation":{"Command":"CP042967.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VS003840KWXFQ","TargetGUID":"562340a5-3053-3330-3834-304b57584651","Type":"nvme"},{"Id":"VS001920KWXFP","TargetGUID":"562340a5-3053-3130-3932-304b57584650","Type":"nvme"},{"Id":"VS000960KWXFN","TargetGUID":"562340a5-3053-3030-3936-304b5758464e","Type":"nvme"},{"Id":"VS000480KXALB","TargetGUID":"562340a5-3053-3030-3438-304b58414c42","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:23:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul>","Lang":"cn"}],"Version":"85032G00"}],"SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"da602177dce24501861242b15aece4e1"}]},{"ProductId":"a294766010e4496a9a5cf2711f22fa84","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U47_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33601018","DateModified":"2026-01-12T08:00:11","FileList":["payload.json","U47_2.54_01_09_2026.signed.flash","U47_2.54_01_09_2026.xml"],"MD5Sum":"f8d8bd1a2ec71e05b4f6eacb54fe02ab","Name":"U47_2.54_01_09_2026.fwpkg","Release":"2026-01-12T07:57:00","Revision":"","SHA1Sum":"d6282fbecf129752d1dcd6bb4bd26904c2207fb6","SHA256Sum":"90d5e68a93e751c7867e4301b52434f54a5c0e819c5983a25c375fc020013c25","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant XL220n/XL290n Gen10 Plus 1Uノードおよび2Uノード受注構成サーバー（U47） "},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T07:39:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Whitley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.802（2.50_07_24_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"1a0cf8385cb643688cd23408da998bdb"}]},{"ProductId":"2ef4b1fccb0b4e4aa4c8281327ada522","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4890683","DateModified":"2025-11-11T08:47:43","FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"MD5Sum":"c49570527b4c7877d426cd3048bddc59","Name":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-11-11T08:40:03","Revision":"","SHA1Sum":"65d70d02ffa2a5b7b9b800b044ca00471ff27d14","SHA256Sum":"f9df5f079e046d566e30490dadee3593068216fe1953dac0b771a16faeecb8f0","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.15.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k5.3.18_57-2.sles15sp6.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k5.3.18_57-2.sles15sp6.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k5.3.18_57-2.sles15sp6.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"SuSE Linux Enterprise Server 15 Service Pack 6ファイバーチャネルドライバーキットfor HPE QLogicホストバスアダプター"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T08:52:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.15.00-k1"}],"SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"55f1d9ad1e864cc284e50f954f3d60e7"}]},{"ProductId":"1d54c8dcf99741aabe78b8a4e54d84f8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE "},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp;&nbsp;&nbsp;This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.&nbsp;</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp;&nbsp;&nbsp;This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.&nbsp;</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6208637","DateModified":"2025-09-21T22:10:01","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/CP068931.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068931.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068931.scexe"],"MD5Sum":"5cf655a53b2a51ba08aa0c34c6f4b943","Name":"firmware-hdd-10385ef3e6-HPD2-15.1.x86_64.rpm","Release":"2025-09-22T02:59:04","Revision":"O","SHA1Sum":"330bbaabe9ea4da638b0301a24cc757a34721257","SHA256Sum":"7d3e46811527af7da5b4e1d2ff79b78196b9fe5562ea3119ee25797af0bd25ef","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041452.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JWRTH","TargetGUID":"4d2340a5-3042-3431-3030-304a57525448","Type":"sas"},{"Id":"MB012000JWRTF","TargetGUID":"4d2340a5-3042-3231-3030-304a57525446","Type":"sas"},{"Id":"MB010000JWRTE","TargetGUID":"4d2340a5-3042-3031-3030-304a57525445","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:13:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.&nbsp;</li></ul>","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"27009a68f379417b83776e4d996a6ca0"}]},{"ProductId":"9adece559a5e4fcf8de67cd47aa7d7c7","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505a57534c","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30505a57534e","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30505a575350","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30505a584642","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-30505a584555","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。VO000960PZWSL、VO001920PZWSN、VO003840PZWSP、VO007680PZXFB、およびVO015360PZXEU"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>.</li></ul><p><strong>Known Issues:</strong></p><ul><li>FW cannot downgrade to HPD2.</li></ul>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付:</strong><br />     HPD4<br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPD3<br /><strong>以前のファームウェアバージョン：</strong><br />     HPD3<br /><strong>機能強化/新しい機能：</strong><br />     なし<br /><strong>修正された問題点：</strong></p><ul><li>これはファームウェアメンテナンスリリースです。その他のバグ修正と改善とともに、潜在的なデータロスの問題に対処します。</li><li>詳しくは、HPE顧客向け報告：<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>を参照してください。</li></ul><p><strong>既知の問題点：</strong></p><ul><li>FWはHPD2にダウングレードできません。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>.</li></ul><p><strong>Known Issues:</strong></p><ul><li>FW cannot downgrade to HPD2.</li></ul>"}],"Files":[{"Bytes":"1994747","DateModified":"2025-07-15T09:58:17","FileList":["payload.json","Samsung_PM165X_GPM1653SAMD4.HPb","Samsung_PM165X_GPM1653SAMD4.xml"],"MD5Sum":"e96e84497d0b345dda789e67ffe43e93","Name":"Samsung_PM165X_GPM1653SAMD4.fwpkg","Release":"2025-08-14T00:00:00","Revision":"","SHA1Sum":"3e486a890f623ff9eb2aa10cb1c42554675bd7a9","SHA256Sum":"35feb07648f869b17ebe0c4406d5c1d0aec7cf665a48250be9663162ddb20aeb","Size":"1MB","TargetGUIDs":["562340a5-304f-3030-3936-30505a57534c","562340a5-304f-3130-3932-30505a57534e","562340a5-304f-3330-3834-30505a575350","562340a5-304f-3730-3638-30505a584642","562340a5-304f-3531-3336-30505a584555"],"TypeOfChange":"2","Version":"HPD4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\" id=\"menurdf7\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\"> https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/</a> to search and download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager (SUM) を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 <a href=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\" id=\"menurdf7\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\">https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/</a>を参照して、iLOrestツールの最新バージョンを検索してダウンロードしてください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\" id=\"menurdf7\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\"> https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/</a> to search and download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - VO000960PZWSL、VO001920PZWSN、VO003840PZWSP、VO007680PZXFB、およびVO015360PZXEU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO000960PZWSL","TargetGUID":"562340a5-304f-3030-3936-30505a57534c","Type":"sas"},{"Id":"VO001920PZWSN","TargetGUID":"562340a5-304f-3130-3932-30505a57534e","Type":"sas"},{"Id":"VO003840PZWSP","TargetGUID":"562340a5-304f-3330-3834-30505a575350","Type":"sas"},{"Id":"VO007680PZXFB","TargetGUID":"562340a5-304f-3730-3638-30505a584642","Type":"sas"},{"Id":"VO015360PZXEU","TargetGUID":"562340a5-304f-3531-3336-30505a584555","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-21T07:07:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>&nbsp;which will be active on 18-Aug-2025.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>これはファームウェアメンテナンスリリースです。その他のバグ修正と改善とともに、潜在的なデータロスの問題に対処します。</li><li>詳しくは、HPE顧客向け報告：<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a> (2025年8月18日から有効) を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>&nbsp;which will be active on 18-Aug-2025.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>これはファームウェアメンテナンスリリースです。その他のバグ修正と改善とともに、潜在的なデータロスの問題に対処します。</li><li>詳しくは、HPE顧客向け報告：<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"VO000960PZWSL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920PZWSN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PZWSP","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PZXFB","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO015360PZXEU","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Critical"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"e4dd77efe5874d5182f4c9320fb8bada"}]},{"ProductId":"990fcc25e986467fbdc6e3aae2e41a2c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK7</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK7</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK7</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6289389","DateModified":"2025-09-21T21:41:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/CP068921.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/KACM6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068921.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068921.scexe"],"MD5Sum":"3ede40b984b18840030e3221f739deb6","Name":"firmware-hdd-3815d4b024-GPK8-4.1.x86_64.rpm","Release":"2025-09-22T02:29:50","Revision":"D","SHA1Sum":"89067d369f8d26e3ed35b0fcae06c335633e21d1","SHA256Sum":"961034c61d8c6ac996e37e634db202b240665ee625e6e390360a6364ef923a81","Size":"5MB","TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6XRUL960G","TargetGUID":"002340a5-434b-364d-5852-554c39363047","Type":"nvme"},{"Id":"KCM6XRUL7T68","TargetGUID":"002340a5-434b-364d-5852-554c37543638","Type":"nvme"},{"Id":"KCM6XRUL1T92","TargetGUID":"002340a5-434b-364d-5852-554c31543932","Type":"nvme"},{"Id":"KCM6XVUL3T20","TargetGUID":"002340a5-434b-364d-5856-554c33543230","Type":"nvme"},{"Id":"KCM6XRUL3T84","TargetGUID":"002340a5-434b-364d-5852-554c33543834","Type":"nvme"},{"Id":"KCM6XVUL800G","TargetGUID":"002340a5-434b-364d-5856-554c38303047","Type":"nvme"},{"Id":"KCM6XVUL6T40","TargetGUID":"002340a5-434b-364d-5856-554c36543430","Type":"nvme"},{"Id":"KCM6XVUL1T60","TargetGUID":"002340a5-434b-364d-5856-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:01:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>リセットの問題と定期的なメンテナンスファームウェアアップデートを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update</li></ul>","Lang":"cn"}],"Version":"GPK8"}],"SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e10cdbf81fd44dc998fb58d4e8932ad4"}]},{"ProductId":"b53b7ee55fb34198a842e8fa3306a80a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Addresses a hot plug reporting concern.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li><li>Remove Background Media Scan (BMS) with Super parity and Directed Offline Scan (DOS).</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Addresses a hot plug reporting concern.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li><li>Remove Background Media Scan (BMS) with Super parity and Directed Offline Scan (DOS).</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4625084","DateModified":"2025-08-02T20:00:00","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-1.1/CP067355.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-1.1/SHPEEVANSSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067355.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067355.scexe"],"MD5Sum":"48a805f6b6d6747e436ec226dfd0af73","Name":"firmware-hdd-cf0b6cabe1_0HPD4-1.1_amd64.deb","Release":"2025-08-03T00:52:40","Revision":"","SHA1Sum":"b01995c3c89881b0030a720b1415276927ce19f1","SHA256Sum":"e1342cad9b2d653dbe262cbc1c6e382923af9f4c773a64c381039801e300d33d","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000JWZHA","TargetGUID":"4d2340a5-3042-3031-3030-304a575a4841","Type":"sas"},{"Id":"MB016000JWZHE","TargetGUID":"4d2340a5-3042-3631-3030-304a575a4845","Type":"sas"},{"Id":"MB014000JWZHC","TargetGUID":"4d2340a5-3042-3431-3030-304a575a4843","Type":"sas"},{"Id":"MB012000JWZHB","TargetGUID":"4d2340a5-3042-3231-3030-304a575a4842","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:50:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Addresses a hot plug reporting concern</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Addresses a hot plug reporting concern</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Addresses a hot plug reporting concern</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"38eaa15c0df543118380b458ecff2b71"}]},{"ProductId":"8fe22752c5324386870794853904b4ba","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"ja","Value":"Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の認証情報を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerバージョン8.0.0以降および展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"23568016","DateModified":"2026-01-14T06:41:46","FileList":["CHIF/","CHIF/X64/","cp059557.exe","cp060558.exe","cp068350.exe","cp068352.exe","cp068359.exe","cp068361.exe","cp069950.xml","cpqsetup.exe","cp_data.xml","HPSUT/","HPSUT/X64/","install.xml","multisetup.dll","sut.msi","sutinstaller.exe","sut_cfg_default.dat","sut_config_en.xml","sut_config_ja.xml"],"MD5Sum":"c99b0657fc1292ff02e18425d8b46ef0","Name":"cp069950.exe","Release":"2026-01-14T06:38:48","Revision":"","SHA1Sum":"cad1b136fea6f87c2575a2f816a90d90fa805cba","SHA256Sum":"0d0e7bb6ed6a6b6ab2d54f76848dbef67d9abda4485c1028baf7220135ed1012","Size":"22MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4db0e49b"],"TypeOfChange":"1","Version":"6.5.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ol><li>Download the Smart Component (cpxxxxxx.exe) file to a local directory on the server where you want to install the software.</li><li>Change to the directory.</li><li>Run the .exe file by double-clicking it. A dialog box will display.</li><li>Click the &lsquo;Install&rsquo; button to install the Smart Update Tools.</li></ol>"},{"Lang":"ja","Value":"<ol><li>Smartコンポーネント (cpxxxxxx.exe)ファイルをサーバー上のソフトウェアをインストールしたいローカルディレクトリにダウンロードします。</li><li>ディレクトリに移動します。</li><li>.exeファイルをダブルクリックすることで実行します。ダイアログボックスが表示されます。</li><li>インストールボタンをクリックしてSmart Update Toolsをインストールします。</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Integrated Smart Update Tools for Windows x64"},{"Lang":"ja","Value":"Integrated Smart Update Tools for Windows x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-01T09:46:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"6.4.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"6.5.0.0"}],"SWKeys":[{"Name":"sut.exe","SWKeyExpectedPath":"%ProgramFiles%\\SUT\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1d990349c7364b459bb0ee658f8604a1"}]},{"ProductId":"a25f1000baab4c289a20555c0f1143b1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4365576","DateModified":"2025-11-17T06:17:12","FileList":["cp068734.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVANSSD4.rel"],"MD5Sum":"67b0152f07096f0d91ba8022e12ba11a","Name":"cp068734.exe","Release":"2025-11-17T06:12:16","Revision":"E","SHA1Sum":"44e80f8d3e3c47d83a932cccebd85748a9b968ed","SHA256Sum":"f8760e07694a1dd4c515f4962a56ec9d369998810083167f6307ebfeebaf6e14","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64） - MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB010000JWZHA","TargetGUID":"4d2340a5-3042-3031-3030-304a575a4841","Type":"sas"},{"Id":"MB012000JWZHB","TargetGUID":"4d2340a5-3042-3231-3030-304a575a4842","Type":"sas"},{"Id":"MB014000JWZHC","TargetGUID":"4d2340a5-3042-3431-3030-304a575a4843","Type":"sas"},{"Id":"MB016000JWZHE","TargetGUID":"4d2340a5-3042-3631-3030-304a575a4845","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T05:09:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"27683fdd56684a358c88bdcb0e19978f"}]},{"ProductId":"a5b53b4bfa36450dafe72d3912e27c73","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するIntel ice Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1103688","DateModified":"2025-09-15T16:24:59","FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.49.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/ice","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/0f","./usr/lib/.build-id/0f/3177ce41c5c27e133b2087c1c41e85bab3da7c","./usr/share/doc/ice","./usr/share/doc/ice/COPYING","./usr/share/doc/ice/README","./usr/share/doc/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"MD5Sum":"7daca181725c6bf5c93bd5a1021f65b3","Name":"kmod-ice-2.3.10-1.rhel9u5.x86_64.rpm","Release":"2025-09-15T16:17:08","Revision":"","SHA1Sum":"c23a3de98875acbc596ca1e7df946d232c78e06f","SHA256Sum":"add78bc75fe1fede5c9b6ef00b80bc26e9d00f4e0ede9305215644d3132f634d","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.3.10-1"},{"Bytes":"1104999","DateModified":"2025-09-15T16:30:06","FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.49.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/ice","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/da9dbfe44830e97481db25d6eea2709e6baab6","./usr/share/doc/ice","./usr/share/doc/ice/COPYING","./usr/share/doc/ice/README","./usr/share/doc/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"MD5Sum":"716ff4dc802a7b4cc3d39013e3b6ca0c","Name":"kmod-ice-2.3.10-1.rhel9u6.x86_64.rpm","Release":"2025-09-15T16:17:08","Revision":"","SHA1Sum":"a28ff67d7706075b1161772eb39dceda16596dbd","SHA256Sum":"2fd9af32c06e6d8928d9650e4b52297c7e6201c9196692b0840b814ad723e168","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.3.10-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Intel ice Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"Intel iceドライバーfor Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"Intel ice Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"},{"Dev":"12D3","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-12d380860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-22T08:05:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product now supports Red Hat Enterprise Linux 9.6.</li><li>This product now supports Software Cross Timestamping feature for E810.</li></ul>","Fixes":"<p>This product fixed an issue where the &#39;ethtool ethx&#39; displayed &#39;AUI&#39; with AOC cable, should display &#39;Fibre&#39;.</p>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、現在Red Hat Enterprise Linux 9.6をサポートします。</li><li>この製品は、E810のソフトウェアクロスタイムスタンプ機能をサポートするようになりました。</li></ul>","Fixes":"<p>この製品では、AOC ケーブル使用で「ethtool ethx」を実行すると、「Fibre」と表示されるはずが「AUI」と表示される問題が修正されました。</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product now supports Red Hat Enterprise Linux 9.6.</li><li>This product now supports Software Cross Timestamping feature for E810.</li></ul>","Fixes":"<p>This product fixed an issue where the &#39;ethtool ethx&#39; displayed &#39;AUI&#39; with AOC cable, should display &#39;Fibre&#39;.</p>","Lang":"cn"}],"Version":"1.17.8-1"},{"ReleaseNotes":[{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.3.10-1"}],"SWKeys":[{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2ad565dd72f746929e1608de67357a43"}]},{"ProductId":"7f5cc2735e814d67a516e6e72cb03eec","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This component provides support for the HPE Smart Array Gen10, Gen10Plus E-series and P-series controllers and Gen11 SR controllers"},{"Lang":"ja","Value":"このコンポーネントは、HPE SmartアレイGen10、Gen10Plus EシリーズおよびPシリーズのコントローラーとGen11 SRコントローラーのサポートを提供します"},{"Lang":"cn","Value":"This component provides support for the HPE Smart Array Gen10, Gen10Plus E-series and P-series controllers and Gen11 SR controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"772880","DateModified":"2025-11-24T04:37:17","FileList":["cp069767.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","smartpqi.cat","smartpqi.inf","SmartPqi.sys"],"MD5Sum":"ef65306895f38689c3962adeed1b8c34","Name":"cp069767.exe","Release":"2025-11-24T04:34:58","Revision":"B","SHA1Sum":"963c73b55d3488d9bad718aff1e7741a824557bb","SHA256Sum":"666767566d0a396fec23febc9375d015935e749c5e4f5d67628f9e0a0b06117b","Size":"754KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"TypeOfChange":"1","Version":"1016.10.0.1004"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2019"},{"Lang":"cn","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-24T04:08:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Windows Server 2025.</li><li>Added support to enable DMA remapping feature for Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fixed the issue that memory dump sometimes cannot be captured when Remote Key Management mode is enabled.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>  Windows Server 2025のサポートを追加しました。</li><li>Windows Server 2025のDMA再マッピング機能を有効にするサポートが追加されました。</li></ul>","Fixes":"<ul><li>リモートキー管理モードが有効になっている場合にメモリダンプをキャプチャーできない場合がある問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Windows Server 2025.</li><li>Added support to enable DMA remapping feature for Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fixed the issue that memory dump sometimes cannot be captured when Remote Key Management mode is enabled.</li></ul>","Lang":"cn"}],"Version":"1016.10.0.1004"},{"ReleaseNotes":[{"Enhancements":"<p>For windows 2019 driver only.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>For windows 2019 driver only.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>For windows 2019 driver only.</p>","Fixes":"","Lang":"cn"}],"Version":"1016.10.0.1004"}],"SWKeys":[{"Name":"SmartPqi.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"29e86213c3ab4e94b0b54906f7366af0"},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This component provides support for the HPE Smart Array Gen10, Gen10Plus E-series and P-series controllers and Gen11 SR controllers"},{"Lang":"ja","Value":"このコンポーネントは、HPE SmartアレイGen10、Gen10Plus EシリーズおよびPシリーズのコントローラーとGen11 SRコントローラーのサポートを提供します"},{"Lang":"cn","Value":"This component provides support for the HPE Smart Array Gen10, Gen10Plus E-series and P-series controllers and Gen11 SR controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"769392","DateModified":"2025-12-09T03:30:22","FileList":["cp069997.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","smartpqi.cat","smartpqi.inf","SmartPqi.sys"],"MD5Sum":"05212733c5b3c519649c810b2dda0985","Name":"cp069997.exe","Release":"2025-12-09T03:28:21","Revision":"B","SHA1Sum":"477a14d65202b76b84b49e850b46133af0bf0927","SHA256Sum":"0deae5957ab90585f81b2136b88d2e21f9da2747f0ca7b9a931cc4bbbaf51930","Size":"751KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"TypeOfChange":"1","Version":"1010.84.0.1012"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for  Windows Server 2016"},{"Lang":"ja","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for  Windows Server 2016"},{"Lang":"cn","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for  Windows Server 2016"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-09T02:26:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Fixed the inconsistent I/O errors observed in MPIO enabled physical drives during cable plug/unplug events in multipath scenarios.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>マルチパスシナリオでのケーブルの抜き差しイベント中に、MPIO対応の物理ドライブで観察される一貫性のないI/Oエラーを修正しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Fixed the inconsistent I/O errors observed in MPIO enabled physical drives during cable plug/unplug events in multipath scenarios.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1010.84.0.1012"},{"ReleaseNotes":[{"Enhancements":"<p>Support Windows 2016 only.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support Windows 2016 only.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support Windows 2016 only.</p>","Fixes":"","Lang":"cn"}],"Version":"1010.84.0.1012"}],"SWKeys":[{"Name":"SmartPqi.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c523e081ab344bc4b4bc9d5686ff0090"},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This component provides support for the HPE Smart Array Gen10, Gen10Plus E-series and P-series controllers and Gen11 SR controllers"},{"Lang":"ja","Value":"このコンポーネントは、HPE SmartアレイGen10、Gen10Plus EシリーズおよびPシリーズのコントローラーとGen11 SRコントローラーのサポートを提供します"},{"Lang":"cn","Value":"This component provides support for the HPE Smart Array Gen10, Gen10Plus E-series and P-series controllers and Gen11 SR controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"808648","DateModified":"2025-12-16T11:08:16","FileList":["cp069362.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","smartpqi.cat","smartpqi.inf","SmartPqi.sys"],"MD5Sum":"090fd6b8badb0573d61ef989d973e7f3","Name":"cp069362.exe","Release":"2025-12-16T11:05:40","Revision":"B","SHA1Sum":"ce1a48c7cc98e0bea07bf4cc5a1a1128ea4118e6","SHA256Sum":"341ae7894763b4746dc34d62e7b4973039048e68d37c132bbeb802433eb3ee6e","Size":"789KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"TypeOfChange":"1","Version":"1016.30.0.1014"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>For downgrade operation from 1016.24.x to lower version, the user message in dialog box will be displayed as upgrade/rewrite/downgrade based on the driver file version available in the &quot;%systemroot%\\system32\\drivers&quot; path. This is an expected behavior as the expected location path is modified to &quot;%systemdrive%\\cpqsystem\\pnpdrvs&quot; from 1016.24.x version.</p><p>There is no impact on the functionality of driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> </p><p>1016.24.xからのダウングレード操作の場合、ダイアログボックスのユーザーメッセージは、\"%systemroot%\\system32\\drivers\"パスで使用可能なドライバーファイルのバージョンに基づいて、アップグレード/書き換え/ダウングレードとして表示されます。これは、想定される場所のパスが1016.24.xバージョンから\"%systemdrive%\\cpqsystem\\pnpdrvs\"に変更されたことによる、想定される動作です。</p><p>ドライバーインストールの機能には影響ありません。</p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>For downgrade operation from 1016.24.x to lower version, the user message in dialog box will be displayed as upgrade/rewrite/downgrade based on the driver file version available in the &quot;%systemroot%\\system32\\drivers&quot; path. This is an expected behavior as the expected location path is modified to &quot;%systemdrive%\\cpqsystem\\pnpdrvs&quot; from 1016.24.x version.</p><p>There is no impact on the functionality of driver installation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2022 and Windows Server 2025"},{"Lang":"ja","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2022 and Windows Server 2025"},{"Lang":"cn","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2022 and Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T09:26:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.<br />&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"1016.24.0.1002"},{"ReleaseNotes":[{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1016.30.0.1014"}],"SWKeys":[{"Name":"SmartPqi.sys","SWKeyExpectedPath":"%systemdrive%\\cpqsystem\\pnpdrvs"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6c1e95ec13354cdd998cd911da77c3d9"}]},{"ProductId":"61738b9f52854162bc00b831995dd260","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Power Coordination algorithm which ensures the drive will properly negotiate power with SPL-2 and newer compliant controllers.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Power Coordination algorithm which ensures the drive will properly negotiate power with SPL-2 and newer compliant controllers.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"4758360","DateModified":"2025-08-03T01:46:15","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-1.1/CP067342.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-1.1/SSKYBT512EDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067342.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067342.scexe"],"MD5Sum":"915653386315ffa2ff191fbb2e1d2c64","Name":"firmware-hdd-b1c9eaf74c_0HPDB-1.1_amd64.deb","Release":"2025-08-03T06:39:08","Revision":"","SHA1Sum":"83cf9c1d4002c8f9af45a515af4cf6ec87f8feaf","SHA256Sum":"52970b177e197157cda4ac39ae0093e94ef8d6918b97868327e165d99cbbfb47","Size":"4MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"CP041696.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG001800JWJNR","TargetGUID":"452340a5-3047-3130-3830-304a574a4e52","Type":"sas"},{"Id":"EG002400JWJNT","TargetGUID":"452340a5-3047-3230-3430-304a574a4e54","Type":"sas"},{"Id":"EG002400MXJQT","TargetGUID":"452340a5-3047-3230-3430-304d584a5154","Type":"sas"},{"Id":"EG001800JXLWB","TargetGUID":"452340a5-3047-3130-3830-304a584c5742","Type":"sas"},{"Id":"EG002400JXLWC","TargetGUID":"452340a5-3047-3230-3430-304a584c5743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:30:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f3498c7cc8654d6f803ec92295c121d4"}]},{"ProductId":"4e3802b484324394ada6924af481323b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作するHPE Intel icea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1723528","DateModified":"2025-11-16T11:08:15","FileList":["cp069535.xml","cpqsetup.exe","cp_data.xml","icea.cat","icea.inf","icea.sys","iceamsg.dll","install.xml","manifest_icea.man","nicdrvr.dll"],"MD5Sum":"817ad215b05cfed13e026f971e0260d5","Name":"cp069535.exe","Release":"2025-11-16T10:53:35","Revision":"B","SHA1Sum":"be3a5483cd38c5f505056fd4a90129265e4e0ed4","SHA256Sum":"fa3726c99a38c195e871bd6decb85fb4b186c0bed18327b348b3b77320ad39df","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"TypeOfChange":"1","Version":"1.18.86.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icea Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"Intel iceaドライバーfor Microsoft Windows Server 2025"},{"Lang":"cn","Value":"Intel icea Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:50:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"cn"}],"Version":"1.18.86.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"cn"}],"Version":"1.18.86.0"}],"SWKeys":[{"Name":"icea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\icea.inf_amd64_0d313568beecbfb3"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a752619acd0a44a19a08372d86280f66"}]},{"ProductId":"4c6271d05e004c45ba29ce1cb206f9a2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM2000GEFRA"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MM2000GEFRA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4145588","DateModified":"2025-08-03T02:11:21","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-1.1/CP067347.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-1.1/SAVGRTG9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067347.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067347.scexe"],"MD5Sum":"95b98c7615d7e15ca6d32b7e9f5e132a","Name":"firmware-hdd-ec908c3650_0HPG9-1.1_amd64.deb","Release":"2025-08-03T07:03:27","Revision":"","SHA1Sum":"6e965e87856dd28e4ba1e6be08f8de99640e8ee9","SHA256Sum":"9e5885a0f0361e065183795e31e30a1e4a0e1a19b1b0eaa49c534998ceeea225","Size":"3MB","TargetGUIDs":["002340a5-4d00-324d-3030-304745465241"],"TypeOfChange":"1","Version":"HPG9"}],"Installation":{"Command":"CP040273.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MM2000GEFRA Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MM2000GEFRA Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM2000GEFRA","TargetGUID":"002340a5-4d00-324d-3030-304745465241","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:38:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up</li></ul>","Lang":"cn"}],"Version":"HPG9"}],"SWKeys":[{"Name":"MM2000GEFRA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ab311def07be48c3927cbde75ea204c6"}]},{"ProductId":"912bdc2895264227ab4d6d2895102ac1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following NVME drive models: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) -&nbsp;VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK3<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) -&nbsp;VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK3<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5984248","DateModified":"2025-11-18T02:23:13","FileList":["cp068636.xml","cpqsetup.exe","KPE80X0AHPK5.rel","payload.json","setup.dll"],"MD5Sum":"6bdc45693fc8e1550115b3da831fabfd","Name":"cp068636.exe","Release":"2025-11-18T02:17:52","Revision":"G","SHA1Sum":"461944992100242d97babe2abc7fbe320ee1a718","SHA256Sum":"3ff362b26afe88ce3714c2b38fad6888b4bb70f19c4f630d729e6e86803710c1","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO000960KXAVL","TargetGUID":"562340a5-304f-3030-3936-304b5841564c","Type":"nvme"},{"Id":"MO000800KXAVN","TargetGUID":"4d2340a5-304f-3030-3830-304b5841564e","Type":"nvme"},{"Id":"MO001600KXAVT","TargetGUID":"4d2340a5-304f-3130-3630-304b58415654","Type":"nvme"},{"Id":"MO003200KXAVU","TargetGUID":"4d2340a5-304f-3330-3230-304b58415655","Type":"nvme"},{"Id":"MO006400KXAVV","TargetGUID":"4d2340a5-304f-3630-3430-304b58415656","Type":"nvme"},{"Id":"VO003840KXAVQ","TargetGUID":"562340a5-304f-3330-3834-304b58415651","Type":"nvme"},{"Id":"VO007680KXAVR","TargetGUID":"562340a5-304f-3730-3638-304b58415652","Type":"nvme"},{"Id":"VO001920KXAVP","TargetGUID":"562340a5-304f-3130-3932-304b58415650","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T08:51:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK5"}],"SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8bf4346a35984e31809f5fa03188dce7"}]},{"ProductId":"fd79732b69c747a4ba4278e32ef12a49","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントには、Mircosoft Windows Server 2025用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"},{"Lang":"cn","Value":"This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1106464","DateModified":"2025-11-17T04:07:22","FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp069011.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"6d24ba68b86e77ebe9e5b00966ac17c9","Name":"cp069011.exe","Release":"2025-11-17T03:52:37","Revision":"","SHA1Sum":"cca7c69fe4ad96dede384ddd830249f1f0097afb","SHA256Sum":"ced1d9f305167a5846231927e5eacd652172ce3ac5145e982f5829ab1855a55e","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"235.1.122.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"Broadcom NetXtreme-Eドライバーfor Microsoft Windows Server 2025"},{"Lang":"cn","Value":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41593","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41592","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e124","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e124","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41595","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41597","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d8","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"1760","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e41760","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D6","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d6","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d7","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41593","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41592","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41595","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41597","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41596","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1808","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180814e41599","Type":"pci","Ven":"14e4"},{"Dev":"1808","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180814e41598","Type":"pci","Ven":"14e4"},{"Dev":"1809","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180914e41599","Type":"pci","Ven":"14e4"},{"Dev":"1809","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180914e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1751","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41751","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41599","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41598","Type":"pci","Ven":"14e4"},{"Dev":"1807","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180714e41599","Type":"pci","Ven":"14e4"},{"Dev":"1807","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180714e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1808","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-180800000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-181B00000000","Type":"pci","Ven":"14E4"},{"Dev":"1809","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-180900000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-181B00000000","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-02T03:12:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances to improve user mode RDMA abortive cleanup.</li><li>This product enhances FW logging to host to work across device reset.</li></ul>","Fixes":"<ul><li>This product fixes issue where BSOD (Blue Screen of Death) occurs when install Windows Server 2025 OS on ISCSI LUN.</li><li>This product fixes issue where packet drops is seen when jumbo frame is enabled.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、ユーザーモードのRDMA中止クリーンアップを改善するように強化されています。</li><li>この製品は、デバイスのリセット後も機能するようにホストへのFWログ記録を強化します。</li></ul>","Fixes":"<ul><li>この製品は、Windows Server 2025 OS を ISCSI LUNにインストールするとBSOD(ブルー スクリーン) が発生する問題を修正します。</li><li>この製品は、ジャンボフレームが有効になっている場合にパケットドロップが発生する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances to improve user mode RDMA abortive cleanup.</li><li>This product enhances FW logging to host to work across device reset.</li></ul>","Fixes":"<ul><li>This product fixes issue where BSOD (Blue Screen of Death) occurs when install Windows Server 2025 OS on ISCSI LUN.</li><li>This product fixes issue where packet drops is seen when jumbo frame is enabled.</li></ul>","Lang":"cn"}],"Version":"233.0.148.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"235.1.122.0"}],"SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"299e3fe8b55e4a29be6501b2933e902a"}]},{"ProductId":"b2dec2e98a4f489c96311517a4bf5571","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2025用のドライバーを含みます。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2458256","DateModified":"2025-11-17T01:49:18","FileList":["cp068342.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"aa324c690a14fe2f07e42b60853447d3","Name":"cp068342.exe","Release":"2025-11-17T01:34:47","Revision":"","SHA1Sum":"71cb5c62d87cb12a12665785b57b5f32df51e954","SHA256Sum":"d39338fb3ea6866975f9b42e7d1d937d872bd53c0de04786f807c70e9c0da09b","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.7.26882.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2025"},{"Lang":"cn","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815900246","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-13T02:38:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"en"},{"Enhancements":"<p>Windows上のDOCAテレメトリライブラリに対するサポートが追加されました。</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"ja"},{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"cn"}],"Version":"25.4.26768.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"cn"}],"Version":"25.7.26882.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3bfb1a3d2e2145d79dda4501869de506"}]},{"ProductId":"8c2329b4625b415f9c19a0c86db985e1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーは、オペレーティングシステムがロックアップした場合にサーバーをリセットするASRハードウェアタイマーを管理します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"597088","DateModified":"2025-11-18T03:24:15","FileList":["cp069723.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"MD5Sum":"dce394ea2003d529e669f4a47fa1ac96","Name":"cp069723.exe","Release":"2025-11-18T03:22:34","Revision":"I","SHA1Sum":"d31b6e8c5a5e394c51f9ea8c801fa31ffa426595","SHA256Sum":"2c18f6089adac226fd70ebb4b364fe9bd1a459b6b27f1719dd4cb4f623e27117","Size":"583KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.1.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーfor Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T03:20:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"}],"SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"62b2f5fb3af64069a682ab0c56316de2"}]},{"ProductId":"f3c8e04f69244d2193f6f4cd088bef7f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB006000JYDNF, MB008000JYDPC and MB010000JYDNH"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB006000JYDNF, MB008000JYDPC and MB010000JYDNH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"4899952","DateModified":"2025-08-02T20:28:50","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-1.1/CP067357.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-1.1/SCIMARBPESD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067357.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067357.scexe"],"MD5Sum":"20bb94c10a79f4aa81f3ab4babfc3b76","Name":"firmware-hdd-b04df66fe9_0HPD5-1.1_amd64.deb","Release":"2025-08-03T01:22:56","Revision":"","SHA1Sum":"eef7101fd703a97ec08c8375f70e23de51eb1bcd","SHA256Sum":"1bb93ffaeabda40bf23db3d278ce2406989431a4c6f91984b217d24376b3248f","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000JYDNF","TargetGUID":"4d2340a5-3042-3630-3030-304a59444e46","Type":"sas"},{"Id":"MB008000JYDPC","TargetGUID":"4d2340a5-3042-3830-3030-304a59445043","Type":"sas"},{"Id":"MB010000JYDNH","TargetGUID":"4d2340a5-3042-3031-3030-304a59444e48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:52:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e2237bdc820c4da7b911ebe0f454af49"}]},{"ProductId":"41b0e237fef743bfa73e14fb19e3c9ff","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、HPE Broadcom NetXtreme-Eデバイスfor Windows Server 2025のドライバーが含まれています。"},{"Lang":"cn","Value":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1106200","DateModified":"2025-11-17T03:00:16","FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp068541.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"06610aabe4b87c9273bc692b5e718164","Name":"cp068541.exe","Release":"2025-11-17T02:45:49","Revision":"","SHA1Sum":"cc000b098bbe20a59ff0c371fd5c108e33c37ab9","SHA256Sum":"8769b222dd36e74a5e281d898c4575da8add97c3df06b9ae0a9d1f6ef52e1b9c","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"235.1.122.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for Windows Server 2025"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-27T06:13:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances to improve user mode RDMA abortive cleanup.</li><li>This product enhances FW logging to host to work across device reset.</li></ul>","Fixes":"<p>This product fixes issue where packet drops is seen when jumbo frame is enabled.</p>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、ユーザーモードのRDMA中止クリーンアップを改善するように強化されています。</li><li>この製品は、デバイスのリセット後も機能するようにホストへのFWログ記録を強化します。</li></ul>","Fixes":"<p>この製品は、ジャンボフレームが有効になっている場合にパケットドロップが発生する問題を修正します。</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances to improve user mode RDMA abortive cleanup.</li><li>This product enhances FW logging to host to work across device reset.</li></ul>","Fixes":"<p>This product fixes issue where packet drops is seen when jumbo frame is enabled.</p>","Lang":"cn"}],"Version":"233.0.148.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"235.1.122.0"}],"SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"12c7ef0d7cf542ff8965db1d4f300fe8"}]},{"ProductId":"9dea06267ae9459899ac2a4c5391b558","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA,&nbsp; EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA,&nbsp; EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3593304","DateModified":"2025-08-03T01:08:05","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-1.1/CP067332.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-1.1/KAPM5ALSHPDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067332.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067332.scexe"],"MD5Sum":"c8717df72927239d588deb61dfdac6de","Name":"firmware-hdd-9ad359dac1_0HPDB-1.1_amd64.deb","Release":"2025-08-03T06:02:09","Revision":"","SHA1Sum":"4de019ba4156453a9a42e01ff805e497ddf64667","SHA256Sum":"1e7a89ae69540f7109676b04e802c7b0632d7ead994dc8299cd67e75c302b5d5","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"CP040601.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO007680JWTBP","TargetGUID":"562340a5-304f-3730-3638-304a57544250","Type":"sas"},{"Id":"MO006400JWTCD","TargetGUID":"4d2340a5-304f-3630-3430-304a57544344","Type":"sas"},{"Id":"VO003840JWTBN","TargetGUID":"562340a5-304f-3330-3834-304a5754424e","Type":"sas"},{"Id":"MO003200JWTBU","TargetGUID":"4d2340a5-304f-3330-3230-304a57544255","Type":"sas"},{"Id":"EO003200JWTCC","TargetGUID":"452340a5-304f-3330-3230-304a57544343","Type":"sas"},{"Id":"VO001920JWTBL","TargetGUID":"562340a5-304f-3130-3932-304a5754424c","Type":"sas"},{"Id":"MO001600JWTBT","TargetGUID":"4d2340a5-304f-3130-3630-304a57544254","Type":"sas"},{"Id":"EO001600JWTCB","TargetGUID":"452340a5-304f-3130-3630-304a57544342","Type":"sas"},{"Id":"VO000960JWTBK","TargetGUID":"562340a5-304f-3030-3936-304a5754424b","Type":"sas"},{"Id":"MO000800JWTBR","TargetGUID":"4d2340a5-304f-3030-3830-304a57544252","Type":"sas"},{"Id":"EO000800JWTCA","TargetGUID":"452340a5-304f-3030-3830-304a57544341","Type":"sas"},{"Id":"MO000400JWTBQ","TargetGUID":"4d2340a5-304f-3030-3430-304a57544251","Type":"sas"},{"Id":"EO000400JWTBV","TargetGUID":"452340a5-304f-3030-3430-304a57544256","Type":"sas"},{"Id":"MO001920JWWWV","TargetGUID":"4d2340a5-304f-3130-3932-304a57575756","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:57:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b3524861ce434e37a7b785ec0fa88c96"}]},{"ProductId":"c5181c3bc0654e9db312aa6200639426","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U44_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.72 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9251064","DateModified":"2026-01-14T01:40:16","FileList":["cp070183.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U44_3.72_01_09_2026.signed.flash"],"MD5Sum":"4b5386f3607b7e8ab11af1123c6fb278","Name":"cp070183.exe","Release":"2026-01-14T01:38:44","Revision":"","SHA1Sum":"f57d3fdc7006e69e1da5a146f0cc9516327f5a4b","SHA256Sum":"c9d7837734d215cc7732bc3972fbbcbe682d799bafad5b8701d88b062ef222fd","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.72_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"ja","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T09:30:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.103と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.70_08-08-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_01-09-2026"}],"SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"fcfe600bff4e40c8ad04598571152acb"}]},{"ProductId":"f201f1f45a1041f9819da1901ffe255f","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v4.00 (01/09/2026)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34088951","DateModified":"2026-01-12T20:52:26","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.00_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.00_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.00_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.00_2026_01_09-1.1/A42_4.00_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.00_2026_01_09-1.1/CP070350.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.00_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.00_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.00_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.00_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070350.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070350.scexe"],"MD5Sum":"af9a7764181a44343e843790ab893bf0","Name":"firmware-system-a42-4.00_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T02:44:47","Revision":"","SHA1Sum":"8a6b4fa7252449d380a7ad9f579b836d67d0cc37","SHA256Sum":"51b8ff72a71a29ea8b80df0c37ac6e33aa38cc121365237d0b60f3dc4d2a182f","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus（A42）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:44:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。</p><p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.92_11-27-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fa32e7a0ba3340949f96f5c34bfbf7d4"}]},{"ProductId":"8a08f6182dea4f4eb893d0fcf7833007","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KXG50ZNV256G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AAGA4103.sig","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AAGA4103"},{"DeviceName":"KXG50ZNV512G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AAGA4103.sig","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AAGA4103"},{"DeviceName":"KXG50ZNV1T","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AAGA4103.sig","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AAGA4103"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Disk"},{"Lang":"ja","Value":"ファームウェア - ストレージ ディスク"},{"Lang":"cn","Value":"固件 - 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: KXG50ZNV256G, KXG50ZNV512G and KXG50ZNV1T Drives that can be installed directly on HPE ProLiant m750 System running a supported Microsoft Windows Operating System installed in HPE Moonshot 1500 chassis."},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: KXG50ZNV256G, KXG50ZNV512G and KXG50ZNV1T Drives that can be installed directly on HPE ProLiant m750 System running a supported Microsoft Windows Operating System installed in HPE Moonshot 1500 chassis."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7636408","DateModified":"2026-01-22T01:41:21","FileList":["AAGA4103.sig","cp070452.xml","cpqsetup.exe","ilorest_chif.dll","payload.json"],"MD5Sum":"8622e5afa820558e749cebe26f12ef22","Name":"cp070452.exe","Release":"2026-01-22T01:23:33","Revision":"B","SHA1Sum":"d2e02b32dc5de3caf81a26fb208aa8850adb2fef","SHA256Sum":"21b4ffe7a85a3856be6da9def8b9cc3fed914816b0905844f42433999e538745","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"AAGA4103"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Microsoft Windows - KXG50ZNV256G, KXG50ZNV512G and KXG50ZNV1T Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Microsoft Windows - KXG50ZNV256G、 KXG50ZNV512GおよびKXG50ZNV1Tドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"9000"},"SupportedDevices":[{"Id":"KXG50ZNV256G","TargetGUID":"002340a5-584b-3547-305a-4e5632353647","Type":"nvme"},{"Id":"KXG50ZNV512G","TargetGUID":"002340a5-584b-3547-305a-4e5635313247","Type":"nvme"},{"Id":"KXG50ZNV1T","TargetGUID":"002340a5-0000-584b-4735-305a4e563154","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"Microsoft Windows 11","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-22T01:20:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"AAGA4103"},{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"AAGA4103"}],"SWKeys":[{"Name":"KXG50ZNV256G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KXG50ZNV512G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KXG50ZNV1T","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d92e1c665e8f4e629035cb196f961420"}]},{"ProductId":"8ec761f6af0748368439ffd510490ba3","Versions":[{"DeviceClass":"42fc70be-bb87-4bdb-8e7c-db1c9af52957","Devices":{"Device":[{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.0.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000242","Version":"2.0.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.0.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"2.0.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.0.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000221","Version":"2.0.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Management"},{"Lang":"ja","Value":"ファームウェア - マネジメント"},{"Lang":"cn","Value":"固件 - 管理"}],"Description":[{"Lang":"en","Value":"This component provides updated firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated firmware that can be installed directly on supported Operating Systems. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"926088","DateModified":"2026-01-05T13:56:20","FileList":["ACCE_2.0.0s.bin","cp070132.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"6ee31f75b3beb76195ae2bd808fc7aad","Name":"cp070132.exe","Release":"2026-01-05T13:54:30","Revision":"A","SHA1Sum":"cb6842c883006770104b54311a7c8fe890f6dfbb","SHA256Sum":"8990c271752d275603d09c4cc798552d421ffba91290e1b49bf72497f91d1085","Size":"904KB","TargetGUIDs":["00000000-0000-0000-0000-000000000242","00000000-0000-0000-0000-00000000023a","00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"2.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.</p><p>iLO reset is required after firmware update to display the current firmware version in iLO GUI.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。</p><p>現在のファームウェアバージョンをiLO GUIに表示するには、ファームウェアアップデート後にiLOをリセットする必要があります。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.</p><p>iLO reset is required after firmware update to display the current firmware version in iLO GUI.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 -  HPE Edgeline Chassis Controller Firmware"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE Edgelineシャーシコントローラーファームウェア"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 -  HPE Edgeline Chassis Controller Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-05T13:51:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"cn"}],"Version":"2.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"cn"}],"Version":"2.0.0"}],"SWKeys":[{"Name":"ACCE","SWKeyExpectedPath":"firmware:ACC"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"FTP","Model":"FTP-Only System"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H11","Model":"HPE ProLiant EL8000s"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"3171b3929c8b46819cdb307e27c675d9"}]},{"ProductId":"5c10ef42611f4cada08e038ec64fbce6","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770068","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770068","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770069","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770069","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770070","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770070","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770071","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770071","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770073","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770073","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770072","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770072","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770074","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770074","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770077","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770077","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770077","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770078","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770078","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770078","Version":"8.65.21"}]},"MinimumActiveVersion":"8.55.12","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、HPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするためのユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v8.65.21.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.65.7.0, and UEFI: 6.1.8.2.</p>"},{"Lang":"ja","Value":"<p>This software package contains combo image v8.65.21.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.65.7.0, and UEFI: 6.1.8.2.</p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v8.65.21.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.65.7.0, and UEFI: 6.1.8.2.</p>"}],"Files":[{"Bytes":"1951754","DateModified":"2024-12-11T01:46:22","FileList":["payload.json","ql_ah_mbi_open_8.65.21_pldm.HPb","ql_ah_mbi_open_8.65.21_pldm.xml"],"MD5Sum":"013a07faf6995d0bc4fe102a890f8937","Name":"ql_ah_mbi_open_8.65.21_pldm.fwpkg","Release":"2024-12-11T01:43:39","Revision":"","SHA1Sum":"4a5982651c781b8db0fb1829ec01a4bf335e0bb0","SHA256Sum":"93e258a0ddbb7ec12a6ed335ffe61e1ea0ca197c5aa212737b436c0dd2f94f0a","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-80f010770068","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-80f010770069","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-80f010770070","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-80f010770071","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-809010770073","a6b1a447-382a-5a4f-1077-80f010770073","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-80f010770072","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-80f010770074","a6b1a447-382a-5a4f-1077-807010770077","a6b1a447-382a-5a4f-1077-809010770077","a6b1a447-382a-5a4f-1077-80f010770077","a6b1a447-382a-5a4f-1077-807010770078","a6b1a447-382a-5a4f-1077-809010770078","a6b1a447-382a-5a4f-1077-80f010770078"],"TypeOfChange":"1","Version":"8.65.21"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>このファームウェアパッケージには最小バージョン（コンボイメージv8.55.12）が必要であることに注意してください。最初にファームウェアをアップデートするには、次のリンクを参照してください。</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Marvell FastLinQ Firmware Package for Arrowhead adapters"},{"Lang":"ja","Value":"Arrowheadアダプター用Marvell FastLinQファームウェアパッケージ"},{"Lang":"cn","Value":"Marvell FastLinQ Firmware Package for Arrowhead adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T04:03:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"8.65.14"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.65.21"}],"SWKeys":[{"Name":"MARVELL_FLQ_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"bc48d0c6a7274ea890d1070742ae9a44"}]},{"ProductId":"aacf76bfa7674de086e8a84063eadb98","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"DL20ML30Gen10SPS_05.01.05.103.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2005611","DateModified":"2025-07-24T02:27:14","FileList":["DL20ML30Gen10SPS_05.01.05.103.signed.bin","DL20ML30Gen10SPS_05.01.05.103.xml","payload.json"],"MD5Sum":"a358f8fb5bea12ec4fe370b53a5c8484","Name":"DL20ML30Gen10SPS_05.01.05.103.fwpkg","Release":"2025-07-24T02:25:31","Revision":"","SHA1Sum":"ec35db27fe71bae2c0a45332c8063f5f228bae85","SHA256Sum":"aac1c46ae909251f6ad8448b13a229fad61baa94deaff6ad075f577bf258f829","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Servers"},{"Lang":"ja","Value":"ROMフラッシュ ファームウェアパッケージ - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-24T02:25:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 05.01.05.005は、システムROM 3.50 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"05.01.05.103"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"e553de6b27bd43e982e1d4c580b136a3"}]},{"ProductId":"5829ee37bc994558baa6a98dd52b6154","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20260570","DateModified":"2025-04-16T05:38:05","FileList":["/CP066752_BUILD_1.data","/CP066752.vmexe64","/CP066752.vmfile","/CP066752_VMw.zip","/CP066752.xml","/payload.json","/CP066752_VMw.zip/index.xml","/CP066752_VMw.zip/vendor-index.xml","/CP066752_VMw.zip/metadata.zip","/CP066752_VMw.zip/vib20/CP066752/HPE_bootbank_CP066752_HPD9.1-8.0.0.20613240.vib","/CP066752_VMw.zip/metadata.zip/vendor-index.xml","/CP066752_VMw.zip/metadata.zip/vmware.xml","/CP066752_VMw.zip/metadata.zip/vibs/CP066752-2221792242571695822.xml","/CP066752_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066752_HPD9.1-8.0.0.20613240.xml"],"MD5Sum":"ceee222a410b87e733237ae13e53da62","Name":"CP066752.zip","Release":"2025-04-16T05:37:12","Revision":"C","SHA1Sum":"06c0f9dd83fe2cec1046d7bd25f295ac3990329a","SHA256Sum":"49442115198fc0b0915cfc12bd5828884207638e76ed051e119d8a9175aa3f7e","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP066752","Version":"HPD9.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP041692.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EG001200JWJNQ","TargetGUID":"452340a5-3047-3130-3230-304a574a4e51","Type":"sas"},{"Id":"EG000600JWJNP","TargetGUID":"452340a5-3047-3030-3630-304a574a4e50","Type":"sas"},{"Id":"EG001200MXJQU","TargetGUID":"452340a5-3047-3130-3230-304d584a5155","Type":"sas"},{"Id":"EG000600JXLVV","TargetGUID":"452340a5-3047-3030-3630-304a584c5656","Type":"sas"},{"Id":"EG001200JXLWA","TargetGUID":"452340a5-3047-3130-3230-304a584c5741","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-11T09:33:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4e0d725d6b2547bf98a536bf6b6b9692"}]},{"ProductId":"332a1cff050e45b999d3c0f17ade482b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP7."},{"Lang":"ja","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP7."},{"Lang":"cn","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP7."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"42206","DateModified":"2025-12-12T07:01:14","FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-235.1.164.14.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"MD5Sum":"dfe9763c5922411e45877b07479b046a","Name":"libbnxt_re-235.1.164.14-sles15sp7.x86_64.rpm","Release":"2025-12-12T06:59:05","Revision":"","SHA1Sum":"e0675558ff7cbc81f7dde1d1c267b0f5762fc4b4","SHA256Sum":"cb5b0f12f289bc3cea4668512e26d2d99110310915f42f336e660a17e5fc3c7b","Size":"41KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"ja","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"cn","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP7"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP7"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP7"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-12T04:04:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"f1eb364b44104b1681f2888a5aa237ce"}]},{"ProductId":"2079058db213445cb2b49d341b2df92d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"ja","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 10."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"231232","DateModified":"2025-09-15T16:00:27","FileList":["./etc/depmod.d/kmod-iavf.conf","./etc/modprobe.d/iavf.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/iavf/iavf.ko","./usr/share/doc/kmod-iavf","./usr/share/doc/kmod-iavf/COPYING","./usr/share/doc/kmod-iavf/README","./usr/share/doc/kmod-iavf/pci.updates","./usr/share/man/man7/iavf.7.gz","./usr/share/smartupdate/kmod-iavf/component.xml"],"MD5Sum":"0fd0d59afa27f50f6c6932f7775fffd4","Name":"kmod-iavf-4.13.16-1.rhel10u0.x86_64.rpm","Release":"2025-09-15T15:56:05","Revision":"","SHA1Sum":"19ef60203391c038aa6cadb1254b49c8f1fbce52","SHA256Sum":"a6ec20c3f083be3df36bc3d9f05135d703f0b5d68ba9e889d702640449dcdb19","Size":"225KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec52bf8d0b"],"TypeOfChange":"1","Version":"4.13.16-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 10"},{"Lang":"ja","Value":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 10"},{"Lang":"cn","Value":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"15FF","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15ff8086000c","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37cd","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"0dd5","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"12D3","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-12d380860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-22T08:15:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Red Hat Enterprise Server 10をサポートするための初回リリースです。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"cn"}],"Version":"4.13.14-1"},{"ReleaseNotes":[{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"4.13.16-1"}],"SWKeys":[{"Name":"kmod-iavf","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6e9e3c42100e4bec995bca9397e9299d"}]},{"ProductId":"6b2dbf58581246349103e902007d06c0","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000GXMTK and MB020000GXMTQ"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB018000GXMTKおよびMB020000GXMTQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4054728","DateModified":"2025-11-16T13:18:16","FileList":["cp068740.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SLONGSPKETG3.rel"],"MD5Sum":"94b633fc59864415d46e2ff1e443da6a","Name":"cp068740.exe","Release":"2025-11-16T13:12:03","Revision":"C","SHA1Sum":"ccd011f0dd5486cf962427728d45682ccbc8654c","SHA256Sum":"0f9828da4575730c65185ef212845802818e87a98b31768ded464df8ac7b544a","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB018000GXMTK and MB020000GXMTQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB018000GXMTKおよびMB020000GXMTQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB020000GXMTQ","TargetGUID":"4d2340a5-3042-3032-3030-3047584d5451","Type":"sata"},{"Id":"MB018000GXMTK","TargetGUID":"4d2340a5-3042-3831-3030-3047584d544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T05:39:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"129ea91123b74a9c988498381bdcc34d"}]},{"ProductId":"e0019db6f6e24588a441b6cb4e743087","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"This component provides the driver for the Microchip/Microsemi PCIe Gen 4 Switch."},{"Lang":"ja","Value":"このコンポーネントは、Microchip/Microsemi PCIe Gen4スイッチのドライバーを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"573408","DateModified":"2025-11-18T07:25:13","FileList":["cp069731.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"MD5Sum":"df3f14a800a00b26c81f6e26004b2a80","Name":"cp069731.exe","Release":"2025-11-18T07:23:02","Revision":"C","SHA1Sum":"3a45e0409e5c0314b2b302045ab56bfc5b804c22","SHA256Sum":"a0bdee7587e4190aefcaaa2aaa68750c6aef85877ca2f92e4594a73b852f3550","Size":"559KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"TypeOfChange":"0","Version":"1.0.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.<br />Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.<br />Click the &quot;Install&quot; button to perform the driver installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<br />インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。<br />インストールボタンをクリックしてドライバーインストールを実行します。</p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2016 and Server 2019"},{"Lang":"ja","Value":"Switchtec PCIeスイッチ管理ドライバーfor Microsoft Windows Server 2016およびServer 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"100"},"SupportedDevices":[{"Dev":"4000","SubDev":"4000","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-400011f84000","Type":"pci","Ven":"11F8"},{"Dev":"4052","SubDev":"4052","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-405211f84052","Type":"pci","Ven":"11F8"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T07:16:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SBOM要件をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.0"}],"SWKeys":[{"Name":"Switchtec.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ff7435a744224d6aac8e96029a9ca56b"}]},{"ProductId":"5ac3ee90b2184fa9828f960cd9d17840","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4337784","DateModified":"2025-11-17T03:48:16","FileList":["cp068653.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SSKYBT512ND9.rel"],"MD5Sum":"b1a57de7a313c11ad4230c4c0ad72b2d","Name":"cp068653.exe","Release":"2025-11-17T03:42:57","Revision":"B","SHA1Sum":"ec8140c31ab69e09487811a2b32576841b5f3a35","SHA256Sum":"fa56b2951d63bd48e23d3d92b32fe35a74ddb4b6c3c0d69ca662a8306ad9d885","Size":"4MB","TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EG001200MXJQU","TargetGUID":"452340a5-3047-3130-3230-304d584a5155","Type":"sas"},{"Id":"EG000600JXLVV","TargetGUID":"452340a5-3047-3030-3630-304a584c5656","Type":"sas"},{"Id":"EG001200JXLWA","TargetGUID":"452340a5-3047-3130-3230-304a584c5741","Type":"sas"},{"Id":"EG000600JWJNP","TargetGUID":"452340a5-3047-3030-3630-304a574a4e50","Type":"sas"},{"Id":"EG001200JWJNQ","TargetGUID":"452340a5-3047-3130-3230-304a574a4e51","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:43:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>定期的なFWメンテナンスリリース。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>定期的なFWメンテナンスリリース。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"189d6977f8aa4eb9928f0801d69e8b4d"}]},{"ProductId":"9117053fed1245019c94aab3982b0102","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"Lang":"ja","Value":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10およびGen11コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされるバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と機能強化を入手するため、インストールする必要があります。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"783948","DateModified":"2026-02-05T11:55:14","FileList":["./etc/dracut.conf.d/smartpqi.conf","./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"MD5Sum":"6f436a85ad1d85b8d13412b4e0a526be","Name":"smartpqi-kmp-default-2.1.38-022.sles16sp0.x86_64.rpm","Release":"2026-02-05T11:52:24","Revision":"B","SHA1Sum":"e9179ebc8546344d615584aebcdce5a07a436acc","SHA256Sum":"f01d89580fcd15e244e81d4b1aea97cd94401afce8d77177a09e53260dfd0127","Size":"765KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.38-022"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp;--oldpackage --replacefiles --replacepkgs smartpqi-kmp-default-&lt;version&gt;.sles16&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;. If Installation attempted is failed with &ldquo;Failed Dependency&rdquo; Error below Arguments are used to re-try the Installation.</p><ul><li># rpm&nbsp;-Uvh --oldpackage --reinstall&nbsp;smartpqi-kmp-default-&lt;version&gt;.sles16&lt;OSupdate&gt;.x86_64.rpm</li></ul><p>&nbsp;</p><p>Setup is now complete. Please REBOOT your computer NOW!!</p><p>&nbsp;</p><p>&nbsp;</p><p><strong>For SLES16 installations that will be using the Xen Hypervisor, run the following command after&nbsp;installing the driver rpm. This will ensure the updated driver is used for Xen.</strong></p><ul><li>/sbin/update-bootloader --refresh</li></ul><p>&nbsp;</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles16&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp;--oldpackage --replacefiles --replacepkgs smartpqi-kmp-default-&lt;version&gt;.sles16&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;. If Installation attempted is failed with &ldquo;Failed Dependency&rdquo; Error below Arguments are used to re-try the Installation.</p><ul><li># rpm&nbsp;-Uvh --oldpackage --reinstall&nbsp;smartpqi-kmp-default-&lt;version&gt;.sles16&lt;OSupdate&gt;.x86_64.rpm</li></ul><p>&nbsp;</p><p>Setup is now complete. Please REBOOT your computer NOW!!</p><p>&nbsp;</p><p>&nbsp;</p><p><strong>For SLES16 installations that will be using the Xen Hypervisor, run the following command after&nbsp;installing the driver rpm. This will ensure the updated driver is used for Xen.</strong></p><ul><li>/sbin/update-bootloader --refresh</li></ul><p>&nbsp;</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles16&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp;--oldpackage --replacefiles --replacepkgs smartpqi-kmp-default-&lt;version&gt;.sles16&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;. If Installation attempted is failed with &ldquo;Failed Dependency&rdquo; Error below Arguments are used to re-try the Installation.</p><ul><li># rpm&nbsp;-Uvh --oldpackage --reinstall&nbsp;smartpqi-kmp-default-&lt;version&gt;.sles16&lt;OSupdate&gt;.x86_64.rpm</li></ul><p>&nbsp;</p><p>Setup is now complete. Please REBOOT your computer NOW!!</p><p>&nbsp;</p><p>&nbsp;</p><p><strong>For SLES16 installations that will be using the Xen Hypervisor, run the following command after&nbsp;installing the driver rpm. This will ensure the updated driver is used for Xen.</strong></p><ul><li>/sbin/update-bootloader --refresh</li></ul><p>&nbsp;</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles16&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 16 (64-bit)"},{"Lang":"ja","Value":"HPE ProLiant Gen10、Gen10PlusおよびGen11 Smartアレイコントローラー (64ビット) ドライバーfor SUSE LINUX Enterprise Server 16 (64ビット)"},{"Lang":"cn","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 16 (64-bit)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-03-05T11:50:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.38-022"},{"ReleaseNotes":[{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.38-022"}],"SWKeys":[{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3499ad24a1394d098cf83303fba5de87"}]},{"ProductId":"8e8482d9e6e6494a8e54ec40143d190a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"125567","DateModified":"2025-10-14T06:56:13","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"MD5Sum":"08bec676d52d628d2ae46a67197fdc18","Name":"tg3-kmp-default-3.139w_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm","Release":"2025-10-14T06:49:20","Revision":"","SHA1Sum":"30546893097f4bf55778849207c0d8367592980a","SHA256Sum":"5a706701dcc3a73089814e79ef440495d41b4ad70aac15356bc895ab9f441b93","Size":"122KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.139w-2"},{"Bytes":"127424","DateModified":"2025-10-14T07:00:28","FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"MD5Sum":"78c9dbc059d689aecd2755d35618fd13","Name":"tg3-kmp-default-3.139w_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm","Release":"2025-10-14T06:49:20","Revision":"","SHA1Sum":"3d98f8b80e95d3508748614b86ac3a3e3c852591","SHA256Sum":"d4115807d688178f5a07e789de962916070134eabacfcd0e2434205098592ec0","Size":"124KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.139w-2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download README for installation instructions.</p>"},{"Lang":"ja","Value":"<p>インストール手順についてのREADMEをダウンロードします。</p>"},{"Lang":"cn","Value":"<p>Download README for installation instructions.</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T03:19:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes issue where link disconnected with the latest Out-of-Box (OOB) Driver.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、最新の Out-of-Box (OOB) ドライバーでリンクが切断される問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes issue where link disconnected with the latest Out-of-Box (OOB) Driver.</p>","Lang":"cn"}],"Version":"3.139t-2"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"3.139w-2"}],"SWKeys":[{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03030202","Model":"HPE Compute Scale-up Server 3250"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"556f22f571aa44958d24b4b56cbc3bf3"}]},{"ProductId":"4a7391c65f0b46d485ea7105b1cfb339","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A47_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34016718","DateModified":"2026-01-12T20:48:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.00_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.00_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.00_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.00_2026_01_09-1.1/A47_4.00_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.00_2026_01_09-1.1/CP070345.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.00_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.00_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.00_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.00_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070345.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070345.scexe"],"MD5Sum":"f37d9e218213d798c00878066d4676a5","Name":"firmware-system-a47-4.00_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T02:38:14","Revision":"","SHA1Sum":"ca09dd7f3f3ff29f79a5d21bc83dd4f59b2cef1f","SHA256Sum":"fbc385c9267cbe53f041466c011d9f0cf590fa30fdc3f6f45c77108bd455d4af","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:37:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.90_10-03-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"175b14f65a5f4b4691a23aab7aee8a9a"}]},{"ProductId":"ce8ca413963e4458ade3268c0f9831f6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"QLogic driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"QLogicドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"QLogic driver for VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"880161","DateModified":"2025-04-09T09:11:02","FileList":["/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip","/cp066315.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/index.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.4.85.0-1OEM.803.0.0.24022510.vib","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip/vibs/qlnativefc--4967580275396612799.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510.xml"],"MD5Sum":"039b875c214228f28a90f21f5f85834c","Name":"cp066315.zip","Release":"2025-04-09T09:10:01","Revision":"","SHA1Sum":"a5e52b2072e3238f218e3d83a3f4e2b506922803","SHA256Sum":"830fcfc58e810147b4b619ae06b30f7aaf6132d485176115f0e3bdbab8f12eec","Size":"859KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.3"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2025.05.01","VibList":[{"Name":"qlnativefc","Version":"5.4.85.0-1OEM.803.0.0.24022510"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":380,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"},{"Lang":"ja","Value":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li><li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ul><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Update Managerまたはesxcliコマンドを使用します。</li><li>VMware vSphere Update Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ul>"},{"Lang":"cn","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE QLogicファイバーチャネルドライバーコンポーネント for VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T14:54:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.4.83.1<br />This driver is only supported on VMware ESXi&nbsp;8.0u3</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン5.4.83.1<br />このドライバーは、VMware ESXi 8.0u3でのみサポートされています。</p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Driver version 5.4.83.1<br />This driver is only supported on VMware ESXi&nbsp;8.0u3</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2024.09.01"},{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.4.85.0-1<br />This driver is only supported on VMware ESXi&nbsp;8.0u3</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン5.4.85.0-1<br />このドライバーは、VMware ESXi 8.0u3でのみサポートされています。</p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Driver version 5.4.85.0-1<br />This driver is only supported on VMware ESXi&nbsp;8.0u3</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"}],"SWKeys":[{"Name":"qlnativefc:5.4.85.0-1OEM.803.0.0.24022510","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.4.85.0-1OEM.803.0.0.24022510","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e6307a46904e4adc8214e64498f63d2b"},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"QLogic driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"QLogicドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"QLogic driver for VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"871078","DateModified":"2024-06-13T10:07:10","FileList":["/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip","/cp059844.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/index.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.4.82.1-1OEM.800.1.0.20613240.vib","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip/vibs/qlnativefc--6796046031387820499.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240.xml"],"MD5Sum":"b41e66a9fedbe08383ad3409ff55d811","Name":"cp059844.zip","Release":"2024-07-02T00:00:00","Revision":"","SHA1Sum":"6bdc0ea61786a130af041d0b1ea0c0c55ea001cc","SHA256Sum":"91f8bb948d6770c0429d1718363f8624efe96754a8d53f2061a3cad03ad62e70","Size":"850KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2024.03.01","VibList":[{"Name":"qlnativefc","Version":"5.4.82.1-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":380,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"},{"Lang":"ja","Value":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li><li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ul><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Update Managerまたはesxcliコマンドを使用します。</li><li>VMware vSphere Update Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ul>"},{"Lang":"cn","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE QLogicファイバーチャネルドライバーコンポーネント for VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-08-10T13:16:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.4.82.1</p><p>&nbsp;Fixed the DHL customer issue ID SIE276639.</p>","Fixes":"<p>&nbsp;Fixed the DHL customer issue ID SIE276639.</p>","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン5.4.82.1</p><p> DHLのお客様の問題ID SIE276639を修正しました。</p>","Fixes":"<p> DHLのお客様の問題ID SIE276639を修正しました。</p>","Lang":"ja"},{"Enhancements":"<p>Driver version 5.4.82.1</p><p>&nbsp;Fixed the DHL customer issue ID SIE276639.</p>","Fixes":"<p>&nbsp;Fixed the DHL customer issue ID SIE276639.</p>","Lang":"cn"}],"Version":"2024.03.01"},{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.4.82.1</p><p>Fixed an issue where driver logs a 4003 event in ESXi 8.0U2 during server power on, it happens as driver is unable to initialize the adapter due to a &quot;false&quot; checksum.</p>","Fixes":"<p>Fixed an issue where driver logs a 4003 event in ESXi 8.0U2 during server power on, it happens as driver is unable to initialize the adapter due to a &quot;false&quot; checksum.</p>","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン5.4.82.1</p><p>サーバーの電源投入時にESXi 8.0U2でドライバーが4003イベントをログに記録する問題を修正しました。これは、チェックサムが\"false\"であることが原因でドライバーがアダプターを初期化できないために発生します。</p>","Fixes":"<p>サーバーの電源投入時にESXi 8.0U2でドライバーが4003イベントをログに記録する問題を修正しました。これは、チェックサムが\"false\"であることが原因でドライバーがアダプターを初期化できないために発生します。</p>","Lang":"ja"},{"Enhancements":"<p>Driver version 5.4.82.1</p><p>Fixed an issue where driver logs a 4003 event in ESXi 8.0U2 during server power on, it happens as driver is unable to initialize the adapter due to a &quot;false&quot; checksum.</p>","Fixes":"<p>Fixed an issue where driver logs a 4003 event in ESXi 8.0U2 during server power on, it happens as driver is unable to initialize the adapter due to a &quot;false&quot; checksum.</p>","Lang":"cn"}],"Version":"2024.03.01"}],"SWKeys":[{"Name":"qlnativefc:5.4.82.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.4.82.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"8921e49bda05419ca6182da700bed3ce"}]},{"ProductId":"7004592a3bf74fab99a6fe756662ebbc","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />     オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi  - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC、およびMO001920JWWWVドライブ</p><p><strong>リリースバージョンおよび/または日付：</strong><br />     HPDB<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPD9<br /><br /><strong>前のファームウェアバージョン：</strong><br />     HPD9<br /><br /><strong>ファームウェアの関連性：</strong><br />     なし</p><p><strong>機能強化/新しい機能：</strong></p><p>     なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"}],"Files":[{"Bytes":"18045095","DateModified":"2025-03-06T05:05:35","FileList":["/CP065950_BUILD_5.data","/CP065950.vmexe64","/CP065950.vmfile","/CP065950_VMw.zip","/CP065950.xml","/payload.json","/CP065950_VMw.zip/index.xml","/CP065950_VMw.zip/vendor-index.xml","/CP065950_VMw.zip/metadata.zip","/CP065950_VMw.zip/vib20/CP065950/HPE_bootbank_CP065950_HPDB.5-1OEM.800.1.0.20613240.vib","/CP065950_VMw.zip/metadata.zip/vendor-index.xml","/CP065950_VMw.zip/metadata.zip/vmware.xml","/CP065950_VMw.zip/metadata.zip/vibs/CP065950-8875195631491333131.xml","/CP065950_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065950_HPDB.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"6ba4459d7b8d07843da3fef91dfbb464","Name":"CP065950.zip","Release":"2025-03-06T05:04:51","Revision":"C","SHA1Sum":"e506eae6c88f5f129e28beb29f16f9696ebe783c","SHA256Sum":"c4d3963209461f270abb33fab52498b928ed325307e1208f629e00fb1792ba03","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP065950","Version":"HPDB.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040758.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB  Drives"},{"Lang":"ja","Value":"オンライン HDD/SSDフラッシュコンポーネント for VMware ESXi  - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO007680JWTBP","TargetGUID":"562340a5-304f-3730-3638-304a57544250","Type":"sas"},{"Id":"MO006400JWTCD","TargetGUID":"4d2340a5-304f-3630-3430-304a57544344","Type":"sas"},{"Id":"VO003840JWTBN","TargetGUID":"562340a5-304f-3330-3834-304a5754424e","Type":"sas"},{"Id":"MO003200JWTBU","TargetGUID":"4d2340a5-304f-3330-3230-304a57544255","Type":"sas"},{"Id":"EO003200JWTCC","TargetGUID":"452340a5-304f-3330-3230-304a57544343","Type":"sas"},{"Id":"VO001920JWTBL","TargetGUID":"562340a5-304f-3130-3932-304a5754424c","Type":"sas"},{"Id":"MO001600JWTBT","TargetGUID":"4d2340a5-304f-3130-3630-304a57544254","Type":"sas"},{"Id":"EO001600JWTCB","TargetGUID":"452340a5-304f-3130-3630-304a57544342","Type":"sas"},{"Id":"VO000960JWTBK","TargetGUID":"562340a5-304f-3030-3936-304a5754424b","Type":"sas"},{"Id":"MO000800JWTBR","TargetGUID":"4d2340a5-304f-3030-3830-304a57544252","Type":"sas"},{"Id":"EO000800JWTCA","TargetGUID":"452340a5-304f-3030-3830-304a57544341","Type":"sas"},{"Id":"MO000400JWTBQ","TargetGUID":"4d2340a5-304f-3030-3430-304a57544251","Type":"sas"},{"Id":"EO000400JWTBV","TargetGUID":"452340a5-304f-3030-3430-304a57544256","Type":"sas"},{"Id":"MO001920JWWWV","TargetGUID":"4d2340a5-304f-3130-3932-304a57575756","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:36:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5cc55e8f72054302a6d1bd6d2b2ec798"}]},{"ProductId":"64511cd7ad8d42fea109336ca7a083a0","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8002-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8002"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8002-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8002"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8002-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 8.0"},{"Lang":"ja","Value":"このパッケージは、VMware ESXi 8.0上でHPE NVIDIA VPI (EthernetおよびInfinibandモードで動作) ConnectX6アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"}],"Files":[{"Bytes":"30869441","DateModified":"2025-10-14T06:48:50","FileList":["/CP069137.vmexe64","/CP069137.vmfile","/CP069137.xml","/CP069137_VMw.zip","/payload.json","/CP069137_VMw.zip/index.xml","/CP069137_VMw.zip/vendor-index.xml","/CP069137_VMw.zip/metadata.zip","/CP069137_VMw.zip/vib20/CP069137/HPE_bootbank_CP069137_1.0.0-8.0.0.21495797.vib","/CP069137_VMw.zip/metadata.zip/vendor-index.xml","/CP069137_VMw.zip/metadata.zip/vmware.xml","/CP069137_VMw.zip/metadata.zip/vibs/CP069137-1553219289995268396.xml","/CP069137_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069137_1.0.0-8.0.0.21495797.xml"],"MD5Sum":"b51ddbcd3f6cf4316edf360ce5a14fab","Name":"CP069137.zip","Release":"2025-10-14T06:51:49","Revision":"","SHA1Sum":"f264b7c68d843fd2da816e2874ded43b3507e479","SHA256Sum":"7aed0dc4c3c2cda789eb4dbe44265e2fd32a908740dfc9b0dc9c999c38496355","Size":"29MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.9","VibList":[{"Name":"CP069137","Version":"1.0.0-8.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します。 <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 8.0"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ (ESXi 8.0) for HPE NVIDIA  VPI (EthernetおよびInfinibandモード) ConnectX6デバイス - VMware ESXi 8.0"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"13000"},"SupportedDevices":[{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-09T06:35:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが20.43.2566にアップデートされました。</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-HDATアダプター- P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-ECATアダプター- P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe3 x16 MCX653106A-ECATアダプター- P06251-B21</li></ul><p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"1.0.8"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"1.0.9"}],"SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0a78c3c23c29486b936b276fe2c400a5"}]},{"ProductId":"fbe68804b30c4fe28e13ea472cae5392","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWWQUおよびMB006000GWWQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19622651","DateModified":"2025-03-06T07:24:05","FileList":["/CP066006_BUILD_3.data","/CP066006.vmexe64","/CP066006.vmfile","/CP066006_VMw.zip","/CP066006.xml","/payload.json","/CP066006_VMw.zip/index.xml","/CP066006_VMw.zip/vendor-index.xml","/CP066006_VMw.zip/metadata.zip","/CP066006_VMw.zip/vib20/CP066006/HPE_bootbank_CP066006_HPG8.3-1OEM.800.1.0.20613240.vib","/CP066006_VMw.zip/metadata.zip/vendor-index.xml","/CP066006_VMw.zip/metadata.zip/vmware.xml","/CP066006_VMw.zip/metadata.zip/vibs/CP066006--4333994880115514426.xml","/CP066006_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066006_HPG8.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"3dc277d00d0ca5b5da1946c2475ef809","Name":"CP066006.zip","Release":"2025-03-06T07:23:12","Revision":"C","SHA1Sum":"12800bb65c6c697cc923e50cbd221e33fe4d7e74","SHA256Sum":"824bfc9e684fb31c3394952a25269f26d9cfd659e8cc925180195e74f998e993","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8","VibList":[{"Name":"CP066006","Version":"HPG8.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043253.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000GWWQU","TargetGUID":"4d2340a5-3042-3830-3030-304757575155","Type":"sata"},{"Id":"MB006000GWWQT","TargetGUID":"4d2340a5-3042-3630-3030-304757575154","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:05:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cfe31a29a2d64b97b00b6f7494c8b89a"}]},{"ProductId":"942c49f5fada4f3f9198caca6f81e506","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2807852","DateModified":"2025-12-11T08:13:47","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/CP069052.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069052.scexe","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069052.scexe"],"MD5Sum":"0bd4f3d8100ea8db0feddc31d2738f78","Name":"firmware-d8000_0130-1.1_amd64.deb","Release":"2025-12-11T14:05:40","Revision":"A","SHA1Sum":"cd61ccee5fa2d4de172efcb6cb75f0da2f3133f5","SHA256Sum":"ead9f9c2128e7863b7fcc2f3bb71e814fe54f082c2e22b109dcccdb629edcfb9","Size":"2MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"Installation":{"Command":"setup","CommandParams":"-t D8000 -v 0130 -i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff -i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff -l D8000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp;&nbsp;<em>dpkg -i firmware-.....deb -f.&nbsp;</em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp;&nbsp;<em>dpkg -i firmware-.....deb -f.&nbsp;</em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp;&nbsp;<em>dpkg -i firmware-.....deb -f.&nbsp;</em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)"},{"Lang":"ja","Value":"HPE D8000 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Ubuntu (x64)"},{"Lang":"cn","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D8000 12Gb Enclosure","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"},{"Id":"ven_0x1590&dev_0x02db","TargetGUID":"","Type":"pcie"},{"Id":"D8000 12Gb IO","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-06T08:25:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Ubuntu 22.04 LTS</p></li><li><p>Added support of&nbsp;Ubuntu 24.04 LTS.</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Ubuntu 22.04LTSのサポートを追加しました</p></li><li><p>Ubuntu 24.04LTSのサポートを追加しました</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Ubuntu 22.04 LTS</p></li><li><p>Added support of&nbsp;Ubuntu 24.04 LTS.</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275181/20-D8000-Gen10RN0130J_ED11.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"}],"SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d64057659ee048679b20fbd9c6f1638e"}]},{"ProductId":"eafab624995d485096ba1119b617b464","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8559108","DateModified":"2025-07-16T06:12:11","FileList":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/bnx2.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2fc.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2i.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2x.ko","./lib/modules/6.4.0-150600.21-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"MD5Sum":"fd62471aabd475ded5f54b115bcc86f6","Name":"netxtreme2-kmp-default-7.15.25_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-07-16T05:46:00","Revision":"","SHA1Sum":"c8c93c32d32a74b31cfb02070a802f97e67574e7","SHA256Sum":"bd193f0ebd1f8b82ab9853c43b8339a0325fd0d03e38a48b4a38c788222195f8","Size":"8MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"TypeOfChange":"1","Version":"7.15.25-10"},{"Bytes":"8606691","DateModified":"2025-07-16T06:17:27","FileList":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/bnx2.ko","./lib/modules/6.4.0-150700.51-default/updates/bnx2fc.ko","./lib/modules/6.4.0-150700.51-default/updates/bnx2i.ko","./lib/modules/6.4.0-150700.51-default/updates/bnx2x.ko","./lib/modules/6.4.0-150700.51-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"MD5Sum":"4f5bfd3ec4e2347db23b85140f786bab","Name":"netxtreme2-kmp-default-7.15.25_k6.4.0_150700.51-10.sles15sp7.x86_64.rpm","Release":"2025-07-16T05:46:00","Revision":"","SHA1Sum":"0510156659e493aa7d19f653afda4f6b6c5e5cca","SHA256Sum":"ff1ec5064a7a56bc9dd44df793a3d587aee6248933224ff4d9450afaeb4721fd","Size":"8MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"TypeOfChange":"1","Version":"7.15.25-10"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1933","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1933","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"1917","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ad103c1917","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"3382","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c3382","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-16T03:39:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product is updated to maintain compatibility with the latest firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、最新のファームウェアとの互換性を維持してアップデートされています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product is updated to maintain compatibility with the latest firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"7.15.24-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"7.15.25-10"}],"SWKeys":[{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"f16a344479db4e1e843bbe26ae4d1ca7"}]},{"ProductId":"0a4a4367dcbd457bbb50b971046257dd","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされるHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3610およびD3710BディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2372500","DateModified":"2025-12-11T10:15:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-1.1/CP069044.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-1.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-1.1/Reveille-Release-6.00-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-1.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069044.scexe","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069044.scexe"],"MD5Sum":"34b8ffbce51b72b52ac444eb1164ad25","Name":"firmware-d3000_6.00-1.1_amd64.deb","Release":"2025-12-11T16:08:52","Revision":"A","SHA1Sum":"24dedbc4cae934203aabc7db0ab1d211fb77fa3a","SHA256Sum":"dcdc20392c03e2137e44fbf22654e546f80bf9f331912f3563c9b9fc9e519654","Size":"2MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"Installation":{"Command":"setup","CommandParams":"-t D3600B -t D3610B -t D3700B -t D3710B -v 6.00 -i Reveille-Release-6.00-build-000.bin -l D3000B.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp;&nbsp;<em>dpkg -i firmware-.....deb -f.&nbsp;</em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp;&nbsp;<em>dpkg -i firmware-.....deb -f.&nbsp;</em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp;&nbsp;<em>dpkg -i firmware-.....deb -f.&nbsp;</em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)"},{"Lang":"ja","Value":"HPE D3610B/D3710B 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Ubuntu  (x64)"},{"Lang":"cn","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3610B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3710B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-06T08:01:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Ubuntu 22.04 LTS</p></li><li><p>Added support of&nbsp;Ubuntu 24.04 LTS.</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Ubuntu 22.04LTSのサポートを追加しました</p></li><li><p>Ubuntu 24.04LTSのサポートを追加しました</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Ubuntu 22.04 LTS</p></li><li><p>Added support of&nbsp;Ubuntu 24.04 LTS.</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"6.00"}],"SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"dd48ed1fa0f74d52b7aa3f70db3029b3"}]},{"ProductId":"C9113","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Lights-Out Management"},{"Lang":"ja","Value":"ソフトウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"软件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This smart component contains the HPE Lights-Out Online Configuration Utility which is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the operating system without requiring a reboot of the server."},{"Lang":"ja","Value":"このSmartコンポーネントには、サーバーを再起動しないでオペレーティングシステムからProLiant Integrated Lights-Out（iLO）プロセッサーを設定するために使用するコマンドラインユーティリティである、HPE Lights-Outオンライン設定ユーティリティが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1256848","DateModified":"2026-01-12T07:25:16","FileList":["cp070206.xml","cpqsetup.exe","hponcfg.dll","hponcfg.msi"],"MD5Sum":"73ced93007d5f089da366e0d08ea2688","Name":"cp070206.exe","Release":"2026-01-12T07:17:44","Revision":"B","SHA1Sum":"30b92cb52bc7a9403c69ed8760ea367d8a09dd48","SHA256Sum":"192489a2cd5bd00df8d2d09c449d109d5a59d7a262ce8662f6eb338a22aa676e","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6b3a6f74"],"TypeOfChange":"0","Version":"6.0.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":100,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Uninstall any older version of HPONCFG before installing this version of HPONCFG.</p><p>Place Component to a directory in a temporary directory on your hard drive. Double-click it to run.</p><p>Click on the install button to install the utlility on the server. This does not require a reboot.</p><p>&nbsp;</p><p>&nbsp;</p><p>The utility will be installed in the program files under the directory HewlettPackardEnterprise\\HPONCFG\\</p><p>&nbsp;</p><p>&nbsp;</p><p>A shortcut for the graphical interface of the utility will be provided in &quot;Start Menu &gt; Programs &gt; HPE System Tools &gt; HPE Lights-Out Online Configuration Utility&quot;.</p>"},{"Lang":"ja","Value":"<p>HPONCFGのこのバージョンをインストールする前に、HPONCFGのすべての古いバージョンをアンインストールします。</p><p>コンポーネントを、ご使用のハードドライブの一時ディレクトリ内のディレクトリに置きます。ダブルクリックして実行します。</p><p>インストールボタンをクリックし、サーバーにユーティリティをインストールします。再起動は必要ありません。</p><p> </p><p> </p><p>ユーティリティは、HewlettPackardEnterprise\\HPONCFG\\ディレクトリの下にあるprogram filesにインストールされます</p><p> </p><p> </p><p>ユーティリティのグラフィカルインターフェイス用のショートカットが、スタートメニュー >プログラム > HPEシステムツール > HPE Lights-Outオンライン構成ユーティリティに提供されます。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Lights-Out Online Configuration Utility for Windows x64 Editions"},{"Lang":"ja","Value":"HPE Lights-Out オンライン構成ユーティリティfor Windows x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"160"},"SupportedDevices":[{"Dev":"B204","SubDev":"B206","SubVen":"0E11","TargetGUID":"a6b1a447-382a-5a4f-0e11-b2040e11b206","Type":"pci","Ven":"0E11"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Id":"5219994","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3306103c3381","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3307103c3381","Type":"pci","Ven":"103C"},{"Dev":"3308","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3308103c3381","Type":"pci","Ven":"103C"},{"Dev":"3300","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3300103c3381","Type":"pci","Ven":"103C"},{"Dev":"3301","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3301103c3381","Type":"pci","Ven":"103C"},{"Dev":"3302","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3302103c3381","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103c"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012","Platform":"nt_x86-64","Sr":"OEM"},{"Edition":"Essentials","Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012 Essentials","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T13:19:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for Windows 2025</p>","Fixes":"<p>None.</p>","Lang":"en"},{"Enhancements":"<p>Windows Server 2025のサポートを追加しました</p>","Fixes":"<p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added support for Windows 2025</p>","Fixes":"<p>None.</p>","Lang":"cn"}],"Version":"6.0.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>Added support for Windows 2025</p>","Fixes":"<p>None.</p>","Lang":"en"},{"Enhancements":"<p>Windows Server 2025のサポートを追加しました</p>","Fixes":"<p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added support for Windows 2025</p>","Fixes":"<p>None.</p>","Lang":"cn"}],"Version":"6.0.0.0"}],"SWKeys":[{"Name":"hponcfg.exe","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\HPONCFG"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I38","Model":"HPE ProLiant BL660c Gen9 Server"},{"Family":"I32","Model":"HP ProLiant BL660c Gen8 Server"},{"Family":"A26","Model":"HP ProLiant BL465c Gen8 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant BL460c Gen9 Server"},{"Family":"I31","Model":"HP ProLiant BL460c Gen8 Server"},{"Family":"I30","Model":"HP ProLiant BL420c Gen8 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P79","Model":"HP ProLiant DL580 Gen8 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P77","Model":"HP ProLiant DL560 Gen8 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A28","Model":"HP ProLiant DL385p Gen8 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P70","Model":"HP ProLiant DL380p Gen8 Server"},{"Family":"P73","Model":"HP ProLiant DL380e Gen8 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"P71","Model":"HP ProLiant DL360p Gen8 Server"},{"Family":"P73","Model":"HP ProLiant DL360e Gen8 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"P80","Model":"HP ProLiant DL320e Gen8 v2 Server"},{"Family":"J05","Model":"HP ProLiant DL320e Gen8 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"J03","Model":"HP ProLiant DL160 Gen8 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P72","Model":"HP ProLiant ML350p Gen8 Server"},{"Family":"J02","Model":"HP ProLiant ML350e Gen8 Server"},{"Family":"P78","Model":"HP ProLiant ML310e Gen8 v2 Server"},{"Family":"J04","Model":"HP ProLiant ML310e Gen8 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"P88","Model":"HP ProLiant ML10 Server"},{"Family":"P74","Model":"HP ProLiant SL4540 Gen8 3 Node Server"},{"Family":"P75","Model":"HP ProLiant SL270s Gen8 Server"},{"Family":"P75","Model":"HP ProLiant SL270s Gen8 SE Server"},{"Family":"P75","Model":"HP ProLiant SL250s Gen8 Server"},{"Family":"P75","Model":"HP ProLiant SL230s Gen8 Server"},{"Family":"P83","Model":"HP ProLiant SL210t Gen8 Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"P94","Model":"HP ProLiant XL220a Gen8 v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL215n Gen10 Plus"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"J06","Model":"HP ProLiant MicroServer Gen8"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"I36","Model":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"Family":"I31","Model":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"R11","Model":"HPE ProLiant RL300 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"I15","Model":"HP ProLiant BL460c Server"},{"Family":"P64","Model":"HP ProLiant DL360 G6 Server"},{"Family":"W04","Model":"HP ProLiant DL320s Storage Server"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HP StorageWorks 1200 All-in-One Storage System"},{"Family":"","Model":"HP StorageWorks 600 All-in-One Storage System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2e68cf7c5c944e8dac3a1c14e1da06af"}]},{"ProductId":"e99fcbdfe7054c0191086c267b0b5462","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U61_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.52 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17138622","DateModified":"2026-01-13T02:15:04","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.52_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.52_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.52_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.52_2026_01_09-1.1/CP070164.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.52_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.52_2026_01_09-1.1/U61_2.52_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.52_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.52_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.52_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070164.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070164.scexe"],"MD5Sum":"2e6aa4da8cce017a6cb17f4812473afb","Name":"firmware-system-u61-2.52_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T08:05:50","Revision":"","SHA1Sum":"6f367f3377a3603279c9f6694bc1da0aae29f3a5","SHA256Sum":"b808e43620387f9ee39d1311bf2b528fda47e0bd923fc243f318a1abc32601d7","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.52_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML30 Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T06:10:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.708（2.50_07_25_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_01-09-2026"}],"SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"153a48461ec44b26b13c172bef259525"}]},{"ProductId":"8ae644bee0c14cc0b7aad5521f061ad1","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.35.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under Windows Server 2022, and Windows Server 2025 Only."},{"Lang":"ja","Value":"このパッケージには、Windows Server 2022およびWindows Server 2025のみで動作するHPE ProLiant Gen10サーバーシリーズのBroadcom NX1 Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8428824","DateModified":"2025-11-17T02:27:20","FileList":["bcmnicfwupg.exe","BMAPIa.dll","cp069007.xml","cpqsetup.exe","FW/","FW/330i-2x1G-14E4-1665-103C-22BD.BIN","FW/331FLR-4x1G-14E4-1657-103C-169D.BIN","FW/331i-4x1G-14E4-1657-103C-22BE.BIN","FW/331T-4x1G-14E4-1657-103C-3383.BIN","FW/332i-2x1G-14E4-165F-103C-22E8.BIN","FW/332T-2x1G-14E4-165F-103C-1786.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"de1b889493a054338ca69a52bacda140","Name":"cp069007.exe","Release":"2025-11-17T02:18:30","Revision":"","SHA1Sum":"aa361bc0bf078db0577552610c8dbcf3f3248db8","SHA256Sum":"76453e05076395aed4b1606245e22a93c2321de0dd3f5d8902fde6407340da53","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"5.4.6.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 1Gb Driver is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","SWKey":"b57nd60a.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。 </li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility Windows Server x64 Editions for HPE ProLiant Gen10 server series Only"},{"Lang":"ja","Value":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティfor Windows Server x64 Editions（HPE ProLiant Gen10サーバーシリーズ専用）。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T05:39:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"5.4.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during &nbsp;Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during &nbsp;Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during &nbsp;Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed</li></ul>","Lang":"cn"}],"Version":"5.4.6.0"}],"SWKeys":[{"Name":"BcmNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"6f3942ddb3bd4a8da61bc722e1858496"}]},{"ProductId":"66a1346762c14adc98a81649c4277c93","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、MB018000GYDKR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19665375","DateModified":"2025-07-09T13:26:47","FileList":["/CP067769_BUILD_1.data","/CP067769.vmexe64","/CP067769.vmfile","/CP067769_VMw.zip","/CP067769.xml","/payload.json","/CP067769_VMw.zip/index.xml","/CP067769_VMw.zip/vendor-index.xml","/CP067769_VMw.zip/metadata.zip","/CP067769_VMw.zip/vib20/CP067769/HPE_bootbank_CP067769_HPG3.1-8.0.0.20613240.vib","/CP067769_VMw.zip/metadata.zip/vendor-index.xml","/CP067769_VMw.zip/metadata.zip/vmware.xml","/CP067769_VMw.zip/metadata.zip/vibs/CP067769--2947320039690888302.xml","/CP067769_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067769_HPG3.1-8.0.0.20613240.xml"],"MD5Sum":"65f1be87218792bc577d89cedcb19d3e","Name":"CP067769.zip","Release":"2025-07-09T13:25:55","Revision":"C","SHA1Sum":"ec3e9b9242dac229b80269d7b6547de400037708","SHA256Sum":"687c0d908af1b7062da6eab02bab1f546c9442e7897839ebfde7c3498ceb040b","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP067769","Version":"HPG3.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、およびMB018000GYDKRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB010000GYDKP","TargetGUID":"4d2340a5-3042-3031-3030-304759444b50","Type":"sata"},{"Id":"MB016000GYDKQ","TargetGUID":"4d2340a5-3042-3631-3030-304759444b51","Type":"sata"},{"Id":"MB018000GYDKR","TargetGUID":"4d2340a5-3042-3831-3030-304759444b52","Type":"sata"},{"Id":"MB012000GYCJL","TargetGUID":"4d2340a5-3042-3231-3030-304759434a4c","Type":"sata"},{"Id":"MB014000GYCJT","TargetGUID":"4d2340a5-3042-3431-3030-304759434a54","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-08T05:49:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"331ca58137bc41668767a713b6e50f2c"}]},{"ProductId":"308794285e444711a0eb3833d54eb10e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000600JWCPFおよびEH000900JWCPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"4121264","DateModified":"2025-11-17T14:24:13","FileList":["cp068657.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SKESTEDD.rel"],"MD5Sum":"cb997288baa51f2584cc42106a02061c","Name":"cp068657.exe","Release":"2025-11-17T14:18:57","Revision":"C","SHA1Sum":"b6b07de380f82f0c822493a1fab3e60ba2c5a826","SHA256Sum":"5174318587325cc3f333e1fbc5a0275c40cd1ec18b1d26a04a7e1594fd96c943","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EH000600JWCPF","TargetGUID":"452340a5-3048-3030-3630-304a57435046","Type":"sas"},{"Id":"EH000900JWCPH","TargetGUID":"452340a5-3048-3030-3930-304a57435048","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:47:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDD"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDD"}],"SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"abfd69e9a7e643a8a89639344b52127e"}]},{"ProductId":"f61d4171b71b4f16a99210ceeba911f6","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされるHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3610およびD3710BディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8321521","DateModified":"2025-12-19T12:00:23","FileList":["/CP069043_BUILD_3.data","/CP069043.vmcfg","/CP069043.vmexe64","/CP069043.vmfile","/CP069043_VMw.zip","/CP069043.xml","/payload.json","/CP069043_VMw.zip/index.xml","/CP069043_VMw.zip/vendor-index.xml","/CP069043_VMw.zip/metadata.zip","/CP069043_VMw.zip/vib20/CP069043/HPE_bootbank_CP069043_6.00.3-8.0.0.20613240.vib","/CP069043_VMw.zip/metadata.zip/vendor-index.xml","/CP069043_VMw.zip/metadata.zip/vmware.xml","/CP069043_VMw.zip/metadata.zip/vibs/CP069043--7460497353391337424.xml","/CP069043_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069043_6.00.3-8.0.0.20613240.xml"],"MD5Sum":"7a4465e42b597a64b9b0b9a738165f7b","Name":"CP069043.zip","Release":"2025-12-19T11:57:14","Revision":"H","SHA1Sum":"bacf4c81ffafa5056c796e22875d24944975ea59","SHA256Sum":"e53ae87c2799302394e726cc64687d3ea0398a29a288ef0b1488d535c3e17a29","Size":"7MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00","VibList":[{"Name":"CP069043","Version":"6.00.3-8.0.0.20613240"}]}],"Installation":{"Command":"setup","CommandParams":"-t D3600B -t D3610B -t D3700B -t D3710B -v 6.00 -i Reveille-Release-6.00-build-000.bin -l D3000B.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"ja","Value":"HPE D3610B/D3710B 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"},{"Lang":"cn","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3610B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3710B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-06T07:40:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p>ESXi 9.0のサポートを追加しました</p><p>ESXi 7.0のサポートを削除しました</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275183/20-D3000B-Gen10RN600I_ED10.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"6.00"}],"SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bcabba34074641b793c48a6fb84d7bba"}]},{"ProductId":"b6cb1e645c374b3e92e6a0688121990e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"},{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"18081286","DateModified":"2025-06-14T08:40:07","FileList":["/CP067556_BUILD_1.data","/CP067556.vmexe64","/CP067556.vmfile","/CP067556_VMw.zip","/CP067556.xml","/payload.json","/CP067556_VMw.zip/index.xml","/CP067556_VMw.zip/vendor-index.xml","/CP067556_VMw.zip/metadata.zip","/CP067556_VMw.zip/vib20/CP067556/HPE_bootbank_CP067556_HPD6.1-8.0.0.20613240.vib","/CP067556_VMw.zip/metadata.zip/vendor-index.xml","/CP067556_VMw.zip/metadata.zip/vmware.xml","/CP067556_VMw.zip/metadata.zip/vibs/CP067556--7130822363036220197.xml","/CP067556_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067556_HPD6.1-8.0.0.20613240.xml"],"MD5Sum":"0e3807916ed6b0a337f499d8439a6e25","Name":"CP067556.zip","Release":"2025-06-14T08:39:17","Revision":"E","SHA1Sum":"d34707ba28b82986fe49cb86fba11f42a54bfdf6","SHA256Sum":"da65bf92db8dab517689f912b8e91831ecfea39cc618d717b1b1e3a7ff38270d","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3330-304a57534a50"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP067556","Version":"HPD6.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP041563.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EG001200JWJNK","TargetGUID":"452340a5-3047-3130-3230-304a574a4e4b","Type":"sas"},{"Id":"EG000600JWJNH","TargetGUID":"452340a5-3047-3030-3630-304a574a4e48","Type":"sas"},{"Id":"EG000300JWSJP","TargetGUID":"452340a5-3047-3030-3330-304a57534a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-11T19:01:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1069d25103ac4267bfca3899f62f706e"}]},{"ProductId":"b9dda486435f4c78a30de5b1c831c135","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides HPE Apollo 4200 Gen10Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 4200 Gen10Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides HPE Apollo 4200 Gen10Plus Backplane Expander Firmware"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3768816","DateModified":"2025-11-14T02:40:13","FileList":["cp067915.xml","cpqsetup.exe","Eaglescanyon-Release-0.39.bin.fw","payload.json","setup.dll"],"MD5Sum":"0f3433186d2567908c8dca428afa7ba7","Name":"cp067915.exe","Release":"2025-11-14T02:34:08","Revision":"F","SHA1Sum":"ef4a193202048ddf8f25326f5bb64b7fcd538b64","SHA256Sum":"1820502b3a39c81c96869cea71b2e8dbb3d45a7035597de3356cb1c5c85605ae","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p><ul><li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows (x64) - HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーファームウェア"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-23T06:21:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support&nbsp;Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support&nbsp;Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support&nbsp;Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"0.39"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"0.39"}],"SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f1cd8f46c3014c16bdd1409b73d30b12"}]},{"ProductId":"4106b2f5d7c1411c95e94d52dff63df7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM1000GFJTE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MM1000GFJTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br /><br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br /><br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3804936","DateModified":"2025-11-17T07:06:20","FileList":["cp068661.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SAVGNTG6.rel","setup.dll"],"MD5Sum":"05ca56b1c891499ada008dec8b079141","Name":"cp068661.exe","Release":"2025-11-17T07:01:05","Revision":"E","SHA1Sum":"076ca4bb7387b6ea22a4beabbeebe5b80f4736fc","SHA256Sum":"c1c033ff4b09a74896664e480b715d9d1bae5f91fdcd9da2bc4388026275c778","Size":"3MB","TargetGUIDs":["002340a5-4d00-314d-3030-3047464a5445"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000GFJTEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MM1000GFJTE","TargetGUID":"002340a5-4d00-314d-3030-3047464a5445","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:56:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MM1000GFJTE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"47d3648625a244c6b991f4dbff7a42fe"}]},{"ProductId":"cf36f8009ed4464f93a208bf9c35b47b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"797820","DateModified":"2025-11-18T07:55:29","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"MD5Sum":"c0682a3fe1a34cb50cb53ebeca53b816","Name":"elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-11-18T07:51:04","Revision":"","SHA1Sum":"607df852c182ac6a9aa8965ede09cf15a20a4d03","SHA256Sum":"737d9fdeb0e4212b9dd46b1aafc608cbc4b8daa23376b575762c7b83ef1b5398","Size":"779KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.731.6"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.589.5_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.589.5_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.589.5_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"ja","Value":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-26T05:10:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10.0</p><p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.731.6"}],"SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"cbb0141049c34b0faa1d65ddc5452cec"}]},{"ProductId":"8f24173ef2e740d2b110bb710e861366","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. "},{"Lang":"ja","Value":"HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"32340410","DateModified":"2025-09-19T08:32:46","FileList":["./etc/init.d/LsiSASH","./opt/HPEMRSA/LSIStorageAuthority","./opt/HPEMRSA/LSIStorageAuthority/bin","./opt/HPEMRSA/LSIStorageAuthority/bin/LSA","./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so.4","./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib8.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so","./opt/HPEMRSA/LSIStorageAuthority/bin/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer","./opt/HPEMRSA/LSIStorageAuthority/bin/storelib8conf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconfit.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/temp","./opt/HPEMRSA/LSIStorageAuthority/conf","./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf","./opt/HPEMRSA/LSIStorageAuthority/conf/languages","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr8_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_errors_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode8.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs","./opt/HPEMRSA/LSIStorageAuthority/logs","./opt/HPEMRSA/LSIStorageAuthority/plugins","./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/report","./opt/HPEMRSA/LSIStorageAuthority/server","./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win","./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types","./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/docs","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru","./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/README","./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/html","./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-Chg-Personality.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure1-InstallShieldWizardDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure2-PortConfigurationSettingsDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure3-DestinationFolderDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure4-ConfigureRangeOfEventsToGenerateAlertNotifications.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_NVMe_Thermal_Poll_Interval.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_alert_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_writecache_policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_changing_behavior_modes.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ChangeDrive-Security.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure21-EnableTheUnmapFeatureDuringVolumeCreation.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ManagePCIe-Storage-Interface2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/Replace-a-Missing-Drive.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/config-login-no-login-localhost-remote-access.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-lsa-spin-down.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-spin-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-hpe-nvram-clear.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-nvme-thermal-poll-interval.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v10550932.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036741.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036763.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036906.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11169464.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049673.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049745.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12382402.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13111710.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13292421.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v26717125.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v8285855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9157473.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9506612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9508081.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery-1.4.2.1-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery.flexslider-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery_page_top_arrow.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/1370F7A6BA15F932ABC2CD3083B97DDD.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/D27EEE45B074A44BC7BEE885A75C289C.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/FBEEC26C1FC5A6C6CE967B685C48BB53.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/A651E792C5B1FFE8C7A2FF01DBDA7D28.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/13517E860F6874F70EDF25750E13016A.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/ACC3F85EC285012679DBC35184BE5E5E.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/logs","./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log","./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log","./opt/HPEMRSA/LSIStorageAuthority/server/nginx","./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/start.log","./opt/HPEMRSA/LSIStorageAuthority/server/temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9","./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh","./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/15d40c719d4feaf19bbe61ce2da66bd5739c3d","./usr/lib/.build-id/08/b8352d861c6619aac9f7b7e9015da9d8945e09","./usr/lib/.build-id/0e","./usr/lib/.build-id/0e/f3db1217fc5acb1f86191133fe9cec97205859","./usr/lib/.build-id/13","./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6","./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6.1","./usr/lib/.build-id/17","./usr/lib/.build-id/17/485063472e0bebe1817427684593ae91124c06","./usr/lib/.build-id/27","./usr/lib/.build-id/27/b31992b09f650c906ee209359448d9cd1edfdd","./usr/lib/.build-id/44","./usr/lib/.build-id/44/0e9c8f0a2f53742fc89111ffc5a0477c44c8be","./usr/lib/.build-id/49","./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623","./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623.1","./usr/lib/.build-id/59","./usr/lib/.build-id/59/375a2f8295fd816a67e5574b3fe5976bee073a","./usr/lib/.build-id/63","./usr/lib/.build-id/63/0e2a1514627242890b188e7c97e53dade7dec0","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f","./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f.1","./usr/lib/.build-id/82","./usr/lib/.build-id/82/6e24fcdbe0a8f810b6a58cef4e95fc6161bfd4","./usr/lib/.build-id/85","./usr/lib/.build-id/85/95f1c93754946a6f51f77557bc2efc250accae","./usr/lib/.build-id/85/95f1c93754946a6f51f77557bc2efc250accae.1","./usr/lib/.build-id/89","./usr/lib/.build-id/89/4cfc4e2d609fda9f4040a5289ce7e879b190c2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd","./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd.1","./usr/lib/.build-id/a0","./usr/lib/.build-id/a0/e9da989ba67ae6c01701ffb71e464dfd0801a1","./usr/lib/.build-id/c4","./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a","./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a.1","./usr/lib/.build-id/da","./usr/lib/.build-id/da/148365b4598445ed303ccd1d13d1fe3f342d23","./usr/lib/.build-id/db","./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157","./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157.1","./usr/lib/.build-id/df","./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986","./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986.1","./usr/lib/.build-id/e6","./usr/lib/.build-id/e6/14c16894270f516cb00291b96cdb3991a2499d","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce","./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce.1","./usr/share/smartupdate/MRStorageAdministrator/component.xml"],"MD5Sum":"f380e39de91212dedb1843175051bc06","Name":"MRStorageAdministrator-008.012.052.000-00.x86_64.rpm","Release":"2025-09-19T08:29:38","Revision":"B","SHA1Sum":"508d2f2ec446bd89e0871070618e3f0aff3f5e9a","SHA256Sum":"c8955c0421874901d405d50e16a3a06393b3fafcd4cd14e822795b606fb81f26","Size":"30MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"TypeOfChange":"1","Version":"8.12.52.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li><li>Use &quot;rpm&nbsp;-Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li><li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li></ul>"},{"Lang":"ja","Value":"<ul><li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li><li>Use &quot;rpm&nbsp;-Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li><li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li></ul>"},{"Lang":"cn","Value":"<ul><li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li><li>Use &quot;rpm&nbsp;-Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li><li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator for RHEL9, SLES15 and SLES16 (HPE MRSA for Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator for RHEL9, SLES15 and SLES16 (HPE MRSA for Gen10P and Gen11 Controllers)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator for RHEL9, SLES15 and SLES16 (HPE MRSA for Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-19T06:10:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Change the backplane bay count information to the actual bay that is connected to controller.</li><li>Add support for users to clear NVRAM using Factory Repurpose operation</li><li>Re-order LSA GUI buttons<ul><li>Move the Rebuild button to the top before Make Online button</li><li>Add the Rebuild button in the Offline Drive warning session</li></ul></li><li>Change the recommended action for Degarded Volume to &ldquo;Make sure all the&nbsp;participating drives are connected and rebuild is complete&rdquo;.</li></ul>","Fixes":"<ul><li>Fix MRSA issue in a00150411en_us Advisory: HPE Compute MR Controllers - HPE MR Storage Administrator (MRSA) Launch Issue and Storage Command Line Interface&nbsp;(StorCLI) Installation Warning Message Observed With Red Hat Enterprise Linux Server&nbsp;10</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Change the backplane bay count information to the actual bay that is connected to controller.</li><li>Add support for users to clear NVRAM using Factory Repurpose operation</li><li>Re-order LSA GUI buttons<ul><li>Move the Rebuild button to the top before Make Online button</li><li>Add the Rebuild button in the Offline Drive warning session</li></ul></li><li>Change the recommended action for Degarded Volume to &ldquo;Make sure all the&nbsp;participating drives are connected and rebuild is complete&rdquo;.</li></ul>","Fixes":"<ul><li>Fix MRSA issue in a00150411en_us Advisory: HPE Compute MR Controllers - HPE MR Storage Administrator (MRSA) Launch Issue and Storage Command Line Interface&nbsp;(StorCLI) Installation Warning Message Observed With Red Hat Enterprise Linux Server&nbsp;10</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Change the backplane bay count information to the actual bay that is connected to controller.</li><li>Add support for users to clear NVRAM using Factory Repurpose operation</li><li>Re-order LSA GUI buttons<ul><li>Move the Rebuild button to the top before Make Online button</li><li>Add the Rebuild button in the Offline Drive warning session</li></ul></li><li>Change the recommended action for Degarded Volume to &ldquo;Make sure all the&nbsp;participating drives are connected and rebuild is complete&rdquo;.</li></ul>","Fixes":"<ul><li>Fix MRSA issue in a00150411en_us Advisory: HPE Compute MR Controllers - HPE MR Storage Administrator (MRSA) Launch Issue and Storage Command Line Interface&nbsp;(StorCLI) Installation Warning Message Observed With Red Hat Enterprise Linux Server&nbsp;10</li></ul>","Lang":"cn"}],"Version":"8.12.52.0"},{"ReleaseNotes":[{"Enhancements":"<p>For NovSPP2025</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>For NovSPP2025</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>For NovSPP2025</p>","Fixes":"","Lang":"cn"}],"Version":"8.12.52.0"}],"SWKeys":[{"Name":"MRStorageAdministrator","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fc77eeea8c99495787299504a02b364f"}]},{"ProductId":"cd1eb2802ed24b6aa04d98effb166b0e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19594530","DateModified":"2025-07-04T04:39:25","FileList":["/CP067698_BUILD_1.data","/CP067698.vmexe64","/CP067698.vmfile","/CP067698_VMw.zip","/CP067698.xml","/payload.json","/CP067698_VMw.zip/index.xml","/CP067698_VMw.zip/vendor-index.xml","/CP067698_VMw.zip/metadata.zip","/CP067698_VMw.zip/vib20/CP067698/HPE_bootbank_CP067698_HPD5.1-8.0.0.20613240.vib","/CP067698_VMw.zip/metadata.zip/vendor-index.xml","/CP067698_VMw.zip/metadata.zip/vmware.xml","/CP067698_VMw.zip/metadata.zip/vibs/CP067698--3467908086726286014.xml","/CP067698_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067698_HPD5.1-8.0.0.20613240.xml"],"MD5Sum":"7758f1bd434d8fb1001fe36027ad1d2a","Name":"CP067698.zip","Release":"2025-07-04T04:38:29","Revision":"B","SHA1Sum":"d271de619a1752a9ead63dd5b11953b499d1b506","SHA256Sum":"ea8dd8ea697efeefd6e590e34d1b316c1b8a8fe93c84d566b1a096bc243968dc","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP067698","Version":"HPD5.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP042550.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EO000800PXDCK","TargetGUID":"452340a5-304f-3030-3830-30505844434b","Type":"sas"},{"Id":"MO000800PXDBP","TargetGUID":"4d2340a5-304f-3030-3830-305058444250","Type":"sas"},{"Id":"EO000400PXDBQ","TargetGUID":"452340a5-304f-3030-3430-305058444251","Type":"sas"},{"Id":"EO001600PXDCH","TargetGUID":"452340a5-304f-3130-3630-305058444348","Type":"sas"},{"Id":"MO001600PXDCC","TargetGUID":"4d2340a5-304f-3130-3630-305058444343","Type":"sas"},{"Id":"MO006400PXDCE","TargetGUID":"4d2340a5-304f-3630-3430-305058444345","Type":"sas"},{"Id":"VO007680PXDBU","TargetGUID":"562340a5-304f-3730-3638-305058444255","Type":"sas"},{"Id":"VO001920PXDBR","TargetGUID":"562340a5-304f-3130-3932-305058444252","Type":"sas"},{"Id":"VO015300PXDBV","TargetGUID":"562340a5-304f-3531-3330-305058444256","Type":"sas"},{"Id":"MO003200PXDCD","TargetGUID":"4d2340a5-304f-3330-3230-305058444344","Type":"sas"},{"Id":"VO000960PXDBN","TargetGUID":"562340a5-304f-3030-3936-30505844424e","Type":"sas"},{"Id":"VO003840PXDBT","TargetGUID":"562340a5-304f-3330-3834-305058444254","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-01T12:44:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e007d4995120489984d46b3e44e87a5d"}]},{"ProductId":"f4d3c3f0b12d4c1da09c3d11188e06cf","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQ"},{"Lang":"cn","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul><p><strong>Known Issues:</strong></p><p>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul><p><strong>Known Issues:</strong></p><p>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul><p><strong>Known Issues:</strong></p><p>None</p>"}],"Files":[{"Bytes":"7707407","DateModified":"2025-09-21T20:12:39","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/85032G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/CP068910.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068910.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068910.scexe"],"MD5Sum":"f608bcae3db53aea0df5cd98278efb95","Name":"firmware-hdd-805abb7e9c-85032G00-13.1.x86_64.rpm","Release":"2025-09-22T00:59:59","Revision":"M","SHA1Sum":"8f1571bfeda95b7a465d39e22ca1b98047b22d50","SHA256Sum":"706d9b4aa33867604d31011fc21bacccdec0223524925883b7fd3a56be01fe38","Size":"7MB","TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00"}],"Installation":{"Command":"CP042967.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VS003840KWXFQ","TargetGUID":"562340a5-3053-3330-3834-304b57584651","Type":"nvme"},{"Id":"VS001920KWXFP","TargetGUID":"562340a5-3053-3130-3932-304b57584650","Type":"nvme"},{"Id":"VS000960KWXFN","TargetGUID":"562340a5-3053-3030-3936-304b5758464e","Type":"nvme"},{"Id":"VS000480KXALB","TargetGUID":"562340a5-3053-3030-3438-304b58414c42","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:50:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"85032G00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul>","Lang":"cn"}],"Version":"85032G00"}],"SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"25502ba383f94660b9ac0d565f894d75"}]},{"ProductId":"c046b36cf8a0464e9240313acab20b06","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp068057.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2446343","DateModified":"2025-08-03T23:00:25","FileList":["./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1/CP068059.xml","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1/cp068057.compsig","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1/cp068057.zip","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068059.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068059.scexe"],"MD5Sum":"4211527b51f83ec71d34c69af06201f4","Name":"firmware-microserverv2gen10plus_me-06.00.03.708-1.1.x86_64.rpm","Release":"2025-08-04T03:53:23","Revision":"","SHA1Sum":"e9f57cfc5fe6b059b4ebb9611bb4f00dd317f3b9","SHA256Sum":"ab873876296c1b23fcf47f4bed5964d7911707b17266ff4ca7a327861c80fdc3","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2"},{"Lang":"ja","Value":"オンラインROMフラッシュ for Linux - Server Platform Services (SPS)ファームウェア for HPE ProLiant MicroServer Gen10 Plus v2"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-09-04T03:31:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.700 (2.30_01_07_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"06.00.03.708"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b1a50f66e8d2407b83819179781ca5ac"}]},{"ProductId":"7be91d25e6cd4a81ae4d61a4439a88bc","Versions":[{"DeviceClass":"42fc70be-bb87-4bdb-8e7c-db1c9af52957","Devices":{"Device":[{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.0.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000242","Version":"2.0.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.0.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"2.0.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.0.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000221","Version":"2.0.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Management"},{"Lang":"ja","Value":"ファームウェア - マネジメント"},{"Lang":"cn","Value":"固件 - 管理"}],"Description":[{"Lang":"en","Value":"This component updates HPE Edgeline Chassis Controller Firmware"},{"Lang":"ja","Value":"このコンポーネントはHPE Edgelineシャーシコントローラーファームウェアをアップデートします"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"434854","DateModified":"2025-10-07T10:02:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-acce-2.0.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-acce-2.0.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-acce-2.0.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-acce-2.0.0-1.1/ACCE_2.0.0s.bin","./usr/lib/x86_64-linux-gnu/firmware-acce-2.0.0-1.1/CP069107.xml","./usr/lib/x86_64-linux-gnu/firmware-acce-2.0.0-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-acce-2.0.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-acce-2.0.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-acce-2.0.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069107.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069107.scexe"],"MD5Sum":"c6fd1d4f96c6b22fc2b49ab1fd3f25ea","Name":"firmware-acce-2.0.0-1.1.x86_64.rpm","Release":"2025-10-07T14:54:07","Revision":"C","SHA1Sum":"033784e7994ddf128939682a82bb7bee52e97226","SHA256Sum":"15fab2f84c7a0e13ebc0d99a44bb0939d85a4376ddfe165e4bd6540e6b67e11c","Size":"424KB","TargetGUIDs":["00000000-0000-0000-0000-000000000242","00000000-0000-0000-0000-00000000023a","00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"2.0.0"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm</p><p>Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup &ndash;s &ndash;f&rsquo; at the command prompt&rdquo;.</p><p>iLO reset is required after firmware update to display the current firmware version in iLO GUI.</p><p>&nbsp;</p><p>&nbsp;</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm</p><p>前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup –s –f’とタイプしてhpsetupを実行します。</p><p>現在のファームウェアバージョンをiLO GUIに表示するには、ファームウェアアップデート後にiLOをリセットする必要があります。</p><p> </p><p> </p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - HPE Edgeline Chassis Controller Firmware"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - HPE Edgelineシャーシコントローラーファームウェア"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-07T14:46:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>SHA384 fix</p>","Fixes":"<ul><li>Signed with SHA384</li></ul>","Lang":"en"},{"Enhancements":"<p>SHA384 fix</p>","Fixes":"<ul><li>Signed with SHA384</li></ul>","Lang":"ja"},{"Enhancements":"<p>SHA384 fix</p>","Fixes":"<ul><li>Signed with SHA384</li></ul>","Lang":"cn"}],"Version":"1.5.10"},{"ReleaseNotes":[{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"cn"}],"Version":"2.0.0"}],"SWKeys":[{"Name":"ACCE","SWKeyExpectedPath":"firmware:sd:ACC"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"FTP","Model":"FTP-Only System"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"H11","Model":"HPE ProLiant EL8000s"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2e62e2b243d94aab8c80c1741ef86cca"}]},{"ProductId":"a2d50341a55d404a82473ce007636a93","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"13775658","DateModified":"2025-12-11T09:02:23","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/CP070012.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-12.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070012.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070012.scexe"],"MD5Sum":"5b85f317b385ddf602a9927284c6a055","Name":"firmware-d8000-0130-12.1.x86_64.rpm","Release":"2025-12-11T14:51:04","Revision":"L","SHA1Sum":"53ca785fef510d47dbe83fd8757f197a9ce9d82f","SHA256Sum":"a842e715f5d20abb852281bd79ce0f06279564dcde37b4454e8db23153764e25","Size":"13MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"Installation":{"Command":"setup","CommandParams":"-t D8000 -v 0130 -i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff -i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff -l D8000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d8000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d8000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d8000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d8000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d8000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d8000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"ja","Value":"HPE D800012 Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"},{"Lang":"cn","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D8000 12Gb Enclosure","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"},{"Id":"ven_0x1590&dev_0x02db","TargetGUID":"","Type":"pcie"},{"Id":"D8000 12Gb IO","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-09T10:28:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Rhel 7.8のサポートを追加しました </p></li><li><p>Rhel 8.2のサポートを追加しました </p></li><li><p>SLES15 SP2のサポートを追加しました</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support of RHEL 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>RHEL 8.7のサポートを追加</p></li><li><p>RHEL 9.1のサポートを追加 </p></li><li><p>SLES15 SP4のサポートを追加</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support of RHEL 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"}],"SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4629c034c3394719aea902485fa33c79"}]},{"ProductId":"adefe97a484140f28ccdb1e9dfb3903c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 9.0"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 9.0"},{"Lang":"ja","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;2.2.3.0.</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;2.2.3.0.</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;2.2.3.0.</p>"}],"Files":[{"Bytes":"592750","DateModified":"2025-10-21T04:01:54","FileList":["/cp067479.xml","/Intel-icen_2.2.3.0-1OEM.900.0.24755229.zip","/Intel-icen_2.2.3.0-1OEM.900.0.24755229.zip/index.xml","/Intel-icen_2.2.3.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-icen_2.2.3.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-icen_2.2.3.0-1OEM.900.0.24755229.zip/vib20/icen/INT_bootbank_icen_2.2.3.0-1OEM.900.0.24755229.vib","/Intel-icen_2.2.3.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-icen_2.2.3.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-icen_2.2.3.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/icen--2938001856363402479.xml","/Intel-icen_2.2.3.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-icen_2.2.3.0-1OEM.900.0.24755229.xml"],"MD5Sum":"f4068f5b64be1c3f082af5691ee6f878","Name":"cp067479.zip","Release":"2025-10-21T04:01:44","Revision":"","SHA1Sum":"69bc19ea857b1e8d4b1e7ab120763738214d3c50","SHA256Sum":"71bcaad5aa390cd2cc985ecc4d58d0252cc70d61ad5032a162553eaca58c9365","Size":"578KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"icen","Version":"2.2.3.0-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icen Driver for VMware vSphere 9.0"},{"Lang":"cn","Value":"Intel icen Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"Intel icen Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-06T03:14:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.7.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、DDPを新しいFWバージョンとNVM 4.7に合わせるように修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.7.</p>","Lang":"cn"}],"Version":"2025.05.00"},{"ReleaseNotes":[{"Enhancements":"<p>This product VMware ESXi 9 supported.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product VMware ESXi 9 supported.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product VMware ESXi 9 supported.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"Intel-icen:2.2.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:2.2.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"30cb9605ee2e4602b7fa1dd2cf29166b"}]},{"ProductId":"a77901ff235c43f18df58616eefb654e","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE NV60100M 100Gb 2p Strg Offload Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"22_45_1020-R8M41-63001_Ax_header.pldm.signed.flash","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d1590037d","Version":"22.45.1020"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE"},{"Lang":"ja","Value":"Mellanox HPE署名済みPLDMファームウェアパッケージfor HPE向けNVIDIA Ethernet 100Gb 2ポートNVMe-oFオフロードアダプター"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE</td><td>22.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE</td><td>22.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE</td><td>22.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7728938","DateModified":"2025-06-30T06:11:22","FileList":["22_45_1020-R8M41-63001_Ax_header.pldm.signed.flash","22_45_1020-R8M41-63001_Ax_header.pldm.xml","payload.json"],"MD5Sum":"f40e268156b69aebda0a4da1be91248a","Name":"22_45_1020-R8M41-63001_Ax_header.pldm.fwpkg","Release":"2025-06-30T06:08:44","Revision":"","SHA1Sum":"1a32f3726fcd0000115b17bbc62931684c1cda75","SHA256Sum":"428990927bca7fd1fdd09963709a552fdc38debc0f45b7208cf64dc72f937c67","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d1590037d"],"TypeOfChange":"1","Version":"22.45.1020"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package(FWPKG) for HPE NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ (FWPKG) for HPE向けHPE NVIDIA Ethernet 100Gb 2ポートNVMe-oFオフロードアダプター"},{"Lang":"cn","Value":"Mellanox Firmware Package(FWPKG) for HPE NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101D","SubDev":"037D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d1590037d","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-30T05:23:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Upgraded to version&nbsp;26.43.1014</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン26.43.1014にアップグレードされました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Upgraded to version&nbsp;26.43.1014</p>","Fixes":"","Lang":"cn"}],"Version":"26.43.1014"},{"ReleaseNotes":[{"Enhancements":"<p>Upgraded to version&nbsp;22.45.1020</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Upgraded to version&nbsp;22.45.1020</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Upgraded to version&nbsp;22.45.1020</p>","Fixes":"","Lang":"cn"}],"Version":"22.45.1020"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"7319fd82a07c4804b3f42bdb8e099c29"},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Eth 10/25Gb 2p Sec Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_45_1020-S2A69-63001_Ax_header.pldm.signed.flash","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101f159003fe","Version":"26.45.1020"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE"},{"Lang":"ja","Value":"Mellanox HPE署名済みPLDMファームウェアパッケージfor HPE向けNVIDIA Ethernet 10/25Gb 2ポートSFP28 NVMe-oF暗号アダプター"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE</td><td>26.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE</td><td>26.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE</td><td>26.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7172243","DateModified":"2025-07-24T04:54:16","FileList":["26_45_1020-S2A69-63001_Ax_header.pldm.signed.flash","26_45_1020-S2A69-63001_Ax_header.pldm.xml","payload.json"],"MD5Sum":"dfe472c139cf306152a43e16c6462fd0","Name":"26_45_1020-S2A69-63001_Ax_header.pldm.fwpkg","Release":"2025-07-24T04:52:14","Revision":"","SHA1Sum":"193a4343f5779fda246fd1d743eb567b8987a10e","SHA256Sum":"979b65d9f162dafbd4025fedc8f3625cc10a9bf73abe8225f1a17690d6a8cf1a","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f159003fe"],"TypeOfChange":"1","Version":"26.45.1020"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package(FWPKG) for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ (FWPKG) for HPE向けNVIDIA Ethernet 10/25Gb 2ポートSFP28 NVMe-oF暗号アダプター"},{"Lang":"cn","Value":"Mellanox Firmware Package(FWPKG) for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101F","SubDev":"03FE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f159003fe","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-30T05:15:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Upgraded to version&nbsp;26.43.1014</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン26.43.1014にアップグレードされました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Upgraded to version&nbsp;26.43.1014</p>","Fixes":"","Lang":"cn"}],"Version":"26.43.1014"},{"ReleaseNotes":[{"Enhancements":"<p>Upgraded to version&nbsp;26.45.1020</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン26.45.1020にアップグレードされました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Upgraded to version&nbsp;26.45.1020</p>","Fixes":"","Lang":"cn"}],"Version":"26.45.1020"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_PA_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"e2fbadb5ead3419e9adfd4a63f824341"}]},{"ProductId":"0f3487315f10473a903e3c353d754526","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor and chipset."},{"Lang":"ja","Value":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"625072","DateModified":"2025-11-17T06:27:12","FileList":["cp069696.xml","cpqsetup.exe","installer.dll","pnp/","pnp/NULL_HECI.cat","pnp/NULL_HECISystem.inf","pnp/RocketLake.cat","pnp/RocketLakeSystem.inf","pnp/TigerLakePCH-H.cat","pnp/TigerLakePCH-HSystem.inf"],"MD5Sum":"878234dfae6bb824180bc64212cea9af","Name":"cp069696.exe","Release":"2025-11-17T06:23:58","Revision":"B","SHA1Sum":"094a78dd7721ba6aa3a4f78dea138aaddb07a73d","SHA256Sum":"734da7bf563045929b968b4bd2e5feff0d03f704fa1edc1c10bea898f32b54c2","Size":"610KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19886.8592"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for Intel Xeon E-23xx Processor for Microsoft Windows"},{"Lang":"ja","Value":"Microsoft Windows用インテルXeon E-23xxプロセッサーの識別子"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-17T06:17:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19886.8592"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19886.8592"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"eb805e4703474f4d9f67ea754a1dc6f6"}]},{"ProductId":"da435657efe64ff1a664870254b46a1c","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8002-MCX653105A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30068","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe4 x16 MCX653105A-HDATアダプター: HPE部品番号P23664-B21およびP23664-H21 "},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p style=\"margin-left:40px\"><strong>HDR / 200GbEケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR対NDRスイッチ相互運用ケーブル：</strong></p><ul><li>HDR    P45733-B21    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10mスプリッターアクティブ光ケーブル</li><li>HDR    P45733-B22    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30mスプリッターアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6276057","DateModified":"2025-10-08T10:43:16","FileList":["20_43_8002-MCX653105A-HDA_HPE_Ax.pldm.signed","20_43_8002-MCX653105A-HDA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"d83703d56096fceb3ef06c07438a80fe","Name":"20_43_8002-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","Release":"2025-10-08T10:41:35","Revision":"","SHA1Sum":"ea7e99e34ce5c194ffec7a147b6fe73057033db2","SHA256Sum":"37c398aefe7e42dfd339f10834e6c6026f9091904f2319b5c158c04e5fffe90b","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"TypeOfChange":"1","Version":"20.43.8002"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ（FWPKG）for HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe4 x16 MCX653105A-HDATアダプター: HPE部品番号P23664-B21およびP23664-H21 "},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-08T10:14:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"20.43.8002"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653105A-HDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"96fb4f9e200647c5a4c98b1961c00272"}]},{"ProductId":"bafc8d47aead420a9621e8d49861aa9b","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v4.00 (01/09/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v4.00 (01/09/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33606112","DateModified":"2026-01-13T03:00:01","FileList":["A43_4.00_01_09_2026.signed.flash","A43_4.00_01_09_2026.xml","payload.json"],"MD5Sum":"1032693c9432e17dc0f5884e5452564c","Name":"A43_4.00_01_09_2026.fwpkg","Release":"2026-01-13T02:56:51","Revision":"","SHA1Sum":"9f8927d2ab58ef3629f2f34cef6a2d12ab67ecf1","SHA256Sum":"530a63c9d0701cbc7129db33ec968aa0e16f86243ccea7f8bcc11073d750bd8a","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"},{"Lang":"ja","Value":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus（A43）サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:38:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。</p><p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.92_11-27-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"fe035242a1e64422b7c3e5b6741024e6"}]},{"ProductId":"d626b04e2b74450287a682c2c77ab027","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_4704-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.4704"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8002-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.8002"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8002-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Windows x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Windows x86_64プラットフォームでHPE Apollo A10 InfiniBand EDR（100Gb）2ポートアダプター（HPE部品番号843400-B21）、HPE Apollo InfiniBand EDR 100Gb 2ポート841zメザニンアダプター（HPE部品番号872723-B21）、HPE InfiniBand EDR 100Gb 1ポート841QSFP28アダプター（HPE部品番号872725-B21）のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.4704</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.8002</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.8002</td><td>HPE0000000008</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.4704</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.8002</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.8002</td><td>HPE0000000008</td></tr></tbody></table>"}],"Files":[{"Bytes":"27644480","DateModified":"2025-12-02T09:21:14","FileList":["cp069163.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_4704-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","fw-ConnectX5-rel-16_35_8002-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","fw-ConnectX5-rel-16_35_8002-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"aaf2536c3816bac1de1783a62e058efc","Name":"cp069163.exe","Release":"2025-12-02T09:18:20","Revision":"","SHA1Sum":"1ee67d5a1acd318c39e8fddbd82d13a7f7ef02c6","SHA256Sum":"2febbe8475943ae45aec3a6ed5789b4ce11d9ed7f9179919a5c9a12f68905c33","Size":"26MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"TypeOfChange":"1","Version":"1.0.0.17"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p><p>&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p><p>&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Windows x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ（Windows x64）for HPE Mellanox IB専用ConnectX4およびConnectX5デバイス - Windows x86_64プラットフォーム"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00EF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000ef","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0257","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900257","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0255","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900255","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-12T16:19:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2ポートアダプター)<br /> </li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>872723-B21(HPE Apollo InfiniBand EDR 100Gb 2ポート841zメザニンアダプター)</li><li>872725-B21(HPE InfiniBand EDR 100Gb 1ポート841QSFP28アダプター)</li></ul><p> </p><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302では、新たな問題は修正されていません。</strong></p><p> </p><p><strong>以下の問題点がバージョン16.35.4506で修正されました。</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.0.16"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.8002:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.4704にアップデートされました。</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2ポートアダプター)<br /> </li></ul><p><strong>次のデバイス用のファームウェアが16.35.8002にアップデートされました。</strong></p><ul><li>872723-B21(HPE Apollo InfiniBand EDR 100Gb 2ポート841zメザニンアダプター)</li><li>872725-B21(HPE InfiniBand EDR 100Gb 1ポート841QSFP28アダプター)</li></ul><p> </p><p><strong>バージョン12.28.4704には、以下の新機能と変更が含まれます。</strong></p><ul><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。</li></ul><p> </p><p><strong>バージョン16.35.8002には、以下の新機能と変更が含まれます。</strong></p><ul><li>ファームウェア例外パス処理のパフォーマンスが向上し、構成されたSR-IOVインスタンスの数の増加をより適切にサポートできるようになりました。</li><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。</li></ul>","Fixes":"<p><strong>バージョン12.28.4704には修正は含まれていません。</strong></p><p> </p><p><strong>以下の問題点がバージョン16.35.8002で修正されました。</strong></p><ul><li>FWがCQ回復モードに入った後、ファームウェアはPFの正しいCQをスキャンできませんでした。その結果、PFのCQが回復されませんでした。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.8002:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.0.17"}],"SWKeys":[{"Name":"Mellanox_IB_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"541d779421014e428b8fc35d5d11c1de"}]},{"ProductId":"580943ac4a1c45d88b3e24b6ae5ef825","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL issued.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL issued.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"7271236","DateModified":"2025-07-31T10:45:21","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-1.1/CP067321.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-1.1/K503HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067321.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067321.scexe"],"MD5Sum":"191d24b77c1405d4c8cd9d7fd5a37080","Name":"firmware-hdd-8e1e8083c5_0HPG3-1.1_amd64.deb","Release":"2025-07-31T15:38:04","Revision":"","SHA1Sum":"a9c5782d6c58bad755db4bf5d89318127d487bf2","SHA256Sum":"a7ef66e0c82b5d8e66c73a7e64edf3fd35e7e432d6b42a60ccf5c200e9f14eb6","Size":"6MB","TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP043280.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MK003840GWXFL","TargetGUID":"4d2340a5-304b-3330-3834-30475758464c","Type":"sata"},{"Id":"MK001920GWXFK","TargetGUID":"4d2340a5-304b-3130-3932-30475758464b","Type":"sata"},{"Id":"MK000960GWXFH","TargetGUID":"4d2340a5-304b-3030-3936-304757584648","Type":"sata"},{"Id":"MK000480GWXFF","TargetGUID":"4d2340a5-304b-3030-3438-304757584646","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:21:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improve the FW about data mismatch after SPL issued.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Improve the FW about data mismatch after SPL issued.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improve the FW about data mismatch after SPL issued.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e4f7516e93954bd293ec9a888ae168c9"}]},{"ProductId":"3f2f70c223354bc6b59b77123faa8545","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWCPK、EH000600JWCPL、EH000300JWCPN、EH000300JXLVR、EH000600JXLVT、EH000900JXLVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"4028976","DateModified":"2025-11-18T13:35:20","FileList":["cp068656.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SKESTNDB.rel"],"MD5Sum":"be02fb2538c7393a24ab2841aab83da1","Name":"cp068656.exe","Release":"2025-11-18T13:29:37","Revision":"D","SHA1Sum":"b8b3bd831761906cd1ebb330c47d4948f56331d2","SHA256Sum":"0e778a085ea22546d937519806556fa9b9ecefae2eaa48d8c924e428aada2021","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000300JWCPK、EH000600JWCPL、EH000900JWCPN、EH000300JXLVR、EH000600JXLVT、およびEH000900JXLVUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EH000300JWCPK","TargetGUID":"452340a5-3048-3030-3330-304a5743504b","Type":"sas"},{"Id":"EH000600JWCPL","TargetGUID":"452340a5-3048-3030-3630-304a5743504c","Type":"sas"},{"Id":"EH000900JWCPN","TargetGUID":"452340a5-3048-3030-3930-304a5743504e","Type":"sas"},{"Id":"EH000900JXLVU","TargetGUID":"452340a5-3048-3030-3930-304a584c5655","Type":"sas"},{"Id":"EH000300JXLVR","TargetGUID":"452340a5-3048-3030-3330-304a584c5652","Type":"sas"},{"Id":"EH000600JXLVT","TargetGUID":"452340a5-3048-3030-3630-304a584c5654","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:46:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"06611b50fde44566a65773be616f675b"}]},{"ProductId":"6b0653271f3e4e3a8e730542d61ffed8","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The lsi-mr3 controller driver component for VMware vSphere 8.0, for use with HPE Smart Update Manager."},{"Lang":"ja","Value":"HPE Smart Update Managerで使用するVMware vSphere 8.0用lsi-mr3コントローラードライバーコンポーネント"},{"Lang":"cn","Value":"The lsi-mr3 controller driver component for VMware vSphere 8.0, for use with HPE Smart Update Manager."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"241119","DateModified":"2025-07-24T07:42:55","FileList":["/BCM_bootbank_lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240.vib","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip","/cp067936.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/index.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240.vib","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip/vmware.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip/vibs/lsi-mr3-2686125346731254711.xml","/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240_24694757.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.732.04.00-1OEM.800.1.0.20613240.xml"],"MD5Sum":"5cb4fd7a3944d5e8712139e81a970658","Name":"cp067936.zip","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"77890863b2fe5c356c56a6249bfcfcde87d75eaf","SHA256Sum":"af5e1dc766371915a54cf55dad0103e2ff3b89e6a0661ffbb17351cce25fad5b","Size":"235KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd","20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"TypeOfChange":"1","Version":"2025.09.01","VibList":[{"Name":"lsi-mr3","Version":"7.732.04.00-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hpe/swpackages and ./hpesum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p><p><strong>リモートオンライン：</strong></p><ul><li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li><li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hpe/swpackagesディレクトリにコピーします。</li><li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li><li> CD /hpe/swpackagesおよび./hpesum</li><li> 次へボタンを選択します。</li><li> シングルターゲットの追加をクリックします。</li><li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li><li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li> Smart Update Managerの指示に従ってアップデートを行います。</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ul><li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li><li> VUMおよびesxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</li></ul>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hpe/swpackages and ./hpesum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 8.0"},{"Lang":"ja","Value":"HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plusコントローラーおよびMR416i-p、MR416i-o、MR216i-o、MR408i-o、MR216i-p、MR408i-p Gen11コントローラードライバー(64ビット) for vSphere 8.0"},{"Lang":"cn","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T04:02:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11 and Gen10 Plus Storage Controllers - Purple&nbsp;Screen of Death (PSOD) May Be Observed When Updating Controller Firmware Via&nbsp;Service Pack for ProLiant (SPP) in Remote Deployment Mode With a VMware ESXi OS</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11およびGen10 Plusストレージコントローラー - VMware ESXi OSを使用してリモート展開モードでService Pack for ProLiant (SPP) によりコントローラーのファームウェアをアップデートすると、パープルスクリーン (PSOD) が発生する場合があります</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11 and Gen10 Plus Storage Controllers - Purple&nbsp;Screen of Death (PSOD) May Be Observed When Updating Controller Firmware Via&nbsp;Service Pack for ProLiant (SPP) in Remote Deployment Mode With a VMware ESXi OS</li></ul>","Lang":"cn"}],"Version":"2025.09.01"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11 and Gen10 Plus Storage Controllers - Purple&nbsp;Screen of Death (PSOD) May Be Observed When Updating Controller Firmware Via&nbsp;Service Pack for ProLiant (SPP) in Remote Deployment Mode With a VMware ESXi OS</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11およびGen10 Plusストレージコントローラー - VMware ESXi OSを使用してリモート展開モードでService Pack for ProLiant (SPP) によりコントローラーのファームウェアをアップデートすると、パープルスクリーン (PSOD) が発生する場合があります</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix a00145710en_us: HPE MR Gen11 and Gen10 Plus Storage Controllers - Purple&nbsp;Screen of Death (PSOD) May Be Observed When Updating Controller Firmware Via&nbsp;Service Pack for ProLiant (SPP) in Remote Deployment Mode With a VMware ESXi OS</li></ul>","Lang":"cn"}],"Version":"2025.09.01"}],"SWKeys":[{"Name":"Broadcom-lsi-mr3:7.732.04.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"lsi-mr3:7.732.04.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e9ec7ff017e1463a8bde5873dfbb2737"}]},{"ProductId":"871bd1fc79994166a0695e4fb3b5fd65","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A46_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34031331","DateModified":"2026-01-12T20:50:11","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.00_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.00_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.00_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.00_2026_01_09-1.1/A46_4.00_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.00_2026_01_09-1.1/CP070348.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.00_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.00_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.00_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.00_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070348.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070348.scexe"],"MD5Sum":"f97826a8f68ef42b2178fbfa36af8035","Name":"firmware-system-a46-4.00_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T02:41:38","Revision":"","SHA1Sum":"402da7ed3459424f68224be3ea92fb94676fb994","SHA256Sum":"ceb7225af098df8afac99ecc9ee935e770ed23f4bf09a8591a8eabe5041135b6","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL225n Gen10 Plus (A46) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL225n Gen10 Plus (A46) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL225n Gen10 Plus (A46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:41:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.92_11-27-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cf0c305631da4bd6a0da1e6b5ce2a9fc"}]},{"ProductId":"7ebf7b3b32234babb113c6746f09f68e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U38_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11899948","DateModified":"2026-01-12T01:02:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.62_2026_01_09-1.1/CP070254.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.62_2026_01_09-1.1/U38_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070254.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070254.scexe"],"MD5Sum":"fb6ef083f65b25358464207d53e1f03f","Name":"firmware-system-u38-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-12T06:50:40","Revision":"","SHA1Sum":"59a5b6018d3012c76de63f7c73cb60b5abe6a926","SHA256Sum":"a60cff40e171d72bd82429f36b2a72d55e15b1083dfdc9970300cd99b7569397","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:47:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cec0af2164fe4a3a81dc265ebc4cd6e7"}]},{"ProductId":"1d81dab4bd3149b19db9381601c1abce","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.35.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under Linux x86_64 platform Only."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームのみで動作するHPE ProLiant Gen10サーバーシリーズのBroadcom NX1 Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under Linux x86_64 platform Only."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v20.35.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>HPE Ethernet 1Gb 2-port 330i Adapter (22BD)</td><td>2.10</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>HPE Ethernet 1Gb 4-port 331i Adapter (22BE)<br />HPE Ethernet 1Gb 4-port 331FLR Adapter<br />HPE Ethernet 1Gb 4-port 331T Adapter</td><td>1.64</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>HPE Ethernet 1Gb 2-port 332i Adapter (22E8)<br />HPE Ethernet 1Gb 2-port 332T Adapter</td><td>1.43</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr></tbody></table><p>For previous firmware versions prior to v20.19.51, please refer to the link :&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c\">https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c</a></p>"},{"Lang":"ja","Value":"<p>This software package contains combo image v20.35.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>HPE Ethernet 1Gb 2-port 330i Adapter (22BD)</td><td>2.10</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>HPE Ethernet 1Gb 4-port 331i Adapter (22BE)<br />HPE Ethernet 1Gb 4-port 331FLR Adapter<br />HPE Ethernet 1Gb 4-port 331T Adapter</td><td>1.64</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>HPE Ethernet 1Gb 2-port 332i Adapter (22E8)<br />HPE Ethernet 1Gb 2-port 332T Adapter</td><td>1.43</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr></tbody></table><p>For previous firmware versions prior to v20.19.51, please refer to the link :&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c\">https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c</a></p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v20.35.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>HPE Ethernet 1Gb 2-port 330i Adapter (22BD)</td><td>2.10</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>HPE Ethernet 1Gb 4-port 331i Adapter (22BE)<br />HPE Ethernet 1Gb 4-port 331FLR Adapter<br />HPE Ethernet 1Gb 4-port 331T Adapter</td><td>1.64</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr><tr><td>HPE Ethernet 1Gb 2-port 332i Adapter (22E8)<br />HPE Ethernet 1Gb 2-port 332T Adapter</td><td>1.43</td><td>21.6.4</td><td>1.5.65</td><td>21.6.92</td></tr></tbody></table><p>For previous firmware versions prior to v20.19.51, please refer to the link :&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c\">https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c</a></p>"}],"Files":[{"Bytes":"6801096","DateModified":"2025-11-25T00:57:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/CP069009.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/CP069009.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/nic_fw/330i-2x1G-14E4-1665-103C-22BD.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/nic_fw/331FLR-4x1G-14E4-1657-103C-169D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/nic_fw/331T-4x1G-14E4-1657-103C-3383.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/nic_fw/331i-4x1G-14E4-1657-103C-22BE.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/nic_fw/332T-2x1G-14E4-165F-103C-1786.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/nic_fw/332i-2x1G-14E4-165F-103C-22E8.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.42.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069009.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069009.scexe"],"MD5Sum":"05767ecaedbf740464ca106ea49683c2","Name":"firmware-nic-bcm-2.42.0-1.1.x86_64.rpm","Release":"2025-11-25T06:49:57","Revision":"","SHA1Sum":"c11ed17a90b45e4fc0d6a1b507d7c815244ac53a","SHA256Sum":"80b0a3707c637253c759a3d4153e9469a5f36d0ab6691d97fdee0220c628145b","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"2.42.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm</em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p><ul><li>ファームウェアrpmパッケージをインストールします。<br /><em>> rpm -ivh <rpm_filename>.rpm</em></li><li>ファイルを抽出する場所を確認します。<br /><em>> rpm -qlp <rpm_filename>.rpm</em></li><li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li></ul><p> </p><p><strong><em>追加情報：</em></strong></p><ul><li>詳細情報はCPxxxxxx.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCPxxxxxx.logに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm</em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen10 server series Only."},{"Lang":"ja","Value":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティfor Linux x86_64（HPE ProLiant Gen10サーバーシリーズ専用）。"},{"Lang":"cn","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen10 server series Only."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T06:06:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"2.41.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during &nbsp;Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during &nbsp;Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during &nbsp;Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed</li></ul>","Lang":"cn"}],"Version":"2.42.0"}],"SWKeys":[{"Name":"BCM","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"8759ff6a29bc41ccab329ef71f7b0c75"}]},{"ProductId":"e6fc00ad6a3e4c539778e7419a9fafa6","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8002-MCX653435A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900347","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe4 x16 MCX653435A-HDAIアダプター: HPE部品番号P31323-B21およびP31323-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p style=\"margin-left:40px\"><strong>HDR / 200GbEケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR対NDRスイッチ相互運用ケーブル：</strong></p><ul><li>HDR    P45733-B21    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10mスプリッターアクティブ光ケーブル</li><li>HDR    P45733-B22    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30mスプリッターアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6276684","DateModified":"2025-10-08T12:23:18","FileList":["20_43_8002-MCX653435A-HDA_HPE_Ax.pldm.signed","20_43_8002-MCX653435A-HDA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"b11dae53a8271bd88dcbe699689b5ff2","Name":"20_43_8002-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","Release":"2025-10-08T12:20:57","Revision":"","SHA1Sum":"d284efaa83d5c9e8ce387e844d2b406ff1619579","SHA256Sum":"80f21eae744d2378dff14b767579bb53b2a6fd982015095d10021ae34cba69ed","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900347"],"TypeOfChange":"1","Version":"20.43.8002"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ（FWPKG）for HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe4 x16 OCP3 MCX653435A-HDAIアダプター: HPE部品番号P31323-B21およびP31323-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-08T11:46:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"20.43.8002"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653435A-HDAI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"4abbb390a3c34470b4525b8b7d2ab579"}]},{"ProductId":"29772c9b119b47c898dedcff775e1472","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4759820","DateModified":"2025-08-02T21:12:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-1.1/CP067366.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-1.1/HVLAeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067366.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067366.scexe"],"MD5Sum":"856786cc52432e8e1b6569ceb34ef88f","Name":"firmware-hdd-7f2a26e6d0_0HPG1-1.1_amd64.deb","Release":"2025-08-03T02:06:08","Revision":"","SHA1Sum":"ec6fa178da6ebe68f8792448e14e9b0ffcea9217","SHA256Sum":"3aeca4a7aba27145ec8617cc582137091301d9635d25cc5908e10fa376694e89","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP041521.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000GWKGR Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000GWKGR Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000GWKGR","TargetGUID":"4d2340a5-3042-3630-3030-3047574b4752","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T20:24:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cab36fd5cbdb4bfaa0cea9daf4c1041b"}]},{"ProductId":"cdfe3840d6074900a4d11b774d3e5307","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_4704-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4704"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_4704-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4704"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8002-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8002"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8002-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Windows x86_64 platform."},{"Lang":"ja","Value":"このパッケージは、Windows x86_64プラットフォーム上でHPE VPI (EthernetおよびInfinibandモードで動作) ConnectX4およびConnectX5デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"}],"Files":[{"Bytes":"29759024","DateModified":"2025-12-02T05:44:50","FileList":["cp069158.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_4704-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","fw-ConnectX4-rel-12_28_4704-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","fw-ConnectX5-rel-16_35_8002-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","fw-ConnectX5-rel-16_35_8002-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"e8cba375981fbd997aa91573a48a0f1a","Name":"cp069158.exe","Release":"2025-12-02T05:42:37","Revision":"","SHA1Sum":"c28e6224b767a404627494369135d167ce884568","SHA256Sum":"3c694fa16ecb42cdb178a747e729784b7d38b19e02bcfe31c8975a303d5fc304","Size":"28MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.0.18"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p><p>&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p><p>&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Windows x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ (Windows x64) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX4およびConnectX5デバイス - Windows x86_64プラットフォーム"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T14:29:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1ポート840QSFP28アダプター)</li><li>825111-B21(HPE InfiniBand EDR/Ethernet 100Gb 2ポート840QSFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>879482-B21(HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター)</li><li>872726-B21（HPE InfiniBand EDR/Ethernet 100Gb 2ポート 841QSFP28アダプター）</li></ul><p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン12.28.2302には新機能の追加も変更もありません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302に追加された新しい修正はありません。</strong></p><p> </p><p><strong>以下の問題点がバージョン16.35.4506で修正されました。</strong></p><p> </p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.0.17"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.4704にアップデートされました。</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1ポート840QSFP28アダプター)</li><li>825111-B21(HPE InfiniBand EDR/Ethernet 100Gb 2ポート840QSFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.8002にアップデートされました。</strong></p><ul><li>879482-B21(HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター)</li><li>872726-B21（HPE InfiniBand EDR/Ethernet 100Gb 2ポート 841QSFP28アダプター）</li></ul><p> </p><p><strong>バージョン12.28.4704には、以下の新機能と変更が含まれます。</strong></p><ul><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。</li></ul><p> </p><p><strong>バージョン16.35.8002には、以下の新機能と変更が含まれます。</strong></p><ul><li>ファームウェア例外パス処理のパフォーマンスが向上し、構成されたSR-IOVインスタンスの数の増加をより適切にサポートできるようになりました。</li><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。</li></ul>","Fixes":"<p><strong>バージョン12.28.4704には修正は含まれていません。</strong></p><p> </p><p><strong>以下の問題点がバージョン16.35.8002で修正されました。</strong></p><ul><li>FWがCQ回復モードに入った後、ファームウェアはPFの正しいCQをスキャンできませんでした。その結果、PFのCQが回復されませんでした。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.0.18"}],"SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"42c949f4534a41bdaee1312418602ca2"}]},{"ProductId":"4549aae264234c4c8ee7e64a5c9b1222","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H10","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H10_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on HPE Edgeline e920, e920d and e920t CTO Blade Server running a supported Operating System in an HPE Edgeline EL8000t Converged Edge System."},{"Lang":"ja","Value":"このコンポーネントは、HPE Edgeline EL8000tコンバージドエッジシステムでサポートされているオペレーティングシステムを実行しているHPE Edgeline e920t、e920dおよびe920t CTOブレードサーバーに直接インストールできるアップデートされたシステムファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on HPE Edgeline e920, e920d and e920t CTO Blade Server running a supported Operating System in an HPE Edgeline EL8000t Converged Edge System."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33981265","DateModified":"2026-01-12T00:47:54","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.54_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.54_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.54_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.54_2026_01_09-1.1/CP070259.xml","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.54_2026_01_09-1.1/H10_2.54_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.54_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.54_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.54_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.54_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070259.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070259.scexe"],"MD5Sum":"2e45416b2c588286bd024d15b3835643","Name":"firmware-system-h10-2.54_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-12T06:40:33","Revision":"","SHA1Sum":"0332b50352b0058d5d710549f860deb0d41eaf7b","SHA256Sum":"b6392767f7adc209a9ea33fb3106480530f5c1f49a8b59fc9919e6b7a716e299","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023a"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Edgeline e920, e920d and e920t CTOブレードサーバー(H10)"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:57:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where megacell batteries might not manifest correctly.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where megacell batteries might not manifest correctly.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where megacell batteries might not manifest correctly.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_10-03-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"H10","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"FTP","Model":"FTP-Only System"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"554c1007625b4cde857b6419d955e0ac"}]},{"ProductId":"b0391b3a14de43ee99f90e7fe9de4040","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U56_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33600908","DateModified":"2026-01-12T03:45:20","FileList":["payload.json","U56_2.54_01_09_2026.signed.flash","U56_2.54_01_09_2026.xml"],"MD5Sum":"43a819d6499f4e658175471c759c037d","Name":"U56_2.54_01_09_2026.fwpkg","Release":"2026-01-12T03:41:28","Revision":"","SHA1Sum":"c2c9a193b8ec6b5d349486b02fecb24012dba0b6","SHA256Sum":"a0344acf2a600d906a1bfdfdef6a2f7b95dd8cff445aa9c067043c919a2694a9","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000239"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE DL110 Gen10 Plus Telco (U56) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE DL110 Gen10 Plus Telco（U56）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE DL110 Gen10 Plus Telco (U56) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:40:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Whitley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.802（2.50_07_24_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U56","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"c3c8a085e4014a89976cff7fd6076365"}]},{"ProductId":"074cd65cf284444dbd64a63e5f809ff6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB014000GWUDA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4666648","DateModified":"2025-11-15T17:57:16","FileList":["cp068747.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEBsssATFG3.rel"],"MD5Sum":"4ee96c32ec6fa7ebf572b95dfb4975ca","Name":"cp068747.exe","Release":"2025-11-15T17:52:15","Revision":"D","SHA1Sum":"cce44c2241988e373511e6996b4850ffebc641bd","SHA256Sum":"88c03aed91155b0f886a5e1ff73a73101b213591ae5d5ed0c0f1968489fbf4e4","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWUDA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB014000GWUDAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000GWUDA","TargetGUID":"4d2340a5-3042-3431-3030-304757554441","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:25:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2dbde1482fdc4b03bbfab4b3b37a422b"}]},{"ProductId":"ccd2fccdbff94b0ab75d085d46522784","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.5"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"14232673","DateModified":"2025-11-18T23:40:50","FileList":["./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/CP068479.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/elxflashStandalone-linux-14.4.731.5-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/firmware/B1447315.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/firmware/P1447315.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.11.01-1.7/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068479.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068479.scexe"],"MD5Sum":"831a979b3b483a6ea722334274027bf9","Name":"firmware-fc-emulex-2025.11.01-1.7.x86_64.rpm","Release":"2025-11-19T05:28:43","Revision":"","SHA1Sum":"be5d605af1ed7f9d529cc3f852b9b645e261a691","SHA256Sum":"9a43bde3683722e4b5784fc15b78216c7c0d6926c8005ca51e043aacbd2ed948","Size":"13MB","TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2025.11.01"}],"Installation":{"Command":"installer","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />&nbsp;<br />&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems) .<br />&nbsp;<br />&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />&nbsp;<br />&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command : rpm -e &lt;rpm_package_name&gt;.</p>"},{"Lang":"ja","Value":"<p>ファームウェアインストールは、2段階のプロセスです。  ファームウェアインストールツールrpmをインストールし、ファームウェアをアップデートするため、インストールしたツールを実行します。<br /> <br /> 1. ファームウェアインストレーションツール：rpm -Uvh <rpm_package_name>.rpmをインストールします。これにより、ファームウェアインストレーションツールが/usr/lib/x86_64-linux-gnuに抽出されます (64ビットシステム) 。<br /> <br /> 2. 使用するシステムの適切な場所へcdし、./setupを実行してファームウェアをアップデートします<br /> <br /> ファームウェアインストレーションの完了後は、rpm -eコマンド (rpm -e <rpm_package_name>) を使用して、システムからファームウェアインストレーションツールを削除してもかまいません。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)"},{"Lang":"ja","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"20000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-21T09:53:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>Fixed the Following:</p><ol><li>Switch Login Incomplete After Firmware Upgrade</li><li>Boot Incomplete on RHEL 10</li></ol>","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>以下を修正しました。</p><ol><li>ファームウェアのアップグレード後にスイッチのログインが完了できない</li><li>RHEL 10でブートが完了できない</li></ol>","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>Fixed the Following:</p><ol><li>Switch Login Incomplete After Firmware Upgrade</li><li>Boot Incomplete on RHEL 10</li></ol>","Lang":"cn"}],"Version":"2025.09.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.11.01"}],"SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"7693db8e77574e03a7405784eee64a2f"}]},{"ProductId":"8783f0c30a1545f88feb3a27a7839584","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"4653256","DateModified":"2025-08-02T21:14:51","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-1.1/CP067371.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-1.1/HVLPeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067371.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067371.scexe"],"MD5Sum":"e47e2f30e2eed74fa0c51090db107631","Name":"firmware-hdd-8b26d1ef02_0HPD2-1.1_amd64.deb","Release":"2025-08-03T02:06:18","Revision":"","SHA1Sum":"54095fe0a1baec295da264653c73c0429b39472d","SHA256Sum":"81b88f68753bef5a1a5e0f115d7f24ff04b5bc59f3434737611d52b5f470d887","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041479.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWRTD Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWRTD Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000JWRTD","TargetGUID":"4d2340a5-3042-3830-3030-304a57525444","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T20:52:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul>","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"26642fd9af7a4ff09e86d6b1c1bbfcf0"}]},{"ProductId":"e485f42530b84989a3373bff82088143","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Operating System - Enhancements"},{"Lang":"ja","Value":"オペレーティング システム - 拡張"},{"Lang":"cn","Value":"操作系统 - 增强功能"}],"Description":[{"Lang":"en","Value":"This components installs the AMD PSHED service"},{"Lang":"ja","Value":"このコンポーネントはAMD PSHEDサービスをインストールします"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"630384","DateModified":"2025-11-16T14:10:22","FileList":["cp069670.xml","cpqsetup.exe","installer.dll","non-pnp/","non-pnp/amdpshed.cat","non-pnp/amdpshed.inf","non-pnp/amdpshed.sys"],"MD5Sum":"8fa5dd1cc51293436abcda4bd05b62a8","Name":"cp069670.exe","Release":"2025-11-16T14:08:00","Revision":"B","SHA1Sum":"1850c83f4a988cc95ff1168f24af16043035efa8","SHA256Sum":"00289058e393cff1285e7033f8ce278d50b2159af05be72e4f542de5455aa620","Size":"615KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"TypeOfChange":"1","Version":"1.0.0.51"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"AMD PSHED Plug-in service for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"AMD PSHEDプラグインサービスfor Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"100"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-16T14:04:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Driver update</li><li>Updated supported platforms</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ドライバーアップデート</li><li>サポートされるプラットフォームをアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Driver update</li><li>Updated supported platforms</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.51"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Update setup utility dependencies.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Update setup utility dependencies.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Update setup utility dependencies.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.51"}],"SWKeys":[{"Name":"amdpshed.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"","Model":"HPE Cray XD295v"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"9001e38f8173493b9fb7ad5c3a48876e"}]},{"ProductId":"ec5ba4f75ae340e39f8e129f646a9647","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8002"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1908"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Linux Operating Systems."},{"Lang":"ja","Value":"このパッケージには、Linuxオペレーティングシステム上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Linux Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"}],"Files":[{"Bytes":"8683592","DateModified":"2025-10-10T01:54:16","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/CP068981.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1908-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1908-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/nic_fw/fw-ConnectX5-rel-16_35_8002-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.14-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068981.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068981.scexe"],"MD5Sum":"049422dc2301d6022f37c71a0dfaa610","Name":"firmware-nic-open-mellanox-eth-mft-1.0.14-1.1.x86_64.rpm","Release":"2025-10-10T06:50:40","Revision":"","SHA1Sum":"56a2a53cb32103de99494470ec7e53ed85e429b5","SHA256Sum":"2b77731ccc5bd4220ed7985846fcb252b77d099b531b717b355072467e2facd4","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p><ul><li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li><li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li><li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li><li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li><li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li><li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox Open Ethernet cards"},{"Lang":"ja","Value":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（Linux x86_64）"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox Open Ethernet cards"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-29T06:26:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4506:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>P21930-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4121A-XCATアダプター)</li><li>P11341-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4621A-ACAB OCP3アダプター)</li></ul><p> </p><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>P21927-B21（HPE Ethernet 100Gb 2ポートQSFP28 MCX516A-CCHTアダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4506で修正されました：</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4506:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.13"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.14"}],"SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"4516ab79d8314703aba17c80a84f47ec"}]},{"ProductId":"79ba405b8c19425aa9a14902b672b652","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3865.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen9 and Gen10 server series HPE ProLiant Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 8.0 and 9.0"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen9 and Gen10 server series HPE ProLiant Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 8.0 and 9.0"},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 8.0および9.0で動作するHPE ProLiant Gen9およびGen10サーバーシリーズHPE ProLiant Intel Gigabit Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"24376873","DateModified":"2025-09-16T09:34:47","FileList":["/CP068726_BUILD_2.data","/CP068726.vmexe64","/CP068726.vmfile","/CP068726_VMw.zip","/CP068726.xml","/payload.json","/CP068726_VMw.zip/index.xml","/CP068726_VMw.zip/vendor-index.xml","/CP068726_VMw.zip/metadata.zip","/CP068726_VMw.zip/vib20/CP068726/HPE_bootbank_CP068726_3.28.0.2-8.0.0.20613240.vib","/CP068726_VMw.zip/metadata.zip/vendor-index.xml","/CP068726_VMw.zip/metadata.zip/vmware.xml","/CP068726_VMw.zip/metadata.zip/vibs/CP068726-1514695831961737474.xml","/CP068726_VMw.zip/metadata.zip/bulletins/Smart-Component-CP068726_3.28.0.2-8.0.0.20613240.xml"],"MD5Sum":"077c043a3eb16b65d247107555b2052b","Name":"CP068726.zip","Release":"2025-09-16T09:34:06","Revision":"","SHA1Sum":"d5e81f2ad0bc1f50c311248f2dc8b3644cc32817","SHA256Sum":"b179775febe44e32397361aa466b4dab8b09708cde43b245cff3f52dfa9cab5c","Size":"23MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"3.28.0","VibList":[{"Name":"CP068726","Version":"3.28.0.2-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":3600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 4-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li>次のネットワークアダプターについては、アップデートを反映させるためにファームウェアのインストール後にAC電源を再投入する必要があります。<br />HPE Ethernet 1Gb 2ポート368iアダプター<br />HPE Ethernet 1Gb 4ポート369iアダプター<br />HPE Ethernet 1Gb 2ポート368FLR-MMTアダプター<br />HPE Ethernet 10Gb 2ポート568FLR-MMSFP+アダプター<br />HPE Ethernet 10Gb 2ポート568FLR-MMTアダプター</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 4-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel Online Firmware Upgrade Utility VMware for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"cn","Value":"HPE Intel Online Firmware Upgrade Utility VMware for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"ja","Value":"HPE Intelオンラインファームウェアアップグレードユーティリティfor VMware（HPE ProLiant Gen9およびGen10サーバーシリーズ専用）。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T03:04:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、タイムアウトにより 562SFP+/x710 アダプターでFWアップグレードが失敗する問題を修正しました。</li><li>この製品は、4ポートイーサーネットアダプターでリンクがダウンしているときに、ポート2とポート3がリンクダウンを報告しないことがある問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"cn"}],"Version":"3.27.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"3.28.0"}],"SWKeys":[{"Name":"INTEL","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"99db24b0e9774c86837e6bfdad981319"}]},{"ProductId":"ce9f91a90e53444d84d0e7a4367d6fd4","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 8.0"},{"Lang":"ja","Value":"このコンポーネントパッケージには、VMware vSphere 8.0で動作するHPE Intel icen Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.15.4.0.</p>"},{"Lang":"ja","Value":"<p>この製品には、ドライバーバージョン1.15.4.0が含まれています。</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.15.4.0.</p>"}],"Files":[{"Bytes":"919738","DateModified":"2025-09-16T06:54:12","FileList":["/cp067478.xml","/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.zip","/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.zip/index.xml","/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.zip/vib20/icen/INT_bootbank_icen_2.2.2.0-1OEM.800.1.0.20613240.vib","/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/icen-587811272340985144.xml","/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Intel-icen_2.2.2.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"0da032f63bfe4d3709fecc920d2b2f4b","Name":"cp067478.zip","Release":"2025-09-16T06:54:03","Revision":"","SHA1Sum":"319f71d8f30f9971b8c626e75e17f41c7c82bbaa","SHA256Sum":"a2498e7d45848d6c34f2035281a57ba6abbe315e173986c496e24c0fd075f792","Size":"898KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"icen","Version":"2.2.2.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icen Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"Intel icenドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"Intel icen Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-06T03:13:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.7.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、DDPを新しいFWバージョンとNVM 4.7に合わせるように修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.7.</p>","Lang":"cn"}],"Version":"2025.05.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"Intel-icen:2.2.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:2.2.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"92f7231dfbbd46198b761e0044113773"}]},{"ProductId":"c20869f6e72044ccb4d2b142b029a1ef","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWJAN、MB002000GWFWA および MB004000GWFWB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>A minor reliability enhancement involving an extra head cleaning operation</li><li>Preventive corner-case and situational adjustments for a potential Read hang, rare weak read and some &ldquo;housekeeping&rdquo; items (display, command outputs, delay on power-up and log maintenance)</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>A minor reliability enhancement involving an extra head cleaning operation</li><li>Preventive corner-case and situational adjustments for a potential Read hang, rare weak read and some &ldquo;housekeeping&rdquo; items (display, command outputs, delay on power-up and log maintenance)</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5505616","DateModified":"2025-09-17T11:54:40","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/CP068855.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/TATCATSATAG1.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068855.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068855.scexe"],"MD5Sum":"b32ce25d736f79d4dcc4a9557debf470","Name":"firmware-hdd-d39e7a7e75-HPG1-15.1.x86_64.rpm","Release":"2025-09-17T16:42:05","Revision":"O","SHA1Sum":"b1bb096ab0886b6fe4af19db55bd1a4a71df5e9c","SHA256Sum":"1c5da7435c7e896f1d27219528d9f9ed4f79ec18a72b135baa7026a315ddb3eb","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040351.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000GWFWB","TargetGUID":"4d2340a5-3042-3430-3030-304757465742","Type":"sata"},{"Id":"MB002000GWFWA","TargetGUID":"4d2340a5-3042-3230-3030-304757465741","Type":"sata"},{"Id":"MB001000GWJAN","TargetGUID":"4d2340a5-3042-3130-3030-3047574a414e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:39:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d7123f9b68d74ac2a66fa30f9bd71127"}]},{"ProductId":"98e23edaa7ef4fdeb2cf62fce8396e6a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB002000JYDNE and MB004000JYDPB"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB002000JYDNE and MB004000JYDPB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB002000JYDNE and MB004000JYDPB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB002000JYDNE and MB004000JYDPB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"4771476","DateModified":"2025-08-02T20:48:22","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-1.1/CP067358.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-1.1/SCIMARBPNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067358.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067358.scexe"],"MD5Sum":"0a6533d0f4989252de3330be4e80efb7","Name":"firmware-hdd-d4be2aecbb_0HPD6-1.1_amd64.deb","Release":"2025-08-03T01:42:16","Revision":"","SHA1Sum":"c01255b5e15849c22a4847fadb0aee8ea472e3c2","SHA256Sum":"5b2ff15ba0f370e31250def09fe40d3fdff0fb7f69c1d40667ef062ac0a0a9cc","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB002000JYDNE and MB004000JYDPB Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB002000JYDNE and MB004000JYDPB Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JYDPB","TargetGUID":"4d2340a5-3042-3430-3030-304a59445042","Type":"sas"},{"Id":"MB002000JYDNE","TargetGUID":"4d2340a5-3042-3230-3030-304a59444e45","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:53:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9083b3c59cc140e781ee9327885fc355"}]},{"ProductId":"cd81ec29d7e54f55ab77712a180c1fe2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60およびKCM6FVUL3T20"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20&nbsp; Drives<br />&nbsp;<strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20&nbsp; Drives<br />&nbsp;<strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4691336","DateModified":"2025-11-17T10:16:21","FileList":["cp068652.xml","cpqsetup.exe","KACM6ALFGPK6.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"ce826744e1c9b9cdcd4ef575f8e46e75","Name":"cp068652.exe","Release":"2025-11-17T10:11:04","Revision":"B","SHA1Sum":"0b25b6cf45cc22f587cb896d91381525e9c5ed7b","SHA256Sum":"3c26def9c3523a9eb1d796282173658dc5d1347022a56603e0690ef56e272277","Size":"4MB","TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives"},{"Lang":"ja","Value":"オンラインNVMeSSDフラッシュコンポーネントfor Windows（x64）- KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60、およびKCM6FVUL3T20ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"KCM6FRUL1T92","TargetGUID":"002340a5-434b-364d-4652-554c31543932","Type":"nvme"},{"Id":"KCM6FRUL3T84","TargetGUID":"002340a5-434b-364d-4652-554c33543834","Type":"nvme"},{"Id":"KCM6FVUL3T20","TargetGUID":"002340a5-434b-364d-4656-554c33543230","Type":"nvme"},{"Id":"KCM6FVUL1T60","TargetGUID":"002340a5-434b-364d-4656-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:42:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>リセットの問題と定期的なメンテナンスファームウェアアップデートを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>リセットの問題と定期的なメンテナンスファームウェアアップデートを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK6"}],"SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"830635266472425cad538063c1577b28"}]},{"ProductId":"dcf87aae93de4d649fef4547bffe751a","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8002-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8002"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8002-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8002"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8002-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージは、Linux x86_64プラットフォーム上でHPE VPI（EthernetおよびInfinibandモードで動作）ConnectX6デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"},{"Lang":"cn","Value":"This package contains utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Linux x86_64 platform."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"}],"Files":[{"Bytes":"9072584","DateModified":"2025-10-10T00:37:15","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/CP069134.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/nic_fw/fw-ConnectX6-rel-20_43_8002-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/nic_fw/fw-ConnectX6-rel-20_43_8002-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/nic_fw/fw-ConnectX6-rel-20_43_8002-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069134.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069134.scexe"],"MD5Sum":"2a7a83be2aa0cc32f5b2fde4fc0273a1","Name":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.19-1.1.x86_64.rpm","Release":"2025-10-10T05:31:53","Revision":"","SHA1Sum":"6ba08c5e9ebada1211832692695b42c274acfe17","SHA256Sum":"447688d676fe282dadc844f7f8a4823eb25065de3c5462da03b07002c6debd4a","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.19"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ（Linux x86_64）for HPE NVIDIA VPI（EthernetおよびInfinibandモード）ConnectX4デバイス - Linux x86_64プラットフォーム"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-09T06:33:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが20.43.2566にアップデートされました。</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-HDATアダプター- P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-ECATアダプター- P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe3 x16 MCX653106A-ECATアダプター- P06251-B21</li></ul><p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"1.0.18"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"1.0.19"}],"SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"0e96e30e7e1040e9b9381713936c3994"}]},{"ProductId":"7c61cb3283de42b790100730aaa7c9b2","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"849964","DateModified":"2025-11-18T06:51:24","FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"MD5Sum":"2bbf1d731e4289632092b6cd8f38eda7","Name":"elx-lpfc-kmp-default-14.4.731.6_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","Release":"2025-11-18T06:48:32","Revision":"","SHA1Sum":"19b18b80ef6ea5ae3d4cbe9f6b97c5ca574d1247","SHA256Sum":"a1fee52733d1c9101ed5ef681329e6b8e734adb9c83cf3c477a84abb7b7109b4","Size":"830KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.731.6"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.520.3_k5.14.21_150500.37-1.sles15sp5.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.520.3_k5.14.21_150500.37-1.sles15sp5.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.520.3_k5.14.21_150500.37-1.sles15sp5.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"},{"Lang":"ja","Value":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-23T05:01:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>SUSE Linux Enterprise Server 16</p><p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added support for:</p><p>SUSE Linux Enterprise Server 16</p><p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>SUSE Linux Enterprise Server 16</p><p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.731.6"}],"SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"77373931870e4fb8bf35aa740edf2866"}]},{"ProductId":"1d674b6248104e069b7fb661a7f5441b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM1000JFJTH"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MM1000JFJTH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4107008","DateModified":"2025-08-03T02:20:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-1.1/CP067350.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-1.1/SAVGNSD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067350.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067350.scexe"],"MD5Sum":"d6bdc93fba1213b2405b8a3667821968","Name":"firmware-hdd-fa46c607d6_0HPD5-1.1_amd64.deb","Release":"2025-08-03T07:14:05","Revision":"","SHA1Sum":"c84a3fd3eda5688e29ffbe55513aa7ee1270ae6b","SHA256Sum":"f492f4c6396a576de3dc7bf8fed8b97ad231b56e3947f70cdd810df92bc54959","Size":"3MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a464a5448"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MM1000JFJTH Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MM1000JFJTH Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM1000JFJTH","TargetGUID":"002340a5-4d00-314d-3030-304a464a5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:41:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MM1000JFJTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b92bcd26a45f4e4aa5d2b67e8f35310e"}]},{"ProductId":"17ae190412f049ff80b7f941eb9e3732","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A46_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33596640","DateModified":"2026-01-13T02:47:00","FileList":["A46_4.00_01_09_2026.signed.flash","A46_4.00_01_09_2026.xml","payload.json"],"MD5Sum":"45a52bc77b18f87a3da7663a9f2bcb49","Name":"A46_4.00_01_09_2026.fwpkg","Release":"2026-01-13T02:43:50","Revision":"","SHA1Sum":"7819e692a36a56d43d0f2eb318409030bf494682","SHA256Sum":"eef8b34aa46134e1c17883611f14c556cb62117e7956ef747f9d256f2b0ddaa0","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant XL225n Gen10 Plus (A46) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant XL225n Gen10 Plus (A46) サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant XL225n Gen10 Plus (A46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:37:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.92_11-27-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"3345935dd7614e8880940116edbd1057"}]},{"ProductId":"cf85e5cea71d4be281d746fc27728160","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This firmware revision improves data integrity and reliability by optimizing adjacent track refresh parameters and management of emergency power loss table structure.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in emergency power loss events.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide some minor performance improvements.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This firmware revision improves data integrity and reliability by optimizing adjacent track refresh parameters and management of emergency power loss table structure.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in emergency power loss events.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide some minor performance improvements.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4420492","DateModified":"2025-08-02T22:11:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-1.1/CP067389.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-1.1/TAMG08acHPG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067389.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067389.scexe"],"MD5Sum":"5cc4b8d4fa2e40f7b765bf97800c974b","Name":"firmware-hdd-e4f147cdd2_0HPG4-1.1_amd64.deb","Release":"2025-08-03T03:02:21","Revision":"","SHA1Sum":"aea171de0e2d853b1dde9b07596e7fc2da27d2a3","SHA256Sum":"d255c9c42c098227e32614971083f87022f056601f09ade2c6918f8f594468ce","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000GWXKK Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000GWXKK Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB016000GWXKK","TargetGUID":"4d2340a5-3042-3631-3030-304757584b4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:30:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware revision improves data integrity and reliability by optimizing adjacent track refresh parameters and management of emergency power loss table structure.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in emergency power loss events.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide some minor performance improvements.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware revision improves data integrity and reliability by optimizing adjacent track refresh parameters and management of emergency power loss table structure.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in emergency power loss events.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide some minor performance improvements.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware revision improves data integrity and reliability by optimizing adjacent track refresh parameters and management of emergency power loss table structure.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in emergency power loss events.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide some minor performance improvements.</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"937a1baf30064cb1bae72125e82af735"}]},{"ProductId":"8bd617958fd64494b0066602dc57ff65","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp067924.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2648960","DateModified":"2025-11-14T05:46:17","FileList":["cp067924.compsig","cp067924.zip","cp069634.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"a77d7d2a924ff285e56d3e56978fcc75","Name":"cp069634.exe","Release":"2025-11-14T05:44:50","Revision":"B","SHA1Sum":"8b02105d8ca4543b7140bf6000e32cdb5492f45a","SHA256Sum":"e7052da269aa0179e0b14028a97a106aa23cbe9004b998061a8064b0de38f8ef","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20/ML30 Gen10"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T05:31:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 05.01.05.103は、システムROM 3.70 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Server Platform Servicesファームウェアのこのリビジョンは、CVE-2025-20067として文書化されているセキュリティ上の脆弱性を緩和します。この問題は、HPEサーバーに固有のものではありません。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"05.01.05.103"},{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 05.01.05.103は、システムROM 3.70 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Server Platform Servicesファームウェアのこのリビジョンは、CVE-2025-20067として文書化されているセキュリティ上の脆弱性を緩和します。この問題は、HPEサーバーに固有のものではありません。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"05.01.05.103"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fa5190582aad429fb4ad708a9c44f101"}]},{"ProductId":"261c2f9a8f584fd69c7ae5c1643322e4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF,V K001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK,MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK,MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"16649800","DateModified":"2025-03-06T11:10:39","FileList":["/CP065971_BUILD_13.data","/CP065971.vmexe64","/CP065971.vmfile","/CP065971_VMw.zip","/CP065971.xml","/payload.json","/CP065971_VMw.zip/index.xml","/CP065971_VMw.zip/vendor-index.xml","/CP065971_VMw.zip/metadata.zip","/CP065971_VMw.zip/vib20/CP065971/HPE_bootbank_CP065971_HPG5.13-8.0.0.20613240.vib","/CP065971_VMw.zip/metadata.zip/vendor-index.xml","/CP065971_VMw.zip/metadata.zip/vmware.xml","/CP065971_VMw.zip/metadata.zip/vibs/CP065971--7373643190641160641.xml","/CP065971_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065971_HPG5.13-8.0.0.20613240.xml"],"MD5Sum":"6b95fffbb63e29b1240e054fdf497251","Name":"CP065971.zip","Release":"2025-03-06T11:09:51","Revision":"J","SHA1Sum":"3479f3079ebe99841d2ed0a6837124cf16fa7e14","SHA256Sum":"fed8e9fef663c7702dd17aa56e5c2c9230b005d9c19b9c2e3eed0a0b3bd122fb","Size":"15MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP065971","Version":"HPG5.13-8.0.0.20613240"}]}],"Installation":{"Command":"CP042736.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MK001920GWJPQ","TargetGUID":"4d2340a5-304b-3130-3932-3047574a5051","Type":"sata"},{"Id":"MK000240GWKVK","TargetGUID":"4d2340a5-304b-3030-3234-3047574b564b","Type":"sata"},{"Id":"MK000480GWJPN","TargetGUID":"4d2340a5-304b-3030-3438-3047574a504e","Type":"sata"},{"Id":"MK000960GWJPP","TargetGUID":"4d2340a5-304b-3030-3936-3047574a5050","Type":"sata"},{"Id":"VK003840GWJPK","TargetGUID":"562340a5-304b-3330-3834-3047574a504b","Type":"sata"},{"Id":"VK001920GWJPH","TargetGUID":"562340a5-304b-3130-3932-3047574a5048","Type":"sata"},{"Id":"VK000960GWJPF","TargetGUID":"562340a5-304b-3030-3936-3047574a5046","Type":"sata"},{"Id":"VK000480GWJPE","TargetGUID":"562340a5-304b-3030-3438-3047574a5045","Type":"sata"},{"Id":"VK000240GWJPD","TargetGUID":"562340a5-304b-3030-3234-3047574a5044","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:44:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5bda8aab3a0f4794810c9b2b92732953"}]},{"ProductId":"628a576c95694de3aab72daab877bb47","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20314881","DateModified":"2025-03-06T09:17:56","FileList":["/CP066010_BUILD_5.data","/CP066010.vmexe64","/CP066010.vmfile","/CP066010_VMw.zip","/CP066010.xml","/payload.json","/CP066010_VMw.zip/index.xml","/CP066010_VMw.zip/vendor-index.xml","/CP066010_VMw.zip/metadata.zip","/CP066010_VMw.zip/vib20/CP066010/HPE_bootbank_CP066010_HPD4.5-8.0.0.20613240.vib","/CP066010_VMw.zip/metadata.zip/vendor-index.xml","/CP066010_VMw.zip/metadata.zip/vmware.xml","/CP066010_VMw.zip/metadata.zip/vibs/CP066010-2648125330980124201.xml","/CP066010_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066010_HPD4.5-8.0.0.20613240.xml"],"MD5Sum":"95c8fbe95e5176d7ba9ea233ca7cc3ed","Name":"CP066010.zip","Release":"2025-03-06T09:17:12","Revision":"C","SHA1Sum":"0d428abe43450494d42563a02c9542cfea92ef9b","SHA256Sum":"6092c1c4056fa54750c4e6c7970781f8a1e65eacecc73985aa6cbf9b8dd8104d","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP066010","Version":"HPD4.5-8.0.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB010000JWZHA","TargetGUID":"4d2340a5-3042-3031-3030-304a575a4841","Type":"sas"},{"Id":"MB012000JWZHB","TargetGUID":"4d2340a5-3042-3231-3030-304a575a4842","Type":"sas"},{"Id":"MB016000JWZHE","TargetGUID":"4d2340a5-3042-3631-3030-304a575a4845","Type":"sas"},{"Id":"MB014000JWZHC","TargetGUID":"4d2340a5-3042-3431-3030-304a575a4843","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:08:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6025ac4d83194e2c9c1ebd2935c8df60"}]},{"ProductId":"1607ed48320345de80b2a91bfe782685","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1036936","DateModified":"2025-11-16T04:29:15","FileList":["cp069551.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs.cat","ixs.inf","ixs.sys","ixsmsg.dll","nicdrvr.dll"],"MD5Sum":"c22d5eacdc7cf77dc84df543845249ea","Name":"cp069551.exe","Release":"2025-11-16T04:15:04","Revision":"D","SHA1Sum":"0f6a563758edbd7548fc32917e79375c18fcddaf","SHA256Sum":"2bafd7d88d662165a8e744dc76355866aa66805ca28e367e8c97e419f0887fdb","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"TypeOfChange":"1","Version":"4.1.254.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixs Driver for Windows Server 2022"},{"Lang":"ja","Value":"Windows Server 2022用HPE Intel ixsドライバー"},{"Lang":"cn","Value":"HPE Intel ixs Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、INF ファイルをアップデートして、DmaRemappingcompatible 機能を値 2 で有効にするように修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"cn"}],"Version":"4.1.254.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、INF ファイルをアップデートして、DmaRemappingcompatible 機能を値 2 で有効にするように修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"cn"}],"Version":"4.1.254.0"}],"SWKeys":[{"Name":"ixs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\ixs.inf_amd64_166a1f78fe537c55"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b70a0115b54549caa0ab62a22d2d87db"}]},{"ProductId":"23ed237c56c047b39f75b9977e930a45","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000JZYVN、MB014000JZYVP、MB016000JZYVQ、MB018000JYCLK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - &nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - &nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19902900","DateModified":"2025-03-07T11:22:00","FileList":["/CP065973_BUILD_3.data","/CP065973.vmexe64","/CP065973.vmfile","/CP065973_VMw.zip","/CP065973.xml","/payload.json","/CP065973_VMw.zip/index.xml","/CP065973_VMw.zip/vendor-index.xml","/CP065973_VMw.zip/metadata.zip","/CP065973_VMw.zip/vib20/CP065973/HPE_bootbank_CP065973_HPD4.3-1OEM.800.1.0.20613240.vib","/CP065973_VMw.zip/metadata.zip/vendor-index.xml","/CP065973_VMw.zip/metadata.zip/vmware.xml","/CP065973_VMw.zip/metadata.zip/vibs/CP065973--5253502155574354171.xml","/CP065973_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065973_HPD4.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"5d11351acc23b4ddd891a86c645777a8","Name":"CP065973.zip","Release":"2025-03-07T11:21:04","Revision":"C","SHA1Sum":"ce68325d6bbd9b3cf3f4f05e42ccb53505d207a8","SHA256Sum":"1f0f83cf664bdde258edd8d0bea17306b03ef7ab5f2068902f63c4bfb8ebbf43","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065973","Version":"HPD4.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQおよびMB018000JYCLKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB012000JZYVN","TargetGUID":"4d2340a5-3042-3231-3030-304a5a59564e","Type":"sas"},{"Id":"MB014000JZYVP","TargetGUID":"4d2340a5-3042-3431-3030-304a5a595650","Type":"sas"},{"Id":"MB016000JZYVQ","TargetGUID":"4d2340a5-3042-3631-3030-304a5a595651","Type":"sas"},{"Id":"MB018000JYCLK","TargetGUID":"4d2340a5-3042-3831-3030-304a59434c4b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:47:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"442b737a911c4ce88402c62648838ae7"}]},{"ProductId":"5f5babdc8edb43cda68a851809a46823","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JXUCC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JXUCC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5337568","DateModified":"2025-11-15T16:43:14","FileList":["cp068750.xml","cpqsetup.exe","mnv_cli.exe","payload.json","PCHFA2BP.rel","setup.dll"],"MD5Sum":"597c8604e9bc85907c4e911b2e3e21d0","Name":"cp068750.exe","Release":"2025-11-15T16:37:46","Revision":"D","SHA1Sum":"cb2a334b3392f6bd6b292515073997ed671f96bc","SHA256Sum":"b0bf3e8493ec71a5447a25d723fe4e04a666eef512bd788a029018b32e7c1746","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JXUCC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JXUCCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000JXUCC","TargetGUID":"4d2340a5-3042-3431-3030-304a58554343","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:26:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"20c192b14fdb4fb3a6a567aa634cf151"}]},{"ProductId":"1d44852ea69b4bbc91ed4be4d1a7792a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"4879236","DateModified":"2025-08-03T01:19:46","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-1.1/CP067333.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-1.1/KACD6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067333.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067333.scexe"],"MD5Sum":"fe5a3d15ce9f75824a3e44c600a9982d","Name":"firmware-hdd-6fc985bd3b_0GPK8-1.1_amd64.deb","Release":"2025-08-03T06:11:08","Revision":"","SHA1Sum":"1f4c6f10a1c7b4e9ec61ee9e61a40b24195ae847","SHA256Sum":"db969f2a82465294b2bc062f987471a52f45138b2dbbdf876f437bfa53e5adc0","Size":"4MB","TargetGUIDs":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCD6XLUL7T68","TargetGUID":"002340a5-434b-3644-584c-554c37543638","Type":"nvme"},{"Id":"KCD6XVUL6T40","TargetGUID":"002340a5-434b-3644-5856-554c36543430","Type":"nvme"},{"Id":"KCD6XVUL1T60","TargetGUID":"002340a5-434b-3644-5856-554c31543630","Type":"nvme"},{"Id":"KCD6XVUL800G","TargetGUID":"002340a5-434b-3644-5856-554c38303047","Type":"nvme"},{"Id":"KCD6XVUL3T20","TargetGUID":"002340a5-434b-3644-5856-554c33543230","Type":"nvme"},{"Id":"KCD6XLUL960G","TargetGUID":"002340a5-434b-3644-584c-554c39363047","Type":"nvme"},{"Id":"KCD6XLUL1T92","TargetGUID":"002340a5-434b-3644-584c-554c31543932","Type":"nvme"},{"Id":"KCD6XLUL3T84","TargetGUID":"002340a5-434b-3644-584c-554c33543834","Type":"nvme"},{"Id":"KCD6XVUL12T8","TargetGUID":"002340a5-434b-3644-5856-554c31325438","Type":"nvme"},{"Id":"KCD6XLUL15T3","TargetGUID":"002340a5-434b-3644-584c-554c31355433","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:58:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK8"}],"SWKeys":[{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1e209eb0643448c7807a68cd1e86d10f"}]},{"ProductId":"0b3bbfed90454334ba3331c2f9efa2ea","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：<br />     </strong>オンラインHDD/SSDフラッシュコンポーネントfor ESXi - VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ</p><p><strong>リリースバージョンおよび/または日付:<br />     </strong>HPD5</p><p><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPD4</p><p><strong>前のファームウェアバージョン：</strong><br />     HPD4<br /><br /><strong>ファームウェアの関連性：  </strong></p><p>     なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />      なし</p>"}],"Files":[{"Bytes":"18459509","DateModified":"2025-03-06T11:19:42","FileList":["/CP065944_BUILD_2.data","/CP065944.vmexe64","/CP065944.vmfile","/CP065944_VMw.zip","/CP065944.xml","/payload.json","/CP065944_VMw.zip/index.xml","/CP065944_VMw.zip/vendor-index.xml","/CP065944_VMw.zip/metadata.zip","/CP065944_VMw.zip/vib20/CP065944/HPE_bootbank_CP065944_HPD5.2-1OEM.800.1.0.20613240.vib","/CP065944_VMw.zip/metadata.zip/vendor-index.xml","/CP065944_VMw.zip/metadata.zip/vmware.xml","/CP065944_VMw.zip/metadata.zip/vibs/CP065944--8710370949825720746.xml","/CP065944_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065944_HPD5.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"b6b34bc0fd854fe2766329a81018aaa9","Name":"CP065944.zip","Release":"2025-03-06T11:18:57","Revision":"C","SHA1Sum":"b1d48ce6b30dcaaff3187f21f9fb9d5b62bb100c","SHA256Sum":"e9b4ab42c30a066b3a028b5e64ead38480356eb0466aa8e70341734cabeb70d3","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP065944","Version":"HPD5.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043253.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO015360JWZJN","TargetGUID":"562340a5-304f-3531-3336-304a575a4a4e","Type":"sas"},{"Id":"VO007680JWZJL","TargetGUID":"562340a5-304f-3730-3638-304a575a4a4c","Type":"sas"},{"Id":"VO003840JWZJK","TargetGUID":"562340a5-304f-3330-3834-304a575a4a4b","Type":"sas"},{"Id":"VO001920JWZJH","TargetGUID":"562340a5-304f-3130-3932-304a575a4a48","Type":"sas"},{"Id":"VO000960JWZJF","TargetGUID":"562340a5-304f-3030-3936-304a575a4a46","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:28:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8c3ce5786422481ca1e335852104a165"}]},{"ProductId":"6d5b098230e341e9881e9381bf19ba96","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-iavf-4.9.1-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-iavf) to (iavf). Now we revert this change from (iavf) to (<strong>hp</strong>-iavf).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-iavf and kmod-iavf are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-iavf-4.9.1-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-iavf and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-iavf-4.9.1-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-iavf）から（iavf）に変更されました。この変更を（iavf）から（<strong>hp</strong>-iavf）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-iavfとkmod-iavfはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-iavf-4.9.1-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-iavfによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-iavf-4.9.1-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-iavf) to (iavf). Now we revert this change from (iavf) to (<strong>hp</strong>-iavf).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-iavf and kmod-iavf are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-iavf-4.9.1-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-iavf and then install the updated RPM.</p>"}],"Files":[{"Bytes":"180291","DateModified":"2025-09-15T16:09:12","FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-iavf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/61","./usr/lib/.build-id/61/57de86bfc1436f08e06752e3495de35e73a311","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"MD5Sum":"19866c1da08788f8596a8e444547fb44","Name":"kmod-hp-iavf-4.13.16-1.rhel9u5.x86_64.rpm","Release":"2025-09-15T16:03:08","Revision":"","SHA1Sum":"b74281dad5aa994c0098cebbe876c82cbac1b38a","SHA256Sum":"f4c76f993e782f9e184d7f9e8b97ecdd362df80b8da21cf8367aa415b829dc94","Size":"176KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"TypeOfChange":"1","Version":"4.13.16-1"},{"Bytes":"180467","DateModified":"2025-09-15T16:13:27","FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-iavf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/71","./usr/lib/.build-id/71/d2c39afe77009b2ba626a96f13cc2bf614d950","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"MD5Sum":"c56e44b5f3919a0f69cb745f1c6c9191","Name":"kmod-hp-iavf-4.13.16-1.rhel9u6.x86_64.rpm","Release":"2025-09-15T16:03:08","Revision":"","SHA1Sum":"913e8fc7cd6c8a90b0fa9c3c4bff5394d08ecb54","SHA256Sum":"2417a3257ab8ef708a585ccf1c0b93e6988da278b083bf8047370f194a634a9b","Size":"176KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"TypeOfChange":"1","Version":"4.13.16-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel iavf ドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"15FF","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15ff8086000c","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37cd","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"0dd5","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"12D3","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-12d380860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-22T08:11:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes default number of queues to resolve RSS issues.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、RSSの問題を解決するためにデフォルトのキューの数を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes default number of queues to resolve RSS issues.</p>","Lang":"cn"}],"Version":"4.13.14-1"},{"ReleaseNotes":[{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"4.13.16-1"}],"SWKeys":[{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"214bcf2b57c04da08ce6776aac488797"}]},{"ProductId":"03c87662bb3a4a57a852807a8f77de3f","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051643.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":" This component provides updated IE firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":" このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたIEファームウェアを提供します。 "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8569032","DateModified":"2025-11-26T02:56:20","FileList":["./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/CP069821.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/cp051643.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/cp051643.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069821.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069821.scexe"],"MD5Sum":"1cf3f81b11b9ba5eb12ae8dd0fba7b55","Name":"firmware-iegen10plus-1.0.0.22-9.1.x86_64.rpm","Release":"2025-11-26T08:50:07","Revision":"I","SHA1Sum":"514afdb399cd08ccfc22d428a171ec7f8c61da12","SHA256Sum":"68d0546178be4c47c10bb2c01daf7b4c1b7bf3e190129afc7ebc111a0e3775d0","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><br />To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><p>&nbsp;</p><ul></ul>"},{"Lang":"ja","Value":"<p><br />To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><p>&nbsp;</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - HPE Gen10 Plus Innovation Engineファームウェアfor HPE Gen10 Plusサーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-26T08:27:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(F) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>Ver 1.0.0.22(F)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver  1.0.0.22と同等です。ファームウェアをバージョン1.0.0.22にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョンFにアップグレードする必要はありません。</p><p>このLinuxコンポーネントは、Service Pack for ProLiant 2024.11.00.00 と互換性があります。</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(F) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(I) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision I if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(I) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision I if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(I) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision I if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"}],"SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:sd:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b751449de7e3448b90a977acbc3c01e9"}]},{"ProductId":"4b83f1a7716845c5a3d89ea69bd8a6a7","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"Lang":"ja","Value":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"Lang":"cn","Value":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Supplemental Update / Online ROM Flash Component for Ubuntu&ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;5.15<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Supplemental Update / Online ROM Flash Component for Ubuntu&ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;5.15<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Supplemental Update / Online ROM Flash Component for Ubuntu&ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;5.15<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3457140","DateModified":"2025-08-06T02:48:45","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-1.1/CP068088.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-1.1/firmware-Signed-5.15-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068088.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068088.scexe"],"MD5Sum":"6e2ad99cff8482c5f27d59fdf6664f6a","Name":"firmware-smartarray-1f19a4a64d_5.15-1.1_amd64.deb","Release":"2025-08-06T07:35:19","Revision":"","SHA1Sum":"284113aeb69c1b8905239306d8c941405ea1f9c3","SHA256Sum":"eec40273e9463c356cd82520665e0e6cba4b6daad5568fefccb5d6e7a1d15e7f","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"Installation":{"Command":"CP068088.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Procedure to update firmware from Ubuntu operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension.</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run launch_sum.sh script which is found in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Procedure to update firmware from Ubuntu operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension.</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run launch_sum.sh script which is found in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"cn","Value":"<p><strong>Procedure to update firmware from Ubuntu operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension.</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run launch_sum.sh script which is found in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Supplemental Update / Online ROM Flash Component for Ubuntu – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"ja","Value":"Supplemental Update / Online ROM Flash Component for Ubuntu – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"cn","Value":"Supplemental Update / Online ROM Flash Component for Ubuntu – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-09-05T07:31:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial Build</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Initial Build</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial Build</p>","Fixes":"","Lang":"cn"}],"Version":"5.15"}],"SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"56ff4c02b6444232816699a470183894"}]},{"ProductId":"f3f8a4081d78499e9a2dd9c8d9fb4059","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_4p90_PLDMoMCTP_80020EF2.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"4.90"}]},"MinimumActiveVersion":"4.20","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-CQDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80020EF2</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター</td><td>80020EF2</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.9と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80020EF2</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"}],"Files":[{"Bytes":"10526408","DateModified":"2025-12-18T07:10:12","FileList":["HPE_E810_CQDA2_4p90_PLDMoMCTP_80020EF2.HPb","HPE_E810_CQDA2_4p90_PLDMoMCTP_80020EF2.xml","payload.json"],"MD5Sum":"ebc0c7ea12c16ea384b4153709c28bf9","Name":"HPE_E810_CQDA2_4p90_PLDMoMCTP_80020EF2.fwpkg","Release":"2025-12-18T07:06:18","Revision":"B","SHA1Sum":"e4911e6cb014d1a1814785f40dc49d23272729bd","SHA256Sum":"19d2e00b08e84c300c51c5633b77388ab4f90d80dc709b8a8aae157f4c80d583","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860002"],"TypeOfChange":"1","Version":"4.90"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-18T06:15:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</li><li>This product enhanced media type detection function on PHY on 100G adapter.</li></ul>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</li><li>この製品は、100GアダプターのPHY上のメディアタイプ検出機能を強化しました。</li></ul>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</li><li>This product enhanced media type detection function on PHY on 100G adapter.</li></ul>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"},{"ReleaseNotes":[{"Enhancements":"<ul><li>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</li><li>This product enhanced media type detection function on PHY on 100G adapter.</li></ul>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</li><li>この製品は、100GアダプターのPHY上のメディアタイプ検出機能を強化しました。</li></ul>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</li><li>This product enhanced media type detection function on PHY on 100G adapter.</li></ul>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"}],"SWKeys":[{"Name":"INTEL_E810_CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"c1784f3b92234d5d8944742c77db4f74"}]},{"ProductId":"62fc8de385854321919207903df8d568","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5285553","DateModified":"2025-11-11T09:26:44","FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-qla2xxx","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"MD5Sum":"c5bf6cab67733e0717fd5013ad2b9d42","Name":"kmod-qlgc-qla2xxx-10.02.15.00_k1-1.rhel9u7.x86_64.rpm","Release":"2025-11-11T09:19:04","Revision":"","SHA1Sum":"9c46e0c15eff51448b1d8abeb778b8d59e8a45a4","SHA256Sum":"a9c36d5d8dcc8ff589efc4e68b2fe34cb0307a2375e293638cd5e8d9753b4667","Size":"5MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.15.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel9u7.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel9u7.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel9u7.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 9 Update 7 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 Update 7 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 9 Update 7 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T08:49:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.15.00-k1"}],"SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a31aceb185784562a36bd3cdbeea58cf"}]},{"ProductId":"6e4df08455db4ce3a3b07b6eecea6280","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and 6 (iLO 5, 6 and 7) Embedded Health and Alerting."},{"Lang":"ja","Value":"Agentless Management Service（AMSD）は、Integrated Lights Out 5、6および7（iLO 5、6および7）内蔵ヘルスおよびアラートのサポートを提供します。"},{"Lang":"cn","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and 6 (iLO 5, 6 and 7) Embedded Health and Alerting."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9970161","DateModified":"2026-01-09T02:57:57","FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/02","./usr/lib/.build-id/02/9435e3dd531715a6082d2d6338f32827062110","./usr/lib/.build-id/10","./usr/lib/.build-id/10/67e6817ef0f2e75ec240062d8e413407938faa","./usr/lib/.build-id/65","./usr/lib/.build-id/65/a11447c1df4aa0b301e35690e174a76d3f9a83","./usr/lib/.build-id/65/a11447c1df4aa0b301e35690e174a76d3f9a83.1","./usr/lib/.build-id/9b","./usr/lib/.build-id/9b/920d2137d6d15e7c24e02f4b332c48a56a9123","./usr/lib/.build-id/9b/920d2137d6d15e7c24e02f4b332c48a56a9123.1","./usr/lib/.build-id/a4","./usr/lib/.build-id/a4/68e33cedc4d4b0befa4a9170829b3e699d225e","./usr/lib/.build-id/a4/68e33cedc4d4b0befa4a9170829b3e699d225e.1","./usr/lib/.build-id/ac","./usr/lib/.build-id/ac/581625b8bcc946261c22769a09795d78455263","./usr/lib/.build-id/ac/5b61a729af8285540774276ee350e1ec670da8","./usr/lib/.build-id/ac/5b61a729af8285540774276ee350e1ec670da8.1","./usr/lib/.build-id/e0","./usr/lib/.build-id/e0/9116af89f7a55c9f35f41f3105f63308f65a6d","./usr/lib/.build-id/e0/9116af89f7a55c9f35f41f3105f63308f65a6d.1","./usr/lib/.build-id/e6","./usr/lib/.build-id/e6/0565cdfaf50936c81fdc23db930b481ff83e19","./usr/lib/.build-id/e6/0565cdfaf50936c81fdc23db930b481ff83e19.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"MD5Sum":"a9a9ade2b7891ade15ca9337d650dfc7","Name":"amsd-4.5.0-2110.2.rhel9.x86_64.rpm","Release":"2026-01-09T08:42:37","Revision":"","SHA1Sum":"7677ed9817b9540a0c588323fb0de48ba984d7b8","SHA256Sum":"6629322885ba8bc67e360fa534ee232d8717352ea27974776d6a7afc458ed09d","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.5.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 9 Server"},{"Lang":"ja","Value":"Agentless Management Service (iLO 5、iLO 6およびiLO 7) for Red Hat Enterprise Linux 9 Server"},{"Lang":"cn","Value":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 9 Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330615903307","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330715903307","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-08T08:48:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"4.4.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"4.5.0"}],"SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U74","Model":"HPE ProLiant Compute XD230 (U74)"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"831aaa631b044444bf229e814d8bd866"}]},{"ProductId":"a529a1b0d8b0405f80457239f0d32b29","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 10."},{"Lang":"ja","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 10."},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 10."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1355130","DateModified":"2025-12-12T06:35:16","FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/6.12.0-55.11.1.el10_0.x86_64","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra/bnxt_en","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra/bnxt_en/drivers","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"MD5Sum":"3701b22da55722c51e96395553542ad0","Name":"kmod-bnxt_en-1.10.3-235.1.164.14.rhel10u0.x86_64.rpm","Release":"2025-12-12T06:27:56","Revision":"","SHA1Sum":"f9fdbca23852cd2f5efd40fffff612e3c47cda00","SHA256Sum":"30823ee8e91cf3867b07cb55e111b7175b9efd8352f74cae0be55e84ae08246d","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 10"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 10"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-20T02:08:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"1.10.3-235.1.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"1.10.3-235.1.164.14"}],"SWKeys":[{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"8e35585af64849d9a9b92d4cb546c7b9"}]},{"ProductId":"ae8b95207bc948489c851dd62c16f373","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3998280","DateModified":"2025-11-15T16:28:16","FileList":["BCHPC17M.bin","cp068751.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"04908d67adbf337b7acdf7ed4d03f2d7","Name":"cp068751.exe","Release":"2025-11-15T16:23:09","Revision":"C","SHA1Sum":"a65fb6986f02b1e011b5913383dc14d4d0756cea","SHA256Sum":"53ba1ab716f10ca27ae636bb2241d1b2ca7b543eef93f44d54354b96add09501","Size":"3MB","TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA、およびMO003200JWDLBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EO001600JWDKR","TargetGUID":"452340a5-304f-3130-3630-304a57444b52","Type":"sas"},{"Id":"MO001600JWDLA","TargetGUID":"4d2340a5-304f-3130-3630-304a57444c41","Type":"sas"},{"Id":"MO003200JWDLB","TargetGUID":"4d2340a5-304f-3330-3230-304a57444c42","Type":"sas"},{"Id":"EO000400JWDKP","TargetGUID":"452340a5-304f-3030-3430-304a57444b50","Type":"sas"},{"Id":"MO000400JWDKU","TargetGUID":"4d2340a5-304f-3030-3430-304a57444b55","Type":"sas"},{"Id":"EO000800JWDKQ","TargetGUID":"452340a5-304f-3030-3830-304a57444b51","Type":"sas"},{"Id":"MO000800JWDKV","TargetGUID":"4d2340a5-304f-3030-3830-304a57444b56","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:48:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、推定発効日2024年8月9日のHPE Customer Bulletin（<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>）を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、推定発効日2024年8月9日のHPE Customer Bulletin（<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>）を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e5d44479dcd241aa80b77c5e9a3eaf67"}]},{"ProductId":"35cb34a457a347fd86df4f560cf6cf57","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Linux Operating Systems."},{"Lang":"ja","Value":"このパッケージには、Linuxオペレーティングシステム上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Linux Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"}],"Files":[{"Bytes":"3359704","DateModified":"2025-10-10T05:49:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/CP069150.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1908-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.9-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069150.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069150.scexe"],"MD5Sum":"ce126de3dee667efb80feede5d9251bb","Name":"firmware-nic-mellanox-eth-only-mft-1.0.9-1.1.x86_64.rpm","Release":"2025-10-10T10:46:54","Revision":"","SHA1Sum":"3d3e9eed3d11a435eab0a0d6be83c17ce0f7e3da","SHA256Sum":"82d6fdd9df93a1fd59366c06d0b47c57f5c128cb4577f0e64196de0f2a5e19bc","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.9"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p><ul><li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li><li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li><li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li><li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li><li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li><li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"Lang":"ja","Value":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（Linux x86_64）"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T09:19:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1904:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>P11338-B21(HPE Ethernet 10Gb 2ポート548SFP+アダプター)</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1904:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul>","Lang":"cn"}],"Version":"1.0.8"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"cn"}],"Version":"1.0.9"}],"SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"caf4e5f4ae5c4b96b576fa770c695f5c"}]},{"ProductId":"dcd60b858b6c4ac298dc49b61299aeb5","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.23"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このパッケージには、Microsoft Windows Server 2022とWindows Server 2025で動作するHPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3135624","DateModified":"2025-11-14T03:15:19","FileList":["cp069564.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.65.23.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"6a6f2297dd285d34161c19986b519870","Name":"cp069564.exe","Release":"2025-11-14T03:06:10","Revision":"C","SHA1Sum":"4ca6b16424201e083799e99ff472dab17685621b","SHA256Sum":"79d1ff0171005901d4547aaa06b78758829d9f6448cc8a49537b819c403621e5","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"5.3.7.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","SWKey":"qevbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.37.37.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR><P>From that drive and directory, execute the downloaded file. <BR><P>Click the \"Install\" button to proceed with the installation.</P><P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<BR><P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<BR><P>［インストール］ボタンをクリックして、インストールを開始します。</P><P>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</P>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-13T09:16:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"5.3.7.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Local 24H2 をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"cn"}],"Version":"5.3.7.0"}],"SWKeys":[{"Name":"QLBBFWUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"100ccd3730bb453988f65d8a8d2dacde"}]},{"ProductId":"2e589cc6a48f40eaa0870785c3351832","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U37_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11608560","DateModified":"2026-01-14T06:32:15","FileList":["cp070248.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U37_3.62_01_09_2026.signed.flash"],"MD5Sum":"ca7184c525c0aec063c5d4d67a1f9c29","Name":"cp070248.exe","Release":"2026-01-14T06:29:49","Revision":"","SHA1Sum":"558cd3a2d6ad7fbd0354d7c2ef0b571eeb3f0fdb","SHA256Sum":"f03ff30d8cc2b0db4acbcf133ab7c3ae6298cc2d89f539180f2fabd68a0352ee","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p>&nbsp;</p><p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul style=\"list-style-type:square\"><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p> </p><p style=\"margin-left:0in; margin-right:0in\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul style=\"list-style-type:square\"><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p>&nbsp;</p><p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul style=\"list-style-type:square\"><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230k Gen10 (U37) Server"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL230k Gen10 (U37)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230k Gen10 (U37) Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:37:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"29d0c504459a4a78b5391dce5102500c"}]},{"ProductId":"28da662386ba44b29fd0f050194b057e","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"cn","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Supplemental Update / Online ROM Flash Component for Ubuntu&nbsp;&ndash; HPE Apollo&nbsp; 4200&nbsp;Gen10 Plus Backplane Expander Firmware</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;0.39<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Supplemental Update / Online ROM Flash Component for Ubuntu&nbsp;&ndash; HPE Apollo&nbsp; 4200&nbsp;Gen10 Plus Backplane Expander Firmware</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;0.39<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Supplemental Update / Online ROM Flash Component for Ubuntu&nbsp;&ndash; HPE Apollo&nbsp; 4200&nbsp;Gen10 Plus Backplane Expander Firmware</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;0.39<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"3343764","DateModified":"2025-08-06T02:29:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-1.1/CP068087.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-1.1/Eaglescanyon-Release-0.39.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068087.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068087.scexe"],"MD5Sum":"35b10e264296b1d97c8eb6c14a5affbf","Name":"firmware-smartarray-f36d4ef431_0.39-1.1_amd64.deb","Release":"2025-08-06T07:23:23","Revision":"","SHA1Sum":"58cb3ec8ecd96c9b7ebadb4e246bff89193506f5","SHA256Sum":"f9a34cb516e0bb828d3401fe79873dff88a8dfc88391b7a038ce790d8b17a041","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"Installation":{"Command":"CP068087.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Procedure to update firmware from Ubuntu operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension.</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run launch_sum.sh script which is found in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Procedure to update firmware from Ubuntu operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension.</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run launch_sum.sh script which is found in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"cn","Value":"<p><strong>Procedure to update firmware from Ubuntu operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension.</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run launch_sum.sh script which is found in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Ubuntu – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"Online ROM Flash Component for Ubuntu – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"cn","Value":"Online ROM Flash Component for Ubuntu – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-09-05T07:29:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial Build</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Initial Build</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial Build</p>","Fixes":"","Lang":"cn"}],"Version":"0.39"}],"SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"96a3a2df5fdd4882ab04e83b1ab5fe31"}]},{"ProductId":"1174220fe8354722a040071980d1eb37","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2025."},{"Lang":"ja","Value":"This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2025."},{"Lang":"cn","Value":"This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"2458472","DateModified":"2025-11-17T01:28:15","FileList":["cp068345.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"cbfbe293a4eee4b279629b83ab25c17c","Name":"cp068345.exe","Release":"2025-11-17T01:13:42","Revision":"","SHA1Sum":"675e00a3fbd12c7fcd13cfd7857fdfd29df55067","SHA256Sum":"a76617d1c182e46a4dc2ba86dfb34f67d51600a76e0d9978ff2a67c79d010593","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.7.26882.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox WinOF2 Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"Mellanox WinOF2 Driver for Microsoft Windows Server 2025"},{"Lang":"cn","Value":"Mellanox WinOF2 Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30117","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30040","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30102","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30047","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30116","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30052","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0012","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30012","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0007","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30007","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-13T02:39:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"en"},{"Enhancements":"<p>Windows上のDOCAテレメトリライブラリに対するサポートが追加されました。</p>","Fixes":"<ul><li>この製品では、ファームウェアが機能していない場合にサスペンド/再開プロセス中にBSODが発生する可能性がある問題が修正されました。</li><li>この製品では、アダプターが無効化されている場合、マルチセグメントPCIマシン上で「Mlx5Cmd -Stat」が物理的な位置情報を誤って表示する問題を修正しました。</li><li>この製品では、イベント399に誤った情報が表示される問題が修正されました。</li><li>この製品は、VMQ/SR-IOVモードで動作するアダプター上でpktmonを有効化または無効化する際に、エラーイベント410および304が発生する問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"cn"}],"Version":"25.4.26768.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"cn"}],"Version":"25.7.26882.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fac75eb70c924ea69774e71cf8fa763a"}]},{"ProductId":"58e30c6460374d34ab64c2a8547dafe2","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-2CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_2CQDA2_O_SEC_4p90_PLDMoMCTP_80020EF7.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-15928086000e","Version":"4.90"}]},"MinimumActiveVersion":"4.20","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-2CQDA2 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-2CQDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-2CQDA2 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80020EF7</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-2CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター</td><td>80020EF7</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.9と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80020EF7</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"}],"Files":[{"Bytes":"10526344","DateModified":"2025-12-18T07:09:22","FileList":["HPE_E810_2CQDA2_O_SEC_4p90_PLDMoMCTP_80020EF7.HPb","HPE_E810_2CQDA2_O_SEC_4p90_PLDMoMCTP_80020EF7.xml","payload.json"],"MD5Sum":"03b742e73735289e42e744850ee5acee","Name":"HPE_E810_2CQDA2_O_SEC_4p90_PLDMoMCTP_80020EF7.fwpkg","Release":"2025-12-18T07:06:09","Revision":"B","SHA1Sum":"80438b013552d8f1623bf09bf226ba0f1cc089f5","SHA256Sum":"da72728269365867ba6eef0af0a89ca9c94f23ae04cc19a1bac6e496f7409236","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-15928086000e"],"TypeOfChange":"1","Version":"4.90"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-2CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-18T06:15:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"},{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"}],"SWKeys":[{"Name":"INTEL_E810_2CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"d71c77fdf6f747e895937e6e280cbe25"}]},{"ProductId":"ab1694a2c3b34d68b6e9d41c15960bf5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1039008","DateModified":"2025-11-16T04:27:16","FileList":["cp069550.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs68x64.cat","ixs68x64.din","ixs68x64.inf","ixs68x64.sys","ixsmsg.dll","nicdrvr.dll"],"MD5Sum":"905ee767dca6fb40edf2924339a3e4dd","Name":"cp069550.exe","Release":"2025-11-16T04:13:05","Revision":"B","SHA1Sum":"992fe0d542e99ec44af8166c0d379c7c7e39cf93","SHA256Sum":"4acd8f6e53a5866b135665830f22c7e1e9387aef8458a577d7f6d79ce4114643","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecee44d472"],"TypeOfChange":"1","Version":"4.1.254.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixs Driver for Windows Server 2019"},{"Lang":"ja","Value":"Windows Server 2019用HPE Intel ixsドライバー"},{"Lang":"cn","Value":"HPE Intel ixs Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、新しいファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"4.1.254.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、新しいファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"4.1.254.0"}],"SWKeys":[{"Name":"ixs68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"139342fddb704f7abff074902a8fb7b8"}]},{"ProductId":"b3a8e7e2c4ea466a9b404955f474449e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"MinimumActiveVersion":"5.3.0","Package":{"Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"cn","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"ja","Value":"Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の認証情報を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerバージョン8.0.0以降および展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"9810278","DateModified":"2026-01-13T22:54:33","FileList":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/lib/.build-id","./usr/lib/.build-id/57","./usr/lib/.build-id/57/374c6b2b55c3ea60f4ebaa7dfd1667b9b459f6","./usr/lib/.build-id/f9","./usr/lib/.build-id/f9/4e6eff9d7193146d9f263bcf5ff79200232910","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"MD5Sum":"8c1aa9b856f7aabddba58604b583b721","Name":"sut-6.5.0-3.linux.x86_64.rpm","Release":"2026-01-14T04:50:07","Revision":"","SHA1Sum":"f9b42d0636e8226e4cd65e56c435cfd5a39b56d0","SHA256Sum":"55e242e69e3d86e2c7a66618e181edda97ae69a858e2745ca11e8d05be1bcdfb","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"6.5.0.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"},{"Lang":"ja","Value":"<p>RPMパッケージをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。\"rpm -Uvh hpsut-XXX.x86_64.rpm\"とタイプしてインストールします。</p>"},{"Lang":"cn","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Integrated Smart Update Tools for Linux x64"},{"Lang":"cn","Value":"Integrated Smart Update Tools for Linux x64"},{"Lang":"ja","Value":"Integrated Smart Update Tools for Linux x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-01T09:51:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"6.4.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"6.5.0.0"}],"SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HP Smart Update Tools (HP SUT)"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"R13","Model":"HPE ProLiant Compute DL384 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1466d379f5f84ee4914865b141c07a38"}]},{"ProductId":"35452d3049b54455b15816bf1978a61f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB014000JXUCC"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JXUCC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB014000JXUCC&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB014000JXUCC&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"22258630","DateModified":"2025-03-06T13:53:16","FileList":["/CP065932_BUILD_4.data","/CP065932.vmexe64","/CP065932.vmfile","/CP065932_VMw.zip","/CP065932.xml","/payload.json","/CP065932_VMw.zip/index.xml","/CP065932_VMw.zip/vendor-index.xml","/CP065932_VMw.zip/metadata.zip","/CP065932_VMw.zip/vib20/CP065932/HPE_bootbank_CP065932_HPD4.4-1OEM.800.1.0.20613240.vib","/CP065932_VMw.zip/metadata.zip/vendor-index.xml","/CP065932_VMw.zip/metadata.zip/vmware.xml","/CP065932_VMw.zip/metadata.zip/vibs/CP065932--4097815081717471274.xml","/CP065932_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065932_HPD4.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"6adf8f070f79051b4430222ea26c9178","Name":"CP065932.zip","Release":"2025-03-06T13:52:32","Revision":"C","SHA1Sum":"32cc08b5c3715aa860d128c3043864f438c16ef0","SHA256Sum":"655cb4b38576e4c95c29e0fce45ac550992440b2cbf14d14406483a6b2384104","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065932","Version":"HPD4.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JXUCC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JXUCCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000JXUCC","TargetGUID":"4d2340a5-3042-3431-3030-304a58554343","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:21:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"be0a1042d0204a86ac4cfc2eeaf6b666"}]},{"ProductId":"17666522baed46e695f28d4315d6fdb8","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1908-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Windows Operating Systems."},{"Lang":"ja","Value":"このパッケージには、Windowsオペレーティングシステム上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"}],"Files":[{"Bytes":"22612352","DateModified":"2025-12-01T10:45:44","FileList":["cp069151.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1908-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"53ce9e71ec944e7a3ac82ab312a17c43","Name":"cp069151.exe","Release":"2025-12-01T10:43:32","Revision":"","SHA1Sum":"30d1a1cc780c1b94146e90534fbcfa65821a2232","SHA256Sum":"735ef31254d01d50b2822dcffd186aa8ac3bc15d36cd2e39ea275741480f3014","Size":"21MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.0.9"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p> From that drive and directory, execute the downloaded file.</p><p> Click the Install button to proceed with the installation.</p>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p> そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> [インストール]ボタンをクリックして、インストールを開始してください。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"Lang":"ja","Value":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（Windows x64）"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T09:20:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1904:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>P11338-B21(HPE Ethernet 10Gb 2ポート548SFP+アダプター)</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1904:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul>","Lang":"cn"}],"Version":"1.0.0.8"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>バージョン14.32.1908には、以下の新機能と変更が含まれます。</strong></p><ul><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。</li></ul>","Fixes":"<p><strong>バージョン14.32.1908には修正は含まれていません。</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"cn"}],"Version":"1.0.0.9"}],"SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"2777f6fda48945ed81cea9765028c6c0"}]},{"ProductId":"58259b45dec7469580dfbddb76171768","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf-kmp-default) to (igb-ixgbevf-default). Now we revert this change from (ixgbevf-kmp-default) to (<strong>hp</strong>-ixgbevf-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-ixgbevf-kmp-default and ixgbevf-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbevf-kmp-default and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>  このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-ixgbevf-kmp-default）から（igb-ixgbevf-default）に変更されました。この変更を（ixgbevf-kmp-default）から（<strong>hp</strong>-ixgbevf-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-ixgbevf-kmp-defaultとixgbevf-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e ixgbevf-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf-kmp-default) to (igb-ixgbevf-default). Now we revert this change from (ixgbevf-kmp-default) to (<strong>hp</strong>-ixgbevf-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-ixgbevf-kmp-default and ixgbevf-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbevf-kmp-default and then install the updated RPM.</p>"}],"Files":[{"Bytes":"81561","DateModified":"2025-09-16T07:24:38","FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbevf","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"MD5Sum":"dc32a3b4422ffcb81b5e96e11bef61b1","Name":"hp-ixgbevf-kmp-default-5.1.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-09-16T07:17:23","Revision":"","SHA1Sum":"641526e46dc58c0c2dcbe573a769f69d74575939","SHA256Sum":"2e6f615e6c883efd71d5e1210ea0872a56568980e6f3fbd7c7a28d9f1bb524a0","Size":"79KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"TypeOfChange":"1","Version":"5.1.6-1"},{"Bytes":"82173","DateModified":"2025-09-16T07:28:53","FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"MD5Sum":"6d71acfd58f3fa3e5574be82b3a9b213","Name":"hp-ixgbevf-kmp-default-5.1.6_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-09-16T07:17:23","Revision":"","SHA1Sum":"cfc5c444b9d26fbb13c681417577b860a1be4760","SHA256Sum":"a8700dc4cfdea3b24d745456a3f8135fd6dfcf12b821f957a61a81f9b13bfcfe","Size":"80KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"TypeOfChange":"1","Version":"5.1.6-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"57ad","SubDev":"00FF","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad808600ff","Type":"pci","Ven":"8086"},{"Dev":"57B1","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57b180860003","Type":"pci","Ven":"8086"},{"Dev":"57AD","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad80860003","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-12T09:33:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now adds support for E610 device.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品では、E610デバイスのサポートが追加されました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now adds support for E610 device.</p>","Fixes":"","Lang":"cn"}],"Version":"5.1.4-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"5.1.6-1"}],"SWKeys":[{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"485902bc894d43778f6106101e7d3c4d"}]},{"ProductId":"6f1e3dc0362445eba42c38fd34e5d638","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JEFRB and MM2000JEFRC Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JEFRB and MM2000JEFRC Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18925796","DateModified":"2025-03-06T06:42:10","FileList":["/CP066004_BUILD_4.data","/CP066004.vmexe64","/CP066004.vmfile","/CP066004_VMw.zip","/CP066004.xml","/payload.json","/CP066004_VMw.zip/index.xml","/CP066004_VMw.zip/vendor-index.xml","/CP066004_VMw.zip/metadata.zip","/CP066004_VMw.zip/vib20/CP066004/HPE_bootbank_CP066004_HPDA.4-1OEM.800.1.0.20613240.vib","/CP066004_VMw.zip/metadata.zip/vendor-index.xml","/CP066004_VMw.zip/metadata.zip/vmware.xml","/CP066004_VMw.zip/metadata.zip/vibs/CP066004-3420236790855351228.xml","/CP066004_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066004_HPDA.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"77ff39c6dd222313622b84c1579c18e6","Name":"CP066004.zip","Release":"2025-03-06T06:41:20","Revision":"E","SHA1Sum":"c9b52dc775b0bff3f2dce31efe0f51218c03bbf6","SHA256Sum":"a3ae20ec5c54071af83ccd26cb573c668b69fa31f56903d1ea1e3fcccfb1cd13","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"TypeOfChange":"1","Version":"HPDA","VibList":[{"Name":"CP066004","Version":"HPDA.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042542.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JEFRB and MM2000JEFRC Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MM1000JEFRB","TargetGUID":"002340a5-4d00-314d-3030-304a45465242","Type":"sas"},{"Id":"MM2000JEFRC","TargetGUID":"002340a5-4d00-324d-3030-304a45465243","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:02:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPDA"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"MM1000JEFRB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MM2000JEFRC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f38300f9f29d40558648ce3d9c0e2ab3"}]},{"ProductId":"01e0939311154208bbd5b8d9e5157a9c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."},{"Lang":"cn","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."},{"Lang":"ja","Value":"Smart Storage Administrator CLI（SSACLI）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるコマンドラインベースのディスク構成プログラムです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[{"Lang":"en","Value":"<p>To enter the&nbsp;SSA&nbsp;CLI console type: ssacli</p><p>Commands can also be executed from outside the&nbsp;SSA&nbsp;CLI console using the syntax: ssacli</p><p>Type &quot;ssacli help&quot; or type &quot;help&quot; at the CLI prompt for usage details.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>SSA CLIコンソールに入るには、ssacliとタイプします。</p><p>SSA CLIコンソール以外からでも、構文ssacliを使用してコマンドを実行することができます。</p><p>使用方法について詳しくは、\"ssacli help\"とタイプするか、CLIプロンプト内で\"help\"とタイプしてください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To enter the&nbsp;SSA&nbsp;CLI console type: ssacli</p><p>Commands can also be executed from outside the&nbsp;SSA&nbsp;CLI console using the syntax: ssacli</p><p>Type &quot;ssacli help&quot; or type &quot;help&quot; at the CLI prompt for usage details.</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"9174912","DateModified":"2025-12-18T05:31:15","FileList":["cp069346.xml","cpqsetup.exe","cp_data.xml","genericmsi.dll","SSACLI66080_X64.msi"],"MD5Sum":"8829f6923cc7b9e9da991613a2eba827","Name":"cp069346.exe","Release":"2025-12-18T05:29:16","Revision":"","SHA1Sum":"b519710d82d0132416051dbfb0cca2c088e5aec6","SHA256Sum":"4b3dccc1725bed4aa02663afccc9832dc83947df3668bd2deef2aa28d1510acc","Size":"8MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9f015b42"],"TypeOfChange":"1","Version":"6.60.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) CLI for Windows 64ビット for Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:15:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Windowsツール証明書の期限切れの問題を修正します。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"6.50.13.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>RC drop 6.60.8.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RC drop 6.60.8.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>RC drop 6.60.8.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.60.8.0"}],"SWKeys":[{"Name":"ssacli.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssacli\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ce76dc9b3af14383b0c03a0be0be0bb7"}]},{"ProductId":"6a847a9d6bca429f84558286ffec6636","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"},{"Lang":"ja","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"},{"Lang":"cn","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Supplemental Update / Online ROM Flash Component for Ubuntu&nbsp;&ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;1.27<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Supplemental Update / Online ROM Flash Component for Ubuntu&nbsp;&ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;1.27<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Supplemental Update / Online ROM Flash Component for Ubuntu&nbsp;&ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;1.27<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"3331784","DateModified":"2025-08-06T02:18:30","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/CP068086.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/Capitola-Release-1.27.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068086.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068086.scexe"],"MD5Sum":"9814324026cb06d7b004196c8916fbab","Name":"firmware-smartarray-7b5e8400dd_1.27-1.1_amd64.deb","Release":"2025-08-06T07:06:58","Revision":"","SHA1Sum":"b0792f3cc85876c1220b5750189bc455a18d7550","SHA256Sum":"5c67f15e23186d49a0043afe62d1410e1d97a3155e8efe22a5dad04181540b0c","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"Installation":{"Command":"CP068086.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Procedure to update firmware from Ubuntu operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension.</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run launch_sum.sh script which is found in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Procedure to update firmware from Ubuntu operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension.</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run launch_sum.sh script which is found in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"cn","Value":"<p><strong>Procedure to update firmware from Ubuntu operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension.</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run launch_sum.sh script which is found in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Ubuntu – HPE Apollo 2000 Gen10 Plus Backplane Expander FW"},{"Lang":"ja","Value":"Online ROM Flash Component for Ubuntu – HPE Apollo 2000 Gen10 Plus Backplane Expander FW"},{"Lang":"cn","Value":"Online ROM Flash Component for Ubuntu – HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Id":"Apollon2800Gen10Plus","TargetGUID":"","Type":"agp"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-09-05T07:26:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial Build</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Initial Build</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial Build</p>","Fixes":"","Lang":"cn"}],"Version":"1.27"}],"SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"84fa069df01d4e558127828cc2b6fecb"}]},{"ProductId":"9f1ff08535434ba0ad3d9924079f9908","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-305958554a42","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-305958554a43","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-305958554a44","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-305958554855","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-305958554856","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-305958554a41","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルにファームウェアを提供します：MO001600YXUJB、MO003200YXUJC、MO006400YXUJD、VO001920YXUHU、VO003840YXUHVおよびVO007680YXUJA"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2516501","DateModified":"2025-07-02T13:04:20","FileList":["Kioxia_CM7_KACM7ALFHPK4.HPb","Kioxia_CM7_KACM7ALFHPK4.xml","payload.json"],"MD5Sum":"902769a3f27c4f315060039a6db0a5ac","Name":"Kioxia_CM7_KACM7ALFHPK4.fwpkg","Release":"2025-07-02T13:01:48","Revision":"","SHA1Sum":"9214dd9e0e54a062fd7748d07e1d71b056e47554","SHA256Sum":"5a40fd4dc0a7c09d71013355d6c5ead183b9a9a0d22710e9c8c15f13401d0701","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3130-3630-305958554a42","4d2340a5-304f-3330-3230-305958554a43","4d2340a5-304f-3630-3430-305958554a44","562340a5-304f-3130-3932-305958554855","562340a5-304f-3330-3834-305958554856","562340a5-304f-3730-3638-305958554a41"],"TypeOfChange":"1","Version":"HPK4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"},{"Lang":"ja","Value":"ドライブ用ユニバーサルファームウェアパッケージ - MO001600YXUJB、MO003200YXUJC、MO006400YXUJD、VO001920YXUHU、VO003840YXUHVおよびVO007680YXUJA"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO001600YXUJB","TargetGUID":"4d2340a5-304f-3130-3630-305958554a42","Type":"nvme"},{"Id":"MO003200YXUJC","TargetGUID":"4d2340a5-304f-3330-3230-305958554a43","Type":"nvme"},{"Id":"MO006400YXUJD","TargetGUID":"4d2340a5-304f-3630-3430-305958554a44","Type":"nvme"},{"Id":"VO001920YXUHU","TargetGUID":"562340a5-304f-3130-3932-305958554855","Type":"nvme"},{"Id":"VO003840YXUHV","TargetGUID":"562340a5-304f-3330-3834-305958554856","Type":"nvme"},{"Id":"VO007680YXUJA","TargetGUID":"562340a5-304f-3730-3638-305958554a41","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-02T08:09:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for PCIe link length drop in AMD x2 system configuration</li><li>Fix for drive detection after hot re-insert on Windows</li><li>Fix for other regular FW patch release</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>AMD x2システム構成でのPCIeリンク長の低下の修正</li><li>Windowsでのホット再挿入後のドライブ検出の修正</li><li>その他の定期的なFWパッチリリースの修正</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for PCIe link length drop in AMD x2 system configuration</li><li>Fix for drive detection after hot re-insert on Windows</li><li>Fix for other regular FW patch release</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"MO001600YXUJB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200YXUJC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400YXUJD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920YXUHU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840YXUHV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680YXUJA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"518ac76b543d46469d9245292ee12137"}]},{"ProductId":"74593c8509e24398998a42d78a910462","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A47_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33594444","DateModified":"2026-01-13T02:47:55","FileList":["A47_4.00_01_09_2026.signed.flash","A47_4.00_01_09_2026.xml","payload.json"],"MD5Sum":"a1f00eec7e9fd76cbd3ec73ea4fd28b6","Name":"A47_4.00_01_09_2026.fwpkg","Release":"2026-01-13T02:44:44","Revision":"","SHA1Sum":"00f59cbef620c2e3dfd1bddb0d7b527f6f6f52c5","SHA256Sum":"a581f2830ab48687f06c032b49e0d51209a19583a6a381eb6e4f0b10958660fc","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus(A47) サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:35:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.90_10-03-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"d1c7195cfc1e42d2ab2132f505542218"}]},{"ProductId":"11f86ddaaa3742028089d7f3e7f71098","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8002-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8002"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8002-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8002"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8002-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 9.0"},{"Lang":"ja","Value":"このパッケージは、VMware ESXi 9.0上でHPE NVIDIA VPI (EthernetおよびInfinibandモードで動作) ConnectX6アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"}],"Files":[{"Bytes":"23940780","DateModified":"2025-10-15T10:24:18","FileList":["/CP069136.vmexe64","/CP069136.vmfile","/CP069136.xml","/CP069136_VMw.zip","/payload.json","/CP069136_VMw.zip/index.xml","/CP069136_VMw.zip/vendor-index.xml","/CP069136_VMw.zip/metadata.zip","/CP069136_VMw.zip/vib20/CP069136/HPE_bootbank_CP069136_1.0.2-1OEM.900.0.24755229.vib","/CP069136_VMw.zip/metadata.zip/vendor-index.xml","/CP069136_VMw.zip/metadata.zip/vmware.xml","/CP069136_VMw.zip/metadata.zip/vibs/CP069136--7175204229592131219.xml","/CP069136_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069136_1.0.2-1OEM.900.0.24755229.xml"],"MD5Sum":"57657cc7605258592ca0dbde8b67cb69","Name":"CP069136.zip","Release":"2025-10-15T10:25:43","Revision":"","SHA1Sum":"3d9dfb52f712f60eabaff64de8b80c43637c745f","SHA256Sum":"68bbf825434056d3eba1d4d641b2e89dd3ef86c8cc74642a7fd52e9059b4da0b","Size":"22MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP069136","Version":"1.0.2-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報 (rootまたは管理者ユーザー名およびパスワード) を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記</strong>：SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションにアダプターの正確な名前が表示されません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください： </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します  <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。 (アップデートを適用するにはrootユーザーとしてログインする必要があります)  <br />Smartコンポーネントを一時ディレクトリに置きます (例：/tmp/) <br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 9.0"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ (ESXi 9.0) for HPE NVIDIA  VPI (EthernetおよびInfinibandモード) ConnectX6デバイス - VMware ESXi 9.0"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"13000"},"SupportedDevices":[{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-09T06:35:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが20.43.2566にアップデートされました。</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-HDATアダプター- P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-ECATアダプター- P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe3 x16 MCX653106A-ECATアダプター- P06251-B21</li></ul><p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"1.0.2"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"1.0.3"}],"SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cb93a69eaa354131be22ecdff471aeb3"}]},{"ProductId":"5b139cd72d0b4c89818f276c3a1dce8c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"9894828","DateModified":"2025-09-21T20:25:41","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/CP068912.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/MPK78H5Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068912.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068912.scexe"],"MD5Sum":"25be31f459bdb5cf1f81e8f597a6c29a","Name":"firmware-hdd-e320db791d-MPK78H5Q-6.1.x86_64.rpm","Release":"2025-09-22T01:15:18","Revision":"F","SHA1Sum":"dba0b59c9a99ba00af0a63b0796a04f0b4707d1b","SHA256Sum":"6f0f7ddbf954db11bfac41e02bda371373371c79711631462591ac9ec6bbe591","Size":"9MB","TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報:</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXL515THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3135-54486d0092b3","Type":"nvme"},{"Id":"MZXL512THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3132-544895b51a17","Type":"nvme"},{"Id":"MZXL57T6HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3754-364820f1a5c1","Type":"nvme"},{"Id":"MZXL56T4HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3654-34482ab7fb8f","Type":"nvme"},{"Id":"MZXL53T8HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-38483310a47b","Type":"nvme"},{"Id":"MZXL53T2HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-324884d9e9f5","Type":"nvme"},{"Id":"MZXL51T9HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-3948e450274f","Type":"nvme"},{"Id":"MZXL51T6HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-36487a9b1618","Type":"nvme"},{"Id":"MZXL5960HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3936-304894dc03d2","Type":"nvme"},{"Id":"MZXL5800HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3830-3048d90154e8","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:52:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"MPK78H5Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"}],"SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1070be9bbbed4c4086fa6ad6742ae22a"}]},{"ProductId":"a8ea930bfde1449ab4444eb61f65be31","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8002-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8002"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1908-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1908"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1908-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Windows Operating Systems."},{"Lang":"ja","Value":"このパッケージには、Windowsオペレーティングシステム上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"}],"Files":[{"Bytes":"28334888","DateModified":"2025-12-01T12:27:02","FileList":["cp068980.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1908-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1908-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_35_8002-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"f6d14c1e6e5f88d25510ecba70695458","Name":"cp068980.exe","Release":"2025-12-01T12:24:49","Revision":"","SHA1Sum":"bbdbac350df3385b110b47d3b613074964c7c045","SHA256Sum":"5b55b4ed0cf8708547b2af6fd8123f3a1e3eecf779e1bced4012607b6ff442e6","Size":"27MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.0.14"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p> From that drive and directory, execute the downloaded file.</p><p> Click the Install button to proceed with the installation.</p>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p> そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> [インストール]ボタンをクリックして、インストールを開始してください。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for Mellanox Open Ethernet cards"},{"Lang":"ja","Value":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（Windows x64）"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-29T06:25:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4506:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>P21930-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4121A-XCATアダプター)</li><li>P11341-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4621A-ACAB OCP3アダプター)</li></ul><p> </p><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>P21927-B21（HPE Ethernet 100Gb 2ポートQSFP28 MCX516A-CCHTアダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4506で修正されました：</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4506:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.0.13"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1908にアップデートされました。</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2ポートSFP+ MCX4121A-XCATアダプター)</li><li>P11341-B21 (HPE Ethernet 10Gb 2ポートSFP+ MCX4621A-ACAB OCP3アダプター)</li></ul><p> </p><p><strong>次のデバイス用のファームウェアが16.35.8002にアップデートされました。</strong></p><ul><li>P21927-B21（HPE Ethernet 100Gb 2ポートQSFP28 MCX516A-CCHTアダプター）<br /> </li></ul><p><strong>バージョン14.32.1908には、以下の新機能と変更が含まれます。</strong></p><ul><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /><br /> </li></ul><p><strong>バージョン16.35.8002には、以下の新機能と変更が含まれます。</strong></p><ul><li>ファームウェア例外パス処理のパフォーマンスが向上し、構成されたSR-IOVインスタンスの数の増加をより適切にサポートできるようになりました。</li><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。</li></ul>","Fixes":"<p><strong>バージョン14.32.1908には修正は含まれていません。</strong><br /><br /><strong>以下の問題点がバージョン16.35.8002で修正されました。</strong></p><ul><li>FWがCQ回復モードに入った後、ファームウェアはPFの正しいCQをスキャンできませんでした。その結果、PFのCQが回復されませんでした。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.0.14"}],"SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"b3480297df324a12bff00057bd25edf5"}]},{"ProductId":"ef1bc7c351c4439cbfa57f557a362e59","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE90X0_KPE9010IHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304b59585051","Version":"HPK2"},{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE90X0_KPE9010IHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3936-304b59585141","Version":"HPK2"},{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE90X0_KPE9010IHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3130-3932-304b59585142","Version":"HPK2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VR000480KYXPQ, VR000960KYXQA and VR001920KYXQB"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: VR000480KYXPQ, VR000960KYXQA and VR001920KYXQB"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VR000480KYXPQ, VR000960KYXQA and VR001920KYXQB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5754639","DateModified":"2025-06-13T05:12:18","FileList":["payload.json","SKHynix_PE90X0_KPE9010IHPK2.HPb","SKHynix_PE90X0_KPE9010IHPK2.xml"],"MD5Sum":"f3cca0de8343c8a81b8c068a843717bd","Name":"SKHynix_PE90X0_KPE9010IHPK2.fwpkg","Release":"2025-06-13T05:10:23","Revision":"","SHA1Sum":"f461ec6e0f8a64f10da8fd26cddc1fcd1c7913f5","SHA256Sum":"82cadf1c03809a3b5ec339fa89d12b19ac22fa4b968d0c5f64d79834310ca591","Size":"5MB","TargetGUIDs":["562340a5-3052-3030-3438-304b59585051","562340a5-3052-3030-3936-304b59585141","562340a5-3052-3130-3932-304b59585142"],"TypeOfChange":"1","Version":"HPK2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  VR000480KYXPQ, VR000960KYXQA and VR001920KYXQB"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  VR000480KYXPQ, VR000960KYXQA and VR001920KYXQB"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  VR000480KYXPQ, VR000960KYXQA and VR001920KYXQB"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VR000480KYXPQ","TargetGUID":"562340a5-3052-3030-3438-304b59585051","Type":"nvme"},{"Id":"VR000960KYXQA","TargetGUID":"562340a5-3052-3030-3936-304b59585141","Type":"nvme"},{"Id":"VR001920KYXQB","TargetGUID":"562340a5-3052-3130-3932-304b59585142","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-13T03:45:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul>","Lang":"cn"}],"Version":"HPK2"}],"SWKeys":[{"Name":"VR000480KYXPQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR000960KYXQA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR001920KYXQB","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"ef508d000e044335b7e14985704ba1f8"}]},{"ProductId":"f68792033b364ab4b274dc849cf93dea","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.23"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 8.0 and 9.0."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 8.0 and 9.0."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 8.0 and 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"10803678","DateModified":"2025-03-07T08:18:19","FileList":["/CP064261_BUILD_40.data","/CP064261.vmexe64","/CP064261.vmfile","/CP064261_VMw.zip","/CP064261.xml","/payload.json","/CP064261_VMw.zip/index.xml","/CP064261_VMw.zip/vendor-index.xml","/CP064261_VMw.zip/metadata.zip","/CP064261_VMw.zip/vib20/CP064261/HPE_bootbank_CP064261_4.20.0.40-1OEM.900.0.24580437.vib","/CP064261_VMw.zip/metadata.zip/vendor-index.xml","/CP064261_VMw.zip/metadata.zip/vmware.xml","/CP064261_VMw.zip/metadata.zip/vibs/CP064261--2746712027800506905.xml","/CP064261_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064261_4.20.0.40-1OEM.900.0.24580437.xml"],"MD5Sum":"c401d90383179cc3433da02d84be1053","Name":"CP064261.zip","Release":"2025-03-07T08:17:45","Revision":"","SHA1Sum":"4381c112510a3a8edf1ecd58a82dc59637ac4e29","SHA256Sum":"4a56ddfdd7dbeee9447bfa8df8ee588b5888a09b65d8119a70026e7fe804f04d","Size":"10MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"4.20.0","VibList":[{"Name":"CP064261","Version":"4.20.0.40-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Manual installation instructions:</strong></p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul style=\"list-style-type:circle\"><li>For ESXi 7.0 targets: esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>For ESXi 6.x targets: esxcli software vib install -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install -d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul style=\"list-style-type:circle\"><li>Execute command: ./Execute_Component -s</li></ul></li><li>Clean up the Smart Component:<ul style=\"list-style-type:circle\"><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul style=\"list-style-type:square\"><li>For ESXi 7.0 targets: esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>For ESXi 6.x targets: esxcli software vib remove -n CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>手動によるインストール手順：</strong></p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul style=\"list-style-type:circle\"><li>ESXi 7.0ターゲットの場合：esxcli  software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li><li>ESXi 6.xターゲットの場合：esxcli software vib install -d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul style=\"list-style-type:circle\"><li>次のコマンドを実行します：./Execute_Component -s</li></ul></li><li>Smartコンポーネントをクリーンアップします。<ul style=\"list-style-type:circle\"><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul style=\"list-style-type:square\"><li>ESXi 7.0ターゲットの場合：esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>ESXi 6.xターゲットの場合：esxcli software vib remove -n CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Manual installation instructions:</strong></p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul style=\"list-style-type:circle\"><li>For ESXi 7.0 targets: esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>For ESXi 6.x targets: esxcli software vib install -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install -d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul style=\"list-style-type:circle\"><li>Execute command: ./Execute_Component -s</li></ul></li><li>Clean up the Smart Component:<ul style=\"list-style-type:circle\"><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul style=\"list-style-type:square\"><li>For ESXi 7.0 targets: esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>For ESXi 6.x targets: esxcli software vib remove -n CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware"},{"Lang":"cn","Value":"VMware 版 HPE QLogic FastLinQ 在线固件升级实用程序"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-11-25T08:18:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"4.19.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"4.20.0"}],"SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d03f21f7e00b40b4996d662ba82ab674"}]},{"ProductId":"0883e4abd7344c9b834b5e5585107933","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID® Gen11コントローラー製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2711388","DateModified":"2025-09-17T08:13:57","FileList":["./opt/MegaRAID/storcli/storcli","./opt/MegaRAID/storcli/storcli64","./usr/share/smartupdate/storcli/component.xml"],"MD5Sum":"012647485736c68bc67b6c1d3677cc6d","Name":"storcli-007.3212.0000.0000-1.noarch.rpm","Release":"2025-09-17T08:11:03","Revision":"B","SHA1Sum":"eaca853f39aaa3e09239a6c43b5537a73cf47b2e","SHA256Sum":"0480160f2b9f91f2aad8d894579cd8f4f9fbc0c8a6622680864637ff3fe80b97","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"007.3212.0000.0000"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>STORCLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of STORCLI installed on the system, please use &quot;rpm -e storcli-&lt;version&gt;.noarch&quot; to remove it first.</li><li>To install the StorCLI RPM, run the rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;StorCLI-x.xx-x.noarch.rpm&gt; command.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/MegaRAID/storcli and the executable name is storcli64.</li></ul>"},{"Lang":"ja","Value":"<ul><li>STORCLIはRed Hat Package Manager（RPM）パッケージを用いて配布されます。</li><li>古いバージョンのSTORCLIがシステムにインストールされている場合、\"rpm -e storcli-<version>.noarch\"を使用して最初にそれを削除してください。</li><li>StorCLI RPMをインストールするには、rpm  -Uvh --oldpackage --replacefiles –replacepkgs <StorCLI-x.xx-x.noarch.rpm>コマンドを実行します。</li><li>RPMに関する詳細については \"man rpm\" と入力します。</li><li>ソフトウェアは/opt/MegaRAID/storcliにあり、実行可能ファイル名はstorcli64です。</li></ul>"},{"Lang":"cn","Value":"<ul><li>STORCLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of STORCLI installed on the system, please use &quot;rpm -e storcli-&lt;version&gt;.noarch&quot; to remove it first.</li><li>To install the StorCLI RPM, run the rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;StorCLI-x.xx-x.noarch.rpm&gt; command.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/MegaRAID/storcli and the executable name is storcli64.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit (for Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator StorCLI for Linux 64ビット (for Gen10 PlusおよびGen11コントローラー)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit (for Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T07:08:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"cn"}],"Version":"007.3212.0000.0000"},{"ReleaseNotes":[{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"cn"}],"Version":"007.3212.0000.0000"}],"SWKeys":[{"Name":"storcli","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d6104339182e406d9e164d67a885c451"}]},{"ProductId":"02a1f5d0f0e244c0b4c2ace636d0f60b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB004000GWKGV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6385242","DateModified":"2025-09-17T12:29:08","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/CP068844.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/HVLAnAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068844.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068844.scexe"],"MD5Sum":"af232dd503ade0f368be55e9e62763c2","Name":"firmware-hdd-ca21e169e2-HPG1-14.1.x86_64.rpm","Release":"2025-09-17T17:19:05","Revision":"N","SHA1Sum":"9002b37e58ce5b91e87a6352ae81ee708e9de659","SHA256Sum":"01fde7034f962600272c1a449a433db225539453b6dafe05879ae28bfdc723a3","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP041494.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWKGV Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB004000GWKGV ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000GWKGV","TargetGUID":"4d2340a5-3042-3430-3030-3047574b4756","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T18:35:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7b3cf9c7563743daa6b562147e8d59c4"}]},{"ProductId":"a4dfe483f7df4c3993a498bb13f08613","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57414 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957414N4140HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41596","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957414N4140HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957414N4140HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Version":"235.1.164.14"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"1384938","DateModified":"2025-12-11T09:27:20","FileList":["BCM235.1.164.14_BCM957414N4140HC.HPb","BCM235.1.164.14_BCM957414N4140HC.xml","payload.json"],"MD5Sum":"9894014e2ad2587838ea05ea574fbef0","Name":"BCM235.1.164.14_BCM957414N4140HC.fwpkg","Release":"2025-12-11T09:24:08","Revision":"","SHA1Sum":"f68ac5f63dadff7ddb2e7ff74589ee5dae94bad3","SHA256Sum":"36731439815a771ff73d7df29dcaf532d889be66427685e5aa92c39bf873acc9","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM57414 OCP3 adapter"},{"Lang":"ja","Value":"Broadcom Firmware Package for BCM57414 OCP3 adapter"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM57414 OCP3 adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-11T08:10:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"BCM_NXE_957414OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"06b7d7577bbf4c3cbb07c25bf7795353"}]},{"ProductId":"9681dd7da3ad4cfa8b9f5d2fa3efb5ac","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1079424","DateModified":"2025-11-14T08:26:18","FileList":["cp069545.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"ef56b162a5f4ad35e80667a3bddf08db","Name":"cp069545.exe","Release":"2025-11-14T08:12:02","Revision":"B","SHA1Sum":"c498c79eb1547160c6711959e62f3f62de7048e9","SHA256Sum":"2b221c1557aa85cabc16e6d1feb002a2b5f526e102ff0d556887575e26d5524c","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.1.24.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i350 Driver for Windows Server 2025"},{"Lang":"ja","Value":"Intel i350 Driver for Windows Server 2025"},{"Lang":"cn","Value":"Intel i350 Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"cn"}],"Version":"14.1.24.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"cn"}],"Version":"14.1.24.0"}],"SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755374"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"bc3de517782147afa79bbf057ec34708"}]},{"ProductId":"8e9f61780275418686c8b0a671e012c9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0</li></ul>"}],"Files":[{"Bytes":"27942847","DateModified":"2025-03-06T10:52:39","FileList":["/CP065982_BUILD_3.data","/CP065982.vmexe64","/CP065982.vmfile","/CP065982_VMw.zip","/CP065982.xml","/payload.json","/CP065982_VMw.zip/index.xml","/CP065982_VMw.zip/vendor-index.xml","/CP065982_VMw.zip/metadata.zip","/CP065982_VMw.zip/vib20/CP065982/HPE_bootbank_CP065982_HPG3.3-1OEM.800.1.0.20613240.vib","/CP065982_VMw.zip/metadata.zip/vendor-index.xml","/CP065982_VMw.zip/metadata.zip/vmware.xml","/CP065982_VMw.zip/metadata.zip/vibs/CP065982--2943951110476072958.xml","/CP065982_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065982_HPG3.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"4ab74db02baaf82f9e0170eea5ef19b6","Name":"CP065982.zip","Release":"2025-03-06T10:51:53","Revision":"C","SHA1Sum":"6e0434a924b6470c6165dc7f44910cc4f05617c8","SHA256Sum":"d013f91302adc0d3beabe5fc4b96820642de24884e6b03ae900570d11384b7b2","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP065982","Version":"HPG3.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043256.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK000480GZCNE","TargetGUID":"562340a5-304b-3030-3438-30475a434e45","Type":"sata"},{"Id":"VK000960GZCNF","TargetGUID":"562340a5-304b-3030-3936-30475a434e46","Type":"sata"},{"Id":"VK001920GZCNH","TargetGUID":"562340a5-304b-3130-3932-30475a434e48","Type":"sata"},{"Id":"VK003840GZCNK","TargetGUID":"562340a5-304b-3330-3834-30475a434e4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:17:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b140902a90e9402ca1580bc2b9bc489b"}]},{"ProductId":"3fba85b34f854c9b9b5bb51030ba5e41","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000JWKGN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"20671336","DateModified":"2025-03-06T16:28:04","FileList":["/CP065983_BUILD_3.data","/CP065983.vmexe64","/CP065983.vmfile","/CP065983_VMw.zip","/CP065983.xml","/payload.json","/CP065983_VMw.zip/index.xml","/CP065983_VMw.zip/vendor-index.xml","/CP065983_VMw.zip/metadata.zip","/CP065983_VMw.zip/vib20/CP065983/HPE_bootbank_CP065983_HPD2.3-1OEM.800.1.0.20613240.vib","/CP065983_VMw.zip/metadata.zip/vendor-index.xml","/CP065983_VMw.zip/metadata.zip/vmware.xml","/CP065983_VMw.zip/metadata.zip/vibs/CP065983-8248823532782371284.xml","/CP065983_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065983_HPD2.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"7ed2ba6e8a5acbeaa1f5a0750fb46bf6","Name":"CP065983.zip","Release":"2025-03-06T16:27:16","Revision":"F","SHA1Sum":"984a5a16236880aee2169a924f0a4e29ee1e4344","SHA256Sum":"ce723400c762662d23d9cd525b93983ae90cd6803d4e5639b6ec6c588fcbb00b","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP065983","Version":"HPD2.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041489.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000JWKGNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB006000JWKGN","TargetGUID":"4d2340a5-3042-3630-3030-304a574b474e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:18:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"22eb5327aa084ebaa74d6463bbe06c9d"}]},{"ProductId":"d4e991bf139c45c8a6f5a9b30e1a9d04","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U50_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34046038","DateModified":"2026-01-12T02:07:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.54_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.54_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.54_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.54_2026_01_09-1.1/CP070304.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.54_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.54_2026_01_09-1.1/U50_2.54_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.54_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.54_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.54_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070304.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070304.scexe"],"MD5Sum":"b4b0ec3de35bf70ec187faf7a73f6712","Name":"firmware-system-u50-2.54_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-12T08:00:09","Revision":"","SHA1Sum":"c1e6de316324406712ea609e4a36aa085c2f4b3b","SHA256Sum":"e1e3d80756fb072d496fcd374fcdc6b6444e41ff7487fa87bc48b7c6a8902aff","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus（U50）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T07:59:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ee5fd5e77ca345c49b566fce80d6df80"}]},{"ProductId":"151904788c644c28a2c281d63b7a3b35","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"3740264","DateModified":"2025-08-03T01:00:35","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-1.1/CP067327.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-1.1/GPM1643ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067327.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067327.scexe"],"MD5Sum":"1c66c673a8f04df1f774f1c548efd14c","Name":"firmware-hdd-35fd24601f_0HPD5-1.1_amd64.deb","Release":"2025-08-03T05:52:00","Revision":"","SHA1Sum":"d3a13dc6151b5682339a09a4039ba7b72ecae10f","SHA256Sum":"09cb9f21640ac841fa9978f94f0717d1ecde7d83d36625ca807ef673a591cdd0","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP043252.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO015360JWZJN","TargetGUID":"562340a5-304f-3531-3336-304a575a4a4e","Type":"sas"},{"Id":"VO007680JWZJL","TargetGUID":"562340a5-304f-3730-3638-304a575a4a4c","Type":"sas"},{"Id":"VO003840JWZJK","TargetGUID":"562340a5-304f-3330-3834-304a575a4a4b","Type":"sas"},{"Id":"VO001920JWZJH","TargetGUID":"562340a5-304f-3130-3932-304a575a4a48","Type":"sas"},{"Id":"VO000960JWZJF","TargetGUID":"562340a5-304f-3030-3936-304a575a4a46","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:47:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"527908168aca403da34cfd18a15ef35a"}]},{"ProductId":"4ec88340a2ce4a0da239c4051a775bd6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3416160","DateModified":"2025-11-15T14:15:20","FileList":["4IYRHPG7.bin","cp068622.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"d7c007e2df7a0f167266b66dca62102e","Name":"cp068622.exe","Release":"2025-11-15T14:09:01","Revision":"E","SHA1Sum":"ad106791b45f10a79b7c526616713b7e295fab9a","SHA256Sum":"d4c113c5e17a27eaaca1febc2db02d7696c64c54b7717aa0b28e5a5786209e85","Size":"3MB","TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK003840GWTTD","TargetGUID":"562340a5-304b-3330-3834-304757545444","Type":"sata"},{"Id":"MK003840GWTTN","TargetGUID":"4d2340a5-304b-3330-3834-30475754544e","Type":"sata"},{"Id":"VK001920GWTTC","TargetGUID":"562340a5-304b-3130-3932-304757545443","Type":"sata"},{"Id":"MK001920GWTTL","TargetGUID":"4d2340a5-304b-3130-3932-30475754544c","Type":"sata"},{"Id":"VK000960GWTTB","TargetGUID":"562340a5-304b-3030-3936-304757545442","Type":"sata"},{"Id":"MK000960GWTTK","TargetGUID":"4d2340a5-304b-3030-3936-30475754544b","Type":"sata"},{"Id":"VK000480GWTTA","TargetGUID":"562340a5-304b-3030-3438-304757545441","Type":"sata"},{"Id":"MK000480GWTTH","TargetGUID":"4d2340a5-304b-3030-3438-304757545448","Type":"sata"},{"Id":"VK000240GWTSV","TargetGUID":"562340a5-304b-3030-3234-304757545356","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T07:22:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG7"}],"SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e4aa692ceed2495eac575e38697200dd"}]},{"ProductId":"e760dc1509734b53830053c8a8b00097","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"769429","DateModified":"2025-11-18T07:02:59","FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/elx-lpfc","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"MD5Sum":"a0e6fb8910177ac6b6869dcecb042a68","Name":"kmod-elx-lpfc-14.4.731.6-1.rhel9u6.x86_64.rpm","Release":"2025-11-18T06:58:05","Revision":"","SHA1Sum":"82879839004fb8d3fe5df44cb6e783c1683aaf8d","SHA256Sum":"a2688243fbbf3de25374ae386a39ec3c7f5cc6dbaf2bb44ca842620410212c9a","Size":"751KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.6"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.559.0-1.rhel9u2.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.559.0-1.rhel9u2.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.559.0-1.rhel9u2.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 9 Server Update 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 Server Update 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 9 Server Update 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-26T05:09:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10.0</p><p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.731.6"}],"SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c3c7312c567d4cc79e5681530cda29cb"}]},{"ProductId":"b50552ebf09d445294b0b81e162643cf","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX631102 10/25GbE 2p SFP28 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_46_3048-MCX631102AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30012","Version":"26.46.3048"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージ - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2ポートSFP28アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE&nbsp;(P42044-B21)</td><td>26.46.3048</td><td>MT_0000000575</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE&nbsp;(P42044-B21)</td><td>26.46.3048</td><td>MT_0000000575</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE&nbsp;(P42044-B21)</td><td>26.46.3048</td><td>MT_0000000575</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7275188","DateModified":"2025-10-09T08:07:16","FileList":["26_46_3048-MCX631102AS-ADA_Ax.pldm.signed","26_46_3048-MCX631102AS-ADA_Ax.pldm.xml","payload.json"],"MD5Sum":"ac3ba0044f62df7ea9db60e49010ce36","Name":"26_46_3048-MCX631102AS-ADA_Ax.pldm.fwpkg","Release":"2025-10-09T08:05:13","Revision":"","SHA1Sum":"a5ef0d8f9873c2a19466a40cd561ef24bb33f096","SHA256Sum":"1f26544b5940a8d3006fe3b41117219dfccd4f34bddbd92db7107883e441b113","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f15b30012"],"TypeOfChange":"1","Version":"26.46.3048"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3.  iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ(FWPKG)- Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2ポートSFP28アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-30T08:01:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>No new features and changes have been included in version 26.45.1020.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 26.45.1020:</strong></p><ul><li>Configuring PHY_RATE_MASK for 10G in NV settings incorrectly disabled 10G capabilities.</li><li>RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port&#39;s MAC.</li></ul>","Lang":"en"},{"Enhancements":"<p>セキュリティ強化の機能強化 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。<br /> </p><p><strong>バージョン26.45.1020には、新機能も変更も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン26.45.1020で修正されました：</strong></p><ul><li>NV設定で10GのPHY_RATE_MASKを構成すると、10G機能が誤って無効になります。</li><li>任意の宛先MACアドレスを持つRTTパケットが、有効な宛先MACを持つとして誤って処理されていました。新しいファームウェアでは、宛先MACがポートのMACと一致しない場合、RTTパケットが破棄されるようになりました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>No new features and changes have been included in version 26.45.1020.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 26.45.1020:</strong></p><ul><li>Configuring PHY_RATE_MASK for 10G in NV settings incorrectly disabled 10G capabilities.</li><li>RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port&#39;s MAC.</li></ul>","Lang":"cn"}],"Version":"26.45.1020"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;26.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;26.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;26.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"cn"}],"Version":"26.46.3048"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX631102AS-ADAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"b6f79883124748f38807582b5faf7f63"}]},{"ProductId":"849be1890758471abae8ed641e7b3fb4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"SSDPEL1K375GA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"E2010603.bin","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"E2010603"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Disk"},{"Lang":"ja","Value":"ファームウェア - ストレージ ディスク"},{"Lang":"cn","Value":"固件 - 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the drive model: SSDPEL1K375GA that can be installed directly on any HPE Edgeline e920 Systems running a supported Linux Operating System."},{"Lang":"ja","Value":"このSmartコンポーネントは、SSD PEL1K375GAモデルのドライブに対応するファームウェアを提供します。このファームウェアは、サポートされているLinuxオペレーティングシステムを実行しているHPE Edgeline e920システムに直接インストールできます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"25056971","DateModified":"2026-01-28T20:28:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/CP060386.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/intelmas","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/intelmas/intelmas.zip","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP060386.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP060386.scexe"],"MD5Sum":"27070fa261a496dc3eb3ab9a6679cb57","Name":"firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1.x86_64.rpm","Release":"2026-01-29T02:15:36","Revision":"A","SHA1Sum":"d7c842815b6666c2eec2f0adeafe435f4fc918de","SHA256Sum":"d4b57fa432793af357c31ad29889afda5cf4c7d10543d175327f62f65ea7b8f9","Size":"23MB","TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"E2010603"}],"Installation":{"Command":"setup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To install firmware from Linux operating system on target server:</strong></p><p>&nbsp;</p><p>Execute the below commands:</p><p>&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change(cd) to the directory you see in the previous step and run hpsetup by typing &lsquo;./setup&rsquo; at the command prompt.</p><p><strong>Note</strong>: Installing the firmware rpm package (rpm -ivh) does not update the firmware. &nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed using SUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"},{"Lang":"ja","Value":"<p><strong>To install firmware from Linux operating system on target server:</strong></p><p>&nbsp;</p><p>Execute the below commands:</p><p>&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change(cd) to the directory you see in the previous step and run hpsetup by typing &lsquo;./setup&rsquo; at the command prompt.</p><p><strong>Note</strong>: Installing the firmware rpm package (rpm -ivh) does not update the firmware. &nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed using SUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Intel Optane SSD Flash Component for Linux - SSDPEL1K375GA Drive"},{"Lang":"ja","Value":"オンラインIntel Optane SSDフラッシュコンポーネントfor Linux - SSDPEL1K375GAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"9000"},"SupportedDevices":[{"Id":"SSDPEL1K375GA","TargetGUID":"532340a5-4453-4550-4c31-4b3337354741","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-04-06T12:35:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added SUSE Linux 15 for COM support</p>","Fixes":"<p>Added SUSE Linux 15 for COM support</p>","Lang":"en"},{"Enhancements":"<p>SUSE Linux 15のCOMサポートを追加しました</p>","Fixes":"<p>SUSE Linux 15のCOMサポートを追加しました</p>","Lang":"ja"},{"Enhancements":"<p>Added SUSE Linux 15 for COM support</p>","Fixes":"<p>Added SUSE Linux 15 for COM support</p>","Lang":"cn"}],"Version":"E2010603"}],"SWKeys":[{"Name":"SSDPEL1K375GA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H10","Model":"HPE Edgeline e920d Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f457b16828314c279f84d52e2451956b"}]},{"ProductId":"1188e33080924486b998a030d43acf6f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1547496","DateModified":"2025-11-16T12:54:13","FileList":["cp069527.xml","cpqsetup.exe","cp_data.xml","i40eb.cat","i40eb.inf","i40eb.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"7594f3b0caa5d9fa14be14f94911ffa0","Name":"cp069527.exe","Release":"2025-11-16T12:40:32","Revision":"B","SHA1Sum":"736879ebfe1449beddd7c63268bfbdab2e8ceb71","SHA256Sum":"639e0478260d3ac4a7c321eb3b3a48258a1e317b52dbab63afc7126495f94164","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"TypeOfChange":"1","Version":"1.22.75.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40eb Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Intel i40ebドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Intel i40eb Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:41:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"cn"}],"Version":"1.22.75.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"cn"}],"Version":"1.22.75.0"}],"SWKeys":[{"Name":"i40eb.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\i40eb.inf_amd64_e2860b19128ec940"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a42e1a033bf148858813a4a46baf61b9"}]},{"ProductId":"b27e4086749b43a09022b1ccf9b6e0c0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe) to (ixgbe). Now we revert this change from (ixgbe) to (<strong>hp</strong>-ixgbe).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-ixgbe and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbe and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-ixgbe）から（ixgbe）に変更されました。この変更を（ixgbe）から（<strong>hp</strong>-ixgbe）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-ixgbeとkmod-ixgbeareはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-ixgbeによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe) to (ixgbe). Now we revert this change from (ixgbe) to (<strong>hp</strong>-ixgbe).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-ixgbe and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbe and then install the updated RPM.</p>"}],"Files":[{"Bytes":"371879","DateModified":"2025-09-15T15:18:27","FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-ixgbe","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/cf","./usr/lib/.build-id/cf/430f09f570f43e7fecbeccb884e3797b455910","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"MD5Sum":"a443679f8401e897c2de2a11c9778d77","Name":"kmod-hp-ixgbe-6.2.5-1.rhel9u6.x86_64.rpm","Release":"2025-09-15T15:11:12","Revision":"","SHA1Sum":"67adeefb26b54cd9846f077a6e01e3ac68f99010","SHA256Sum":"e612d812ebfda80094ce9e841389ec1e5112ea2f433ecc0f0ad31fe7aa9ca1d6","Size":"363KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"TypeOfChange":"1","Version":"6.2.5-1"},{"Bytes":"372028","DateModified":"2025-09-15T15:22:43","FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-ixgbe","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/74","./usr/lib/.build-id/74/5bc20f915205b537777cca47998eb3687779a8","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"MD5Sum":"1b904020ae2b9b876806cf4d0458c532","Name":"kmod-hp-ixgbe-6.2.5-1.rhel9u5.x86_64.rpm","Release":"2025-09-15T15:11:12","Revision":"","SHA1Sum":"7862934525a18883e85720b7b779ec28fb450a5f","SHA256Sum":"f0c0be473e3cd14af9e291a67ee1f733943ee9aee51e300e2f9c525eeb263e6a","Size":"363KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"TypeOfChange":"1","Version":"6.2.5-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"57ad","SubDev":"00FF","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad808600ff","Type":"pci","Ven":"8086"},{"Dev":"57B1","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57b180860003","Type":"pci","Ven":"8086"},{"Dev":"57AD","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad80860003","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-12T09:29:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product now adds support for E610 device.</li><li>This product now supports Red Hat Enterprise Linux 9.6.</li><li>This product adds support for NVM update during FW recovery.</li></ul>","Fixes":"<ul><li>This product fixes remove 128 CPUs limit for XDP.</li><li>This product fixes stop setting carrier on while the adapter is down.</li><li>This product fixes use netdev-&gt;fcoe_mtu when required.</li><li>Known issue: Firmware OROM version displays as &quot;0.0.0&quot; via &quot;ethtool -i&quot;.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品では、E610デバイスのサポートが追加されました。</li><li>この製品は、現在Red Hat Enterprise Linux 9.6をサポートします。</li><li>この製品は、FWリカバリ中のNVMアップデートのサポートを追加します。</li></ul>","Fixes":"<ul><li>この製品は、XDPの128CPU制限を修正します。</li><li>この製品は、アダプターがダウンしている間、キャリアをオンにするのを停止するように修正します。</li><li>この製品は、必要に応じて netdev->fcoe_mtu を使用するように修正します。</li><li>既知の問題: 「ethtool -i」を実行すると、ファームウェア OROM バージョンが「0.0.0」と表示されます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product now adds support for E610 device.</li><li>This product now supports Red Hat Enterprise Linux 9.6.</li><li>This product adds support for NVM update during FW recovery.</li></ul>","Fixes":"<ul><li>This product fixes remove 128 CPUs limit for XDP.</li><li>This product fixes stop setting carrier on while the adapter is down.</li><li>This product fixes use netdev-&gt;fcoe_mtu when required.</li><li>Known issue: Firmware OROM version displays as &quot;0.0.0&quot; via &quot;ethtool -i&quot;.</li></ul>","Lang":"cn"}],"Version":"6.1.5-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"6.2.5-1"}],"SWKeys":[{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fdcef100ed52453cb0ab7e4f96ab96f2"}]},{"ProductId":"070f2ccb66ec4478ba85a2e3d9712434","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;&nbsp;EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;&nbsp;EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"19639050","DateModified":"2025-03-06T07:31:33","FileList":["/CP066000_BUILD_2.data","/CP066000.vmexe64","/CP066000.vmfile","/CP066000_VMw.zip","/CP066000.xml","/payload.json","/CP066000_VMw.zip/index.xml","/CP066000_VMw.zip/vendor-index.xml","/CP066000_VMw.zip/metadata.zip","/CP066000_VMw.zip/vib20/CP066000/HPE_bootbank_CP066000_HPDB.2-1OEM.800.1.0.20613240.vib","/CP066000_VMw.zip/metadata.zip/vendor-index.xml","/CP066000_VMw.zip/metadata.zip/vmware.xml","/CP066000_VMw.zip/metadata.zip/vibs/CP066000-1605751100554710823.xml","/CP066000_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066000_HPDB.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"7fdd95d35ecb715d4581eebd31af6ac2","Name":"CP066000.zip","Release":"2025-03-06T07:30:40","Revision":"B","SHA1Sum":"c3bc54c9a33b81af21cc746b566eff9c4bb472a8","SHA256Sum":"63b541f0f46929b9e30c7e1072283683999495004df2bf838fad7edd96ecfe29","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP066000","Version":"HPDB.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040541.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that&nbsp; CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that&nbsp; CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EH000300JWCPK","TargetGUID":"452340a5-3048-3030-3330-304a5743504b","Type":"sas"},{"Id":"EH000600JWCPL","TargetGUID":"452340a5-3048-3030-3630-304a5743504c","Type":"sas"},{"Id":"EH000900JWCPN","TargetGUID":"452340a5-3048-3030-3930-304a5743504e","Type":"sas"},{"Id":"EH000900JXLVU","TargetGUID":"452340a5-3048-3030-3930-304a584c5655","Type":"sas"},{"Id":"EH000300JXLVR","TargetGUID":"452340a5-3048-3030-3330-304a584c5652","Type":"sas"},{"Id":"EH000600JXLVT","TargetGUID":"452340a5-3048-3030-3630-304a584c5654","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:52:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d3127bf38a094ef284bcda3b9b102157"}]},{"ProductId":"570234d74f264fc1985961d91a29c03a","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE e910 QSFP+ 4x10G Network Riser","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Backplane_4x10G_NCSI_4p30_80001A42.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37ce80860000","Version":"1.2684"},{"DeviceName":"HPE e910 1G RJ45 Network Rsr","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37d180860000","Version":"1.2684"},{"DeviceName":"HPE e910 2p 10GbE SFP+ Mod","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37d380860000","Version":"1.2684"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This smart component provides NIC firmware that can be installed directly on the HPE Edgeline e910/e910t System running a supported Windows Operating System installed in HPE Edgeline EL8000/EL8000t chassis."},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Edgeline EL8000/EL8000tシャーシに設置されたサポート対象のWindowsオペレーティングシステムを実行するHPE Edgeline e910/e910tシステムに直接インストールできるNICファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11008248","DateModified":"2026-01-15T01:56:48","FileList":["BootIMG.FLB","cp070383.xml","cpqsetup.exe","ilorest_chif.dll","Immediate_offset_1.txt","Immediate_offset_2.txt","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","iSCSI.txt","iv.txt","LBG_B2_Backplane_4x10G_NCSI_4p30_80001FC8.bin","LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001FE8.bin","nvmupdatew64e.exe","OCP_Configuration.txt","payload.json","payload_version.txt","QSFP.cfg","RJ45.cfg","SFP.cfg","version.txt"],"MD5Sum":"9f74f27df54d9e2ffe30d45374812c5f","Name":"cp070383.exe","Release":"2026-01-15T01:49:18","Revision":"B","SHA1Sum":"e2fcbfeb56241899a7330bcb8ed4511a18f3c3e8","SHA256Sum":"fdf19b3027d88f840dfd5d9db30a427869cbc289e135d263f985966b819f1e3d","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-37ce80860000","a6b1a447-382a-5a4f-8086-37d180860000","a6b1a447-382a-5a4f-8086-37d380860000"],"TypeOfChange":"1","Version":"4.30"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed from HPSUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをインストールするには、以下の手順に従ってください：</strong></p><p> </p><p>CP0xxxxx.exeをダブルクリックします。</p><p>または </p><p>スタートメニューからコマンドプロンプトを開きます<br />コマンドプロンプトで、CP0xxxxx.exeがコピーされているパスに移動します<br />exeファイルの実行例を以下に示します：<br />    <br />    >> CP0xxxxx.exe</p><p> </p><p><strong>Service Pack for EdgelineからSmart Update Managerを使用してファームウェアをインストールするには、次の手順に従います：</strong></p><p> </p><p>このSmartコンポーネントは、Service Pack for Edgeline（SPE）でも利用可能であり、HPSUMからインストールできます</p><p> </p><p>インストール手順についてはSUMユーザーガイドを、詳細についてはSPEリリースノートを参照してください。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Edgeline X722 NIC Firmware Component for Microsoft Windows"},{"Lang":"ja","Value":"HPE Edgeline X722 NICファームウェアコンポーネントfor Microsoft Windows"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"10000"},"SupportedDevices":[{"Dev":"37D3","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37D380860000","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37D180860000","Type":"pci","Ven":"8086"},{"Dev":"37CE","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37CE80860000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-15T01:18:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"4.30"},{"ReleaseNotes":[{"Enhancements":"<p>HPE signing key cert&nbsp;update</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>HPE signing key cert&nbsp;update</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>HPE signing key cert&nbsp;update</p>","Fixes":"","Lang":"cn"}],"Version":"4.30"}],"SWKeys":[{"Name":"x722","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"66b90de597c94dbfaf7482bc5137b3f6"}]},{"ProductId":"2b1131d5128b46ff8528f19d5b030560","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8002"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1908"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 9.0."},{"Lang":"ja","Value":"このパッケージには、ESXi 9.0上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"}],"Files":[{"Bytes":"24791254","DateModified":"2025-10-14T07:09:48","FileList":["/payload.json","/CP068979_VMw.zip","/CP068979.xml","/CP068979.vmexe64","/CP068979.vmfile","/CP068979_VMw.zip/index.xml","/CP068979_VMw.zip/vendor-index.xml","/CP068979_VMw.zip/metadata.zip","/CP068979_VMw.zip/vib20/CP068979/HPE_bootbank_CP068979_1.0.2-1OEM.900.0.24755229.vib","/CP068979_VMw.zip/metadata.zip/vendor-index.xml","/CP068979_VMw.zip/metadata.zip/vmware.xml","/CP068979_VMw.zip/metadata.zip/vibs/CP068979--404681921638168640.xml","/CP068979_VMw.zip/metadata.zip/bulletins/Smart-Component-CP068979_1.0.2-1OEM.900.0.24755229.xml"],"MD5Sum":"7a13b7247ad9c56e49619b9496370a52","Name":"CP068979.zip","Release":"2025-10-14T07:09:44","Revision":"","SHA1Sum":"f704b1a82f3c4be80929ebcb2648db8dd7ea904e","SHA256Sum":"40d4c28b5850aeb8d9c48e711e3c152cd488d175d525cf58df0c59cfb8a50a9d","Size":"23MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.2","VibList":[{"Name":"CP068979","Version":"1.0.2-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記</strong>：SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションにアダプターの正確な名前が表示されません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください： </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します  <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for Mellanox Open Ethernet cards"},{"Lang":"ja","Value":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（ESXi 9.0）"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for Mellanox Open Ethernet cards"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-29T06:25:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4506:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>P21930-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4121A-XCATアダプター)</li><li>P11341-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4621A-ACAB OCP3アダプター)</li></ul><p> </p><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>P21927-B21（HPE Ethernet 100Gb 2ポートQSFP28 MCX516A-CCHTアダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4506で修正されました：</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4506:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.2"}],"SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1d4aff589dc546f087c7d4ba74ef9546"}]},{"ProductId":"5d8c4ca5e9ce4b8ab296e754f4544502","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB002000JYDNE and MB004000JYDPB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB002000JYDNEおよびMB004000JYDPB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB002000JYDNE and MB004000JYDPB&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB002000JYDNE and MB004000JYDPB&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4509816","DateModified":"2025-11-16T14:44:17","FileList":["cp068736.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARBPNSD6.rel","setup.dll"],"MD5Sum":"d43e775a5c039f8b9482355f78566320","Name":"cp068736.exe","Release":"2025-11-16T14:39:30","Revision":"B","SHA1Sum":"d2555ff54cbe38ca56f7ae1fcdc9698cc9708ae2","SHA256Sum":"1d8695c16716ee1f7ac34baccdeaa9f78e3bd81d8ba3e1cd872c0b7e993c4db2","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JYDNE and MB004000JYDPB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB002000JYDNEおよびMB004000JYDPBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000JYDPB","TargetGUID":"4d2340a5-3042-3430-3030-304a59445042","Type":"sas"},{"Id":"MB002000JYDNE","TargetGUID":"4d2340a5-3042-3230-3030-304a59444e45","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T05:38:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ファームウェアの変更は、将来のFIPSコードリリースと1つのアサート修正のため調整されました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"cn"}],"Version":"HPD6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>ファームウェアの変更は、将来のFIPSコードリリースと1つのアサート修正のため調整されました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"98f0ab5aa0074cff977bf2a34841783a"}]},{"ProductId":"e33bb1d2f7324af98ab1d5f7897ec4b5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2022用のドライバーを含みます。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2460096","DateModified":"2025-11-17T01:49:16","FileList":["cp068340.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"99dab1f9bf88171c9be075bb95d734ca","Name":"cp068340.exe","Release":"2025-11-17T01:35:00","Revision":"","SHA1Sum":"c644743a7aba532a146fdeea6da540b99ac818d7","SHA256Sum":"0aaf079a03fc4281d061783ab0586440940ab6eb6d4567a9cb2a5974b53c95f6","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.7.26882.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2022"},{"Lang":"cn","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815900246","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-13T02:37:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"en"},{"Enhancements":"<p>Windows上のDOCAテレメトリライブラリに対するサポートが追加されました。</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"ja"},{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"cn"}],"Version":"25.4.26768.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"cn"}],"Version":"25.7.26882.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5d49a6bb54c845babb67cc7c8c4d0128"}]},{"ProductId":"c65e02b4990e43eea4fa2402b45960eb","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000GWWQUおよびMB006000GWWQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4021640","DateModified":"2025-11-17T04:23:15","FileList":["cp068664.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNETG8.rel","setup.dll"],"MD5Sum":"00e7289aa91ae0c73e6d5701e5533014","Name":"cp068664.exe","Release":"2025-11-17T04:17:09","Revision":"D","SHA1Sum":"aca88b0a26fc62634eac587eac2ae310f73622bb","SHA256Sum":"62c04c5d2325ef39b349f4b51f2d77da6d1888819c33b5707ca20796515d8b88","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000GWWQU","TargetGUID":"4d2340a5-3042-3830-3030-304757575155","Type":"sata"},{"Id":"MB006000GWWQT","TargetGUID":"4d2340a5-3042-3630-3030-304757575154","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T10:01:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e9dad618e5094f738b2218775c6075d9"}]},{"ProductId":"9d355b002f0f45528687c05a8ded7241","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5288970","DateModified":"2025-11-11T08:52:11","FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-qla2xxx","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"MD5Sum":"134632963b7ddccb433d9fda7c9193aa","Name":"kmod-qlgc-qla2xxx-10.02.15.00_k1-1.rhel9u6.x86_64.rpm","Release":"2025-11-11T08:45:04","Revision":"","SHA1Sum":"27167f8646c7b3aadca4877b52d5071939260a2d","SHA256Sum":"5d95bbeda6c3f4a83b8b2ae1c95edf537cb466d7807e13c0a3feef53b0fcfa1f","Size":"5MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.15.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel9u6.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel9u6.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel9u6.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 9 update 6 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 update 6 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 9 update 6 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T08:50:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.15.00-k1"}],"SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d9e0960020f5433494a721ef51723b25"}]},{"ProductId":"68526791858d42b69b174ffed2a35fa0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5, 6 and 7 (iLO 5,6 and 7) Embedded Health and Alerting."},{"Lang":"ja","Value":"Agentless Management Service（AMSD）は、Integrated Lights Out 5、6および7（iLO 5、6および7）内蔵ヘルスおよびアラートのサポートを提供します。"},{"Lang":"cn","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5, 6 and 7 (iLO 5,6 and 7) Embedded Health and Alerting."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9756315","DateModified":"2026-01-18T23:35:31","FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/37","./usr/lib/.build-id/37/25579fc7be198abc86d7db5c9e436770c76fc9","./usr/lib/.build-id/37/25579fc7be198abc86d7db5c9e436770c76fc9.1","./usr/lib/.build-id/61","./usr/lib/.build-id/61/7c21f8775dd86efda16c99fbd4d062c27ef23c","./usr/lib/.build-id/61/7c21f8775dd86efda16c99fbd4d062c27ef23c.1","./usr/lib/.build-id/89","./usr/lib/.build-id/89/d2753893a8965cb4e4ce7b70b6bd2ba010ddd2","./usr/lib/.build-id/89/d2753893a8965cb4e4ce7b70b6bd2ba010ddd2.1","./usr/lib/.build-id/94","./usr/lib/.build-id/94/e32b65b3b21ca566eea8c9a7ad3a84ece899df","./usr/lib/.build-id/c2","./usr/lib/.build-id/c2/5804f2d8527491c52576dbe1b406ed082a5f90","./usr/lib/.build-id/c2/5804f2d8527491c52576dbe1b406ed082a5f90.1","./usr/lib/.build-id/c4","./usr/lib/.build-id/c4/9bc400945c328f4bfbd9b22a8819b31bc69b80","./usr/lib/.build-id/c4/9bc400945c328f4bfbd9b22a8819b31bc69b80.1","./usr/lib/.build-id/db","./usr/lib/.build-id/db/e9707290f4e96097fa7cb62e83bb2b58c0fc59","./usr/lib/.build-id/db/e9707290f4e96097fa7cb62e83bb2b58c0fc59.1","./usr/lib/.build-id/ec","./usr/lib/.build-id/ec/5b30145df07b6383a37880d6fe23e91d5e7a5e","./usr/lib/.build-id/ef","./usr/lib/.build-id/ef/70f64a2a4fb8c5527bda8d0c6abc25229d57b2","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"MD5Sum":"fa112c6ac6144076c6515a1f75f7609d","Name":"amsd-4.5.0-2107.2.sles16.x86_64.rpm","Release":"2026-01-19T05:30:38","Revision":"","SHA1Sum":"73d314263a99ae079928a70623d2f7a5d07049c8","SHA256Sum":"999965c2f6c4484a0bd7bae27f6f49b30b9b62e6453ff8b588812ec67604dec3","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.5.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service (iLO5, iLO6, iLO7) for SUSE Linux Enterprise Server 16"},{"Lang":"ja","Value":"Agentless Management Service (iLO5、iLO6、iLO7) for SUSE Linux Enterprise Server 16"},{"Lang":"cn","Value":"Agentless Management Service (iLO5, iLO6, iLO7) for SUSE Linux Enterprise Server 16"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330615903307","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330715903307","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-08T08:56:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"4.4.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"4.5.0"}],"SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U74","Model":"HPE ProLiant Compute XD230 (U74)"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"9199a59d559c451f8beca34fcfa39e63"}]},{"ProductId":"8f4fd902230c4076905c23b7ab80bfdf","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2022で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1246648","DateModified":"2025-11-16T13:36:18","FileList":["cp069525.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"107ab097916cc6d2c0de2eded2ca6a18","Name":"cp069525.exe","Release":"2025-11-16T13:21:18","Revision":"B","SHA1Sum":"80f3101c9c42d7c3ce7f593589f5744ca11a0930","SHA256Sum":"063a16fe77b349f5ebf5a0da73a9e90376f7a2b12a9294190de25d2050ff1810","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.22.88.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40ea Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Intel i40eaドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Intel i40ea Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103C0000","Type":"pci","Ven":"8086"},{"Dev":"158A","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-158A15900000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:00:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"cn"}],"Version":"1.22.88.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"cn"}],"Version":"1.22.88.0"}],"SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ffcf7ca8115e41f8856490ccfd120cc0"}]},{"ProductId":"f74d125372264713b4a9d8ebea70260d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v4.00 (01/09/2026)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34243896","DateModified":"2026-01-13T02:38:09","FileList":["A42_4.00_01_09_2026.signed.flash","cp070342.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"8d20f9a199e53dc1fdc6dc5f5a661b4d","Name":"cp070342.exe","Release":"2026-01-13T02:35:05","Revision":"","SHA1Sum":"93b14f1b6ba179416ec059d92b3e2746c102870c","SHA256Sum":"8551a61d117417628925115d096f4b0a8b110d85ead0463bb7720d5464f97790","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus（A42）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:34:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>改善点/新しい機能:</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。</p><p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.92_11-27-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"50863e760c93433ba9dcb667a5a031db"}]},{"ProductId":"fe217a349ea5432eb992dea833e5cc7b","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 8.0."},{"Lang":"ja","Value":"このパッケージには、ESXi 8.0上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"}],"Files":[{"Bytes":"17569016","DateModified":"2025-10-15T07:53:41","FileList":["/CP069153.vmexe64","/CP069153.vmfile","/CP069153.xml","/CP069153_VMw.zip","/payload.json","/CP069153_VMw.zip/index.xml","/CP069153_VMw.zip/vendor-index.xml","/CP069153_VMw.zip/metadata.zip","/CP069153_VMw.zip/vib20/CP069153/HPE_bootbank_CP069153_1.0.0-8.0.0.21495797.vib","/CP069153_VMw.zip/metadata.zip/vendor-index.xml","/CP069153_VMw.zip/metadata.zip/vmware.xml","/CP069153_VMw.zip/metadata.zip/vibs/CP069153-606309413999435571.xml","/CP069153_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069153_1.0.0-8.0.0.21495797.xml"],"MD5Sum":"65a1163e4e1dd144b43056baa0b9655e","Name":"CP069153.zip","Release":"2025-10-15T07:55:46","Revision":"","SHA1Sum":"23fd7f8feffb2c05d36527ba9d411b2b51768c85","SHA256Sum":"1e403e3aafd01eb27346425848a8cd22ffea8352a28a4c81939070b76748ccd3","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP069153","Version":"1.0.0-8.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します。 <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"Lang":"ja","Value":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ(ESXi 8.0)"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T09:20:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1904:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>P11338-B21(HPE Ethernet 10Gb 2ポート548SFP+アダプター)</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1904:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul>","Lang":"cn"}],"Version":"1.0.2"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"cn"}],"Version":"1.0.3"}],"SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"73330e456c804f06824b8c077e03ce19"}]},{"ProductId":"96d916494e7148b08fda3030539ce372","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.35.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.35.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under VMware VMware vSphere 8.0 and VMware vSphere 9.0 Only."},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 8.0およびVMware vSphere 9.0のみで動作するHPE ProLiant Gen10サーバーシリーズのBroadcom NX1 Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under VMware VMware vSphere 8.0 and VMware vSphere 9.0 Only."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"18543320","DateModified":"2025-10-02T23:51:15","FileList":["/CP069010_BUILD_1.data","/CP069010.vmexe64","/CP069010.vmfile","/CP069010_VMw.zip","/CP069010.xml","/payload.json","/CP069010_VMw.zip/index.xml","/CP069010_VMw.zip/vendor-index.xml","/CP069010_VMw.zip/metadata.zip","/CP069010_VMw.zip/vib20/CP069010/HPE_bootbank_CP069010_1.43.0.1-8.0.0.20613240.vib","/CP069010_VMw.zip/metadata.zip/vendor-index.xml","/CP069010_VMw.zip/metadata.zip/vmware.xml","/CP069010_VMw.zip/metadata.zip/vibs/CP069010--6477493078019629452.xml","/CP069010_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069010_1.43.0.1-8.0.0.20613240.xml"],"MD5Sum":"81b6a4b8dfe532d4e28e69e067f04e12","Name":"CP069010.zip","Release":"2025-10-02T23:50:37","Revision":"","SHA1Sum":"d2c6848cb318d61a0b1b32e2fec4f34ef9983df8","SHA256Sum":"12ad0952485969ca9a15d4ea903d39fc05cb144f1029d26a598589400c972bdc","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"1.43.0","VibList":[{"Name":"CP069010","Version":"1.43.0.1-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility VMware for HPE ProLiant Gen10 server series Only."},{"Lang":"ja","Value":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティfor VMware（HPE ProLiant Gen10サーバーシリーズ専用）。"},{"Lang":"cn","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility VMware for HPE ProLiant Gen10 server series Only."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T06:06:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"1.42.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"1.43.0"}],"SWKeys":[{"Name":"BCM","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"38bb7166f9404eb7986690a259766680"}]},{"ProductId":"75dd01ca72594b0686b5c281ad30ac2a","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4704-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4704"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4704-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4704"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8002"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 9.0"},{"Lang":"ja","Value":"このパッケージは、VMware ESXi 9.0上でHPE Mellanox VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.4704</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.4704</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.8002</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.8002</td><td>HPE0000000022</td></tr></tbody></table>"}],"Files":[{"Bytes":"25571452","DateModified":"2025-10-14T14:35:49","FileList":["/CP069160.xml","/CP069160_VMw.zip","/payload.json","/CP069160.vmexe64","/CP069160.vmfile","/CP069160_VMw.zip/index.xml","/CP069160_VMw.zip/vendor-index.xml","/CP069160_VMw.zip/metadata.zip","/CP069160_VMw.zip/vib20/CP069160/HPE_bootbank_CP069160_1.0.2-1OEM.900.0.24755229.vib","/CP069160_VMw.zip/metadata.zip/vendor-index.xml","/CP069160_VMw.zip/metadata.zip/vmware.xml","/CP069160_VMw.zip/metadata.zip/vibs/CP069160-2197595927021650462.xml","/CP069160_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069160_1.0.2-1OEM.900.0.24755229.xml"],"MD5Sum":"9a8c1d3264c7116144ed6bcf14f6af03","Name":"CP069160.zip","Release":"2025-10-14T14:36:09","Revision":"","SHA1Sum":"c4147549af17f717f54a8ff843c183cb47196302","SHA256Sum":"1de4df6774323d8a3c050ecb6325d36b4f9cba861100ba3b8d9ec8fa047b7f2c","Size":"24MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.2","VibList":[{"Name":"CP069160","Version":"1.0.2-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p>&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.<br />&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記</strong>：SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションにアダプターの正確な名前が表示されません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください： </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します  <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。<br /> </p><p><strong>注記：</strong>CX5ネットワークアダプターファームウェアを16.21.1xxxまたは16.22.1xxx（またはそれ以前）から16.26.1xxx（またはそれ以降）にアップグレードするには、中間ファームウェアバージョンとして16.23.1xxxまたは16.24.1xxxまたは16.25.1xxxを使用してください。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p>&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.<br />&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 9.0"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(ESXi 9.0) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX4およびConnectX5デバイス - VMware ESXi 9.0"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"13000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T14:31:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1ポート840QSFP28アダプター)</li><li>825111-B21(HPE InfiniBand EDR/Ethernet 100Gb 2ポート840QSFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>879482-B21(HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター)</li><li>872726-B21（HPE InfiniBand EDR/Ethernet 100Gb 2ポート 841QSFP28アダプター）</li></ul><p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン12.28.2302には新機能の追加も変更もありません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302に追加された新しい修正はありません。</strong></p><p> </p><p><strong>以下の問題点がバージョン16.35.4506で修正されました。</strong></p><p> </p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.2"}],"SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e5aee7baddc0495db570044c82ecdb7f"}]},{"ProductId":"6f10e85c0a8e4d0f99dcb8584f535fd3","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5132234","DateModified":"2025-09-17T11:59:30","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/CP068860.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/TA14SXn0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068860.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068860.scexe"],"MD5Sum":"6307c21a386da4a03d856ec2a90ebdc3","Name":"firmware-hdd-8d68452816-HPD9-2.1.x86_64.rpm","Release":"2025-09-17T16:49:05","Revision":"B","SHA1Sum":"9eb0fae9635cd26524bd9306f3984ee5126580d7","SHA256Sum":"2cd03f3386457becf4703bee44256b4bc67ec6f6c78978ea485729d1c5cfa3bd","Size":"4MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP041672.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000300JWHPL","TargetGUID":"452340a5-3048-3030-3330-304a5748504c","Type":"sas"},{"Id":"EH000600JWHPN","TargetGUID":"452340a5-3048-3030-3630-304a5748504e","Type":"sas"},{"Id":"EH000900JWHPP","TargetGUID":"452340a5-3048-3030-3930-304a57485050","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:58:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8973e5e1313f4302babcdb7c39e7f423"}]},{"ProductId":"4ecda510f4cf4aef9ac80ad782d1c36e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A41_3.70_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.70 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"18176760","DateModified":"2026-01-14T07:48:44","FileList":["A41_3.70_01_09_2026.signed.flash","cp070200.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"7c66ad4924946f0f83d717a6a35ca1ad","Name":"cp070200.exe","Release":"2026-01-14T07:47:00","Revision":"","SHA1Sum":"501a1a57d958cbbb610bbd506dff800885563cc3","SHA256Sum":"38e71f81fae35bfb4c0132af04a2ec4dcd2130bf2518b49d9ccc6d8da8a31344","Size":"17MB","TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"1","Version":"3.70_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325 Gen10 (A41) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL325 Gen10 (A41) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325 Gen10 (A41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T10:22:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>CVE-2025-3052を軽減するために、デフォルトのセキュアブートDBXをアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。システムROMのこのリビジョンには、AMD第1世代EPYCプロセッサー用のAMDリファレンスコードNaplesPI 1.0.0.Rが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Redfish経由でのBIOS設定の変更が、同じ起動中にBIOSアップデートが実行された場合に、失敗するという問題に対処しました。</p><p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_09-05-2025"},{"ReleaseNotes":[{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.70_01-09-2026"}],"SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"5d6d42aeaf6647f4b93300a058a01ade"}]},{"ProductId":"d780ef43938c40d3a6628583fe2200f7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB016000GWXKK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware revision improves data integrity and reliability by optimizing adjacent track refresh parameters and management of emergency power loss table structure.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in emergency power loss events.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide some minor performance improvements.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware revision improves data integrity and reliability by optimizing adjacent track refresh parameters and management of emergency power loss table structure.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in emergency power loss events.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide some minor performance improvements.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5833285","DateModified":"2025-09-17T12:55:25","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1/CP068861.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1/TAMG08acHPG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068861.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068861.scexe"],"MD5Sum":"25f9320f37fadfc98f67faf7f51b96a8","Name":"firmware-hdd-e4f147cdd2-HPG4-6.1.x86_64.rpm","Release":"2025-09-17T17:46:05","Revision":"F","SHA1Sum":"4dfbb9f36f66d56c373e72d8cd1158d302bd2bc4","SHA256Sum":"c51004ca95b3f8e6ef96feb389efe2207d5bb1d075bfae712cb5ea8850d49fd8","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB016000GWXKK Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB016000GWXKKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB016000GWXKK","TargetGUID":"4d2340a5-3042-3631-3030-304757584b4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:59:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"db2860c512e84e70bbb42ca36725ff41"}]},{"ProductId":"580a9fa720c34c1ab7b8556a4f1de833","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: MB004000JWWQB and MB002000JWWQA Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4478548","DateModified":"2025-08-02T19:58:01","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-1.1/CP067354.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-1.1/SCIMARRNNSD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067354.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067354.scexe"],"MD5Sum":"d8598e0275e26e0092b9afa392fd4a56","Name":"firmware-hdd-adb3ab8147_0HPD8-1.1_amd64.deb","Release":"2025-08-03T00:51:57","Revision":"","SHA1Sum":"f516e8396b80c2a23d91f3b143ba3be50d9fcf58","SHA256Sum":"729120f42dcb49b215c6cbbf734b150fbf8e899c9ba7c7b0b213be5120fbfea2","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP043262.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JWWQB","TargetGUID":"4d2340a5-3042-3430-3030-304a57575142","Type":"sas"},{"Id":"MB002000JWWQA","TargetGUID":"4d2340a5-3042-3230-3030-304a57575141","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:47:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul>","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"65d63a0ca7d3495faf015cbfa213b973"}]},{"ProductId":"7fe88b20c8c948e29d704473f3133fee","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U50_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33599493","DateModified":"2026-01-12T07:59:48","FileList":["payload.json","U50_2.54_01_09_2026.signed.flash","U50_2.54_01_09_2026.xml"],"MD5Sum":"e3b30971559992f9842d9cb5beb9fe65","Name":"U50_2.54_01_09_2026.fwpkg","Release":"2026-01-12T07:57:16","Revision":"","SHA1Sum":"b3119b64cf0b6ba5496ea428a10ea66fd523d18d","SHA256Sum":"f1fa64cdd0e55646f6924a639c6f68a494c2b59c41d8f985e22dab4ed3d4ac6c","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus（U50）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T07:56:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"e344c1b32e984d86bb35e21ac4f1a4ed"}]},{"ProductId":"b1381f6ec67b40269898593ac27aca95","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000JWWQB and MB002000JWWQA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQBおよびMB002000JWWQA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB and MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB and MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"19973771","DateModified":"2025-03-06T09:05:10","FileList":["/CP066009_BUILD_4.data","/CP066009.vmexe64","/CP066009.vmfile","/CP066009_VMw.zip","/CP066009.xml","/payload.json","/CP066009_VMw.zip/index.xml","/CP066009_VMw.zip/vendor-index.xml","/CP066009_VMw.zip/metadata.zip","/CP066009_VMw.zip/vib20/CP066009/HPE_bootbank_CP066009_HPD8.4-1OEM.800.1.0.20613240.vib","/CP066009_VMw.zip/metadata.zip/vendor-index.xml","/CP066009_VMw.zip/metadata.zip/vmware.xml","/CP066009_VMw.zip/metadata.zip/vibs/CP066009--3345376133589604648.xml","/CP066009_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066009_HPD8.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"f83b10a8d86623a241356502055d77ef","Name":"CP066009.zip","Release":"2025-03-06T09:04:26","Revision":"C","SHA1Sum":"ce8036397855a0b2eaecb7bc357ed7b45eb92ca2","SHA256Sum":"83ca550aac24808cb416370db6d31d2ad28fa91812aa41dadab37b785c45f9d7","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP066009","Version":"HPD8.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043266.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000JWWQBおよびMB002000JWWQAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000JWWQB","TargetGUID":"4d2340a5-3042-3430-3030-304a57575142","Type":"sas"},{"Id":"MB002000JWWQA","TargetGUID":"4d2340a5-3042-3230-3030-304a57575141","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:07:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"671351a63ae9400183e592bce3be61ad"}]},{"ProductId":"2433baff8f4443ed8ddae6e9a115bc4d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているIntel i350 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1079032","DateModified":"2025-11-16T06:44:13","FileList":["cp069544.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"121be76a8fb6a017c1f8f296daaeac00","Name":"cp069544.exe","Release":"2025-11-16T06:29:56","Revision":"B","SHA1Sum":"67171d244ac3dbb24e73b7c1c796416ab86b7127","SHA256Sum":"6d0392353e562c2235e18836547ac15bf57fcdb0cf2e7e439f2adf76e2cc5684","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.0.13.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i350 Driver for Windows Server 2022"},{"Lang":"ja","Value":"Intel i350ドライバー for Windows Server 2022"},{"Lang":"cn","Value":"Intel i350 Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"cn"}],"Version":"14.0.13.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"cn"}],"Version":"14.0.13.0"}],"SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755374"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a556c13877764198a3876ee835f32a53"}]},{"ProductId":"b80afd72e0994f04bb439cddf1f507eb","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 9.0."},{"Lang":"ja","Value":"このパッケージには、ESXi 9.0上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1908</td><td>HPE0000000038</td></tr></tbody></table>"}],"Files":[{"Bytes":"16665582","DateModified":"2025-10-15T09:32:32","FileList":["/CP069152.vmfile","/CP069152.xml","/CP069152_VMw.zip","/payload.json","/CP069152.vmexe64","/CP069152_VMw.zip/index.xml","/CP069152_VMw.zip/vendor-index.xml","/CP069152_VMw.zip/metadata.zip","/CP069152_VMw.zip/vib20/CP069152/HPE_bootbank_CP069152_1.0.2-1OEM.900.0.24755229.vib","/CP069152_VMw.zip/metadata.zip/vendor-index.xml","/CP069152_VMw.zip/metadata.zip/vmware.xml","/CP069152_VMw.zip/metadata.zip/vibs/CP069152--4358986581420803025.xml","/CP069152_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069152_1.0.2-1OEM.900.0.24755229.xml"],"MD5Sum":"7e5a50c47ea93d10eba1737b843cf07b","Name":"CP069152.zip","Release":"2025-10-15T09:36:35","Revision":"","SHA1Sum":"dc04abfc43e566cfa6856b6a97ea5e57f18917c7","SHA256Sum":"b8ecdc1582312abae94b001e734719e88182bc1e82885abd43ac0012e78da216","Size":"15MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.2","VibList":[{"Name":"CP069152","Version":"1.0.2-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ（ESXi 9.0）for HPE Ethernet 10Gb 2ポート548SFP+アダプター"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T09:20:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1904:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>P11338-B21(HPE Ethernet 10Gb 2ポート548SFP+アダプター)</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1904:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul>","Lang":"cn"}],"Version":"1.0.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p>","Lang":"cn"}],"Version":"1.0.2"}],"SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e2749e77cde845dc994c9b2d7d66c688"}]},{"ProductId":"2fa1597649f243c092f040a8ecf90232","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"22583517","DateModified":"2025-04-30T11:31:09","FileList":["/CP066971_BUILD_1.data","/CP066971.vmexe64","/CP066971.vmfile","/CP066971_VMw.zip","/CP066971.xml","/payload.json","/CP066971_VMw.zip/index.xml","/CP066971_VMw.zip/vendor-index.xml","/CP066971_VMw.zip/metadata.zip","/CP066971_VMw.zip/vib20/CP066971/HPE_bootbank_CP066971_HPK4.1-8.0.0.20613240.vib","/CP066971_VMw.zip/metadata.zip/vendor-index.xml","/CP066971_VMw.zip/metadata.zip/vmware.xml","/CP066971_VMw.zip/metadata.zip/vibs/CP066971--7720355463295161298.xml","/CP066971_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066971_HPK4.1-8.0.0.20613240.xml"],"MD5Sum":"4c22d2f9cd3247388690ce0a115c44ba","Name":"CP066971.zip","Release":"2025-04-30T11:30:16","Revision":"H","SHA1Sum":"48020a74c1e1fc4dddaada7d776afcd6ee295346","SHA256Sum":"d1224525b9ff04ea06821e2c66c3096a0735155d2a9d39846fbf3e671c20db2b","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4","VibList":[{"Name":"CP066971","Version":"HPK4.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP036934.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul style=\"list-style-type:square\"><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、 VK000960KWWFL、VK001920KWWFN、 VK003840KWWFPおよびVK007860KWWFQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK007680KWWFQ","TargetGUID":"562340a5-304b-3730-3638-304b57574651","Type":"nvme"},{"Id":"MK006400KWWFK","TargetGUID":"4d2340a5-304b-3630-3430-304b5757464b","Type":"nvme"},{"Id":"VK003840KWWFP","TargetGUID":"562340a5-304b-3330-3834-304b57574650","Type":"nvme"},{"Id":"MK003200KWWFH","TargetGUID":"4d2340a5-304b-3330-3230-304b57574648","Type":"nvme"},{"Id":"VK001920KWWFN","TargetGUID":"562340a5-304b-3130-3932-304b5757464e","Type":"nvme"},{"Id":"MK001600KWWFF","TargetGUID":"4d2340a5-304b-3130-3630-304b57574646","Type":"nvme"},{"Id":"VK000960KWWFL","TargetGUID":"562340a5-304b-3030-3936-304b5757464c","Type":"nvme"},{"Id":"MK00800KWWFE","TargetGUID":"002340a5-4b4d-3030-3830-304b57574645","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-25T06:22:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release to include code fix of FW defense algorithm, SN change after assert and POSCAP false alarm.</li></ul>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"648fd11e12d2405e801501f32dffc3dc"}]},{"ProductId":"c73603f447664d53b84b56e38b35a86b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 9 Update 6."},{"Lang":"ja","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 9 Update 6."},{"Lang":"cn","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 9 Update 6."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"44655","DateModified":"2025-12-12T06:56:55","FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/39","./usr/lib/.build-id/39/daf4dc1a2bcb44acf9ed9e78b9c606a0d9dc72","./usr/lib64/libbnxt_re-235.1.164.14.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"MD5Sum":"f65416d0c5932a31357fc63b721a9ec3","Name":"libbnxt_re-235.1.164.14-rhel9u6.x86_64.rpm","Release":"2025-12-12T06:55:04","Revision":"","SHA1Sum":"86b1df2294b878da460731bea4eaaec1acf15b55","SHA256Sum":"4790cbcb43a39059821458d1e8d56b080d3638fd237ffdfef8f2032895dcb4fa","Size":"43KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"ja","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"cn","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 6."},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 6."},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 6."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-12T04:04:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4dd9819d2a844736b3709222a082209e"}]},{"ProductId":"71e64c3d009643d19a9590b92132604d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JXUCC"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JXUCC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;-&nbsp;MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;-&nbsp;MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5365940","DateModified":"2025-08-02T21:28:27","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-1.1/CP067376.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-1.1/PCHFA2BP.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067376.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067376.scexe"],"MD5Sum":"0dbe0ec83d8b43f343510689a8c56d49","Name":"firmware-hdd-017797f12e_0HPD4-1.1_amd64.deb","Release":"2025-08-03T02:19:47","Revision":"","SHA1Sum":"45d84b6f78e28dd6b99cfc84ae325cc1b9de4bc8","SHA256Sum":"2d378bb35fa2bf50bcd33e6701b0a5127b1ad5edcc78a20ec3e029295a637b63","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JXUCC Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JXUCC Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JXUCC","TargetGUID":"4d2340a5-3042-3431-3030-304a58554343","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:01:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e34198bd888c49899c9a9488120492f8"}]},{"ProductId":"77057f17d85c42018e33e3454cf6ece5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This driver package updates OFED Storage Driver for Mellanox Adapters"},{"Lang":"ja","Value":"このドライバーパッケージは、Mellanoxアダプター用のOFEDストレージドライバーをアップデートします"},{"Lang":"cn","Value":"This driver package updates OFED Storage Driver for Mellanox Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"236586080","DateModified":"2026-01-05T05:59:13","FileList":["cp070130.xml","cpqsetup.exe","MlnxDriverInstaller.dll","MLNX_WinOF2-25_4_50020_All_x64.exe"],"MD5Sum":"de18b4e7b9ef3a1b81504e23f876814e","Name":"cp070130.exe","Release":"2026-01-05T05:55:26","Revision":"b","SHA1Sum":"cf523be72c70755e6e2152e62f9b72c5d44366bd","SHA256Sum":"0da7a6a07cfe3079f3ae6d9765ebcfe74288dd620f99bbf900ad42e3aeadcae5","Size":"225MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.4.50020.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p> </p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox OFED Storage Driver for Microsoft Windows Server x64- 2019/2022/2025"},{"Lang":"ja","Value":"HPE Mellanox OFEDストレージドライバーfor Microsoft Windows Server x64- 2019/2022/2025"},{"Lang":"cn","Value":"HPE Mellanox OFED Storage Driver for Microsoft Windows Server x64- 2019/2022/2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"101D","SubDev":"037D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d1590037d","Type":"pci","Ven":"15B3"},{"Dev":"101F","SubDev":"03FE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f159003fe","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-05T05:52:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version 25.4.50020.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン25.4.50020.0にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version 25.4.50020.0</p>","Fixes":"","Lang":"cn"}],"Version":"25.4.50020.0"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version 25.4.50020.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン25.4.50020.0にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version 25.4.50020.0</p>","Fixes":"","Lang":"cn"}],"Version":"25.4.50020.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c80f9df44bb643c7a27894ab5c17cd93"}]},{"ProductId":"787f189347ac420fbe52f5e6292d569d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWKGU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"20644331","DateModified":"2025-03-06T16:35:22","FileList":["/CP065986_BUILD_2.data","/CP065986.vmexe64","/CP065986.vmfile","/CP065986_VMw.zip","/CP065986.xml","/payload.json","/CP065986_VMw.zip/index.xml","/CP065986_VMw.zip/vendor-index.xml","/CP065986_VMw.zip/metadata.zip","/CP065986_VMw.zip/vib20/CP065986/HPE_bootbank_CP065986_HPD2.2-1OEM.800.1.0.20613240.vib","/CP065986_VMw.zip/metadata.zip/vendor-index.xml","/CP065986_VMw.zip/metadata.zip/vmware.xml","/CP065986_VMw.zip/metadata.zip/vibs/CP065986-8432470268618342014.xml","/CP065986_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065986_HPD2.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"72ee3e2881115c5cec547e7b46d23c5b","Name":"CP065986.zip","Release":"2025-03-06T16:34:32","Revision":"F","SHA1Sum":"401f99cd7e109f234e861f2b67e8c9d77bc03a2d","SHA256Sum":"766c65ec647d96187189b33f6d2e559f1b14699ca468cc32f05a393cde19b75f","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP065986","Version":"HPD2.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041492.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000JWKGUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000JWKGU","TargetGUID":"4d2340a5-3042-3430-3030-304a574b4755","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:27:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4adaf2607e844265be77d76abccb13f8"}]},{"ProductId":"8d2bd99747b540d2a364efef8e58a91c","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d815900212","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee15900212","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef15900212","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d81590020c","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d615900230","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de15900230","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d715900211","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec15900211","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed15900211","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d71590020e","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Version":"235.1.164014"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm235.1.164014.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Version":"235.1.164014"}]},"MinimumActiveVersion":"226.1.107000","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Broadcom NetXtreme-E Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 235.1.164014 with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td><td colspan=\"1\" rowspan=\"7\"><p>235.1.164.2</p></td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table></li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 235.1.164014 with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td><td colspan=\"1\" rowspan=\"7\"><p>235.1.164.2</p></td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table></li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 235.1.164014 with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td><td colspan=\"1\" rowspan=\"7\"><p>235.1.164.2</p></td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table></li></ul><p>&nbsp;</p>"}],"Files":[{"Bytes":"8559031","DateModified":"2025-12-13T07:14:14","FileList":["bcm235.1.164014.Optimized.HPb","bcm235.1.164014.Optimized.xml","payload.json"],"MD5Sum":"66db862dc73533ff600994ad39e51650","Name":"bcm235.1.164014.Optimized.fwpkg","Release":"2025-12-13T07:10:15","Revision":"","SHA1Sum":"aacf2f7408cc0ba46702463e58e91af4748c71d4","SHA256Sum":"a848fac305c68b30c196098e46b90767a1f43b2efb9d6bc8b58d638000db185a","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16d615900230","a6b1a447-382a-5a4f-14e4-16de15900230","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"TypeOfChange":"1","Version":"235.1.164014"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong>IMPORTANT ADDITIONAL INFORMATION<em>:</em></strong></p><p><strong><em>(1.)</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Please be noted that firmware package has the minimum version (NVM Image version 216.0.333011).</p></li><li><p>To update to NVM Image version 216.0.333011 (or later), use the &quot;<em>Online Firmware Upgrade Utility</em>&quot; either from the Service Pack for ProLiant (SPP), or download and install the &quot;<em>Online Firmware Upgrade Utility</em>&quot; manually:</p></li><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Service Pack for ProLiant (SPP): </strong><ul style=\"list-style-type:circle\"><li>The Service Pack for ProLiant (SPP) contains the &quot;<em>Online Firmware Upgrade Utility</em>&quot; and the SPP can run in either offline mode or online mode. The firmware update can be performed either by booting from the SPP to update in offline mode or by running the SPP from the current running operating system and update the firmware in online mode.</li></ul></li></ul><p>OR</p><ul><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Online firmware update utility manually: </strong><ul style=\"list-style-type:circle\"><li>Download and install any of the following &quot;Online Firmware Upgrade Utility&quot; component versions (or later):<ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_c9c99d62694e4a6aa418b0a781&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions Version 5.2.3.0 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_2502ce87e3ba481081daea7a6c&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64 Version 1.9.3 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_0d5f5f72693848838710781e5e&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware Version 5.11.6 (or later)</a></li></ul></li></ul></li></ul><p><strong>Note:</strong> After updating to NVM Image version 216.0.333011 (or later) using the &quot;<em>Online Firmware Upgrade Utility</em>&quot;, a reboot is required to enable the new firmware. Once the network adapter has NVM Image version 216.0.333011 (or later) installed and running, the Platform Level Data Model (PLDM) firmware update method (&quot;firmware package&quot; or &quot;fwpkg&quot; file) can be used to update to the latest version.</p><p>&nbsp;</p><p><strong><em>(2.)</em></strong></p><ul style=\"list-style-type:square\"><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, to avoid issues caused by jumping too many versions at once.</li></ul><p style=\"margin-left:40px\">Please refer to the following link.</p><p style=\"margin-left:40px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\" title=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\">https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83</a></p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager (SUM) を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a> (https://support.hpe.comで検索してダウンロード) を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong>重要な追加情報<em>：</em></strong></p><p><strong><em>(1.)</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>ファームウェアパッケージには最小バージョン (NVMイメージバージョン216.0.333011) が含まれていることに注意してください。</p></li><li><p>NVMイメージバージョン216.0.333011 (以降) にアップデートするには、Service Pack for ProLiant (SPP) に含まれる\"オンラインファームウェアアップグレードユーティリティ<em></em>\"を使用するか、手動で\"オンラインファームウェアアップグレードユーティリティ<em></em>\"をダウンロードしてインストールしてください。</p></li><li><strong>Service Pack for ProLiant (SPP) を使用して、NVMイメージバージョン216.0.333011 (以降) にアップデートします。</strong><ul style=\"list-style-type:circle\"><li>Service Pack for ProLiant (SPP) には\"オンラインファームウェアアップグレードユーティリティ<em></em>\"が含まれ、SPPはオフラインモードまたはオンラインモードで実行できます。ファームウェアアップデートを実行するには、SPPから起動してオフラインモードでアップデートするか、現在実行中のオペレーティングシステムからSPPを実行してオンラインモードでファームウェアをアップデートします。</li></ul></li></ul><p>または</p><ul><li><strong>オンラインファームウェアアップデートユーティリティを使用して、NVMイメージバージョン216.0.333011 (以降) に手動でアップデートします。</strong><ul style=\"list-style-type:circle\"><li>次のバージョンのいずれか (以降) の\"オンラインファームウェアアップグレードユーティリティ\"コンポーネントをダウンロードしてインストールします。<ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_c9c99d62694e4a6aa418b0a781&tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">Windows Server x64 Edition用HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティバージョン5.2.3.0 (またはそれ以降)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_2502ce87e3ba481081daea7a6c&tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティfor Linux x86_64バージョン1.9.3 (またはそれ以降)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_0d5f5f72693848838710781e5e&tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">VMware用HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティバージョン5.11.6 (またはそれ以降)</a></li></ul></li></ul></li></ul><p><strong>注記：</strong>\"オンラインファームウェアアップグレードユーティリティ<em></em>\"を使用してNVMイメージバージョン216.0.333011 (以降) にアップデートした後、新しいファームウェアを有効にするには再起動が必要です。ネットワークアダプターにNVMイメージバージョン216.0.333011 (以降) をインストールして実行したら、Platform Level Data Model (PLDM) のファームウェアアップデート方法 (\"ファームウェアパッケージ\"または\"fwpkg\"ファイル) を使用して最新のバージョンにアップデートできます。</p><p> </p><p><strong><em>(2.)</em></strong></p><ul style=\"list-style-type:square\"><li>このファームウェアパッケージに関しては、あまりの多くのバージョンを一度に飛び越えることによって発生する問題を避けるために、NVMイメージバージョン226.1.107.0ファームウェアにまずアップグレードすることをお勧めします。</li></ul><p style=\"margin-left:40px\">次のリンクを参照してください。</p><p style=\"margin-left:40px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\" title=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\">https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83</a></p><p> </p><p> </p>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong>IMPORTANT ADDITIONAL INFORMATION<em>:</em></strong></p><p><strong><em>(1.)</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Please be noted that firmware package has the minimum version (NVM Image version 216.0.333011).</p></li><li><p>To update to NVM Image version 216.0.333011 (or later), use the &quot;<em>Online Firmware Upgrade Utility</em>&quot; either from the Service Pack for ProLiant (SPP), or download and install the &quot;<em>Online Firmware Upgrade Utility</em>&quot; manually:</p></li><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Service Pack for ProLiant (SPP): </strong><ul style=\"list-style-type:circle\"><li>The Service Pack for ProLiant (SPP) contains the &quot;<em>Online Firmware Upgrade Utility</em>&quot; and the SPP can run in either offline mode or online mode. The firmware update can be performed either by booting from the SPP to update in offline mode or by running the SPP from the current running operating system and update the firmware in online mode.</li></ul></li></ul><p>OR</p><ul><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Online firmware update utility manually: </strong><ul style=\"list-style-type:circle\"><li>Download and install any of the following &quot;Online Firmware Upgrade Utility&quot; component versions (or later):<ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_c9c99d62694e4a6aa418b0a781&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions Version 5.2.3.0 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_2502ce87e3ba481081daea7a6c&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64 Version 1.9.3 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_0d5f5f72693848838710781e5e&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware Version 5.11.6 (or later)</a></li></ul></li></ul></li></ul><p><strong>Note:</strong> After updating to NVM Image version 216.0.333011 (or later) using the &quot;<em>Online Firmware Upgrade Utility</em>&quot;, a reboot is required to enable the new firmware. Once the network adapter has NVM Image version 216.0.333011 (or later) installed and running, the Platform Level Data Model (PLDM) firmware update method (&quot;firmware package&quot; or &quot;fwpkg&quot; file) can be used to update to the latest version.</p><p>&nbsp;</p><p><strong><em>(2.)</em></strong></p><ul style=\"list-style-type:square\"><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, to avoid issues caused by jumping too many versions at once.</li></ul><p style=\"margin-left:40px\">Please refer to the following link.</p><p style=\"margin-left:40px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\" title=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\">https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83</a></p><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eファームウェアパッケージfor BCM5741xアダプター"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2026-01-13T07:07:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164007"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164014"}],"SWKeys":[{"Name":"NIC_NXE_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"0fae485dae544088963e4af875a8a9c7"}]},{"ProductId":"7ff6f17e72894f4e8c910355a9fb9992","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 9.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 9.0上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプター用のドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.1.0</li><li>qedrntv version 3.71.62.0</li><li>qedentv version 3.71.73.0</li><li>qedi version 2.74.1.0</li></ul><p><strong>Known issue</strong>: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>"},{"Lang":"ja","Value":"<p>この製品には、以下のドライバーが含まれています。</p><ul><li>qedfバージョン2.74.1.0</li><li>qedrntvバージョン3.71.62.0</li><li>qedentvバージョン3.71.73.0</li><li>qediバージョン2.74.1.0</li></ul><p><strong>既知の問題</strong>: ドライバーのリセットを引き起こす操作を行うと、EnsNetWorldsのCPU使用率が高くなる可能性があります。次のドライバーリリースで完全なソリューションを提供することを目標とします</p>"},{"Lang":"cn","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.1.0</li><li>qedrntv version 3.71.62.0</li><li>qedentv version 3.71.73.0</li><li>qedi version 2.74.1.0</li></ul><p><strong>Known issue</strong>: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>"}],"Files":[{"Bytes":"5829683","DateModified":"2025-04-10T07:01:10","FileList":["/cp066737.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedi/QLC_bootbank_qedi_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.80.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.80.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedf/QLC_bootbank_qedf_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedi-1100237886221730174.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedentv--5062932650923935948.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedrntv--1300904974122159212.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedf--7068176324000061616.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"52b4936e6c906e0e6e15727394404f3b","Name":"cp066737.zip","Release":"2025-04-10T07:00:59","Revision":"","SHA1Sum":"77a502a20a040a8fc5fee78454b29b1ab09f5667","SHA256Sum":"d404056f1ddb5d1b7fef5f569b4fbc34b3e74404e1634cf240d7b64fb1b46d81","Size":"5MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"qedf","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.80.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.80.0-1OEM.800.1.0.20613240"},{"Name":"qedi","Version":"2.74.10.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバーfor VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002bd","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-809015900220","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021d","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021f","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-10T06:54:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports VMware vSphere ESXi&nbsp;9.0.</p><p>Known issue: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在VMware vSphere 9.0をサポートしています。</p><p>既知の問題: ドライバーのリセットを引き起こす操作を行うと、EnsNetWorldsのCPU使用率が高くなる可能性があります。次のドライバーリリースで完全なソリューションを提供することを目標とします</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports VMware vSphere ESXi&nbsp;9.0.</p><p>Known issue: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.00"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports VMware vSphere ESXi&nbsp;9.0.</p><p>Known issue: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在VMware vSphere 9.0をサポートしています。</p><p>既知の問題: ドライバーのリセットを引き起こす操作を行うと、EnsNetWorldsのCPU使用率が高くなる可能性があります。次のドライバーリリースで完全なソリューションを提供することを目標とします</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports VMware vSphere ESXi&nbsp;9.0.</p><p>Known issue: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.00"}],"SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.410.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedf:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.80.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.80.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedi:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"891f2ffc824a4cc49041d895d19d7c6d"}]},{"ProductId":"188764648e874fd98523f669c6e5a042","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作するHPE Intel icea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1724472","DateModified":"2025-11-16T10:47:15","FileList":["cp069534.xml","cpqsetup.exe","cp_data.xml","icea.cat","icea.inf","icea.sys","iceamsg.dll","install.xml","manifest_icea.man","nicdrvr.dll"],"MD5Sum":"a289e6d0e0cfdd08bcf9e656ca0d3c91","Name":"cp069534.exe","Release":"2025-11-16T10:32:38","Revision":"B","SHA1Sum":"27330c15008ec1bb5ea7c94ffa6e88c94423ef8c","SHA256Sum":"db8c612ad55a458b024b342de038b57e1302625ca93f24e72b133536b66884ec","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"TypeOfChange":"1","Version":"1.18.71.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icea Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"Intel iceaドライバーfor Microsoft Windows Server 2022"},{"Lang":"cn","Value":"Intel icea Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:50:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"cn"}],"Version":"1.18.71.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"cn"}],"Version":"1.18.71.0"}],"SWKeys":[{"Name":"icea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\icea.inf_amd64_0d313568beecbfb3"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"8baf70fa92224ee793e153bff16e6ca2"}]},{"ProductId":"4e5f478436f1475182a0e382836296e1","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H08","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H08_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000221","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on HPE ProLiant e910/e910t Server Blade running a supported Operating System in an HPE Edgeline EL8000 Converged Edge System."},{"Lang":"ja","Value":"このコンポーネントは、HPE Edgeline EL8000 コンバージドエッジシステムでサポートされているオペレーティングシステムを実行しているHPE ProLiant e910/e910tサーバーブレードに直接インストールできるアップデートされたシステムファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on HPE ProLiant e910/e910t Server Blade running a supported Operating System in an HPE Edgeline EL8000 Converged Edge System."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11277423","DateModified":"2026-01-14T19:40:53","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.62_2026_01_09-1.1/CP070228.xml","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.62_2026_01_09-1.1/H08_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070228.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070228.scexe"],"MD5Sum":"382938dce6626e8d21b243b63826394d","Name":"firmware-system-h08-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-15T01:30:22","Revision":"","SHA1Sum":"72fdb75ce90d999a602a2860ffaea0ecaa5315d4","SHA256Sum":"78f783763167002acd2b704974e7f5461b4fadf4d404ac9ff265ccc4f7e563d4","Size":"10MB","TargetGUIDs":["00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant e910/e910t Server Blade (H08)"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant e910/e910tサーバーブレード(H08)"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant e910/e910t Server Blade (H08)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:36:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"H08","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5c2b2d8b61d742ef9944ac94c5606fa6"}]},{"ProductId":"dd83343964ed4806840a86595ee2254d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3737488","DateModified":"2025-11-15T20:07:16","FileList":["cp068647.xml","cpqsetup.exe","KARM5ALSHPD8.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"dd57f4f560d0668de4ac7350d83a7242","Name":"cp068647.exe","Release":"2025-11-15T20:02:27","Revision":"D","SHA1Sum":"14b5d32bc1127aeb7f9659270d0b02083e073c43","SHA256Sum":"c8783d5e235cd847f1aa33655a68ce15b2f833ce6d1e476e32a2013e28a6d070","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO007680RWUFC","TargetGUID":"562340a5-304f-3730-3638-305257554643","Type":"sas"},{"Id":"VO003840RWUFF","TargetGUID":"562340a5-304f-3330-3834-305257554646","Type":"sas"},{"Id":"VO003840RWUFB","TargetGUID":"562340a5-304f-3330-3834-305257554642","Type":"sas"},{"Id":"VO001920RWUFE","TargetGUID":"562340a5-304f-3130-3932-305257554645","Type":"sas"},{"Id":"VO001920RWUFA","TargetGUID":"562340a5-304f-3130-3932-305257554641","Type":"sas"},{"Id":"VO000960RWUFD","TargetGUID":"562340a5-304f-3030-3936-305257554644","Type":"sas"},{"Id":"VO000960RWUEV","TargetGUID":"562340a5-304f-3030-3936-305257554556","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:17:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f2fede41d4c74f11919547b30cd6dbb7"}]},{"ProductId":"130da7feaa1d444b8b70a759892883b1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"This component installs a Registry change to fix a fatal Non-Maskable Interrupt (NMI) when ejecting an NVMe drive."},{"Lang":"ja","Value":"このコンポーネントは、NVMeドライブをイジェクトする際の致命的なマスク不可割り込み (NMI) を修正するためにレジストリの変更をインストールします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"638616","DateModified":"2025-11-18T06:11:14","FileList":["cp069728.xml","cpqsetup.exe","genericmsi.dll","nvmeejectfix5.msi","nvmefix5.cab"],"MD5Sum":"f9ca67e35b7f52693fd8b27a59cbcab9","Name":"cp069728.exe","Release":"2025-11-18T06:09:40","Revision":"J","SHA1Sum":"390680494d2f51d1adfc5e72c6a62bfe4be8fd5a","SHA256Sum":"f1c35168bc00ebf27ddabbefa4f22e33b341d31dcc103fac855e00844da3a66a","Size":"623KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82a707e7"],"TypeOfChange":"0","Version":"1.1.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVMe Drive Eject NMI Fix for Intel Xeon Processor Scalable Family for Microsoft Windows 64-bit"},{"Lang":"ja","Value":"Microsoft Windows 64ビット用NVMe Drive Eject NMI Fix forインテルXeonプロセッサースケーラブルファミリー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedDevices":[{"Dev":"2020","SubDev":"00EA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-2020159000ea","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T06:01:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.1.0.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.1.0.0"}],"SWKeys":[{"Name":"nvmeejectfix5.dll","SWKeyExpectedPath":"%ProgramFiles%\\nvmefix"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"20ae32eac4a1401299a8d17a3e777908"}]},{"ProductId":"ad60a281882240318ac9ec3091a5f1c9","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"ja","Value":"このコンポーネントには、HPE Storageアレイのためのファイバーチャネルホストバスアダプタードライバーサポートを提供する、QLogic Storportドライバーバージョン9.4.11.20が含まれています。"},{"Lang":"cn","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1731616","DateModified":"2026-01-05T06:32:21","FileList":["cp066322.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"MD5Sum":"d9de9e5c4457bc8f3160a716acd29fb9","Name":"cp066322.exe","Release":"2026-01-05T06:30:31","Revision":"b","SHA1Sum":"e8a5953a774d88a59999647b8e7df7cbddba41ce","SHA256Sum":"07b10f33908cd4fae68b9788b0eaa7282c29d08df66dea92f29428ce381297f3","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />［インストール］ボタンをクリックして、インストールを開始します。<br />"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 QLogic Storportドライバーfor Microsoft Windows Server 2019"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T14:55:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.11.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.11.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"}],"SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4ad7710b79bf431e8a3a583454a5db1c"}]},{"ProductId":"dac1034844fb4856950db71b5b2c959d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1249472","DateModified":"2025-11-16T13:40:20","FileList":["cp069524.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"488ce2d18ca8f47b098c004416ed9181","Name":"cp069524.exe","Release":"2025-11-16T13:25:35","Revision":"B","SHA1Sum":"943e4f16e51ca14d44945911cbee35a2195cc86c","SHA256Sum":"626b21e1d5ffe9fed35c0e9a65532dfe22fe175519ff708f6324b03e6ec66a48","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"TypeOfChange":"1","Version":"1.22.91.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40ea Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel i40eaドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel i40ea Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103C0000","Type":"pci","Ven":"8086"},{"Dev":"158A","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-158A15900000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T06:58:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"cn"}],"Version":"1.22.91.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"cn"}],"Version":"1.22.91.0"}],"SWKeys":[{"Name":"i40ea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5a97fd5cd0634cc6ba9d464ec85c11a5"}]},{"ProductId":"a407dd0c97da4a93aefdbd107b2f75e2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"3544876","DateModified":"2025-08-02T22:50:04","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-1.1/CP067393.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-1.1/TA15SEE0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067393.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067393.scexe"],"MD5Sum":"1d07add93897ea75c71f0af227e0f355","Name":"firmware-hdd-852266afdf_0HPD6-1.1_amd64.deb","Release":"2025-08-03T03:41:40","Revision":"","SHA1Sum":"9f7fd321c8dfb99db18ad9ae272903ca466d7c78","SHA256Sum":"44e84615f5e7fd297811375ad2ecd87caf14abced1a8810c7185bdb107f83e58","Size":"3MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"CP041561.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG002400JWJNN","TargetGUID":"452340a5-3047-3230-3430-304a574a4e4e","Type":"sas"},{"Id":"EG001800JWJNL","TargetGUID":"452340a5-3047-3130-3830-304a574a4e4c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:38:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"aa3fc98efae6465da04e3549f4ed3c53"}]},{"ProductId":"12aedd0e69a442908a699d2cefb38320","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"860430","DateModified":"2025-11-18T08:10:01","FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/elx-lpfc","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"MD5Sum":"c969d897d87252abb6be42acf31db609","Name":"kmod-elx-lpfc-14.4.731.6-1.rhel10u0.x86_64.rpm","Release":"2025-11-18T08:05:04","Revision":"","SHA1Sum":"7f4404efbb8082b62cad44e523fee8a8ebb287ce","SHA256Sum":"80bb16cade5e9ac828158358b588788029d35628518df4d1b049834f0a02a7f8","Size":"840KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.6"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.4.705.0-1.rhel10u0.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.4.705.0-1.rhel10u0.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.4.705.0-1.rhel10u0.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 10 Server Update 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 10 Server Update 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 10 Server Update 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-02T05:39:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.731.6"}],"SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"760a93fedc354daeb55a2fc0b59057c8"}]},{"ProductId":"84f4d8cbba034646b75e0fce6c455870","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains drivers for the Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントは、Broadcom NX1 1Gb Ethernetアダプターfor Microsoft Windows Server 2022およびWindows Server 2025を含みます。"},{"Lang":"cn","Value":"This component contains drivers for the Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2022 and Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"970336","DateModified":"2025-11-17T02:11:21","FileList":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp069002.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"0d406bb1b2d696fe5bbb48fdde1c321b","Name":"cp069002.exe","Release":"2025-11-17T01:56:04","Revision":"C","SHA1Sum":"91aaefb19b234f6848e2b4a609a6e636e8a92cf4","SHA256Sum":"2b0d0928513cb34aa34e602a6fe9132fe94c18b8744cdd5bed3d9ed77ee143ef","Size":"947KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"TypeOfChange":"1","Version":"221.0.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>Download the Smart Component to a directory on your hard drive and change to that directory.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the &quot;Install&quot; button to proceed with the installation.</li></ul>"},{"Lang":"ja","Value":"<ul><li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li><li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li><li>[インストール]ボタンをクリックして、インストールを開始します。</li></ul>"},{"Lang":"cn","Value":"<ul><li>Download the Smart Component to a directory on your hard drive and change to that directory.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the &quot;Install&quot; button to proceed with the installation.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"Lang":"ja","Value":"Broadcom NX1 1Gbドライバーfor Windows Server x64 Editions"},{"Lang":"cn","Value":"Broadcom NX1 1Gb Driver for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T03:19:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhances to update PNP ID table. (Plug and Play Identifier)</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、PNP IDテーブルのアップデートを強化します。(プラグアンドプレイ識別子)</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhances to update PNP ID table. (Plug and Play Identifier)</p>","Fixes":"","Lang":"cn"}],"Version":"221.0.8.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhances to update PNP ID table（Plug and Play Identifier）</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhances to update PNP ID table（Plug and Play Identifier）</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhances to update PNP ID table（Plug and Play Identifier）</p>","Fixes":"","Lang":"cn"}],"Version":"221.0.8.0"}],"SWKeys":[{"Name":"b57nd60a.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03030202","Model":"HPE Compute Scale-up Server 3250"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"65dc772cca1e40df9753ff841de74c49"}]},{"ProductId":"23c569ea92fb47f091a7a0c891acff72","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"22_46_3048-MCX623106AS-CDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30042","Version":"22.46.3048"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor Mellanox MCX623106AS-CDAT Ethernet 100Gb 2ポートQSFP56アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE&nbsp;(P25960-B21)</td><td>22.46.3048</td><td>MT_0000000437</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE&nbsp;(P25960-B21)</td><td>22.46.3048</td><td>MT_0000000437</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE&nbsp;(P25960-B21)</td><td>22.46.3048</td><td>MT_0000000437</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7849530","DateModified":"2025-10-08T13:13:19","FileList":["22_46_3048-MCX623106AS-CDA_Ax.pldm.signed","22_46_3048-MCX623106AS-CDA_Ax.pldm.xml","payload.json"],"MD5Sum":"73d412e48b6c59f68816bcf1ec00a17d","Name":"22_46_3048-MCX623106AS-CDA_Ax.pldm.fwpkg","Release":"2025-10-08T13:10:10","Revision":"","SHA1Sum":"e5a29f8bf519f58ac93317c4e74e57d7d5376f60","SHA256Sum":"16c22feb63de9c7e130a67cb336290d7620545a8fa6c04a2fe15f38cb9eb3793","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"TypeOfChange":"1","Version":"22.46.3048"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2ポートQSFP56アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-30T07:19:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new features and changes have been&nbsp;included in version 22.45.1020.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 22.45.1020:</strong></p><ul><li>PCC_CNP_COUNT could not be reset using the pcc_counter.sh script in the DOCA tools.</li><li>VQoS algorithm issue related to learning when an element is active and when it begins sending traffic.</li><li>A race condition that would prevent the application from transmitting when VQoS was enabled.</li><li>Bandwidth would drop when unbinding multiple VFs with VQoS enabled.</li><li>RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port&#39;s MAC.</li></ul>","Lang":"en"},{"Enhancements":"<p>セキュリティ強化の機能強化 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン26.45.1020には、新機能も変更も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン22.45.1020で修正されました：</strong></p><ul><li>DOCAツールのpcc_counter.shスクリプトを使用してPCC_CNP_COUNTをリセットできませんでした。</li><li>VQoSアルゴリズムに関する問題として、要素がアクティブ状態になるタイミング、およびトラフィックの送信を開始するタイミングを学習する際に生じます。</li><li>VQoSが有効な場合にアプリケーションの送信を妨げる競合状態。</li><li>VQoSが有効になっている複数のVFをバインド解除すると、帯域幅が低下します。</li><li>任意の宛先MACアドレスを持つRTTパケットが、有効な宛先MACを持つとして誤って処理されていました。新しいファームウェアでは、宛先MACがポートのMACと一致しない場合、RTTパケットが破棄されるようになりました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new features and changes have been&nbsp;included in version 22.45.1020.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 22.45.1020:</strong></p><ul><li>PCC_CNP_COUNT could not be reset using the pcc_counter.sh script in the DOCA tools.</li><li>VQoS algorithm issue related to learning when an element is active and when it begins sending traffic.</li><li>A race condition that would prevent the application from transmitting when VQoS was enabled.</li><li>Bandwidth would drop when unbinding multiple VFs with VQoS enabled.</li><li>RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port&#39;s MAC.</li></ul>","Lang":"cn"}],"Version":"22.45.1020"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;22.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;22.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;22.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;22.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;22.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;22.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"cn"}],"Version":"22.46.3048"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623106AS-CDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"f8d353a1a83e40f58ab4eb97c686fa11"}]},{"ProductId":"9c9f3096a89f4cc7b4a9b97b01822036","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4940376","DateModified":"2025-11-15T19:23:21","FileList":["cp068642.xml","cpqsetup.exe","HPG1PM897.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"befa5085935f3746472df380e25144d0","Name":"cp068642.exe","Release":"2025-11-15T19:17:52","Revision":"D","SHA1Sum":"f78287b419ce13242f6c7c1d3ffbdb3175f02d44","SHA256Sum":"399ddf887dba98f65b4cc790699fb38eed35be60bd01f34dab1064adb7a9684b","Size":"4MB","TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MK000480GZXRA","TargetGUID":"4d2340a5-304b-3030-3438-30475a585241","Type":"sata"},{"Id":"MK001920GZXRC","TargetGUID":"4d2340a5-304b-3130-3932-30475a585243","Type":"sata"},{"Id":"MK000960GZXRB","TargetGUID":"4d2340a5-304b-3030-3936-30475a585242","Type":"sata"},{"Id":"MK003840GZXRV","TargetGUID":"4d2340a5-304b-3330-3834-30475a585256","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:10:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8a0eab159b4b4e1bba5cf76f4366828e"}]},{"ProductId":"64242f6035c24947925dbb84f5af8b24","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.52 (01/09/2026)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.52 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17448592","DateModified":"2026-01-13T08:06:12","FileList":["cp070173.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U64_2.52_01_09_2026.signed.flash"],"MD5Sum":"d9f89390edd4c77b5ae86a77e1a02f0d","Name":"cp070173.exe","Release":"2026-01-13T08:03:11","Revision":"","SHA1Sum":"985b2b3a14695c3818950a2db88d87ff825d6a87","SHA256Sum":"2cc6d71feaae12baa73802366a51acfef59daf5eb56a5f1542d8a3825b3462b6","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.52_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant MicroServer Gen10 Plus v2 (U64) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T06:47:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.708（2.50_07_25_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"Implemented improvements to enhance user experience and optimize functionality.","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"Implemented improvements to enhance user experience and optimize functionality.","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"Implemented improvements to enhance user experience and optimize functionality.","Lang":"cn"}],"Version":"2.52_01-09-2026"}],"SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"7a4563ae09c54e42ac3664d46857fa00"}]},{"ProductId":"29b23e8f7b0d4dbf97ddc41ea0425103","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"WDC-ParisD-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"WDC_ParisD_WparisdASFD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5655","Version":"HPD1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB020000JXMVU"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB020000JXMVU"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB020000JXMVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>An error was found in the queue full handling process that results in the FUA bit not getting properly set, which could lead to the drive self-initiated reset.</p></li><li><p>The FW fix is to resolve the handling of FUA bit during the queue full handling process has been implemented.</p></li><li><p>The FW was confirmed to resolve the issue of drives resetting under queue full handling situations.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョン：<br />      </strong>HPD1<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />      なし<br /><br /><strong>前のファームウェアバージョン：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li><p>キューのフル処理プロセスでエラーが見つかりました。その結果、FUAビットが適切に設定されず、ドライブの自発的なリセットを発生させる可能性があります。</p></li><li><p>キューのフル処理プロセスの間にFUAビットの処理を解決するFWの修正が実装されました。</p></li><li><p>FWは、キューのフル処理状況でドライブがリセットされる問題を解決することが確認されました。</p></li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>An error was found in the queue full handling process that results in the FUA bit not getting properly set, which could lead to the drive self-initiated reset.</p></li><li><p>The FW fix is to resolve the handling of FUA bit during the queue full handling process has been implemented.</p></li><li><p>The FW was confirmed to resolve the issue of drives resetting under queue full handling situations.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6539691","DateModified":"2025-02-19T17:43:22","FileList":["payload.json","WDC_ParisD_WparisdASFD1.HPb","WDC_ParisD_WparisdASFD1.xml"],"MD5Sum":"85823c795fa7e708242381d4ee4c7644","Name":"WDC_ParisD_WparisdASFD1.fwpkg","Release":"2025-02-19T17:41:28","Revision":"B","SHA1Sum":"6d125c64f6010da733f3f0c516e9cbac9d7548f0","SHA256Sum":"1d06562bfb78ad03ea253724415b4cc9d536be3359e87fbf66ed567151f2c4ab","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5655"],"TypeOfChange":"1","Version":"HPD1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB020000JXMVU"},{"Lang":"ja","Value":"ドライブ用ユニバーサルファームウェアパッケージ - MB020000JXMVU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB020000JXMVU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB020000JXMVU","TargetGUID":"4d2340a5-3042-3032-3030-304a584d5655","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T20:33:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>An error was found in the queue fullhandling process that results in the FUA bit not getting properly set, which could lead to the drive self-initiated reset</li><li>The FW fix is to resolve the handling of FUA bit during the queue full handling process has been implemented</li><li>The FW was confirmed to resolve the issue of drives resetting under queue full handling situations.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>キューのフル処理プロセスでエラーが見つかりました。その結果、FUAビットが適切に設定されず、ドライブの自発的なリセットを発生させる可能性があります。</li><li>キューのフル処理プロセスの間にFUAビットの処理を解決するFWの修正が実装されました。</li><li>FWは、キューのフル処理状況でドライブがリセットされる問題を解決することが確認されました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>An error was found in the queue fullhandling process that results in the FUA bit not getting properly set, which could lead to the drive self-initiated reset</li><li>The FW fix is to resolve the handling of FUA bit during the queue full handling process has been implemented</li><li>The FW was confirmed to resolve the issue of drives resetting under queue full handling situations.</li></ul>","Lang":"cn"}],"Version":"HPD1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD1"}],"SWKeys":[{"Name":"MB020000JXMVU","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"12e10145ad2c40a5aeb104112fcffe11"}]},{"ProductId":"c3e42591dc7346b48d6b9ae18a9810a3","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U50_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34240472","DateModified":"2026-01-14T01:52:45","FileList":["cp070302.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U50_2.54_01_09_2026.signed.flash"],"MD5Sum":"c3c7f3a955c896886b6dcb0c8631949d","Name":"cp070302.exe","Release":"2026-01-14T01:50:22","Revision":"","SHA1Sum":"44e266ba8648ba7f5e05626c55bd9ee1293c2bd4","SHA256Sum":"f4c191935dc5082e988e7c54df886db9de078869edbce2ce581e73147c5aebec","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus（U50）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T07:54:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"3b42cc41859d47d4b6091d5d897c2657"}]},{"ProductId":"41c374eaf1f14df3b6eb451ccf1a1aaf","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、MB016000GWZHD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6018584","DateModified":"2025-09-17T11:21:11","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/CP068804.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/SHPEEVANSTG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068804.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068804.scexe"],"MD5Sum":"43d3f31fbc4c279d0764a07704ef43d8","Name":"firmware-hdd-7a1edae8e7-HPG1-8.1.x86_64.rpm","Release":"2025-09-17T16:12:04","Revision":"H","SHA1Sum":"17858aa2a8590fdb2faab13c5c487c65ba32cd83","SHA256Sum":"c1c1d7c0069241cdbc33ce9c8057fb30775d2539a718443aa87b960e994cc00a","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、およびMB016000GWZHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000GWZGT","TargetGUID":"4d2340a5-3042-3031-3030-3047575a4754","Type":"sata"},{"Id":"MB012000GWZGU","TargetGUID":"4d2340a5-3042-3231-3030-3047575a4755","Type":"sata"},{"Id":"MB014000GWZGV","TargetGUID":"4d2340a5-3042-3431-3030-3047575a4756","Type":"sata"},{"Id":"MB016000GWZHD","TargetGUID":"4d2340a5-3042-3631-3030-3047575a4844","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T03:52:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f8863e8510334a8fb6bd7e4316044cf8"}]},{"ProductId":"22f47c40d1bf4a1ab067b32f5bab759a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><ul><li>Added support for RHEL10.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><ul><li>Added support for RHEL10.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><ul><li>Added support for RHEL10.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3791164","DateModified":"2025-07-31T07:21:47","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-1.1/4ICRHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-1.1/CP067316.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067316.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067316.scexe"],"MD5Sum":"9ec15b70f946fa2266dd5775046a50f9","Name":"firmware-hdd-92d876cfea_4ICRHPK3-1.1_amd64.deb","Release":"2025-07-31T12:14:28","Revision":"","SHA1Sum":"62cf9f33dac6de381ce1414b6be575ae445a975a","SHA256Sum":"7b1562c10f466ef90399ccdaf89fe6e6c8ee129036ab71e93a82d87e54c8b07c","Size":"3MB","TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO002000KWVVC","TargetGUID":"562340a5-304f-3230-3030-304b57565643","Type":"nvme"},{"Id":"VO004000KWVUR","TargetGUID":"562340a5-304f-3430-3030-304b57565552","Type":"nvme"},{"Id":"MO001600KWVUU","TargetGUID":"4d2340a5-304f-3130-3630-304b57565555","Type":"nvme"},{"Id":"MO003200KWVUV","TargetGUID":"4d2340a5-304f-3330-3230-304b57565556","Type":"nvme"},{"Id":"MO006400KWVVA","TargetGUID":"4d2340a5-304f-3630-3430-304b57565641","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T09:33:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed issues described in Customer Bulletin&nbsp;at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111900en_us.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed issues described in Customer Bulletin&nbsp;at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111900en_us.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed issues described in Customer Bulletin&nbsp;at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111900en_us.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"}],"SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"50b939080efa43129643283ca6b4ab95"}]},{"ProductId":"eb650e36c9b84eb1b7c6c75d7ff3e9f2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000JWWQB and MB002000JWWQA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQBおよびMB002000JWWQA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000JWWQB and&nbsp;MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000JWWQB and&nbsp;MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4195976","DateModified":"2025-11-16T15:34:17","FileList":["cp068732.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNNSD8.rel","setup.dll"],"MD5Sum":"b44bbf6bca81d34ef53337415f3fb98e","Name":"cp068732.exe","Release":"2025-11-16T15:29:19","Revision":"E","SHA1Sum":"14a4746062f03892b84c4878b54e427eafb748f8","SHA256Sum":"bb6a32ec52e008529f825ef04711a2ab21eed48b735fbd7a6ad503c5314c7aef","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000JWWQBおよびMB002000JWWQAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000JWWQB","TargetGUID":"4d2340a5-3042-3430-3030-304a57575142","Type":"sas"},{"Id":"MB002000JWWQA","TargetGUID":"4d2340a5-3042-3230-3030-304a57575141","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T05:05:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5d391774ceff44a2a6b208614f9a29cc"}]},{"ProductId":"80ea6cb0c7d14159a1a37d37866e5b0c","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57412 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957412N4120HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41594","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957412N4120HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41594","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957412N4120HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Version":"235.1.164.14"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"1384927","DateModified":"2025-12-11T09:17:12","FileList":["BCM235.1.164.14_BCM957412N4120HC.HPb","BCM235.1.164.14_BCM957412N4120HC.xml","payload.json"],"MD5Sum":"1e470bf5e2e6bbeb5d4601533227b954","Name":"BCM235.1.164.14_BCM957412N4120HC.fwpkg","Release":"2025-12-11T09:13:35","Revision":"","SHA1Sum":"d32c1bf8d052fd11370927f35ce11fc7df320acc","SHA256Sum":"36c19a7411db17b2524dddce0663b553c4c81c195cf01a4339961a7f5b604dc1","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM57412 OCP3 adapter"},{"Lang":"ja","Value":"Broadcom Firmware Package for BCM57412 OCP3 adapter"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM57412 OCP3 adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-11T08:07:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"BCM_NXE_57412OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"086bfe6521324be8805b9a90ecb4f95c"}]},{"ProductId":"e90f7f429e824a139d97e1af559547fa","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H10","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H10_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on HPE Edgeline e920, e920d and e920t CTO Blade Server running a supported Operating System in an HPE Edgeline EL8000t Converged Edge System."},{"Lang":"ja","Value":"このコンポーネントは、HPE Edgeline EL8000tコンバージドエッジシステムでサポートされているオペレーティングシステムを実行しているHPE Edgeline e920t、e920dおよびe920t CTOブレードサーバーに直接インストールできるアップデートされたシステムファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on HPE Edgeline e920, e920d and e920t CTO Blade Server running a supported Operating System in an HPE Edgeline EL8000t Converged Edge System."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34236120","DateModified":"2026-01-14T06:43:18","FileList":["cp070255.xml","cpqsetup.exe","H10_2.54_01_09_2026.signed.flash","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"9a56bcfdd87356119ce3897853140664","Name":"cp070255.exe","Release":"2026-01-14T06:40:52","Revision":"","SHA1Sum":"4ff75444a112a4e57d68d7845363b0f386db341e","SHA256Sum":"83cf4d20c7edcd2ab93acf1b789622eac6be973927f6dd020971d80cef78dd2d","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023a"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Edgeline e920, e920d and e920t CTOブレードサーバー(H10)"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:50:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where megacell batteries might not manifest correctly.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where megacell batteries might not manifest correctly.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where megacell batteries might not manifest correctly.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_10-03-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"H10","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"FTP","Model":"FTP-Only System"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"ced6241773ff469f9cf5537770d81c7d"}]},{"ProductId":"3b175f364fc14c6da598ff868e4cfb48","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM2 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM2_1.20_F.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901502000000","Version":"1.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains PLDM firmware for UBM2 storage backplanes."},{"Lang":"ja","Value":"このファームウェアパッケージには、UBM2ストレージバックプレーンのPLDMファームウェアが含まれています。"},{"Lang":"cn","Value":"This firmware package contains PLDM firmware for UBM2 storage backplanes."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"64279","DateModified":"2024-09-13T05:13:18","FileList":["HPE_UBM2_1.20_F.HPb","HPE_UBM2_1.20_F.xml","payload.json"],"MD5Sum":"19ac58fab628d72a35cc265bec6cee58","Name":"HPE_UBM2_1.20_F.fwpkg","Release":"2024-09-13T05:09:10","Revision":"F","SHA1Sum":"db8184aeb99d025d5c3746b531b3c07c11dfc53a","SHA256Sum":"dd4a5f892598d44d89c68f4b3332cfbda9cdba8ce01771355529ace5ad9e4c5e","Size":"62KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901502000000"],"TypeOfChange":"1","Version":"1.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - UBM2 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 Servers"},{"Lang":"ja","Value":"ファームウェアパッケージ - UBM2バックプレーンPIC PLDMファームウェアfor Gen10/Gen10 Plus/Gen11サーバー"},{"Lang":"cn","Value":"Firmware Package - UBM2 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901502000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-13T04:32:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support both Gen10P and Gen11 servers</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Gen10PおよびGen11サーバーの両方をサポートします</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support both Gen10P and Gen11 servers</p>","Fixes":"","Lang":"cn"}],"Version":"1.20"},{"ReleaseNotes":[{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.20"}],"SWKeys":[{"Name":"UBM2PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U68","Model":"HPE ProLiant DL380 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant DL360 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"03cdf815345f4efd94751eaefd47e77f"}]},{"ProductId":"2e783bb79a1d489d9f42398711c931ef","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 10で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 10."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"106708","DateModified":"2025-09-15T15:35:53","FileList":["./etc/depmod.d/kmod-ixgbevf.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/ixgbevf/ixgbevf.ko","./usr/share/doc/kmod-ixgbevf","./usr/share/doc/kmod-ixgbevf/COPYING","./usr/share/doc/kmod-ixgbevf/README","./usr/share/doc/kmod-ixgbevf/pci.updates","./usr/share/man/man7/ixgbevf.7.gz","./usr/share/smartupdate/kmod-ixgbevf/component.xml"],"MD5Sum":"fd4cdb299f91612c1840f330c01ce201","Name":"kmod-ixgbevf-5.1.6-1.rhel10u0.x86_64.rpm","Release":"2025-09-15T15:31:29","Revision":"","SHA1Sum":"20758c5e55794974e177e7714998c6ea23aa3882","SHA256Sum":"c6d6b3c5b08da925930cff98d186d9922aee54b61c026822d66ee23bc8304bef","Size":"104KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2eb7029e"],"TypeOfChange":"1","Version":"5.1.6-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 10"},{"Lang":"ja","Value":"HPE Intel ixgbevfドライバーfor Red Hat Enterprise Linux 10"},{"Lang":"cn","Value":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"57ad","SubDev":"00FF","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad808600ff","Type":"pci","Ven":"8086"},{"Dev":"57B1","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57b180860003","Type":"pci","Ven":"8086"},{"Dev":"57AD","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad80860003","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-12T09:35:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Red Hat Enterprise Server 10をサポートするための初回リリースです。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"cn"}],"Version":"5.1.4-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"5.1.6-1"}],"SWKeys":[{"Name":"kmod-ixgbevf","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"08a9c17943ec4bf78d7a098efe80ef09"}]},{"ProductId":"bba1d0334a5f4b5fbc1a282af5290868","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB006000JYDNF, MB008000JYDPC and MB010000JYDNH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"}],"Files":[{"Bytes":"4656512","DateModified":"2025-11-16T14:53:13","FileList":["cp068735.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARBPESD5.rel","setup.dll"],"MD5Sum":"0e95648952e65b80537fcba7557c5b09","Name":"cp068735.exe","Release":"2025-11-16T14:47:21","Revision":"B","SHA1Sum":"4e72ebdee545c54609248f4195c30bc5cc93ef1d","SHA256Sum":"6e05dbc080161ac07ca9ab5d5346f520be2bde3a47b8da9a2a9bbd516c93f92a","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB006000JYDNF","TargetGUID":"4d2340a5-3042-3630-3030-304a59444e46","Type":"sas"},{"Id":"MB008000JYDPC","TargetGUID":"4d2340a5-3042-3830-3030-304a59445043","Type":"sas"},{"Id":"MB010000JYDNH","TargetGUID":"4d2340a5-3042-3031-3030-304a59444e48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T05:09:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ファームウェアの変更は、将来のFIPSコードリリースと1つのアサート修正のため調整されました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3fd1113df84b4bf58e44e3280cea8190"}]},{"ProductId":"8f93dddcb15744aab6bb426d5e84dee8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0.</li></ul>"}],"Files":[{"Bytes":"10045840","DateModified":"2025-09-21T20:18:56","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/CP068911.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/K511HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068911.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068911.scexe"],"MD5Sum":"c77dfadb3fb306242643f5b4b54dedce","Name":"firmware-hdd-befd42bd64-HPG3-6.1.x86_64.rpm","Release":"2025-09-22T01:08:16","Revision":"F","SHA1Sum":"521f5904c2488eb59cec95a9aa2372c677529fef","SHA256Sum":"ab5e8ea1f81b747ff4eefd86994abfdd876e1bda563a71bb3d99ecc04271f5fc","Size":"9MB","TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP043255.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK000480GZCNE","TargetGUID":"562340a5-304b-3030-3438-30475a434e45","Type":"sata"},{"Id":"VK000960GZCNF","TargetGUID":"562340a5-304b-3030-3936-30475a434e46","Type":"sata"},{"Id":"VK001920GZCNH","TargetGUID":"562340a5-304b-3130-3932-30475a434e48","Type":"sata"},{"Id":"VK003840GZCNK","TargetGUID":"562340a5-304b-3330-3834-30475a434e4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:51:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Improve the FW about data mismatch after SPL</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Improve the FW about data mismatch after SPL</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Improve the FW about data mismatch after SPL</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2a06adfbec30486d8f4a28dfefe3e391"}]},{"ProductId":"9a74de9c33bb4afeafe66492b230f37e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities."},{"Lang":"ja","Value":"iLO 5チャネルインターフェイスドライバーは、iLO 5管理コントローラーとの通信を行うことを可能にするソフトウェアです。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"585504","DateModified":"2025-11-18T03:29:17","FileList":["cp069724.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"MD5Sum":"8718418a8bc88a6dec6f564180d737ce","Name":"cp069724.exe","Release":"2025-11-18T03:26:48","Revision":"D","SHA1Sum":"41e290186c1c75152ea7bad3c8ab2389e33d098d","SHA256Sum":"6cb66d60b8b19fea7f1dd6b1395482b809e7914a9dd69797436fe2431d9d5a87","Size":"571KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.2.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"iLO 5チャネルインターフェイスドライバーfor Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T03:23:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.2.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.2.0"}],"SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\necheschif.inf_amd64_e49bd7dc444fc00f"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"54d504f6c59f4fa29b42a809d81d8fd5"}]},{"ProductId":"ff5a3639b5c744a8ac2e4611ce9482ea","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U32_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11929240","DateModified":"2026-01-14T03:37:58","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.62_2026_01_09-1.1/CP070225.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.62_2026_01_09-1.1/U32_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070225.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070225.scexe"],"MD5Sum":"d9e5eaf6fd42142ecc13933cc8e1881e","Name":"firmware-system-u32-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-14T09:27:58","Revision":"","SHA1Sum":"c1ab8e8c655e025dbd00d25919d755cae630ffc7","SHA256Sum":"010a049e579e049d74e5e25c8c741497622ad000cc9ef97f4ea7282cb216ad7e","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL360 Gen10 (U32)サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:32:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"32f8ab523245433c8a1063f6d1d5ccce"}]},{"ProductId":"f9dbbe8b7e1e4b98989ec92420b12775","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3902692","DateModified":"2025-08-02T21:55:05","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-1.1/CP067379.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-1.1/WBCPssssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067379.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067379.scexe"],"MD5Sum":"7122c23e814bb929904f191e6401c6c8","Name":"firmware-hdd-ef93133161_0HPD4-1.1_amd64.deb","Release":"2025-08-03T02:45:51","Revision":"","SHA1Sum":"4adb143c93c29abbf7bd4cb8708d2b4682c41486","SHA256Sum":"a86bca44f112149b974fd08c66a9d936bd5b25f3974095fc1945171989924efe","Size":"3MB","TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040353.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MO006400JWUGB","TargetGUID":"4d2340a5-304f-3630-3430-304a57554742","Type":"sas"},{"Id":"MO003200JWUGA","TargetGUID":"4d2340a5-304f-3330-3230-304a57554741","Type":"sas"},{"Id":"MO001600JWUFV","TargetGUID":"4d2340a5-304f-3130-3630-304a57554656","Type":"sas"},{"Id":"EO001600JWUGE","TargetGUID":"452340a5-304f-3130-3630-304a57554745","Type":"sas"},{"Id":"MO000800JWUFU","TargetGUID":"4d2340a5-304f-3030-3830-304a57554655","Type":"sas"},{"Id":"EO000800JWUGD","TargetGUID":"452340a5-304f-3030-3830-304a57554744","Type":"sas"},{"Id":"MO000400JWUFT","TargetGUID":"4d2340a5-304f-3030-3430-304a57554654","Type":"sas"},{"Id":"EO000400JWUGC","TargetGUID":"452340a5-304f-3030-3430-304a57554743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:09:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cc3ed153aac14ce49642988e0d6f2151"}]},{"ProductId":"3f4d9eceae63421389745abdf06f001a","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8002-MCX653436A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900348","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 PCIe4 x16 MCX653436A-HDAIアダプター: HPE部品番号P31348-B21およびP31348-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p style=\"margin-left:40px\"><strong>HDR / 200GbEケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR対NDRスイッチ相互運用ケーブル：</strong></p><ul><li>HDR    P45733-B21    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10mスプリッターアクティブ光ケーブル</li><li>HDR    P45733-B22    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30mスプリッターアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6277067","DateModified":"2025-10-08T13:07:19","FileList":["20_43_8002-MCX653436A-HDA_HPE_Ax.pldm.signed","20_43_8002-MCX653436A-HDA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"94304f7218fe1b0600708d374d0b4ed7","Name":"20_43_8002-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","Release":"2025-10-08T13:04:57","Revision":"","SHA1Sum":"2279460cdf84742fac6522ea0273c3405f3beb11","SHA256Sum":"d9e629b9829cca1daa28a73e3ed55d4621d058ca94b4b5f64fcaa2ec715271f8","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900348"],"TypeOfChange":"1","Version":"20.43.8002"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ（FWPKG）for HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 PCIe4 x16 OCP3 MCX653436A-HDAIアダプター: HPE部品番号P31348-B21およびP31348-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-08T12:23:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"20.43.8002"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653436A-HDAI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"5ad771f086b3497a8a7a8ebb9ccce819"}]},{"ProductId":"bc3fe657ed304b17aeeab14dfddb1656","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされるHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3610およびD3710BディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5145232","DateModified":"2025-12-11T16:11:15","FileList":["Config.xml","cp070009.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-6.00-build-000.bin","VDUFlash.dll"],"MD5Sum":"b9243bf90fe1be6fdf06728ff9f89bee","Name":"cp070009.exe","Release":"2025-12-11T16:09:35","Revision":"I","SHA1Sum":"159f52e67c128b5f9b97b756533e7a01a4849aae","SHA256Sum":"cd641c6ae6dd93df5200d18513638fe4c22bd581250421c958d0afccce8e10d0","Size":"4MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/tD3600B /tD3700B /tD3610B /tD3710B /v6.00 /iReveille-Release-6.00-build-000.bin /lD3000B.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"ja","Value":"HPE D3610B/D3710B 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"},{"Lang":"cn","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2"},"SupportedDevices":[{"Id":"D3610B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3710B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-09T10:23:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"6.00"}],"SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"37e2560b0c9446af84c14aebea5d053b"}]},{"ProductId":"31f49e59526b43cb994f293d4205e9e6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000GZYVT、MB014000GZYVU、MB016000GZYVV、MB018000GYCLL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19843305","DateModified":"2025-03-07T11:21:56","FileList":["/CP065980_BUILD_2.data","/CP065980.vmexe64","/CP065980.vmfile","/CP065980_VMw.zip","/CP065980.xml","/payload.json","/CP065980_VMw.zip/index.xml","/CP065980_VMw.zip/vendor-index.xml","/CP065980_VMw.zip/metadata.zip","/CP065980_VMw.zip/vib20/CP065980/HPE_bootbank_CP065980_HPG4.2-1OEM.800.1.0.20613240.vib","/CP065980_VMw.zip/metadata.zip/vendor-index.xml","/CP065980_VMw.zip/metadata.zip/vmware.xml","/CP065980_VMw.zip/metadata.zip/vibs/CP065980-7630158784340027244.xml","/CP065980_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065980_HPG4.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"f53963d7ff3eefaa7078cc019c8336bc","Name":"CP065980.zip","Release":"2025-03-07T11:21:06","Revision":"C","SHA1Sum":"38c930877b64866a43cc258d1ae8868e9e3b1f78","SHA256Sum":"65b2ebfbdf6e0b5fca353a807178805ec3e3f8a0c2c5d7564778f666c54e0911","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP065980","Version":"HPG4.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042459.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVVおよびMB018000GYCLL ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB012000GZYVT","TargetGUID":"4d2340a5-3042-3231-3030-30475a595654","Type":"sata"},{"Id":"MB014000GZYVU","TargetGUID":"4d2340a5-3042-3431-3030-30475a595655","Type":"sata"},{"Id":"MB016000GZYVV","TargetGUID":"4d2340a5-3042-3631-3030-30475a595656","Type":"sata"},{"Id":"MB018000GYCLL","TargetGUID":"4d2340a5-3042-3831-3030-304759434c4c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:16:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"feef26afe3244381aacf3ac21b08abbc"}]},{"ProductId":"01cbc1be755b4243b92be8c9339313eb","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."},{"Lang":"ja","Value":"セキュアブートモードでのHPE Mellanox MFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"77204","DateModified":"2025-10-07T14:48:09","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/mst_pci.ko","./lib/modules/6.4.0-150600.21-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"MD5Sum":"580d73b91181f80af0c6ce9052234404","Name":"kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-10-07T14:42:04","Revision":"","SHA1Sum":"1f5d5f2dafd6842a08497e92c9013d7da8e26802","SHA256Sum":"a84ff083e5140378d38b038c1a2360adde605070519d2db6c48c1f99e9cb01d8","Size":"75KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.33.0-169"},{"Bytes":"31340772","DateModified":"2025-10-07T14:53:33","FileList":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/09","./usr/lib/.build-id/09/f109281b8e907068ffd7c1c342858dff784e01","./usr/lib/.build-id/0f","./usr/lib/.build-id/0f/06c107262adada878deb0f9fa83d774f751f48","./usr/lib/.build-id/10","./usr/lib/.build-id/10/0a8c0576f6803c90885f113b58394a44f0a871","./usr/lib/.build-id/10/c7a8c5696bd094204a596bce50b1ba1fb846cb","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/1db7f49eaa674db0f2554468466f00011e0172","./usr/lib/.build-id/2d","./usr/lib/.build-id/2d/758b0ad35a7f5767e77fd249b875d632a45733","./usr/lib/.build-id/39","./usr/lib/.build-id/39/8a0d4dd55e47ce4f6d070acecfdb122289d33f","./usr/lib/.build-id/42","./usr/lib/.build-id/42/aaea6007932f09a5c3309dbc5a5ccc072cf035","./usr/lib/.build-id/48","./usr/lib/.build-id/48/dedbe624bd18afdad53e7f49e678733023b908","./usr/lib/.build-id/4c","./usr/lib/.build-id/4c/35559fa839acc99a9c75a3dc8422b24cf1bda7","./usr/lib/.build-id/51","./usr/lib/.build-id/51/39ebac45d29b13d9165f1f74cda6ff3da41cde","./usr/lib/.build-id/5d","./usr/lib/.build-id/5d/bbdf0b0c073e7be1d04a3e0e647fddddf686e2","./usr/lib/.build-id/60","./usr/lib/.build-id/60/bfe2319a1267622d58682d4f739da72567e8f8","./usr/lib/.build-id/63","./usr/lib/.build-id/63/0048b7ed76eec96328ace78f9397670dfbf39d","./usr/lib/.build-id/64","./usr/lib/.build-id/64/70e23454c94c00d458d330decb11f4bfada781","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/9765d63e6ec7eff0b34d9355ed62c54238c03a","./usr/lib/.build-id/74","./usr/lib/.build-id/74/2fa7fe1af4bc2e5546226ffb413385abe30056","./usr/lib/.build-id/76","./usr/lib/.build-id/76/cddc0af7cf963769c8ae730fd3443ff95fe869","./usr/lib/.build-id/81","./usr/lib/.build-id/81/0aff60310d4da78fcf604ce98bf4d0bb82983b","./usr/lib/.build-id/82","./usr/lib/.build-id/82/c932a3195593bd1f6ff6c462cc7aebe3c64add","./usr/lib/.build-id/85","./usr/lib/.build-id/85/e0ca034196c107f7a88b23cd7af942d9eb2d40","./usr/lib/.build-id/8b","./usr/lib/.build-id/8b/36d15bed3b078dd01aae8ed23fef0552ebdcc3","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/0f00edeff5dd8f8daf3f6d054cac5b30775ada","./usr/lib/.build-id/91","./usr/lib/.build-id/91/34aa2fbe03361af16f037094235b54e2957851","./usr/lib/.build-id/93","./usr/lib/.build-id/93/e20b792c9e9e6b18557e3b4d5741b0f54e8044","./usr/lib/.build-id/ac","./usr/lib/.build-id/ac/30394f6339d378871506935512a61504b6c304","./usr/lib/.build-id/b4","./usr/lib/.build-id/b4/51faf1296981ec859e8d515c8ff9644bfc64ec","./usr/lib/.build-id/b5","./usr/lib/.build-id/b5/0e1c1d7671fc03dcc87f74b4d41893efcadf54","./usr/lib/.build-id/b7","./usr/lib/.build-id/b7/82443d6962db647257a8fb8879cf28fbad0c93","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/3bdd4b85f6928930b1030cba40cee60458d945","./usr/lib/.build-id/bf/5eec04e20f7ffc87fc5b4375658c981df3ac11","./usr/lib/.build-id/c1","./usr/lib/.build-id/c1/326615a196bad2ef9cf7906a82fb301ac3ffd1","./usr/lib/.build-id/c3","./usr/lib/.build-id/c3/af518fbf4f31021d87d31824acaeaf981a4d86","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/d7af687801a418c6cafd69c3d986659039589d","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/840cae88a2719081ace2774afbe4a39a9ff08d","./usr/lib/.build-id/f1","./usr/lib/.build-id/f1/81098d4fef21db82f53346f2045097b4ec8b34","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/cbdaeee8cd3ad8284fdd44f0af6317f466e9de","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/876e7ad783090ff0db05fe68e6ffdbec0348c0","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/ext_libs/libcrypto.so.3","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/gpu_drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/device_info","./usr/share/mft/device_info/json","./usr/share/mft/device_info/json/0x11.json","./usr/share/mft/device_info/json/0x19.json","./usr/share/mft/device_info/json/0x1e.json","./usr/share/mft/device_info/json/0x1f5.json","./usr/share/mft/device_info/json/0x1f7.json","./usr/share/mft/device_info/json/0x1ff.json","./usr/share/mft/device_info/json/0x209.json","./usr/share/mft/device_info/json/0x20b.json","./usr/share/mft/device_info/json/0x20d.json","./usr/share/mft/device_info/json/0x20f.json","./usr/share/mft/device_info/json/0x211.json","./usr/share/mft/device_info/json/0x212.json","./usr/share/mft/device_info/json/0x214.json","./usr/share/mft/device_info/json/0x216.json","./usr/share/mft/device_info/json/0x218.json","./usr/share/mft/device_info/json/0x21c.json","./usr/share/mft/device_info/json/0x21e.json","./usr/share/mft/device_info/json/0x220.json","./usr/share/mft/device_info/json/0x222.json","./usr/share/mft/device_info/json/0x224.json","./usr/share/mft/device_info/json/0x226.json","./usr/share/mft/device_info/json/0x247.json","./usr/share/mft/device_info/json/0x249.json","./usr/share/mft/device_info/json/0x24b.json","./usr/share/mft/device_info/json/0x24d.json","./usr/share/mft/device_info/json/0x24e.json","./usr/share/mft/device_info/json/0x250.json","./usr/share/mft/device_info/json/0x252.json","./usr/share/mft/device_info/json/0x253.json","./usr/share/mft/device_info/json/0x254.json","./usr/share/mft/device_info/json/0x256.json","./usr/share/mft/device_info/json/0x257.json","./usr/share/mft/device_info/json/0x259.json","./usr/share/mft/device_info/json/0x25b.json","./usr/share/mft/device_info/json/0x270.json","./usr/share/mft/device_info/json/0x274.json","./usr/share/mft/device_info/json/0x278.json","./usr/share/mft/device_info/json/0x27c.json","./usr/share/mft/device_info/json/0x282.json","./usr/share/mft/device_info/json/0x288.json","./usr/share/mft/device_info/json/0x2900.json","./usr/share/mft/device_info/json/0x3.json","./usr/share/mft/device_info/json/0x3000.json","./usr/share/mft/device_info/json/0x3480.json","./usr/share/mft/device_info/json/0x6b.json","./usr/share/mft/device_info/json/0x6e.json","./usr/share/mft/device_info/json/0x6f.json","./usr/share/mft/device_info/json/0x70.json","./usr/share/mft/device_info/json/0x71.json","./usr/share/mft/device_info/json/0x72.json","./usr/share/mft/device_info/json/0x73.json","./usr/share/mft/device_info/json/0x7e.json","./usr/share/mft/device_info/json/0x7f.json","./usr/share/mft/device_info/json/0x80.json","./usr/share/mft/device_info/json/0x82.json","./usr/share/mft/device_info/json/0x84.json","./usr/share/mft/device_info/json/0xd.json","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/gpu","./usr/share/mft/prm_dbs/gpu/ext","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers","./usr/share/mft/prm_dbs/retimers/ext","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"MD5Sum":"ca1d4515777e3755640b9716487e189a","Name":"mft-4.33.0-169.sles15sp6.x86_64.rpm","Release":"2025-10-07T14:42:04","Revision":"","SHA1Sum":"5e56c1c10340bc0c0c0cebcc99f5fbf9dbcf77b7","SHA256Sum":"1d6a65a8df11b29c03dac184e37d9fb0ff6ac74d2efa9883c715c510fcd62314","Size":"29MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.33.0-169"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.</p><p>To install or upgrade the driver:<br /><br />If using 6.4.0-150600.21-default kernel or any future errata:</p><p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm&nbsp;mft-4.33.0-169.sles15sp6.x86_64.rpm</strong></p><p>Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.</p><p>To install or upgrade the driver:<br /><br />If using 6.4.0-150600.21-default kernel or any future errata:</p><p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm&nbsp;mft-4.33.0-169.sles15sp6.x86_64.rpm</strong></p><p>Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.</p><p>To install or upgrade the driver:<br /><br />If using 6.4.0-150600.21-default kernel or any future errata:</p><p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm&nbsp;mft-4.33.0-169.sles15sp6.x86_64.rpm</strong></p><p>Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP6 (AMD64/EM64T)"},{"Lang":"ja","Value":"SUSE Linux Enterprise Server 15 SP6 (AMD64/EM64T)のセキュアブートモードでのMellanoxアダプターのファームウェアアップデート用のHPE Mellanox MFT前提条件RPM"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP6 (AMD64/EM64T)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-07T12:13:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.32.0-120"},{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.33.0-169"}],"SWKeys":[{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"8f21239f09bb4c239012f26be8a87dca"}]},{"ProductId":"f1a885eabd844ec18e0dab540c21f1c8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4105896","DateModified":"2025-11-17T09:38:15","FileList":["cp068651.xml","cpqsetup.exe","KAPM6ALFHPD4.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"31c1423e79d2ca264a79c5a3d716cf2c","Name":"cp068651.exe","Release":"2025-11-17T09:33:30","Revision":"B","SHA1Sum":"00f8df909caf978c384b83369e378268dc55b972","SHA256Sum":"5176dbc041c20cd64475c4a2fbfcd8985b798dc59c6193a67b36d9580c81f5eb","Size":"3MB","TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO003840XZCLT","TargetGUID":"562340a5-304f-3330-3834-30585a434c54","Type":"sas"},{"Id":"MO001600XZCLV","TargetGUID":"4d2340a5-304f-3130-3630-30585a434c56","Type":"sas"},{"Id":"MO000800XZCLQ","TargetGUID":"4d2340a5-304f-3030-3830-30585a434c51","Type":"sas"},{"Id":"VO007680XZCMB","TargetGUID":"562340a5-304f-3730-3638-30585a434d42","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:40:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブヘルスのクエリが誤ったドライブ予測エラーを引き起こす可能性がある、まれなケースに対処するための修正を追加しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"34f98f1102e24c1dbf193b48205c52da"}]},{"ProductId":"d33174a587ab4b3ea4d5e4e22de786d1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000GWKGR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6408688","DateModified":"2025-09-17T12:42:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/CP068845.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/HVLAeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068845.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068845.scexe"],"MD5Sum":"3705af6f54a27acc11f7ec973072f23d","Name":"firmware-hdd-7f2a26e6d0-HPG1-14.1.x86_64.rpm","Release":"2025-09-17T17:32:04","Revision":"N","SHA1Sum":"6603c62464b7b5467e8ec59b8fd0e93d5ef6ad24","SHA256Sum":"2719683b7cbf8aa0df9dcb001985401f909e21bcd5c1b8ef56801ff55b4a2fb4","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP041521.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWKGR Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWKGRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000GWKGR","TargetGUID":"4d2340a5-3042-3630-3030-3047574b4752","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T18:35:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RHEL 10のサポートを追加しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10.</p>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9b7922ea3a25464699d43072eb87f8c0"}]},{"ProductId":"0e95d953f6c341e2ab45544cad6adaa1","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U33_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11556496","DateModified":"2026-01-14T06:31:59","FileList":["cp070238.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U33_3.62_01_09_2026.signed.flash"],"MD5Sum":"8deb927bf3ff81d1f71abb37684dc6bc","Name":"cp070238.exe","Release":"2026-01-14T06:28:56","Revision":"","SHA1Sum":"9b493319e1d67644840ab6e36ad7343666666bb3","SHA256Sum":"0332415a004d42757a3fe699d0a3a3afc23ae7b3a4492aa36b13d87dc87ad4dc","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;</p><p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> </p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;</p><p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen10 (U33) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML110 Gen10 (U33)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen10 (U33) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:57:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"66da2d27d8d644f69b1dc1b73c1095f9"}]},{"ProductId":"a2bc84f793fd4972b6196baf3df85eb6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWUDB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"20843316","DateModified":"2025-03-07T06:43:56","FileList":["/CP065992_BUILD_5.data","/CP065992.vmexe64","/CP065992.vmfile","/CP065992_VMw.zip","/CP065992.xml","/payload.json","/CP065992_VMw.zip/index.xml","/CP065992_VMw.zip/vendor-index.xml","/CP065992_VMw.zip/metadata.zip","/CP065992_VMw.zip/vib20/CP065992/HPE_bootbank_CP065992_HPD4.5-1OEM.800.1.0.20613240.vib","/CP065992_VMw.zip/metadata.zip/vendor-index.xml","/CP065992_VMw.zip/metadata.zip/vmware.xml","/CP065992_VMw.zip/metadata.zip/vibs/CP065992--2795774151834853535.xml","/CP065992_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065992_HPD4.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"22414565850210583866b2e24fe498d7","Name":"CP065992.zip","Release":"2025-03-07T06:43:07","Revision":"C","SHA1Sum":"9efd0a2fc4417b63d05f15cb5b3ec28d059f692e","SHA256Sum":"efdd3a0073a07f436068a83b1afff60cc13bfcbc7db0b2620cdac321d3839964","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065992","Version":"HPD4.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041510.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JWUDB ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000JWUDB","TargetGUID":"4d2340a5-3042-3431-3030-304a57554442","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:09:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5268232d10d445a596b065d77b66da67"}]},{"ProductId":"02754226ca24415fbdc877dfe47af242","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.00"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.00"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.00"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.00"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.00"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.00"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"この x64 Smartコンポーネントは、次のストレージコントローラー用のファームウェアを提供します。 HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10 コントローラー"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"9689783","DateModified":"2025-12-04T00:37:22","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.00-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.00-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.00-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.00-1.1/CP069171.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.00-1.1/HPE_luxor_8.00.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.00-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.00-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.00-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.00-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069171.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069171.scexe"],"MD5Sum":"b44b23c1a154fb0fc54bea31626e0073","Name":"firmware-smartarray-f7c07bdbbd-8.00-1.1.x86_64.rpm","Release":"2026-02-02T00:00:00","Revision":"","SHA1Sum":"a7e1ff8c9ab4bd79a8a3e5cfd865bf5db08a378f","SHA256Sum":"fc583a666e3221ae22e4f4dd8110a89de204837f79212036190c63829cb9856d","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.00"}],"Installation":{"Command":"CP069171.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp; rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp; rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp; rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux(x64) - HPE SmartアレイP408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10コントローラー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2026-03-03T07:57:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"cn"}],"Version":"8.00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"cn"}],"Version":"8.00"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b35660d96a244bb39b5585a5b5af5811"}]},{"ProductId":"7726a9100f9d46aeb7672151b0d319ea","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1537FFFF0000","Version":"1.2877"},{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-153700000000","Version":"1.2877"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline System running a supported Microsoft Windows Operating System installed in HPE Edgeline EL8000/EL8000t chassis."},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Edgeline EL8000/EL8000tシャーシに設置されたサポート対象のMicrosoft Windowsオペレーティングシステムを実行するHPE Edgelineシステムに直接インストールできるNICファームウェアを提供します。"},{"Lang":"cn","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline System running a supported Microsoft Windows Operating System installed in HPE Edgeline EL8000/EL8000t chassis."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9869256","DateModified":"2026-01-21T20:26:19","FileList":["BootIMG.FLB","BOOTUTILW64E.EXE","cp070449.xml","cpqsetup.exe","ilorest_chif.dll","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","payload.json"],"MD5Sum":"36da5cc42278805dfd369b7b2c6a02bd","Name":"cp070449.exe","Release":"2026-01-21T20:09:37","Revision":"B","SHA1Sum":"dd9cd0a89f9bcc6df24cd96d8e2fa9236c2823f8","SHA256Sum":"a4448111eb0b78d1efdc2ab6a42c427d02ab396966502ec4b95cd3855fdfe3bb","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-1537FFFF0000","a6b1a447-382a-5a4f-8086-153700000000"],"TypeOfChange":"1","Version":"1.2877"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed from HPSUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをインストールするには、以下の手順に従ってください：</strong></p><p> </p><p>CP0xxxxx.exeをダブルクリックします。</p><p>または </p><p>スタートメニューからコマンドプロンプトを開きます<br />コマンドプロンプトで、CP0xxxxx.exeがコピーされているパスに移動します<br />exeファイルの実行例を以下に示します：<br />    <br />    >> CP0xxxxx.exe</p><p> </p><p><strong>Service Pack for EdgelineからSmart Update Managerを使用してファームウェアをインストールするには、次の手順に従います：</strong></p><p> </p><p>このSmartコンポーネントは、Service Pack for Edgeline（SPE）でも利用可能であり、HPSUMからインストールできます</p><p> </p><p>インストール手順についてはSUMユーザーガイドを、詳細についてはSPEリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed from HPSUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Edgeline i210 NIC Firmware Component for Microsoft Windows"},{"Lang":"ja","Value":"HPE Edgeline i210 NICファームウェアコンポーネントfor Microsoft Windows"},{"Lang":"cn","Value":"HPE Edgeline i210 NIC Firmware Component for Microsoft Windows"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"9000"},"SupportedDevices":[{"Dev":"1537","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153700000000","Type":"pci","Ven":"8086"},{"Dev":"1537","SubDev":"0000","SubVen":"FFFF","TargetGUID":"a6b1a447-382a-5a4f-8086-1537FFFF0000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-21T15:33:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"1.2877"},{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"1.2877"}],"SWKeys":[{"Name":"i210_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1208eb584aec4cea897af4d3a34651f1"}]},{"ProductId":"73ec3bde4c824e4abd7a12e09eb4bcb4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6235700","DateModified":"2025-09-21T21:54:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/CP068926.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/SSKYBT512ND9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068926.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068926.scexe"],"MD5Sum":"6580557b2226ef22f6dfa36939df6ecf","Name":"firmware-hdd-bdfb8e99d9-HPD9-2.1.x86_64.rpm","Release":"2025-09-22T02:43:41","Revision":"B","SHA1Sum":"0a6fa7ab81b025a3681bc05cac8ff5c3b3fe7c40","SHA256Sum":"2d218a9cbcc865581237ece8c2821acdffa82be92b319e7bb29618ebf9dbefce","Size":"5MB","TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP041693.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG001200JWJNQ","TargetGUID":"452340a5-3047-3130-3230-304a574a4e51","Type":"sas"},{"Id":"EG000600JWJNP","TargetGUID":"452340a5-3047-3030-3630-304a574a4e50","Type":"sas"},{"Id":"EG001200MXJQU","TargetGUID":"452340a5-3047-3130-3230-304d584a5155","Type":"sas"},{"Id":"EG000600JXLVV","TargetGUID":"452340a5-3047-3030-3630-304a584c5656","Type":"sas"},{"Id":"EG001200JXLWA","TargetGUID":"452340a5-3047-3130-3230-304a584c5741","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:08:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>定期的なFWメンテナンスリリース。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>定期的なFWメンテナンスリリース。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"241ac77ec9144d9c9a5d27ff919c2fbe"}]},{"ProductId":"e5d8389759aa4832a8475a2ff763f16b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp; &nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Reommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp; &nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Reommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3444144","DateModified":"2025-11-17T11:49:20","FileList":["cp068639.xml","cpqsetup.exe","GPM1643ASAD5.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"d78c5f7be71d1d1dcaf9d33062b13071","Name":"cp068639.exe","Release":"2025-11-17T11:44:00","Revision":"D","SHA1Sum":"886df1f2d9de7e06392c89fd6a95399413544354","SHA256Sum":"3963f7e2f3c2ea44dce9e2071c5d6d057a92bfc7e222bdf0bc4e61a3e5ddfdb4","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO015360JWZJN","TargetGUID":"562340a5-304f-3531-3336-304a575a4a4e","Type":"sas"},{"Id":"VO007680JWZJL","TargetGUID":"562340a5-304f-3730-3638-304a575a4a4c","Type":"sas"},{"Id":"VO003840JWZJK","TargetGUID":"562340a5-304f-3330-3834-304a575a4a4b","Type":"sas"},{"Id":"VO001920JWZJH","TargetGUID":"562340a5-304f-3130-3932-304a575a4a48","Type":"sas"},{"Id":"VO000960JWZJF","TargetGUID":"562340a5-304f-3030-3936-304a575a4a46","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:04:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"23d8ca08b6234a54bf8d8752132880fd"}]},{"ProductId":"27053985f2354572a6633cc6a63bb7ef","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX6314 10/25GbE 2p SFP28 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_46_3048-MCX631432AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30007","Version":"26.46.3048"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージ - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE&nbsp; (P42041-B21)</td><td>26.46.3048</td><td>MT_0000000551</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE&nbsp; (P42041-B21)</td><td>26.46.3048</td><td>MT_0000000551</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE&nbsp; (P42041-B21)</td><td>26.46.3048</td><td>MT_0000000551</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7275892","DateModified":"2025-10-09T08:01:17","FileList":["26_46_3048-MCX631432AS-ADA_Ax.pldm.signed","26_46_3048-MCX631432AS-ADA_Ax.pldm.xml","payload.json"],"MD5Sum":"bfcbf292dd566a74073a7d5cb03080e5","Name":"26_46_3048-MCX631432AS-ADA_Ax.pldm.fwpkg","Release":"2025-10-09T07:59:02","Revision":"","SHA1Sum":"cca04645733e8db8ff376ac65c792c465db05ce8","SHA256Sum":"68de66219360c6388e411d06d75607efef3f149db12a8d956a404b2055b288a6","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f15b30007"],"TypeOfChange":"1","Version":"26.46.3048"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3.  iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ(FWPKG)- Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-30T09:26:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>No new features and changes have been included in version 26.45.1020.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 26.45.1020:</strong></p><ul><li>Configuring PHY_RATE_MASK for 10G in NV settings incorrectly disabled 10G capabilities.</li><li>RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port&#39;s MAC.</li></ul>","Lang":"en"},{"Enhancements":"<p>セキュリティ強化の機能強化 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。<br /> </p><p><strong>バージョン26.45.1020には、新機能も変更も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン26.45.1020で修正されました：</strong></p><ul><li>NV設定で10GのPHY_RATE_MASKを構成すると、10G機能が誤って無効になります。</li><li>任意の宛先MACアドレスを持つRTTパケットが、有効な宛先MACを持つとして誤って処理されていました。新しいファームウェアでは、宛先MACがポートのMACと一致しない場合、RTTパケットが破棄されるようになりました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>No new features and changes have been included in version 26.45.1020.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 26.45.1020:</strong></p><ul><li>Configuring PHY_RATE_MASK for 10G in NV settings incorrectly disabled 10G capabilities.</li><li>RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port&#39;s MAC.</li></ul>","Lang":"cn"}],"Version":"26.45.1020"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;26.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;26.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;26.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"cn"}],"Version":"26.46.3048"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX631432AS-ADAI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"fd3fc6991e0a4d6995242fafbf93508c"}]},{"ProductId":"2a95310f5de64c9fad6c33cfacf5d307","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK&nbsp; Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK&nbsp; Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0</li></ul>"}],"Files":[{"Bytes":"8192464","DateModified":"2025-11-14T09:43:19","FileList":["cp068634.xml","cpqsetup.exe","K511HPG3.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"2369bf4141e5d60c87b9466902f4de20","Name":"cp068634.exe","Release":"2025-11-14T09:38:00","Revision":"D","SHA1Sum":"9518cba68a31f21b2a866d9f26f50625e4f992ad","SHA256Sum":"185b50ee0d312409eeca9994b2412f5f669f7bed8032ecc2a937d9b54c60b51a","Size":"7MB","TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl　\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK000480GZCNE","TargetGUID":"562340a5-304b-3030-3438-30475a434e45","Type":"sata"},{"Id":"VK000960GZCNF","TargetGUID":"562340a5-304b-3030-3936-30475a434e46","Type":"sata"},{"Id":"VK001920GZCNH","TargetGUID":"562340a5-304b-3130-3932-30475a434e48","Type":"sata"},{"Id":"VK003840GZCNK","TargetGUID":"562340a5-304b-3330-3834-30475a434e4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T08:46:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3695033488784f1a95f15765cebc6677"}]},{"ProductId":"24bbe0adc4dc4c7385b6f5ad6aecf867","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL issued.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL issued.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"9521727","DateModified":"2025-09-21T20:10:29","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/CP068908.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/K503HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068908.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068908.scexe"],"MD5Sum":"c8505fbcd127c26b0664206e83528834","Name":"firmware-hdd-8e1e8083c5-HPG3-6.1.x86_64.rpm","Release":"2025-09-22T00:59:28","Revision":"F","SHA1Sum":"5f2baa8ff9e52995caf21da4c0ed2c12485dffd4","SHA256Sum":"0a2bb6f2f4d83fccda450c12230402e3e4a4f53613c885bd10075a0ac293b970","Size":"9MB","TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP043280.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MK003840GWXFL","TargetGUID":"4d2340a5-304b-3330-3834-30475758464c","Type":"sata"},{"Id":"MK001920GWXFK","TargetGUID":"4d2340a5-304b-3130-3932-30475758464b","Type":"sata"},{"Id":"MK000960GWXFH","TargetGUID":"4d2340a5-304b-3030-3936-304757584648","Type":"sata"},{"Id":"MK000480GWXFF","TargetGUID":"4d2340a5-304b-3030-3438-304757584646","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:47:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Improve the FW about data mismatch after SPL issued</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Improve the FW about data mismatch after SPL issued</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Improve the FW about data mismatch after SPL issued</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"426ba3dc2e0c4272b5336f0e1357a237"}]},{"ProductId":"c91a34b258694c1696514c7b51041b33","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A48_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33594205","DateModified":"2026-01-13T06:35:10","FileList":["A48_4.00_01_09_2026.signed.flash","A48_4.00_01_09_2026.xml","payload.json"],"MD5Sum":"f3f1c60321b995a9c04225199c254656","Name":"A48_4.00_01_09_2026.fwpkg","Release":"2026-01-13T06:31:56","Revision":"","SHA1Sum":"69bdde62e0adfab326dd26a3a8ab5a8dfaf9ad4a","SHA256Sum":"413baae9aa996f2ebf9624bbc6813459a164779a025e7ccfb3e867518bb8f843","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus(A48) サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T06:31:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.90_10-03-2025"},{"ReleaseNotes":[{"Enhancements":"Implemented improvements to enhance user experience and optimize functionality.","Fixes":"","Lang":"en"},{"Enhancements":"Implemented improvements to enhance user experience and optimize functionality.","Fixes":"","Lang":"ja"},{"Enhancements":"Implemented improvements to enhance user experience and optimize functionality.","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"9273b95b3b6f437db74e2698ecd875dd"}]},{"ProductId":"d152e4f9638d4a6a962a3424ad625ef5","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A41_3.70_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.70 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17940509","DateModified":"2026-01-14T02:04:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.70_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.70_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.70_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.70_2026_01_09-1.1/A41_3.70_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.70_2026_01_09-1.1/CP070202.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.70_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.70_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.70_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.70_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070202.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070202.scexe"],"MD5Sum":"71cd852ce8a0aecb9c924f06918762a7","Name":"firmware-system-a41-3.70_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-14T07:54:17","Revision":"","SHA1Sum":"018688fba89bdf42b459e82da36c71b974bfd645","SHA256Sum":"29f11c6fc12eeb82fb8e2da6febff9b95783577b76eacdae6c57cb67905fa348","Size":"17MB","TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"1","Version":"3.70_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプすることにより、hpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL325 Gen10 (A41) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL325 Gen10 (A41)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL325 Gen10 (A41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T10:29:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>CVE-2025-3052を軽減するために、デフォルトのセキュアブートDBXをアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。システムROMのこのリビジョンには、AMD第1世代EPYCプロセッサー用のAMDリファレンスコードNaplesPI 1.0.0.Rが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Redfish経由でのBIOS設定の変更が、同じ起動中にBIOSアップデートが実行された場合に、失敗するという問題に対処しました。</p><p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_09-05-2025"},{"ReleaseNotes":[{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.70_01-09-2026"}],"SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bb06bda69ad1445a94c9714ca5164380"}]},{"ProductId":"fade5b11c713406a8e9c5f691c073fe5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 9.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 9.0上で動作するHPE Intel ixgbenアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.22.1.0</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;1.22.1.0</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.22.1.0</p>"}],"Files":[{"Bytes":"215035","DateModified":"2025-09-22T04:06:22","FileList":["/cp068939.xml","/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.zip","/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.zip/index.xml","/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.zip/vib20/ixgben/INT_bootbank_ixgben_1.22.1.0-1OEM.900.0.24755229.vib","/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/ixgben--2436509561728493357.xml","/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-ixgben_1.22.1.0-1OEM.900.0.24755229.xml"],"MD5Sum":"fb30b39a79ae4872e65241c30a0a1209","Name":"cp068939.zip","Release":"2025-09-22T04:06:13","Revision":"","SHA1Sum":"9cb3d0b11c4875820dee034392e6968957e25e3f","SHA256Sum":"da70a74072eac0910f4774d8ebdf07564d597220b88011444ab84487330891a5","Size":"209KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"ixgben","Version":"1.22.1.0-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用する場合：</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixgben Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE Intel ixgbenドライバーfor VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE Intel ixgben Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"57ad","SubDev":"00FF","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad808600ff","Type":"pci","Ven":"8086"},{"Dev":"57B1","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57b180860003","Type":"pci","Ven":"8086"},{"Dev":"57AD","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad80860003","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T01:54:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now adds support for E610 device.</p>","Fixes":"<ul><li>Known issue: Firmware OROM version displays as &quot;0.0.0&quot; via &quot;ethtool -i&quot;.</li><li>Known issue: Firmware OROM version displays incorrectly via &quot;esxcli network nic get -n interface&quot;.</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品では、E610デバイスのサポートが追加されました。</p>","Fixes":"<ul><li>既知の問題: 「ethtool -i」を実行すると、ファームウェア OROM バージョンが「0.0.0」と表示されます。</li><li>既知の問題: 「esxcli network nic get -n interface」でファームウェアOROMバージョンが正しく表示されません。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now adds support for E610 device.</p>","Fixes":"<ul><li>Known issue: Firmware OROM version displays as &quot;0.0.0&quot; via &quot;ethtool -i&quot;.</li><li>Known issue: Firmware OROM version displays incorrectly via &quot;esxcli network nic get -n interface&quot;.</li></ul>","Lang":"cn"}],"Version":"2025.07.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"Intel-ixgben:1.22.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.22.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"f8ead878e3794e388b8989f0b30478c9"}]},{"ProductId":"066920f0b4684f1da260602d0174d2e0","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021d","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021d","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809015900220","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021d","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f015900220","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002bd","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8090159002bd","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f0159002bd","Version":"8.65.23"}]},"MinimumActiveVersion":"8.55.12","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、HPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするためのユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1825863","DateModified":"2024-12-11T01:47:18","FileList":["payload.json","ql_hp_ah_mbi_8.65.23_pldm.HPb","ql_hp_ah_mbi_8.65.23_pldm.xml"],"MD5Sum":"7b58c1098e4fe0020a2190e12f35881d","Name":"ql_hp_ah_mbi_8.65.23_pldm.fwpkg","Release":"2024-12-11T01:44:56","Revision":"","SHA1Sum":"c9fb2fe8893f7c2dc142ce76de467c2985e94020","SHA256Sum":"9d2d27c83a71f1423f599d05de4bcabc223bbd514f24a73249419d98b67a6a1d","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-80801590021f","a6b1a447-382a-5a4f-1077-80841590021f","a6b1a447-382a-5a4f-1077-80901590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-80801590021b","a6b1a447-382a-5a4f-1077-80841590021b","a6b1a447-382a-5a4f-1077-80901590021b","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80801590021a","a6b1a447-382a-5a4f-1077-80841590021a","a6b1a447-382a-5a4f-1077-80901590021a","a6b1a447-382a-5a4f-1077-80f01590021d","a6b1a447-382a-5a4f-1077-80f01590021f","a6b1a447-382a-5a4f-1077-80f015900220","a6b1a447-382a-5a4f-1077-80f01590021b","a6b1a447-382a-5a4f-1077-80f01590021a","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-80f0159002bd"],"TypeOfChange":"1","Version":"8.65.23"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p><p>&nbsp;</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e</a></p><p>&nbsp;</p><p>&nbsp;</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>このファームウェアパッケージには最小バージョン（コンボイメージv8.55.12）が必要であることに注意してください。最初にファームウェアをアップデートするには、次のリンクを参照してください。</p><p> </p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e</a></p><p> </p><p> </p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p><p>&nbsp;</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e</a></p><p>&nbsp;</p><p>&nbsp;</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Firmware Package for Arrowhead adapters"},{"Lang":"ja","Value":"Arrowheadアダプター用HPE QLogic FastLinQファームウェアパッケージ"},{"Lang":"cn","Value":"HPE QLogic FastLinQ Firmware Package for Arrowhead adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-12-04T04:03:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"8.65.14"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.65.23"}],"SWKeys":[{"Name":"NIC_FLQ_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"4b658756c8a14d80ba2c6e5ea4f3a675"}]},{"ProductId":"8d0bd1ce26004a9e8191551757cba42d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5551065","DateModified":"2025-09-17T12:56:13","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/CP068853.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/WBCQssssASFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068853.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068853.scexe"],"MD5Sum":"2e39fbfeffb91542bfae497ecbe31a67","Name":"firmware-hdd-24384980ec-HPD2-4.1.x86_64.rpm","Release":"2025-09-17T17:47:05","Revision":"D","SHA1Sum":"c2ab12e5d3e976a0bcde54c2daeda418364bef8e","SHA256Sum":"0806423c340cc0b844c0d93e0e6ea3edc8eaef1b634f056ce0a3c4953f0b4ea8","Size":"5MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP040307.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MO000800JXBEV","TargetGUID":"4d2340a5-304f-3030-3830-304a58424556","Type":"sas"},{"Id":"MO001600JXBFP","TargetGUID":"4d2340a5-304f-3130-3630-304a58424650","Type":"sas"},{"Id":"MO003200JXBFQ","TargetGUID":"4d2340a5-304f-3330-3230-304a58424651","Type":"sas"},{"Id":"MO006400JXBFR","TargetGUID":"4d2340a5-304f-3630-3430-304a58424652","Type":"sas"},{"Id":"MO000960JXBFA","TargetGUID":"4d2340a5-304f-3030-3936-304a58424641","Type":"sas"},{"Id":"MO001920JXBFT","TargetGUID":"4d2340a5-304f-3130-3932-304a58424654","Type":"sas"},{"Id":"MO003840JXBFU","TargetGUID":"4d2340a5-304f-3330-3834-304a58424655","Type":"sas"},{"Id":"MO007680JXBGA","TargetGUID":"4d2340a5-304f-3730-3638-304a58424741","Type":"sas"},{"Id":"MO015360JXBFV","TargetGUID":"4d2340a5-304f-3531-3336-304a58424656","Type":"sas"},{"Id":"EO000400JXBEU","TargetGUID":"452340a5-304f-3030-3430-304a58424555","Type":"sas"},{"Id":"EO000800JXBFL","TargetGUID":"452340a5-304f-3030-3830-304a5842464c","Type":"sas"},{"Id":"EO001600JXBFN","TargetGUID":"452340a5-304f-3130-3630-304a5842464e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:39:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"87a0067ffcf54b28965bb0d0634585e6"}]},{"ProductId":"6559625804344daab70667e2f1b0b044","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQBおよびMB002000JWWQAドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000JWWQB and&nbsp;MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000JWWQB and&nbsp;MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6077750","DateModified":"2025-09-17T11:18:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/CP068802.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/SCIMARRNNSD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068802.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068802.scexe"],"MD5Sum":"84003513ceb620d9894736d11305a3d4","Name":"firmware-hdd-adb3ab8147-HPD8-8.1.x86_64.rpm","Release":"2025-09-17T16:08:20","Revision":"H","SHA1Sum":"97904324297ff32a46c3311911ef5f51adf557bf","SHA256Sum":"91b70be08d4dac255c32e08898eeba6d33258cbabeda56b92ab2f624d139478d","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP043262.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000JWWQBおよびMB002000JWWQAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JWWQB","TargetGUID":"4d2340a5-3042-3430-3030-304a57575142","Type":"sas"},{"Id":"MB002000JWWQA","TargetGUID":"4d2340a5-3042-3230-3030-304a57575141","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T03:50:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e3c7f7487e78456cbb96dab8196735b3"}]},{"ProductId":"170e9646d84b43c984c43d017aedc665","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.62 (01/09/2026)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33613551","DateModified":"2026-01-14T03:33:16","FileList":["payload.json","U34_3.62_01_09_2026.signed.flash","U34_3.62_01_09_2026.xml"],"MD5Sum":"d6cffa1c811e74e98caa7959caa5bb5e","Name":"U34_3.62_01_09_2026.fwpkg","Release":"2026-01-14T03:30:03","Revision":"","SHA1Sum":"5b4d3e7d975b9bcaa8b196cb0f4273f47c0eb00d","SHA256Sum":"eecfc29c99ba6b9f44c1cb7f303267e9408831bd41951c4d262b7a01302e5b4c","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:45:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"279f7b3717a44a58bf58d64fb5727df1"}]},{"ProductId":"1655bc494b334729864d929c38544849","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Online Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"Lang":"cn","Value":"升级HPE ProLiant Gen9扩展卡上机柜固件的在线智能组件"},{"Lang":"ja","Value":"HPE ProLiant Gen9エキスパンダーのエンクロージャーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17517688","DateModified":"2025-03-07T05:59:42","FileList":["/CP064922_BUILD_20.data","/CP064922.vmexe","/CP064922.vmexe64","/CP064922.vmfile","/CP064922_VMw.zip","/CP064922.xml","/payload.json","/CP064922_VMw.zip/index.xml","/CP064922_VMw.zip/vendor-index.xml","/CP064922_VMw.zip/metadata.zip","/CP064922_VMw.zip/vib20/CP064922/HPE_bootbank_CP064922_5.15.20-8.0.0.20613240.vib","/CP064922_VMw.zip/metadata.zip/vendor-index.xml","/CP064922_VMw.zip/metadata.zip/vmware.xml","/CP064922_VMw.zip/metadata.zip/vibs/CP064922--7112293561139101723.xml","/CP064922_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064922_5.15.20-8.0.0.20613240.xml"],"MD5Sum":"0ec86241b6c1ac70ae5c67b7c7eee662","Name":"CP064922.zip","Release":"2025-03-07T05:50:04","Revision":"C","SHA1Sum":"e2c6d693c1f940f6dc44d14ac062f7f5cb991f77","SHA256Sum":"829adadc87df0dd31251fca436d3cc4a1fc8cd3363659b20fc497dd80d3dc83b","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15","VibList":[{"Name":"CP064922","Version":"5.15.20-8.0.0.20613240"}]}],"Installation":{"Command":"CP064922.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp; &nbsp; &nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><br /><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp; &nbsp; &nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><br /><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp; &nbsp; &nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><br /><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE 12 Gb/s SASエキスパンダーファームウェアfor HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"12000"},"SupportedDevices":[{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-06T03:56:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support&nbsp;HPE ProLiant DL180 Gen10 Server</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>HPE ProLiant DL180 Gen10サーバーをサポート</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support&nbsp;HPE ProLiant DL180 Gen10 Server</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.15"},{"ReleaseNotes":[{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"cn"}],"Version":"5.15"}],"SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1491d75394fa433089f3444461292a8c"}]},{"ProductId":"c165fa12d9644f82b813c7e585ce9181","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp068008.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2453509","DateModified":"2025-11-26T03:39:53","FileList":["./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1/CP069830.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1/cp068008.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1/cp068008.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069830.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069830.scexe"],"MD5Sum":"3d48e238d5ec2cd29d5623f131f7772c","Name":"firmware-dl20gen10plus_me-06.00.03.708-2.1.x86_64.rpm","Release":"2025-11-26T09:33:05","Revision":"B","SHA1Sum":"9053911d11deed236e93d127e50a4665a5176b24","SHA256Sum":"4d47ea06fbffff441140d42051ab55352a1ce0a3c48bdbc1dc778b3828d991a8","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20 Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-26T09:29:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"36f9ee2997194fb68b7825318c47f4d0"}]},{"ProductId":"4502e15e8e6c48d58b299fb45b3d1658","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.52 (01/09/2026)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.52 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16811691","DateModified":"2026-01-13T08:13:44","FileList":["payload.json","U64_2.52_01_09_2026.signed.flash","U64_2.52_01_09_2026.xml"],"MD5Sum":"13f1011d85708f87af395c0b82759e91","Name":"U64_2.52_01_09_2026.fwpkg","Release":"2026-01-13T08:11:16","Revision":"","SHA1Sum":"66c2c92eb8f8c7fed73656a6557bbe0d7a7feb17","SHA256Sum":"217b3210def2f14dc065dfd9d634cfdc0557e7001d82366a41110c91b2a3d581","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.52_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant MicroServer Gen10 Plus v2 (U64)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T06:49:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.708（2.50_07_25_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_01-09-2026"}],"SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"91809834cfec44b5a2f36639a03638c5"}]},{"ProductId":"118ba074c4b3495fbd26210e14a17511","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U40_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33609701","DateModified":"2026-01-13T03:42:54","FileList":["payload.json","U40_3.62_01_09_2026.signed.flash","U40_3.62_01_09_2026.xml"],"MD5Sum":"95d79fe357bbbd10aa4197ac59e7b265","Name":"U40_3.62_01_09_2026.fwpkg","Release":"2026-01-13T03:40:19","Revision":"","SHA1Sum":"728a691c1fd7317765be43251699a8e8299e0c77","SHA256Sum":"10f51c943aff7c227aa2487fd33bb1f43cfdcaf825ca560bd504bdbcafd75fa7","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers "},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers "},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:39:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"b07a7b6a2ce443c1bde9a23a5d440e4c"}]},{"ProductId":"386eb9df6414454ca63bfe17b21ac760","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"20215793","DateModified":"2025-03-06T07:51:08","FileList":["/CP066008_BUILD_3.data","/CP066008.vmexe64","/CP066008.vmfile","/CP066008_VMw.zip","/CP066008.xml","/payload.json","/CP066008_VMw.zip/index.xml","/CP066008_VMw.zip/vendor-index.xml","/CP066008_VMw.zip/metadata.zip","/CP066008_VMw.zip/vib20/CP066008/HPE_bootbank_CP066008_HPD8.3-1OEM.800.1.0.20613240.vib","/CP066008_VMw.zip/metadata.zip/vendor-index.xml","/CP066008_VMw.zip/metadata.zip/vmware.xml","/CP066008_VMw.zip/metadata.zip/vibs/CP066008--9042039589112603064.xml","/CP066008_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066008_HPD8.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"c75acfac143bf8e1dbb25f50a153b4c5","Name":"CP066008.zip","Release":"2025-03-06T07:50:18","Revision":"C","SHA1Sum":"7194fd4985fc536914a14d387ba6a2de90628d51","SHA256Sum":"5cb69e0d9449837a9192dbb2e9654e9b0a6591b0cafcbf71ec8509c83b585664","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP066008","Version":"HPD8.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043259.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB006000JWWQN","TargetGUID":"4d2340a5-3042-3630-3030-304a5757514e","Type":"sas"},{"Id":"MB008000JWWQP","TargetGUID":"4d2340a5-3042-3830-3030-304a57575150","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:07:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"14ca93ffa5f94a888d3e2e649aaea7a8"}]},{"ProductId":"a94c7d3500c34676be3fda4cef325374","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - &nbsp;EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - &nbsp;EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4398828","DateModified":"2025-08-03T01:48:56","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-1.1/CP067344.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-1.1/SKESTEDD.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067344.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067344.scexe"],"MD5Sum":"eed89cc4980d9570bc8b862e51884152","Name":"firmware-hdd-a05f29cef3_0HPDD-1.1_amd64.deb","Release":"2025-08-03T06:39:05","Revision":"","SHA1Sum":"1f1b2a8852b721f557bb97c137fcb10720532b51","SHA256Sum":"d4ef0fed2a5ef8d0f9cfe028e005cc02ad807a37849cbce3def9fbfbfcf2d384","Size":"4MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"Installation":{"Command":"CP040712.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000600JWCPF","TargetGUID":"452340a5-3048-3030-3630-304a57435046","Type":"sas"},{"Id":"EH000900JWCPH","TargetGUID":"452340a5-3048-3030-3930-304a57435048","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:32:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"cn"}],"Version":"HPDD"}],"SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6fa9d5eea20747d6b6f8cd01dfded45d"}]},{"ProductId":"05f0508175404d989c50e4f9a4e09a23","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"DirectoryScan":false,"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":" This component provides updated IE firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":" This component provides updated IE firmware that can be installed directly on supported Operating Systems. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"6478386","DateModified":"2025-08-21T21:19:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/CP068486.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051154.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051154.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051155.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051155.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068486.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068486.scexe"],"MD5Sum":"13a4b550ad3c46453c330355aba00e99","Name":"firmware-iegen10-0.2.3.0-8.1.x86_64.rpm","Release":"2025-08-22T02:10:05","Revision":"H","SHA1Sum":"12580bac8941a23f70f709b3471a42f1fbb6953d","SHA256Sum":"84554e850710f76c18ba689b4bbafc67cc1d0c20a5b45a3b731095a1f5c9a84e","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><br />To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><p>&nbsp;</p><ul></ul>"},{"Lang":"ja","Value":"<p><br />ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p><p> </p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバー "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-09-22T02:05:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(F) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>Ver. 0.2.3.0(F)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver. 0.2.3.0と同等です。ファームウェアをバージョン0.2.3.0にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョンFにアップグレードする必要はありません。</p><p>このLinuxコンポーネントは、Service Pack for ProLiant 2024.11.00.00 と互換性があります。</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。一部のシステムでは、これによりCPU使用率が一時的に低下したり、ネットワークトラフィックの持続が1秒未満になったりする可能性があります。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(F) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(H) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision H if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(H) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision H if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(H) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision H if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"}],"SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:sd:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e91049f03c4649bd991453920d081df9"}]},{"ProductId":"83f19a40734047f1a91d25f9cd465999","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.35.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.35.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.35.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.35.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under VMware VMware vSphere 8.0 and VMware vSphere 9.0."},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 8.0およびVMware vSphere 9.0で動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under VMware VMware vSphere 8.0 and VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"16766461","DateModified":"2025-10-02T23:51:03","FileList":["/CP069006_BUILD_1.data","/CP069006.vmexe64","/CP069006.vmfile","/CP069006_VMw.zip","/CP069006.xml","/payload.json","/CP069006_VMw.zip/index.xml","/CP069006_VMw.zip/vendor-index.xml","/CP069006_VMw.zip/metadata.zip","/CP069006_VMw.zip/vib20/CP069006/HPE_bootbank_CP069006_1.43.0.1-8.0.0.20613240.vib","/CP069006_VMw.zip/metadata.zip/vendor-index.xml","/CP069006_VMw.zip/metadata.zip/vmware.xml","/CP069006_VMw.zip/metadata.zip/vibs/CP069006-7332251503998627248.xml","/CP069006_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069006_1.43.0.1-8.0.0.20613240.xml"],"MD5Sum":"db77032c055ef0a89f02b09f7b322167","Name":"CP069006.zip","Release":"2025-10-02T23:50:21","Revision":"","SHA1Sum":"c14e4d73d6f4ceedef2c78079ffc937fabd64789","SHA256Sum":"a83b1a4328294721d2810f2dbdf07d2bf903139594b6fe927b8da7b840d419b7","Size":"15MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"1.43.0","VibList":[{"Name":"CP069006","Version":"1.43.0.1-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NX1 Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"Broadcom NX1オンラインファームウェアアップグレードユーティリティfor VMware"},{"Lang":"cn","Value":"Broadcom NX1 Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T05:36:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"1.42.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"1.43.0"}],"SWKeys":[{"Name":"BCM_OPEN","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U47","Model":"HPE ProLiant DX220n Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DX380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DX325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DX360 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"77e1e25b563e457bbff2e0dfa78c3b36"}]},{"ProductId":"02e2779ea258441c8ba6426a8772f536","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"850271","DateModified":"2025-11-18T07:10:57","FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/elx-lpfc","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"MD5Sum":"b699c6f281e30fa9a36bdf90c3391559","Name":"kmod-elx-lpfc-14.4.731.6-1.rhel9u7.x86_64.rpm","Release":"2025-11-18T07:06:04","Revision":"","SHA1Sum":"646de25f40dcc6339c80dd4ce472b8b88058dbd1","SHA256Sum":"e4425b96768eb32e5f4d3cffa1a3d54f44d283aa212f49059e775a9442847ce4","Size":"830KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.6"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.520.3-1.rhel9u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.520.3-1.rhel9u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.520.3-1.rhel9u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 9 Server Update 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 Server Update 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 9 Server Update 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-26T05:08:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10.0</p><p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"},{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 9.7</p><p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 9.7</p><p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 9.7</p><p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.731.6"}],"SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"db2ccf4425484f7fb600b9bd17c535c7"}]},{"ProductId":"58f3059c65eb403984076353b9f058af","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-30525852514b","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-305258525248","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-30525852524b","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30525852514c","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30525852524c","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30525852524e","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305259455744","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model: MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MO000960RXRQK、MO001920RXRRH、MO003840RXRRK、VO000960RXRQL、VO001920RXRRL、VO003840RXRRN、およびVO007680RYEWD"},{"Lang":"cn","Value":"This package provides firmware for the following drive model: MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2140748","DateModified":"2025-02-19T17:31:16","FileList":["payload.json","Seagate_Cooper_SCOOPRHPESD4.HPb","Seagate_Cooper_SCOOPRHPESD4.xml"],"MD5Sum":"5ff1a86b03cb98848d7a4184c30acfb8","Name":"Seagate_Cooper_SCOOPRHPESD4.fwpkg","Release":"2025-02-19T17:29:17","Revision":"B","SHA1Sum":"c8c2de7eb0c933f9dbc8b7b1e3cc6431417575bb","SHA256Sum":"a3bb0d6882d2d7257baebff8739de96a46b3a33f2e59ab5c03bbaa36456ec006","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3936-30525852514b","4d2340a5-304f-3130-3932-305258525248","4d2340a5-304f-3330-3834-30525852524b","562340a5-304f-3030-3936-30525852514c","562340a5-304f-3130-3932-30525852524c","562340a5-304f-3330-3834-30525852524e","562340a5-304f-3730-3638-305259455744"],"TypeOfChange":"2","Version":"HPD4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO000960RXRQK、MO001920RXRRH、MO003840RXRRK、VO000960RXRQL、VO001920RXRRL、VO003840RXRRN、VO007680RYEWD"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO000960RXRQK","TargetGUID":"4d2340a5-304f-3030-3936-30525852514b","Type":"sas"},{"Id":"MO001920RXRRH","TargetGUID":"4d2340a5-304f-3130-3932-305258525248","Type":"sas"},{"Id":"MO003840RXRRK","TargetGUID":"4d2340a5-304f-3330-3834-30525852524b","Type":"sas"},{"Id":"VO000960RXRQL","TargetGUID":"562340a5-304f-3030-3936-30525852514c","Type":"sas"},{"Id":"VO001920RXRRL","TargetGUID":"562340a5-304f-3130-3932-30525852524c","Type":"sas"},{"Id":"VO003840RXRRN","TargetGUID":"562340a5-304f-3330-3834-30525852524e","Type":"sas"},{"Id":"VO007680RYEWD","TargetGUID":"562340a5-304f-3730-3638-305259455744","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T18:48:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</li></ul><p>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us&nbsp;</a></p>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>修正方法 - IO実行中に優先度の低いコマンドが頻繁に挿入されると、ドライブがランダムにオフラインになる可能性があります。</li></ul><p>詳しくは、HPEカスタマーアドバイザリ: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us </a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</li></ul><p>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us&nbsp;</a></p>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000960RXRQK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001920RXRRH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003840RXRRK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RXRQL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RXRRL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RXRRN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680RYEWD","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Critical"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"351d50a2bba345ebbd72893c5d1e177f"}]},{"ProductId":"aa9211e645514db69ecc4a92d0863429","Versions":[{"DeviceClass":"3653aa90-7089-453a-899c-792827a50d67","Devices":{"Device":[{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000049535320","Version":"1.24"},{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00004e564d65","Version":"1.24"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains firmware for ProLiant Gen10 NVMe storage backplanes. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、ProLiant Gen10Plus NVMeストレージバックプレーンのファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains firmware for ProLiant Gen10 NVMe storage backplanes. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"37637","DateModified":"2022-07-08T11:47:29","FileList":["ISS_NVMe_BP_PIC_flashV1B24.xml","ISS_NVMe_BP_PIC_flashV1B24_signed.hex","payload.json"],"MD5Sum":"6ece3524972bf147229b1f5f043ae0a2","Name":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","Release":"2022-07-08T11:43:54","Revision":"E","SHA1Sum":"633b896a37fa45ad5cd071ecf6e21a400012eee5","SHA256Sum":"78af2e9576979b534a8e4482664905540d6f2edd76f71f1afb123372a789d402","Size":"36KB","TargetGUIDs":["00000000-0000-0000-0000-000049535320","00000000-0000-0000-0000-00004e564d65"],"TypeOfChange":"1","Version":"1.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - Gen10 NVMe Backplane PIC Firmware"},{"Lang":"ja","Value":"ファームウェアパッケージ - Gen10 NVMe Backplane PICファームウェア"},{"Lang":"cn","Value":"Firmware Package - Gen10 NVMe Backplane PIC Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"NVMe Backplane","TargetGUID":"00000000-0000-0000-0000-00004e564d65","Type":"pic"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2022-08-07T10:20:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support HPE ProLiant DL325 Gen10 Plus Server</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>HPE ProLiant DL325 Gen10 Plusサーバーをサポート</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support HPE ProLiant DL325 Gen10 Plus Server</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.24"},{"ReleaseNotes":[{"Enhancements":"<p>Support ESXi8.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support ESXi8.0</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support ESXi8.0</p>","Fixes":"","Lang":"cn"}],"Version":"1.24"}],"SWKeys":[{"Name":"NVMePIC-Gen10","SWKeyExpectedPath":"firmware:nvmebackplane"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"fd4644ff6898456b8bf5d3a92e550bfa"}]},{"ProductId":"3ac61ed209fd49fb908341fa7b77c3ea","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"Lang":"cn","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility CLIは、サポートされているドライブのSmartSSD Wear Gauge情報の提供を含む、SmartアレイおよびSmartRAIDコントローラーとサポートされているデバイスのためのコマンドラインベースのディスク構成プログラムです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[{"Lang":"en","Value":"<p>Running SSADUCLI<br />------------------------------------------------------------------------<br />To run the command-line application:&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp; Open a command prompt and change directory (cd) to the location<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; where SSADUCLI is installed.&nbsp; This is commonly<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; C:\\Program Files\\Smart Storage Administrator\\ssaducli\\bin.<br />&nbsp;&nbsp; To generate a diagnostic report, enter the following command:</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -f adu-report.zip</p><p>&nbsp;&nbsp; To generate a SmartSSD Wear gauge report, enter the following command:</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -ssdrpt -f ssd-report.zip<br />&nbsp;&nbsp;<br />&nbsp;&nbsp; More options can be found by &quot;ssaducli -help&quot;.<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />Additional Notes<br />----------------<br />Both the diagnostic and SmartSSD wear gauge reports are generated in compressed<br />&nbsp; (ZIP) format.</p><p>The diagnostic report output archive contains the following files:</p><p>&nbsp;&nbsp; * ADUReport.txt&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in text format<br />&nbsp;&nbsp; * ADUReport.xml&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in XML format<br />&nbsp;&nbsp; * ADUReport.htm&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; HTML viewer for diagnostic report<br />&nbsp;&nbsp; * report.checksum&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; checksum file<br />&nbsp;&nbsp; * SlotX.txt (SlotX.old)&nbsp; =&gt; Controller serial output log</p><p>&nbsp;&nbsp; Note: The serial output log file(s) are only available if the &quot;HPE Smart<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Array SAS/SATA Event Notification Service&quot; is installed and running.</p><p>&nbsp;&nbsp; To view the diagnostic report in a browser, extract the ADUReport.htm. Open<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ADUReport.htm in the browser.</p><p>The SmartSSD wear gauge report output archive contains the following files:</p><p>&nbsp;&nbsp; * SmartSSDWearGaugeReport.txt&nbsp; =&gt; SmartSSD wear gauge report in text format<br />&nbsp;&nbsp; * SmartSSDWearGaugeReport.json =&gt; SmartSSD wear gauge report in JSON format<br />&nbsp;&nbsp; * SmartSSDWearGaugeReport.htm&nbsp; =&gt; HTML viewer for the JSON wear gauge report</p><p>&nbsp;&nbsp; To view the SmartSSD wear gauge report in a browser, extract the<br />&nbsp;&nbsp; SmartSSDWearGaugeReport.json, SmartSSDWearGaugeReport.htm files to a<br />&nbsp;&nbsp; directory (both files must reside in the same directory).&nbsp; Open<br />&nbsp;&nbsp; SmartSSDWearGaugeReport.htm in the browser.</p><p>Known Issues<br />------------<br />* When installing the 32-bit version of SSADUCLI on a system that has a<br />&nbsp; 64-bit (x64) version of SSADUCLI installed, please uninstall the 64-bit<br />&nbsp; version first. Failing to uninstall the 64-bit version will cause the 32-bit<br />&nbsp; installation to fail.</p>"},{"Lang":"ja","Value":"<p>SSADUCLIを実行します<br />------------------------------------------------------------------------<br />コマンド-ラインアプリケーションを実行します。   <br />   コマンドプロンプトを開いて<br />      SSADUCLIがインストールされているディレクトリに移動（cd）します。  これは通常<br />         C:\\Program Files\\Smart Storage Administrator\\ssaducli\\binです。<br />   * 診断レポートを生成するには、次のコマンドを実行します。</p><p>       ssaducli -f adu-report.zip</p><p>   SmartSSD Wear gaugeレポートを生成するには、次のコマンドを実行します。</p><p>       ssaducli -ssdrpt -f ssd-report.zip<br />  <br />   \"ssaducli -help\"によって、他のオプションを見つけることができます。<br />      <br />追加の注意<br />----------------<br />診断およびSmartSSD Wear gaugeは、圧縮（ZIP）形式でレポートを<br />  生成します。</p><p>診断レポート出力アーカイブには以下のファイルが含まれています。</p><p>   * ADUReport.txt          =>テキスト形式の診断レポート<br />   * ADUReport.xml          =>XML形式の診断レポート<br />   * ADUReport.htm          =>診断レポート用HTMLビューアー<br />   * report.checksum        =>チェックサムファイル<br />   * SlotX.txt (SlotX.old) =>コントローラーのシリアル出力ログ</p><p>   注記：シリアル出力ログファイルは\"HPE Smart <br />         Array SAS/SATA Event Notification service\"がインストールされ、実行されている場合のみ利用可能です。</p><p>   ブラウザーで診断レポートを参照するには、ADUReport.htmを抽出します。ブラウザーで<br />      ADUReport.htmを開きます。</p><p>SmartSSD wear gaugeレポート出力アーカイブには以下のファイルが含まれています。</p><p>   * SmartSSDWearGaugeReport.txt  =>テキスト形式のSmartSSD wear gaugeレポート<br />   * SmartSSDWearGaugeReport.json =>JSON形式のSmartSSD wear gaugeレポート<br />   * SmartSSDWearGaugeReport.htm  =>JSON wear gaugeレポート用のHTMLビューアー</p><p>   ブラウザーでSmartSSD Wear Gaugeレポートファイルを表示するには、<br />   SmartSSDWearGaugeReport.json,SmartSSDWearGaugeReport.htmファイルを<br />   ディレクトリに抽出します。（両方のファイルが同じディレクトリに存在する必要があります。）  ブラウザーで<br />   SmartSSDWearGaugeReport.htmを開きます。</p><p>既知の問題点<br />------------<br />* 32ビットバージョンのSSADUCLIを<br />  64ビットバージョン（x64）のSSADUCLIがインストールされたシステムにインストールする場合には、最初に<br />  64ビットバージョンをアンインストールします。64ビットバージョンのアンインストールに失敗すると、32ビットのインストールに<br />  失敗する原因となります。</p>"},{"Lang":"cn","Value":"<p>Running SSADUCLI<br />------------------------------------------------------------------------<br />To run the command-line application:&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp; Open a command prompt and change directory (cd) to the location<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; where SSADUCLI is installed.&nbsp; This is commonly<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; C:\\Program Files\\Smart Storage Administrator\\ssaducli\\bin.<br />&nbsp;&nbsp; To generate a diagnostic report, enter the following command:</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -f adu-report.zip</p><p>&nbsp;&nbsp; To generate a SmartSSD Wear gauge report, enter the following command:</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -ssdrpt -f ssd-report.zip<br />&nbsp;&nbsp;<br />&nbsp;&nbsp; More options can be found by &quot;ssaducli -help&quot;.<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />Additional Notes<br />----------------<br />Both the diagnostic and SmartSSD wear gauge reports are generated in compressed<br />&nbsp; (ZIP) format.</p><p>The diagnostic report output archive contains the following files:</p><p>&nbsp;&nbsp; * ADUReport.txt&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in text format<br />&nbsp;&nbsp; * ADUReport.xml&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in XML format<br />&nbsp;&nbsp; * ADUReport.htm&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; HTML viewer for diagnostic report<br />&nbsp;&nbsp; * report.checksum&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; checksum file<br />&nbsp;&nbsp; * SlotX.txt (SlotX.old)&nbsp; =&gt; Controller serial output log</p><p>&nbsp;&nbsp; Note: The serial output log file(s) are only available if the &quot;HPE Smart<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Array SAS/SATA Event Notification Service&quot; is installed and running.</p><p>&nbsp;&nbsp; To view the diagnostic report in a browser, extract the ADUReport.htm. Open<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ADUReport.htm in the browser.</p><p>The SmartSSD wear gauge report output archive contains the following files:</p><p>&nbsp;&nbsp; * SmartSSDWearGaugeReport.txt&nbsp; =&gt; SmartSSD wear gauge report in text format<br />&nbsp;&nbsp; * SmartSSDWearGaugeReport.json =&gt; SmartSSD wear gauge report in JSON format<br />&nbsp;&nbsp; * SmartSSDWearGaugeReport.htm&nbsp; =&gt; HTML viewer for the JSON wear gauge report</p><p>&nbsp;&nbsp; To view the SmartSSD wear gauge report in a browser, extract the<br />&nbsp;&nbsp; SmartSSDWearGaugeReport.json, SmartSSDWearGaugeReport.htm files to a<br />&nbsp;&nbsp; directory (both files must reside in the same directory).&nbsp; Open<br />&nbsp;&nbsp; SmartSSDWearGaugeReport.htm in the browser.</p><p>Known Issues<br />------------<br />* When installing the 32-bit version of SSADUCLI on a system that has a<br />&nbsp; 64-bit (x64) version of SSADUCLI installed, please uninstall the 64-bit<br />&nbsp; version first. Failing to uninstall the 64-bit version will cause the 32-bit<br />&nbsp; installation to fail.</p>"}],"Files":[{"Bytes":"3568288","DateModified":"2025-12-18T05:38:12","FileList":["cp069347.xml","cpqsetup.exe","cp_data.xml","genericmsi.dll","SSADU66080_X64.msi"],"MD5Sum":"b7e9954202339960aa021e4ee703bf09","Name":"cp069347.exe","Release":"2025-12-18T05:36:21","Revision":"","SHA1Sum":"ce7766f47f05f8717935659d2da7466cef651bd6","SHA256Sum":"a9abb8a0e4ff578cd78339fd399be725e3cbc80892fc8f3fe2146d7e9c15a501","Size":"3MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecdf9a8250"],"TypeOfChange":"1","Version":"6.60.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p> From that drive and directory, execute the downloaded file.</p><p> Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<p> そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> [インストール]ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p> From that drive and directory, execute the downloaded file.</p><p> Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64ビット for Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:16:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.</li></ul>","Lang":"cn"}],"Version":"6.50.13.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>RC drop 6.60.8.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RC drop 6.60.8.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>RC drop 6.60.8.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.60.8.0"}],"SWKeys":[{"Name":"ssaducli.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssaducli\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"bca28cc15a484d30b263b703e9e833ce"}]},{"ProductId":"65980a419afd45d6b2067bb6166a4282","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、VO015360KYDNB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;&nbsp;VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong>&nbsp;</p><ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />      オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNB ドライブ<br /><br /><strong>リリースバージョンおよび/または日付:</strong><br />      HPK6<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />      HPK5<br /><br /><strong>前のファームウェアバージョン：</strong><br />      HPK5<br /><br /><strong>ファームウェアの依存関係：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題：</strong> </p><ul><li>以前のファームウェアバージョンHPK5では、修正不可能なマシンチェック例外 (UMCE) が発生する可能性があります。ファームウェアバージョンを少なくともHPK6へアップデートすることが推奨されます。</li></ul><p><strong>既知の問題点：</strong><br />      なし</p>"}],"Files":[{"Bytes":"22542855","DateModified":"2025-03-06T20:13:22","FileList":["/CP065946_BUILD_9.data","/CP065946.vmexe64","/CP065946.vmfile","/CP065946_VMw.zip","/CP065946.xml","/payload.json","/CP065946_VMw.zip/index.xml","/CP065946_VMw.zip/vendor-index.xml","/CP065946_VMw.zip/metadata.zip","/CP065946_VMw.zip/vib20/CP065946/HPE_bootbank_CP065946_HPK6.9-8.0.0.20613240.vib","/CP065946_VMw.zip/metadata.zip/vendor-index.xml","/CP065946_VMw.zip/metadata.zip/vmware.xml","/CP065946_VMw.zip/metadata.zip/vibs/CP065946-5694786743774334663.xml","/CP065946_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065946_HPK6.9-8.0.0.20613240.xml"],"MD5Sum":"a728e2595af7a6eb83262ef33d7faf80","Name":"CP065946.zip","Release":"2025-03-06T20:12:36","Revision":"B","SHA1Sum":"bc94554e0bcaa09ceeb705005715b6010158ea17","SHA256Sum":"58ff533c44fc939fe0551c242b5628c862dfcbd6dd5afa78b783a77b31a0e039","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"2","Version":"HPK6","VibList":[{"Name":"CP065946","Version":"HPK6.9-8.0.0.20613240"}]}],"Installation":{"Command":"CP040631.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi  -  VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO001920KYDMT","TargetGUID":"562340a5-304f-3130-3932-304b59444d54","Type":"nvme"},{"Id":"VO003840KYDMV","TargetGUID":"562340a5-304f-3330-3834-304b59444d56","Type":"nvme"},{"Id":"MO001600KYDMU","TargetGUID":"4d2340a5-304f-3130-3630-304b59444d55","Type":"nvme"},{"Id":"MO006400KYDND","TargetGUID":"4d2340a5-304f-3630-3430-304b59444e44","Type":"nvme"},{"Id":"VO015360KYDNB","TargetGUID":"562340a5-304f-3531-3336-304b59444e42","Type":"nvme"},{"Id":"VO007680KYDNA","TargetGUID":"562340a5-304f-3730-3638-304b59444e41","Type":"nvme"},{"Id":"MO003200KYDNC","TargetGUID":"4d2340a5-304f-3330-3230-304b59444e43","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:31:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA will published later at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>以前のファームウェアバージョンHPK5では、修正不可能なマシンチェック例外 (UMCE) が発生する可能性があります。ファームウェアバージョンを少なくともHPK6へアップデートすることが推奨されます。</li><li>詳しくは、CAが後で次のURLで公開されます。<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA will published later at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"HPK6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK6"}],"SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a0bbf3db79104da6bc975c6db1959f9d"}]},{"ProductId":"0740887082f84323b1025ff5aaaeefed","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Ubuntu&nbsp;Linux&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Ubuntu&nbsp;Linux&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5202156","DateModified":"2025-08-03T01:10:44","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-1.1/CP067331.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-1.1/HPG1_PM893.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067331.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067331.scexe"],"MD5Sum":"4293646af09a0e470a86c588bf6be695","Name":"firmware-hdd-abd133f0de_0HPG1-1.1_amd64.deb","Release":"2025-08-03T06:02:07","Revision":"","SHA1Sum":"238e9e0d43b42ebe096d97f009bf3565b4cbdb06","SHA256Sum":"f9a159d0312c72eee19426d57e88ebed60ca1f08b0d21050955809f582455ed2","Size":"4MB","TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040346.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK001920GZXQV","TargetGUID":"562340a5-304b-3130-3932-30475a585156","Type":"sata"},{"Id":"VK003840GZXRH","TargetGUID":"562340a5-304b-3330-3834-30475a585248","Type":"sata"},{"Id":"VK007680GZXRT","TargetGUID":"562340a5-304b-3730-3638-30475a585254","Type":"sata"},{"Id":"VK000960GZXQU","TargetGUID":"562340a5-304b-3030-3936-30475a585155","Type":"sata"},{"Id":"VK000480GZXRF","TargetGUID":"562340a5-304b-3030-3438-30475a585246","Type":"sata"},{"Id":"VK000240GZXRU","TargetGUID":"562340a5-304b-3030-3234-30475a585255","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:56:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7aa582b22781487ead53b5b369c9367e"}]},{"ProductId":"3f71b29f23c14fcb8f1f4cc9ac53400c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"4419552","DateModified":"2025-11-16T09:47:20","FileList":["cp068745.xml","cpqsetup.exe","HVLPeAsseFD2.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"355d322b336cecb6cbc14eb11cf36b03","Name":"cp068745.exe","Release":"2025-11-16T09:40:57","Revision":"H","SHA1Sum":"4300ba45137ca9d5ca2f23d343fe5b6de983305d","SHA256Sum":"e494903936f32cfdaf01a3849a9feba1b0c1d68686338fef8b1d750d489d32f5","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB008000JWRTD ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000JWRTD","TargetGUID":"4d2340a5-3042-3830-3030-304a57525444","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T07:20:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bcfbab82abed4237b56f417784cb3e5b"}]},{"ProductId":"92d9bf17d9ef471e842a80e42a41ec72","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB008000GWRTC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4409928","DateModified":"2025-11-17T10:28:15","FileList":["cp068746.xml","cpqsetup.exe","HVLPeAaseFG1.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"9d979e4f1670869e7ffb397ec0c13abe","Name":"cp068746.exe","Release":"2025-11-17T10:23:04","Revision":"K","SHA1Sum":"5b98f2c5c86f788d1ee86cf7b3d3e7eadab8406b","SHA256Sum":"e65405412cc21b955e9b59950e25c11f464ac9672dd8254d11cbcd639852df39","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWRTC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB008000GWRTCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000GWRTC","TargetGUID":"4d2340a5-3042-3830-3030-304757525443","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:25:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"70a95b0733094a948f37a598b20428eb"}]},{"ProductId":"c797fcf50c574d47a553575e505c1d9d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6891724","DateModified":"2025-07-31T11:58:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-1.1/CP067325.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-1.1/MPK78H5Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067325.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067325.scexe"],"MD5Sum":"ec731434e972f65a5a3f277d5e700856","Name":"firmware-hdd-e320db791d_0MPK78H5Q-1.1_amd64.deb","Release":"2025-07-31T16:49:21","Revision":"","SHA1Sum":"e6d6898ce426b73ed47da39d151449364f8509c2","SHA256Sum":"81eca342e24fe142e2089c4b7afd89c1b11c886814aee9946888873c1a309815","Size":"6MB","TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3 and MZXL57T6HALA-000H3 Drives"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3 and MZXL57T6HALA-000H3 Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3 and MZXL57T6HALA-000H3 Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXL515THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3135-54486d0092b3","Type":"nvme"},{"Id":"MZXL512THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3132-544895b51a17","Type":"nvme"},{"Id":"MZXL57T6HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3754-364820f1a5c1","Type":"nvme"},{"Id":"MZXL56T4HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3654-34482ab7fb8f","Type":"nvme"},{"Id":"MZXL53T8HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-38483310a47b","Type":"nvme"},{"Id":"MZXL53T2HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-324884d9e9f5","Type":"nvme"},{"Id":"MZXL51T9HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-3948e450274f","Type":"nvme"},{"Id":"MZXL51T6HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-36487a9b1618","Type":"nvme"},{"Id":"MZXL5960HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3936-304894dc03d2","Type":"nvme"},{"Id":"MZXL5800HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3830-3048d90154e8","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:25:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"}],"SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7ccd917ffc0a40dd8628f9c92b92d3dc"}]},{"ProductId":"c02f997871554705a1c6e597965673df","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U37_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11689981","DateModified":"2026-01-12T00:59:41","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.62_2026_01_09-1.1/CP070253.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.62_2026_01_09-1.1/U37_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070253.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070253.scexe"],"MD5Sum":"a850f3675f379f41d940cd438f850130","Name":"firmware-system-u37-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-12T06:50:44","Revision":"","SHA1Sum":"ab4b84f88d44080018ddaf9ba45243d3af8f7b21","SHA256Sum":"4c6660fb21277e4ed9da2ccbebc878d24192b007767b434100a27970ad6b3029","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>RPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL230k Gen10 (U37) Server"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL230k Gen10 (U37)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL230k Gen10 (U37) Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:47:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e866eae7b1a6455fb288831ac8ca6b55"}]},{"ProductId":"710acbec2a70445381651a2e1f3c55ab","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."},{"Lang":"ja","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."},{"Lang":"cn","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"}],"Files":[{"Bytes":"2040782","DateModified":"2025-10-22T10:59:35","FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.3.58.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.58.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.58.0","./usr/lib64/libibverbs/libmlx5-rdmav57.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.58.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.25.58.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.58.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/mlnx-ofa_kernel","./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/perftest","./usr/share/doc/packages/perftest/COPYING","./usr/share/doc/packages/perftest/README","./usr/share/doc/packages/perftest/runme","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"MD5Sum":"dd3a54a7b7f07e2a7790e81bf520eb4a","Name":"mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm","Release":"2025-10-22T08:47:04","Revision":"","SHA1Sum":"d632f2deba59163b698edad0811d4a2540462971","SHA256Sum":"15eadb51b14308b7a3aed7776cd9e784c65a4f0aa92fed4954a7c73b6fa7a807","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"25.07-0.9.7.0"},{"Bytes":"2668260","DateModified":"2025-10-22T10:54:28","FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/compat","./lib/modules/6.4.0-150700.51-default/updates/compat/mlx_compat.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers","./lib/modules/6.4.0-150700.51-default/updates/drivers/block","./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd","./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd/rnbd-client.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd/rnbd-server.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/fwctl.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/efa","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/erdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/erdma/erdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/irdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mana","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mthca","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qedr","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qib","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/usnic","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rxe","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/siw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/iser","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/isert","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srp","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/host","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/target","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa","./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.4.0-150700.51-default/updates/net","./lib/modules/6.4.0-150700.51-default/updates/net/9p","./lib/modules/6.4.0-150700.51-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/mlxdevm","./lib/modules/6.4.0-150700.51-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/6.4.0-150700.51-default/updates/net/rds","./lib/modules/6.4.0-150700.51-default/updates/net/rds/rds_rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/smc","./lib/modules/6.4.0-150700.51-default/updates/net/smc/smc.ko","./lib/modules/6.4.0-150700.51-default/updates/net/smc/smc_diag.ko","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"MD5Sum":"acede0b0a55ef11aafb23afff35efdcf","Name":"mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150700.51-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm","Release":"2025-10-22T08:47:04","Revision":"","SHA1Sum":"4f1d01d66a8b76450840b0ba24a717d28456d7ad","SHA256Sum":"10e5341620f011a07081577449ffe36c23230cb3e9473f30dfe8dfcb76dddd6e","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"25.07-0.9.7.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.07&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br /><br />To install or upgrade the driver:<br />If using 6.4.0_150700.48-default kernel or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150700.51-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.07&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br /><br />To install or upgrade the driver:<br />If using 6.4.0_150700.48-default kernel or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150700.51-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.07&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br /><br />To install or upgrade the driver:<br />If using 6.4.0_150700.48-default kernel or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150700.51-OFED.25.07.0.9.7.1.sles15sp7.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for SUSE LINUX Enterprise Server 15 SP7 (AMD64/EM64T)"},{"Lang":"ja","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for SUSE LINUX Enterprise Server 15 SP7 (AMD64/EM64T)"},{"Lang":"cn","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for SUSE LINUX Enterprise Server 15 SP7 (AMD64/EM64T)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"1023","SubDev":"0002","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102315b30002","Type":"pci","Ven":"15B3"},{"Dev":"1023","SubDev":"0006","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102315b30006","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1021","SubDev":"0073","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30073","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0086","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30086","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30074","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0085","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30085","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-07T12:13:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.04-0.6.1.1:</strong></p><ul><li>Trust Lockdown Health Syndrome: Added a new health syndrome for trust lockdown and expose the CRR bit in the health buffer. When the CRR bit is set, it indicates that the syndrome requires a cold reset for recovery.</li><li>A Single PTP Device per Hardware Clock: PHC is typically shared across multiple functions. Currently, the driver creates a separate PTP device for each network interface sharing the same PHC, resulting in redundancy and added complexity. To address this, a single PTP device is now created to represent the shared PHC when operating in real-time mode.</li><li>Log IB State Transitions: Enhanced visibility into IB device state transitions by adding log messages to the kernel log (dmesg). Each time an IB device changes state, a corresponding message will be logged. For example: &quot;mlx5_0: Port: 1 Link DOWN&quot;.</li><li>Optional-counters Binding Support and New Packets/bytes Counters: Previously, optional counters were available only on a per-link basis. This release introduces the ability to bind optional counters to a specific counter object, enabling users to track optional counters across a specific QP group. Support is provided for both automatic and manual binding modes. In both cases, the optional counters that are bound to the QP are those currently configured on the link at the time of binding. Additionally, four new optional counters that track RDMA ingress and egress traffic are introduced: rdma_tx_bytes; rdma_tx_packets; rdma_rx_bytes; rdma_rx_packets. This functionality is exposed to users via the iproute2 package, which must be updated to support this feature.</li><li>User CAPability (UCAP) API: The User CAPability (UCAP) API introduces a mechanism for creating user contexts with specific firmware privileges. It offers fine-grained control over firmware features by exposing each capability as a character device with root-level read-write access. Root processes can grant users these privileges by allowing access to the corresponding character devices. When a user context is created using a UCAP file descriptor, it inherits the associated privileges. For mlx5, two UCAP character devices are provided, and any user context opened with at least one of them is treated as privileged. To guarantee the execution of privileged commands, non-privileged commands are restricted when a privileged user is active on the device.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.04-0.6.1.1:</strong></p><ul><li>Buffer initialization became a performance bottleneck during the allocation of large buffers, typically when using a high number of QPs with large message sizes. The root cause was the inefficient use of rand(). This has been resolved by replacing it with a faster pseudo-random algorithm.</li><li>A potential deadlock that could occur during the handling of peer memory registration failures.</li><li>The following error occurred when switching to SwitchDev mode: &quot;mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)&quot;</li><li>A sysfs issue that occurred when accessing hardware counters from within a namespace.</li><li>&quot;ibstat&quot; would fail and crash when encountering a non-RoCE/IB device, preventing it from displaying information for the remaining valid RoCE/IB devices.</li><li>Bandwidth degradation in cases of high number of QPs, where polling only 16 CQEs per iteration may not be sufficient to process all completions in time.</li><li>A race condition between firmware syndrome report and driver initialization during boot.</li><li>The driver failed to load when a firmware syndrome was detected during boot.</li><li>The mlnx_tune -l command did not list several operating systems that were in fact supported.</li><li>The kernel did not define TCA_TUNNEL_KEY_ENC_SRC_PORT. To align offload behavior with non-offload, the OVS community introduced a commit ( netdev-offload-tc: Fix offload of tunnel key tp_src) that causes offload to fail if this tunnel attribute is used. Now, any rule with a tunnel set action that includes a tunnel source port can no longer be offloaded.</li><li>LLDP traffic from VFs or BF host PFs was not reaching the representor kernel interfaces.</li><li>Flows where both the inner and outer destination (dst) and/or source (src) MAC addresses were rewritten to the same value, the outer MAC address rewrite was ignored, leading to an outer MAC address of 00:00:00:00:00:00.</li><li>Enabling sFlow with OVN caused OVS to crash.</li><li>OVS crashed unexpectedly after DPUs repeatedly broadcast the error message &ldquo;packet with own source address.&rdquo;</li><li>Changing the hw-offload setting from true to false while ports were configured led to errors reported in the OVS log.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン25.04-0.6.1.1には、次の新機能と変更が含まれています。</strong></p><ul><li>トラストロックダウンヘルスシンドローム：トラストロックダウン用の新しいヘルスシンドロームを追加し、ヘルスバッファー内のCRRビットを公開します。CRRビットが設定されている場合、シンドロームの回復にはコールドリセットが必要であることを示しています。</li><li>ハードウェアクロックごとに1つのPTPデバイス：PHCは通常、複数の機能間で共有されます。現在、ドライバーは同じPHCを共有するネットワークインターフェイスごとに個別のPTPデバイスを作成するため、冗長性があり、複雑さが増しています。この問題を解決するために、リアルタイムモードで動作しているときに共有されたPHCを表す1つのPTPデバイスが作成されるようになりました。</li><li>IB状態遷移のログ：カーネルログ (dmesg) にログメッセージを追加することで、IBデバイスの状態遷移の可視性が向上しました。IBデバイスの状態が変化するたびに、対応するメッセージが記録されます。例えば、\"mlx5_0: Port: 1 Link DOWN\"などです。</li><li>オプションカウンターのバインディングサポートと新しいパケット/バイトカウンター：以前は、オプションカウンターはリンクごとにのみ使用可能でした。このリリースでは、オプションカウンターを特定のカウンターオブジェクトにバインドする機能が導入され、ユーザーは特定のQPグループ全体でオプションカウンターを追跡できるようになりました。自動バインディングモードと手動バインディングモードの両方がサポートされます。どちらの場合も、QPにバインドされるオプションカウンターは、バインド時にリンク上で現在設定されているカウンターです。さらに、RDMAのイングレストラフィックとイーグレストラフィックを追跡する4つの新しいオプションカウンター (rdma_tx_bytes、rdma_tx_packets、rdma_rx_bytes、rdma_rx_packets) が導入されました。この機能はiproute2パッケージを介してユーザーに公開されますが、この機能をサポートするにはこのパッケージをアップデートする必要があります。</li><li>User CAPability (UCAP) API：User CAPability (UCAP) APIは、特定のファームウェア権限を持つユーザーコンテキストを作成するためのメカニズムを導入します。各機能をルートレベルの読み取り/書き込みアクセスを持つキャラクター型デバイスとして公開することで、ファームウェア機能に対するきめ細かな制御を実現します。ルートプロセスでは、対応するキャラクター型デバイスへのアクセスを許可することで、ユーザーにこれらの権限を付与できます。UCAPファイル記述子を使用してユーザーコンテキストが作成されると、ユーザーコンテキストは関連付けられている権限を継承します。mlx5の場合、2つのUCAPキャラクター型デバイスが提供され、そのうちの少なくとも1つを使用して開かれたユーザーコンテキストが特権として扱われます。特権コマンドの実行を保証するために、特権ユーザーがデバイス上でアクティブな場合、非特権コマンドが制限されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン25.04-0.6.1.1で修正されました。</strong></p><ul><li>メッセージサイズの大きい多数のQPを使用する場合など、大きなバッファーの割り当て中に、バッファーの初期化がパフォーマンスのボトルネックになっていました。根本的な原因は、rand() の非効率的な使用でした。この問題は、より高速な疑似ランダムアルゴリズムに置き換えることで解決されました。</li><li>ピアメモリ登録の失敗の処理中に発生する可能性のあるデッドロック。</li><li>SwitchDevモードに切り替える際に次のエラーが発生しました。\"mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)\"</li><li>名前空間内からハードウェアカウンターにアクセスする際に発生したsysfsの問題。</li><li>\"ibstat\"は、RoCE/IB以外のデバイスを見つけると失敗してクラッシュし、残りの有効なRoCE/IBデバイスの情報を表示できなくなります。</li><li>QPの数が多い場合に帯域幅が低下し、反復ごとに16個のCQEをポーリングするだけでは、すべての完了を時間内に処理するのに十分ではない可能性があります。</li><li>ブート中のファームウェアシンドロームレポートとドライバー初期化の間の競合状態。</li><li>ブート中にファームウェアシンドロームが検出されたため、ドライバーのロードに失敗しました。</li><li>mlnx_tune -lコマンドでは、実際にサポートされているいくつかのオペレーティングシステムがリストされませんでした。</li><li>カーネルはTCA_TUNNEL_KEY_ENC_SRC_PORTを定義しませんでした。オフロードの動作を非オフロードと一致させるために、OVSコミュニティは、このトンネル属性が使用されている場合にオフロードが失敗するコミット (netdev-offload-tc：トンネルキーtp_srcのオフロードを修正) を導入しました。これで、トンネルのソースポートを含むトンネルセットアクションを持つすべてのルールはオフロードできなくなります。</li><li>VFまたはBFホストPFからのLLDPトラフィックが、リプレゼンターカーネルインターフェイスに到達していませんでした。</li><li>内部と外部の両方の宛先 (dst) および/または送信元 (src) MACアドレスが同じ値に書き換えられたフローで、外部MACアドレスの書き換えは無視され、外部MACアドレスが00:00:00:00:00:00 になります。</li><li>OVNでsFlowを有効にすると、OVSがクラッシュしました。</li><li>DPUが\"packet with own source address\"というエラーメッセージを繰り返しブロードキャストした後、OVSが予期せずクラッシュしました。</li><li>ポートの設定中にhw-offload設定をtrueからfalseに変更すると、OVSログにエラーが報告されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.04-0.6.1.1:</strong></p><ul><li>Trust Lockdown Health Syndrome: Added a new health syndrome for trust lockdown and expose the CRR bit in the health buffer. When the CRR bit is set, it indicates that the syndrome requires a cold reset for recovery.</li><li>A Single PTP Device per Hardware Clock: PHC is typically shared across multiple functions. Currently, the driver creates a separate PTP device for each network interface sharing the same PHC, resulting in redundancy and added complexity. To address this, a single PTP device is now created to represent the shared PHC when operating in real-time mode.</li><li>Log IB State Transitions: Enhanced visibility into IB device state transitions by adding log messages to the kernel log (dmesg). Each time an IB device changes state, a corresponding message will be logged. For example: &quot;mlx5_0: Port: 1 Link DOWN&quot;.</li><li>Optional-counters Binding Support and New Packets/bytes Counters: Previously, optional counters were available only on a per-link basis. This release introduces the ability to bind optional counters to a specific counter object, enabling users to track optional counters across a specific QP group. Support is provided for both automatic and manual binding modes. In both cases, the optional counters that are bound to the QP are those currently configured on the link at the time of binding. Additionally, four new optional counters that track RDMA ingress and egress traffic are introduced: rdma_tx_bytes; rdma_tx_packets; rdma_rx_bytes; rdma_rx_packets. This functionality is exposed to users via the iproute2 package, which must be updated to support this feature.</li><li>User CAPability (UCAP) API: The User CAPability (UCAP) API introduces a mechanism for creating user contexts with specific firmware privileges. It offers fine-grained control over firmware features by exposing each capability as a character device with root-level read-write access. Root processes can grant users these privileges by allowing access to the corresponding character devices. When a user context is created using a UCAP file descriptor, it inherits the associated privileges. For mlx5, two UCAP character devices are provided, and any user context opened with at least one of them is treated as privileged. To guarantee the execution of privileged commands, non-privileged commands are restricted when a privileged user is active on the device.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.04-0.6.1.1:</strong></p><ul><li>Buffer initialization became a performance bottleneck during the allocation of large buffers, typically when using a high number of QPs with large message sizes. The root cause was the inefficient use of rand(). This has been resolved by replacing it with a faster pseudo-random algorithm.</li><li>A potential deadlock that could occur during the handling of peer memory registration failures.</li><li>The following error occurred when switching to SwitchDev mode: &quot;mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)&quot;</li><li>A sysfs issue that occurred when accessing hardware counters from within a namespace.</li><li>&quot;ibstat&quot; would fail and crash when encountering a non-RoCE/IB device, preventing it from displaying information for the remaining valid RoCE/IB devices.</li><li>Bandwidth degradation in cases of high number of QPs, where polling only 16 CQEs per iteration may not be sufficient to process all completions in time.</li><li>A race condition between firmware syndrome report and driver initialization during boot.</li><li>The driver failed to load when a firmware syndrome was detected during boot.</li><li>The mlnx_tune -l command did not list several operating systems that were in fact supported.</li><li>The kernel did not define TCA_TUNNEL_KEY_ENC_SRC_PORT. To align offload behavior with non-offload, the OVS community introduced a commit ( netdev-offload-tc: Fix offload of tunnel key tp_src) that causes offload to fail if this tunnel attribute is used. Now, any rule with a tunnel set action that includes a tunnel source port can no longer be offloaded.</li><li>LLDP traffic from VFs or BF host PFs was not reaching the representor kernel interfaces.</li><li>Flows where both the inner and outer destination (dst) and/or source (src) MAC addresses were rewritten to the same value, the outer MAC address rewrite was ignored, leading to an outer MAC address of 00:00:00:00:00:00.</li><li>Enabling sFlow with OVN caused OVS to crash.</li><li>OVS crashed unexpectedly after DPUs repeatedly broadcast the error message &ldquo;packet with own source address.&rdquo;</li><li>Changing the hw-offload setting from true to false while ports were configured led to errors reported in the OVS log.</li></ul>","Lang":"cn"}],"Version":"25.04-0.6.1.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"cn"}],"Version":"25.07-0.9.7.0"}],"SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"f3969b4898734bd288179cdd2b5d71c0"}]},{"ProductId":"93312d51d8f7459ba48a2a8cbf6722a2","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Management"},{"Lang":"ja","Value":"ソフトウェア - マネジメント"},{"Lang":"cn","Value":"软件 - 管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."},{"Lang":"ja","Value":"Smart Storage Administrator CLIは、SmartアレイコントローラーおよびSmartRAIDコントローラー用のコマンドラインベースのディスク構成プログラムです。"},{"Lang":"cn","Value":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"16441581","DateModified":"2025-12-08T07:22:40","FileList":["/cp069350.xml","/MIS_bootbank_ssacli2_6.60.8.0-8.0.0.20613240.oem.vib","/ssacli2-component_6.60.8.0-8.0.0.20613240.zip","/ssacli2-component_6.60.8.0-8.0.0.20613240.zip/index.xml","/ssacli2-component_6.60.8.0-8.0.0.20613240.zip/vendor-index.xml","/ssacli2-component_6.60.8.0-8.0.0.20613240.zip/metadata.zip","/ssacli2-component_6.60.8.0-8.0.0.20613240.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.60.8.0-8.0.0.20613240.oem.vib","/ssacli2-component_6.60.8.0-8.0.0.20613240.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.60.8.0-8.0.0.20613240.zip/metadata.zip/vmware.xml","/ssacli2-component_6.60.8.0-8.0.0.20613240.zip/metadata.zip/vibs/ssacli2-6043021303605303551.xml","/ssacli2-component_6.60.8.0-8.0.0.20613240.zip/metadata.zip/bulletins/ssacli2-component_6.60.8.0-8.0.0.20613240.xml"],"MD5Sum":"3df17ad0c8e62258cb1482ad3dc4e5ad","Name":"cp069350.zip","Release":"2025-12-08T07:21:28","Revision":"","SHA1Sum":"50ffead3e1dd8484c70841dd9c88242cfc35f712","SHA256Sum":"c84450eef78fc26956a412d7ea61304b49645384a15dbecb04c255f2679c406b","Size":"15MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2026.03.01","VibList":[{"Name":"ssacli2","Version":"6.60.8.0-8.0.0.20613240.oem"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"ja","Value":"<p><strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li><li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li></ol><p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 8.0 for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) CLI Smartコンポーネントfor ESXi 8.0 for Gen10/Gen10 Plus/Gen11コントローラー"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 8.0 for Gen10/Gen10 Plus/Gen11 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"7100"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:22:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"cn"}],"Version":"2025.09.01"},{"ReleaseNotes":[{"Enhancements":"<p>New drop for 6.60.8.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>New drop for 6.60.8.0</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>New drop for 6.60.8.0</p>","Fixes":"","Lang":"cn"}],"Version":"2026.03.01"}],"SWKeys":[{"Name":"ssacli2-component:6.60.8.0-8.0.0.20613240","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.60.8.0-8.0.0.20613240.oem","SWKeyExpectedPath":"software:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL215n Gen10 Plus"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1decdc7a90514de49ce94757cbae9943"}]},{"ProductId":"5d636f95f482471a9bd020c928d3b4af","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_NS204i_1.2.14.1025","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1025_B.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1025"},{"DeviceName":"HPE_NS204i_1.2.14.1025","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1025_B.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1025"},{"DeviceName":"HPE_NS204i_1.2.14.1025","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1025_B.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1025"},{"DeviceName":"HPE_NS204i_1.2.14.1025","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1025_B.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1025"},{"DeviceName":"HPE_NS204i_1.2.14.1025","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1025_B.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900455","Version":"1.2.14.1025"}]},"MinimumActiveVersion":"1.2.14.1018","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r"},{"Lang":"ja","Value":"ユニバーサルファームウェアPLDMファイルfor HPE Gen12 Boot Controller NS204i-u、HPE Gen11 Boot Controller NS204i-u、NS204i-d、およびHPE Gen10 Plus Boot Controller NS204i-p、NS204i-d、NS204i-t、NS204i-r"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7379633","DateModified":"2026-01-21T03:37:17","FileList":["HPE_NS204i_1.2.14.1025_B.HPb","HPE_NS204i_1.2.14.1025_B.xml","payload.json"],"MD5Sum":"e0a387c5e45853b2ad174abfbcea7188","Name":"HPE_NS204i_1.2.14.1025_B.fwpkg","Release":"2026-01-21T03:34:16","Revision":"B","SHA1Sum":"5ed227b6724d319564d28532782666cee84e7060","SHA256Sum":"fedfe8b5a51c18bb354fb39ccf1a2f9209f89685c8f84c0770cee341e1d793f0","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900455"],"TypeOfChange":"1","Version":"1.2.14.1025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command.&nbsp; Download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager (SUM) を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。  iLOrestツールの最新バージョンをダウンロードします。</p><p>    ローカルホストOSの例：<br /><strong><em>    ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>     アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command.&nbsp; Download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE Gen12 Boot Controller NS204i-u、HPE Gen11 Boot Controller NS204i-u、NS204i-dおよびHPE Gen10 Plus Boot Controller NS204i-p、NS204i-d、NS204i-t、NS204i-r"},{"Lang":"cn","Value":"Firmware Package - HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"2241","SubDev":"0379","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"02F6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0380","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0455","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900455","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0310","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","Type":"pci","Ven":"1B4B"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-20T08:52:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>[HPE][WM]&nbsp;Controller &ldquo;EncryptionMode&rdquo; shows &ldquo;Disabled&rdquo; and Volume Encryption shows &ldquo;false&rdquo; state after replacing original encrypted drive with a new foreign drive.&nbsp;</li><li>[WM]&nbsp;Redfish Set EncryptionKey and EncryptionKeyIdentifier returned 200OK when CurrentEncryptionKey is not provided.</li><li>After completing the rebuilding with new drive, followed by powercycle, observed LocalKeyIdenitifer empty and PD2 goes into Foreign statey.&nbsp;</li><li>After Powercycle, PD2 goes into foreign state, once swapping PD1 with Locked(Foreign) from Other LKM configured system and Perform RTOFS on PD1.&nbsp;</li><li>After replacing LKM configured PD1 with different system Locked PD1, Rekey not working After RTOFS+Powercycle.</li><li>LKM Rekey Not working if single Character been provided in payload,also observed PD goes into Foreign state if single Char provided as Key in payload.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>[HPE][WM] 元の暗号化ドライブを新しい外部ドライブに交換した後に、コントローラーの“EncryptionMode”に“Disabled”と表示され、ボリューム暗号化に“false”状態が表示されます。 </li><li>[WM] CurrentEncryptionKeyが指定されていない場合に、Redfish Set EncryptionKeyおよびEncryptionKeyIdentifierが200OKを返しました。</li><li>新しいドライブで再構築を完了した後に、電源を再投入すると、LocalKeyIdenitiferが空になり、PD2が外部状態になることが観察されました。 </li><li>電源の再投入後、PD1を他のLKM構成システムからロック済み (外部) にスワップし、PD1でRTOFSを実行すると、PD2が外部状態になります。 </li><li>LKM構成のPD1を別のシステムのロック済みPD1に置き換えた後、RTOFS + 電源再投入後にキー再生成が機能しません。</li><li>ペイロードに単一の文字が指定されている場合に、LKMキー再生成が機能せず、さらにペイロードにキーとして単一の文字が指定されている場合に、PDが外部状態になることが観察されています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>[HPE][WM]&nbsp;Controller &ldquo;EncryptionMode&rdquo; shows &ldquo;Disabled&rdquo; and Volume Encryption shows &ldquo;false&rdquo; state after replacing original encrypted drive with a new foreign drive.&nbsp;</li><li>[WM]&nbsp;Redfish Set EncryptionKey and EncryptionKeyIdentifier returned 200OK when CurrentEncryptionKey is not provided.</li><li>After completing the rebuilding with new drive, followed by powercycle, observed LocalKeyIdenitifer empty and PD2 goes into Foreign statey.&nbsp;</li><li>After Powercycle, PD2 goes into foreign state, once swapping PD1 with Locked(Foreign) from Other LKM configured system and Perform RTOFS on PD1.&nbsp;</li><li>After replacing LKM configured PD1 with different system Locked PD1, Rekey not working After RTOFS+Powercycle.</li><li>LKM Rekey Not working if single Character been provided in payload,also observed PD goes into Foreign state if single Char provided as Key in payload.</li></ul>","Lang":"cn"}],"Version":"1.2.14.1025"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Fix SW key fail issue.&nbsp;https://jira-pro.it.hpe.com:8443/browse/IRP-26418</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Fix SW key fail issue.&nbsp;https://jira-pro.it.hpe.com:8443/browse/IRP-26418</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Fix SW key fail issue.&nbsp;https://jira-pro.it.hpe.com:8443/browse/IRP-26418</p>","Lang":"cn"}],"Version":"1.2.14.1025"}],"SWKeys":[{"Name":"03791590","SWKeyExpectedPath":"firmware"},{"Name":"03801590","SWKeyExpectedPath":"firmware"},{"Name":"02F61590","SWKeyExpectedPath":"firmware"},{"Name":"030E1590","SWKeyExpectedPath":"firmware"},{"Name":"04551590","SWKeyExpectedPath":"firmware"},{"Name":"030F1590","SWKeyExpectedPath":"firmware"},{"Name":"03101590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"2e00bae1236c4ce986309cc6acf06143"}]},{"ProductId":"1065be4a2b444fe1b0060c3a91fcbde2","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>&nbsp; &nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf) to (ixgbevf). Now we revert this change from (ixgbevf) to (<strong>hp</strong>-ixgbevf).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-ixgbevf and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbevf and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>    このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-ixgbevf）から（ixgbevf）に変更されました。この変更を（ixgbevf）から（<strong>hp</strong>-ixgbevf）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-ixgbevfとkmod-ixgbeareはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-ixgbevfによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>&nbsp; &nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf) to (ixgbevf). Now we revert this change from (ixgbevf) to (<strong>hp</strong>-ixgbevf).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-ixgbevf and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbevf and then install the updated RPM.</p>"}],"Files":[{"Bytes":"79881","DateModified":"2025-09-15T15:38:26","FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-ixgbevf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/1f","./usr/lib/.build-id/1f/18fb192386ab8195ef9d4edba98b450c0dfea9","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"MD5Sum":"7796be85e29f135b3ff9796c2557977f","Name":"kmod-hp-ixgbevf-5.1.6-1.rhel9u5.x86_64.rpm","Release":"2025-09-15T15:31:32","Revision":"","SHA1Sum":"af4a28bb6303c97b47efdab0907f426b1cf86b2f","SHA256Sum":"db84a9d964f1c3fb21aae5c4a7cd426e0883601df11ab1573be65a8f161e8a19","Size":"78KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"TypeOfChange":"1","Version":"5.1.6-1"},{"Bytes":"79915","DateModified":"2025-09-15T15:42:40","FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-ixgbevf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/50","./usr/lib/.build-id/50/6e82682bc0f1d4450d63be128954b2dc011529","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"MD5Sum":"8f6fdeecdfcbc8aeeef6846a78f914a5","Name":"kmod-hp-ixgbevf-5.1.6-1.rhel9u6.x86_64.rpm","Release":"2025-09-15T15:31:32","Revision":"","SHA1Sum":"3a5100b84e175c856b1ef2f141d0ca3e061d951c","SHA256Sum":"a0dad368fe8767856739657552ee289e3ed2cc36f2ee5ee016c353308d6321bd","Size":"78KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"TypeOfChange":"1","Version":"5.1.6-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"57ad","SubDev":"00FF","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad808600ff","Type":"pci","Ven":"8086"},{"Dev":"57B1","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57b180860003","Type":"pci","Ven":"8086"},{"Dev":"57AD","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad80860003","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-12T09:34:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product now adds support for E610 device.</li><li>This product now supports Red Hat Enterprise Linux 9.6.</li></ul>","Fixes":"<p>Known issue: Firmware OROM version displays incorrectly via &quot;esxcli network nic get -n interface&quot;.</p>","Lang":"en"},{"Enhancements":"<ul><li>この製品では、E610デバイスのサポートが追加されました。</li><li>この製品は、現在Red Hat Enterprise Linux 9.6をサポートします。</li></ul>","Fixes":"<p>既知の問題: 「esxcli network nic get -n interface」でファームウェアOROMバージョンが正しく表示されません。</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product now adds support for E610 device.</li><li>This product now supports Red Hat Enterprise Linux 9.6.</li></ul>","Fixes":"<p>Known issue: Firmware OROM version displays incorrectly via &quot;esxcli network nic get -n interface&quot;.</p>","Lang":"cn"}],"Version":"5.1.4-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"5.1.6-1"}],"SWKeys":[{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d5bd1b74a5d94cbcba4ce618c60fa4bb"}]},{"ProductId":"dab6093d4d7545e892501476a1f6d448","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3636800","DateModified":"2025-11-15T15:30:16","FileList":["cp068753.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WBCPssssASFD4.rel"],"MD5Sum":"0bbc66f85f4bdbc13f596790ecb82fc6","Name":"cp068753.exe","Release":"2025-11-15T15:25:10","Revision":"C","SHA1Sum":"c6c1f62b8b5d694d6bdb316c02ae8a370552eabd","SHA256Sum":"a218f3c924a286b8f3aff9bdc3ae0e3c5fd60023d934fb224f10ffc18fe46c68","Size":"3MB","TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MO006400JWUGB","TargetGUID":"4d2340a5-304f-3630-3430-304a57554742","Type":"sas"},{"Id":"MO003200JWUGA","TargetGUID":"4d2340a5-304f-3330-3230-304a57554741","Type":"sas"},{"Id":"MO001600JWUFV","TargetGUID":"4d2340a5-304f-3130-3630-304a57554656","Type":"sas"},{"Id":"EO001600JWUGE","TargetGUID":"452340a5-304f-3130-3630-304a57554745","Type":"sas"},{"Id":"MO000800JWUFU","TargetGUID":"4d2340a5-304f-3030-3830-304a57554655","Type":"sas"},{"Id":"EO000800JWUGD","TargetGUID":"452340a5-304f-3030-3830-304a57554744","Type":"sas"},{"Id":"MO000400JWUFT","TargetGUID":"4d2340a5-304f-3030-3430-304a57554654","Type":"sas"},{"Id":"EO000400JWUGC","TargetGUID":"452340a5-304f-3030-3430-304a57554743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:48:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、HPE Customer Bulletin: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、HPE Customer Bulletin: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cb7c7a062d0d46609b85b13dbdfe7f2b"}]},{"ProductId":"b4de54a776434c1baf230d968d3bb23f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4948224","DateModified":"2025-11-17T04:12:16","FileList":["cp068643.xml","cpqsetup.exe","HPG1PM893.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"25b989f7504c84f91a062d3ef786a9c8","Name":"cp068643.exe","Release":"2025-11-17T04:07:24","Revision":"D","SHA1Sum":"27cdd8ba2913c36c149dbd12fe2c97971b68564b","SHA256Sum":"c3b24244cd3265f4a995f24e5543a009d6d7f1b5336b5d7e4f572e9f32e97571","Size":"4MB","TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK001920GZXQV","TargetGUID":"562340a5-304b-3130-3932-30475a585156","Type":"sata"},{"Id":"VK003840GZXRH","TargetGUID":"562340a5-304b-3330-3834-30475a585248","Type":"sata"},{"Id":"VK007680GZXRT","TargetGUID":"562340a5-304b-3730-3638-30475a585254","Type":"sata"},{"Id":"VK000960GZXQU","TargetGUID":"562340a5-304b-3030-3936-30475a585155","Type":"sata"},{"Id":"VK000480GZXRF","TargetGUID":"562340a5-304b-3030-3438-30475a585246","Type":"sata"},{"Id":"VK000240GZXRU","TargetGUID":"562340a5-304b-3030-3234-30475a585255","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:11:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a8c1c0fb65e04e15a97628a36f6cffd7"}]},{"ProductId":"896ea0712e9c4853949ccb47860e6c63","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5875918","DateModified":"2025-09-17T11:32:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/BCHPC17M.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/CP068852.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068852.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068852.scexe"],"MD5Sum":"7bb7692892df49d1730a5577f77aa811","Name":"firmware-hdd-5dcf26fa42-HPD3-5.1.x86_64.rpm","Release":"2025-09-17T16:22:05","Revision":"E","SHA1Sum":"caed8742ed3070f3d8d75c5d401b41d2ffb7aa32","SHA256Sum":"395804142dcfc9ca7c0101a7d61f307ab725d632ac6417a3eb655e1ed873963a","Size":"5MB","TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP040329.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA、およびMO003200JWDLBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EO001600JWDKR","TargetGUID":"452340a5-304f-3130-3630-304a57444b52","Type":"sas"},{"Id":"MO001600JWDLA","TargetGUID":"4d2340a5-304f-3130-3630-304a57444c41","Type":"sas"},{"Id":"MO003200JWDLB","TargetGUID":"4d2340a5-304f-3330-3230-304a57444c42","Type":"sas"},{"Id":"EO000400JWDKP","TargetGUID":"452340a5-304f-3030-3430-304a57444b50","Type":"sas"},{"Id":"MO000400JWDKU","TargetGUID":"4d2340a5-304f-3030-3430-304a57444b55","Type":"sas"},{"Id":"EO000800JWDKQ","TargetGUID":"452340a5-304f-3030-3830-304a57444b51","Type":"sas"},{"Id":"MO000800JWDKV","TargetGUID":"4d2340a5-304f-3030-3830-304a57444b56","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:39:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7d25ddccca094465af5c279763967303"}]},{"ProductId":"6522bf51105244bfa55540a1e824854d","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051643.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component updates the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"このコンポーネントは、HPE Gen10 PlusサーバーのHPE Gen10 Plus Innovation Engine Firmwareをアップデートします。"},{"Lang":"cn","Value":"This component updates the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9052232","DateModified":"2025-11-14T03:36:22","FileList":["cp051643.compsig","cp051643.zip","cp069596.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"006ff698aa3b47b2cb6b2d057e6b5aa7","Name":"cp069596.exe","Release":"2025-11-14T03:34:43","Revision":"F","SHA1Sum":"b705b49ad24b0ac316df237c1975f14227b16910","SHA256Sum":"632968341a6337fbeebb4024a75965b644617e6e22c3a40d3b9af01ef29b49a1","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。<br /> </p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Plus Innovation Engine Firmware  for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Windows x64 - HPE Gen10 Plus Innovation Engineファームウェアfor HPE Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Plus Innovation Engine Firmware  for HPE Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T02:54:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(C) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision C if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p><p>Ver 1.0.0.22(C)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver 1.0.0.22と同等です。ファームウェアをバージョン1.0.0.22にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョンCにアップグレードする必要はありません。</p><p><strong>ファームウェアの依存関係:</strong></p><p> なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(C) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision C if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(F) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(F) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(F) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"}],"SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:sd:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"abd642129a204ef7a157ea1218dda1b5"}]},{"ProductId":"5525dd3ac4024adeb1f8ec72b9fd1236","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNLおよびEG002400JWJNN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"5122269","DateModified":"2025-09-17T11:45:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/CP068866.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/TA15SEE0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068866.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068866.scexe"],"MD5Sum":"a82e0dd804ac480610179a991fa517c1","Name":"firmware-hdd-852266afdf-HPD6-2.1.x86_64.rpm","Release":"2025-09-17T16:35:05","Revision":"B","SHA1Sum":"1ebfb22617bc4dfa29bc9d8fe385660f78e62222","SHA256Sum":"f919ff081a5d4dccf19206007cfe57312401a73fbf89ff041b186cbac33aa20f","Size":"4MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"CP041561.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG002400JWJNN","TargetGUID":"452340a5-3047-3230-3430-304a574a4e4e","Type":"sas"},{"Id":"EG001800JWJNL","TargetGUID":"452340a5-3047-3130-3830-304a574a4e4c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T20:17:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"56f020a0165144c8989c5eba4a4a494e"}]},{"ProductId":"cf7cb50c769b4b00ab89aa81d9fac797","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />     オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFEおよびVO003840RWUFFドライブ</p><p><strong>リリースバージョンおよび/または日付：</strong><br />     HPD8<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPD7<br /><br /><strong>前のファームウェアバージョン：</strong><br />     HPD7<br /><br /><strong>ファームウェアの関連性：</strong><br />     なし<br /> </p><p><strong>機能強化/新しい機能：</strong></p><p>     なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"}],"Files":[{"Bytes":"19027854","DateModified":"2025-03-06T05:40:36","FileList":["/CP065957_BUILD_5.data","/CP065957.vmexe64","/CP065957.vmfile","/CP065957_VMw.zip","/CP065957.xml","/payload.json","/CP065957_VMw.zip/index.xml","/CP065957_VMw.zip/vendor-index.xml","/CP065957_VMw.zip/metadata.zip","/CP065957_VMw.zip/vib20/CP065957/HPE_bootbank_CP065957_HPD8.5-1OEM.800.1.0.20613240.vib","/CP065957_VMw.zip/metadata.zip/vendor-index.xml","/CP065957_VMw.zip/metadata.zip/vmware.xml","/CP065957_VMw.zip/metadata.zip/vibs/CP065957-1607623874845420466.xml","/CP065957_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065957_HPD8.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"9181fd91585914c8d615c847ed1191a6","Name":"CP065957.zip","Release":"2025-03-06T05:39:47","Revision":"C","SHA1Sum":"ad98f982776e3c603f88c12a73b80dc3d16a7c51","SHA256Sum":"42f70bab19b837073efad03725fb725e210fe89b3a0cdc893442a510ac9ec3b1","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP065957","Version":"HPD8.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041554.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO007680RWUFC","TargetGUID":"562340a5-304f-3730-3638-305257554643","Type":"sas"},{"Id":"VO003840RWUFF","TargetGUID":"562340a5-304f-3330-3834-305257554646","Type":"sas"},{"Id":"VO003840RWUFB","TargetGUID":"562340a5-304f-3330-3834-305257554642","Type":"sas"},{"Id":"VO001920RWUFE","TargetGUID":"562340a5-304f-3130-3932-305257554645","Type":"sas"},{"Id":"VO001920RWUFA","TargetGUID":"562340a5-304f-3130-3932-305257554641","Type":"sas"},{"Id":"VO000960RWUFD","TargetGUID":"562340a5-304f-3030-3936-305257554644","Type":"sas"},{"Id":"VO000960RWUEV","TargetGUID":"562340a5-304f-3030-3936-305257554556","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:43:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8fe40c9bdbd145d3bc4d739f464f1c54"}]},{"ProductId":"dea19449209743ffa1d2262e07eafb25","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U33_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11583013","DateModified":"2026-01-11T22:18:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.62_2026_01_09-1.1/CP070242.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.62_2026_01_09-1.1/U33_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070242.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070242.scexe"],"MD5Sum":"732356bd9292c87129db0b1eac10f191","Name":"firmware-system-u33-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-12T04:09:27","Revision":"","SHA1Sum":"7870d4b6f47cf18f8e59294721ee51c4f90c36e8","SHA256Sum":"fbed550cb93d20e41bc37931521209c526e5ed251b6af577d54c3762f263b679","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上に見られるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen10 (U33) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML110 Gen10 (U33)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen10 (U33) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T04:08:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"53e91569dc6144d096a30afa1e2949d1"}]},{"ProductId":"824707fd6d4844feaef370452b0a3a3e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U44_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.72 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9043939","DateModified":"2026-01-13T02:23:30","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.72_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.72_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.72_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.72_2026_01_09-1.1/CP070192.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.72_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.72_2026_01_09-1.1/U44_3.72_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.72_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.72_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.72_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070192.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070192.scexe"],"MD5Sum":"c3bbf8f32e0fed4c6210c52d92c3c7d9","Name":"firmware-system-u44-3.72_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T08:16:07","Revision":"","SHA1Sum":"8ccb8d50fe121e052a955ed5b400996a33526942","SHA256Sum":"950ee7ca4e0daa98f80526453ff0e99d8eb17fc0125b32b94820154edb44565e","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.72_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"ja","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T09:36:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.103と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.70_08-08-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_01-09-2026"}],"SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f8380e9008f14be3bdc087fcab3f2bc6"}]},{"ProductId":"d04d5f721c2f4e7798db0b91a4b31687","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U56_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34072228","DateModified":"2026-01-11T21:45:42","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.54_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.54_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.54_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.54_2026_01_09-1.1/CP070229.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.54_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.54_2026_01_09-1.1/U56_2.54_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.54_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.54_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.54_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070229.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070229.scexe"],"MD5Sum":"86d2d86def350b88bcfa29a4335f3b89","Name":"firmware-system-u56-2.54_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-12T03:38:26","Revision":"","SHA1Sum":"eb8487790d8b09e7707a66c32bd61d6f6cae1394","SHA256Sum":"e5391f5f7a8fbf2227a8731b879dafdeae3338cdb42da1232dfcdd0af58236ba","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000239"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE DL110 Gen10 Plus Telco (U56) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE DL110 Gen10 Plus Telco（U56）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE DL110 Gen10 Plus Telco (U56) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:38:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Whitley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.802（2.50_07_24_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U56","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2964a3f83f234573bd7d3a911ea34f27"}]},{"ProductId":"000bfbde35e84381b78976b2c1748662","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作するIntel Ethernet NIC用のiavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1416152","DateModified":"2025-11-16T06:42:15","FileList":["cp069547.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"MD5Sum":"d277d911735c08d1597c654117625cc4","Name":"cp069547.exe","Release":"2025-11-16T06:28:56","Revision":"B","SHA1Sum":"65fa718ff94c6d215db5c5d0d7f6cf2ed380148d","SHA256Sum":"4248a2866fd7f33744436cee6536def3f7afa214e7c3d3c5a1378e6e5327b22a","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.17.63.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel iavf Driver for Windows Server 2022"},{"Lang":"ja","Value":"Intel iavfドライバーfor Windows Server 2022"},{"Lang":"cn","Value":"Intel iavf Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"}],"SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"778fddd39d4443aebd4b4aca654853c6"}]},{"ProductId":"6e2efe0e417448ccaa6cfbf61d773824","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4427200","DateModified":"2025-08-02T21:27:19","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-1.1/BCHPC17M.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-1.1/CP067377.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067377.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067377.scexe"],"MD5Sum":"ac44658dab953f36fb02486e67872d5e","Name":"firmware-hdd-5dcf26fa42_0HPD3-1.1_amd64.deb","Release":"2025-08-03T02:20:01","Revision":"","SHA1Sum":"c9c7d6fc1c7a34125970e5ee4f28f306287f9771","SHA256Sum":"67dff31aacb702f978e1c4ed907818ea82f972c34afa59741915e001d09336cc","Size":"4MB","TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP040329.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EO001600JWDKR","TargetGUID":"452340a5-304f-3130-3630-304a57444b52","Type":"sas"},{"Id":"MO001600JWDLA","TargetGUID":"4d2340a5-304f-3130-3630-304a57444c41","Type":"sas"},{"Id":"MO003200JWDLB","TargetGUID":"4d2340a5-304f-3330-3230-304a57444c42","Type":"sas"},{"Id":"EO000400JWDKP","TargetGUID":"452340a5-304f-3030-3430-304a57444b50","Type":"sas"},{"Id":"MO000400JWDKU","TargetGUID":"4d2340a5-304f-3030-3430-304a57444b55","Type":"sas"},{"Id":"EO000800JWDKQ","TargetGUID":"452340a5-304f-3030-3830-304a57444b51","Type":"sas"},{"Id":"MO000800JWDKV","TargetGUID":"4d2340a5-304f-3030-3830-304a57444b56","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:04:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7827731f43134612b48fb4feededfd7f"}]},{"ProductId":"4c108242693848129dadc44c03c82865","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"IEGen10Plus_1.0.0.22.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPS Innovation Engineファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8409359","DateModified":"2022-07-29T03:15:36","FileList":["IEGen10Plus_1.0.0.22.signed.bin","IEGen10Plus_1.0.0.22.xml","payload.json"],"MD5Sum":"65fee9d87a847901be74f8252583943b","Name":"IEGen10Plus_1.0.0.22.fwpkg","Release":"2022-07-29T03:11:54","Revision":"B","SHA1Sum":"e743961dc9a51f5b0e59a516726ea8ee82d791f1","SHA256Sum":"f4b0c7da665d0f2f3e76e22a49c010fac744ce1c04327f9462c3e9bb617fd2eb","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ -  HPE Gen10 Plus Innovation Engineファームウェアfor HPE Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2022-08-14T09:31:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>なし</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(B) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(B) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(B) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"}],"SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"5ba2fe62306d406aae00e2995213020e"}]},{"ProductId":"169b01f1c4c245bc854a8424af9a5f85","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.62 (01/09/2026)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11613528","DateModified":"2026-01-14T03:15:20","FileList":["cp070214.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U31_3.62_01_09_2026.signed.flash"],"MD5Sum":"27838644c1d001758454beee0a12fc01","Name":"cp070214.exe","Release":"2026-01-14T03:12:15","Revision":"","SHA1Sum":"3bca378a1e211967e3e366d7b4a8f84d85f0bdb7","SHA256Sum":"7cb356b9e7f1bcda64296cbb27668f9079a8ae0b7a77cf6a8448710898fdb4eb","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T02:23:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"a1be94b4e77745e5bc05bd971321ac2d"}]},{"ProductId":"12c818024cd141bdb20ae5471187f1ac","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2371240","DateModified":"2025-12-11T08:01:07","FileList":["./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-1.1/CP069040.xml","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-1.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-1.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-1.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069040.scexe","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069040.scexe"],"MD5Sum":"e1273d632883f00217d202f9edd83ca5","Name":"firmware-disk-enclosure_5.04-1.1_amd64.deb","Release":"2025-12-11T13:53:33","Revision":"A","SHA1Sum":"942766e710ec4fe57c4653c5ab2852634a79d6a5","SHA256Sum":"31ff672370e2980b7b7251180b4906278125800942488c9dbf4e054870312a76","Size":"2MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"Installation":{"Command":"setup","CommandParams":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp;&nbsp;<em>dpkg -i firmware-.....deb -f.&nbsp;</em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v266654/20-D3000-Gen10RN504M_ED13.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp;&nbsp;<em>dpkg -i firmware-.....deb -f.&nbsp;</em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v266654/20-D3000-Gen10RN504M_ED13.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp;&nbsp;<em>dpkg -i firmware-.....deb -f.&nbsp;</em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v266654/20-D3000-Gen10RN504M_ED13.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)"},{"Lang":"ja","Value":"HPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Ubuntu (x64)"},{"Lang":"cn","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3600","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Type":"sas"},{"Id":"D3610","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3700","TargetGUID":"b99dfb74-f0bc-464f-b418-cd186af467e1","Type":"sas"},{"Id":"D3710","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-06T07:30:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Ubuntu 22.04 LTS</p></li><li><p>Added support of&nbsp;Ubuntu 24.04 LTS.</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275184/20-D3000-Gen10RN504O_ED15.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Ubuntu 22.04LTSのサポートを追加しました</p></li><li><p>Ubuntu 24.04LTSのサポートを追加しました</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275184/20-D3000-Gen10RN504O_ED15.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Ubuntu 22.04 LTS</p></li><li><p>Added support of&nbsp;Ubuntu 24.04 LTS.</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275184/20-D3000-Gen10RN504O_ED15.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"}],"SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9b4e8f87360f40ff80ae35f17c185313"}]},{"ProductId":"b9b10cbec6a7489cae77c802c13728a1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB002000JYDNE and MB004000JYDPB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB002000JYDNEおよびMB004000JYDPB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB002000JYDNE and MB004000JYDPB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB002000JYDNE and MB004000JYDPB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"6374803","DateModified":"2025-09-17T12:09:17","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/CP068837.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/SCIMARBPNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068837.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068837.scexe"],"MD5Sum":"25e1e4d5f03bfab7f3115d6c151ffdd0","Name":"firmware-hdd-d4be2aecbb-HPD6-2.1.x86_64.rpm","Release":"2025-09-17T16:56:05","Revision":"B","SHA1Sum":"0fe891cd8ec3ab3541428f295dba8efe4ddcd890","SHA256Sum":"bb1d89ecdb98ff30bbb9d01d827d8ed627ac1434ca33b12f944e1f0586b33211","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB002000JYDNE and MB004000JYDPB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB002000JYDNEおよびMB004000JYDPBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JYDPB","TargetGUID":"4d2340a5-3042-3430-3030-304a59445042","Type":"sas"},{"Id":"MB002000JYDNE","TargetGUID":"4d2340a5-3042-3230-3030-304a59444e45","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T17:56:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c975c71029334580b2c010de2535eb50"}]},{"ProductId":"d7cf155e76584b1f8fb8e3c7c222c90d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB008000GWRTC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6276873","DateModified":"2025-09-17T11:39:37","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/CP068847.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/HVLPeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068847.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068847.scexe"],"MD5Sum":"5632b45feb96b6290ace2bd902845c84","Name":"firmware-hdd-82894b9e0a-HPG1-14.1.x86_64.rpm","Release":"2025-09-17T16:27:05","Revision":"N","SHA1Sum":"6ea357d1e942e6e735dc5f40925d67b6c3d94b6d","SHA256Sum":"69ea5e9f0ada52722cca3cade40bcf985f71b8fa6ad89c0c8ffe9e8f35c2d916","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP041482.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWRTC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000GWRTC ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000GWRTC","TargetGUID":"4d2340a5-3042-3830-3030-304757525443","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:19:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RHEL 10のサポートを追加しました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4f9966fcba4646cfb18939f7e10db7d5"}]},{"ProductId":"955cffa0d4fe4b76923c0ea7afeca0bf","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA4_FH_4p90_PLDMoMCTP_80020F02.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"4.90"}]},"MinimumActiveVersion":"4.20","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA4 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td><td>80020F02</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28アダプター</td><td>80020F02</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.9と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td><td>80020F02</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"}],"Files":[{"Bytes":"10526553","DateModified":"2025-12-18T07:23:22","FileList":["HPE_E810_XXVDA4_FH_4p90_PLDMoMCTP_80020F02.HPb","HPE_E810_XXVDA4_FH_4p90_PLDMoMCTP_80020F02.xml","payload.json"],"MD5Sum":"5539248d44418b1d567d53408b009a60","Name":"HPE_E810_XXVDA4_FH_4p90_PLDMoMCTP_80020F02.fwpkg","Release":"2025-12-18T07:20:06","Revision":"B","SHA1Sum":"b0940743c60b183ed589b759f81b10b44b7c92c8","SHA256Sum":"708fc087619d7f07f567f6d2e43f1c56b4b61e73142ba0ce6f916aec611596fa","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159380860005"],"TypeOfChange":"1","Version":"4.90"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-18T06:15:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"},{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"}],"SWKeys":[{"Name":"INTEL_E810_XXV4_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"f89af3c7e94d48c4ad6a028e8aecd58d"}]},{"ProductId":"4bdcb7d3fc5c4d14af793003b89e365b","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U45_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33611058","DateModified":"2026-01-14T06:36:18","FileList":["payload.json","U45_3.62_01_09_2026.signed.flash","U45_3.62_01_09_2026.xml"],"MD5Sum":"f1ff7adfc2e0f68bf9fc29146c59d352","Name":"U45_3.62_01_09_2026.fwpkg","Release":"2026-01-14T06:32:23","Revision":"","SHA1Sum":"0c754dbc5a231fad7e40f5ce95eb96101d8ae90f","SHA256Sum":"e3436d3ae5fa10239334478737d0bbc64d8971d3d246b0a93fce96507aa9bd0b","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:50:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"7229044bddab498fab907fd3e4eb99f7"}]},{"ProductId":"84d998355c4f4bc6997437e9a6c61fba","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp067949.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.201"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3344393","DateModified":"2025-08-04T04:08:38","FileList":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/CP067951.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/cp067949.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/cp067949.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067951.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067951.scexe"],"MD5Sum":"92e7a0274e0c854ff34d84102ee7b018","Name":"firmware-spsgen10-04.01.05.201-1.1.x86_64.rpm","Release":"2025-08-04T09:01:18","Revision":"","SHA1Sum":"094933687b39304900d9722d5945edbac24bd421","SHA256Sum":"84bff5ff25574ab560e86045e167da0d2136ba891b7d12afcbe08c907884d9d0","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.201"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","DeviceGUID":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","SWKey":"IE-Gen10","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"0.1.4.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOでサポートされていないEdgelineブレードを除き、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-28T07:17:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.01.05.105は、システムROM 3.40 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.01.05.105"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"04.01.05.201"}],"SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b543bb6e4f5c49269fa389331223bc64"}]},{"ProductId":"ab6756bde612475998d62d4bbb8717ff","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、VO015360KYDNB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version&nbsp;HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version&nbsp;to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version&nbsp;HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version&nbsp;to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5487472","DateModified":"2025-11-17T08:41:21","FileList":["cp068641.xml","cpqsetup.exe","GPM173XAHPK6.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"0173cfe6567c4670a21f31b46a624665","Name":"cp068641.exe","Release":"2025-11-17T08:36:06","Revision":"C","SHA1Sum":"b0bb64448539df7575860edd075a005ac073f70d","SHA256Sum":"349ffe2cf282ec59c44ce0fcaf4d08087791ba0a51622fefe7b76dd7ed594836","Size":"5MB","TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MO001600KYDMU","TargetGUID":"4d2340a5-304f-3130-3630-304b59444d55","Type":"nvme"},{"Id":"MO006400KYDND","TargetGUID":"4d2340a5-304f-3630-3430-304b59444e44","Type":"nvme"},{"Id":"VO015360KYDNB","TargetGUID":"562340a5-304f-3531-3336-304b59444e42","Type":"nvme"},{"Id":"VO007680KYDNA","TargetGUID":"562340a5-304f-3730-3638-304b59444e41","Type":"nvme"},{"Id":"MO003200KYDNC","TargetGUID":"4d2340a5-304f-3330-3230-304b59444e43","Type":"nvme"},{"Id":"VO001920KYDMT","TargetGUID":"562340a5-304f-3130-3932-304b59444d54","Type":"nvme"},{"Id":"VO003840KYDMV","TargetGUID":"562340a5-304f-3330-3834-304b59444d56","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:08:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK6"}],"SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"244a6149e7704ded8c87c64b7bae5bbe"}]},{"ProductId":"6792e601e784404b8b27e1297a68223e","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3438-3047584e5842","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3936-3047584e5a4b","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3936-3053584e5843","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3130-3932-3047584e5a4c","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3130-3932-3053584e5a50","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3330-3834-3047584e5a4e","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3234-3047584e5755","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3438-3047584e5a41","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3438-3053584e5756","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3936-3047584e5a42","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-3047584e5a43","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-3053584e5a46","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3330-3834-3047584e5a44","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3730-3638-3047584e5a45","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3234-3047584e5841","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-3047584e5a48","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MK000480GXNXB, MK000960GXNZK, MK001920GXNZL, MK003840GXNZN, VK000240GXNWU, VK000480GXNZA, VK000960GXNZB, VK001920GXNZC, VK003840GXNZD, VK007680GXNZE, VK000480SXNWV, VK001920SXNZF, MK000960SXNXC, MK001920SXNZP, VR000240GXNXA and VR000480GXNZH"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MK000480GXNXB, MK000960GXNZK, MK001920GXNZL, MK003840GXNZN, VK000240GXNWU, VK000480GXNZA, VK000960GXNZB, VK001920GXNZC, VK003840GXNZD, VK007680GXNZE, VK000480SXNWV, VK001920SXNZF, MK000960SXNXC, MK001920SXNZP, VR000240GXNXA and VR000480GXNZH"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MK000480GXNXB, MK000960GXNZK, MK001920GXNZL, MK003840GXNZN, VK000240GXNWU, VK000480GXNZA, VK000960GXNZB, VK001920GXNZC, VK003840GXNZD, VK007680GXNZE, VK000480SXNWV, VK001920SXNZF, MK000960SXNXC, MK001920SXNZP, VR000240GXNXA and VR000480GXNZH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>Improve FW handling on capacitor charge timeout mechanism</li><li>Change the sense code during download microcode (0E).</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>Improve FW handling on capacitor charge timeout mechanism</li><li>Change the sense code during download microcode (0E).</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>Improve FW handling on capacitor charge timeout mechanism</li><li>Change the sense code during download microcode (0E).</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4927139","DateModified":"2025-06-12T05:16:16","FileList":["Micron_5400_M5400ALLHPG1.HPb","Micron_5400_M5400ALLHPG1.xml","payload.json"],"MD5Sum":"ade5b00a5e5f8a33d482a7a52ad7386c","Name":"Micron_5400_M5400ALLHPG1.fwpkg","Release":"2025-06-12T05:13:39","Revision":"","SHA1Sum":"27aee03c83eca71eef5cec16d5fa21b6125d949c","SHA256Sum":"8983bfd85cf5d061b13ae383f81c8907a90f1a737b7910ff88e0f255ba4cbb4c","Size":"4MB","TargetGUIDs":["4d2340a5-304b-3030-3438-3047584e5842","4d2340a5-304b-3030-3936-3047584e5a4b","4d2340a5-304b-3030-3936-3053584e5843","4d2340a5-304b-3130-3932-3047584e5a4c","4d2340a5-304b-3130-3932-3053584e5a50","4d2340a5-304b-3330-3834-3047584e5a4e","562340a5-304b-3030-3234-3047584e5755","562340a5-304b-3030-3438-3047584e5a41","562340a5-304b-3030-3438-3053584e5756","562340a5-304b-3030-3936-3047584e5a42","562340a5-304b-3130-3932-3047584e5a43","562340a5-304b-3130-3932-3053584e5a46","562340a5-304b-3330-3834-3047584e5a44","562340a5-304b-3730-3638-3047584e5a45","562340a5-3052-3030-3234-3047584e5841","562340a5-3052-3030-3438-3047584e5a48"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MK000480GXNXB, MK000960GXNZK, MK001920GXNZL, MK003840GXNZN, VK000240GXNWU, VK000480GXNZA, VK000960GXNZB, VK001920GXNZC, VK003840GXNZD, VK007680GXNZE, VK000480SXNWV, VK001920SXNZF, MK000960SXNXC and MK001920SXNZP"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MK000480GXNXB, MK000960GXNZK, MK001920GXNZL, MK003840GXNZN, VK000240GXNWU, VK000480GXNZA, VK000960GXNZB, VK001920GXNZC, VK003840GXNZD, VK007680GXNZE, VK000480SXNWV, VK001920SXNZF, MK000960SXNXC and MK001920SXNZP"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MK000480GXNXB, MK000960GXNZK, MK001920GXNZL, MK003840GXNZN, VK000240GXNWU, VK000480GXNZA, VK000960GXNZB, VK001920GXNZC, VK003840GXNZD, VK007680GXNZE, VK000480SXNWV, VK001920SXNZF, MK000960SXNXC and MK001920SXNZP"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MK000480GXNXB","TargetGUID":"4d2340a5-304b-3030-3438-3047584e5842","Type":"sata"},{"Id":"MK000960GXNZK","TargetGUID":"4d2340a5-304b-3030-3936-3047584e5a4b","Type":"sata"},{"Id":"MK001920GXNZL","TargetGUID":"4d2340a5-304b-3130-3932-3047584e5a4c","Type":"nvme"},{"Id":"MK003840GXNZN","TargetGUID":"4d2340a5-304b-3330-3834-3047584e5a4e","Type":"sata"},{"Id":"VK000240GXNWU","TargetGUID":"562340a5-304b-3030-3234-3047584e5755","Type":"sata"},{"Id":"VK000480GXNZA","TargetGUID":"562340a5-304b-3030-3438-3047584e5a41","Type":"sata"},{"Id":"VK000960GXNZB","TargetGUID":"562340a5-304b-3030-3936-3047584e5a42","Type":"sata"},{"Id":"VK001920GXNZC","TargetGUID":"562340a5-304b-3130-3932-3047584e5a43","Type":"sata"},{"Id":"VK003840GXNZD","TargetGUID":"562340a5-304b-3330-3834-3047584e5a44","Type":"sata"},{"Id":"MK000960SXNXC","TargetGUID":"4d2340a5-304b-3030-3936-3053584e5843","Type":"sata"},{"Id":"MK001920SXNZP","TargetGUID":"4d2340a5-304b-3130-3932-3053584e5a50","Type":"sata"},{"Id":"VK001920SXNZF","TargetGUID":"562340a5-304b-3130-3932-3053584e5a46","Type":"sata"},{"Id":"VK000480SXNWV","TargetGUID":"562340a5-304b-3030-3438-3053584e5756","Type":"sata"},{"Id":"VK007680GXNZE","TargetGUID":"562340a5-304b-3730-3638-3047584e5a45","Type":"sata"},{"Id":"VR000240GXNXA","TargetGUID":"562340a5-3052-3030-3234-3047584e5841","Type":"sata"},{"Id":"VR000480GXNZH","TargetGUID":"562340a5-3052-3030-3438-3047584e5a48","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-04T03:04:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This is initial release</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>最初のリリースです</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This is initial release</p>","Lang":"cn"}],"Version":"HPG0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improve FW handling on capacitor charge timeout mechanism</li><li>Change the sense code during download microcode (0E)</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Improve FW handling on capacitor charge timeout mechanism</li><li>Change the sense code during download microcode (0E)</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improve FW handling on capacitor charge timeout mechanism</li><li>Change the sense code during download microcode (0E)</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MK000480GXNXB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GXNZK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GXNZL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GXNZN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GXNWU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GXNZA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GXNZB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GXNZC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GXNZD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GXNZE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480SXNWV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920SXNZF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960SXNXC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920SXNZP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VR000240GXNXA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VR000480GXNZH","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"02859ac29430461593ee92cdbde4dc9b"}]},{"ProductId":"3d28404b009047cd9c6ade47efd24ca6","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41598","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41598","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41598","Version":"235.1.164.14"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57504 OCP Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57504 OCP Gigabit Ethernet NIC firmware."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57504 OCP Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 235.1.164.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.6<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 235.1.164.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.6<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 235.1.164.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.6<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"2802434","DateModified":"2025-12-11T09:40:15","FileList":["BCM235.1.164.14_BCM957504-N425H.HPb","BCM235.1.164.14_BCM957504-N425H.xml","payload.json"],"MD5Sum":"6dd42c4a0145e6b2d60c084b340576e9","Name":"BCM235.1.164.14_BCM957504-N425H.fwpkg","Release":"2025-12-11T09:36:31","Revision":"","SHA1Sum":"a7a17e2b27782533cfef53a41c0327d9da2a01a6","SHA256Sum":"2d64ce55fdf7451af254984a78c2bd458d19b87563bcea7d31bc720b9141b7de","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41598"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-11T07:48:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"BCM_NXE_57504OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"5adaba69e9b54483b04e405655ff608f"}]},{"ProductId":"5b5ee0e363994b83af6394dce2b49314","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.00"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.00"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.00"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.00"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.00"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.00"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"この x64 Smartコンポーネントは、次のストレージコントローラー用のファームウェアを提供します。 HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10 コントローラー"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;7.81<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />     オンラインROMフラッシュコンポーネントfor Ubuntu - HPE SmartアレイP408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10コントローラー</p><p> </p><p><strong>リリースバージョンおよび/または日付：</strong><br />     7.81<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     NA<br /><br /><strong>前のファームウェアバージョン：</strong><br />     NA<br /><br /><strong>ファームウェアの依存関係:</strong></p><p>    なし<br /><br /><strong>機能強化/新しい機能：</strong></p><p>    なし</p><p> </p><p><strong> 修正された問題点：</strong></p><p>     なし</p><p> </p><p><strong>既知の問題点：</strong><br />     なし</p><p> </p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;7.81<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"7784572","DateModified":"2025-12-04T00:34:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-8.00-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-8.00-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-8.00-1.1/CP069170.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-8.00-1.1/HPE_luxor_8.00.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-8.00-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-8.00-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-8.00-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069170.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-8.00-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069170.scexe"],"MD5Sum":"09a96830bfde463038dd274c65e03566","Name":"firmware-smartarray-98373e8f27_8.00-1.1_amd64.deb","Release":"2026-02-02T00:00:00","Revision":"","SHA1Sum":"267713df8e07605bd05d2d75ae37ec408ec42b2a","SHA256Sum":"f3656db1e57577834704954160d5c387d67613cb68940f31e5384a0ab76755ad","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.00"}],"Installation":{"Command":"CP069170.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Ubuntu&nbsp;operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp; </em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のUbuntuオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p> </p><p><strong><em>debをインストールしてファームウェアをアップデートする:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>次のコマンドを使用してファームウェアのdebをインストールします: sudo dpkg -i<em><deb_ファイル名>。  </em>これは、'/usr/lib/x86_64-linux-gnu'へdebの内容を抽出します</li><li>CPXXXXXX.scexeスクリプトは、'scexe-compat'フォルダーにあります。 'firmware-smartarray-xxxxxxxxxx-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるdebのバージョンに基づきます</li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>./CPXXXXXX.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li><li><em>./setup</em>（'/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*'内）</li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>debをアンインストールするには、次のコマンドを実行します: sudo dpkg -P<em><deb_パッケージ名></em>（これは「.deb」拡張子のないdebファイル名です）</li></ul><p><strong><em>追加情報：</em></strong></p><p>ファームウェアdebパッケージのインストール (sudo dpkg -i) は、ファームウェアをアップデートしません。  単に、ローカルシステムへのdebの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p> </p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li><li>ISOのルートにある launch_sum.sh スクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Ubuntu&nbsp;operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp; </em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Ubuntu - HPE SmartアレイP408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10コントローラー"},{"Lang":"cn","Value":"Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2026-03-03T07:48:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"cn"}],"Version":"8.00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"cn"}],"Version":"8.00"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2c9a46f86d4b4eea8739911693777d2f"}]},{"ProductId":"ffc5db5b28504df99cd08b4bf08ccc7d","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp067949.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.201"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3793128","DateModified":"2025-11-14T02:46:18","FileList":["cp067949.compsig","cp067949.zip","cp069580.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"cc50c39ab71fff77dbfd2f58b15c0f5d","Name":"cp069580.exe","Release":"2025-11-14T02:43:46","Revision":"B","SHA1Sum":"a86c698d10c506d7af5835b1b2d9f90e36aa605d","SHA256Sum":"ee0a13e771050c3209a72b24337e2a8d4710f55565c3a83c5848fdecf53f78fd","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.201"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","DeviceGUID":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","SWKey":"IE-Gen10","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"0.1.4.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOでサポートされていないEdgelineブレードを除き、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE Gen10サーバー向けServer Platform Services(SPS)ファームウェア"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T02:25:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 04.01.05.201 should be paired with System ROM 3.60 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.01.05.201は、システムROM 3.60 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 04.01.05.201 should be paired with System ROM 3.60 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.01.05.201"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 04.01.05.201 should be paired with System ROM 3.60 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.01.05.201は、システムROM 3.60 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 04.01.05.201 should be paired with System ROM 3.60 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.01.05.201"}],"SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c974efff3c5945fb8a834885625f2b03"}]},{"ProductId":"3702e2a6624243b4a85fa9ca1f4c0ce2","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A48_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34235408","DateModified":"2026-01-13T06:30:58","FileList":["A48_4.00_01_09_2026.signed.flash","cp070366.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"4a9856347d2ff9fb13ac7bfac17a2abb","Name":"cp070366.exe","Release":"2026-01-13T06:28:37","Revision":"","SHA1Sum":"2694ae110a9cc5cbcd3cbaddeac22575aab99054","SHA256Sum":"01132106ffa6936d6730983cb69640f1365e48385328922bc719648fa587db8e","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T06:28:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.90_10-03-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"9ab6d5db1c064de98baa332c8c5159a1"}]},{"ProductId":"7e0050d7cc724a879a45bb605213e3c8","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE90X0_KPE9010SHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3936-305959585052","Version":"HPK2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VR000960YYXPR"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: VR000960YYXPR"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VR000960YYXPR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1991848","DateModified":"2025-06-13T05:27:15","FileList":["payload.json","SKHynix_PE90X0_KPE9010SHPK2.HPb","SKHynix_PE90X0_KPE9010SHPK2.xml"],"MD5Sum":"5cc3c0fa83cf5903efeef60259d21566","Name":"SKHynix_PE90X0_KPE9010SHPK2.fwpkg","Release":"2025-06-13T05:25:10","Revision":"","SHA1Sum":"ebb12d8ca3ec4e2e8635eeb5cc70c219a8fe9e22","SHA256Sum":"a3b3bb908312a707ab1abcf9b1bcbd8786d20ec150d0e494d2bd064a6e5175bc","Size":"1MB","TargetGUIDs":["562340a5-3052-3030-3936-305959585052"],"TypeOfChange":"1","Version":"HPK2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  VR000960YYXPR"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  VR000960YYXPR"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  VR000960YYXPR"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VR000960YYXPR","TargetGUID":"562340a5-3052-3030-3936-305959585052","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-13T03:49:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>RSOD issue fixed. RSOD was occurred during server power-on if enable the VROC.</li></ul>","Lang":"cn"}],"Version":"HPK2"}],"SWKeys":[{"Name":"VR000960YYXPR","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"4924d8e0104a4e96a2206473e4ce8b62"}]},{"ProductId":"8085229a62d8443d85751340431d38d5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.624.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"ja","Value":"HPE Storageファイバーチャネル（FC）アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター（HBA）ドライバーを提供する、バージョン14.4.624.0 のEmulex Storportドライバーfor Extended Systemが含まれています。"},{"Lang":"cn","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.624.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4293392","DateModified":"2025-11-24T08:52:16","FileList":["cp066304.xml","cpqsetup.exe","elxdrvr-fc-14.4.624.0-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"MD5Sum":"82613db8dc2f6dc753c38d6eb9262409","Name":"cp066304.exe","Release":"2025-11-24T08:50:34","Revision":"","SHA1Sum":"33c2a605c0f587f0d3c4fd65b2fcc7160b43f371","SHA256Sum":"fec94f608f5e185c8827e317abb8e31f20dc483abee39dd1aa6b294e89006dae","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.624.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p> </p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2022"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T12:12:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.393.20にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.393.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.624.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.624.0にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>    elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.624.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.624.0"}],"SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"19d55aa412b443249ba2db4f499373a0"}]},{"ProductId":"251bfe38793342929fa427f7b456f043","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2353212","DateModified":"2025-12-11T09:05:30","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-1.1/CP069047.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-1.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-1.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-1.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069047.scexe","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069047.scexe"],"MD5Sum":"98b501192633410c6002ebc708da5aba","Name":"firmware-d6020_2.74-1.1_amd64.deb","Release":"2025-12-11T14:57:30","Revision":"A","SHA1Sum":"ec43cb46a92a18bf68ab5bb52b628fa875766c68","SHA256Sum":"6cd02af593a0dd4d1117c370d75c709d76700b2a1d9ed9262192a1c8b510dbb7","Size":"2MB","TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"Installation":{"Command":"setup","CommandParams":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp; <em>dpkg -i firmware-.....deb -f. </em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # <em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e,&nbsp;--reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f,&nbsp; --force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g,&nbsp;--downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s,&nbsp;--silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp; <em>dpkg -i firmware-.....deb -f. </em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # <em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e,&nbsp;--reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f,&nbsp; --force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g,&nbsp;--downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s,&nbsp;--silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with deb installation:</strong>&nbsp;</p><ul><li>Install the firmware deb&nbsp;using the command:&nbsp; <em>dpkg -i firmware-.....deb -f. </em>This extracts the contents of the deb&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.&nbsp;</li><li>The CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the deb&nbsp;installed in the first step above.&nbsp;</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:&nbsp;&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)&nbsp;</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # <em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location&nbsp;</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.&nbsp;</li><li>To uninstall the deb, run the command: apt remove firmware-d3000, which is the deb filename without the &#39;.deb&#39; extension.&nbsp;</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e,&nbsp;--reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f,&nbsp; --force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g,&nbsp;--downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s,&nbsp;--silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)"},{"Lang":"ja","Value":"HPE D6020 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Ubuntu (x64)"},{"Lang":"cn","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D6020","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-06T08:15:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Ubuntu 22.04 LTS</p></li><li><p>Added support of&nbsp;Ubuntu 24.04 LTS.</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Ubuntu 22.04LTSのサポートを追加しました</p></li><li><p>Ubuntu 24.04LTSのサポートを追加しました</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Ubuntu 22.04 LTS</p></li><li><p>Added support of&nbsp;Ubuntu 24.04 LTS.</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"}],"SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bf61ca3df1ff44339d6a98ee4135df75"}]},{"ProductId":"17cb0fd9f2dc47bb8aba197c6f346c61","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 661SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./XXV710DA2_8p30_CFGID12p0_OEMGEN_J65979.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-158b15900253","Version":"8.30"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline System running a supported Linux Operating System installed in HPE Edgeline EL8000/EL8000t chassis."},{"Lang":"ja","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline System running a supported Linux Operating System installed in HPE Edgeline EL8000/EL8000t chassis."},{"Lang":"cn","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline System running a supported Linux Operating System installed in HPE Edgeline EL8000/EL8000t chassis."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9916654","DateModified":"2026-01-23T09:27:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/661SFP.cfg","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/CP057532.xml","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/FVL_25G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/XXV710DA2_9p20_CFGID12p0_OEMGEN.bin","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/iSCSI.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/iv.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/nvmupdatew64e","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/payload_version.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP057532.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP057532.scexe"],"MD5Sum":"2a7e26a2c2ac0cf538b19bda0d9d5f80","Name":"firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1.x86_64.rpm","Release":"2026-01-23T15:11:50","Revision":"","SHA1Sum":"f8aa8f0cea397d0e855b5c95dbd5f65d7b325ee7","SHA256Sum":"affa7d46593a19de265339be4059663321283ff2bac1737196a117f58e911211","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-158b15900253"],"TypeOfChange":"1","Version":"9.20"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To install firmware from Linux operating system on target server:</strong></p><p>&nbsp;</p><p>Execute the below commands:</p><p>&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change(cd) to the directory you see in the previous step and run hpsetup by typing &lsquo;./setup&rsquo; at the command prompt.</p><p><strong>Note</strong>: Installing the firmware rpm package (rpm -ivh) does not update the firmware. &nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed using SUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"},{"Lang":"ja","Value":"<p><strong>To install firmware from Linux operating system on target server:</strong></p><p>&nbsp;</p><p>Execute the below commands:</p><p>&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change(cd) to the directory you see in the previous step and run hpsetup by typing &lsquo;./setup&rsquo; at the command prompt.</p><p><strong>Note</strong>: Installing the firmware rpm package (rpm -ivh) does not update the firmware. &nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed using SUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"},{"Lang":"cn","Value":"<p><strong>To install firmware from Linux operating system on target server:</strong></p><p>&nbsp;</p><p>Execute the below commands:</p><p>&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change(cd) to the directory you see in the previous step and run hpsetup by typing &lsquo;./setup&rsquo; at the command prompt.</p><p><strong>Note</strong>: Installing the firmware rpm package (rpm -ivh) does not update the firmware. &nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed using SUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Edgeline 661SFP28 NIC Firmware Pack for Linux"},{"Lang":"ja","Value":"HPE Edgeline 661SFP28 NIC Firmware Pack for Linux"},{"Lang":"cn","Value":"HPE Edgeline 661SFP28 NIC Firmware Pack for Linux"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"158B","SubDev":"0253","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-158b15900253","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"20","Minor":"4","Name":"Ubuntu 20.04 LTS","Platform":"ubuntu","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-07-12T19:25:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Resolves an issue where, with very low probability, PCIe access conflicts can result in a system hang. A signature of this failure may be found in BMC or BIOS error logs showing CPU IERR and/or CATERR reports</p>","Fixes":"<p>Latest FW Version 9.20</p>","Lang":"en"},{"Enhancements":"<p>Resolves an issue where, with very low probability, PCIe access conflicts can result in a system hang. A signature of this failure may be found in BMC or BIOS error logs showing CPU IERR and/or CATERR reports</p>","Fixes":"<p>Latest FW Version 9.20</p>","Lang":"ja"},{"Enhancements":"<p>Resolves an issue where, with very low probability, PCIe access conflicts can result in a system hang. A signature of this failure may be found in BMC or BIOS error logs showing CPU IERR and/or CATERR reports</p>","Fixes":"<p>Latest FW Version 9.20</p>","Lang":"cn"}],"Version":"9.20"}],"SWKeys":[{"Name":"XXV710_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"467ada0499c54be9b337386ee64ba5b4"}]},{"ProductId":"f7d7f54393d44f66845199e26d4e5900","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPK および EH000600JWHPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPK and EH000600JWHPH Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPK and EH000600JWHPH Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"18068581","DateModified":"2025-06-14T08:31:00","FileList":["/CP067532_BUILD_2.data","/CP067532.vmexe64","/CP067532.vmfile","/CP067532_VMw.zip","/CP067532.xml","/payload.json","/CP067532_VMw.zip/index.xml","/CP067532_VMw.zip/vendor-index.xml","/CP067532_VMw.zip/metadata.zip","/CP067532_VMw.zip/vib20/CP067532/HPE_bootbank_CP067532_HPD9.2-8.0.0.20613240.vib","/CP067532_VMw.zip/metadata.zip/vendor-index.xml","/CP067532_VMw.zip/metadata.zip/vmware.xml","/CP067532_VMw.zip/metadata.zip/vibs/CP067532--5424592729178971741.xml","/CP067532_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067532_HPD9.2-8.0.0.20613240.xml"],"MD5Sum":"d37cf76ec04a5c8a2b41d2b198573388","Name":"CP067532.zip","Release":"2025-06-14T08:30:07","Revision":"C","SHA1Sum":"feb1259637d1905352cc9d2c7a3ff66529489808","SHA256Sum":"17e7ff850f26fe26228374da65413d055700a27e113dbd98ab09870b9edf6994","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP067532","Version":"HPD9.2-8.0.0.20613240"}]}],"Installation":{"Command":"CP042550.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPK and EH000600JWHPH   Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EH000900JWHPK","TargetGUID":"452340a5-3048-3030-3930-304a5748504b","Type":"sas"},{"Id":"EH000600JWHPH","TargetGUID":"452340a5-3048-3030-3630-304a57485048","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-10T19:30:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7adc9cc7a77a4a5e9b5f8a78c7be6f34"}]},{"ProductId":"8d934ba033f1419491e76cc92dd89795","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 10で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 10."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"552265","DateModified":"2025-09-15T15:52:29","FileList":["./etc/depmod.d/kmod-i40e.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/i40e/i40e.ko","./usr/share/doc/kmod-i40e","./usr/share/doc/kmod-i40e/COPYING","./usr/share/doc/kmod-i40e/README","./usr/share/doc/kmod-i40e/pci.updates","./usr/share/man/man7/i40e.7.gz","./usr/share/smartupdate/kmod-i40e/component.xml"],"MD5Sum":"825b337f403bcc440d111869582fc921","Name":"kmod-i40e-2.28.10-1.rhel10u0.x86_64.rpm","Release":"2025-09-15T15:47:16","Revision":"","SHA1Sum":"e498e522329c4b9542a215a14f9b9cfbe6ce9a22","SHA256Sum":"eceee90667415e29d5d1d9afef428c09276a90dbf77c5bb23459bac804a00267","Size":"539KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec805649d9"],"TypeOfChange":"1","Version":"2.28.10-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 10"},{"Lang":"ja","Value":"HPE Intel i40eドライバーfor Red Hat Enterprise Linux 10"},{"Lang":"cn","Value":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T01:43:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Red Hat Enterprise Server 10をサポートするための初回リリースです。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"cn"}],"Version":"2.28.7-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.28.10-1"}],"SWKeys":[{"Name":"kmod-i40e","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d7a7462c5a834d379eaf5c5dc51cbacd"}]},{"ProductId":"74ae203907f144b792d71fd805a36304","Versions":[{"DeviceClass":"42fc70be-bb87-4bdb-8e7c-db1c9af52957","Devices":{"Device":[{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.0.0s.bin","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000242","Version":"2.0.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.0.0s.bin","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"2.0.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.0.0s.bin","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000221","Version":"2.0.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Management"},{"Lang":"ja","Value":"ファームウェア - マネジメント"},{"Lang":"cn","Value":"固件 - 管理"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"545509","DateModified":"2025-10-07T14:42:12","FileList":["ACCE_2.0.0s.bin","ACCE_2.0.0s.xml","payload.json"],"MD5Sum":"a4f23a54de258ba39264d71a4db49456","Name":"ACCE_2.0.0s.fwpkg","Release":"2025-10-07T14:40:04","Revision":"B","SHA1Sum":"a4e511c85559d25bd5bdc40bffdd3335f286834f","SHA256Sum":"a485250b46b4e1360bf3e568baa161385a99e6b7feb0c5933fd95169cea6516d","Size":"532KB","TargetGUIDs":["00000000-0000-0000-0000-000000000242","00000000-0000-0000-0000-00000000023a","00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"2.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM,&nbsp;which is found on the <strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong> (SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the <strong><u><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></u></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong>（SPP）ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><u><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></u></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM,&nbsp;which is found on the <strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong> (SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the <strong><u><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></u></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE Edgeline Chassis Controller Firmware"},{"Lang":"ja","Value":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE Edgelineシャーシコントローラーファームウェア"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE Edgeline Chassis Controller Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-03T15:44:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Allowed to update chassis controller firmware when iLO security mode is set to CNSA</p>","Fixes":"<ul><li>Allowed to update chassis controller firmware when iLO security mode is set to CNSA</li><li>Signed with SHA384</li></ul>","Lang":"en"},{"Enhancements":"<p>iLOセキュリティモードがCNSAに設定されている場合にシャーシコントローラファームウェアをアップデートできます。</p>","Fixes":"<ul><li>iLOセキュリティモードがCNSAに設定されている場合にシャーシコントローラーファームウェアをアップデートできます。</li><li>SHA384で署名</li></ul>","Lang":"ja"},{"Enhancements":"<p>Allowed to update chassis controller firmware when iLO security mode is set to CNSA</p>","Fixes":"<ul><li>Allowed to update chassis controller firmware when iLO security mode is set to CNSA</li><li>Signed with SHA384</li></ul>","Lang":"cn"}],"Version":"1.5.10"},{"ReleaseNotes":[{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for EL8000s</p>","Fixes":"","Lang":"cn"}],"Version":"2.0.0"}],"SWKeys":[{"Name":"ACCE","SWKeyExpectedPath":"firmware:sd:ACC"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"18f5df56c9374d078ab9c46ec4c9d7c4"}]},{"ProductId":"2b44e5307a9948769c51d6ac1f276915","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U41_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33612477","DateModified":"2026-01-12T06:47:51","FileList":["payload.json","U41_3.62_01_09_2026.signed.flash","U41_3.62_01_09_2026.xml"],"MD5Sum":"b699ff2652528b04f262ee898f74abaf","Name":"U41_3.62_01_09_2026.fwpkg","Release":"2026-01-12T06:45:17","Revision":"","SHA1Sum":"53194d20782082e3d61d33749eb6955e22688b12","SHA256Sum":"284d12ca748259e66c6b0a515dbeb19c64d461a239edb2b522e6404c7a33df94","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers "},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers "},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T06:27:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"b9f7911ef9fe42d099ee0e9a9c97c065"}]},{"ProductId":"5e23a12643374784bca02e8442853ff7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKLおよび、MB018000JYDKN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4355800","DateModified":"2025-11-16T14:28:16","FileList":["cp068738.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVSBPSD6.rel"],"MD5Sum":"82c88d59592e3d2a717771e28505d9db","Name":"cp068738.exe","Release":"2025-11-16T14:23:29","Revision":"B","SHA1Sum":"1b9e4ef5501f65f52d33cc3376e9d2e874304bbc","SHA256Sum":"30b46d016872244b191c192e397b9525ed6969054abbf8faece08d074cab1c2d","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKL、およびMB018000JYDKNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB010000JYDKK","TargetGUID":"4d2340a5-3042-3031-3030-304a59444b4b","Type":"sas"},{"Id":"MB012000JYCJF","TargetGUID":"4d2340a5-3042-3231-3030-304a59434a46","Type":"sas"},{"Id":"MB014000JYCJV","TargetGUID":"4d2340a5-3042-3431-3030-304a59434a56","Type":"sas"},{"Id":"MB016000JYDKL","TargetGUID":"4d2340a5-3042-3631-3030-304a59444b4c","Type":"sas"},{"Id":"MB018000JYDKN","TargetGUID":"4d2340a5-3042-3831-3030-304a59444b4e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T05:38:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブファームウェアが強化され、Primera 600 LFFエンクロージャー内の一部のバックアップドライブで予期しない電源喪失がまれに発生する可能性が低減しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul>","Lang":"cn"}],"Version":"HPD6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>ドライブファームウェアが強化され、Primera 600 LFFエンクロージャー内の一部のバックアップドライブで予期しない電源喪失がまれに発生する可能性が低減しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bb3daea065d04dc191baa120bf1a989a"}]},{"ProductId":"972a94402aa14188aa7633893c7137b6","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U33_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33612079","DateModified":"2026-01-12T04:06:17","FileList":["payload.json","U33_3.62_01_09_2026.signed.flash","U33_3.62_01_09_2026.xml"],"MD5Sum":"a5c24bc3fed45044fa328b4a9486f544","Name":"U33_3.62_01_09_2026.fwpkg","Release":"2026-01-12T04:03:07","Revision":"","SHA1Sum":"f04f05c48886f7913aeeb76d6808e6dfb658b3ab","SHA256Sum":"63c419d1651f66a68aaeda823c2113b898d0e2a95f11cce3105f329dc33f3739","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T04:02:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"19bef68d6a9e47208bd48261b3bd5e82"}]},{"ProductId":"667c48761fdd439199126de11a3666a8","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp067923.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2178567","DateModified":"2025-08-13T01:50:19","FileList":["./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/CP067926.xml","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/cp067923.compsig","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/cp067923.zip","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067926.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067926.scexe"],"MD5Sum":"f3ed14c40c94950f5a9833e685711420","Name":"firmware-microservergen10plussps-05.01.05.103-1.1.x86_64.rpm","Release":"2025-08-13T06:42:08","Revision":"","SHA1Sum":"26cf48d5ae15a4c4c325b0e0feceee1867f714a3","SHA256Sum":"41a547f0c668a9d627f010799cfd67c0a4c8bdca5e87ee2d6c7034eab4d31f20","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-24T02:22:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 05.01.05.005は、システムROM 3.50 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"},{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"05.01.05.103"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fd0baef48822461c917023c73eb03c27"}]},{"ProductId":"9955e8989d3a49ccb377a1c01a7b8a6c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6403803","DateModified":"2025-09-21T21:56:31","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/CP068927.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/SSKYBT512EDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068927.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068927.scexe"],"MD5Sum":"287b249e3f53c179943991a04a545874","Name":"firmware-hdd-b1c9eaf74c-HPDB-3.1.x86_64.rpm","Release":"2025-09-22T02:43:45","Revision":"C","SHA1Sum":"6afefcc2508d6b8b6d11f4c4fd8507b2d48a43f5","SHA256Sum":"78c72c76bcd1da4096a415e955e2e2550e96900ccfb86a0c79e847af37bf9d42","Size":"6MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"CP041696.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG001800JWJNR","TargetGUID":"452340a5-3047-3130-3830-304a574a4e52","Type":"sas"},{"Id":"EG002400JWJNT","TargetGUID":"452340a5-3047-3230-3430-304a574a4e54","Type":"sas"},{"Id":"EG002400MXJQT","TargetGUID":"452340a5-3047-3230-3430-304d584a5154","Type":"sas"},{"Id":"EG001800JXLWB","TargetGUID":"452340a5-3047-3130-3830-304a584c5742","Type":"sas"},{"Id":"EG002400JXLWC","TargetGUID":"452340a5-3047-3230-3430-304a584c5743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:09:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ファームウェアバージョンHPDBを修正し、供給の継続性のために最新のNAND世代との互換性を追加します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a2bbb424bfdf4cb1a0025efc3d083fc5"}]},{"ProductId":"001e7fbaf67f420ebcb746aae6b4aee2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />      オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ<br /><br /><strong>リリースバージョンおよび/または日付：</strong><br />      HPD5<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />      HPD4<br /><br /><strong>前のファームウェアバージョン：</strong><br />      HPD4<br /><br /><strong>ファームウェアの関連性：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：<br />      </strong>なし</p>"}],"Files":[{"Bytes":"18458926","DateModified":"2025-03-07T06:58:26","FileList":["/CP065943_BUILD_1.data","/CP065943.vmexe64","/CP065943.vmfile","/CP065943_VMw.zip","/CP065943.xml","/payload.json","/CP065943_VMw.zip/index.xml","/CP065943_VMw.zip/metadata.zip","/CP065943_VMw.zip/vendor-index.xml","/CP065943_VMw.zip/vib20/CP065943/HPE_bootbank_CP065943_HPD5.1-1OEM.900.0.24580437.vib","/CP065943_VMw.zip/metadata.zip/vendor-index.xml","/CP065943_VMw.zip/metadata.zip/vmware.xml","/CP065943_VMw.zip/metadata.zip/vibs/CP065943--8168030897915548776.xml","/CP065943_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065943_HPD5.1-1OEM.900.0.24580437.xml"],"MD5Sum":"0e127e4bb6a79b62339a4382c15fea01","Name":"CP065943.zip","Release":"2025-03-07T06:57:37","Revision":"C","SHA1Sum":"d9877083724fa72dfbcc2de53637b48694d3ecee","SHA256Sum":"d9104e809dc5c165946f213338a5350e30e328b6579efce26e87a2e02cbd0888","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP065943","Version":"HPD5.1-1OEM.900.0.24580437"}]}],"Installation":{"Command":"CP040556.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on 7.0/8.0/9,0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on 7.0/8.0/9,0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO006400JWZJT","TargetGUID":"562340a5-304f-3630-3430-304a575a4a54","Type":"sas"},{"Id":"VO003200JWZJR","TargetGUID":"562340a5-304f-3330-3230-304a575a4a52","Type":"sas"},{"Id":"VO001600JWZJQ","TargetGUID":"562340a5-304f-3130-3630-304a575a4a51","Type":"sas"},{"Id":"VO000800JWZJP","TargetGUID":"562340a5-304f-3030-3830-304a575a4a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:26:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"40e0ce11db3743dc8166e4a30a532fbc"}]},{"ProductId":"5aad4922b5f54198b1d9a8e400dcfdda","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built for SUSE LINUX Enterprise Server 15 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMを使用して、HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plus、およびMR416i-p、MR416i-o、MR216i-o、MR408i-o、MR216i-p、MR408i-p Gen11コントローラーを有効にする、64ビットSUSE Linux Enterprise Server 15用のビルド済みバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"865523","DateModified":"2025-04-25T05:15:13","FileList":["./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"MD5Sum":"eb4f544c5009694a7118c247e04c48d8","Name":"lsi-megaraid_sas-kmp-default-07.732.03.00_sles15sp5-1.x86_64.rpm","Release":"2025-06-26T00:00:00","Revision":"B","SHA1Sum":"5fc4b2ed98e85765f07b6e44ba943cffdbae08fd","SHA256Sum":"bc0bb2e2af74221d3e8ebf72ab0c859bf4ffe2bc0041fa3a87b95f5b80bf8ca5","Size":"845KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.732.03.00"},{"Bytes":"954358","DateModified":"2025-04-25T05:21:12","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"MD5Sum":"69f059e434fa7d0c6bc1ee8f33c8d913","Name":"lsi-megaraid_sas-kmp-default-07.732.03.00_sles15sp6-1.x86_64.rpm","Release":"2025-06-26T00:00:00","Revision":"B","SHA1Sum":"334a0009e89a261967ab6cc4c311bb89767f34b8","SHA256Sum":"f8eaacab591ec4f933bfcf0d6540df327ee5d957ccf50819d7a3b7fe12a3224d","Size":"931KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.732.03.00"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To install/upgrade the driver, type the following command:</p><p># rpm -Uvh&nbsp;--oldpackage --replacefiles --replacepkgs lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)&nbsp;&nbsp;</p><p>&nbsp;</p><p>If Installation attempted is failed with &ldquo;Failed Dependency&rdquo; Error below Arguments are used to re-try the Installation.</p><p># rpm&nbsp;-Uvh --oldpackage --reinstall lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)</p><p>&nbsp;</p><p>A REBOOT is required for your computer when the setup is complete.</p>"},{"Lang":"ja","Value":"<p>ドライバーをインストール/アップグレードするには、次のコマンドを入力します。</p><p># rpm -Uvh --oldpackage --replacefiles --replacepkgs lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm （X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）  </p><p> </p><p>試行したインストールが\"Failed Dependency\"エラーで失敗した場合、インストールの再試行には次の引数を使用します。</p><p># rpm -Uvh --oldpackage --reinstall lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm （X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）</p><p> </p><p>セットアップが完了したらコンピューターをリブートする必要があります。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 15"},{"Lang":"ja","Value":"HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plusおよびMR416i-p、MR416i-o、MR216i-o、 MR408i-o、MR216i-p、MR408i-p Gen11コントローラードライバーfor 64ビットSUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T18:46:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Verified the UNMAP command and confirmed that the Block Limits VPD page data is&nbsp;correct with the latest firmware.</li></ul>","Fixes":"<ul><li>Fix a potential mutex deadlock between reset and event handling thread. The issue may&nbsp;happen when there is heavy IO, device add/delete and SCSI rescan running in the same&nbsp;time.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>UNMAP コマンドを検証し、最新のファームウェアでブロック制限 VPD ページ データが正しいことを確認しました。</li></ul>","Fixes":"<ul><li>リセットとイベント処理スレッド間の潜在的なミューテックスデッドロックを修正しました。この問題は、大量の IO、デバイスの追加/削除、SCSI 再スキャンが同時に実行されている場合に発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Verified the UNMAP command and confirmed that the Block Limits VPD page data is&nbsp;correct with the latest firmware.</li></ul>","Fixes":"<ul><li>Fix a potential mutex deadlock between reset and event handling thread. The issue may&nbsp;happen when there is heavy IO, device add/delete and SCSI rescan running in the same&nbsp;time.</li></ul>","Lang":"cn"}],"Version":"07.732.03.00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Verified the UNMAP command and confirmed that the Block Limits VPD page data is&nbsp;correct with the latest firmware.</li></ul>","Fixes":"<ul><li>Fix a potential mutex deadlock between reset and event handling thread. The issue may&nbsp;happen when there is heavy IO, device add/delete and SCSI rescan running in the same&nbsp;time.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>UNMAP コマンドを検証し、最新のファームウェアでブロック制限 VPD ページ データが正しいことを確認しました。</li></ul>","Fixes":"<ul><li>リセットとイベント処理スレッド間の潜在的なミューテックスデッドロックを修正しました。この問題は、大量の IO、デバイスの追加/削除、SCSI 再スキャンが同時に実行されている場合に発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Verified the UNMAP command and confirmed that the Block Limits VPD page data is&nbsp;correct with the latest firmware.</li></ul>","Fixes":"<ul><li>Fix a potential mutex deadlock between reset and event handling thread. The issue may&nbsp;happen when there is heavy IO, device add/delete and SCSI rescan running in the same&nbsp;time.</li></ul>","Lang":"cn"}],"Version":"07.732.03.00"}],"SWKeys":[{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"eb9d8f4ee651453db70f578c42bcca1a"}]},{"ProductId":"4fd1e8e4a27347cd8d83d1e63d9eb38e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000GWKGR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:&nbsp; &nbsp;&nbsp;</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:&nbsp; &nbsp;&nbsp;</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4540104","DateModified":"2025-11-16T11:26:22","FileList":["cp068744.xml","cpqsetup.exe","HVLAeAaseFG1.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"8d7ef938b4b3770d956679fc549a6708","Name":"cp068744.exe","Release":"2025-11-16T11:21:16","Revision":"K","SHA1Sum":"86b305503e55980414c2478bf2ba645ce4835a9f","SHA256Sum":"9babc0351bc59f0b988cff6f69350a2274f32c06efd0b759e07e5d6ea3979001","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWKGR Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB006000GWKGRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB006000GWKGR","TargetGUID":"4d2340a5-3042-3630-3030-3047574b4752","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T07:18:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6f7b50d5341b4904868164eb9b923007"}]},{"ProductId":"e9a54d5b255e4c18936eebffaaff1ccf","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Provides out of band management system with OS-level Agentless Management information and Active Health System events. "},{"Lang":"cn","Value":"提供具有操作系统级Agentless Management信息和Active Health系统事件的带外管理系统。 "},{"Lang":"ja","Value":"帯域管理システム以外を、OS-レベルエージェントレス管理情報とアクティブヘルスシステムのイベントで提供します。 "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>IML events marked as repaired in ILO will not be mirrored in Windows Event Log.</li><li>Recommend user enables code integrity policy after AMS installed.</li><li>If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,&nbsp; but it cannot be uninstalled.&nbsp; To uninstall AMS, the Device Guard policy needs to be temporarily disabled.</li><li>AMS Control Panel applet &ldquo;SNMP&rdquo; tab does not show SNMP settings and does not allow test trap generation<br />&nbsp; when iLO5 encryption is set to SuiteB NSA mode.&nbsp; Please use iLO5-&gt;Management page as an alternate option</li><li>AMS may exhibit slow memory consumption increase in Windows Task Manager. This is due to known WMI (Windows Management Instrumentation)&nbsp;issue in Microsoft Windows. It is expected be fixed in future Microsoft Windows updates or versions. To slow down memory consumption either:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1. Restart&nbsp; the AMS service (type &#39;net stop ams&#39; followed by &#39;net start ams&#39; in a command prompt) ...OR...</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2. Create a new DWORD registry value named PollInterval&nbsp;in registry&#39;s HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\hpeams\\Parameters and set its value to higher than decimal 300. This value will determine&nbsp; how often (in seconds)&nbsp;AMS&nbsp;reads data from WMI.</p>"},{"Lang":"ja","Value":"<ul><li>iLOで修復済みとマークされたIMLイベントは、Windowsイベントログでは反映されません。</li><li>ユーザーはAMSのインストール後にコード整合性ポリシーを有効にすることを推奨します。</li><li>Windows Server 2016 Device Guardポリシーが有効になっている場合は、AMSを古いバージョンから新しいバージョンにアップグレードできますが、AMSをアンインストールすることはできません。  AMSをアンインストールするには、Device Guardポリシーを一時的に無効にする必要があります。</li><li>iLO5暗号化がSuiteB NSAモードに設定されているときは、AMSコントロールパネルアプレットの[SNMP]タブに<br />  SNMP設定が表示されず、テストトラップ生成が許可されません。  iLO5->マネジメントページを代替オプションとして使用してください</li><li>AMSは、Windowsタスクマネージャーでゆっくりとしたメモリ消費量の増加を示す場合があります。これは、Microsoft WindowsのWMI（Windows Management Instrumentation）の既知の問題によるものです。今後のMicrosoft Windowsのアップデートまたはバージョンで修正される予定です。メモリ消費を遅くするには、次のいずれかを実行します。</li></ul><p>             1. AMSサービスを再起動します（コマンドプロンプトで'net stop ams'と入力し、次に'net start ams'と入力します）...または...</p><p>             2. レジストリのHKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\hpeams\\ParametersにPollIntervalという名前の新しいDWORDレジストリ値を作成し、その値を10進数の300より大きい値に設定します。この値により、AMSがWMIからデータを読み取る頻度（秒単位）が決定されます。</p>"},{"Lang":"cn","Value":"<ul><li>IML events marked as repaired in ILO will not be mirrored in Windows Event Log.</li><li>Recommend user enables code integrity policy after AMS installed.</li><li>If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,&nbsp; but it cannot be uninstalled.&nbsp; To uninstall AMS, the Device Guard policy needs to be temporarily disabled.</li><li>AMS Control Panel applet &ldquo;SNMP&rdquo; tab does not show SNMP settings and does not allow test trap generation<br />&nbsp; when iLO5 encryption is set to SuiteB NSA mode.&nbsp; Please use iLO5-&gt;Management page as an alternate option</li><li>AMS may exhibit slow memory consumption increase in Windows Task Manager. This is due to known WMI (Windows Management Instrumentation)&nbsp;issue in Microsoft Windows. It is expected be fixed in future Microsoft Windows updates or versions. To slow down memory consumption either:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1. Restart&nbsp; the AMS service (type &#39;net stop ams&#39; followed by &#39;net start ams&#39; in a command prompt) ...OR...</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2. Create a new DWORD registry value named PollInterval&nbsp;in registry&#39;s HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\hpeams\\Parameters and set its value to higher than decimal 300. This value will determine&nbsp; how often (in seconds)&nbsp;AMS&nbsp;reads data from WMI.</p>"}],"Files":[{"Bytes":"19746976","DateModified":"2025-11-16T18:04:07","FileList":["ams.cab","ams.msi","cp068139.xml","cpqsetup.exe","install.xml","multisetup.dll","SmaInstall.cab","VC_redist.x64.exe"],"MD5Sum":"4dd111f5f68c550b59ab582ed5b26f84","Name":"cp068139.exe","Release":"2025-11-16T18:01:22","Revision":"","SHA1Sum":"20ad02db980c91e424d6784b6705bb528f90ac7a","SHA256Sum":"6246a28ee5b1dbd55404b6dc3cb672be0373d69f5dc9bdfeafaa8937c6f72945","Size":"18MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8b303467"],"TypeOfChange":"1","Version":"2.70.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/verbose_log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the service installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてサービスのインストールを実行します。</p>"},{"Lang":"cn","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the service installation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service for Microsoft Windows x64"},{"Lang":"cn","Value":"Agentless Management Service for Microsoft Windows x64"},{"Lang":"ja","Value":"Agentless Management Service for Microsoft Windows x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-09-07T06:21:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"2.60.3.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"2.70.0.0"}],"SWKeys":[{"Name":"ams.exe","SWKeyExpectedPath":"%ProgramFiles%\\OEM\\AMS\\service"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"613927fcc48e44a1b8df9d2bbdf64f7b"}]},{"ProductId":"057a33153b064c9280dd7da9d3d5a47a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNLおよびEG002400JWJNN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"3255016","DateModified":"2025-11-15T03:57:17","FileList":["cp068764.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA15SEE0HPD6.rel"],"MD5Sum":"85cf11bab2fb0f03273e13e0041c3ce8","Name":"cp068764.exe","Release":"2025-11-15T03:52:05","Revision":"B","SHA1Sum":"661882dd7108534a10e81a247ba00c5e8d66a0c3","SHA256Sum":"4f9f1ebbe58cc133ca56a62c3e5cbd2d0269b17d1d27c0610496d27d70d41885","Size":"3MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EG002400JWJNN","TargetGUID":"452340a5-3047-3230-3430-304a574a4e4e","Type":"sas"},{"Id":"EG001800JWJNL","TargetGUID":"452340a5-3047-3130-3830-304a574a4e4c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T09:48:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスの改訂により、ドライブ全体のパフォーマンスが向上します。</li><li>このファームウェアにアップグレードしない場合、特定のエラーおよびタイミング条件下でドライブがハングアップする可能性が高まります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>このメンテナンスの改訂により、ドライブ全体のパフォーマンスが向上します。</li><li>このファームウェアにアップグレードしない場合、特定のエラーおよびタイミング条件下でドライブがハングアップする可能性が高まります。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5388d296fb844a3388089e9558420c7a"}]},{"ProductId":"1cadb74f384743de9dfa8d9d6bc9f7b5","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000GWJRRおよびMB008000GWJRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"18119791","DateModified":"2025-03-06T12:52:59","FileList":["/CP066013_BUILD_8.data","/CP066013.vmexe64","/CP066013.vmfile","/CP066013_VMw.zip","/CP066013.xml","/payload.json","/CP066013_VMw.zip/index.xml","/CP066013_VMw.zip/vendor-index.xml","/CP066013_VMw.zip/metadata.zip","/CP066013_VMw.zip/vib20/CP066013/HPE_bootbank_CP066013_HPG6.8-1OEM.800.1.0.20613240.vib","/CP066013_VMw.zip/metadata.zip/vendor-index.xml","/CP066013_VMw.zip/metadata.zip/vmware.xml","/CP066013_VMw.zip/metadata.zip/vibs/CP066013-4129019086507507800.xml","/CP066013_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066013_HPG6.8-1OEM.800.1.0.20613240.xml"],"MD5Sum":"78e224992e9c50a6c9997e155400829a","Name":"CP066013.zip","Release":"2025-03-06T12:52:11","Revision":"C","SHA1Sum":"8ec9637ba2c4b2d2a09f2b419b59da21a7aafca0","SHA256Sum":"c2c0c6521c01ce6c24f3d1ef11e3b72e2f12e8bf5cac24c3a85865d6aaa22522","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP066013","Version":"HPG6.8-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041677.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000GWJRT","TargetGUID":"4d2340a5-3042-3830-3030-3047574a5254","Type":"sata"},{"Id":"MB006000GWJRR","TargetGUID":"4d2340a5-3042-3630-3030-3047574a5252","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:41:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4d7a555d818942488b362fa21fb30dcf"}]},{"ProductId":"ad3fba5acbb54355b6ab78730e8d2635","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"cn","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1415832","DateModified":"2025-11-16T05:02:17","FileList":["cp069548.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"MD5Sum":"77b2f777320b712efbac0fcc2feb20d9","Name":"cp069548.exe","Release":"2025-11-16T04:48:40","Revision":"B","SHA1Sum":"723355aac544c7a5bd2ae944be220ba8305e3410","SHA256Sum":"47bdba1961ea3bfa50cb03015433dedfdf9d253e889654f89fd500c7673cfa85","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.17.63.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel iavf Driver for Windows Server 2025"},{"Lang":"ja","Value":"Intel iavf Driver for Windows Server 2025"},{"Lang":"cn","Value":"Intel iavf Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"}],"SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4c184ffadc0949299bd3d8afade1e443"}]},{"ProductId":"43699ba116594728bcf30612b7c6f5f5","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41599","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41599","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41599","Version":"235.1.164.14"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57504 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57504 Gigabit Ethernet NIC firmware."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57504 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 235.1.164.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE</td><td colspan=\"1\" rowspan=\"6\">235.1.164.6<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 235.1.164.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE</td><td colspan=\"1\" rowspan=\"6\">235.1.164.6<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 235.1.164.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE</td><td colspan=\"1\" rowspan=\"6\">235.1.164.6<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"6\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"2802391","DateModified":"2025-12-11T09:43:21","FileList":["BCM235.1.164.14_BCM957504-P425H.HPb","BCM235.1.164.14_BCM957504-P425H.xml","payload.json"],"MD5Sum":"940b46351d7a453802fb9bf70de4cbeb","Name":"BCM235.1.164.14_BCM957504-P425H.fwpkg","Release":"2025-12-11T09:39:23","Revision":"","SHA1Sum":"072379012c51039655b210c8384ddbdeb4e7ded7","SHA256Sum":"bbb685e06a6a73a3d02b10aefa877159484541b3d32a0d39b83147b4688e0953","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180414e41599"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter"},{"Lang":"ja","Value":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-11T07:47:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"BCM_NXE_57504_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"68e09648e9764dac9d7aab181e14de5b"}]},{"ProductId":"a83500e26a4d4bb89a4eb5821b7b2ca6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System"},{"Lang":"ja","Value":"ドライバ - システム"},{"Lang":"cn","Value":"驱动程序 - 系统"}],"Description":[{"Lang":"en","Value":"This components installs the AMD PSHED service"},{"Lang":"ja","Value":"このコンポーネントはAMD PSHEDサービスをインストールします"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"632296","DateModified":"2025-11-16T14:31:19","FileList":["cp069671.xml","cpqsetup.exe","installer.dll","non-pnp/","non-pnp/amdpshed.cat","non-pnp/amdpshed.inf","non-pnp/amdpshed.sys"],"MD5Sum":"f662abeaa2a2cedc74bc301058e1148b","Name":"cp069671.exe","Release":"2025-11-16T14:29:29","Revision":"E","SHA1Sum":"ad153c974328ce7e3b78e0a6513ff350038b46aa","SHA256Sum":"785613fcd43e7ed2a1919081d78aa855f6570c9a94daf836f2cdf4b6b5677481","Size":"617KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"TypeOfChange":"1","Version":"1.0.0.51"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"AMD PSHED Plug-in service for Microsoft Windows Server 2022 and 2025"},{"Lang":"ja","Value":"AMD PSHEDプラグインサービスfor Microsoft Windows Server 2022および2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"100"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-16T14:16:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Software Category</li></ul>","Fixes":"<ul><li>Updated installer.dll</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>アップデートされたソフトウェアカテゴリ</li></ul>","Fixes":"<ul><li>アップデートされた installer.dll</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Software Category</li></ul>","Fixes":"<ul><li>Updated installer.dll</li></ul>","Lang":"cn"}],"Version":"1.0.0.51"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility&nbsp;dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility&nbsp;dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility&nbsp;dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.51"}],"SWKeys":[{"Name":"amdpshed.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"77c0abf6e6e340938e331cc9e83e5a7f"}]},{"ProductId":"6cc89934ad1740b582b096e05315f04a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6503881","DateModified":"2025-09-17T12:39:05","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/CP068849.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/WLEBsssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068849.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068849.scexe"],"MD5Sum":"126bf54ad5ee4ab7e79d167fd40b7681","Name":"firmware-hdd-cfd7436fcc-HPD4-5.1.x86_64.rpm","Release":"2025-09-17T17:28:05","Revision":"E","SHA1Sum":"4056985b475febfd2df1eb4cb7fbb571f9f25503","SHA256Sum":"05ade18957696c64389159ec24bcad642b6468fe5fb58c0cc1db68d77c6e69c4","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP041518.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWUDBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JWUDB","TargetGUID":"4d2340a5-3042-3431-3030-304a57554442","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:19:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RHEL 10のサポートを追加しました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"07622a2605684dfc8bb07322b6903c83"}]},{"ProductId":"423cc31f15944616b9452d63683a53fd","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19766009","DateModified":"2025-07-04T04:49:08","FileList":["/CP067701_BUILD_1.data","/CP067701.vmexe64","/CP067701.vmfile","/CP067701_VMw.zip","/CP067701.xml","/payload.json","/CP067701_VMw.zip/index.xml","/CP067701_VMw.zip/vendor-index.xml","/CP067701_VMw.zip/metadata.zip","/CP067701_VMw.zip/vib20/CP067701/HPE_bootbank_CP067701_HPD4.1-8.0.0.20613240.vib","/CP067701_VMw.zip/metadata.zip/vendor-index.xml","/CP067701_VMw.zip/metadata.zip/vmware.xml","/CP067701_VMw.zip/metadata.zip/vibs/CP067701-926526033685503457.xml","/CP067701_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067701_HPD4.1-8.0.0.20613240.xml"],"MD5Sum":"d3c3f4aa849213c60cb9a377289ec36c","Name":"CP067701.zip","Release":"2025-07-04T04:48:18","Revision":"B","SHA1Sum":"aeeff6ebb2116485a7f59c11b2e8c6c74e86a802","SHA256Sum":"5166ed48551a2971cf8e078580d4c6ae834ca777295a0c202f8bfeec9ccef6ed","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP067701","Version":"HPD4.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP042550.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO003840XZCLT","TargetGUID":"562340a5-304f-3330-3834-30585a434c54","Type":"sas"},{"Id":"MO001600XZCLV","TargetGUID":"4d2340a5-304f-3130-3630-30585a434c56","Type":"sas"},{"Id":"MO000800XZCLQ","TargetGUID":"4d2340a5-304f-3030-3830-30585a434c51","Type":"sas"},{"Id":"VO007680XZCMB","TargetGUID":"562340a5-304f-3730-3638-30585a434d42","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-01T15:01:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a28746b429054472b94b13e27c3d717e"}]},{"ProductId":"f18fb22c5eab4952b3cc28771ba83857","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、MB018000GYDKR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5901951","DateModified":"2025-09-17T12:28:20","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/CP068838.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/SHPEEVSBPTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068838.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068838.scexe"],"MD5Sum":"9497dbf385eb2a7dee9eca3d0482e9d3","Name":"firmware-hdd-4fbb6d96e5-HPG3-2.1.x86_64.rpm","Release":"2025-09-17T17:18:05","Revision":"B","SHA1Sum":"a2d00408c228de1796f0120ddccd8473e7ede6bc","SHA256Sum":"91206b784baba0f3f8c897ca499f5f42d47e5d754e1178e97292b334db620fa2","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、およびMB018000GYDKRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000GYDKP","TargetGUID":"4d2340a5-3042-3031-3030-304759444b50","Type":"sata"},{"Id":"MB016000GYDKQ","TargetGUID":"4d2340a5-3042-3631-3030-304759444b51","Type":"sata"},{"Id":"MB018000GYDKR","TargetGUID":"4d2340a5-3042-3831-3030-304759444b52","Type":"sata"},{"Id":"MB012000GYCJL","TargetGUID":"4d2340a5-3042-3231-3030-304759434a4c","Type":"sata"},{"Id":"MB014000GYCJT","TargetGUID":"4d2340a5-3042-3431-3030-304759434a54","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T17:56:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6022262f43ce41b4a042d38bdece9fcf"}]},{"ProductId":"a3ac88993616476a8dcf9b3fac5ea67c","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"235.1.164014"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"235.1.164014"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"235.1.164014"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"235.1.164014"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"235.1.164014"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs firmware running under Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このパッケージには、Microsoft Windows Server 2022およびWindows Server 2025で動作するHPE ProLiant Broadcom NetXtreme-E Ethernet NICのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"10341112","DateModified":"2025-12-17T11:50:15","FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp070092.xml","cpqsetup.exe","FW/","FW/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","FW/535T-2x10-14E4-16D8-1590-020C.PKG","FW/536I-2x10-14E4-16D6-1590-0230.pkg","FW/537SFP-2x10-14E4-16D7-1590-02C3.pkg","FW/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","FW/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","FW/631SFP28-2x25-14E4-16D7-1590-020E.PKG","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"67b5df3f3cf728d3c49626b0dcb53ee1","Name":"cp070092.exe","Release":"2025-12-17T11:42:08","Revision":"","SHA1Sum":"f8237388c7eb7381bb04ce7c5127a89535d1063c","SHA256Sum":"dbd8b478db43f502d2b99c211b64b351d1da1c191b3cbb50eb9b867c04dcab2e","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"5.4.6.5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> </p><p>［インストール］ボタンをクリックして、インストールを開始します。</p><p> </p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップグレードする場合は、リビジョン履歴を参照し、必要なバージョンまで一つずつアップグレードしていきます。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2026-01-17T07:53:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"5.4.6.0"},{"ReleaseNotes":[{"Enhancements":"<p>BCM235_GCA2</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>BCM235_GCA2</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>BCM235_GCA2</p>","Fixes":"","Lang":"cn"}],"Version":"5.4.6.5"}],"SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"e703974c87ff44f7806534339a848d80"}]},{"ProductId":"75fceb5f9b96474d8e651b3560059cbc","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us</a></li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us</a></li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"3674680","DateModified":"2025-08-03T00:05:50","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-1.1/CP067322.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-1.1/KPE80X0AHPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067322.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067322.scexe"],"MD5Sum":"d8bdad7909fb6c5e5f3c5bfe9820de5c","Name":"firmware-hdd-035a863453_0HPK5-1.1_amd64.deb","Release":"2025-08-03T04:58:16","Revision":"","SHA1Sum":"8ba3837dace0509d8d3ceee51e502663062d12f5","SHA256Sum":"3dd6ffab3c7624cb1bc780b7de5214c49b2d6cde282eb55e95a41514bed2b9cd","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"Installation":{"Command":"CP042953.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO000960KXAVL","TargetGUID":"562340a5-304f-3030-3936-304b5841564c","Type":"nvme"},{"Id":"MO000800KXAVN","TargetGUID":"4d2340a5-304f-3030-3830-304b5841564e","Type":"nvme"},{"Id":"MO001600KXAVT","TargetGUID":"4d2340a5-304f-3130-3630-304b58415654","Type":"nvme"},{"Id":"MO003200KXAVU","TargetGUID":"4d2340a5-304f-3330-3230-304b58415655","Type":"nvme"},{"Id":"MO006400KXAVV","TargetGUID":"4d2340a5-304f-3630-3430-304b58415656","Type":"nvme"},{"Id":"VO003840KXAVQ","TargetGUID":"562340a5-304f-3330-3834-304b58415651","Type":"nvme"},{"Id":"VO007680KXAVR","TargetGUID":"562340a5-304f-3730-3638-304b58415652","Type":"nvme"},{"Id":"VO001920KXAVP","TargetGUID":"562340a5-304f-3130-3932-304b58415650","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:22:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li></ul>","Lang":"cn"}],"Version":"HPK5"}],"SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"010ea8e4097f4b7b9150aa174141a877"}]},{"ProductId":"eea0fcde2dfe4c0ebeb9ed47ea130474","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 8.0"},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;2.9.2.0.</p>"},{"Lang":"ja","Value":"<p>この製品には、ドライバーバージョン2.9.2.0が含まれています。</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;2.9.2.0.</p>"}],"Files":[{"Bytes":"311297","DateModified":"2025-09-22T03:44:46","FileList":["/cp068940.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/index.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/vib20/i40en/INT_bootbank_i40en_2.11.1.0-1OEM.800.1.0.20613240.vib","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/i40en--1194971387421857736.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"52c18946cc68a6d1fd788b719d7272cf","Name":"cp068940.zip","Release":"2025-09-22T03:44:39","Revision":"","SHA1Sum":"65ced9a62f7fbb1b5c5535b0d448d8b5f9e884a7","SHA256Sum":"dac8fbb3846f7add1f74eefd8b823a625598bb4862e37a032b554f840d3f7a05","Size":"304KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"i40en","Version":"2.11.1.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャ、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40en Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE Intel i40enドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Intel i40en Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T01:56:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product addressed the multicast traffic handling on PF0.</li><li>This product addressed the per-queue statistics for native mode.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、PF0上のマルチキャストトラフィックの処理に対処しました。</li><li>この製品は、ネイティブモードのためのキューごとの統計に対処しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the multicast traffic handling on PF0.</li><li>This product addressed the per-queue statistics for native mode.</li></ul>","Lang":"cn"}],"Version":"2024.11.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"Intel-i40en:2.11.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.11.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e7138154c03743fcb5a6b72d23bcf93e"}]},{"ProductId":"6d1e58e8f89340958bf7818046e9b7c7","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2019用のドライバーを含みます。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2461936","DateModified":"2025-11-17T01:28:15","FileList":["cp068341.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"a61125c5428a416a3905af7fb6fe8f37","Name":"cp068341.exe","Release":"2025-11-17T01:13:52","Revision":"","SHA1Sum":"89d2bb5edab9bd6f7b2a4db65bd319790abbf3df","SHA256Sum":"6bc9c7c0cf0fec60bf23bb655545fc6833876cc680f33059ef1c2b8bfd0e0bde","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.7.26882.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2019"},{"Lang":"cn","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815900246","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-13T02:38:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"en"},{"Enhancements":"<p>Windows上のDOCAテレメトリライブラリに対するサポートが追加されました。</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"ja"},{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"cn"}],"Version":"25.4.26768.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"cn"}],"Version":"25.7.26882.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5e4add36c4a843b6ac139031c04abfe0"}]},{"ProductId":"d00882018d64492aa4a5bc81f394c4dc","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A46_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34237576","DateModified":"2026-01-13T02:36:55","FileList":["A46_4.00_01_09_2026.signed.flash","cp070340.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"2c680cb4e277f7402a2c67bc470fc49b","Name":"cp070340.exe","Release":"2026-01-13T02:34:31","Revision":"","SHA1Sum":"146bbcf22a33cd8ef33a44df25bb8280584693f7","SHA256Sum":"e42195a11ae945aab6392742485bcd0693b0cd525297fcd3142a8567e5ecedc8","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) Server"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:33:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.92_11-27-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"0b5f34e8f48c46cbaf7095b45694d07e"}]},{"ProductId":"ce7e63b5ed004965a0bc6af06ca584ef","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3663897","DateModified":"2026-01-15T10:22:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1/CP070010.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-24.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070010.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070010.scexe"],"MD5Sum":"bb4a03e2f57220dfd6e2a8de3559ea49","Name":"firmware-d6020-2.74-24.1.x86_64.rpm","Release":"2026-01-15T16:12:11","Revision":"X","SHA1Sum":"c54a19fffe733e296e29f171c3a112c716b7dfeb","SHA256Sum":"b3bc4587652fc796440b3b79478e5a1aebe84d96e8d1ef6bf77c454eaffd844b","Size":"3MB","TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"Installation":{"Command":"setup","CommandParams":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d6020-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d6020-&lt;version&gt;-*&#39; location</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e,&nbsp;--reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f,&nbsp; --force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g,&nbsp;--downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s,&nbsp;--silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v279106/20-D6020-Gen10RN274X_ED22.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d6020-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d6020-&lt;version&gt;-*&#39; location</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e,&nbsp;--reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f,&nbsp; --force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g,&nbsp;--downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s,&nbsp;--silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v279106/20-D6020-Gen10RN274X_ED22.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d6020-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d6020-&lt;version&gt;-*&#39; location</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e,&nbsp;--reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f,&nbsp; --force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g,&nbsp;--downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s,&nbsp;--silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v279106/20-D6020-Gen10RN274X_ED22.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"ja","Value":"HPE D6020 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"},{"Lang":"cn","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D6020","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-09T10:24:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Rhel 7.8のサポートを追加しました </p></li><li><p>Rhel 8.2のサポートを追加しました </p></li><li><p>SLES15 SP2のサポートを追加しました</p></li></ul>","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li>gSEPモデルとSESデータベース内の温度センサーロジック</li><li>IOMが引き出されたときに、残っているIOMが正しくない異常温度を報告する</li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support ofRHEL 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v279106/20-D6020-Gen10RN274X_ED22.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>RHEL 8.7のサポートを追加</p></li><li><p>RHEL 9.1のサポートを追加 </p></li><li><p>SLES15 SP4のサポートを追加</p></li></ul>","Fixes":"<p><strong>以下の修正がこのバージョンに含まれました：</strong></p><ul><li>gSEPモデルとSESデータベース内の温度センサーロジック</li><li>IOMが引き出されたときに、残っているIOMが正しくない異常温度を報告する</li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v279106/20-D6020-Gen10RN274X_ED22.html\">リリースノート<u></u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support ofRHEL 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v279106/20-D6020-Gen10RN274X_ED22.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"}],"SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ea88112c3acc420f98c7c51a25243bf2"}]},{"ProductId":"7a409aa1e5444a57b8b10f884c98ae5f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the vxn driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel ixt 10 Gigabit Ethernet NIC用のvxnドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the vxn driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"852552","DateModified":"2025-11-16T04:04:13","FileList":["cp069555.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"MD5Sum":"7c11652e5caef801ed72dc27a382a07d","Name":"cp069555.exe","Release":"2025-11-16T03:50:20","Revision":"B","SHA1Sum":"24c02f01035020d7f566addc560bcbc1e3d905aa","SHA256Sum":"cf9f66125d626cb6777d05e4779d150fd30d923ce400f590dc084ce4ef833139","Size":"832KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"TypeOfChange":"1","Version":"2.1.252.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel vxn Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel vxnドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel vxn Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"211B","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c211b","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、新しいファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.252.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、新しいファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.252.0"}],"SWKeys":[{"Name":"vxn68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6d1aec5f11a746129491eab02c7b6005"}]},{"ProductId":"c6a4f7a1c0f14173802a4263b3ee7551","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a false indication of rare capacitor test failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a false indication of rare capacitor test failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"5303213","DateModified":"2025-09-21T19:53:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/4IYRHPG7.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/CP068904.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068904.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068904.scexe"],"MD5Sum":"82a6f57cc7ae659b5f7a452313bd66d3","Name":"firmware-hdd-c566d63ca0-HPG7-6.1.x86_64.rpm","Release":"2025-09-22T00:40:17","Revision":"F","SHA1Sum":"860c1aa2ec2b50bc8842395e7b15a4215466b410","SHA256Sum":"1840c6ca0deeaf1933ed0fbc31f3a91af570711f63889d0e4dafbfa6522c88ec","Size":"5MB","TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"Installation":{"Command":"CP040783.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK003840GWTTD","TargetGUID":"562340a5-304b-3330-3834-304757545444","Type":"sata"},{"Id":"MK003840GWTTN","TargetGUID":"4d2340a5-304b-3330-3834-30475754544e","Type":"sata"},{"Id":"VK001920GWTTC","TargetGUID":"562340a5-304b-3130-3932-304757545443","Type":"sata"},{"Id":"MK001920GWTTL","TargetGUID":"4d2340a5-304b-3130-3932-30475754544c","Type":"sata"},{"Id":"VK000960GWTTB","TargetGUID":"562340a5-304b-3030-3936-304757545442","Type":"sata"},{"Id":"MK000960GWTTK","TargetGUID":"4d2340a5-304b-3030-3936-30475754544b","Type":"sata"},{"Id":"VK000480GWTTA","TargetGUID":"562340a5-304b-3030-3438-304757545441","Type":"sata"},{"Id":"MK000480GWTTH","TargetGUID":"4d2340a5-304b-3030-3438-304757545448","Type":"sata"},{"Id":"VK000240GWTSV","TargetGUID":"562340a5-304b-3030-3234-304757545356","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:41:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes a false indication of rare capacitor test failure</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes a false indication of rare capacitor test failure</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes a false indication of rare capacitor test failure</li></ul>","Lang":"cn"}],"Version":"HPG7"}],"SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7ad7b70347e749eb8fa34cb98fa66144"}]},{"ProductId":"968a9e036afd4092af43608fa1a5a87c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000JXMTH and MB020000JXMTP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB018000JXMTHおよびMB020000JXMTP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4364256","DateModified":"2025-11-16T13:52:21","FileList":["cp068739.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SLONGSPKESD3.rel"],"MD5Sum":"888d3d942a8b4cd5309eac52d275a1b2","Name":"cp068739.exe","Release":"2025-11-16T13:46:21","Revision":"C","SHA1Sum":"f504b1a99ed489c0d59054d9fef246ee33ba9c13","SHA256Sum":"6518d6c36ee3fcd9bf2eb8e64c03d39dc5258b19854754723bd4f9f9045cb357","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB018000JXMTH and MB020000JXMTP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB018000JXMTHおよびMB020000JXMTPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB020000JXMTP","TargetGUID":"4d2340a5-3042-3032-3030-304a584d5450","Type":"sas"},{"Id":"MB018000JXMTH","TargetGUID":"4d2340a5-3042-3831-3030-304a584d5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T05:38:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"03a98050888847a781c6cde05e1c2e53"}]},{"ProductId":"87793aff72a54849a327ce026784372d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1082904","DateModified":"2025-11-16T13:58:22","FileList":["cp069517.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"262b770ab8499b88155a43105c962525","Name":"cp069517.exe","Release":"2025-11-16T13:43:25","Revision":"B","SHA1Sum":"4a75724a1d957874f5c6a78f9fe72d90061406e3","SHA256Sum":"bc2dcd0cea62dcb64ddff2f0411dffe73bd632cbc640d04c170f7f219666ec0e","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"TypeOfChange":"1","Version":"14.0.7.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel E1R Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel E1Rドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel E1R Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T06:29:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>機能変更: E1Rドライバーからの仮想化の削除。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"cn"}],"Version":"14.0.7.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>機能変更: E1Rドライバーからの仮想化の削除。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"cn"}],"Version":"14.0.7.0"}],"SWKeys":[{"Name":"e1r68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"03c3b9c44d5a47e2909fe84d5fe897b1"}]},{"ProductId":"e79fad26938d4b788f99ac1b9d5aa529","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Initial Release</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />     オンラインROMフラッシュコンポーネントfor Windows - HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーファームウェア</p><p><strong>リリースバージョンおよび/または日付:</strong><br />     NA<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     NA<br /><br /><strong>前のファームウェアバージョン：</strong><br />     NA<br /><br /><strong>ファームウェアの関連性：</strong><br />     なし<br /><br /><strong>改善点/新しい機能：</strong></p><ul><li>最初のリリース</li></ul><p><strong>修正された問題点：</strong></p><p><strong>     </strong>なし</p><p><strong>既知の問題点:</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Initial Release</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3748984","DateModified":"2025-11-14T02:23:14","FileList":["Capitola-Release-1.27.bin.fw","cp067914.xml","cpqsetup.exe","payload.json","setup.dll"],"MD5Sum":"ff484dfca5ab583b6dacee66f7ceb090","Name":"cp067914.exe","Release":"2025-11-14T02:13:09","Revision":"F","SHA1Sum":"77ab5498ec7d3ab143561e871d5d1f51cbaaeafb","SHA256Sum":"53c2faf21729c4da78199d8771a62fb9e794a9590231cf3f7a99e98533233260","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant </a><strong>:</strong></strong></p><p>&nbsp;</p><ul><li>Place the desired firmware to be updated in the directory, \\SPPxxxxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant</a></strong>から以下の手順に従ってください：</p><p> </p><ul><li>アップデートに必要なファームウェアを\\SPPxxxxxxx\\packagesディレクトリにコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant </a><strong>:</strong></strong></p><p>&nbsp;</p><ul><li>Place the desired firmware to be updated in the directory, \\SPPxxxxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware Windows (x64) - HPE Apollo 2000 Gen10 PlusバックプレーンエキスパンダーFW"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Id":"Apollon2800Gen10Plus","TargetGUID":"","Type":"agp"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-23T06:19:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support Azure Stack HCI 23H2.&nbsp;</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support Azure Stack HCI 23H2.&nbsp;</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support Azure Stack HCI 23H2.&nbsp;</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.27"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.27"}],"SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5bd325460cd446faaf9c162a70f2502d"}]},{"ProductId":"9797527c9a7541debadf0b96aae4c9b3","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08ADAnG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3430-3030-3047575a5654","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB004000GWZVT"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MB004000GWZVT"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB004000GWZVT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1271550","DateModified":"2024-07-09T03:49:16","FileList":["payload.json","Toshiba_MG08Air_TAMG08ADAnG3.HPb","Toshiba_MG08Air_TAMG08ADAnG3.xml"],"MD5Sum":"11a12a97fdc85c0d5728dcf69363d995","Name":"Toshiba_MG08Air_TAMG08ADAnG3.fwpkg","Release":"2024-07-09T03:45:20","Revision":"","SHA1Sum":"fde1ea65f338efa599f73c4ba2d71e02e92ffbf2","SHA256Sum":"c6bb621e978e8c5760bdefa134779c4265431722a3e5060d37f52eaf60bfea4a","Size":"1MB","TargetGUIDs":["4d2340a5-3042-3430-3030-3047575a5654"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MB004000GWZVT"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  MB004000GWZVT"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MB004000GWZVT"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB004000GWZVT","TargetGUID":"4d2340a5-3042-3430-3030-3047575a5654","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-08-09T00:59:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB004000GWZVT","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"9077ed7856b1465a8395a8ce4b5e9a97"}]},{"ProductId":"2232e2b621a84f55a544f2a4ed765213","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VMK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />      オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VMK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ</p><p><strong>リリースバージョンおよび/または日付:<br />      </strong>HPG1<br /><br /><strong>最新の推奨またはクリティカルバージョン：<br />      </strong>なし<br /><br /><strong>前のファームウェアバージョン：</strong><br />      なし</p><p><strong>ファームウェアの関連性：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"}],"Files":[{"Bytes":"21434641","DateModified":"2025-03-06T11:42:14","FileList":["/CP065947_BUILD_4.data","/CP065947.vmexe64","/CP065947.vmfile","/CP065947_VMw.zip","/CP065947.xml","/payload.json","/CP065947_VMw.zip/index.xml","/CP065947_VMw.zip/vendor-index.xml","/CP065947_VMw.zip/metadata.zip","/CP065947_VMw.zip/vib20/CP065947/HPE_bootbank_CP065947_HPG1.4-1OEM.800.1.0.20613240.vib","/CP065947_VMw.zip/metadata.zip/vendor-index.xml","/CP065947_VMw.zip/metadata.zip/vmware.xml","/CP065947_VMw.zip/metadata.zip/vibs/CP065947--2574758972881357601.xml","/CP065947_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065947_HPG1.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"c15851175c1223f6257c4d9823115a10","Name":"CP065947.zip","Release":"2025-03-06T11:41:25","Revision":"C","SHA1Sum":"25de5953c63467cba9e44310fa679ce647623e7a","SHA256Sum":"fa4955802766ed99cd89b52cf8b4ec6f48ea39adb97ace426003d6baca1ee1f1","Size":"20MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065947","Version":"HPG1.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040671.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives."},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VMK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MK000480GZXRA","TargetGUID":"4d2340a5-304b-3030-3438-30475a585241","Type":"sata"},{"Id":"MK001920GZXRC","TargetGUID":"4d2340a5-304b-3130-3932-30475a585243","Type":"sata"},{"Id":"MK000960GZXRB","TargetGUID":"4d2340a5-304b-3030-3936-30475a585242","Type":"sata"},{"Id":"MK003840GZXRV","TargetGUID":"4d2340a5-304b-3330-3834-30475a585256","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:33:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d9ce784d3c6446d0a0b58f1fc7bafd70"}]},{"ProductId":"0a96bc740aee4364b774edfa452ca9a4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3249592","DateModified":"2025-11-15T04:25:15","FileList":["cp068761.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA14SXn0HPD9.REL"],"MD5Sum":"8b3e0b9e334081141a4ef1022264500c","Name":"cp068761.exe","Release":"2025-11-15T04:19:12","Revision":"B","SHA1Sum":"0b28732d2c1fdb1eec129fb44593983d1d82837f","SHA256Sum":"615cbe017d733f7b1ef0f76ea738d25cae6aa6c8b67bb57314a56fcd128cf356","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EH000300JWHPL","TargetGUID":"452340a5-3048-3030-3330-304a5748504c","Type":"sas"},{"Id":"EH000600JWHPN","TargetGUID":"452340a5-3048-3030-3630-304a5748504e","Type":"sas"},{"Id":"EH000900JWHPP","TargetGUID":"452340a5-3048-3030-3930-304a57485050","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T09:18:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスの改訂により、ドライブ全体のパフォーマンスが向上します。</li><li>このファームウェアにアップグレードしない場合、特定のエラーおよびタイミング条件下でドライブがハングアップする可能性が高まります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>このメンテナンスの改訂により、ドライブ全体のパフォーマンスが向上します。</li><li>このファームウェアにアップグレードしない場合、特定のエラーおよびタイミング条件下でドライブがハングアップする可能性が高まります。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"636289ed1ad14379824d9cf5cad217d1"}]},{"ProductId":"4aaa1b96312a4790820f2c40ac3eb0e7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MM1000JFJTH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000JFJTH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JFJTH Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JFJTH Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19175696","DateModified":"2025-03-06T07:03:39","FileList":["/CP066005_BUILD_4.data","/CP066005.vmexe64","/CP066005.vmfile","/CP066005_VMw.zip","/CP066005.xml","/payload.json","/CP066005_VMw.zip/index.xml","/CP066005_VMw.zip/vendor-index.xml","/CP066005_VMw.zip/metadata.zip","/CP066005_VMw.zip/vib20/CP066005/HPE_bootbank_CP066005_HPD5.4-8.0.0.20613240.vib","/CP066005_VMw.zip/metadata.zip/vendor-index.xml","/CP066005_VMw.zip/metadata.zip/vmware.xml","/CP066005_VMw.zip/metadata.zip/vibs/CP066005--9038234977815441205.xml","/CP066005_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066005_HPD5.4-8.0.0.20613240.xml"],"MD5Sum":"16a1cc8bc6f17fb66efb0f60d1a1ab80","Name":"CP066005.zip","Release":"2025-03-06T07:02:50","Revision":"E","SHA1Sum":"49963f960ef9c70f3d4d803afa08f0224925c9f1","SHA256Sum":"0785d4a222d482b8e38b00962be0011a6e0eb256d7fa1e04e99aead96b3164e4","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-4d00-314d-3030-304a464a5448"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP066005","Version":"HPD5.4-8.0.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JFJTH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MM1000JFJTHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MM1000JFJTH","TargetGUID":"002340a5-4d00-314d-3030-304a464a5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:03:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MM1000JFJTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"accf85e27715420fa50c2afc082f49f0"}]},{"ProductId":"e951bbca527f4f9f8a089c23c99574fe","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"854984","DateModified":"2025-11-16T02:59:15","FileList":["cp069557.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs.cat","vxs.inf","vxs.sys","vxsmsg.dll"],"MD5Sum":"ff268ea4f478192320232b0a7a234a4e","Name":"cp069557.exe","Release":"2025-11-16T02:45:03","Revision":"D","SHA1Sum":"09942e65288920fd12619af67a12656b84abe2ea","SHA256Sum":"b3a3671a7f40b0e30bd8ee80363192910f5bef92e20950c5f24252b714db7178","Size":"834KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"TypeOfChange":"1","Version":"2.3.2.4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel vxs Driver for Windows Server 2022"},{"Lang":"ja","Value":"Windows Server 2022用HPE Intel vxsドライバー"},{"Lang":"cn","Value":"HPE Intel vxs Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1565","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d1","Type":"pci","Ven":"8086"},{"Dev":"1564","Type":"pci","Ven":"8086"},{"Dev":"1565","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d2","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"cn"}],"Version":"2.3.2.4"},{"ReleaseNotes":[{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"cn"}],"Version":"2.3.2.4"}],"SWKeys":[{"Name":"vxs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\vxs.inf_amd64_d6120d6ae1cc028c"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1156f09e64bb44e8a0ac79c721f3e0ba"}]},{"ProductId":"b81956d2c370432aad5ffc0ea6fc40b3","Versions":[{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Power Management"},{"Lang":"ja","Value":"ファームウェア - パワー マネジメント"},{"Lang":"cn","Value":"固件 - 电源管理"}],"Description":[{"Lang":"en","Value":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたアドバンスト消費電力上限マイクロコントローラーファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"683448","DateModified":"2025-11-14T03:21:17","FileList":["cp069607.xml","cpqsetup.exe","LICENSE.txt","payload.json","PICGen10_v1.1.4_hdr.signed.hex","SecureFlash64.dll"],"MD5Sum":"d72a3d1f75ff4b161d64668a9500d5e8","Name":"cp069607.exe","Release":"2025-11-14T03:19:29","Revision":"D","SHA1Sum":"f37922cfcb32c0ab27f57886127205222c0118b9","SHA256Sum":"eff91846781264d2ec7fddd521ac097395e732e87ae7113e1d5315febbb1c1b7","Size":"667KB","TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />&nbsp;</p><p>This component can only be executed on Windows x64.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。 <br /> </p><p>このコンポーネントは、Windows x64上でのみ実行できます。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />&nbsp;</p><p>This component can only be executed on Windows x64.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュ for Windows x64 - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen10およびGen10 Plus、ML30 Gen11サーバー"},{"Lang":"cn","Value":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T03:17:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"}],"SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DX360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"7bdaa82f3b0243c79e8496b11331da87"}]},{"ProductId":"87b9a1c22150406cbf61d6b300753282","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000GWJRRおよびMB008000GWJRTドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improvement in mixed READ/WRITE performance, which was causing a field issue at an HPE customer -&nbsp;Improve random mix performance in TL=2048k and 512k</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improvement in mixed READ/WRITE performance, which was causing a field issue at an HPE customer -&nbsp;Improve random mix performance in TL=2048k and 512k</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5137385","DateModified":"2025-09-17T12:47:46","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/CP068856.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/TAMG06ACHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068856.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068856.scexe"],"MD5Sum":"6f474dbc5c2f8f5aac2d1b927fdadedd","Name":"firmware-hdd-c993b31232-HPG6-7.1.x86_64.rpm","Release":"2025-09-17T17:36:05","Revision":"G","SHA1Sum":"f042b7b3fd37a879b025b1e286e020ef0e676742","SHA256Sum":"e7fdcc658931d881dbbdd51c23b3d06ec5797d0326377555cc3e5d7416084c99","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP041676.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000GWJRT","TargetGUID":"4d2340a5-3042-3830-3030-3047574a5254","Type":"sata"},{"Id":"MB006000GWJRR","TargetGUID":"4d2340a5-3042-3630-3030-3047574a5252","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:39:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b55a0487e34c45578e26e301d0a3bc62"}]},{"ProductId":"3013cefa4fe14260a6f6811796f9b1c0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. "},{"Lang":"ja","Value":"HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"31769733","DateModified":"2025-08-19T09:17:38","FileList":["./etc/init.d/LsiSASH","./opt/HPEMRSA/LSIStorageAuthority","./opt/HPEMRSA/LSIStorageAuthority/bin","./opt/HPEMRSA/LSIStorageAuthority/bin/LSA","./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so.4","./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib8.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so","./opt/HPEMRSA/LSIStorageAuthority/bin/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer","./opt/HPEMRSA/LSIStorageAuthority/bin/storelib8conf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconfit.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/temp","./opt/HPEMRSA/LSIStorageAuthority/conf","./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf","./opt/HPEMRSA/LSIStorageAuthority/conf/languages","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr8_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_errors_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode8.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs","./opt/HPEMRSA/LSIStorageAuthority/logs","./opt/HPEMRSA/LSIStorageAuthority/plugins","./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/report","./opt/HPEMRSA/LSIStorageAuthority/server","./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win","./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types","./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/docs","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru","./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/README","./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/html","./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-Chg-Personality.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure1-InstallShieldWizardDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure2-PortConfigurationSettingsDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure3-DestinationFolderDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure4-ConfigureRangeOfEventsToGenerateAlertNotifications.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_NVMe_Thermal_Poll_Interval.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_alert_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_writecache_policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_changing_behavior_modes.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ChangeDrive-Security.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure21-EnableTheUnmapFeatureDuringVolumeCreation.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ManagePCIe-Storage-Interface2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/Replace-a-Missing-Drive.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/config-login-no-login-localhost-remote-access.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-lsa-spin-down.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-spin-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-hpe-nvram-clear.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-nvme-thermal-poll-interval.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v10550932.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036741.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036763.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036906.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11169464.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049673.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049745.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12382402.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13111710.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13292421.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v26717125.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v8285855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9157473.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9506612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9508081.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery-1.4.2.1-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery.flexslider-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery_page_top_arrow.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/1370F7A6BA15F932ABC2CD3083B97DDD.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/D27EEE45B074A44BC7BEE885A75C289C.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/FBEEC26C1FC5A6C6CE967B685C48BB53.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/A651E792C5B1FFE8C7A2FF01DBDA7D28.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/13517E860F6874F70EDF25750E13016A.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/ACC3F85EC285012679DBC35184BE5E5E.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/logs","./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log","./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log","./opt/HPEMRSA/LSIStorageAuthority/server/nginx","./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/start.log","./opt/HPEMRSA/LSIStorageAuthority/server/temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9","./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh","./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh","./usr/lib/.build-id","./usr/lib/.build-id/00","./usr/lib/.build-id/00/6409b5707928d043f68afe4991697e50b79671","./usr/lib/.build-id/00/6409b5707928d043f68afe4991697e50b79671.1","./usr/lib/.build-id/0b","./usr/lib/.build-id/0b/32aaf88c1e414a9a9af7de3139abbd2d3e34a0","./usr/lib/.build-id/11","./usr/lib/.build-id/11/78f660015bcd48cc7e7d5e9d7b84fefe9c7470","./usr/lib/.build-id/11/ca56459476a06053afee3b8e0cba491c420c86","./usr/lib/.build-id/1e","./usr/lib/.build-id/1e/d82579e740ef91bd7925299955ef4fcb9da651","./usr/lib/.build-id/1e/d82579e740ef91bd7925299955ef4fcb9da651.1","./usr/lib/.build-id/1f","./usr/lib/.build-id/1f/c577d68d0107e86be04c1d6585803316182799","./usr/lib/.build-id/35","./usr/lib/.build-id/35/791fe646fb821530d06d83e1559b30eded30f3","./usr/lib/.build-id/3b","./usr/lib/.build-id/3b/1737aec5827787d454c28a9fb4a2902c1691fe","./usr/lib/.build-id/3e","./usr/lib/.build-id/3e/92220a201aa84dee762fab7a95ab79efe15379","./usr/lib/.build-id/3e/92220a201aa84dee762fab7a95ab79efe15379.1","./usr/lib/.build-id/69","./usr/lib/.build-id/69/634d282a5acf1996cfd0836ddf65a032d681b9","./usr/lib/.build-id/69/634d282a5acf1996cfd0836ddf65a032d681b9.1","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/4ddf43f85d29be91e0ed25d4ad7b1254fab378","./usr/lib/.build-id/6c/4ddf43f85d29be91e0ed25d4ad7b1254fab378.1","./usr/lib/.build-id/7d","./usr/lib/.build-id/7d/a8527c34f88cf8663eef30ee9b87eec57534ba","./usr/lib/.build-id/8a","./usr/lib/.build-id/8a/31da29980b2679e925179e642d7345ce8ab5a7","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/12e9baa47f8f05096c26585d622e8399db8b42","./usr/lib/.build-id/8c/12e9baa47f8f05096c26585d622e8399db8b42.1","./usr/lib/.build-id/9a","./usr/lib/.build-id/9a/2c2c59759eb882a97627247db6b0e93fd5a776","./usr/lib/.build-id/9a/a5387b0fb3dba5c160df369f136a245bb80d99","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/196810755f0eef617025b491d1a9a794eb6de4","./usr/lib/.build-id/a1/196810755f0eef617025b491d1a9a794eb6de4.1","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/3c0fedca07dacb44a6d4146d9b0e6314676fc0","./usr/lib/.build-id/cf","./usr/lib/.build-id/cf/c4093ce682b4099d4294bc3232dc9218cf4425","./usr/lib/.build-id/cf/c4093ce682b4099d4294bc3232dc9218cf4425.1","./usr/lib/.build-id/e6","./usr/lib/.build-id/e6/14c16894270f516cb00291b96cdb3991a2499d","./usr/lib/.build-id/f7","./usr/lib/.build-id/f7/3fc0a213962551ba8bf1b21613e0ad84c85a71","./usr/lib/.build-id/f7/3fc0a213962551ba8bf1b21613e0ad84c85a71.1","./usr/lib/.build-id/fd","./usr/lib/.build-id/fd/ae2c340afce4b32ab2b4ef635757f036270131","./usr/share/smartupdate/MRStorageAdministrator/component.xml"],"MD5Sum":"96db584395c64b1af9edc6adcdb8cacc","Name":"MRStorageAdministrator-008.012.052.000-00.rhel10.x86_64.rpm","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"b7a8a44251eaa433b25d2c5ec1852805f1c114a1","SHA256Sum":"bb77bae16e37f4cdcc0816c73adb271e25c4267a6243f502bf08263e44648ff1","Size":"30MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"TypeOfChange":"1","Version":"8.12.52.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li><li>Use &quot;rpm&nbsp;-Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li><li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li></ul>"},{"Lang":"ja","Value":"<ul><li>HPEMRSAはRed Hat Package Manager (RPM) パッケージを用いて配布されます。</li><li>古いバージョンのHPEMRSAがシステムにインストールされている場合、\"rpm -e <rpm_name>\"を使用して最初にそれを削除してください。</li><li>\"rpm  -Uvh --oldpackage --replacefiles –replacepkgs <rpm_name>\"を使用してアプリケーションをインストールします。</li><li>RPMに関する詳細については \"man rpm\" と入力します。</li><li>ソフトウェアはopt/HPEMRSA/LSIStorageAuthorityにあります。</li><li>/opt/HPEMRSA/LSIStorageAuthorityにあるStartupLSAUI.shを実行して、MRSAを起動します。</li></ul>"},{"Lang":"cn","Value":"<ul><li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li><li>Use &quot;rpm&nbsp;-Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li><li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator for RHEL10 (HPE MRSA for Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator for RHEL10 (HPE MRSA for Gen10PおよびGen11コントローラー)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator for RHEL10 (HPE MRSA for Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T04:23:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Change the backplane bay count information to the actual bay that is connected to controller.</li><li>Add support for users to clear NVRAM using Factory Repurpose operation</li><li>Re-order LSA GUI buttons<ul><li>Move the Rebuild button to the top before Make Online button</li><li>Add the Rebuild button in the Offline Drive warning session</li></ul></li><li>Change the recommended action for Degarded Volume to &ldquo;Make sure all the&nbsp;participating drives are connected and rebuild is complete&rdquo;.</li></ul>","Fixes":"<ul><li>Fix MRSA issue in a00150411en_us Advisory: HPE Compute MR Controllers - HPE MR Storage Administrator (MRSA) Launch Issue and Storage Command Line Interface&nbsp;(StorCLI) Installation Warning Message Observed With Red Hat Enterprise Linux Server&nbsp;10</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。</li><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加</li><li>LSA GUIボタンの順序を変更<ul><li>[Rebuild]ボタンを[Make Online]ボタンの前に移動</li><li>オフラインドライブの警告セッションに[Rebuild]ボタンを追加</li></ul></li><li>劣化したボリュームの推奨アクションを[Make sure all the participating drives are connected and rebuild is complete]に変更。</li></ul>","Fixes":"<ul><li>a00150411en_usアドバイザリのMRSAの問題を修正: HPE Compute MR Controllers - Red Hat Enterprise Linux Server 10でHPE MR Storage Administrator (MRSA) の起動問題とストレージコマンドラインインターフェイス (StorCLI) のインストールに関する警告メッセージが表示される</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Change the backplane bay count information to the actual bay that is connected to controller.</li><li>Add support for users to clear NVRAM using Factory Repurpose operation</li><li>Re-order LSA GUI buttons<ul><li>Move the Rebuild button to the top before Make Online button</li><li>Add the Rebuild button in the Offline Drive warning session</li></ul></li><li>Change the recommended action for Degarded Volume to &ldquo;Make sure all the&nbsp;participating drives are connected and rebuild is complete&rdquo;.</li></ul>","Fixes":"<ul><li>Fix MRSA issue in a00150411en_us Advisory: HPE Compute MR Controllers - HPE MR Storage Administrator (MRSA) Launch Issue and Storage Command Line Interface&nbsp;(StorCLI) Installation Warning Message Observed With Red Hat Enterprise Linux Server&nbsp;10</li></ul>","Lang":"cn"}],"Version":"8.12.52.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Change the backplane bay count information to the actual bay that is connected to controller.</li><li>Add support for users to clear NVRAM using Factory Repurpose operation</li><li>Re-order MRSA GUI buttons<ul><li>Move the Rebuild button to the top before Make Online button</li><li>Add the Rebuild button in the Offline Drive warning session</li></ul></li><li>Change the recommended action for Degarded Volume to &ldquo;Make sure all the&nbsp;participating drives are connected and rebuild is complete&rdquo;.</li></ul>","Fixes":"<ul><li>Fix MRSA issue in a00150411en_us Advisory: HPE Compute MR Controllers - HPE MR Storage Administrator (MRSA) Launch Issue and Storage Command Line Interface&nbsp;(StorCLI) Installation Warning Message Observed With Red Hat Enterprise Linux Server&nbsp;10</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。</li><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加</li><li>MRSA GUIボタンの順序を変更<ul><li>[Rebuild]ボタンを[Make Online]ボタンの前に移動</li><li>オフラインドライブの警告セッションに[Rebuild]ボタンを追加</li></ul></li><li>劣化したボリュームの推奨アクションを[Make sure all the participating drives are connected and rebuild is complete]に変更。</li></ul>","Fixes":"<ul><li>a00150411en_usアドバイザリのMRSAの問題を修正: HPE Compute MR Controllers - Red Hat Enterprise Linux Server 10でHPE MR Storage Administrator (MRSA) の起動問題とストレージコマンドラインインターフェイス (StorCLI) のインストールに関する警告メッセージが表示される</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Change the backplane bay count information to the actual bay that is connected to controller.</li><li>Add support for users to clear NVRAM using Factory Repurpose operation</li><li>Re-order MRSA GUI buttons<ul><li>Move the Rebuild button to the top before Make Online button</li><li>Add the Rebuild button in the Offline Drive warning session</li></ul></li><li>Change the recommended action for Degarded Volume to &ldquo;Make sure all the&nbsp;participating drives are connected and rebuild is complete&rdquo;.</li></ul>","Fixes":"<ul><li>Fix MRSA issue in a00150411en_us Advisory: HPE Compute MR Controllers - HPE MR Storage Administrator (MRSA) Launch Issue and Storage Command Line Interface&nbsp;(StorCLI) Installation Warning Message Observed With Red Hat Enterprise Linux Server&nbsp;10</li></ul>","Lang":"cn"}],"Version":"8.12.52.0"}],"SWKeys":[{"Name":"MRStorageAdministrator","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"497253d10cf34662af36bb1d5f1e2596"}]},{"ProductId":"b902adf94cea4a0abb9a86aae94c9318","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b58505256","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b58505452","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58505454","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58505455","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b58505255","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b5850544e","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b58505450","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b58505451","Version":"HPK2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK2</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK2</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK2</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"6260888","DateModified":"2024-06-25T10:53:19","FileList":["payload.json","SKHynix_PE81X0_KPE81X0AHPK2.HPb","SKHynix_PE81X0_KPE81X0AHPK2.xml"],"MD5Sum":"86491cdfad6f25c2c6eaf885646357af","Name":"SKHynix_PE81X0_KPE81X0AHPK2.fwpkg","Release":"2024-06-25T10:50:12","Revision":"","SHA1Sum":"a7ca59c7dc75e45555e03abb49e4ffc1766cc53b","SHA256Sum":"07a1568323099b051a4b1576b610a947cd84da072a1d1e04d81883dc7e5a8cfa","Size":"5MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304b58505256","4d2340a5-304f-3130-3630-304b58505452","4d2340a5-304f-3330-3230-304b58505454","4d2340a5-304f-3630-3430-304b58505455","562340a5-304f-3030-3936-304b58505255","562340a5-304f-3130-3932-304b5850544e","562340a5-304f-3330-3834-304b58505450","562340a5-304f-3730-3638-304b58505451"],"TypeOfChange":"1","Version":"HPK2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO000800KXPRV","TargetGUID":"4d2340a5-304f-3030-3830-304b58505256","Type":"nvme"},{"Id":"MO001600KXPTR","TargetGUID":"4d2340a5-304f-3130-3630-304b58505452","Type":"nvme"},{"Id":"MO003200KXPTT","TargetGUID":"4d2340a5-304f-3330-3230-304b58505454","Type":"nvme"},{"Id":"MO006400KXPTU","TargetGUID":"4d2340a5-304f-3630-3430-304b58505455","Type":"nvme"},{"Id":"VO000960KXPRU","TargetGUID":"562340a5-304f-3030-3936-304b58505255","Type":"nvme"},{"Id":"VO001920KXPTN","TargetGUID":"562340a5-304f-3130-3932-304b5850544e","Type":"nvme"},{"Id":"VO003840KXPTP","TargetGUID":"562340a5-304f-3330-3834-304b58505450","Type":"nvme"},{"Id":"VO007680KXPTQ","TargetGUID":"562340a5-304f-3730-3638-304b58505451","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-07-25T10:26:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>&nbsp;This is an initial FW.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p> これは初期FWです。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>&nbsp;This is an initial FW.</p>","Lang":"cn"}],"Version":"HPK0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code improvements for CAP.TO and LED behavior.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code improvements for CAP.TO and LED behavior.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code improvements for CAP.TO and LED behavior.</li></ul>","Lang":"cn"}],"Version":"HPK2"}],"SWKeys":[{"Name":"MO000800KXPRV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXPTR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXPTT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXPTU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KXPRU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXPTN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXPTP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXPTQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"b3ac2dd86a7d4e9aa3340410288c5fcb"}]},{"ProductId":"39676e9bd8d74e11b8837e3f6ebabd5c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of SSA, with the appropriate firmware."},{"Lang":"cn","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of SSA, with the appropriate firmware."},{"Lang":"ja","Value":"Smart Storage Administrator（SSA）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるWebベースのアプリケーションです。Smart Array Advanced Pack 1.0および2.0の機能は、適切なファームウェア(の使用)によりSSAのベースライン機能の一部となりました。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[{"Lang":"en","Value":"<p>Please make sure the following browser options are enabled:</p><ul><li>Automatically load images and other data types.</li><br /><li>JAVA script</li><br /><li>Style sheets</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>Please make sure the following browser options are enabled:</p><ul><li>Automatically load images and other data types.</li><br /><li>JAVA script</li><br /><li>Style sheets</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Please make sure the following browser options are enabled:</p><ul><li>Automatically load images and other data types.</li><br /><li>JAVA script</li><br /><li>Style sheets</li></ul><p>&nbsp;</p>"}],"Files":[{"Bytes":"9784636","DateModified":"2025-12-05T02:15:21","FileList":["./opt/smartstorageadmin/ssa","./opt/smartstorageadmin/ssa/HTML","./opt/smartstorageadmin/ssa/HTML/SSA1","./opt/smartstorageadmin/ssa/HTML/SSA1/css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings","./opt/smartstorageadmin/ssa/HTML/strings/HPE","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/man/man8/ssa.8.gz","./usr/sbin/ssa","./usr/share/smartupdate/ssa/component.xml"],"MD5Sum":"1fbe56802aaa9775eea7c8be3a63436a","Name":"ssa-6.60-8.0.x86_64.rpm","Release":"2025-12-05T02:13:17","Revision":"","SHA1Sum":"f8ba4d69a7034a2012f437b468f5962761c2d970","SHA256Sum":"da006c508316af497d6f52c88998947049a5c0d7f09208510b5339083f60ce2c","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"TypeOfChange":"1","Version":"6.60.8.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs&nbsp;&lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul>"},{"Lang":"cn","Value":"<ul><li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs&nbsp;&lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul>"},{"Lang":"ja","Value":"<ul><li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs&nbsp;&lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) for Linux 64ビット for Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:19:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li></ul>","Lang":"cn"}],"Version":"6.50.11.0"},{"ReleaseNotes":[{"Enhancements":"<p>RC drop 6.60.8.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RC drop 6.60.8.0.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>RC drop 6.60.8.0.</p>","Fixes":"","Lang":"cn"}],"Version":"6.60.8.0"}],"SWKeys":[{"Name":"ssa","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"50cd52f793c142a59934e609300224e8"}]},{"ProductId":"0e486c09859842e29ba327f60bd15f9a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB006000JYDNF, MB008000JYDPC and MB010000JYDNH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"}],"Files":[{"Bytes":"6532227","DateModified":"2025-09-17T11:25:38","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/CP068805.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/SCIMARBPESD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068805.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068805.scexe"],"MD5Sum":"fac448d88ebe7b7a2fe69a57b0bf4c3e","Name":"firmware-hdd-b04df66fe9-HPD5-2.1.x86_64.rpm","Release":"2025-09-17T16:13:03","Revision":"B","SHA1Sum":"cb33486cafbd20d0f1298d22a21169bd35d9edb8","SHA256Sum":"2e17168c58f84f9e4b4626f9bba5c8c35e138c6ab510427abbed453f4f92b556","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000JYDNF、MB008000JYDPCおよびMB010000JYDNHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000JYDNF","TargetGUID":"4d2340a5-3042-3630-3030-304a59444e46","Type":"sas"},{"Id":"MB008000JYDPC","TargetGUID":"4d2340a5-3042-3830-3030-304a59445043","Type":"sas"},{"Id":"MB010000JYDNH","TargetGUID":"4d2340a5-3042-3031-3030-304a59444e48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T03:52:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4e33cb3609b14b61a246f9ddee0de109"}]},{"ProductId":"dcff0c4699e341cf85f18eb94d85147c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品は、Red Hat Enterprise Linux 9下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"157652","DateModified":"2025-10-08T03:42:55","FileList":["./etc/depmod.d/tg3.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/tg3","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/35","./usr/lib/.build-id/35/7efa5f17a7c6e71d942b7f01ea72889bc2eddc","./usr/share/smartupdate/kmod-tg3/component.xml"],"MD5Sum":"6b6a2ed1ca8488134814ee591428414d","Name":"kmod-tg3-3.139w-1.rhel9u6.x86_64.rpm","Release":"2025-10-08T03:38:32","Revision":"","SHA1Sum":"49946a98246d014574303f698dd3d909d092dcbb","SHA256Sum":"4eb840f5fb24188b716c2f491e90b0bd5b173cd80ce202d55c61b8eab299519d","Size":"153KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.139w-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download README for installation notes.</p>"},{"Lang":"ja","Value":"<p>インストールのノートについてREADMEをダウンロードします。</p>"},{"Lang":"cn","Value":"<p>Download README for installation notes.</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T03:19:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes issue where link disconnected with the latest Out-of-Box (OOB) Driver.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、最新の Out-of-Box (OOB) ドライバーでリンクが切断される問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes issue where link disconnected with the latest Out-of-Box (OOB) Driver.</p>","Lang":"cn"}],"Version":"3.139t-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"3.139w-1"}],"SWKeys":[{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03030202","Model":"HPE Compute Scale-up Server 3250"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5c2ad4196c7e42169f6d89cfef5629c4"}]},{"ProductId":"0bb28a52c60e4e09a0da1e6ee82945ae","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Power Coordination algorithm which ensures the drive will properly negotiate power with SPL-2 and newer compliant controllers.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Power Coordination algorithm which ensures the drive will properly negotiate power with SPL-2 and newer compliant controllers.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"4628360","DateModified":"2025-08-03T01:34:54","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-1.1/CP067341.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-1.1/SSKYBT512ND9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067341.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067341.scexe"],"MD5Sum":"fdfca64ababf112dbe5ace77c18e91fb","Name":"firmware-hdd-bdfb8e99d9_0HPD9-1.1_amd64.deb","Release":"2025-08-03T06:29:00","Revision":"","SHA1Sum":"037999df924b644f8f755adecfe5d38fd0cc27d5","SHA256Sum":"cabacd1a57c2cd9362aa1254d8d9f630eea5c491d87bd84c2b8eaf08a1fa3f9a","Size":"4MB","TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP041693.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG001200JWJNQ","TargetGUID":"452340a5-3047-3130-3230-304a574a4e51","Type":"sas"},{"Id":"EG000600JWJNP","TargetGUID":"452340a5-3047-3030-3630-304a574a4e50","Type":"sas"},{"Id":"EG001200MXJQU","TargetGUID":"452340a5-3047-3130-3230-304d584a5155","Type":"sas"},{"Id":"EG000600JXLVV","TargetGUID":"452340a5-3047-3030-3630-304a584c5656","Type":"sas"},{"Id":"EG001200JXLWA","TargetGUID":"452340a5-3047-3130-3230-304a584c5741","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:29:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"880ffde7fc6e496fa172c745e9aca5e6"}]},{"ProductId":"de51682518bb48a2bb985003f8a8df4e","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされるHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3610およびD3710BディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3628803","DateModified":"2025-12-19T09:58:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1/CP070008.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1/Reveille-Release-6.00-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070008.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070008.scexe"],"MD5Sum":"f89289f874c8c6ae0687b05d4acfa801","Name":"firmware-d3000-6.00-11.1.x86_64.rpm","Release":"2025-12-19T15:47:27","Revision":"K","SHA1Sum":"2339f77f131f4c87adc8e041f0caeae7a648a2d8","SHA256Sum":"1c74a5e89ffaeb8262fe812f682f5f409eb2d0355c78eccc466ce3606c495d64","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"Installation":{"Command":"setup","CommandParams":"-t D3600B -t D3610B -t D3700B -t D3710B -v 6.00 -i Reveille-Release-6.00-build-000.bin -l D3000B.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"ja","Value":"HPE D3610B/D3710B 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Linux (x64)"},{"Lang":"cn","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3610B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3710B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-09T10:20:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 8.7&nbsp;</p></li><li><p>Added support of Rhel 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Rhel 8.7のサポートを追加 </p></li><li><p>Rhel 9.1のサポートを追加 </p></li><li><p>SLES15 SP4のサポートを追加</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 8.7&nbsp;</p></li><li><p>Added support of Rhel 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v275930/20-D3000B-Gen10RN600J_ED11.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"6.00"}],"SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ed7288d4d67d44ae9e19be9b0c12c49a"}]},{"ProductId":"66cb80b1d5d040ff8edbcf313b0e2f9d","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08SDAnD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a575a5655","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model: MB004000JWZVU"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB004000JWZVU"},{"Lang":"cn","Value":"This package provides firmware for the following drive model: MB004000JWZVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; N/A</strong><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; N/A</strong><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; N/A</strong><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"}],"Files":[{"Bytes":"1290647","DateModified":"2025-02-19T20:47:20","FileList":["payload.json","Toshiba_MG08Air_TAMG08SDAnD3.HPb","Toshiba_MG08Air_TAMG08SDAnD3.xml"],"MD5Sum":"36ff098bf468f4587388f9c032120ee3","Name":"Toshiba_MG08Air_TAMG08SDAnD3.fwpkg","Release":"2025-02-19T20:45:01","Revision":"B","SHA1Sum":"af61cb6f5c2c9be89d5ba8195154580c88a87bcf","SHA256Sum":"5a3ffcc88bd314c603494722b942ccdc8cf8a9937fb230e0fa70f647d8a1628f","Size":"1MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a575a5655"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB004000JWZVU"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ -  MB004000JWZVU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB004000JWZVU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB004000JWZVU","TargetGUID":"4d2340a5-3042-3430-3030-304a575a5655","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T21:03:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p>&nbsp;</p>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。  このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li></ul><p> </p>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p>&nbsp;</p>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB004000JWZVU","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"cb947df2b7494b02a1ae11bb036e5d53"}]},{"ProductId":"a5e366733eda432d8665f3d8aaa40d56","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18575392","DateModified":"2025-03-07T06:57:29","FileList":["/CP065925_BUILD_5.data","/CP065925.vmexe64","/CP065925.vmfile","/CP065925_VMw.zip","/CP065925.xml","/payload.json","/CP065925_VMw.zip/index.xml","/CP065925_VMw.zip/vendor-index.xml","/CP065925_VMw.zip/metadata.zip","/CP065925_VMw.zip/vib20/CP065925/HPE_bootbank_CP065925_4ICRHPK3.5-8.0.0.20613240.vib","/CP065925_VMw.zip/metadata.zip/vendor-index.xml","/CP065925_VMw.zip/metadata.zip/vmware.xml","/CP065925_VMw.zip/metadata.zip/vibs/CP065925--1260422250758343006.xml","/CP065925_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065925_4ICRHPK3.5-8.0.0.20613240.xml"],"MD5Sum":"5e87e2b9b27ae101a8e79134d5c4f4b4","Name":"CP065925.zip","Release":"2025-03-07T06:56:36","Revision":"H","SHA1Sum":"7143d6150c74e16e85576fde4528adf97ab72749","SHA256Sum":"256d8a603788eaa0e63e454d058830ea56b19357197882e428b8a345061c49ef","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3","VibList":[{"Name":"CP065925","Version":"4ICRHPK3.5-8.0.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MO006400KWVVA","TargetGUID":"4d2340a5-304f-3630-3430-304b57565641","Type":"nvme"},{"Id":"VO004000KWVUR","TargetGUID":"562340a5-304f-3430-3030-304b57565552","Type":"nvme"},{"Id":"MO003200KWVUV","TargetGUID":"4d2340a5-304f-3330-3230-304b57565556","Type":"nvme"},{"Id":"VO002000KWVVC","TargetGUID":"562340a5-304f-3230-3030-304b57565643","Type":"nvme"},{"Id":"MO001600KWVUU","TargetGUID":"4d2340a5-304f-3130-3630-304b57565555","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T06:12:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li _msthash=\"61\" _msttexthash=\"1384240\">Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li _msthash=\"61\" _msttexthash=\"1384240\">コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li _msthash=\"61\" _msttexthash=\"1384240\">Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"}],"SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0d29c281641d41adbcbc3c3426d12e2a"}]},{"ProductId":"c31f4b9416db481caaf570f911d5ccd1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a false indication of rare capacitor test failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a false indication of rare capacitor test failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3607480","DateModified":"2025-07-31T08:22:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-1.1/4IYRHPG7.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-1.1/CP067317.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067317.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067317.scexe"],"MD5Sum":"6020c5dc42d725749b4d3ec21684479a","Name":"firmware-hdd-c566d63ca0_0HPG7-1.1_amd64.deb","Release":"2025-07-31T13:14:07","Revision":"","SHA1Sum":"2d47ae26dcae8c300da6d988d6febe0b36f769ab","SHA256Sum":"2e617af7b51bda8e5be8bd125fff58cd5a41eaa2c338f6cfca52bb4176efebbd","Size":"3MB","TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"Installation":{"Command":"CP040783.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK003840GWTTD","TargetGUID":"562340a5-304b-3330-3834-304757545444","Type":"sata"},{"Id":"MK003840GWTTN","TargetGUID":"4d2340a5-304b-3330-3834-30475754544e","Type":"sata"},{"Id":"VK001920GWTTC","TargetGUID":"562340a5-304b-3130-3932-304757545443","Type":"sata"},{"Id":"MK001920GWTTL","TargetGUID":"4d2340a5-304b-3130-3932-30475754544c","Type":"sata"},{"Id":"VK000960GWTTB","TargetGUID":"562340a5-304b-3030-3936-304757545442","Type":"sata"},{"Id":"MK000960GWTTK","TargetGUID":"4d2340a5-304b-3030-3936-30475754544b","Type":"sata"},{"Id":"VK000480GWTTA","TargetGUID":"562340a5-304b-3030-3438-304757545441","Type":"sata"},{"Id":"MK000480GWTTH","TargetGUID":"4d2340a5-304b-3030-3438-304757545448","Type":"sata"},{"Id":"VK000240GWTSV","TargetGUID":"562340a5-304b-3030-3234-304757545356","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:10:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes a false indication of rare capacitor test failure</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes a false indication of rare capacitor test failure</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes a false indication of rare capacitor test failure</li></ul>","Lang":"cn"}],"Version":"HPG7"}],"SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"71f5230eb7214932998d51f4e9547388"}]},{"ProductId":"865064fe88324b7ea65c940d300f10de","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB018000JXMTH and MB020000JXMTP"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB018000JXMTHおよびMB020000JXMTP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB018000JXMTH and MB020000JXMTP Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB018000JXMTH and MB020000JXMTP Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20315487","DateModified":"2025-03-06T13:25:52","FileList":["/CP065976_BUILD_4.data","/CP065976.vmexe64","/CP065976.vmfile","/CP065976_VMw.zip","/CP065976.xml","/payload.json","/CP065976_VMw.zip/index.xml","/CP065976_VMw.zip/vendor-index.xml","/CP065976_VMw.zip/metadata.zip","/CP065976_VMw.zip/vib20/CP065976/HPE_bootbank_CP065976_HPD3.4-1OEM.800.1.0.20613240.vib","/CP065976_VMw.zip/metadata.zip/vendor-index.xml","/CP065976_VMw.zip/metadata.zip/vmware.xml","/CP065976_VMw.zip/metadata.zip/vibs/CP065976-8794686904810807406.xml","/CP065976_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065976_HPD3.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"40ce2f39bf93879fda6b19cce64c8e9d","Name":"CP065976.zip","Release":"2025-03-06T13:25:09","Revision":"B","SHA1Sum":"53f9bbde5fce39eb4911e0a02fccaa7f8301ab5a","SHA256Sum":"43ef7c98bc16e5528361ebb1e14577c22a86625cc79b67bd9ee4a93c38dffa01","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP065976","Version":"HPD3.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042785.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000JXMTH and MB020000JXMTP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB018000JXMTHおよびMB020000JXMTPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB018000JXMTH","TargetGUID":"4d2340a5-3042-3831-3030-304a584d5448","Type":"sas"},{"Id":"MB020000JXMTP","TargetGUID":"4d2340a5-3042-3032-3030-304a584d5450","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:01:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Assertの修正、現在のファームウェアの改善、およびバグ修正を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2e40f73a1fb54c0abb55aa2da3f59574"}]},{"ProductId":"f74d68169f04405fb74a2820e48df6f5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Video"},{"Lang":"ja","Value":"ドライバ - ビデオ"},{"Lang":"cn","Value":"驱动程序 - 视频"}],"Description":[{"Lang":"en","Value":"This component provides advanced video support for the Matrox G200eH3 video controller."},{"Lang":"ja","Value":"このコンポーネントは、Matrox G200eH3ビデオ コントローラー対応の高度なビデオ機能を提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1618288","DateModified":"2025-11-18T08:02:22","FileList":["cp069736.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","MxG2hDO64.sys","mxg2hs16.cat","MxG2hS16.inf"],"MD5Sum":"82814a7d6e4d074e8a4fe0f555e33496","Name":"cp069736.exe","Release":"2025-11-18T08:00:26","Revision":"G","SHA1Sum":"64f358bb869b419f3c754527f844015a761a4e46","SHA256Sum":"3c76d662a9221b0fa590548e8901d4b9a94630f18e967bcf395f48ec39261df9","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"TypeOfChange":"0","Version":"9.15.1.248"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P><P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P><P>Click the \"Install\" button to perform the driver installation.</P>"},{"Lang":"ja","Value":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P><P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P><P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Matrox G200eH3 Video Controller Driver for Microsoft Windows 64-bit"},{"Lang":"ja","Value":"Matrox G200eH3ビデオコントローラードライバーfor Microsoft Windows 64ビット"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"10000"},"SupportedDevices":[{"Dev":"0538","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-102b-0538159000e4","Type":"pci","Ven":"102B"},{"Dev":"0538","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-102b-05381590027f","Type":"pci","Ven":"102B"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T07:55:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"9.15.1.248"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"9.15.1.248"}],"SWKeys":[{"Name":"MxG2hDO64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"bce54ec69c3c4680beca7054654ab9bd"}]},{"ProductId":"41fa8420de8d497db38df0b5cd7ea429","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Agentless Management Service (AMSD) provides support for HPE Integrated Lights-Out Embedded Health and Alerting."},{"Lang":"ja","Value":"Agentless Management Service（AMSD）は、HPE Integrated Lights Out内蔵ヘルスおよびアラートのサポートを提供します。"},{"Lang":"cn","Value":"Agentless Management Service (AMSD) provides support for HPE Integrated Lights-Out Embedded Health and Alerting."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"6026966","DateModified":"2026-01-23T14:07:14","FileList":["./etc/default/ahslog","./etc/default/amsd","./etc/default/amsd_rev","./etc/default/cpqIde","./etc/default/cpqScsi","./etc/default/cpqiScsi","./etc/default/mr_cpqScsi","./etc/default/smad","./etc/default/smad_rev","./lib/systemd/system/ahslog.service","./lib/systemd/system/amsd.service","./lib/systemd/system/amsd_rev.service","./lib/systemd/system/cpqFca.service","./lib/systemd/system/cpqFca_rev.service","./lib/systemd/system/cpqIde.service","./lib/systemd/system/cpqIde_rev.service","./lib/systemd/system/cpqScsi.service","./lib/systemd/system/cpqScsi_rev.service","./lib/systemd/system/cpqiScsi.service","./lib/systemd/system/mr_cpqScsi.service","./lib/systemd/system/mr_cpqScsi_rev.service","./lib/systemd/system/smad.service","./lib/systemd/system/smad_rev.service","./lib/udev/rules.d/81-cpqFca.rules","./lib/udev/rules.d/81-cpqiScsi.rules","./sbin/ahslog","./sbin/amscli","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqIde","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./sbin/smad","./sbin/smad_rev","./usr/share/amsd/amsd.license","./usr/share/doc/amsd/README.Debian","./usr/share/doc/amsd/changelog.Debian.gz","./usr/share/doc/amsd/copyright","./usr/share/man/man1/ahslog.1m.gz","./usr/share/man/man1/smad.1m.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/smartupdate/amsd/component.xml"],"MD5Sum":"02e278b1afb9ce3d3db940d79fb6064b","Name":"amsd_4.5.0-2107.3-ubuntu22_amd64.deb","Release":"2026-01-23T14:03:10","Revision":"","SHA1Sum":"3ceb44763b749c293ffccea8e1edfbed8144f1e9","SHA256Sum":"d864866d7b1b32b1cb264cf9651174a819f0f813aa5e37bb48a432c8a18e9d06","Size":"5MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.5.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation method:</strong><br />&nbsp;<br />Using dpkg command<br />To install the package, type:</p><ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul></li><li>To check whether the package is loaded properly type:<ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul><li>man amsd</li></ul></li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation method:</strong><br />&nbsp;<br />Using dpkg command<br />To install the package, type:</p><ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul></li><li>To check whether the package is loaded properly type:<ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul><li>man amsd</li></ul></li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation method:</strong><br />&nbsp;<br />Using dpkg command<br />To install the package, type:</p><ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul></li><li>To check whether the package is loaded properly type:<ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul><li>man amsd</li></ul></li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service for Ubuntu 22.04 LTS"},{"Lang":"ja","Value":"Agentless Management Service for Ubuntu 22.04 LTS"},{"Lang":"cn","Value":"Agentless Management Service for Ubuntu 22.04 LTS"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-08T09:04:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"4.4.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"4.5.0"}],"SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:deb"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"da2b5014ad074a43bfd210b806e7c68d"}]},{"ProductId":"14d9773880e140e2bf92c4c4e7a389e3","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5780512","DateModified":"2025-08-03T00:58:27","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-1.1/CP067329.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-1.1/GPM173XAHPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067329.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067329.scexe"],"MD5Sum":"05fa0464f3415018d7699af6f80df3d8","Name":"firmware-hdd-a27c95663d_0HPK6-1.1_amd64.deb","Release":"2025-08-03T05:52:32","Revision":"","SHA1Sum":"d5119cffcdf2e9fd61e304376267edec75d4ce10","SHA256Sum":"1cfb7a632ffc6b6fe67c0b9db6e1ee968d483f63e04ab767e4733eeb8e03824f","Size":"5MB","TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6"}],"Installation":{"Command":"CP041864.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MO001600KYDMU","TargetGUID":"4d2340a5-304f-3130-3630-304b59444d55","Type":"nvme"},{"Id":"MO006400KYDND","TargetGUID":"4d2340a5-304f-3630-3430-304b59444e44","Type":"nvme"},{"Id":"VO015360KYDNB","TargetGUID":"562340a5-304f-3531-3336-304b59444e42","Type":"nvme"},{"Id":"VO007680KYDNA","TargetGUID":"562340a5-304f-3730-3638-304b59444e41","Type":"nvme"},{"Id":"MO003200KYDNC","TargetGUID":"4d2340a5-304f-3330-3230-304b59444e43","Type":"nvme"},{"Id":"VO001920KYDMT","TargetGUID":"562340a5-304f-3130-3932-304b59444d54","Type":"nvme"},{"Id":"VO003840KYDMV","TargetGUID":"562340a5-304f-3330-3834-304b59444d56","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:49:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"HPK6"}],"SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"55d35d7690074d37813f0a6d3ab4980f"}]},{"ProductId":"d32e3e2cf68a47998f06cb81ab591bd1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager and an iLO Advanced Pack license for deployment."},{"Lang":"ja","Value":"Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の認証情報を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerおよび展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。"},{"Lang":"cn","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager and an iLO Advanced Pack license for deployment."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"19694536","DateModified":"2026-01-14T05:45:42","FileList":["./README.txt","./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/lib/x86_64-linux-gnu/libQt5Core.so.5","./opt/sut/lib/x86_64-linux-gnu/libdouble-conversion.so.3","./opt/sut/lib/x86_64-linux-gnu/libicudata.so.70.1","./opt/sut/lib/x86_64-linux-gnu/libicui18n.so.70.1","./opt/sut/lib/x86_64-linux-gnu/libicuuc.so.70.1","./opt/sut/lib/x86_64-linux-gnu/libpcre2-16.so.0","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/share/doc/sut/changelog.gz","./usr/share/doc/sut/copyright","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml","./opt/sut/lib/x86_64-linux-gnu/libicudata.so.70","./opt/sut/lib/x86_64-linux-gnu/libicui18n.so.70","./opt/sut/lib/x86_64-linux-gnu/libicuuc.so.70"],"MD5Sum":"7a99976506aad2351fd073e31e5209c6","Name":"sut-6.5.0-11_amd64.deb","Release":"2026-01-14T05:40:28","Revision":"","SHA1Sum":"246d9d8b8b86d80766fb6a1f9876a259b0b0df8a","SHA256Sum":"daff4223e3fffc613ff3ed60e813a6e20c3b967193c16fbe1ae45072073241fa","Size":"18MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"0","Version":"6.5.0.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the deb package to a directory on your hard drive and change to that directory. Install by typing dpkg -i&nbsp;sut-XXX_amd64deb.</p>"},{"Lang":"ja","Value":"<p>Download the deb package to a directory on your hard drive and change to that directory. Install by typing dpkg -i&nbsp;sut-XXX_amd64deb.</p>"},{"Lang":"cn","Value":"<p>Download the deb package to a directory on your hard drive and change to that directory. Install by typing dpkg -i&nbsp;sut-XXX_amd64deb.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Integrated Smart Update Tools for Ubuntu Linux x64"},{"Lang":"ja","Value":"Integrated Smart Update Tools for Ubuntu Linux x64"},{"Lang":"cn","Value":"Integrated Smart Update Tools for Ubuntu Linux x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"26","Minor":"04","Name":"Ubuntu 26.04 LTS","Platform":"ubuntu2604","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-01T10:16:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>To Do</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TO DO</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>To Do</p>","Lang":"cn"}],"Version":"6.4.0.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>To Do</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TO DO</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>To Do</p>","Lang":"cn"}],"Version":"6.5.0.0"}],"SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:deb"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HP Smart Update Tools (HP SUT)"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"R14","Model":"HPE ProLiant Compute DL384 Gen12 – GH200 96GB"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c6c1c6da68cd41cb80b608d75e757a14"}]},{"ProductId":"3d51e7d6b8674f16bd8f67bee278e11a","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900382","Version":"8.00"},{"DeviceName":"HPE_SR_Gen10_7.99","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.00_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900383","Version":"8.00"}]},"MinimumActiveVersion":"5.61","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the Gen11 SR308i-o, SR308i-p controllers and Gen10 Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m, P816i-a and SR308i-o,SR308i-p Gen11 SR controllers"},{"Lang":"ja","Value":"ユニバーサルファームウェアPLDMファイルfor Gen11 SR308i-o, SR308i-pコントローラーおよびGen10 Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m, P816i-aおよびSR308i-o,SR308i-p Gen11 SRコントローラー"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the Gen11 SR308i-o, SR308i-p controllers and Gen10 Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m, P816i-a and SR308i-o,SR308i-p Gen11 SR controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12115516","DateModified":"2025-12-04T08:04:48","FileList":["HPE_SR_Gen10_8.00_A.HPb","HPE_SR_Gen10_8.00_A.xml","payload.json"],"MD5Sum":"aac9c06d86c66fe6e02ee4e20681fa3a","Name":"HPE_SR_Gen10_8.00_A.fwpkg","Release":"2025-12-04T07:59:56","Revision":"","SHA1Sum":"a3f30f0026021887599e4a606d4ac4b1dd76234a","SHA256Sum":"f62d49254f206f0241c62ef939cde430e44694cb58a354db447db1fc5864933b","Size":"11MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f15900383"],"TypeOfChange":"1","Version":"8.00"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>&nbsp; &nbsp; Reboot the server for the firmware update to take effect.</p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager (SUM) を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/connect/s/product?language=en_US&kmpmoid=7630408&tab=driversAndSoftware&driversAndSoftwareFilter=8000078\">iLO Restfulインターフェイスツール</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>    ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>    ファームウェアアップデートを有効にするためにサーバーを再起動します。</p><p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>     アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>&nbsp; &nbsp; Reboot the server for the firmware update to take effect.</p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package  - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m and P816i-a SR Gen10 and SR308i-o,SR308i-p Gen11 controllers"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408e-m、P204i-c、P416ie-m、およびP816i-a SR Gen11コントローラー"},{"Lang":"cn","Value":"Firmware Package  - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m and P816i-a SR Gen10 and SR308i-o,SR308i-p Gen11 controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"12000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-11-14T05:08:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added SSD life expectancy monitoring.&nbsp;</li><li>Added support to require privileged operations token for all RDE ACTION operations, including Drive.Reset and Storage.SetEncryptionKey, improving security for data-destructive actions.&nbsp;</li><li>Added support to provide meaningful updateInterval values for Numeric Sensor PDRs, setting 5 seconds for controller temperature and 60 seconds for drive temperature sensors.&nbsp;</li><li>Enhanced the calculation of CapacityBytes@Redfish.AllowableNumbers for Volume Capabilities. The maximum allowable value is now set to the larger of (a) the largest free space range on any existing array, or (b) the sum of unassigned drives with a common interface and media type.&nbsp;</li><li>Enhanced DriveMetrics support by updating the schema version from 1.0.0 to 1.2.0, adding reporting for ReadIOKiBytes and WriteIOKiBytes properties.&nbsp;</li><li>Added an enhancement to display drive vendor and model name as separate fields in the Disk Information menu, improving clarity and ease of drive identification.&nbsp;</li><li>Added support to securely transfer encryption keys in remote key management mode.&nbsp;</li><li>Enhanced drive writes cache status reporting in HII.&nbsp;</li></ul>","Fixes":"<ul><li>Fixed an issue where SEDs reverting to foreign after controller reboot due to the otherwise owned flag not being saved to the datastore.&nbsp;</li><li>Fixed an issue where firmware crash/lockup during NDSR (Non-Disruptive Software Reset) due to a NULL pointer reference when handling a failed drive during logical drive rebuilt.&nbsp;</li><li>Fix 4Kn foreign SED being imported into a 512B logical drive due to incorrect failure handling, which could start a rebuild on an incompatible drive and ultimately fail.&nbsp;</li><li>Fixed an issue where multiple logical drives incorrectly showing REBUILDING simultaneously due to rebuild status not being updated properly during queued transformation and rebuild processes&nbsp;</li><li>Fixed an issue where master key change failure on Managed SED logical drives due to LU cache flush requests conflicting with the password update process.&nbsp;</li><li>Fixed an issue where physical drive Predictive Failure status not reported correctly by tools and iLO.&nbsp;</li><li>Fixed an issue where controller lockup during surface scan caused by stale internal resources when handling Unrecoverable Read Errors (UREs) in unmapped logical drive regions.&nbsp;</li><li>Fixed an issue where uncorrectable DDR ECC errors could be reported at boot due to cache being accessed before initialization.&nbsp;</li><li>Fixed an issue where the controller could lock up (0x3120C) when enabling MCP due to duplicate routing entries from flooded BMC requests.&nbsp;</li><li>Fixed an issue where SATA drives could be incorrectly reported as hot-removed during spin-up by adjusting the dampen timer to align with vendor-specified TTR values.&nbsp;</li><li>Fixed an issue where the controller could lock up (0x1E30) under high I/O workloads when configuration changes occurred simultaneously with a LUN reset.&nbsp;</li><li>Fixed an issue where RAID 0 could hang with I/O timeouts and LUN resets during Predictive Spare Rebuild.&nbsp;</li><li>Fixed an issue where the RAID controller could incorrectly report Online Firmware Activation as enabled. Firmware now checks support during PQI initialization and sets or clears the feature flags accordingly.&nbsp;</li><li>Fixed an issue where drives in some enclosures could show bay number 255 after the enclosure was powered on and hot-plugged, by adding handling for additional SCSI not ready status codes until the enclosure becomes ready.&nbsp;</li><li>Fixed an issue where Micron 6550 SED drives could fail to create a Secured Volume due to insufficient timeout during the TCG Revert process.&nbsp;</li><li>Fixed an issue where the controller Health state from PLDM PDRs could differ from the Storage.Status.HealthRollup value in RDE, by synchronizing the reporting logic.&nbsp;</li><li>Fixed an issue where SSD firmware updates could fail in dual path configurations due to PLDM errors, by sending Test Unit Ready commands to clear check conditions before SCSI passthrough operations.&nbsp;</li><li>Fixed an issue where Battery Redfish Alerts contained an incorrect OriginOfCondition pointing to a StorageController instead of the Battery resource.&nbsp;</li><li>Fixed an issue where RDE UPDATE operations on a Volume&rsquo;s ReadCachePolicy could incorrectly appear successful during a CBE rekey, by adjusting the cache update logic to return accurate results regardless of cache status.&nbsp;</li><li>Fixed an issue where the HotspareActivationPolicy allowable values incorrectly included OnDriveFailure for RAID 0 volumes with a dedicated spare, by adding configuration checks to ensure only valid values are shown.&nbsp;</li><li>Fixed an issue where there is a mismatch in Overall Health State and Logical Volume State during RPI, with sensors reporting Warning (Overall Health) while RDE READs ( Logical Volume State) showed OK; reporting OK during RPI is exxpected behavior.&nbsp;</li><li>Fixed an issue where ProtectedWriteBack could incorrectly appear as an allowable WriteCachePolicy in RDE READs even without a backup power source, by requiring the power source to be connected and fully charged before publishing the option.&nbsp;</li><li>Fixed an issue where an RDE READ on certain unsupported Drive resources could cause a controller lockup, by adding bounds checking in the firmware API.&nbsp;</li><li>Fixed an issue where deleting volumes through PLDM Type 6 could cause a controller lockup if other PLDM commands were sent simultaneously. These commands now return NOT_READY when a long-running RDE operation is in progress.&nbsp;</li><li>Fixed an issue where disk utilities could display an invalid box number for drives after failing over to an alternative path, by ensuring only valid controller-provided information is shown.&nbsp;</li><li>Fixed an issue where an incorrect error message was shown in HII when creating a logical drive on a locked SED, by updating the error message to correctly reflect SED encryption.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>SSD寿命の監視を追加しました。 </li><li>Drive.ResetおよびStorage.SetEncryptionKeyを含むすべてのRDE ACTION操作に特権操作トークンを要求するサポートが追加され、データ破壊アクションのセキュリティが向上しました。 </li><li>数値センサーPDRに意味のあるアップデート間隔値を提供するためのサポートが追加されました。コントローラー温度の場合は5秒、ドライブ温度センサーの場合は60秒に設定します。 </li><li>ボリューム機能のCapacityBytes@Redfish.AllowableNumbersの計算が強化されました。最大許容値は、(a) 既存のアレイ上の最大空き領域範囲、または (b) 共通のインターフェースとメディア タイプを持つ未割り当てドライブの合計のうち大きい方に設定されます。 </li><li>スキーマバージョンを1.0.0から1.2.0にアップデートし、ReadIOKiBytesおよびWriteIOKiBytesプロパティのレポートを追加することで、DriveMetricsのサポートが強化されました。 </li><li>ディスク情報メニューでドライブのベンダー名とモデル名を個別のフィールドとして表示する機能強化が追加され、ドライブの識別が明確になり、容易になりました。 </li><li>リモートキー管理モードで暗号化キーを安全に転送するためのサポートが追加されました。 </li><li>HIIでのドライブ書き込みキャッシュステータスレポートが強化されました。 </li></ul>","Fixes":"<ul><li>コントローラーの再起動後に、所有フラグがデータストアに保存されていないために SED が外部に戻ってしまう問題を修正しました。 </li><li>論理ドライブの再構築中に障害が発生したドライブを処理するときに、NULL ポインタ参照が原因で NDSR (非中断型ソフトウェア リセット) 中にファームウェアがクラッシュ/ロックアップする問題を修正しました。 </li><li>誤った障害処理により 4Kn 外部 SED が 512B 論理ドライブにインポートされ、互換性のないドライブで再構築が開始され、最終的に失敗する可能性がある問題を修正しました。 </li><li>キューされた変換および再構築プロセス中に再構築ステータスが適切にアップデートされないため、複数の論理ドライブが同時に誤って「REBUILDING」と表示される問題を修正しました。 </li><li>LU キャッシュ フラッシュ要求がパスワードアップデートプロセスと競合するため、管理対象 SED 論理ドライブでマスター キーの変更が失敗する問題を修正しました。 </li><li>物理ドライブの予測障害ステータスがツールおよび iLO によって正しく報告されない問題を修正しました。 </li><li>マップされていない論理ドライブ領域で回復不可能な読み取りエラー (URE) を処理するときに、古い内部リソースが原因で表面スキャン中にコントローラーがロックアップする問題を修正しました。 </li><li>初期化前にキャッシュがアクセスされたために、起動時に修正不可能なDDR ECCエラーが報告される可能性がある問題を修正しました。 </li><li>フラッディングされたBMC要求からの重複したルーティングエントリーが原因でMCPを有効にするとコントローラーがロックアップする (0x3120C) 問題を修正しました。 </li><li>ベンダー指定のTTR値に合わせてダンプタイマーを調整することにより、スピンアップ中にSATAドライブがホットリムーブされたと誤って報告される可能性がある問題を修正しました。 </li><li>LUNリセットと同時に構成の変更が発生した場合、I/Oワークロードが高いときにコントローラーがロックアップする (0x1E30) 可能性がある問題を修正しました。 </li><li>予測スペア再構築中に RAID 0がI/OタイムアウトとLUNリセットでハングする可能性がある問題を修正しました。 </li><li>RAIDコントローラーがオンラインファームウェアアクティベーションを誤って有効であると報告する可能性がある問題を修正しました。ファームウェアは、PQI初期化中にサポートをチェックし、それに応じて機能フラグを設定またはクリアするようになりました。 </li><li>エンクロージャが準備完了になるまで追加のSCSI準備完了ステータスコードの処理を追加することにより、エンクロージャの電源がオンになってホットプラグされた後に、一部のエンクロージャ内のドライブがベイ番号 255 を表示する可能性がある問題を修正しました。 </li><li>TCG復帰プロセス中にタイムアウトが不十分なためにMicron 6550 SEDドライブがセキュアボリュームを作成できない問題を修正しました。 </li><li>レポートロジックを同期することにより、PLDM PDRからのコントローラーのヘルス状態がRDEの Storage.Status.HealthRollup値と異なる可能性がある問題を修正しました。 </li><li>SCSIパススルー操作の前にチェック条件をクリアするためにTest Unit Readyコマンドを送信することにより、PLDMエラーが原因でデュアル パス構成でSSDファームウェアのアップデートが失敗する可能性がある問題を修正しました。 </li><li>Battery Redfish アラートに、バッテリー リソースではなくStorageControllerを指す誤った OriginOfCondition が含まれていた問題を修正しました。 </li><li>キャッシュアップデートロジックを調整して、キャッシュの状態に関係なく正確な結果を返すことにより、CBEキー再生成中にボリュームのReadCachePolicyに対するRDE UPDATE操作が誤って成功したように見える問題を修正しました。 </li><li>有効な値のみが表示されるように構成チェックを追加することで、専用スペアを持つ RAID 0ボリュームのHotspareActivationPolicy許容値にOnDriveFailureが誤って含まれていた問題を修正しました。 </li><li>RPI中に全体的なヘルス状態と論理ボリューム状態に不一致があり、RDE READ (論理ボリューム状態) がOKを示しているのにセンサーが警告 (全体的なヘルス) を報告する問題を修正しました。RPI中に OKを報告することは想定された動作です。 </li><li>オプションを公開する前に電源を接続して完全に充電する必要があるため、バックアップ電源がない場合でも、ProtectedWriteBackがRDE READで許容されるWriteCachePolicyとして誤って表示される可能性がある問題を修正しました。 </li><li>ファームウェアAPIに境界チェックを追加することで、サポートされていない特定のドライブリソースに対するRDE READによってコントローラーがロックアップする可能性がある問題を修正しました。 </li><li>他のPLDMコマンドが同時に送信された場合に PLDMタイプ6を介してボリュームを削除するとコントローラーがロックアップする可能性がある問題を修正しました。これらのコマンドは、長時間実行されるRDE操作の進行中にNOT_READYを返すようになりました。 </li><li>コントローラーが提供する有効な情報のみが表示されるようにすることで、代替パスにフェイルオーバーした後にディスク ユーティリティがドライブの無効なボックス番号を表示する可能性がある問題を修正しました。 </li><li>ロックされたSED上に論理ドライブを作成するときにHIIに誤ったエラーメッセージが表示される問題を修正しました。この問題を修正するために、エラー メッセージをアップデートし、SED暗号化を正しく反映しました。 </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added SSD life expectancy monitoring.&nbsp;</li><li>Added support to require privileged operations token for all RDE ACTION operations, including Drive.Reset and Storage.SetEncryptionKey, improving security for data-destructive actions.&nbsp;</li><li>Added support to provide meaningful updateInterval values for Numeric Sensor PDRs, setting 5 seconds for controller temperature and 60 seconds for drive temperature sensors.&nbsp;</li><li>Enhanced the calculation of CapacityBytes@Redfish.AllowableNumbers for Volume Capabilities. The maximum allowable value is now set to the larger of (a) the largest free space range on any existing array, or (b) the sum of unassigned drives with a common interface and media type.&nbsp;</li><li>Enhanced DriveMetrics support by updating the schema version from 1.0.0 to 1.2.0, adding reporting for ReadIOKiBytes and WriteIOKiBytes properties.&nbsp;</li><li>Added an enhancement to display drive vendor and model name as separate fields in the Disk Information menu, improving clarity and ease of drive identification.&nbsp;</li><li>Added support to securely transfer encryption keys in remote key management mode.&nbsp;</li><li>Enhanced drive writes cache status reporting in HII.&nbsp;</li></ul>","Fixes":"<ul><li>Fixed an issue where SEDs reverting to foreign after controller reboot due to the otherwise owned flag not being saved to the datastore.&nbsp;</li><li>Fixed an issue where firmware crash/lockup during NDSR (Non-Disruptive Software Reset) due to a NULL pointer reference when handling a failed drive during logical drive rebuilt.&nbsp;</li><li>Fix 4Kn foreign SED being imported into a 512B logical drive due to incorrect failure handling, which could start a rebuild on an incompatible drive and ultimately fail.&nbsp;</li><li>Fixed an issue where multiple logical drives incorrectly showing REBUILDING simultaneously due to rebuild status not being updated properly during queued transformation and rebuild processes&nbsp;</li><li>Fixed an issue where master key change failure on Managed SED logical drives due to LU cache flush requests conflicting with the password update process.&nbsp;</li><li>Fixed an issue where physical drive Predictive Failure status not reported correctly by tools and iLO.&nbsp;</li><li>Fixed an issue where controller lockup during surface scan caused by stale internal resources when handling Unrecoverable Read Errors (UREs) in unmapped logical drive regions.&nbsp;</li><li>Fixed an issue where uncorrectable DDR ECC errors could be reported at boot due to cache being accessed before initialization.&nbsp;</li><li>Fixed an issue where the controller could lock up (0x3120C) when enabling MCP due to duplicate routing entries from flooded BMC requests.&nbsp;</li><li>Fixed an issue where SATA drives could be incorrectly reported as hot-removed during spin-up by adjusting the dampen timer to align with vendor-specified TTR values.&nbsp;</li><li>Fixed an issue where the controller could lock up (0x1E30) under high I/O workloads when configuration changes occurred simultaneously with a LUN reset.&nbsp;</li><li>Fixed an issue where RAID 0 could hang with I/O timeouts and LUN resets during Predictive Spare Rebuild.&nbsp;</li><li>Fixed an issue where the RAID controller could incorrectly report Online Firmware Activation as enabled. Firmware now checks support during PQI initialization and sets or clears the feature flags accordingly.&nbsp;</li><li>Fixed an issue where drives in some enclosures could show bay number 255 after the enclosure was powered on and hot-plugged, by adding handling for additional SCSI not ready status codes until the enclosure becomes ready.&nbsp;</li><li>Fixed an issue where Micron 6550 SED drives could fail to create a Secured Volume due to insufficient timeout during the TCG Revert process.&nbsp;</li><li>Fixed an issue where the controller Health state from PLDM PDRs could differ from the Storage.Status.HealthRollup value in RDE, by synchronizing the reporting logic.&nbsp;</li><li>Fixed an issue where SSD firmware updates could fail in dual path configurations due to PLDM errors, by sending Test Unit Ready commands to clear check conditions before SCSI passthrough operations.&nbsp;</li><li>Fixed an issue where Battery Redfish Alerts contained an incorrect OriginOfCondition pointing to a StorageController instead of the Battery resource.&nbsp;</li><li>Fixed an issue where RDE UPDATE operations on a Volume&rsquo;s ReadCachePolicy could incorrectly appear successful during a CBE rekey, by adjusting the cache update logic to return accurate results regardless of cache status.&nbsp;</li><li>Fixed an issue where the HotspareActivationPolicy allowable values incorrectly included OnDriveFailure for RAID 0 volumes with a dedicated spare, by adding configuration checks to ensure only valid values are shown.&nbsp;</li><li>Fixed an issue where there is a mismatch in Overall Health State and Logical Volume State during RPI, with sensors reporting Warning (Overall Health) while RDE READs ( Logical Volume State) showed OK; reporting OK during RPI is exxpected behavior.&nbsp;</li><li>Fixed an issue where ProtectedWriteBack could incorrectly appear as an allowable WriteCachePolicy in RDE READs even without a backup power source, by requiring the power source to be connected and fully charged before publishing the option.&nbsp;</li><li>Fixed an issue where an RDE READ on certain unsupported Drive resources could cause a controller lockup, by adding bounds checking in the firmware API.&nbsp;</li><li>Fixed an issue where deleting volumes through PLDM Type 6 could cause a controller lockup if other PLDM commands were sent simultaneously. These commands now return NOT_READY when a long-running RDE operation is in progress.&nbsp;</li><li>Fixed an issue where disk utilities could display an invalid box number for drives after failing over to an alternative path, by ensuring only valid controller-provided information is shown.&nbsp;</li><li>Fixed an issue where an incorrect error message was shown in HII when creating a logical drive on a locked SED, by updating the error message to correctly reflect SED encryption.&nbsp;</li></ul>","Lang":"cn"}],"Version":"7.81"},{"ReleaseNotes":[{"Enhancements":"<p>For Jan 2026</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>For Jan 2026</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>For Jan 2026</p>","Fixes":"","Lang":"cn"}],"Version":"8.00"}],"SWKeys":[{"Name":"03831590","SWKeyExpectedPath":"firmware"},{"Name":"03821590","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"1100103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"c1a1e73eca0649aba8389a70d7e7b502"}]},{"ProductId":"17203fd912204cbc96571639dbe02ea0","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、MB016000GWZHD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4156960","DateModified":"2025-11-17T08:37:20","FileList":["cp068733.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVANSTG1.rel"],"MD5Sum":"a40d99c2ae5f48c80895205cf08ab5db","Name":"cp068733.exe","Release":"2025-11-17T08:31:59","Revision":"F","SHA1Sum":"61b1db87c89a90c0f9feb0a020b7dd0ea0801f05","SHA256Sum":"ee6c61a61e9be69bf9651f9cf8b923af5c3e73f66ca98dc70eba832e0c8b91c4","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、およびMB016000GWZHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB010000GWZGT","TargetGUID":"4d2340a5-3042-3031-3030-3047575a4754","Type":"sata"},{"Id":"MB012000GWZGU","TargetGUID":"4d2340a5-3042-3231-3030-3047575a4755","Type":"sata"},{"Id":"MB014000GWZGV","TargetGUID":"4d2340a5-3042-3431-3030-3047575a4756","Type":"sata"},{"Id":"MB016000GWZHD","TargetGUID":"4d2340a5-3042-3631-3030-3047575a4844","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T05:08:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f4ad092bde7c4e34aa17c38fe542fafe"}]},{"ProductId":"e4dd84a160cc43f1b620391e92c1a737","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60およびKCM6FVUL3T20"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br />&nbsp;<strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK6</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK5</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK5</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br />&nbsp;<strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK6</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK5</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK5</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br />&nbsp;<strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK6</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK5</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK5</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6538701","DateModified":"2025-09-21T21:53:46","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/CP068925.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/KACM6ALFGPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068925.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068925.scexe"],"MD5Sum":"74f60454e721aa5028296b0b3319dc40","Name":"firmware-hdd-1a541ed00d-GPK6-4.1.x86_64.rpm","Release":"2025-09-22T02:43:36","Revision":"D","SHA1Sum":"595a0eb2302237a16f49dfbd798aeae8368ab6bf","SHA256Sum":"a75f21aca37d7f6a11a7d5b1d6c5086c82667593bf09f8b714ec4ff22f732b91","Size":"6MB","TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives"},{"Lang":"ja","Value":"オンラインNVMeSSDフラッシュコンポーネントfor Linux（x64）- KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60、およびKCM6FVUL3T20ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6FRUL1T92","TargetGUID":"002340a5-434b-364d-4652-554c31543932","Type":"nvme"},{"Id":"KCM6FRUL3T84","TargetGUID":"002340a5-434b-364d-4652-554c33543834","Type":"nvme"},{"Id":"KCM6FVUL3T20","TargetGUID":"002340a5-434b-364d-4656-554c33543230","Type":"nvme"},{"Id":"KCM6FVUL1T60","TargetGUID":"002340a5-434b-364d-4656-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:07:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>リセットの問題と定期的なメンテナンスファームウェアアップデートを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update</li></ul>","Lang":"cn"}],"Version":"GPK6"}],"SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f99825a1487a46a4b05ef9db9bb64e41"}]},{"ProductId":"486d4489346f4ec8a160ad4ef3c94f99","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"18069078","DateModified":"2025-06-14T08:32:26","FileList":["/CP067533_BUILD_2.data","/CP067533.vmexe64","/CP067533.vmfile","/CP067533_VMw.zip","/CP067533.xml","/payload.json","/CP067533_VMw.zip/index.xml","/CP067533_VMw.zip/vendor-index.xml","/CP067533_VMw.zip/metadata.zip","/CP067533_VMw.zip/vib20/CP067533/HPE_bootbank_CP067533_HPD9.2-8.0.0.20613240.vib","/CP067533_VMw.zip/metadata.zip/vendor-index.xml","/CP067533_VMw.zip/metadata.zip/vmware.xml","/CP067533_VMw.zip/metadata.zip/vibs/CP067533-6830835889799370995.xml","/CP067533_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067533_HPD9.2-8.0.0.20613240.xml"],"MD5Sum":"d5dc3c7f7cc790e0b50985b779108fbe","Name":"CP067533.zip","Release":"2025-06-14T08:31:37","Revision":"C","SHA1Sum":"8aada6ff94e8fae36f06c2c61d86ce757b20dacc","SHA256Sum":"d73b2798bb8aa00e99789a72943a2cb240a87973084afaca5581bc831940cd5d","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP067533","Version":"HPD9.2-8.0.0.20613240"}]}],"Installation":{"Command":"CP041673.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EH000900JWHPP","TargetGUID":"452340a5-3048-3030-3930-304a57485050","Type":"sas"},{"Id":"EH000600JWHPN","TargetGUID":"452340a5-3048-3030-3630-304a5748504e","Type":"sas"},{"Id":"EH000300JWHPL","TargetGUID":"452340a5-3048-3030-3330-304a5748504c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-11T02:49:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8ac70dfd510f496e8d1da7ee6c513ed2"}]},{"ProductId":"283d84a861d348648dca86da7b4218bd","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作するIntel i40ea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1246784","DateModified":"2025-11-16T10:04:12","FileList":["cp069537.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"1dc8375207d0e9120417d094dfe68d97","Name":"cp069537.exe","Release":"2025-11-16T09:50:34","Revision":"B","SHA1Sum":"933ec7f897ab6910bb896fc799f02838fa95e355","SHA256Sum":"7e6427ed762efc698272cfe07cfcc5900d43ae2c8166fa6bb3cbdf0d3dc9e804","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.22.88.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i40ea Driver for Windows Server 2022"},{"Lang":"ja","Value":"Intel i40eaドライバーfor Windows Server 2022"},{"Lang":"cn","Value":"Intel i40ea Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"cn"}],"Version":"1.22.88.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<ul><li>This product fixed the system event logging on Windows Server 2022.</li><li>This product fixed the BSOD during the RX queue initialization.</li></ul>","Lang":"cn"}],"Version":"1.22.88.0"}],"SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6b655bce70f34c5c82e7ea5b4d91807d"}]},{"ProductId":"b9a8e50fea15459f9f236f2538fb4a07","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains drivers for the HPE Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"cn","Value":"This component contains drivers for the HPE Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントは、HPE Broadcom NX1 1Gb Ethernetアダプターfor Microsoft Windows Server 2022およびWindows Server 2025を含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"979224","DateModified":"2025-11-17T02:10:16","FileList":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp069001.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"2849036ac3fa177d5bbe7bb2c13dfc03","Name":"cp069001.exe","Release":"2025-11-17T01:55:52","Revision":"C","SHA1Sum":"5f5c8c72579264524bb50849a13e858fbbd3fa17","SHA256Sum":"36f10bbb86569c647ae2c4adddad9f88e8d7cec69c5105a0dd99c0572d83e667","Size":"956KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"TypeOfChange":"1","Version":"221.0.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"cn","Value":"将 Smart Component 下载到硬盘目录中，然后转至该目录。<p>在该硬盘目录中，执行下载的文件。<p>点击“安装”按钮进行安装。"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"Lang":"cn","Value":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE Broadcom NX1 1Gbドライバーfor Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T03:19:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhances to update PNP ID table. (Plug and Play Identifier)</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、PNP IDテーブルのアップデートを強化します。(プラグアンドプレイ識別子)</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhances to update PNP ID table. (Plug and Play Identifier)</p>","Fixes":"","Lang":"cn"}],"Version":"221.0.8.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhances to update PNP ID table（Plug and Play Identifier）</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhances to update PNP ID table（Plug and Play Identifier）</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhances to update PNP ID table（Plug and Play Identifier）</p>","Fixes":"","Lang":"cn"}],"Version":"221.0.8.0"}],"SWKeys":[{"Name":"b57nd60a.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"87e159a8c516465fbacbe88e8ad509a5"}]},{"ProductId":"ff59337dd3ff4f44928eba3219e493a5","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3936-304b59445054","Version":"HPK6"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-304b59445055","Version":"HPK6"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3330-3834-304b59445056","Version":"HPK6"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3730-3638-304b59445141","Version":"HPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します: VK000960KYDPT、VK001920KYDPU、VK003840KYDPVおよびVK007680KYDQA"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This FW release modifies drive&#39;s behavior from &quot;returning error&quot; to &quot;silently discard&quot; if a request is received by drive from the host during FLR.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This FW release modifies drive&#39;s behavior from &quot;returning error&quot; to &quot;silently discard&quot; if a request is received by drive from the host during FLR.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This FW release modifies drive&#39;s behavior from &quot;returning error&quot; to &quot;silently discard&quot; if a request is received by drive from the host during FLR.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3169402","DateModified":"2025-11-21T05:54:22","FileList":["payload.json","Samsung_PM9A3_GPM9A3SAHPK6.HPb","Samsung_PM9A3_GPM9A3SAHPK6.xml"],"MD5Sum":"eeb605deb4ddfe514739ecece030179b","Name":"Samsung_PM9A3_GPM9A3SAHPK6.fwpkg","Release":"2025-11-21T05:51:14","Revision":"","SHA1Sum":"f7b2a4cdf23cca06910d78b2ebfc23a2ac5a8605","SHA256Sum":"08e9d14dd7cae0b3670db0bc83ba12f3fd2f40a407f363283e58e28ec672518a","Size":"3MB","TargetGUIDs":["562340a5-304b-3030-3936-304b59445054","562340a5-304b-3130-3932-304b59445055","562340a5-304b-3330-3834-304b59445056","562340a5-304b-3730-3638-304b59445141"],"TypeOfChange":"1","Version":"HPK6"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - VK000960KYDPT、VK001920KYDPU、VK003840KYDPV、VK007680KYDQA"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VK000960KYDPT","TargetGUID":"562340a5-304b-3030-3936-304b59445054","Type":"nvme"},{"Id":"VK001920KYDPU","TargetGUID":"562340a5-304b-3130-3932-304b59445055","Type":"nvme"},{"Id":"VK003840KYDPV","TargetGUID":"562340a5-304b-3330-3834-304b59445056","Type":"nvme"},{"Id":"VK007680KYDQA","TargetGUID":"562340a5-304b-3730-3638-304b59445141","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-18T07:55:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This FW update contains the fix for false ILO message of temporary drive &quot;degraded&quot; status.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWアップデートには、ドライブの一時的な\"劣化\"ステータスに関する誤ったILOメッセージの修正が含まれています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This FW update contains the fix for false ILO message of temporary drive &quot;degraded&quot; status.</li></ul>","Lang":"cn"}],"Version":"HPK5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This FW release modifies drive&#39;s behavior from &quot;returning error&quot; to &quot;silently discard&quot; if a request is received by drive from the host during FLR.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This FW release modifies drive&#39;s behavior from &quot;returning error&quot; to &quot;silently discard&quot; if a request is received by drive from the host during FLR.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This FW release modifies drive&#39;s behavior from &quot;returning error&quot; to &quot;silently discard&quot; if a request is received by drive from the host during FLR.</li></ul>","Lang":"cn"}],"Version":"HPK6"}],"SWKeys":[{"Name":"VK000960KYDPT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK001920KYDPU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK003840KYDPV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK007680KYDQA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"46c24384109040aea7a6064e47696122"}]},{"ProductId":"aa62b707fef04bb99492053e558daffb","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB016000JWXKH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5870424","DateModified":"2025-09-17T12:59:42","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/CP068858.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/TAMG08scHPDC.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068858.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068858.scexe"],"MD5Sum":"6dfc83de2d4323542b4615859b52f276","Name":"firmware-hdd-8a0371a425-HPDC-3.1.x86_64.rpm","Release":"2025-09-17T17:48:05","Revision":"C","SHA1Sum":"1743ea6b0661b9e243936f4bab2c016bec404da3","SHA256Sum":"5b6e7f65ec68723ca9bf31054ebc2e54ec01f5d1440f1991a826ad9d6efe92e4","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JWXKH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB016000JWXKHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB016000JWXKH","TargetGUID":"4d2340a5-3042-3631-3030-304a57584b48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:58:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDC"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDC"}],"SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"32c19a99dc72438aa00618642c71a953"}]},{"ProductId":"cca7377cd12644cab41f5bd7e94cc2bd","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8002-MCX653105A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30069","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor HPE InfiniBand HDR/Ethernet 100Gb 1ポートQSFP56 PCIe4 x16 MCX653105A-ECATアダプター: HPE部品番号P23665-B21およびP23665-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p><strong>HDR / 200GbE cables:</strong></p><ul><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><ul></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p><strong>HDR / 200GbEケーブル：</strong></p><ul><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p><strong>HDR / 200GbE cables:</strong></p><ul><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><ul></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6276366","DateModified":"2025-10-08T10:15:21","FileList":["20_43_8002-MCX653105A-ECA_HPE_Ax.pldm.signed","20_43_8002-MCX653105A-ECA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"cb930daa6dc964e16748a233c772868f","Name":"20_43_8002-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","Release":"2025-10-08T10:13:04","Revision":"","SHA1Sum":"8399b893b4d89ecba676ebee5093f3da882732f7","SHA256Sum":"b13cf4b8865700e2a598ba4d0e99ab7df7755201c022049e798951f172e9e792","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"TypeOfChange":"1","Version":"20.43.8002"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ（FWPKG）for HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe4 x16 MCX653105A-ECATアダプター: HPE部品番号P23665-B21およびP23665-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-08T06:57:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"20.43.8002"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653105A-ECAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"a9a7a4d74eaf4a169b6449cbfb4219fd"}]},{"ProductId":"01713b1febed4cc9a463023eeb2cf6ee","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPP、およびMK001920GWJPQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"3074656","DateModified":"2025-11-18T02:33:14","FileList":["4IYVHPG5.rel","cp068621.xml","cpqsetup.exe","payload.json","setup.dll"],"MD5Sum":"e7623795a0869509266609f47505890f","Name":"cp068621.exe","Release":"2025-11-18T02:28:16","Revision":"I","SHA1Sum":"38a1c5c19ec14ce1171cc081a078a9d7e37aa4eb","SHA256Sum":"fcfc2072131aeefdfd8b13eac286e360314b445aae1d40444952aa81428f0e0b","Size":"2MB","TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MK001920GWJPQ","TargetGUID":"4d2340a5-304b-3130-3932-3047574a5051","Type":"sata"},{"Id":"VK001920GWJPH","TargetGUID":"562340a5-304b-3130-3932-3047574a5048","Type":"sata"},{"Id":"MK000240GWKVK","TargetGUID":"4d2340a5-304b-3030-3234-3047574b564b","Type":"sata"},{"Id":"VK000240GWJPD","TargetGUID":"562340a5-304b-3030-3234-3047574a5044","Type":"sata"},{"Id":"VK003840GWJPK","TargetGUID":"562340a5-304b-3330-3834-3047574a504b","Type":"sata"},{"Id":"MK000480GWJPN","TargetGUID":"4d2340a5-304b-3030-3438-3047574a504e","Type":"sata"},{"Id":"VK000480GWJPE","TargetGUID":"562340a5-304b-3030-3438-3047574a5045","Type":"sata"},{"Id":"MK000960GWJPP","TargetGUID":"4d2340a5-304b-3030-3936-3047574a5050","Type":"sata"},{"Id":"VK000960GWJPF","TargetGUID":"562340a5-304b-3030-3936-3047574a5046","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T07:22:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"97f9bd5cfe0948f8812fc1eb5af3e9c3"}]},{"ProductId":"4de9a363a422456faca983d193ca352a","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.62 (01/09/2026)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33612809","DateModified":"2026-01-14T03:24:10","FileList":["payload.json","U31_3.62_01_09_2026.signed.flash","U31_3.62_01_09_2026.xml"],"MD5Sum":"3e91b2d5234fcb0c781b9b7fadc3b553","Name":"U31_3.62_01_09_2026.fwpkg","Release":"2026-01-14T03:20:09","Revision":"","SHA1Sum":"4066386ed9f2de838d7af744955ca47b8576f0db","SHA256Sum":"5aea9db78c41b196d2f99542094a5c65ac79006f6d8e565fcbec127bb1efcee4","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T02:28:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"bbacaed717884551acb7bedfe36c0270"}]},{"ProductId":"03d55b6f216746b88ddef311b0a8c1f9","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.27"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 8.0 and vSphere 9.0"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 8.0 and vSphere 9.0"},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 8.0 and vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12763136","DateModified":"2025-03-07T08:18:12","FileList":["/CP064334_BUILD_14.data","/CP064334.vmexe64","/CP064334.vmfile","/CP064334_VMw.zip","/CP064334.xml","/payload.json","/CP064334_VMw.zip/index.xml","/CP064334_VMw.zip/vendor-index.xml","/CP064334_VMw.zip/metadata.zip","/CP064334_VMw.zip/vib20/CP064334/HPE_bootbank_CP064334_1.37.0.14-1OEM.900.0.24580437.vib","/CP064334_VMw.zip/metadata.zip/vendor-index.xml","/CP064334_VMw.zip/metadata.zip/vmware.xml","/CP064334_VMw.zip/metadata.zip/vibs/CP064334-5298665747733123646.xml","/CP064334_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064334_1.37.0.14-1OEM.900.0.24580437.xml"],"MD5Sum":"e5abc6b3607593ece897452d5d098bd1","Name":"CP064334.zip","Release":"2025-03-07T08:17:32","Revision":"","SHA1Sum":"cded85e6bf9048ea23ebc47b27e172b06946b2af","SHA256Sum":"d2f9a158a9dbe67e7fda9590b853fcfd2013675b81f3a48b12f6c421bb460643","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"1.37.0","VibList":[{"Name":"CP064334","Version":"1.37.0.14-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","DeviceGUID":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E3-Ethernet-iSCSI-FCoE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.0.251.0-1OEM.700.1.0.15843807"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","SWKey":"qfle3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.4.51.0-1OEM.700.1.0.15843807"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Manual installation instructions:</strong></p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>For ESXi 7.0 targets: esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>For ESXi 6.x targets: esxcli software vib install -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install -d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>Clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>For ESXi 7.0 targets: esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>For ESXi 6.x targets: esxcli software vib remove -n CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>手動によるインストール手順：</strong></p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>ESXi 7.0ターゲットの場合：esxcli  software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li><li>ESXi 6.xターゲットの場合：esxcli software vib install -d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します：./Execute_Component -s</li></ul></li><li>Smartコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>ESXi 7.0ターゲットの場合：esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>ESXi 6.xターゲットの場合：esxcli software vib remove -n CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Manual installation instructions:</strong></p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>For ESXi 7.0 targets: esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>For ESXi 6.x targets: esxcli software vib install -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install -d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>Clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>For ESXi 7.0 targets: esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>For ESXi 6.x targets: esxcli software vib remove -n CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 Online Firmware Upgrade Utility for VMware"},{"Lang":"cn","Value":"VMware版HPE QLogic NX2在线固件升级实用程序"},{"Lang":"ja","Value":"HPE QLogic NX2オンライン ファームウェアアップグレードユーティリティ for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T03:49:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.35.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.37.0"}],"SWKeys":[{"Name":"QLOGIC_NX2","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bd85de99f5db486e935b9e5b89d776e7"}]},{"ProductId":"c94878ce1a3442eca368e62460770912","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 10 Update 0."},{"Lang":"ja","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 10 Update 0."},{"Lang":"cn","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 10 Update 0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"45648","DateModified":"2025-12-12T07:02:56","FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/7f","./usr/lib/.build-id/7f/bd5fe78c5acc0aa4f13038179b97747eea69d7","./usr/lib64/libbnxt_re-235.1.164.14.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"MD5Sum":"94af9e59b8d02cf82d1239c119bc263a","Name":"libbnxt_re-235.1.164.14-rhel10u0.x86_64.rpm","Release":"2025-12-12T07:01:05","Revision":"","SHA1Sum":"b1156d0deac1120886d9fd0ec0909e8d3e642a11","SHA256Sum":"4a382611c8607eca2ccf23073f755bc123ecf315462831b022ae0c20e797c4e5","Size":"44KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"ja","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"cn","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 0."},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 0."},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 0."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-12T04:04:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a4baff443cfe4f1fb1bd88340daf8418"}]},{"ProductId":"644b370c36714c6490fce699ffce22e9","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U37_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33607982","DateModified":"2026-01-12T06:57:04","FileList":["payload.json","U37_3.62_01_09_2026.signed.flash","U37_3.62_01_09_2026.xml"],"MD5Sum":"ed8be4522789a9859fd03e87d4826bd9","Name":"U37_3.62_01_09_2026.fwpkg","Release":"2026-01-12T06:53:47","Revision":"","SHA1Sum":"163d2eaa76ee3e9a1a7ff1df965dca971de8bdcc","SHA256Sum":"ab96e2134020afa8f319fc3991d00ac78788892f4f20daeb533b44f273c2ec8f","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:41:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"bb7dac35a0864d96aad69f3db362161f"}]},{"ProductId":"5588a72e9c0d4878a499b54f0c18241c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The HPE ESXi Agentless Management Smart Component for ESXi includes the latest HPE Agentless Management Service (AMS)."},{"Lang":"ja","Value":"HPE ESXi Agentless Management Smartコンポーネントfor ESXiには、最新のHPE Agentless Management Service（AMS）が含まれています。"},{"Lang":"cn","Value":"The HPE ESXi Agentless Management Smart Component for ESXi includes the latest HPE Agentless Management Service (AMS)."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7182988","DateModified":"2025-12-05T13:14:00","FileList":["/cp069193.xml","/amsdComponent_802.11.12.0.4-1-signed_component.zip","/amsdComponent_802.11.12.0.4-1-signed_component.zip/index.xml","/amsdComponent_802.11.12.0.4-1-signed_component.zip/vendor-index.xml","/amsdComponent_802.11.12.0.4-1-signed_component.zip/metadata.zip","/amsdComponent_802.11.12.0.4-1-signed_component.zip/vib20/amsd/HPE_bootbank_amsd_802.11.12.0.4-1OEM.802.0.0.22380479.vib","/amsdComponent_802.11.12.0.4-1-signed_component.zip/metadata.zip/vendor-index.xml","/amsdComponent_802.11.12.0.4-1-signed_component.zip/metadata.zip/vmware.xml","/amsdComponent_802.11.12.0.4-1-signed_component.zip/metadata.zip/vibs/amsd-1472299603547755996.xml","/amsdComponent_802.11.12.0.4-1-signed_component.zip/metadata.zip/bulletins/amsdComponent_802.11.12.0.4-1.xml"],"MD5Sum":"c6b1d598f736bfdfc8b73a61469d10f9","Name":"cp069193.zip","Release":"2025-12-05T13:13:48","Revision":"","SHA1Sum":"2df441c4e7dd79e544fafecc44397726411fb315","SHA256Sum":"5828981f4361feefd3bcd76dbb6c8124d00e09f679034b9ab8d8cbc79a3d1222","Size":"6MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.2"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e6a28ab"],"TypeOfChange":"1","Version":"2025.11.01","VibList":[{"Name":"amsd","Version":"802.11.12.0.4-1OEM.802.0.0.22380479"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":200,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the smart component zip file to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip the&nbsp;HPE smart&nbsp;component zip file to extract the driver offline bundle&nbsp;zip file.</li><li>Copy the driver offline bundle zip file extracted in the previous step&nbsp;to the VMware host server.</li><li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li></ul>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用して、このバンドルをオンラインでリモートインストールするには：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにsmartコンポーネントzipファイルを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li><li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってアップデートを行います。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p><ul><li>ドライバーオフラインバンドルのzipファイルを抽出するために、HPE Smartコンポーネントのzipファイルを解凍します。</li><li>前の手順で抽出したドライバーオフラインバンドルのzipファイルをVMwareホストサーバーにコピーします。</li><li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li><li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li></ul>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the smart component zip file to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip the&nbsp;HPE smart&nbsp;component zip file to extract the driver offline bundle&nbsp;zip file.</li><li>Copy the driver offline bundle zip file extracted in the previous step&nbsp;to the VMware host server.</li><li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Agentless Management Bundle Smart Component on ESXi for Gen10 and Gen10 Plus Servers"},{"Lang":"ja","Value":"HPE Agentless ManagementバンドルSmartコンポーネントon ESXi for Gen10およびGen10 Plusサーバー"},{"Lang":"cn","Value":"HPE Agentless Management Bundle Smart Component on ESXi for Gen10 and Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"700"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-11-16T17:23:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"2025.05.01"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"2025.11.01"}],"SWKeys":[{"Name":"amsdComponent:802.11.12.0.4-1-signed_component","SWKeyExpectedPath":"software.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U65","Model":"HPE MicroServer Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1fa5308a64884136b0383a530f371780"}]},{"ProductId":"c1dd5be659f944a486917246089b40e7","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1537FFFF0000","Version":"1.2877"},{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-153700000000","Version":"1.2877"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline System running a supported Linux Operating System installed in HPE Edgeline EL8000/EL8000t chassis."},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Edgeline EL8000/EL8000tシャーシに設置されたサポート対象のLinuxオペレーティングシステムを実行するHPE Edgelineシステムに直接インストールできるNICファームウェアを提供します。"},{"Lang":"cn","Value":"This smart component provides NIC firmware that can be installed directly on HPE Edgeline System running a supported Linux Operating System installed in HPE Edgeline EL8000/EL8000t chassis."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9346144","DateModified":"2026-01-23T09:01:07","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1/CP057771.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1/bootutil64e","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1/ilorest_chif.so","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP057771.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP057771.scexe"],"MD5Sum":"509ba0a3bf989aef6f645fe8d44320e6","Name":"firmware-nic-i210-nic-1.2877-2.1.x86_64.rpm","Release":"2026-01-23T14:48:35","Revision":"B","SHA1Sum":"847a1702423fa58f824c8718b84c2d4dca196b9b","SHA256Sum":"dc00d68a5697fd491e5245e7c3dbcbde40877b8d599fcf3128d6d6b6538acf20","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-1537FFFF0000","a6b1a447-382a-5a4f-8086-153700000000"],"TypeOfChange":"1","Version":"1.2877"}],"Installation":{"Command":"setup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;&nbsp; &nbsp;<br /><strong>To install firmware from Linux operating system on target server:</strong></p><p>&nbsp;</p><p>Execute the below commands:</p><p>&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change(cd) to the directory you see in the previous step and run hpsetup by typing &lsquo;./setup&rsquo; at the command prompt.</p><p><strong>Note</strong>: Installing the firmware rpm package (rpm -ivh) does not update the firmware. &nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed using SUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"},{"Lang":"ja","Value":"<p>    <br /><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをインストールするには、以下の手順に従ってください：</strong></p><p> </p><p>以下のコマンドを実行します：</p><p>>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前の手順で確認したディレクトリに移動し（cd）、コマンドプロンプトに‘./setup’と入力してhpsetupを実行します。</p><p><strong>注記：</strong>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。 単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p> </p><p><strong>Service Pack for EdgelineからSmart Update Managerを使用してファームウェアをインストールするには、次の手順に従います：</strong></p><p> </p><p>このSmartコンポーネントは、Service Pack for Edgeline（SPE）でも利用可能であり、SUMを使用してインストールできます</p><p> </p><p>インストール手順についてはSUMユーザーガイドを、詳細についてはSPEリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p>&nbsp;&nbsp; &nbsp;<br /><strong>To install firmware from Linux operating system on target server:</strong></p><p>&nbsp;</p><p>Execute the below commands:</p><p>&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change(cd) to the directory you see in the previous step and run hpsetup by typing &lsquo;./setup&rsquo; at the command prompt.</p><p><strong>Note</strong>: Installing the firmware rpm package (rpm -ivh) does not update the firmware. &nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p><p>&nbsp;</p><p><strong>To install firmware using Smart Update Manager from Service Pack for Edgeline:</strong></p><p>&nbsp;</p><p>This Smart Component is also available in Service Pack for Edgeline(SPE) and can be installed using SUM</p><p>&nbsp;</p><p>Please refer to SUM user guide for installation instructions and SPE Release Notes for more details.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Edgeline i210 NIC Firmware Component for Linux"},{"Lang":"ja","Value":"HPE Edgeline i210 NICファームウェアコンポーネントfor Linux"},{"Lang":"cn","Value":"HPE Edgeline i210 NIC Firmware Component for Linux"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"9000"},"SupportedDevices":[{"Dev":"1537","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153700000000","Type":"pci","Ven":"8086"},{"Dev":"1537","SubDev":"0000","SubVen":"FFFF","TargetGUID":"a6b1a447-382a-5a4f-8086-1537FFFF0000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-07-28T07:19:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"1.2877"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Updated with XD220 and XD295 nodes</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Updated with XD220 and XD295 nodes</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Updated with XD220 and XD295 nodes</p>","Lang":"cn"}],"Version":"1.2877"}],"SWKeys":[{"Name":"i210_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD665"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fca448f909e941b281ceb598e7fbc8e7"}]},{"ProductId":"2ea9059fa42b417a890b2c9927375976","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーは、オペレーティングシステムがロックアップした場合にサーバーをリセットするASRハードウェアタイマーを管理します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"603608","DateModified":"2025-11-18T03:32:18","FileList":["cp069726.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"MD5Sum":"90e0e5e7fe1c9ec506633dec28bf858d","Name":"cp069726.exe","Release":"2025-11-18T03:29:57","Revision":"D","SHA1Sum":"7bea197f62d9237ad3698c56654b63ff50f8f820","SHA256Sum":"02d38376c18d1911600c94d899e1bf0e79e6235b53ad5c906374ca7f1fdcf315","Size":"589KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.2.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーfor Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T03:28:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.2.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.2.0"}],"SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\nechesasr.inf_amd64_4549a532e2f9c151"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"154a444b0711470cab8f62e39aab2ac8"}]},{"ProductId":"624ecf606d7d4d2c94cae219a5491b9e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"854256","DateModified":"2025-11-16T02:59:21","FileList":["cp069558.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs.cat","vxs.inf","vxs.sys","vxsmsg.dll"],"MD5Sum":"3da51b596dd6c8e2ba32e67e0c9445cb","Name":"cp069558.exe","Release":"2025-11-16T02:44:54","Revision":"C","SHA1Sum":"9e9cb0b6e8f0791f5c96ae99576a914286677694","SHA256Sum":"ee3e4e76d38e2dd111f6b9e111785d369d4b752132d1c335469451c013a5f18f","Size":"834KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"TypeOfChange":"1","Version":"2.3.2.4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel vxs Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Intel vxsドライバーfor Windows Server 2025"},{"Lang":"cn","Value":"HPE Intel vxs Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1565","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d1","Type":"pci","Ven":"8086"},{"Dev":"1564","Type":"pci","Ven":"8086"},{"Dev":"1565","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d2","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"cn"}],"Version":"2.3.2.4"},{"ReleaseNotes":[{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product added E610 VF device ID.</p>","Fixes":"","Lang":"cn"}],"Version":"2.3.2.4"}],"SWKeys":[{"Name":"vxs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\vxs.inf_amd64_d6120d6ae1cc028c"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1b5e6b3378d6409db3052ab56c33f4bc"}]},{"ProductId":"6f77f9ef4381482fb9f00a79ce325ab3","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A40_3.70_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.70 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33599342","DateModified":"2026-01-14T07:55:21","FileList":["A40_3.70_01_09_2026.signed.flash","A40_3.70_01_09_2026.xml","payload.json"],"MD5Sum":"989b896d0840bf8f7eaf04cd70553d55","Name":"A40_3.70_01_09_2026.fwpkg","Release":"2026-01-14T07:51:27","Revision":"","SHA1Sum":"a4f1e5b6a56bde7717b8c45ababcb5e8833b56c9","SHA256Sum":"238861f82d0becabb99d6204e83f73fd8ea395e9fb5383a5e963eb14cb02db71","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"1","Version":"3.70_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL385 Gen10 (A40) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL385 Gen10（A40）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL385 Gen10 (A40) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T10:46:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>CVE-2025-3052を軽減するために、デフォルトのセキュアブートDBXをアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。システムROMのこのリビジョンには、AMD第1世代EPYCプロセッサー用のAMDリファレンスコードNaplesPI 1.0.0.Rが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Redfish経由でのBIOS設定の変更が、同じ起動中にBIOSアップデートが実行された場合に、失敗するという問題に対処しました。</p><p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_09-05-2025"},{"ReleaseNotes":[{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.70_01-09-2026"}],"SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"1ed83aa415d449a2baa8b55ddc25ad32"}]},{"ProductId":"3d8cb748df644cf3a26ed91efafffb67","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"Lang":"ja","Value":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10およびGen11コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされるバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と機能強化を入手するため、インストールする必要があります。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>Removed HPE Smart Array P204i-b, P408e-m, P408i-sb SR Gen10 from supported device lists.</p>"},{"Lang":"ja","Value":"<p>サポートされているデバイスリストからHPE SmartアレイP204i-b、P408e-m、P408i-sb SR Gen10が削除されました。</p>"},{"Lang":"cn","Value":"<p>Removed HPE Smart Array P204i-b, P408e-m, P408i-sb SR Gen10 from supported device lists.</p>"}],"Files":[{"Bytes":"107784","DateModified":"2025-12-05T02:37:04","FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/smartpqi","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/e0","./usr/lib/.build-id/e0/5a80d7245b82932e74e895adc56610bc77e83c","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"MD5Sum":"0e06a435b6b4760f50a4bd636070de73","Name":"kmod-smartpqi-2.1.38-022.rhel9u6.x86_64.rpm","Release":"2025-12-05T02:32:39","Revision":"","SHA1Sum":"cd88764f1ef11e63d200aea743be1ea2e931832b","SHA256Sum":"c1526e53cca3ea76f8069b65eee5479526dc7fb68e324c88c845152ba389eae9","Size":"105KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.38-022"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp; <strong>-</strong>-oldpackage --replacefiles --replacepkgs<strong>&nbsp;</strong>kmod-smartpqi-&lt;version&gt;.rhel9&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li></ul><p>&nbsp;</p><p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e kmod-smartpqi-&lt;version&gt;.rhel9&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array&nbsp;controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>システム管理者（root）としてログインし、RPMを<br />ご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p><p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p><p> </p><ul><li># rpm -Uvh  <strong>-</strong>-oldpackage --replacefiles --replacepkgs<strong> </strong>kmod-smartpqi-<version>.rhel9<OSupdate>.x86_64.rpm  </li></ul><p> </p><p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>注記</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p><ul><li># rpm -e kmod-smartpqi-<version>.rhel9<OSupdate>.x86_64.rpm</li></ul><p><strong><u>エンタープライズサポート</u></strong><br />Smartアレイコントローラーのサポートに関しては <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp; <strong>-</strong>-oldpackage --replacefiles --replacepkgs<strong>&nbsp;</strong>kmod-smartpqi-&lt;version&gt;.rhel9&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li></ul><p>&nbsp;</p><p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e kmod-smartpqi-&lt;version&gt;.rhel9&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array&nbsp;controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 9 (64-bit)"},{"Lang":"ja","Value":"HPE ProLiant Gen10、Gen10Plus、およびGen11 Smartアレイコントローラー（64ビット）ドライバーfor Red Hat Enterprise Linux 9 (64ビット)"},{"Lang":"cn","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 9 (64-bit)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T09:39:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added a timeout value to RAID path requests to physical devices.</li></ul>","Fixes":"<ul><li>Fixed an issue where the kernel call trace when calling smp_processor_id() in real-time kernel.&nbsp;</li><li>Fixed an issue of accessing NULL SCSI device pointer caused by a rare race condition.&nbsp;</li><li>Fixed a system crash issue caused by a divide-by-zero condition.&nbsp;</li><li>Fixed an issue where after a device has been removed, it&#39;s possible for a previously scheduled work item for a LUN reset to be executed.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added a timeout value to RAID path requests to physical devices.</li></ul>","Fixes":"<ul><li>リアルタイムカーネルでsmp_processor_id()を呼び出すときにカーネル呼び出しトレースが実行される問題を修正しました。 </li><li>まれな競合状態によって発生するNULL SCSIデバイスポインターへのアクセスの問題を修正しました。 </li><li>ゼロ除算条件によって発生するシステムクラッシュの問題を修正しました。 </li><li>デバイスが削除された後、以前にスケジュールされた LUNリセットの作業項目が実行される可能性がある問題を修正しました。 </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added a timeout value to RAID path requests to physical devices.</li></ul>","Fixes":"<ul><li>Fixed an issue where the kernel call trace when calling smp_processor_id() in real-time kernel.&nbsp;</li><li>Fixed an issue of accessing NULL SCSI device pointer caused by a rare race condition.&nbsp;</li><li>Fixed a system crash issue caused by a divide-by-zero condition.&nbsp;</li><li>Fixed an issue where after a device has been removed, it&#39;s possible for a previously scheduled work item for a LUN reset to be executed.&nbsp;</li></ul>","Lang":"cn"}],"Version":"2.1.36-026"},{"ReleaseNotes":[{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2.1.38-022"}],"SWKeys":[{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3ba8955d2eee4602a11446ec07e9a45c"}]},{"ProductId":"7a201554eb654a4fa5bf0b9e23666148","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57416 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957416N4160HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41592","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957416N4160HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957416N4160HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Version":"235.1.164.14"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57416 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57416 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57416 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"1602361","DateModified":"2025-12-11T09:34:16","FileList":["BCM235.1.164.14_BCM957416N4160HC.HPb","BCM235.1.164.14_BCM957416N4160HC.xml","payload.json"],"MD5Sum":"27f1a7e3145fcdfd8a560d4be51be82d","Name":"BCM235.1.164.14_BCM957416N4160HC.fwpkg","Release":"2025-12-11T09:31:20","Revision":"","SHA1Sum":"0de8f535b87dc8b504cc7d68835b94268f8ef6d1","SHA256Sum":"52c00832388fa7ac319fbe4abcbc7adc03e8f593b0f0f688f6efec3605d2e2b9","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41592"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM57416 OCP3 adapter"},{"Lang":"ja","Value":"Broadcom Firmware Package for BCM57416 OCP3 adapter"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM57416 OCP3 adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-11T08:08:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"BCM_NXE_57416OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"7e79add644b5423b8f41566c6afb0364"}]},{"ProductId":"15c5494e659e4865b78e60077bae7860","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXF"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXF"},{"Lang":"cn","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features:&nbsp;</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features:&nbsp;</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features:&nbsp;</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"}],"Files":[{"Bytes":"5812520","DateModified":"2025-11-15T18:52:14","FileList":["85032G00_mp.bin","cp068635.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"22e7185ec4b5605633b6f93733aaa54e","Name":"cp068635.exe","Release":"2025-11-15T18:46:03","Revision":"H","SHA1Sum":"67c0aa3a220eb6be0a1c8147f0241eb7bd03bd71","SHA256Sum":"63890f44054a00c797e7601b60fb5d74bd72a4e5bdf90408ef3adad7ae14d8b8","Size":"5MB","TargetGUIDs":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3330-3834-304b57584651"],"TypeOfChange":"1","Version":"85032G00"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the&nbsp;</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em>&nbsp;script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the&nbsp;</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em>&nbsp;script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VS000480KXALB","TargetGUID":"562340a5-3053-3030-3438-304b58414c42","Type":"nvme"},{"Id":"VS003840KWXFQ","TargetGUID":"562340a5-3053-3330-3834-304b57584651","Type":"nvme"},{"Id":"VS001920KWXFP","TargetGUID":"562340a5-3053-3130-3932-304b57584650","Type":"nvme"},{"Id":"VS000960KWXFN","TargetGUID":"562340a5-3053-3030-3936-304b5758464e","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T08:49:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>特定のシナリオでドライブがコントローラーの背後にある場合のドライブフラッシュの問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul>","Lang":"cn"}],"Version":"85032G00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul>","Lang":"cn"}],"Version":"85032G00"}],"SWKeys":[{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2209d7eaa57a4b1d8bc62287415a7ba6"}]},{"ProductId":"fcbfe734454648628f4d8c3848d7db3e","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALFHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058565255","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALFHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058565252","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALFHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058565254","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します：MO001600PXVRU、VO003840PXVRRおよびVO007680PXVRT"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;To fix chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;To fix chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;To fix chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1659531","DateModified":"2025-07-03T14:53:22","FileList":["Kioxia_PM7_KAPM7ALFHPD3.HPb","Kioxia_PM7_KAPM7ALFHPD3.xml","payload.json"],"MD5Sum":"3c136a6b78141539f7d5a7d886283191","Name":"Kioxia_PM7_KAPM7ALFHPD3.fwpkg","Release":"2025-07-03T14:50:34","Revision":"","SHA1Sum":"a623f578c663db154b05fc1512812ac47370b13f","SHA256Sum":"85216452bb60f9c10acbdddcad11748f412dbcbd90db437482b591d1deb573b3","Size":"1MB","TargetGUIDs":["4d2340a5-304f-3130-3630-305058565255","562340a5-304f-3330-3834-305058565252","562340a5-304f-3730-3638-305058565254"],"TypeOfChange":"2","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO001600PXVRU、VO003840PXVRRおよびVO007680PXVRT"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO007680PXVRT","TargetGUID":"562340a5-304f-3730-3638-305058565254","Type":"sas"},{"Id":"VO003840PXVRR","TargetGUID":"562340a5-304f-3330-3834-305058565252","Type":"sas"},{"Id":"MO001600PXVRU","TargetGUID":"4d2340a5-304f-3130-3630-305058565255","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-02T01:58:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li><li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us\" id=\"menur2cjc\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00146367en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us</a> which will be active on 20-Mar-2025.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブヘルスのクエリが誤ったドライブ予測エラーを引き起こす可能性がある稀なケースに対処するための修正を追加しました。</li><li>詳しくは、HPEカスタマーアドバイザリ：<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us\" id=\"menur2cjc\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00146367en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us</a> (2025年3月20日から有効) を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li><li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us\" id=\"menur2cjc\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00146367en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us</a> which will be active on 20-Mar-2025.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>To fix chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>To fix chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>To fix chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MO001600PXVRU","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PXVRR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PXVRT","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"cfb3c1b576564b7fafa4c9bdcc52cffb"}]},{"ProductId":"33179a0f0a644a26bd07818fb3f2db4e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6792777","DateModified":"2025-09-21T21:12:18","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/CP068918.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/HPG1_PM893.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068918.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068918.scexe"],"MD5Sum":"44b7368b565838977a3383e9d065ea55","Name":"firmware-hdd-abd133f0de-HPG1-6.1.x86_64.rpm","Release":"2025-09-22T02:02:48","Revision":"F","SHA1Sum":"0780dd7bd4216ae12774d98d540f9e63e2c868d2","SHA256Sum":"5e601cfa863906f9685ef674999da38fda075053284c6743534631d9efb7af4d","Size":"6MB","TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040346.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK001920GZXQV","TargetGUID":"562340a5-304b-3130-3932-30475a585156","Type":"sata"},{"Id":"VK003840GZXRH","TargetGUID":"562340a5-304b-3330-3834-30475a585248","Type":"sata"},{"Id":"VK007680GZXRT","TargetGUID":"562340a5-304b-3730-3638-30475a585254","Type":"sata"},{"Id":"VK000960GZXQU","TargetGUID":"562340a5-304b-3030-3936-30475a585155","Type":"sata"},{"Id":"VK000480GZXRF","TargetGUID":"562340a5-304b-3030-3438-30475a585246","Type":"sata"},{"Id":"VK000240GZXRU","TargetGUID":"562340a5-304b-3030-3234-30475a585255","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:59:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bdb052e5bc314474ac40768eebf83bce"}]},{"ProductId":"a162b7594d8d4a02bf2f3f7d9fe2609d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel NICs Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release igb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished&nbsp;(This generic binary RPM is the same with hp-igb-kmp-default version 6.14.16）<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-igb-kmp-default) to (igb-kmp-default). Now we revert this change from (igb-kmp-default) to (<strong>hp</strong>-igb-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-igb-kmp-default and igb-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install igb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e igb-kmp-default and then install the updated RPM.<br />&nbsp;&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースigb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません (この汎用バイナリRPMはhp-igb-kmp-defaultバージョン6.14.16と同じです)<br />    - RPMパッケージ名は（<strong>hp</strong>-igb-kmp-default）から（igb-kmp-default）に変更されました。この変更を（igb-kmp-default）から（<strong>hp</strong>-igb-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-igb-kmp-defaultとigb-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにigb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e igb-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。<br />  </p>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release igb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished&nbsp;(This generic binary RPM is the same with hp-igb-kmp-default version 6.14.16）<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-igb-kmp-default) to (igb-kmp-default). Now we revert this change from (igb-kmp-default) to (<strong>hp</strong>-igb-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-igb-kmp-default and igb-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install igb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e igb-kmp-default and then install the updated RPM.<br />&nbsp;&nbsp;</p>"}],"Files":[{"Bytes":"180115","DateModified":"2025-09-16T08:31:53","FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-igb","./lib/modules/6.4.0-150600.21-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"MD5Sum":"926e7b6af43693a78cf96b2795230f34","Name":"hp-igb-kmp-default-6.19.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-09-16T08:24:58","Revision":"","SHA1Sum":"8aeb1cbb44690e68768124d091ef878268d34175","SHA256Sum":"2d43a16344393bdeee9874517b4b8f960c504a37d7938687f92b2c48eab33972","Size":"175KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"TypeOfChange":"1","Version":"6.19.4-1"},{"Bytes":"179351","DateModified":"2025-09-16T08:36:08","FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-igb","./lib/modules/6.4.0-150700.51-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"MD5Sum":"0f549ca16f4c13bea206e8a327c5adf8","Name":"hp-igb-kmp-default-6.19.4_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-09-16T08:24:58","Revision":"","SHA1Sum":"4615ea720d3792eed25da85cc48f1b2a1a55ccaa","SHA256Sum":"4c07f4482585faf7411ae528f2ad654eaa8b06e3023680bbf06129d4a2b486b4","Size":"175KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"TypeOfChange":"1","Version":"6.19.4-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel igbドライバーfor SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T04:31:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product updated to support new kernels.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は新しいカーネルをサポートするようにアップデートされました。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product updated to support new kernels.</p>","Lang":"cn"}],"Version":"6.19.3-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"6.19.4-1"}],"SWKeys":[{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"54df75fd199f48b4b8c9a20d15c0f96b"}]},{"ProductId":"3d4b3948a2e7454589365f36eee4d988","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304b584c5846","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VR000480KXLXF"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します: VR000480KXLXF"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VR000480KXLXF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This FW update contains the fix for false ILO message of temporary drive &quot;degraded&quot; status.</li><li>After the FW update, if the latest drive FW version is not correctly reflected in iLO under the scenarios outlined below, a system reboot or iLO reset may be required.<ul style=\"list-style-type:circle\"><li>HPK2 -&gt; HPK4 (or later version)</li><li>HPK3 -&gt; HPK4 (or later version)</li></ul></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付：</strong><br />     HPK4<br /><strong>最新の推奨またはクリティカルバージョン:</strong><br />     HPK4<br /><strong>以前のファームウェアバージョン：</strong><br />     HPK3<br /><strong>機能強化/新しい機能：</strong><br />     なし<br /><strong>修正された問題:</strong></p><ul><li>このFWアップデートには、ドライブの一時的な\"劣化\"ステータスに関する誤ったILOメッセージの修正が含まれています。</li><li>FWアップデート後、以下のシナリオで最新のドライブFWバージョンがiLOに正しく反映されない場合は、システムの再起動またはiLOのリセットが必要になる場合があります。<ul style=\"list-style-type:circle\"><li>HPK2 -> HPK4（またはそれ以降のバージョン）</li><li>HPK3 -> HPK4（またはそれ以降のバージョン）</li></ul></li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This FW update contains the fix for false ILO message of temporary drive &quot;degraded&quot; status.</li><li>After the FW update, if the latest drive FW version is not correctly reflected in iLO under the scenarios outlined below, a system reboot or iLO reset may be required.<ul style=\"list-style-type:circle\"><li>HPK2 -&gt; HPK4 (or later version)</li><li>HPK3 -&gt; HPK4 (or later version)</li></ul></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3165120","DateModified":"2025-05-14T07:41:21","FileList":["payload.json","Samsung_PM9A3_GPM9A3SAHPK4.HPb","Samsung_PM9A3_GPM9A3SAHPK4.xml"],"MD5Sum":"6063cec79c2d47ad17f0fa53abd45a43","Name":"Samsung_PM9A3_GPM9A3SAHPK4.fwpkg","Release":"2025-06-11T00:00:00","Revision":"","SHA1Sum":"2c23039e2f867225671fab0fcc1b9a982089fae1","SHA256Sum":"34e915bce71521266b3218cf37d2e1c1c0356161eaf17d09daa806633be4da48","Size":"3MB","TargetGUIDs":["562340a5-3052-3030-3438-304b584c5846"],"TypeOfChange":"1","Version":"HPK4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  VR000480KXLXF"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - VR000480KXLXF"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  VR000480KXLXF"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VR000480KXLXF","TargetGUID":"562340a5-3052-3030-3438-304b584c5846","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-28T08:59:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This FW update contains the fix for false ILO message of temporary drive &quot;degraded&quot; status.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWアップデートには、ドライブの一時的な\"劣化\"ステータスに関する誤ったILOメッセージの修正が含まれています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This FW update contains the fix for false ILO message of temporary drive &quot;degraded&quot; status.</li></ul>","Lang":"cn"}],"Version":"HPK4"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This FW update contains the fix for false ILO message of temporary drive &quot;degraded&quot; status.</li><li>After the FW update, if the latest drive FW version is not correctly reflected in iLO under the scenarios outlined below, a system reboot or iLO reset may be required.<ul style=\"list-style-type:circle\"><li>HPK2 -&gt; HPK4 (or later version)</li><li>HPK3 -&gt; HPK4 (or later version)</li></ul></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWアップデートには、ドライブの一時的な\"劣化\"ステータスに関する誤ったILOメッセージの修正が含まれています。</li><li>FWアップデート後、以下のシナリオで最新のドライブFWバージョンがiLOに正しく反映されない場合は、システムの再起動またはiLOのリセットが必要になる場合があります。<ul style=\"list-style-type:circle\"><li>HPK2 -> HPK4（またはそれ以降のバージョン）</li><li>HPK3 -> HPK4（またはそれ以降のバージョン）</li></ul></li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This FW update contains the fix for false ILO message of temporary drive &quot;degraded&quot; status.</li><li>After the FW update, if the latest drive FW version is not correctly reflected in iLO under the scenarios outlined below, a system reboot or iLO reset may be required.<ul style=\"list-style-type:circle\"><li>HPK2 -&gt; HPK4 (or later version)</li><li>HPK3 -&gt; HPK4 (or later version)</li></ul></li></ul>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"VR000480KXLXF","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"3f52ab4febe74549a2c97fc625b32d8c"}]},{"ProductId":"dc0fcbf999ba4988aa8b4eae8e8c9889","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />      オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ</p><p><strong>リリースバージョンおよび/または日付:<br />      </strong>HPG1<br /><br /><strong>最新の推奨またはクリティカルバージョン：<br />      </strong>なし<br /><br /><strong>前のファームウェアバージョン：</strong><br />      なし</p><p><strong>ファームウェアの関連性：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"}],"Files":[{"Bytes":"21446233","DateModified":"2025-03-06T04:53:54","FileList":["/CP065949_BUILD_2.data","/CP065949.vmexe64","/CP065949.vmfile","/CP065949_VMw.zip","/CP065949.xml","/payload.json","/CP065949_VMw.zip/index.xml","/CP065949_VMw.zip/vendor-index.xml","/CP065949_VMw.zip/metadata.zip","/CP065949_VMw.zip/vib20/CP065949/HPE_bootbank_CP065949_HPG1.2-1OEM.800.1.0.20613240.vib","/CP065949_VMw.zip/metadata.zip/vendor-index.xml","/CP065949_VMw.zip/metadata.zip/vmware.xml","/CP065949_VMw.zip/metadata.zip/vibs/CP065949--1036886056504614711.xml","/CP065949_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065949_HPG1.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"369669fe0af73a1a3c7b0e628482c47d","Name":"CP065949.zip","Release":"2025-03-06T04:53:03","Revision":"C","SHA1Sum":"0815a37a220d6eef63435ebdf6ca112c9b69f540","SHA256Sum":"685d6193676c04c7ec5604a22f20d0eced849a8e01f7da433b34f7eaa5d82037","Size":"20MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065949","Version":"HPG1.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040671.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives."},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK001920GZXQV","TargetGUID":"562340a5-304b-3130-3932-30475a585156","Type":"sata"},{"Id":"VK003840GZXRH","TargetGUID":"562340a5-304b-3330-3834-30475a585248","Type":"sata"},{"Id":"VK007680GZXRT","TargetGUID":"562340a5-304b-3730-3638-30475a585254","Type":"sata"},{"Id":"VK000960GZXQU","TargetGUID":"562340a5-304b-3030-3936-30475a585155","Type":"sata"},{"Id":"VK000480GZXRF","TargetGUID":"562340a5-304b-3030-3438-30475a585246","Type":"sata"},{"Id":"VK000240GZXRU","TargetGUID":"562340a5-304b-3030-3234-30475a585255","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:34:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3b34a42dbd6f4c9aa3887be86849e669"}]},{"ProductId":"0d61334622ba44aeb0c163514d9f57b9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB004000GWKGV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4516824","DateModified":"2025-11-16T11:34:12","FileList":["cp068743.xml","cpqsetup.exe","HVLAnAaseFG1.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"26685180d3d21648432bcd101ade06e9","Name":"cp068743.exe","Release":"2025-11-16T11:28:38","Revision":"K","SHA1Sum":"5706431b5ba5e66c325d8446d19096f3f84be2c6","SHA256Sum":"5e9e6a8954600e81584dfb560f604b9170921977cb8d1b039151c2ab21f34cfb","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWKGV Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB004000GWKGVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000GWKGV","TargetGUID":"4d2340a5-3042-3430-3030-3047574b4756","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T07:18:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2..</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2..</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"98e732bf3fe24672901b485ba22c9a13"}]},{"ProductId":"e9a45a84fc5a4ae9bee13ee0419530ca","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U47_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34049533","DateModified":"2026-01-12T01:52:03","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.54_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.54_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.54_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.54_2026_01_09-1.1/CP070301.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.54_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.54_2026_01_09-1.1/U47_2.54_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.54_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.54_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.54_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070301.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070301.scexe"],"MD5Sum":"3ecabc22bde739c92cbb03bf314133ac","Name":"firmware-system-u47-2.54_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-12T07:42:37","Revision":"","SHA1Sum":"3a4c38129ae2e53910e533107935b99081ce7a4c","SHA256Sum":"74bea68b7048e8bf693c0b04be35aae2f30a40b51ff02cba704ea29a69848595","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1Uノードおよび2Uノード受注構成サーバー（U47） "},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T07:42:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Whitley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.802（2.50_07_24_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"acc31e0904044ebaafbcbb910ef6f583"}]},{"ProductId":"41b320ad66f042c0996f23c6087a171e","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57412 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957412A4121HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41595","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957412A4121HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41595","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957412A4121HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Version":"235.1.164.14"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 Gigabit Ethernet NIC firmware."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"1384894","DateModified":"2025-12-11T09:17:14","FileList":["BCM235.1.164.14_BCM957412A4121HC.HPb","BCM235.1.164.14_BCM957412A4121HC.xml","payload.json"],"MD5Sum":"6aeb11d5b0a8cb3436003f00d3cea11e","Name":"BCM235.1.164.14_BCM957412A4121HC.fwpkg","Release":"2025-12-11T09:13:24","Revision":"","SHA1Sum":"f266993ad784fb8b97fb1d2947ac828b360c75cf","SHA256Sum":"9f80c3ef11c6363d8634634a0f97e2b8cd6467b0e6c34fccd888a51eb9968132","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41595"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM57412 adapter"},{"Lang":"ja","Value":"Broadcom Firmware Package for BCM57412 adapter"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM57412 adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-11T08:06:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"BCM_NXE_57412_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"872cf7c02e014e298e162243edcff4ef"}]},{"ProductId":"f5b93810cc2347bb802707c26e414376","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"22_46_3048-MCX623105AS-VDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30040","Version":"22.46.3048"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor MCX623105AS-VDAT Ethernet 200Gb 1ポートQSFP56アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE&nbsp;(P10180-B21)</td><td>22.46.3048</td><td>MT_0000000435</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE&nbsp;(P10180-B21)</td><td>22.46.3048</td><td>MT_0000000435</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE&nbsp;(P10180-B21)</td><td>22.46.3048</td><td>MT_0000000435</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7838225","DateModified":"2025-10-08T13:09:15","FileList":["22_46_3048-MCX623105AS-VDA_Ax.pldm.signed","22_46_3048-MCX623105AS-VDA_Ax.pldm.xml","payload.json"],"MD5Sum":"04a77c924fb64538130a98c5b44789e7","Name":"22_46_3048-MCX623105AS-VDA_Ax.pldm.fwpkg","Release":"2025-10-08T13:06:32","Revision":"","SHA1Sum":"f4590394d200f9de5214097fea1e9b82fdead9c2","SHA256Sum":"dfb182ea4c9885cd40b60f6c9472ac1a0b8855feb1ab2a3cd2cc8a690d32c25d","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"TypeOfChange":"1","Version":"22.46.3048"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ(FWPKG)for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1ポートQSFP56アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-24T07:02:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new features and changes have been&nbsp;included in version 22.45.1020.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 22.45.1020:</strong></p><ul><li>PCC_CNP_COUNT could not be reset using the pcc_counter.sh script in the DOCA tools.</li><li>VQoS algorithm issue related to learning when an element is active and when it begins sending traffic.</li><li>A race condition that would prevent the application from transmitting when VQoS was enabled.</li><li>Bandwidth would drop when unbinding multiple VFs with VQoS enabled.</li><li>RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port&#39;s MAC.</li></ul>","Lang":"en"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new features and changes have been&nbsp;included in version 22.45.1020.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 22.45.1020:</strong></p><ul><li>PCC_CNP_COUNT could not be reset using the pcc_counter.sh script in the DOCA tools.</li><li>VQoS algorithm issue related to learning when an element is active and when it begins sending traffic.</li><li>A race condition that would prevent the application from transmitting when VQoS was enabled.</li><li>Bandwidth would drop when unbinding multiple VFs with VQoS enabled.</li><li>RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port&#39;s MAC.</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new features and changes have been&nbsp;included in version 22.45.1020.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 22.45.1020:</strong></p><ul><li>PCC_CNP_COUNT could not be reset using the pcc_counter.sh script in the DOCA tools.</li><li>VQoS algorithm issue related to learning when an element is active and when it begins sending traffic.</li><li>A race condition that would prevent the application from transmitting when VQoS was enabled.</li><li>Bandwidth would drop when unbinding multiple VFs with VQoS enabled.</li><li>RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port&#39;s MAC.</li></ul>","Lang":"cn"}],"Version":"22.45.1020"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;22.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;22.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;22.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;22.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;22.46.3048:</strong></p><ul><li>Added support for RSS with crypto offload enabling the NIC to parallelize packet processing across CPU cores while performing encryption/decryption in hardware. Additionally, introduced a new l4_type_ext parameter with values: 0 (None), 1 (TCP), 2 (UDP), 3 (ICMP).</li><li>Added an extra validation for the payload_len field in incoming NC-SI messages. Previously, invalid packets might have been accepted; now, such packets are silently dropped.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;22.46.3048:</strong></p><ul><li>Configuring a small MTU led to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discarded these packets, causing the PXE boot to fail.</li></ul>","Lang":"cn"}],"Version":"22.46.3048"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"f5f2b713518d40dc9d3253b3376a2493"}]},{"ProductId":"05aa24e5db0c41fc91f79deb60685a31","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM1000JFJTH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000JFJTH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3800152","DateModified":"2025-11-17T06:05:18","FileList":["cp068663.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SAVGNSD5.rel","setup.dll"],"MD5Sum":"328f65d27c42df71e97c2dbceca67e55","Name":"cp068663.exe","Release":"2025-11-17T06:00:03","Revision":"F","SHA1Sum":"0b24b4f15be0b037eb90694792fe36bb92ca2942","SHA256Sum":"e6d870f51efe4198c85e1b30b22fe94e9586f78ea1e8ea8f795940555ebb37d6","Size":"3MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a464a5448"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000JFJTHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MM1000JFJTH","TargetGUID":"002340a5-4d00-314d-3030-304a464a5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:59:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MM1000JFJTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cc4e3aa900dc4921bb4b6a57ca7ae1de"}]},{"ProductId":"d09d3bc174174ab69b229c1370a5ce48","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD5<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"3255088","DateModified":"2025-11-15T04:09:20","FileList":["cp068763.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA15SEN0HPD6.rel"],"MD5Sum":"014284e1c5e3cde9453f801c40572a19","Name":"cp068763.exe","Release":"2025-11-15T04:05:04","Revision":"B","SHA1Sum":"8229f5d9249c1a4d76bff4a581aaea9da46adfbe","SHA256Sum":"d7d3fadc15fc0935e9011d00b8f2e856d78226775edb127e57509f78bf3b84d9","Size":"3MB","TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EG001200JWJNK","TargetGUID":"452340a5-3047-3130-3230-304a574a4e4b","Type":"sas"},{"Id":"EG000600JWJNH","TargetGUID":"452340a5-3047-3030-3630-304a574a4e48","Type":"sas"},{"Id":"EG000300JWSJP","TargetGUID":"452340a5-3047-3030-3330-304a57534a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T09:48:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスの改訂により、ドライブ全体のパフォーマンスが向上します。</li><li>このファームウェアにアップグレードしない場合、特定のエラーおよびタイミング条件下でドライブがハングアップする可能性が高まります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>このメンテナンスの改訂により、ドライブ全体のパフォーマンスが向上します。</li><li>このファームウェアにアップグレードしない場合、特定のエラーおよびタイミング条件下でドライブがハングアップする可能性が高まります。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e186208a59f74883a23b4da1fb8e4c79"}]},{"ProductId":"dc41774861a945f28d388059e656b2ca","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_OCP_4p90_NCSIwPLDMoMCTP_80020EF8.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"4.90"}]},"MinimumActiveVersion":"4.20","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-CQDA2 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td><td>80020EF8</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2ポートQSFP28 OCP3アダプター</td><td>80020EF8</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.9と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td><td>80020EF8</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"}],"Files":[{"Bytes":"10526592","DateModified":"2025-12-18T07:17:08","FileList":["HPE_E810_CQDA2_OCP_4p90_NCSIwPLDMoMCTP_80020EF8.HPb","HPE_E810_CQDA2_OCP_4p90_NCSIwPLDMoMCTP_80020EF8.xml","payload.json"],"MD5Sum":"1fd8b59553b434043097ec9c1fd19229","Name":"HPE_E810_CQDA2_OCP_4p90_NCSIwPLDMoMCTP_80020EF8.fwpkg","Release":"2025-12-18T07:13:52","Revision":"B","SHA1Sum":"f5ea5d9dccb3436b8a46a2a15c0c8dfb142207c8","SHA256Sum":"f0f71d7ebead249ad1bb0a0a52725158905a11e119a68a62aab67da57a276b41","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860006"],"TypeOfChange":"1","Version":"4.90"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-CQDA2 Ethernet 100Gb 2ポートQSFP28 OCP3アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-18T06:15:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</li><li>This product enhanced media type detection function on PHY on 100G adapter.</li></ul>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</li><li>この製品は、100GアダプターのPHY上のメディアタイプ検出機能を強化しました。</li></ul>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</li><li>This product enhanced media type detection function on PHY on 100G adapter.</li></ul>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"},{"ReleaseNotes":[{"Enhancements":"<ul><li>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</li><li>This product enhanced media type detection function on PHY on 100G adapter.</li></ul>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</li><li>この製品は、100GアダプターのPHY上のメディアタイプ検出機能を強化しました。</li></ul>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</li><li>This product enhanced media type detection function on PHY on 100G adapter.</li></ul>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"}],"SWKeys":[{"Name":"INTEL_E810_CQ2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"6cc7727b8c274fa286c8994ac74f96a5"}]},{"ProductId":"139d2679780d42b2a020c2a6176ac11b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"4018280","DateModified":"2025-11-17T12:19:16","FileList":["cp068650.xml","cpqsetup.exe","KAPM6ALSHPD5.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"179fcff5d4e2a1ebda99b9cc885bcbcf","Name":"cp068650.exe","Release":"2025-11-17T12:14:31","Revision":"B","SHA1Sum":"ba46621b84faaedee4245d5565d825d7b6e6d6f4","SHA256Sum":"f9d5f1710756a94fb07262d2f72699271b7cb6c170b7a34bf763c2f2195c4616","Size":"3MB","TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EO000800PXDCK","TargetGUID":"452340a5-304f-3030-3830-30505844434b","Type":"sas"},{"Id":"MO000800PXDBP","TargetGUID":"4d2340a5-304f-3030-3830-305058444250","Type":"sas"},{"Id":"EO000400PXDBQ","TargetGUID":"452340a5-304f-3030-3430-305058444251","Type":"sas"},{"Id":"EO001600PXDCH","TargetGUID":"452340a5-304f-3130-3630-305058444348","Type":"sas"},{"Id":"MO001600PXDCC","TargetGUID":"4d2340a5-304f-3130-3630-305058444343","Type":"sas"},{"Id":"MO006400PXDCE","TargetGUID":"4d2340a5-304f-3630-3430-305058444345","Type":"sas"},{"Id":"VO007680PXDBU","TargetGUID":"562340a5-304f-3730-3638-305058444255","Type":"sas"},{"Id":"VO001920PXDBR","TargetGUID":"562340a5-304f-3130-3932-305058444252","Type":"sas"},{"Id":"VO015300PXDBV","TargetGUID":"562340a5-304f-3531-3330-305058444256","Type":"sas"},{"Id":"MO003200PXDCD","TargetGUID":"4d2340a5-304f-3330-3230-305058444344","Type":"sas"},{"Id":"VO000960PXDBN","TargetGUID":"562340a5-304f-3030-3936-30505844424e","Type":"sas"},{"Id":"VO003840PXDBT","TargetGUID":"562340a5-304f-3330-3834-305058444254","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:38:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブヘルスのクエリが誤ったドライブ予測エラーを引き起こす可能性がある、まれなケースに対処するための修正を追加しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"24c1872edd3c444aab7090b24fb77669"}]},{"ProductId":"ed7a5d4d2f9c4a55ba7dea78369f1389","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Windows Server 2022用 HPE Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"},{"Lang":"cn","Value":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1112544","DateModified":"2025-11-17T02:55:15","FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.man","bnxtnd.sys","cp068540.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"484f4e7a93f0e172b1c4095125136be7","Name":"cp068540.exe","Release":"2025-11-17T02:41:02","Revision":"","SHA1Sum":"f6a80d37b19a590e95aff477547002dff7a7c5e3","SHA256Sum":"e4a8fcffb02ad3df6e864ce867211ee7f123b11df781273c82c04b20434d7f7f","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"235.1.122.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-27T06:12:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances to improve user mode RDMA abortive cleanup.</li><li>This product enhances FW logging to host to work across device reset.</li></ul>","Fixes":"<p>This product fixes issue where packet drops is seen when jumbo frame is enabled.</p>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、ユーザーモードのRDMA中止クリーンアップを改善するように強化されています。</li><li>この製品は、デバイスのリセット後も機能するようにホストへのFWログ記録を強化します。</li></ul>","Fixes":"<p>この製品は、ジャンボフレームが有効になっている場合にパケットドロップが発生する問題を修正します。</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances to improve user mode RDMA abortive cleanup.</li><li>This product enhances FW logging to host to work across device reset.</li></ul>","Fixes":"<p>This product fixes issue where packet drops is seen when jumbo frame is enabled.</p>","Lang":"cn"}],"Version":"233.0.148.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.<br />&nbsp;</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.<br />&nbsp;</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.<br />&nbsp;</li></ul>","Fixes":"","Lang":"cn"}],"Version":"235.1.122.0"}],"SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"8e14684cfcb5422a81e71f5516719a9d"}]},{"ProductId":"c4ff2ade728c42bfb931931df173daf9","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SPSGen10_04.01.05.201.signed.bin","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.201"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8414431","DateModified":"2025-08-04T09:27:18","FileList":["payload.json","SPSGen10_04.01.05.201.signed.bin","SPSGen10_04.01.05.201.xml"],"MD5Sum":"f64e3542e28cd6e6a83bf6e58331a640","Name":"SPSGen10_04.01.05.201.fwpkg","Release":"2025-08-04T09:24:31","Revision":"","SHA1Sum":"9bacff75d60bb49a10f4458ee4ebaf906a4f400a","SHA256Sum":"eda79113a7263eb221897c8b6eaac1ff59d6e776fa9d0cedd0a8d637bcba63c3","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.201"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"Lang":"ja","Value":"ROMフラッシュ ファームウェアパッケージ - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-28T07:18:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.01.05.105は、システムROM 3.40 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.01.05.105"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"04.01.05.201"}],"SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"55b6b49088e34c1484eb0eba7e0d05ce"}]},{"ProductId":"f66d2f40fe3b49a2ae22ce155e429f5c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQNドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6189570","DateModified":"2025-09-17T11:17:17","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/CP068801.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/SCIMARRNESD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068801.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068801.scexe"],"MD5Sum":"239a91ce0e78ce29b461fc40b1c3a155","Name":"firmware-hdd-ae6b41e855-HPD8-8.1.x86_64.rpm","Release":"2025-09-17T16:06:21","Revision":"H","SHA1Sum":"5e86971e665507a0bc0b75c0b1d7847c52dc69c8","SHA256Sum":"1395f9e09bfdfdb5e1649adaddae09959c043985775e9f84c69ac8eaa00def66","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP043258.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000JWWQN","TargetGUID":"4d2340a5-3042-3630-3030-304a5757514e","Type":"sas"},{"Id":"MB008000JWWQP","TargetGUID":"4d2340a5-3042-3830-3030-304a57575150","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T03:48:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"582f979e397949ae897a999f648304c6"}]},{"ProductId":"33474bdb31ec42199bc00637b81a4d15","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"15231328","DateModified":"2025-12-11T14:08:13","FileList":["93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","Config.xml","cp070013.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","VDUFlash.dll"],"MD5Sum":"3516842d22a8119f07e8c3430c06a1c6","Name":"cp070013.exe","Release":"2025-12-11T14:04:54","Revision":"J","SHA1Sum":"77c9e7f1f9babc82ed31bbc48ece7a9cdf7980d5","SHA256Sum":"658c13731e2cc51561a1abc1e134116babaaf1ac216037028cee73df4ed58915","Size":"14MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/t D8000 /v 0130 /i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff /i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff /l D8000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"ja","Value":"HPE D8000 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"},{"Lang":"cn","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2"},"SupportedDevices":[{"Id":"D8000 12Gb Enclosure","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"},{"Id":"D8000 12Gb IO","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-09T10:30:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v275933/20-D8000-Gen10RN0130K_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"}],"SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8b87310ce1514fe895401d1f8be7e648"}]},{"ProductId":"e6bb5c297d78402ab079f188773b5efc","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2022."},{"Lang":"ja","Value":"This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2022."},{"Lang":"cn","Value":"This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"2460360","DateModified":"2025-11-17T01:07:16","FileList":["cp068343.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"e6a1b69f1a3104135388875e44f709bc","Name":"cp068343.exe","Release":"2025-11-17T00:52:39","Revision":"","SHA1Sum":"0297dacbbcf23ee1bf928bdfd8b68ccc697c8ec8","SHA256Sum":"8ec0ee3a37cc01758213ff032efb46add706e8ed556be61f8958ca42da616a70","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.7.26882.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox WinOF2 Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"Mellanox WinOF2 Driver for Microsoft Windows Server 2022"},{"Lang":"cn","Value":"Mellanox WinOF2 Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30117","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30040","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30102","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30047","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30116","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30052","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0012","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30012","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0007","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30007","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-13T02:39:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"en"},{"Enhancements":"<p>Windows上のDOCAテレメトリライブラリに対するサポートが追加されました。</p>","Fixes":"<ul><li>この製品では、ファームウェアが機能していない場合にサスペンド/再開プロセス中にBSODが発生する可能性がある問題が修正されました。</li><li>この製品では、アダプターが無効化されている場合、マルチセグメントPCIマシン上で「Mlx5Cmd -Stat」が物理的な位置情報を誤って表示する問題を修正しました。</li><li>この製品では、イベント399に誤った情報が表示される問題が修正されました。</li><li>この製品は、VMQ/SR-IOVモードで動作するアダプター上でpktmonを有効化または無効化する際に、エラーイベント410および304が発生する問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"cn"}],"Version":"25.4.26768.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"cn"}],"Version":"25.7.26882.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4fedece91cda4c77a4733cae02ce9f28"}]},{"ProductId":"a6fc6d419cd14563aeefb1d3f50c589e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U61_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.52 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17451568","DateModified":"2026-01-13T08:05:10","FileList":["cp070161.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U61_2.52_01_09_2026.signed.flash"],"MD5Sum":"5ca27a83244ce2bcd3d93f2f8d2bccb6","Name":"cp070161.exe","Release":"2026-01-13T08:02:49","Revision":"","SHA1Sum":"9f88058d16ecc87fc0601ffc00eca2fa742d86b9","SHA256Sum":"cb4db8a41f84851a42e4ba93b352c8b57414e1d3bcac9dc73b37b421530b3363","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.52_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML30 Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T06:07:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.708（2.50_07_25_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_01-09-2026"}],"SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"9698d7ba9b81461984806784b50fb774"}]},{"ProductId":"f25420df1f7142d3a5eccbf213f27251","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A47_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34235936","DateModified":"2026-01-13T02:36:05","FileList":["A47_4.00_01_09_2026.signed.flash","cp070339.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"8ca8298689eadf3f796a802484a8787c","Name":"cp070339.exe","Release":"2026-01-13T02:33:02","Revision":"","SHA1Sum":"e27adc61d054d22948ccf17784bc85dd67a37681","SHA256Sum":"8b76b9aab51e1ea0a344fc6aa61136859451216e2cbb324ebde3f0e405086104","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:32:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV/SNP feature would not function correctly on the DL325 Gen10 Plus server.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.90_10-03-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"b4076ef4dc364ac983a17039f86029bb"}]},{"ProductId":"862d36dd920c478ca6dcfdb5f392893a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWWQUおよびMB006000GWWQTドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5888829","DateModified":"2025-09-21T22:39:45","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/CP068936.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/SCIMARRNETG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068936.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068936.scexe"],"MD5Sum":"021f6713e6678243766b1f22afc5130a","Name":"firmware-hdd-18e328f036-HPG8-6.1.x86_64.rpm","Release":"2025-09-22T03:27:05","Revision":"F","SHA1Sum":"b0861590d648bbc28cd178db74a87c639a8e661a","SHA256Sum":"6bd5e6a503912a573d4fc2d1aaf337f72a587164765cbdd09f03af8b89a9efba","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"Installation":{"Command":"CP043252.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000GWWQU","TargetGUID":"4d2340a5-3042-3830-3030-304757575155","Type":"sata"},{"Id":"MB006000GWWQT","TargetGUID":"4d2340a5-3042-3630-3030-304757575154","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:17:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul>","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4a2cf298e2444835a79f0b2da8621f47"}]},{"ProductId":"0c7b64360b5c406b8354ad889f429454","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None.</p><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None.</p><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"4829452","DateModified":"2025-08-02T21:21:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-1.1/CP067374.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-1.1/WLEBsssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067374.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067374.scexe"],"MD5Sum":"17c7355e651264f004cdc70f64892c3f","Name":"firmware-hdd-cfd7436fcc_0HPD4-1.1_amd64.deb","Release":"2025-08-03T02:15:05","Revision":"","SHA1Sum":"1b9406b4c671e943eaa32ca2543fe60f949de538","SHA256Sum":"e8ff5655219c6b484184b23d3f014cd0156aaeff40f7b49ba80679a507a24d7a","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP041518.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWUDB Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWUDB Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JWUDB","TargetGUID":"4d2340a5-3042-3431-3030-304a57554442","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T20:58:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Corrective actions to fix potential background media scan issue.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Corrective actions to fix potential background media scan issue.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Corrective actions to fix potential background media scan issue.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fec44508fdf14033bb495fbe34b33b95"}]},{"ProductId":"22b7710ad6de471aa3aeacbb94b82c36","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"3543952","DateModified":"2025-08-02T22:48:27","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-1.1/CP067392.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-1.1/TA15SEN0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067392.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067392.scexe"],"MD5Sum":"1852d56f43998ab101a7539273c64575","Name":"firmware-hdd-24fe569b72_0HPD6-1.1_amd64.deb","Release":"2025-08-03T03:41:26","Revision":"","SHA1Sum":"b0d0e023d9cae31846727ca1161c83813110711e","SHA256Sum":"7460b9eb3f7aeb2df884973123c787f3f9a4c6ad79290e87e11e090f52ff43c2","Size":"3MB","TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"CP041564.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG001200JWJNK","TargetGUID":"452340a5-3047-3130-3230-304a574a4e4b","Type":"sas"},{"Id":"EG000600JWJNH","TargetGUID":"452340a5-3047-3030-3630-304a574a4e48","Type":"sas"},{"Id":"EG000300JWSJP","TargetGUID":"452340a5-3047-3030-3330-304a57534a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:36:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7b4446ea493f4ed5a55d691a1fa39c00"}]},{"ProductId":"009bd5d739814a67a018565d835c45f1","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U41_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11630344","DateModified":"2026-01-14T05:30:57","FileList":["cp070261.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U41_3.62_01_09_2026.signed.flash"],"MD5Sum":"14a8097c47499b4bb1d476b382342b2f","Name":"cp070261.exe","Release":"2026-01-14T05:28:33","Revision":"","SHA1Sum":"014003da127251fa5186caa50d60611c630cf7cf","SHA256Sum":"ead1e0fcba883112de763c79f33245185f2c6f73efb38266b9a14050bdfe9bef","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen10 (U41) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML350 Gen10 (U41) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen10 (U41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T06:22:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"d36e2c20c72a4e26b6576799ed18838d"}]},{"ProductId":"b8bfd68496a643cdaece510776fb4ad2","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントには、Mircosoft Windows Server 2022用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"},{"Lang":"cn","Value":"This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1111008","DateModified":"2025-11-17T03:30:13","FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp069012.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"8f1ae98c82007620a76034adc660502b","Name":"cp069012.exe","Release":"2025-11-17T03:15:34","Revision":"","SHA1Sum":"af071a96986df475eca0de6cacdbd6b2b33d5608","SHA256Sum":"371cc5d026e24de8a2632095a3b13f6668aa66f38b7f19944eb44364018e5bdf","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"235.1.122.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"Broadcom NetXtreme-Eドライバーfor Microsoft Windows Server 2022"},{"Lang":"cn","Value":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41593","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41592","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e124","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e124","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41595","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41597","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d8","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"1760","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e41760","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D6","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d6","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d7","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41593","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41592","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41595","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41597","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41596","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1808","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180814e41599","Type":"pci","Ven":"14e4"},{"Dev":"1808","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180814e41598","Type":"pci","Ven":"14e4"},{"Dev":"1809","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180914e41599","Type":"pci","Ven":"14e4"},{"Dev":"1809","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180914e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1751","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41751","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41599","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41598","Type":"pci","Ven":"14e4"},{"Dev":"1807","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180714e41599","Type":"pci","Ven":"14e4"},{"Dev":"1807","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180714e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1808","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-180800000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-181B00000000","Type":"pci","Ven":"14E4"},{"Dev":"1809","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-180900000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-181B00000000","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-02T03:12:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances to improve user mode RDMA abortive cleanup.</li><li>This product enhances FW logging to host to work across device reset.</li></ul>","Fixes":"<p>This product fixes issue where packet drops is seen when jumbo frame is enabled.</p>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、ユーザーモードのRDMA中止クリーンアップを改善するように強化されています。</li><li>この製品は、デバイスのリセット後も機能するようにホストへのFWログ記録を強化します。</li></ul>","Fixes":"<p>この製品は、ジャンボフレームが有効になっている場合にパケットドロップが発生する問題を修正します。</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances to improve user mode RDMA abortive cleanup.</li><li>This product enhances FW logging to host to work across device reset.</li></ul>","Fixes":"<p>This product fixes issue where packet drops is seen when jumbo frame is enabled.</p>","Lang":"cn"}],"Version":"233.0.148.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances the Windows driver to support PCIe compliance configuration by enabling pass-through firmware commands with long input message sizes.</li><li>This product enhances adding new event log warning message.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"235.1.122.0"}],"SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3119d5cadfcc43c7ad4f3bffb49d7fa9"}]},{"ProductId":"e774fea9b642407a9f2687df296d352e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1418032","DateModified":"2025-11-16T12:20:18","FileList":["cp069530.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","manifest_iavf68.man","nicdrvr.dll"],"MD5Sum":"3e86f295e3599b467ea49145448dcd53","Name":"cp069530.exe","Release":"2025-11-16T12:06:04","Revision":"B","SHA1Sum":"e68f195b6d480f9e637ba1d0346888786f76a91b","SHA256Sum":"be7b599d2861af0e968977a85aceac7f81542fac3baa8612b6385442d180e7a2","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"TypeOfChange":"1","Version":"1.17.63.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel iavf Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel iavfドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel iavf Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CD","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37CD15900000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-154c103c0000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:50:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、VFドライバーが無効になっているかインストールされていない場合にVMトラフィックが機能しない可能性がある問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、VFドライバーが無効になっているかインストールされていない場合にVMトラフィックが機能しない可能性がある問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"}],"SWKeys":[{"Name":"iavf68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"31eca7f4f32245f785d0042d0d3c6483"}]},{"ProductId":"43151427676f44dcaced68356cf6359c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE Intel igbnアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.12.2.0</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;1.12.2.0</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.12.2.0</p>"}],"Files":[{"Bytes":"140880","DateModified":"2025-03-05T03:47:21","FileList":["/cp066052.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vib20/igbn/INT_bootbank_igbn_1.12.2.0-1OEM.800.1.0.20613240.vib","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vmware.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vibs/igbn--4585876958502114762.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/bulletins/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"4fc99fa497b8339f434cde2e25db2b3d","Name":"cp066052.zip","Release":"2025-03-05T03:24:04","Revision":"","SHA1Sum":"a7dd979017be67ed61120299c256e639f6e99901","SHA256Sum":"378907c9d3ccff4bc35a6bc7124b047ab90c517a90d275aaffeb5f3b493d3894","Size":"137KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"igbn","Version":"1.12.2.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel igbn Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE Intel igbnドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Intel igbn Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-03T05:21:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product added support to new Gen11 servers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品では、新しいGen11サーバーのサポートを追加しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product added support to new Gen11 servers.</p>","Fixes":"","Lang":"cn"}],"Version":"2024.09.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.05.00"}],"SWKeys":[{"Name":"Intel-igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"91eedfc8544c413bbd1e5e7e2f1c20f9"}]},{"ProductId":"188f54d508794fafbb14f21866a0ffb5","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6406124","DateModified":"2025-09-17T12:22:45","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/CP068843.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/HVLAnAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068843.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068843.scexe"],"MD5Sum":"dedbb27061b117bfdb9c96b1e86848df","Name":"firmware-hdd-2c27a7a9a4-HPD2-10.1.x86_64.rpm","Release":"2025-09-17T17:11:05","Revision":"J","SHA1Sum":"863a7b0ed617aa7239fbdf25e9a56823f9736085","SHA256Sum":"c4f293c342178bb600047e509a4758c53bd42d7c60795ea699bc4d9ec551d5e8","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041491.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB004000JWKGU ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JWKGU","TargetGUID":"4d2340a5-3042-3430-3030-304a574b4755","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T18:35:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"018279bc0bb148e6a910474b45a16287"}]},{"ProductId":"74085bfad3ea4badb1e5c0235f47c1ea","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5885294","DateModified":"2025-09-21T21:39:39","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/CP068923.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/KAPM6ALSHPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068923.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068923.scexe"],"MD5Sum":"bca66fb8242af09ab3eff710c9653ef7","Name":"firmware-hdd-42aff4675b-HPD5-2.1.x86_64.rpm","Release":"2025-09-22T02:30:10","Revision":"B","SHA1Sum":"df129b058635f8a851fa802deda698e30d2705e0","SHA256Sum":"ea1001cc06988b542ee1892e0e53c8c93aa0cbe2de3ec0cf74a757f5adf33581","Size":"5MB","TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP041670.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64） - EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EO000800PXDCK","TargetGUID":"452340a5-304f-3030-3830-30505844434b","Type":"sas"},{"Id":"MO000800PXDBP","TargetGUID":"4d2340a5-304f-3030-3830-305058444250","Type":"sas"},{"Id":"EO000400PXDBQ","TargetGUID":"452340a5-304f-3030-3430-305058444251","Type":"sas"},{"Id":"EO001600PXDCH","TargetGUID":"452340a5-304f-3130-3630-305058444348","Type":"sas"},{"Id":"MO001600PXDCC","TargetGUID":"4d2340a5-304f-3130-3630-305058444343","Type":"sas"},{"Id":"MO006400PXDCE","TargetGUID":"4d2340a5-304f-3630-3430-305058444345","Type":"sas"},{"Id":"VO007680PXDBU","TargetGUID":"562340a5-304f-3730-3638-305058444255","Type":"sas"},{"Id":"VO001920PXDBR","TargetGUID":"562340a5-304f-3130-3932-305058444252","Type":"sas"},{"Id":"MO003200PXDCD","TargetGUID":"4d2340a5-304f-3330-3230-305058444344","Type":"sas"},{"Id":"VO015300PXDBV","TargetGUID":"562340a5-304f-3531-3330-305058444256","Type":"sas"},{"Id":"VO000960PXDBN","TargetGUID":"562340a5-304f-3030-3936-30505844424e","Type":"sas"},{"Id":"VO003840PXDBT","TargetGUID":"562340a5-304f-3330-3834-305058444254","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:05:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1acfb6855d7e460f8e0c563239e759a9"}]},{"ProductId":"799e6d2dd6574724a67dc3ea392d2873","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"Lang":"cn","Value":"可升级 HPE ProLiant Gen9 扩展卡上机柜固件的补充更新/在线 ROM Flash 智能组件"},{"Lang":"ja","Value":"HPE ProLiant Gen9エキスパンダー上のエンクロージャーファームウェアをアップグレードするサプリメンタルアップデート / オンラインROMフラッシュSmartコンポーネント"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5424074","DateModified":"2025-10-07T03:42:34","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/CP068826.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/firmware-Signed-5.15-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068826.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068826.scexe"],"MD5Sum":"ea7ddef09aa7cfe497408e8aa94d17c4","Name":"firmware-smartarray-1f19a4a64d-5.15-6.1.x86_64.rpm","Release":"2025-10-07T08:25:18","Revision":"F","SHA1Sum":"741ed5eccaa8a8a04b8b81bc05affbc222d63029","SHA256Sum":"eff9d7569abed1473c11bb8b0a5ee80afa685f2228b11178920a18d9e8a7048c","Size":"5MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"Installation":{"Command":"CP068826.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the&nbsp;USB Key Utility for Windows.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the&nbsp;USB Key Utility for Windows.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p><ul><li>次のコマンドを使用してファームウェアrpmをインストールします：  rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em> <rpm_filename>  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します</li><li>CPXXXXXX.scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-smartarray-1f19a4a64d-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>./CPXXXXXX.scexe ('/usr/lib/x86_64-linux-gnu/scexe-compat'で実行) (または)</li><li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*'の場所に<em>./setup</em>を追加してください</li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em> ('.rpm'拡張子の付いていないrpmファイル名) を実行します。</li></ul><p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p><ul><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id  </em>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-1f19a4a64d-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong><em>追加情報:</em></strong></p><p>ファームウェアrpmパッケージのインストール (rpm -ivh) は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li>USB Key Utility for Windowsを使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li><li>ISOのルートにある launch_sum.sh スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"cn","Value":"Linux (x64)版补充更新/在线ROM刷新组件 – 适用于HPE智能阵列控制器和HPE HBA控制器的HPE 12Gb/s SAS扩展器固件"},{"Lang":"ja","Value":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - HPE 12 Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-10-16T07:04:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10サポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.15"},{"ReleaseNotes":[{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"cn"}],"Version":"5.15"}],"SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"00fabe6608db428a9aa80c4965341932"}]},{"ProductId":"f148b53c7b96447699a0d01706827644","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4704-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.4704"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.8002"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームでHPE Apollo A10 InfiniBand EDR（100Gb）2ポートアダプター（HPE部品番号843400-B21）、HPE Apollo InfiniBand EDR 100Gb 2ポート841zメザニンアダプター（HPE部品番号872723-B21）、HPE InfiniBand EDR 100Gb 1ポート841QSFP28アダプター（HPE部品番号872725-B21）のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Linux x86_64 platform."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.4704</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.8002</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.8002</td><td>HPE0000000008</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.4704</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.8002</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.8002</td><td>HPE0000000008</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.4704</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.8002</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.8002</td><td>HPE0000000008</td></tr></tbody></table>"}],"Files":[{"Bytes":"7885492","DateModified":"2025-10-12T13:03:04","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/CP069162.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/nic_fw/fw-ConnectX4-rel-12_28_4704-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/nic_fw/fw-ConnectX5-rel-16_35_8002-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/nic_fw/fw-ConnectX5-rel-16_35_8002-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069162.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069162.scexe"],"MD5Sum":"ca50dc91796dcfacb90d8976abd37820","Name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.17-1.1.x86_64.rpm","Release":"2025-10-12T17:59:28","Revision":"","SHA1Sum":"ff21b16ecea74e5d325e9128281dd1a85f013001","SHA256Sum":"c5e4d734eb753a820e4768cfa7adc085faf230ff5c43eb25b1df293e13f0af1f","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"TypeOfChange":"1","Version":"1.0.17"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ（Linux x86_64）for HPE Mellanox IB専用ConnectX4とConnectX5デバイス - Linux x86_64プラットフォーム"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00EF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000ef","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0257","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900257","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0255","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900255","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-12T16:19:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2ポートアダプター)<br /> </li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>872723-B21(HPE Apollo InfiniBand EDR 100Gb 2ポート841zメザニンアダプター)</li><li>872725-B21(HPE InfiniBand EDR 100Gb 1ポート841QSFP28アダプター)</li></ul><p> </p><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302では、新たな問題は修正されていません。</strong></p><p> </p><p><strong>以下の問題点がバージョン16.35.4506で修正されました。</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.16"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.8002:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.8002:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.4704:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.8002:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 12.28.4704:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 12.28.4704.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.17"}],"SWKeys":[{"Name":"Mellanox_IB_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"77417865ef114c4eb255adbb2e05a6c5"}]},{"ProductId":"24db3c54a571487f8640586ecf4c8ce6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improvement in mixed READ/WRITE performance, which was causing a field issue at an HPE customer -&nbsp;Improve random mix performance in TL=2048k and 512k</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improvement in mixed READ/WRITE performance, which was causing a field issue at an HPE customer -&nbsp;Improve random mix performance in TL=2048k and 512k</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3625824","DateModified":"2025-08-02T21:54:03","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-1.1/CP067385.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-1.1/TAMG06ACHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067385.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067385.scexe"],"MD5Sum":"84f78ff592bde24d81d72cd5ea4f272d","Name":"firmware-hdd-c993b31232_0HPG6-1.1_amd64.deb","Release":"2025-08-03T02:46:14","Revision":"","SHA1Sum":"7515f50701284e6a103ecc7a116c094e53208dc0","SHA256Sum":"44adfa731d910288502486f595409b9b727aa1b2960dff1f32870ce5565640ad","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP041676.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000GWJRT","TargetGUID":"4d2340a5-3042-3830-3030-3047574a5254","Type":"sata"},{"Id":"MB006000GWJRR","TargetGUID":"4d2340a5-3042-3630-3030-3047574a5252","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:22:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improvement in mixed READ/WRITE performance, which was causing a field issue at an HPE customer -&nbsp;Improve random mix performance in TL=2048k and 512k</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Improvement in mixed READ/WRITE performance, which was causing a field issue at an HPE customer -&nbsp;Improve random mix performance in TL=2048k and 512k</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improvement in mixed READ/WRITE performance, which was causing a field issue at an HPE customer -&nbsp;Improve random mix performance in TL=2048k and 512k</li></ul>","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"27dc2d8802b34bdfb4962861fd18ef2f"}]},{"ProductId":"348f4fc22c0c4f64b2e050cebccb4347","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp068057.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2926968","DateModified":"2025-11-14T07:08:14","FileList":["cp068057.compsig","cp068057.zip","cp069640.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"73ce19c9d2157f01c59c4992bfb8a977","Name":"cp069640.exe","Release":"2025-11-14T07:06:19","Revision":"B","SHA1Sum":"4538a57dbb559a72f01756a0701446f86ab7ea69","SHA256Sum":"ea1ef4a3e2550df25b8a549100d3e5163d6c79d3620b5d6ee9890c83d2d4bcb2","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - Server Platform Services (SPS)ファームウェア for HPE ProLiant MicroServer Gen10 Plus v2"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T06:41:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d2f74bf1d1cf4b6db112111fb7a8ba24"}]},{"ProductId":"95cd675c9c4947eda03bc921bfff84c3","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08ADAeG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3630-3030-3047575a564c","Version":"HPG3"},{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08ADAeG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3830-3030-3047575a564e","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB006000GWZVL and MB008000GWZVN"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MB006000GWZVL and MB008000GWZVN"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB006000GWZVL and MB008000GWZVN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1281827","DateModified":"2024-07-09T04:20:19","FileList":["payload.json","Toshiba_MG08Air_TAMG08ADAeG3.HPb","Toshiba_MG08Air_TAMG08ADAeG3.xml"],"MD5Sum":"30dd23d4e1b0b2985979edc5276ab653","Name":"Toshiba_MG08Air_TAMG08ADAeG3.fwpkg","Release":"2024-07-09T04:16:07","Revision":"","SHA1Sum":"f08231e60ff630527f7f35a652abbe1348965d21","SHA256Sum":"7eb28ad95d2e036e5141cd435f5162cc7a53e373089a2ea8c98253e010c5247e","Size":"1MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047575a564c","4d2340a5-3042-3830-3030-3047575a564e"],"TypeOfChange":"2","Version":"HPG3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB006000GWZVL and MB008000GWZVN"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MB006000GWZVL and MB008000GWZVN"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB006000GWZVL and MB008000GWZVN"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB006000GWZVL","TargetGUID":"4d2340a5-3042-3630-3030-3047575a564c","Type":"sata"},{"Id":"MB008000GWZVN","TargetGUID":"4d2340a5-3042-3830-3030-3047575a564e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-08-09T03:43:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us</a>&nbsp;which will be active on&nbsp;24-April-2024.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。  このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li><li>詳しくは、HPEカスタマーアドバイザリ: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us</a>（2024年4月24日に有効になります）を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us</a>&nbsp;which will be active on&nbsp;24-April-2024.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity. &nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity. &nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity. &nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB006000GWZVL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB008000GWZVN","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"22b25cb7056247fca6f226ad387ab8a6"}]},{"ProductId":"8a01a8f2913f46979fa6206b3faeb0eb","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"8007632","DateModified":"2025-11-17T07:59:20","FileList":["cp068640.xml","cpqsetup.exe","mnv_cli.exe","MPK7825Q.rel","payload.json","setup.dll"],"MD5Sum":"d8ac8b6c3bba435290814b721f0ebefd","Name":"cp068640.exe","Release":"2025-11-17T07:54:22","Revision":"C","SHA1Sum":"7a41ae94dcbc0083ecfdedd576b5b8c3e7129685","SHA256Sum":"b71425c25e9587f3cd160c3bc13b98972359749dd0884599232d726f9d2710c0","Size":"7MB","TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-0 Drives"},{"Lang":"ja","Value":"Windows（x64）用オンラインNVMe SSDフラッシュコンポーネント - MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-0ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MZXLR12THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3132-544869b8df72","Type":"nvme"},{"Id":"MZXLR15THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3135-5448e88a517e","Type":"nvme"},{"Id":"MZXLR7T6HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3754-36484bc80db1","Type":"nvme"},{"Id":"MZXLR1T6HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Type":"nvme"},{"Id":"MZXLR800HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3830-3048c3876295","Type":"nvme"},{"Id":"MZXLR3T2HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3248a4bea716","Type":"nvme"},{"Id":"MZXLR6T4HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Type":"nvme"},{"Id":"MZXLR1T9HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3948cda93afa","Type":"nvme"},{"Id":"MZXLR3T8HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3848df400867","Type":"nvme"},{"Id":"MZXLR960HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3936-3048d2d64915","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:06:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK7825Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"MPK7825Q"}],"SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"058d8510e4c84af39df1c07ce8b9aed5"}]},{"ProductId":"0c95f7c054f047b69fbfe7c93264a982","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3280064","DateModified":"2025-11-15T10:35:21","FileList":["cp068757.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG06scHPD9.REL"],"MD5Sum":"9a2b2cd933b1cb028acbfecafafe3e5e","Name":"cp068757.exe","Release":"2025-11-15T10:30:40","Revision":"H","SHA1Sum":"c5556e20e4d511de3fed10f8293d1becb63e6d68","SHA256Sum":"db528426cdce592b369e2bc13677c63c7d9191c827eb28148babdc156b938f1f","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000JWJRQおよび MB006000JWJRPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000JWJRQ","TargetGUID":"4d2340a5-3042-3830-3030-304a574a5251","Type":"sas"},{"Id":"MB006000JWJRP","TargetGUID":"4d2340a5-3042-3630-3030-304a574a5250","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T09:17:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"76ebd18092bc4839b75f22e8669eb8cc"}]},{"ProductId":"6a808075e9fa4bc19e7d11fd17511784","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;MPK78H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;MPK78H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"27553812","DateModified":"2025-03-06T10:57:47","FileList":["/CP065984_BUILD_12.data","/CP065984.vmexe64","/CP065984.vmfile","/CP065984_VMw.zip","/CP065984.xml","/payload.json","/CP065984_VMw.zip/index.xml","/CP065984_VMw.zip/vendor-index.xml","/CP065984_VMw.zip/metadata.zip","/CP065984_VMw.zip/vib20/CP065984/HPE_bootbank_CP065984_MPK78H5Q.12-8.0.0.20613240.vib","/CP065984_VMw.zip/metadata.zip/vendor-index.xml","/CP065984_VMw.zip/metadata.zip/vmware.xml","/CP065984_VMw.zip/metadata.zip/vibs/CP065984--20902355285946957.xml","/CP065984_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065984_MPK78H5Q.12-8.0.0.20613240.xml"],"MD5Sum":"f34ec795c48ebbc148de235c8008cafc","Name":"CP065984.zip","Release":"2025-03-06T10:56:56","Revision":"B","SHA1Sum":"9c5e5cfd0f2acb32b11c0353b31920dbd38d5ed4","SHA256Sum":"06689038d987ab449f67f46f4f960d6f20e4542be2f3398e60ed044940fd49cf","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17"],"TypeOfChange":"2","Version":"MPK78H5Q","VibList":[{"Name":"CP065984","Version":"MPK78H5Q.12-8.0.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXL515THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3135-54486d0092b3","Type":"nvme"},{"Id":"MZXL512THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3132-544895b51a17","Type":"nvme"},{"Id":"MZXL57T6HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3754-364820f1a5c1","Type":"nvme"},{"Id":"MZXL56T4HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3654-34482ab7fb8f","Type":"nvme"},{"Id":"MZXL53T8HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-38483310a47b","Type":"nvme"},{"Id":"MZXL53T2HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-324884d9e9f5","Type":"nvme"},{"Id":"MZXL51T6HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-36487a9b1618","Type":"nvme"},{"Id":"MZXL5800HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3830-3048d90154e8","Type":"nvme"},{"Id":"MZXL51T9HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-3948e450274f","Type":"nvme"},{"Id":"MZXL5960HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3936-304894dc03d2","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:18:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>発生する可能性がある修正不可能なマシンチェック例外(UMCE)の問題を修正しました。</li><li>詳しくは、HPEカスタマーアドバイザリ： <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"}],"SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"85cbb20de5d1424bacf3b788a8ce9163"}]},{"ProductId":"b5e0206ca4e94cf29c84aaeea6edefa1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV&nbsp; Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV&nbsp; Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4556800","DateModified":"2025-08-03T01:37:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-1.1/CP067337.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-1.1/KAPM6ALFHPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067337.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067337.scexe"],"MD5Sum":"f205ce894ef1ec6ebe403364a15fed8a","Name":"firmware-hdd-8f501d6cf1_0HPD4-1.1_amd64.deb","Release":"2025-08-03T06:28:29","Revision":"","SHA1Sum":"e05eb2b5e271bdaba765303cfe23cc3309646491","SHA256Sum":"fe9119883838094a979ada122a8226806987a817bd1bcbe0e4210f166146ec7a","Size":"4MB","TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP041670.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO003840XZCLT","TargetGUID":"562340a5-304f-3330-3834-30585a434c54","Type":"sas"},{"Id":"MO001600XZCLV","TargetGUID":"4d2340a5-304f-3130-3630-30585a434c56","Type":"sas"},{"Id":"MO000800XZCLQ","TargetGUID":"4d2340a5-304f-3030-3830-30585a434c51","Type":"sas"},{"Id":"VO007680XZCMB","TargetGUID":"562340a5-304f-3730-3638-30585a434d42","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:11:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a738a86f08dd4a2cb13d6a325c7c2409"}]},{"ProductId":"96853662d13b4def814a5c153a747271","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"}],"Files":[{"Bytes":"4539272","DateModified":"2025-11-16T13:07:13","FileList":["cp068742.xml","cpqsetup.exe","HVLAnAsseFD2.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"f27e51903e5c9b439ad83c2f6232fb68","Name":"cp068742.exe","Release":"2025-11-16T13:00:51","Revision":"G","SHA1Sum":"95f34f8d1e44c9ec6ca7410de5b9014020b4a688","SHA256Sum":"21ade002ab63f6d15254406fc07caac6b06cdfac805569a79239b04bd7b454e8","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB004000JWKGUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000JWKGU","TargetGUID":"4d2340a5-3042-3430-3030-304a574b4755","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T07:17:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4df2d8b6de9b405dab609becc2588452"}]},{"ProductId":"3d1400a6e0204fb498134f7e6e3f374a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB001000GWJAN、MB002000GWFWA および MB004000GWFWB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3644272","DateModified":"2025-11-15T15:16:21","FileList":["cp068754.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TATCATSATAG1.rel"],"MD5Sum":"8134746ac805a21f2c188e2ee02f286e","Name":"cp068754.exe","Release":"2025-11-15T15:11:39","Revision":"K","SHA1Sum":"e69ff50e88568f5169b0c6cfa353b77d81d505bc","SHA256Sum":"bd82062a5d295162781206cd34819a6bf393bbfe0a3b1c3bb9b228f30007649b","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000GWFWB","TargetGUID":"4d2340a5-3042-3430-3030-304757465742","Type":"sata"},{"Id":"MB002000GWFWA","TargetGUID":"4d2340a5-3042-3230-3030-304757465741","Type":"sata"},{"Id":"MB001000GWJAN","TargetGUID":"4d2340a5-3042-3130-3030-3047574a414e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:48:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9dc1ac030cb645d690837655164b9aea"}]},{"ProductId":"106244d003374fa49cfd57be5dd5767c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4579276","DateModified":"2025-08-02T19:57:04","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-1.1/CP067353.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-1.1/SCIMARRNESD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067353.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067353.scexe"],"MD5Sum":"0ba4c1b13e05f653d3577a0f0317cd44","Name":"firmware-hdd-ae6b41e855_0HPD8-1.1_amd64.deb","Release":"2025-08-03T00:51:02","Revision":"","SHA1Sum":"9d966cc74a10b261cc6eee83c6d6280519e349aa","SHA256Sum":"304ee97720bf7990dbfd5e4c2fd305c05002ea77c11e92e1876fb5a4e656b56e","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP043258.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000JWWQN","TargetGUID":"4d2340a5-3042-3630-3030-304a5757514e","Type":"sas"},{"Id":"MB008000JWWQP","TargetGUID":"4d2340a5-3042-3830-3030-304a57575150","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:45:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul>","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"580ab6d3564a4a7aa4bf1fd841b81106"}]},{"ProductId":"88920b6128524213bc79e665d9b3a53b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for the HPE QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2022 and Windows Server 2025."},{"Lang":"cn","Value":"This Component Package contains the drivers for the HPE QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、HPE QLogic NX2 10/20 GbEマルチファンクションGigabitサーバーアダプタードライバーfor Windows Server 2022およびWindows Server 2025が含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This component contains the following drivers:</p><ul><li>&nbsp;10/20 Gigabit Ethernet VBD Driver 7.13.221.0</li><li>&nbsp;iSCSI Offload Driver 7.14.19.0</li><li>&nbsp;Unified iSCSI Crash Dump Driver 7.13.7.0</li><li>&nbsp;Network Adapter NDIS VBD Client 7.13.220.0&nbsp;</li><li>&nbsp;FCoE Offload driver&nbsp;7.14.25.0</li><li>&nbsp;FCoE Crash Dump Driver 7.13.8.0</li></ul>"},{"Lang":"ja","Value":"<p>このコンポーネントは、以下のドライバーを含みます。</p><ul><li> 10/20 Gigabit Ethernet VBDドライバー7.13.221.0</li><li> iSCSIオフロードドライバー7.14.19.0</li><li> 統合iSCSIクラッシュダンプドライバー7.13.7.0</li><li> ネットワークアダプターNDIS VBDクライアント7.13.220.0 </li><li> FCoEオフロードドライバー7.14.25.0</li><li> FCoEクラッシュダンプドライバー7.13.8.0</li></ul>"},{"Lang":"cn","Value":"<p>This component contains the following drivers:</p><ul><li>&nbsp;10/20 Gigabit Ethernet VBD Driver 7.13.221.0</li><li>&nbsp;iSCSI Offload Driver 7.14.19.0</li><li>&nbsp;Unified iSCSI Crash Dump Driver 7.13.7.0</li><li>&nbsp;Network Adapter NDIS VBD Client 7.13.220.0&nbsp;</li><li>&nbsp;FCoE Offload driver&nbsp;7.14.25.0</li><li>&nbsp;FCoE Crash Dump Driver 7.13.8.0</li></ul>"}],"Files":[{"Bytes":"3462504","DateModified":"2025-11-14T03:46:22","FileList":["bcm10ginstaller.dll","bnxfcdo.sys","bnxfcdo_release.txt","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxfcoe_release.txt","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp069562.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys","qnxcdo_release.txt"],"MD5Sum":"1a9b988fef371f4bfbb5d730290cda4d","Name":"cp069562.exe","Release":"2025-11-14T03:29:11","Revision":"C","SHA1Sum":"cfe422f523e8126666565d08b4eec0bf12fca554","SHA256Sum":"77d97e35082bd43a7f06e38b6f57b0f0a2b343f58a6f7e09577425d332584895","Size":"3MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"TypeOfChange":"1","Version":"7.13.221.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbE マルチファンクションドライバーfor Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AD","SubDev":"2231","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ad103c2231","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T09:16:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Add Windows Server 2025 support.</p>","Fixes":"<p>This product resolves possible memory leak found in code scanning.</p>","Lang":"en"},{"Enhancements":"<p>Windows Server 2025のサポートを追加</p>","Fixes":"<p>この製品は、コードスキャンで発見される可能性のあるメモリリークを解決します。</p>","Lang":"ja"},{"Enhancements":"<p>Add Windows Server 2025 support.</p>","Fixes":"<p>This product resolves possible memory leak found in code scanning.</p>","Lang":"cn"}],"Version":"7.13.221.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Local 24H2 をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"cn"}],"Version":"7.13.221.0"}],"SWKeys":[{"Name":"evbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4cf57e3d1f7b41a89f2a4e1fbd4d11fb"}]},{"ProductId":"1b34555075d144b0bde6e5495e920e7c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE "},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4601336","DateModified":"2025-08-03T02:09:50","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-1.1/CP067346.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-1.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067346.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067346.scexe"],"MD5Sum":"49b4d3fbec7ec9c6de4c105141eb8ed7","Name":"firmware-hdd-10385ef3e6_0HPD2-1.1_amd64.deb","Release":"2025-08-03T07:03:12","Revision":"","SHA1Sum":"6a20aaaac3424c5e76f69e5d32b9e050a6f07dfe","SHA256Sum":"58a8e4f128b280c6f2a7751d4d22ec2f498ef2b0aa0ead64a08670ae7d7d6d9a","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041452.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JWRTH","TargetGUID":"4d2340a5-3042-3431-3030-304a57525448","Type":"sas"},{"Id":"MB012000JWRTF","TargetGUID":"4d2340a5-3042-3231-3030-304a57525446","Type":"sas"},{"Id":"MB010000JWRTE","TargetGUID":"4d2340a5-3042-3031-3030-304a57525445","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:38:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.&nbsp;</li></ul>","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ddcb3a45198f44f5b1a653d1e818b11d"}]},{"ProductId":"630e644160fa42ef980745ef1697fa39","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB012000JZYVN、MB014000JZYVP、MB016000JZYVQ、MB018000JYCLK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improves performance in certain file systems and implements fixes for several of the previous firmware&rsquo;s shortcomings.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improves performance in certain file systems and implements fixes for several of the previous firmware&rsquo;s shortcomings.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6021291","DateModified":"2025-09-17T11:48:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1/CP068867.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1/TAMG09scHPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068867.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068867.scexe"],"MD5Sum":"704fdf79b08cbbc53198b613e1e1334c","Name":"firmware-hdd-87b796d9ae-HPD4-5.1.x86_64.rpm","Release":"2025-09-17T16:39:05","Revision":"E","SHA1Sum":"87ea5e1e058b5d9d7360d4766340d4e107384108","SHA256Sum":"bd3f9ecf8aa60c0a13c960c4de115476fa1f50a6c2be4d3287f984d330bcd07b","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQおよびMB018000JYCLKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB012000JZYVN","TargetGUID":"4d2340a5-3042-3231-3030-304a5a59564e","Type":"sas"},{"Id":"MB014000JZYVP","TargetGUID":"4d2340a5-3042-3431-3030-304a5a595650","Type":"sas"},{"Id":"MB016000JZYVQ","TargetGUID":"4d2340a5-3042-3631-3030-304a5a595651","Type":"sas"},{"Id":"MB018000JYCLK","TargetGUID":"4d2340a5-3042-3831-3030-304a59434c4b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T20:17:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ea370f6467884df19200238f71a7c251"}]},{"ProductId":"bd2780f798b64cefbb3916c847ffd755","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.09"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.09"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.09"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.09"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターをアップグレートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7948655","DateModified":"2025-12-02T11:45:38","FileList":["/CP068324_BUILD_13.data","/CP068324.vmexe","/CP068324.vmexe64","/CP068324.vmfile","/CP068324_VMw.zip","/CP068324.xml","/payload.json","/CP068324_VMw.zip/index.xml","/CP068324_VMw.zip/vendor-index.xml","/CP068324_VMw.zip/metadata.zip","/CP068324_VMw.zip/vib20/CP068324/HPE_bootbank_CP068324_2025.11.01.13-8.0.0.20613240.vib","/CP068324_VMw.zip/metadata.zip/vendor-index.xml","/CP068324_VMw.zip/metadata.zip/vmware.xml","/CP068324_VMw.zip/metadata.zip/vibs/CP068324-2569958675708840853.xml","/CP068324_VMw.zip/metadata.zip/bulletins/Smart-Component-CP068324_2025.11.01.13-8.0.0.20613240.xml"],"MD5Sum":"2d746abd34d0c1ef13fc33da24a2fcb1","Name":"CP068324.zip","Release":"2025-12-02T11:41:51","Revision":"","SHA1Sum":"08ec8780a7ede06174278aa5ace8f69f3b1c4423","SHA256Sum":"6f16f8ff5f08fafb59d27fa45b218f5ae435b3e3be8d9e03c222ead819d72f9e","Size":"7MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2025.11.01","VibList":[{"Name":"CP068324","Version":"2025.11.01.13-8.0.0.20613240"}]}],"Installation":{"Command":"hpsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />Offline:</strong></p><ul><li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li></ul><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li><li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li><li>From the same directory, unzip the Smart Component.<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li><li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>To perform the standalone installation, execute the command:</li><li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li><li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:<ul><li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li></ul></li><li>To perform standalone installation of the firmware,Execute the command:<ul><li>./ Execute_Component</li></ul></li><li>Follow the directions given by the Smart Component</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host</li><li>Reboot your system, if required, for the firmware update to take effect</li></ul>"},{"Lang":"ja","Value":"<p><strong>HP Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />オフライン：</strong></p><ul><li>Service Pack ProLiantオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます</li></ul><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデートするESXiホストのIPまたはDNSアドレスを入力するか（ESXiホストがGen9サーバーの場合）、ESXiホストのiLOのIPまたはDNSアドレスを入力します（サーバーがGen10以上の場合）</li><li>Gen9/Gen10以上に基づいてESXiホスト/iLO認証情報（rootまたは管理者のユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください：</strong></p><ul><li>vSphereクライアントにログインします。</li><li>インベントリツリーのサーバーまたはクラスターを選択します。</li><li>HPE Insight Managementタブをクリックします。</li><li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li></ul><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>ESXiホスト上のTech Support Modeを有効にします。</li><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>Smartコンポーネント（CPxxxxxx.zip）を一時ディレクトリに置きます。</li><li>同じディレクトリからSmartコンポーネントをunzipします。<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>Smartコンポーネントには、ファームウェアのインストールを実行するためにインストールする必要のあるVIBで構成されたCPxxxxx_VMw.zipが含まれています</li><li>CPxxxxxx_VMw.zipファイルが実行可能であることを確認します。次のコマンドを実行します：<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>スタンドアロンのインストールを行うために、次のコマンドを実行します：</li><li>esxcli software vib install -d /<path_of_CPxxxxxx_VMw.zip>/CPxxxxxx_VMw.zip</li><li>インストールが完了したら、ディレクトリを/opt/Smart_Component/<CPxxxxxx>に変更します。次のコマンドを実行します：<ul><li>cd /opt/Smart_Component/<CPxxxxxx></li></ul></li><li>ファームウェアのスタンドアロンのインストールを行うために、次のコマンドを実行します：<ul><li>./ Execute_Component</li></ul></li><li>Smartコンポーネントの指示に従います。</li><li>ログアウトします。</li><li>ESXiホスト上のTech Support Modeを無効にします。</li><li>必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPEファームウェアフラッシュfor QLogicファイバーチャネルホストバスアダプター for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T07:05:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">アダプター</p></td><td><p dir=\"LTR\">速度</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">ファームウェア</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">ブートBIOS</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBデュアルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBシングルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.11.01"}],"SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"353b02f3101d47b4ae035de7c8327a0a"}]},{"ProductId":"1fab72b09ffc46b88aa5f81c9be3d475","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3589104","DateModified":"2025-07-31T10:43:23","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-1.1/CP067320.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-1.1/K401HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067320.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067320.scexe"],"MD5Sum":"012595efae294ba83a94f909b2936165","Name":"firmware-hdd-492a9952f6_0HPG5-1.1_amd64.deb","Release":"2025-07-31T15:37:22","Revision":"","SHA1Sum":"5bbc25362cb5836c9949daaaf4cc4fe544643538","SHA256Sum":"3a28fe38e990471f25e4bb6b18d86935be45f04f91f3a60f4ef51e21168eed8e","Size":"3MB","TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"CP041497.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK003840GWTHD","TargetGUID":"562340a5-304b-3330-3834-304757544844","Type":"sata"},{"Id":"VK001920GWTHC","TargetGUID":"562340a5-304b-3130-3932-304757544843","Type":"sata"},{"Id":"VK000960GWTHB","TargetGUID":"562340a5-304b-3030-3936-304757544842","Type":"sata"},{"Id":"VK000480GWTHA","TargetGUID":"562340a5-304b-3030-3438-304757544841","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:19:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f41a767438d14f2893b0069a9803a423"}]},{"ProductId":"7db6f792355b49a58fc4f82d6bbbdd99","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U32_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33613325","DateModified":"2026-01-14T09:25:11","FileList":["payload.json","U32_3.62_01_09_2026.signed.flash","U32_3.62_01_09_2026.xml"],"MD5Sum":"313103deedffc1308c5bf793efacfeb3","Name":"U32_3.62_01_09_2026.fwpkg","Release":"2026-01-14T09:21:55","Revision":"","SHA1Sum":"41ec67e3cf93e02d89c592c4b3fbcb395df9a800","SHA256Sum":"25382b3f781f1596c6fe555b4d171e3dcffd8dcb540cb1410b7da78cdb606fa8","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL360 Gen10（U32）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL360 Gen10 (U32) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:25:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"ed13b4c84eff4d909a8f158d12fd9aed"}]},{"ProductId":"6ac4c1fb52734dc69d27fd9966ff92b4","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE Intel ixgbenアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.22.1.0</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;1.22.1.0</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.22.1.0</p>"}],"Files":[{"Bytes":"248964","DateModified":"2025-09-22T04:31:28","FileList":["/cp068938.xml","/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.zip","/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.zip/index.xml","/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.zip/vib20/ixgben/INT_bootbank_ixgben_1.22.1.0-1OEM.800.1.0.20613240.vib","/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/ixgben-8173943675925103199.xml","/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Intel-ixgben_1.22.1.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"66fbdded0d95cddbe34b389c3db885ca","Name":"cp068938.zip","Release":"2025-09-22T04:31:19","Revision":"","SHA1Sum":"f1334430049213a04936793ef39a1c796589418d","SHA256Sum":"a6a840e864453bea973878cc5ef552254b82014515ae5700a4b734117c7b4ee6","Size":"243KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"ixgben","Version":"1.22.1.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixgben Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE Intel ixgbenドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Intel ixgben Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"57ad","SubDev":"00FF","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad808600ff","Type":"pci","Ven":"8086"},{"Dev":"57B1","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57b180860003","Type":"pci","Ven":"8086"},{"Dev":"57AD","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad80860003","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T01:52:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now adds support for E610 device.</p>","Fixes":"<ul><li>Known issue: Firmware OROM version displays as &quot;0.0.0&quot; via &quot;ethtool -i&quot;.</li><li>Known issue: Firmware OROM version displays incorrectly via &quot;esxcli network nic get -n interface&quot;.</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品では、E610デバイスのサポートが追加されました。</p>","Fixes":"<ul><li>既知の問題: 「ethtool -i」を実行すると、ファームウェア OROM バージョンが「0.0.0」と表示されます。</li><li>既知の問題: 「esxcli network nic get -n interface」でファームウェアOROMバージョンが正しく表示されません。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now adds support for E610 device.</p>","Fixes":"<ul><li>Known issue: Firmware OROM version displays as &quot;0.0.0&quot; via &quot;ethtool -i&quot;.</li><li>Known issue: Firmware OROM version displays incorrectly via &quot;esxcli network nic get -n interface&quot;.</li></ul>","Lang":"cn"}],"Version":"2025.07.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"Intel-ixgben:1.22.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.22.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c0950df8df16430ba7d6622d2278741a"}]},{"ProductId":"7204c0f5c514445a87ae5a6c742f6a37","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.<br />* The previous web release i40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp;&nbsp; &nbsp;- The RPM package name was changed from (<strong>hp</strong>-i40e-kmp-default) to (i40e-kmp-default). Now we revert this change from (i40e-kmp-default) to (<strong>hp</strong>-i40e-kmp-default).<br />&nbsp;&nbsp; &nbsp;- The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-i40e-kmp-default and i40e-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install i40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e i40e-kmp-default and then install the updated RPM.</li></ul>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。<br />* 以前のWebリリースi40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-i40e-kmp-default）から（i40e-kmp-default）に変更されました。この変更を（i40e-kmp-default）から（<strong>hp</strong>-i40e-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-i40e-kmp-defaultとi40e-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにi40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e i40e-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</li></ul>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.<br />* The previous web release i40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp;&nbsp; &nbsp;- The RPM package name was changed from (<strong>hp</strong>-i40e-kmp-default) to (i40e-kmp-default). Now we revert this change from (i40e-kmp-default) to (<strong>hp</strong>-i40e-kmp-default).<br />&nbsp;&nbsp; &nbsp;- The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-i40e-kmp-default and i40e-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install i40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e i40e-kmp-default and then install the updated RPM.</li></ul>"}],"Files":[{"Bytes":"447514","DateModified":"2025-09-15T16:01:10","FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-i40e","./lib/modules/6.4.0-150600.21-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"MD5Sum":"d8b65a55eef643f0fd65e15611a12c9d","Name":"hp-i40e-kmp-default-2.28.10_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-09-15T15:54:13","Revision":"","SHA1Sum":"2b24ddf90eb179b25959da6281ec43ba9c550553","SHA256Sum":"5ef7c18b44d0f515aec4e74f215d8d4fc0ad79d1dfd01a6bf2a3817c69c59f5c","Size":"437KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"TypeOfChange":"1","Version":"2.28.10-1"},{"Bytes":"446321","DateModified":"2025-09-15T16:06:15","FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-i40e","./lib/modules/6.4.0-150700.51-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"MD5Sum":"2c7de2ce887d06038ee7a3acf0917998","Name":"hp-i40e-kmp-default-2.28.10_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-09-15T15:54:13","Revision":"","SHA1Sum":"fd372758f2716b23a6516112b9b8fc21fdf9df3d","SHA256Sum":"ad377ad77428ff4b01730db90aaa415c86a6901835872b9360e08e568683466c","Size":"435KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"TypeOfChange":"1","Version":"2.28.10-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel i40eドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T01:42:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VF can abuse of PF-VF Capability Exchange commands to enable/disable features and mess with state dependent command.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、VFがPF-VF Capability Exchangeコマンドを悪用して機能を有効化/無効化したり、状態依存のコマンドを混乱させたりする可能性がある問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VF can abuse of PF-VF Capability Exchange commands to enable/disable features and mess with state dependent command.</p>","Lang":"cn"}],"Version":"2.28.7-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.28.10-1"}],"SWKeys":[{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"929ac9cf30c840959bcc9f2a17f38195"}]},{"ProductId":"da9ff49af6c74b6d969bca700eb095c0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 10で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 10."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"447491","DateModified":"2025-09-15T15:33:26","FileList":["./etc/depmod.d/kmod-ixgbe.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/ixgbe/ixgbe.ko","./usr/share/doc/kmod-ixgbe","./usr/share/doc/kmod-ixgbe/COPYING","./usr/share/doc/kmod-ixgbe/README","./usr/share/doc/kmod-ixgbe/pci.updates","./usr/share/man/man7/ixgbe.7.gz","./usr/share/smartupdate/kmod-ixgbe/component.xml"],"MD5Sum":"9aa147f829c67ed002b700138834b8f8","Name":"kmod-ixgbe-6.2.5-1.rhel10u0.x86_64.rpm","Release":"2025-09-15T15:28:42","Revision":"","SHA1Sum":"2b5323937df171568d1ae7c713c153d9bf985404","SHA256Sum":"72680cba191f9e5c27d7bb6b0288893362d17cb478ac06dd87e21f0c6d582906","Size":"437KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec510c02b3"],"TypeOfChange":"1","Version":"6.2.5-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 10"},{"Lang":"ja","Value":"HPE Intel ixgbeドライバーfor Red Hat Enterprise Linux 10"},{"Lang":"cn","Value":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"57ad","SubDev":"00FF","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad808600ff","Type":"pci","Ven":"8086"},{"Dev":"57B1","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57b180860003","Type":"pci","Ven":"8086"},{"Dev":"57AD","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad80860003","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-12T09:36:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Red Hat Enterprise Server 10をサポートするための初回リリースです。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"cn"}],"Version":"6.1.5-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"6.2.5-1"}],"SWKeys":[{"Name":"kmod-ixgbe","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"0b5dc9efc4604d2395d6023c2563b518"}]},{"ProductId":"6847395ba4ef4b018475096e40729a70","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"VMware ESXi 9 Update 0 Mellanox mst driver for Mellanox devices"},{"Lang":"cn","Value":"VMware ESXi 9 Update 0 Mellanox mst driver for Mellanox devices"},{"Lang":"ja","Value":"VMware ESXi 9 Update 0 Mellanox mst driver for Mellanox devices"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"33093","DateModified":"2025-03-19T09:02:34","FileList":["/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip","/cp066257.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vib20/nmst/MEL_bootbank_nmst_4.31.0.150-1OEM.801.0.0.21495797.vib","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vibs/nmst--3413091292116279482.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797.xml"],"MD5Sum":"a2f1b309047483e90e11b2b580ebbe8f","Name":"cp066257.zip","Release":"2025-03-19T09:01:33","Revision":"","SHA1Sum":"044d3c4713c741ec8c17712e956f495c185f97ec","SHA256Sum":"82d6e7f70f1109ab25782f90a65439c727fe9c4d877a5cc59f6b1c2575b286fc","Size":"32KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.1"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299","20a6e8e4-bf33-4c71-a6bf-d9ecd0345028"],"TypeOfChange":"1","Version":"2025.03.17","VibList":[{"Name":"nmst","Version":"4.31.0.150-1OEM.801.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"},{"Lang":"cn","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"},{"Lang":"ja","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"net-mst kernel module driver component for VMware ESXi 9 Update 0"},{"Lang":"cn","Value":"net-mst kernel module driver component for VMware ESXi 9 Update 0"},{"Lang":"ja","Value":"net-mst kernel module driver component for VMware ESXi 9 Update 0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"8020","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c8020","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"801F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c801f","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F4","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f4","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F2","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f2","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f3","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"22F5","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f5","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f1","Type":"pci","Ven":"15b3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"0221","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101315900221","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-17T09:48:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 9&nbsp;Update 0&nbsp;only.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 9&nbsp;Update 0&nbsp;only.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 9&nbsp;Update 0&nbsp;only.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.17"}],"SWKeys":[{"Name":"nmst:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"Mellanox-NATIVE-NMST:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"I38","Model":"HPE ProLiant BL660c Gen9 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant BL460c Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"","Model":"HPE Apollo sx40 Server"},{"Family":"","Model":"HPE Apollo pc40 Server"},{"Family":"","Model":"HPE Apollo kl20 Server"},{"Family":"","Model":"HPE Apollo am35 Server"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"54ee325a61e84639be6b288cef1e89ee"}]},{"ProductId":"365d207e25654d61b3829f731965d204","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000600JWCPFおよびEH000900JWCPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6018886","DateModified":"2025-09-21T22:11:30","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/CP068929.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/SKESTEDD.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068929.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068929.scexe"],"MD5Sum":"65d42412ad42c616d8df05d9e20600ff","Name":"firmware-hdd-a05f29cef3-HPDD-4.1.x86_64.rpm","Release":"2025-09-22T02:58:57","Revision":"D","SHA1Sum":"2d9ed8425fecf3dbedf1830b11bd5c90d8e3dafa","SHA256Sum":"fab19de9378e1abc091abef651330298e984a6f6684a8c36167fd680ebdacf97","Size":"5MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"Installation":{"Command":"CP040712.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000600JWCPF","TargetGUID":"452340a5-3048-3030-3630-304a57435046","Type":"sas"},{"Id":"EH000900JWCPH","TargetGUID":"452340a5-3048-3030-3930-304a57435048","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:11:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDD"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log</li></ul>","Lang":"cn"}],"Version":"HPDD"}],"SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4d0081a2928643a98e1eabd433b2d539"}]},{"ProductId":"1bc921f76f2d48759522424a4aff4914","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U45_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11621496","DateModified":"2026-01-14T06:44:00","FileList":["cp070357.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U45_3.62_01_09_2026.signed.flash"],"MD5Sum":"e07ed333d5e1bcda59d7a8227e23a9af","Name":"cp070357.exe","Release":"2026-01-14T06:41:23","Revision":"","SHA1Sum":"e25eee40e9f8b525b351db63f85e25ac1f9c4ded","SHA256Sum":"36a4e150ada7845d76415a1b32907c4781f479372f1cbffee0902971d083f231","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:45:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"095dfd4b956941efb948badc2653119d"}]},{"ProductId":"a745e380a94147888b60792dcbb594a8","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v4.00 (01/09/2026)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33604923","DateModified":"2026-01-13T02:53:17","FileList":["A42_4.00_01_09_2026.signed.flash","A42_4.00_01_09_2026.xml","payload.json"],"MD5Sum":"ca41db8394d376cb94cd000bf5fab64b","Name":"A42_4.00_01_09_2026.fwpkg","Release":"2026-01-13T02:49:25","Revision":"","SHA1Sum":"749effd3c96ed11f053f85e2b91ee6d44ce084d9","SHA256Sum":"da638563c4772393e7d4bb8d1d556a696d090a7c8d2515c212421cab53934813","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"},{"Lang":"ja","Value":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus（A42）サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:39:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。</p><p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.92_11-27-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"74da516248ea426786d4219f64383afc"}]},{"ProductId":"19810cc433a442df903276a4b0c34598","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2019."},{"Lang":"ja","Value":"This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2019."},{"Lang":"cn","Value":"This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"2461456","DateModified":"2025-11-17T01:06:13","FileList":["cp068344.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"89ac7d6a28c4ceebbd44392db031b4a6","Name":"cp068344.exe","Release":"2025-11-17T00:52:28","Revision":"","SHA1Sum":"4948d01bbb1c3192b90ccb5b025b473431f75efd","SHA256Sum":"4f3db822fc0829e9d4955fe9b280f2593868fcaa09705e5501ec446aa67c23b4","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.7.26882.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox WinOF2 Driver for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"Mellanox WinOF2 Driver for Microsoft Windows Server 2019"},{"Lang":"cn","Value":"Mellanox WinOF2 Driver for Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30117","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30040","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30102","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30047","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30116","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30052","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0007","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30007","Type":"pci","Ven":"15B3"},{"Dev":"101E","SubDev":"0012","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30012","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-13T02:39:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"en"},{"Enhancements":"<p>Windows上のDOCAテレメトリライブラリに対するサポートが追加されました。</p>","Fixes":"<ul><li>この製品では、ファームウェアが機能していない場合にサスペンド/再開プロセス中にBSODが発生する可能性がある問題が修正されました。</li><li>この製品では、アダプターが無効化されている場合、マルチセグメントPCIマシン上で「Mlx5Cmd -Stat」が物理的な位置情報を誤って表示する問題を修正しました。</li><li>この製品では、イベント399に誤った情報が表示される問題が修正されました。</li><li>この製品は、VMQ/SR-IOVモードで動作するアダプター上でpktmonを有効化または無効化する際に、エラーイベント410および304が発生する問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Added support for the DOCA Telemetry Library on Windows.</p>","Fixes":"<ul><li>This product fixed an issue that could cause a BSOD during the suspend/resume process when the firmware is not functional.</li><li>This product fixed an issue where &quot;Mlx5Cmd -Stat&quot; displayed incorrect physical location information on multi-segment PCI machines when the adapter was disabled.</li><li>This product fixed an issue where Event 399 displayed incorrect information.</li><li>This product fixed an issue that triggered Error events 410 and 304 when enabling or disabling pktmon on an adapter operating in VMQ/SR-IOV mode.</li></ul>","Lang":"cn"}],"Version":"25.4.26768.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed an issue where the Relaxed Ordering feature was incorrectly disabled when using firmware versions newer than XX.36.2024.</p>","Lang":"cn"}],"Version":"25.7.26882.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"665a87f4c02a4ebe92c62a3c9866c192"}]},{"ProductId":"96fe9c5a9b9741d5bcf4ae73623359e0","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE 100GbE 1p QSFP28 MCX515A-CCAT Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"16_35_8002-MCX515A-CCA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101715900346","Version":"16.35.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor HPE Ethernet 100Gb 1ポートQSFP28 PCIe3 x16 MCX515A-CCATアダプター：HPE部品番号P31246-B21およびP31246-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported 1/10GbE Cables:</strong></p><ul><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; &nbsp;HPE BLc 10Gb SR SFP+ Opt</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BLc 10Gb LR SFP+ Opt</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 5m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adapter Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487649-B21 &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 0.5m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487652-B21 &nbsp;&nbsp; &nbsp;HPE BLc SFP+ 1m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487658-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 7m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP784A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m C-series Passive Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP785A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 5m C-series Passive Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP818A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1m B-series Active Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP819A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m B-series Active Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9150A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC SR Transceiver</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9151A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;J9152A&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC LRM Transceiver&nbsp;</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9281B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X242 10G SFP+ to SFP+ 1m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9283B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X242 10G SFP+ SFP+ 3m DAC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;JD096B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 1.2m DAC Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD097C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 3m DAD Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD096C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 1.2m DAC Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD095C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 0.65m DAC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ839A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 50m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ838A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 30m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ836A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 5m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ834A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ833A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 0.5m Multi-mode OM3 LC/LC FC Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;487652-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 1m 10GbE Copper Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;AP820A&nbsp;&nbsp; &nbsp; &nbsp;&nbsp; &nbsp;HPE 5m B-series Active Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;E3D93A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1.5m Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;E3D94A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 2m B-series Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;JG329A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 1m</li><li>10GBE&nbsp;&nbsp; &nbsp;JG330A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 3m</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP784A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m C-series Passive Copper SFP+ Cable</li></ul><p><strong>Validated and Supported 25 GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21 &nbsp;&nbsp; &nbsp;HPE QSFP 28 to SFP28 Adaptor</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844471-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 0.5m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844474-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 1m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844477-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 3m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844480-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 5m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 15m AOC Cable&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE QSFP+ SR4 100m (40G)</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG325B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ MPO SR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG325A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ MPO SR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG326A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 1m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG327A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 3m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG328A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 5m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG331A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE QSFP+ 40Gb Bi-Directional XCVR&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720205-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 7m AOC Cable &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720208-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 10m AOC Cable&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721070-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 7m Opt&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721073-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 10m Opt&nbsp;&nbsp;</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B25&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 7m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B24&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 5m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B21&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 1m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B22&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 2m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B23 &nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 3m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B23&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 3m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B24&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 5m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B25&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 10m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B26&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 15m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B27&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 20m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B28&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 30m</li><li>40GB/S&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720190-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ LC LR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B28&nbsp;&nbsp; &nbsp;HPE 30M FDR Quad Small Form Factor Pluggable InfiniBand Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Q7F11A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 40GbE QSFP28 SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670759-B23&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP passive copper cable, 1.5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B21&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 3m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B22&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B23&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 7m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B24&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 10m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B25&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 12m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B26&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 15m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B27&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 20m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B28&nbsp;&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 30m</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B21&nbsp;&nbsp; &nbsp;HPE 3 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B22&nbsp;&nbsp; &nbsp;HPE 5 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B23&nbsp;&nbsp; &nbsp;HPE 7 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B24&nbsp;&nbsp; &nbsp;HPE 10 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B25&nbsp;&nbsp; &nbsp;HPE 12 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B26&nbsp;&nbsp; &nbsp;HPE 15 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B27&nbsp;&nbsp; &nbsp;HPE 20 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B28&nbsp;&nbsp; &nbsp;HPE 30 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>40GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JL251A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ LC BiDi 100m MM XCVR</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40GbE QSFP+ BiDi XCVR</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845966-B21 &nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 MPO SR4 100m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845418-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;JL273A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 5M DAC Cable - 5m</li><li>100GBE&nbsp;&nbsp; &nbsp;JL271A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 1M DAC Cable - 1m</li><li>100GBE&nbsp;&nbsp; &nbsp;JL272A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 3M DAC Cable - 3m</li><li>100GbE&nbsp;&nbsp; &nbsp;845404-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 1m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;845402-B21&nbsp; &nbsp; HPE 100Gb QSFP28 to QSFP28 0.5m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;882251-B21&nbsp;&nbsp; &nbsp;HPE SY 100GE/4x25GE/4x32GFC QSFP28 XCVR</li></ul><p><strong>Note:&nbsp;</strong>Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされる1/10GbEケーブル：</strong></p><ul><li>1GbE/10GbE 455883-B21 HPE BLc 10Gb SR SFP+オプション</li><li>1GbE/10GbE 455886-B21 HPE BLc 10Gb LR SFP+オプション</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE 537963-B21 HPE BLc SFP+ 5m 10GbE銅線ケーブル</li><li>1GbE/10GbE    655874-B21        HPE QSFP/SFP+アダプターキット</li><li>10GbE        813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE        838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li><li>1GbE/10GbE    487649-B21         HPE BLc SFP+ 0.5m 10GbE銅ケーブル</li><li>1GbE/10GbE 487652-B21 HPE BLc SFP+ 1m 10GbE銅線ケーブル</li><li>1GbE/10GbE 487658-B21 HPE BLc SFP+ 7m 10GbE銅線ケーブル</li><li>1GbE/10GbE AP784A         HPE 3m CシリーズSFP+パッシブ銅線ケーブル</li><li>1GbE/10GbE AP785A        HPE 5m CシリーズSFP+パッシブ銅線ケーブル</li><li>1GbE/10GbE AP818A        HPE 1m BシリーズSFP+アクティブ銅線ケーブル</li><li>1GbE/10GbE AP819A        HPE 3m BシリーズSFP+アクティブ銅線ケーブル</li><li>1GbE/10GbE J9150A        HPE X132 10G SFP+ LC SRトランシーバー</li><li>1GbE/10GbE   J9151A        HPE X132 10G SFP+ LC LRトランシーバー</li><li>10GbE        J9152A         HPE X132 10G SFP+ LC LRMトランシーバー </li><li>1GbE/10GbE   J9281B        HPE X242 10G SFP+ to SFP+ 1m直接接続銅線ケーブル</li><li>1GbE/10GbE   J9283B        HPE X242 10G SFP+ SFP+ 3m DACケーブル</li><li>1GbE/10GbE   JD096B        HPE X240 10G SFP+ SFP+ 1.2m DACケーブル</li><li>10GbE        JD097C        HPE X240 10G SFP+ SFP+ 3m DADケーブル</li><li>10GbE        JD096C        HPE X240 10G SFP+ SFP+ 1.2m DACケーブル</li><li>10GbE        JD095C        HPE X240 10G SFP+ SFP+ 0.65m DACケーブル</li><li>1GbE/10GbE AJ839A        HPE 50mマルチモードOM3 LC/LC FCケーブル</li><li>1GbE/10GbE AJ838A        HPE 30mマルチモードOM3 LC/LC FCケーブル</li><li>1GbE/10GbE AJ836A        HPE 5mマルチモードOM3 LC/LC FCケーブル</li><li>1GbE/10GbE AJ834A        HPE 1mマルチモードOM3 LC/LC FCケーブル</li><li>1GbE/10GbE AJ833A        HPE 0.5mマルチモードOM3 LC/LC FCケーブル</li><li>10GBE        487652-B21    HPE BLc SFP+ 1m 10GbE銅ケーブル</li><li>10GBE        AP820A         HPE 5m BシリーズSFP+アクティブ銅線ケーブル</li><li>10GBE    E3D93A            HPE 1.5m SFP+銅線ケーブル</li><li>10GBE    E3D94A            HPE 2m BシリーズSFP+銅線ケーブル</li><li>10GBE    JG329A            HPE X240 40G QSFP+ to 4x10G SFP+ 1m</li><li>10GBE    JG330A            HPE X240 40G QSFP+ to 4x10G SFP+ 3m</li><li>1GbE/10GbE AP784A        HPE 3m CシリーズSFP+パッシブ銅線ケーブル</li></ul><p><strong>検証済みおよびサポートされる25 GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター</li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>25GbE    844471-B21    HPE 25Gb SFP28 to SFP28 0.5m DAC</li><li>25GbE    844474-B21    HPE 25Gb SFP28 to SFP28 1m DAC</li><li>25GbE    844477-B21    HPE 25Gb SFP28 to SFP28 3m DAC</li><li>25GbE    844480-B21    HPE 25Gb SFP28 to SFP28 5m DAC</li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC</li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC</li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー</li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE        720211-B21    HPE BLc 40G QSFP+ QSFP+ 15m AOCケーブル  </li><li>40GbE        721076-B21    HPE BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE        720187-B21    HPE QSFP+ SR4 100m (40G)</li><li>40GbE        JG325B        HPE X140 40G QSFP+ MPO SR4トランシーバー</li><li>40GbE        JG325A        HPE X140 40G QSFP+ MPO SR4トランシーバー</li><li>40GbE        JG326A        HPE X240 40G QSFP+ QSFP+ 1m DACケーブル</li><li>40GbE        JG327A        HPE X240 40G QSFP+ QSFP+ 3m DACケーブル</li><li>40GbE        JG328A        HPE X240 40G QSFP+ QSFP+ 5m DACケーブル</li><li>40GbE        JG331A        HPE X240 40G QSFP+ to 4x10G SFP+ 5m</li><li>40GbE        841716-B21    HPE QSFP+ 40Gb双方向XCVR  </li><li>40GbE        720205-B21    HPE BLc 40G QSFP+ QSFP+ 7m AOCケーブル  </li><li>40GbE        720208-B21    HPE BLc 40G QSFP+ QSFP+ 10m AOCケーブル  </li><li>40GbE        721070-B21    HPE BLc QSFP+ to 4x10G SFP+ AOC 7m Opt  </li><li>40GbE        721073-B21    HPE BLc QSFP+ to 4x10G SFP+ AOC 10m Opt  </li><li>QDR/FDR10    498385-B25    QDR/FDR10 InfiniBand QSFP銅ケーブル、7m</li><li>QDR/FDR10    498385-B24    QDR/FDR10 InfiniBand QSFP銅ケーブル、5m</li><li>QDR/FDR10    498385-B21    QDR/FDR10 InfiniBand QSFP銅ケーブル、1m</li><li>QDR/FDR10    498385-B22    QDR/FDR10 InfiniBand QSFP銅ケーブル、2m</li><li>QDR/FDR10    498385-B23     QDR/FDR10 InfiniBand QSFP銅ケーブル、3m</li><li>QDR/FDR10    498386-B23    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、3m</li><li>QDR/FDR10    498386-B24    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、5m</li><li>QDR/FDR10    498386-B25    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、10m</li><li>QDR/FDR10    498386-B26    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、15m</li><li>QDR/FDR10    498386-B27    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、20m</li><li>QDR/FDR10    498386-B28    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、30m</li><li>40GB/S        720190-B21    HPE BladeSystem c-Class 40Gb QSFP+ LC LR4トランシーバー</li><li>40GbE        670760-B28 HPE 30M FDR Quad Small Form Factor Pluggable InfiniBand光ケーブル</li><li>40GbE        Q7F11A        HPE Mシリーズ40GbE QSFP28 SR4 100mトランシーバー</li><li>40GbE        670759-B23    FDR InfiniBand QSFPパッシブ銅線ケーブル、1.5m</li><li>40GbE        670760-B21    FDR InfiniBand QSFPアクティブファイバーケーブル、3m</li><li>40GbE        670760-B22    FDR InfiniBand QSFPアクティブファイバーケーブル、5m</li><li>40GbE        670760-B23    FDR InfiniBand QSFPアクティブファイバーケーブル、7m</li><li>40GbE        670760-B24    FDR InfiniBand QSFPアクティブファイバーケーブル、10m</li><li>40GbE        670760-B25    FDR InfiniBand QSFPアクティブファイバーケーブル、12m</li><li>40GbE        670760-B26    FDR InfiniBand QSFPアクティブファイバーケーブル、15m</li><li>40GbE        670760-B27    FDR InfiniBand QSFPアクティブファイバーケーブル、20m</li><li>40GbE        670760-B28     FDR InfiniBand QSFPアクティブファイバーケーブル、30m</li><li>FDR        808722-B21 HPE 3 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B22 HPE 5 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B23 HPE 7 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B24 HPE 10 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B25 HPE 12 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B26 HPE 15 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B27 HPE 20 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B28 HPE 30 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>40GBE        JL251A         HPE X140 40G QSFP+ LC BiDi 100m MM XCVR</li><li>40GbE        841716-B21   HPE 40GbE QSFP+ BiDi XCVR</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21        HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21        HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3mダイレクトアタッチ銅線ケーブル</li><li>100GbE    845972-B21        HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GbE    845414-B21        HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GbE 845966-B21  HPE 100Gb QSFP28 MPO SR4 100m XCVR</li><li>100GbE    845418-B21        HPE 100Gb QSFP28 to 4x25Gb SFP28 5m DAC</li><li>100GBE    JL273A        HPE X240 100G QSFP28 5M DACケーブル - 5m</li><li>100GBE    JL271A         HPE X240 100G QSFP28 1M DACケーブル - 1m</li><li>100GBE    JL272A        HPE X240 100G QSFP28 3M DACケーブル - 3m</li><li>100GbE    845404-B21    HPE 100Gb QSFP28 to QSFP28 1mダイレクトアタッチ銅線ケーブル</li><li>100GBE    845402-B21    HPE 100Gb QSFP28 to QSFP28 0.5mダイレクトアタッチ銅線ケーブル</li><li>100GbE    882251-B21        HPE SY 100GE/4x25GE/4x32GFC QSFP28 XCVR</li></ul><p><strong>注記：</strong>このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported 1/10GbE Cables:</strong></p><ul><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; &nbsp;HPE BLc 10Gb SR SFP+ Opt</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BLc 10Gb LR SFP+ Opt</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 5m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adapter Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487649-B21 &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 0.5m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487652-B21 &nbsp;&nbsp; &nbsp;HPE BLc SFP+ 1m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487658-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 7m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP784A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m C-series Passive Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP785A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 5m C-series Passive Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP818A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1m B-series Active Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP819A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m B-series Active Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9150A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC SR Transceiver</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9151A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;J9152A&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC LRM Transceiver&nbsp;</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9281B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X242 10G SFP+ to SFP+ 1m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9283B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X242 10G SFP+ SFP+ 3m DAC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;JD096B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 1.2m DAC Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD097C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 3m DAD Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD096C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 1.2m DAC Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD095C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 0.65m DAC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ839A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 50m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ838A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 30m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ836A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 5m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ834A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ833A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 0.5m Multi-mode OM3 LC/LC FC Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;487652-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 1m 10GbE Copper Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;AP820A&nbsp;&nbsp; &nbsp; &nbsp;&nbsp; &nbsp;HPE 5m B-series Active Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;E3D93A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1.5m Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;E3D94A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 2m B-series Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;JG329A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 1m</li><li>10GBE&nbsp;&nbsp; &nbsp;JG330A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 3m</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP784A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m C-series Passive Copper SFP+ Cable</li></ul><p><strong>Validated and Supported 25 GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21 &nbsp;&nbsp; &nbsp;HPE QSFP 28 to SFP28 Adaptor</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844471-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 0.5m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844474-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 1m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844477-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 3m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844480-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 5m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 15m AOC Cable&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE QSFP+ SR4 100m (40G)</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG325B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ MPO SR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG325A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ MPO SR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG326A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 1m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG327A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 3m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG328A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 5m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG331A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE QSFP+ 40Gb Bi-Directional XCVR&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720205-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 7m AOC Cable &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720208-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 10m AOC Cable&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721070-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 7m Opt&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721073-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 10m Opt&nbsp;&nbsp;</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B25&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 7m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B24&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 5m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B21&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 1m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B22&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 2m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B23 &nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 3m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B23&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 3m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B24&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 5m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B25&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 10m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B26&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 15m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B27&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 20m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B28&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 30m</li><li>40GB/S&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720190-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ LC LR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B28&nbsp;&nbsp; &nbsp;HPE 30M FDR Quad Small Form Factor Pluggable InfiniBand Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Q7F11A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 40GbE QSFP28 SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670759-B23&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP passive copper cable, 1.5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B21&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 3m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B22&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B23&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 7m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B24&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 10m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B25&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 12m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B26&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 15m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B27&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 20m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B28&nbsp;&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 30m</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B21&nbsp;&nbsp; &nbsp;HPE 3 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B22&nbsp;&nbsp; &nbsp;HPE 5 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B23&nbsp;&nbsp; &nbsp;HPE 7 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B24&nbsp;&nbsp; &nbsp;HPE 10 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B25&nbsp;&nbsp; &nbsp;HPE 12 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B26&nbsp;&nbsp; &nbsp;HPE 15 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B27&nbsp;&nbsp; &nbsp;HPE 20 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B28&nbsp;&nbsp; &nbsp;HPE 30 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>40GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JL251A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ LC BiDi 100m MM XCVR</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40GbE QSFP+ BiDi XCVR</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845966-B21 &nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 MPO SR4 100m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845418-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;JL273A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 5M DAC Cable - 5m</li><li>100GBE&nbsp;&nbsp; &nbsp;JL271A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 1M DAC Cable - 1m</li><li>100GBE&nbsp;&nbsp; &nbsp;JL272A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 3M DAC Cable - 3m</li><li>100GbE&nbsp;&nbsp; &nbsp;845404-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 1m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;845402-B21&nbsp; &nbsp; HPE 100Gb QSFP28 to QSFP28 0.5m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;882251-B21&nbsp;&nbsp; &nbsp;HPE SY 100GE/4x25GE/4x32GFC QSFP28 XCVR</li></ul><p><strong>Note:&nbsp;</strong>Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"5654729","DateModified":"2025-10-09T08:07:21","FileList":["16_35_8002-MCX515A-CCA_HPE_Ax.pldm.signed","16_35_8002-MCX515A-CCA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"616497c4bc2efb350cf5cc9149487521","Name":"16_35_8002-MCX515A-CCA_HPE_Ax.pldm.fwpkg","Release":"2025-10-09T08:03:41","Revision":"","SHA1Sum":"9e17c188df472733529e86c22b1374ee0977b2ad","SHA256Sum":"fb65bf0a8650bda591636ba25bc72e107defb5cfc09aa3172cccd4066b6cace7","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715900346"],"TypeOfChange":"1","Version":"16.35.8002"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ (FWPKG) for HPE Ethernet 100Gb 1ポートQSFP28 PCIe3 x16 MCX515A-CCATアダプター：HPE部品番号P31246-B21およびP31246-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-30T11:36:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン16.35.4506で修正されました。</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"16.35.4506"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"16.35.8002"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX515A-CCAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"a81c9cecac1b4a8fa8d6901c0532a8ae"}]},{"ProductId":"3af72b6238454de589e484681033279c","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE e920 10GbE 2p Network Mezzanine Kit","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101f1590012c","Version":"26.43.1014"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for HPE Edgeline e920 ConnectX-6Lx 10Gb 2-port Mezzanine Adapter : HPE part number P40899-B21"},{"Lang":"ja","Value":"Mellanox HPE signed PLDM Firmware Package for HPE Edgeline e920 ConnectX-6Lx 10Gb 2-port Mezzanine Adapter : HPE part number P40899-B21"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for HPE Edgeline e920 ConnectX-6Lx 10Gb 2-port Mezzanine Adapter : HPE part number P40899-B21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"6707569","DateModified":"2026-01-22T05:01:15","FileList":["26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.signed","26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.xml","payload.json"],"MD5Sum":"cf2c6b783fc8f02ff6d381dd7edc4ef2","Name":"26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.fwpkg","Release":"2026-01-22T04:58:23","Revision":"","SHA1Sum":"d8581abec6fc550febdab1bf76155b31fc682b72","SHA256Sum":"8414e0000cab2de2793f4eb21f363d1466c5967fbd40b95a1695bd7a4b0eda7f","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f1590012c"],"TypeOfChange":"1","Version":"26.43.1014"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package (FWPKG) for  HPE Edgeline e920 ConnectX-6Lx 10Gb 2-port Mezzanine Adapter :  HPE part number P40899-B21"},{"Lang":"ja","Value":"Mellanox Firmware Package (FWPKG) for  HPE Edgeline e920 ConnectX-6Lx 10Gb 2-port Mezzanine Adapter :  HPE part number P40899-B21"},{"Lang":"cn","Value":"Mellanox Firmware Package (FWPKG) for  HPE Edgeline e920 ConnectX-6Lx 10Gb 2-port Mezzanine Adapter :  HPE part number P40899-B21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101F","SubDev":"012C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f1590012c","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-21T22:42:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.41.1001:</strong></p><ul><li>Implemented Deterministic Random Bit Generator (DRBG) algorithm on top of firmware TRNG (the source for raw data input) in accordance with NIST SP800-90A.</li><li>Added support for vDPA virtual queue state change from suspend to ready, and discrete mkey for descriptor. vDPA Live Migration uses these two new capabilities to reduce downtime since vq can go back to ready state for traffic and descriptor-only-mkey can help reduce mkey mapping time.</li><li>Added a new NVConfig option to copy AR bit from the BTH header to the DHCP header.</li><li>Added the option to provide field&#39;s offset and length in Steering add_action option.</li><li>Added support for steering match on packet l4_type through FTG/FTE.</li><li>Extended Flex Parser merge mechanism to support hardware capabilities.</li><li>Enabled the option to disable the native parser when the parse graph node is configured with the same conditions.</li><li>Added support for father/son headers parsing.</li><li>Added support for tunnel_offload in LRO.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.41.1001:</strong></p><ul><li>Traffic failure occurred when modifying the VIRTIO_NET_F_MRG_RXBUF bit for the VDPA device during traffic.</li><li>The second mkey index returned even if it was not set in the creation of the virtio q when querying virtio q object.</li><li>Traffic loss occurred after performing Live Migration with virtio vq &quot;frozen-ready&quot; feature.</li></ul><p>Note: When the traffic load is high, and the vq frozen-ready cap is on, traffic loss might still be experienced after modifying the vq from suspend to ready mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュリティ強化の機能強化 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。<br /> </p><p><strong>バージョン26.41.1001には、以下の新機能と変更が含まれます。</strong></p><ul><li>NIST SP800-90Aに準拠し、ファームウェアTRNG（rawデータ入力のソース）に加えて決定論的ランダムビットジェネレーター（DRBG）アルゴリズムを実装しました。</li><li>vDPAの仮想キュー状態のサスペンドからレディへの変更と、ディスクリプタのためのディスクリートmkeyのサポートを追加しました。 vDPA Live Migrationは、vqがトラフィックのためにレディ状態に戻ることができ、記述子のみのmkeyがmkeyのマッピング時間を短縮するのに役立つため、ダウンタイムを短縮するためにこれら2つの新しい機能を使用します。</li><li>BTHヘッダーからDHCPヘッダーにARビットをコピーするための新しいNVConfigオプションが追加されました。</li><li>ステアリングのadd_actionオプションでフィールドのオフセットと長さを指定するためのオプションが追加されました。</li><li>FTG/FTEを介したパケットl4_typeでのステアリングマッチのサポートが追加されました。</li><li>ハードウェア機能をサポートするためにFlex Parserマージメカニズムを拡張しました。</li><li>解析グラフノードが同じ条件で構成されている場合にネイティブパーサーを無効にするオプションを有効にしました。</li><li>father/sonヘッダー解析のサポートが追加されました。</li><li>LROにtunnel_offloadのサポートが追加されました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン26.41.1001で修正されました：</strong></p><ul><li>トラフィック中にVDPAデバイスのVIRTIO_NET_F_MRG_RXBUFビットを変更すると、トラフィック障害が発生しました。</li><li>virtio qオブジェクトを照会するときに、virtio qの作成時に設定されていなくても、2番目のmkeyインデックスが返されます。</li><li>virtio vqの「frozen-ready」機能を使用してライブマイグレーションを実行した後、トラフィック損失が発生しました。</li></ul><p>注記：トラフィック負荷が高く、vqのフリーズ準備完了キャップがオンの場合、vqを一時停止モードから準備完了モードに変更した後でもトラフィック損失が発生する可能性があります。</p>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.41.1001:</strong></p><ul><li>Implemented Deterministic Random Bit Generator (DRBG) algorithm on top of firmware TRNG (the source for raw data input) in accordance with NIST SP800-90A.</li><li>Added support for vDPA virtual queue state change from suspend to ready, and discrete mkey for descriptor. vDPA Live Migration uses these two new capabilities to reduce downtime since vq can go back to ready state for traffic and descriptor-only-mkey can help reduce mkey mapping time.</li><li>Added a new NVConfig option to copy AR bit from the BTH header to the DHCP header.</li><li>Added the option to provide field&#39;s offset and length in Steering add_action option.</li><li>Added support for steering match on packet l4_type through FTG/FTE.</li><li>Extended Flex Parser merge mechanism to support hardware capabilities.</li><li>Enabled the option to disable the native parser when the parse graph node is configured with the same conditions.</li><li>Added support for father/son headers parsing.</li><li>Added support for tunnel_offload in LRO.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.41.1001:</strong></p><ul><li>Traffic failure occurred when modifying the VIRTIO_NET_F_MRG_RXBUF bit for the VDPA device during traffic.</li><li>The second mkey index returned even if it was not set in the creation of the virtio q when querying virtio q object.</li><li>Traffic loss occurred after performing Live Migration with virtio vq &quot;frozen-ready&quot; feature.</li></ul><p>Note: When the traffic load is high, and the vq frozen-ready cap is on, traffic loss might still be experienced after modifying the vq from suspend to ready mode.</p>","Lang":"cn"}],"Version":"26.41.1001"},{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.43.1014:</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 26.43.1014:</strong></p>","Lang":"en"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.43.1014:</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 26.43.1014:</strong></p>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.43.1014:</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 26.43.1014:</strong></p>","Lang":"cn"}],"Version":"26.43.1014"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_E920CX6LX_MEZZ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"3ddc1bf7dbbb4a3f823e4a876f8d79ed"}]},{"ProductId":"7998b80f937f47828d4693eb2d620eec","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作するIntel i40ea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1245736","DateModified":"2025-11-16T10:26:22","FileList":["cp069538.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"d54af0d87996f75a4f842910d66678fa","Name":"cp069538.exe","Release":"2025-11-16T10:12:16","Revision":"B","SHA1Sum":"f76805dc65ce54bdadad9e58abcf678cbbe7eba5","SHA256Sum":"506a5e8cbb0b2cd8dd4e50acefb7227ddc97e9b523443a9017e665dc7c9eaec8","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.22.84.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i40ea Driver for Windows Server 2025"},{"Lang":"ja","Value":"Intel i40eaドライバーfor Windows Server 2025"},{"Lang":"cn","Value":"Intel i40ea Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860000","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103C0000","Type":"pci","Ven":"8086"},{"Dev":"158A","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-158A15900000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"cn"}],"Version":"1.22.84.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"cn"}],"Version":"1.22.84.0"}],"SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"9ea3595ca30346e2b4f4795669106964"}]},{"ProductId":"f2f901fd357f4c6692fae66dcbbb15ed","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U44_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.72 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16822389","DateModified":"2026-01-13T08:16:19","FileList":["payload.json","U44_3.72_01_09_2026.signed.flash","U44_3.72_01_09_2026.xml"],"MD5Sum":"fcceab54c3ca0755203293193fcb8907","Name":"U44_3.72_01_09_2026.fwpkg","Release":"2026-01-13T08:13:11","Revision":"","SHA1Sum":"f4951694ba46268060ddc70537619ccf8d1b6823","SHA256Sum":"f314d4026402f3fa0d4993f3c7040374d44d9bb6cabeaea509229851896b5024","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.72_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant ML30 Gen10(U44)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 (U44) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T09:33:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.103と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.70_08-08-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_01-09-2026"}],"SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"9a604862d25e41de88e4d1afea320efe"}]},{"ProductId":"b5747db463a34c8c8ef853b408ae6b5c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2022で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1079096","DateModified":"2025-11-16T23:27:15","FileList":["cp069520.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"cda1f0e7ae68fdb9abdf827a883251dc","Name":"cp069520.exe","Release":"2025-11-16T23:12:49","Revision":"B","SHA1Sum":"4d93dd4fe118fa8df2dd309c6a6b575e92d6a797","SHA256Sum":"3bfec1080203d7bb7c5f266e65e32ae60589b541f179289698dfe6ed1ac35724","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.0.13.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel E1R Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Intel E1Rドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Intel E1R Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T06:35:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>機能変更: E1Rドライバーからの仮想化の削除。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"cn"}],"Version":"14.0.13.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>機能変更: E1Rドライバーからの仮想化の削除。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"cn"}],"Version":"14.0.13.0"}],"SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1c61d8d675f54d34beb3a14863e597f6"}]},{"ProductId":"0a8a267d13ac4d5588a19d1f0bcc2f5d","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"16_35_8002-MCX512F-ACH_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30116","Version":"16.35.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor HPE Ethernet 10/25Gb 2ポートSFP28 MCX512F-ACHTアダプター"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter(P13188-B21)</td><td>16.35.8002</td><td>MT_0000000416</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter(P13188-B21)</td><td>16.35.8002</td><td>MT_0000000416</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter(P13188-B21)</td><td>16.35.8002</td><td>MT_0000000416</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"5339617","DateModified":"2025-10-09T08:20:12","FileList":["16_35_8002-MCX512F-ACH_Ax_Bx.pldm.signed","16_35_8002-MCX512F-ACH_Ax_Bx.pldm.xml","payload.json"],"MD5Sum":"effd9021428aa8657a571b6b1764c9f6","Name":"16_35_8002-MCX512F-ACH_Ax_Bx.pldm.fwpkg","Release":"2025-10-09T08:18:01","Revision":"","SHA1Sum":"19e1f1491802bd7c613f73c0986bd44adcde2629","SHA256Sum":"190bb5bb4b9fa1661e01fa80a684376ae5b3aa31a268c6524cf505a0606a1c37","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715b30116"],"TypeOfChange":"1","Version":"16.35.8002"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動し -> 左側の[ファームウェア&OSソフトウェア]をクリック、 -> [ファームウェアのアップデート]をクリック、 -> [Choose File]をクリックして、サポートされているPLDMファイルを参照し、 -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package(FWPKG) for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ(FWPKG) for HPE Ethernet 10/25Gb 2ポートSFP28 MCX512F-ACHT アダプター"},{"Lang":"cn","Value":"NVIDIA Firmware Package(FWPKG) for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-30T11:48:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン16.35.4506で修正されました。</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"16.35.4506"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"16.35.8002"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX512F-ACHT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"d94a720ec9f6438fb5481e8c958847a1"}]},{"ProductId":"45e734b674094fd09fe52836988b3440","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System"},{"Lang":"ja","Value":"ドライバ - システム"},{"Lang":"cn","Value":"驱动程序 - 系统"}],"Description":[{"Lang":"en","Value":"This component provides drivers for HPE NVDIMM-N devices and HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory) installed on systems running Microsoft Windows Server 2016."},{"Lang":"ja","Value":"このコンポーネントは、Microsoft Windows Server 2016を実行しているシステムにインストールされているHPE NVDIMM-NデバイスおよびHPE Persistent Memoryデバイス(Intel Optane DC Persistent Memoryを搭載)のドライバーを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1000704","DateModified":"2025-11-18T05:46:21","FileList":["cp069727.xml","cpqsetup.exe","hpenvmbus.cat","HpeNvmBus.inf","HpeNvmBus.pdb","HpeNVMBus.sys","HpeNvmBusApi.h","HpeNVMdisk0101.cat","HpeNvmDisk0101.inf","HpeNvmDisk0101.pdb","Hpenvmdisk0101.sys","HpeNvmDsm.h","HpeNvmInstaller.dll","install.xml"],"MD5Sum":"1641a939a54e49e3c660ce6c6f26e2ba","Name":"cp069727.exe","Release":"2025-11-18T05:44:20","Revision":"F","SHA1Sum":"2b34996da6f4c9c4ebcb1364d42c86a169e5578c","SHA256Sum":"6236bed09da0fb08a4508adab4798b74e635d1d0b84a262fee3237573070af9e","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece0b66b06"],"TypeOfChange":"0","Version":"3.0.2.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Steps to install this Smart Component:</p><ul><li>If a previous version is already installed, it is recommended to first stop all use of the Persistent Memory devices and disks, and uninstall&nbsp;it from the Control Panel, Uninstall a Program.</li><li>Download the Smart Component to a directory on your hard drive and change to that directory.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the Install button to proceed with the installation.</li></ul>"},{"Lang":"ja","Value":"<p>このSmartコンポーネントをインストールする手順：</p><ul><li>以前のバージョンがすでにインストールされている場合は、最初にPersistent Memoryデバイスとディスクの使用をすべて停止し、[コントロールパネル]の[プログラムのアンインストール]からアンインストールすることをお勧めします。</li><li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li><li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li><li>[インストール]ボタンをクリックして、インストールを開始してください。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Non-Volatile Memory Drivers for Microsoft Windows Server 2016"},{"Lang":"ja","Value":"HPE不揮発性メモリドライバーfor Microsoft Windows Server 2016"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4096"},"SupportedDevices":[{"Id":"ACPI\\VEN_ACPI&DEV_0012","TargetGUID":"","Type":"pnp"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-18T05:41:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SBOM要件をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"3.0.2.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"3.0.2.0"}],"SWKeys":[{"Name":"HpeNvmInstaller.dll","SWKeyExpectedPath":"%systemdrive%\\cpqsystem\\pnpdrvs"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ce1f27b87467497c9a70f6bfd3ebf4b3"}]},{"ProductId":"fb9faa50a5034cfe8c3861f763b25770","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp068010.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2927800","DateModified":"2025-11-18T05:59:22","FileList":["cp068010.compsig","cp068010.zip","cp069641.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"7eec9acd6bba299fe2144415fe68ce1e","Name":"cp069641.exe","Release":"2025-11-18T05:58:05","Revision":"B","SHA1Sum":"1fe44a14a3d665614571667e87ce937ae937d166","SHA256Sum":"23d0bfd3c8d70f40c90bc5afe902d8400f26433b62d6d2b1d2dee11cb2e890c4","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &nbsp;&lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &nbsp;&lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant ML30 Gen10 Plus"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T06:46:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance. This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance. This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance. This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance. This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3415b62c2b414ab18dcdf0162cb564f1"}]},{"ProductId":"635ad6621b8d4c52b8b9de3325345e84","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021109.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.09"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021109.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.09"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021109.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.09"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021109.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.09"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters. "},{"Lang":"ja","Value":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターをアップグレートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3843656","DateModified":"2025-12-04T08:05:16","FileList":["QLAFWUpdate.exe","adapters.properties","bk020501.bin","cp068327.xml","cpqsetup.exe","hbaapi2_x64.dll","installer.dll","mh021109.bin","payload.json","ql2xhai2.dll","qlafwupdate.properties","qlafwupdate.txt","qlcoutil.dll","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"MD5Sum":"682f331e411f059d1e73d2854ccaddb9","Name":"cp068327.exe","Release":"2025-12-04T07:50:15","Revision":"","SHA1Sum":"f0a7fc97ad54b1faeb07a373171eb62b6fddbefb","SHA256Sum":"cb3903f7edd1bf170143f67bdddf36ca0e7c3a433b1594b5cc09003871925e15","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2025.11.01"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":250,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />［インストール］ボタンをクリックして、インストールを開始します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"},{"Lang":"ja","Value":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T07:08:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"<p>Fixed the following:</p><ol><li>Windows BitLocker causes the system boot due to ROM signature failure during POST.</li><li>Increase an internal timeout value for SPI/Flash read.</li></ol>","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">アダプター</p></td><td><p dir=\"LTR\">速度</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">ファームウェア</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">ブートBIOS</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBデュアルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBシングルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"<p>以下を修正しました。</p><ol><li>Windows BitLockerにより、POST中にROM署名エラーが発生し、システムが起動します。</li><li>SPI/フラッシュ読み取りの内部タイムアウト値を増やします。</li></ol>","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"<p>Fixed the following:</p><ol><li>Windows BitLocker causes the system boot due to ROM signature failure during POST.</li><li>Increase an internal timeout value for SPI/Flash read.</li></ol>","Lang":"cn"}],"Version":"2025.05.02"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.11.01"}],"SWKeys":[{"Name":"qlogic","SWKeyExpectedPath":"firmware:qlogic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"65d2976282394c82900b937b5ee93fc0"}]},{"ProductId":"5e76fbf672b8432aa6436d748dacb463","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWJRQおよびMB006000JWJRP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB008000JWJRQ_MB006000JWJRP&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB008000JWJRQ_MB006000JWJRP&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18129037","DateModified":"2025-03-07T10:44:47","FileList":["/CP065930_BUILD_7.data","/CP065930.vmexe64","/CP065930.vmfile","/CP065930_VMw.zip","/CP065930.xml","/payload.json","/CP065930_VMw.zip/index.xml","/CP065930_VMw.zip/vendor-index.xml","/CP065930_VMw.zip/metadata.zip","/CP065930_VMw.zip/vib20/CP065930/HPE_bootbank_CP065930_HPD9.7-8.0.0.20613240.vib","/CP065930_VMw.zip/metadata.zip/vendor-index.xml","/CP065930_VMw.zip/metadata.zip/vmware.xml","/CP065930_VMw.zip/metadata.zip/vibs/CP065930--1350340004423881024.xml","/CP065930_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065930_HPD9.7-8.0.0.20613240.xml"],"MD5Sum":"ce0e829ab90e239455f8c0a330096412","Name":"CP065930.zip","Release":"2025-03-07T10:43:50","Revision":"G","SHA1Sum":"3e2018e725bbc2be281e65d99657c3e8bd2c7392","SHA256Sum":"44d1209e8831d63a8ef9ee7b5d5267ee61c694a2de7804b56e0629e1bf3ae4a5","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP065930","Version":"HPD9.7-8.0.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWJRQ and MB006000JWJRP  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWJRQおよび MB006000JWJRP ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000JWJRQ","TargetGUID":"4d2340a5-3042-3830-3030-304a574a5251","Type":"sas"},{"Id":"MB006000JWJRP","TargetGUID":"4d2340a5-3042-3630-3030-304a574a5250","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T09:33:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e55788193b7641ea9c26ad4ae15c77bc"}]},{"ProductId":"213beba0c6a2454792ef817e13082a5c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4742784","DateModified":"2025-08-02T21:02:58","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-1.1/CP067365.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-1.1/HVLAnAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067365.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067365.scexe"],"MD5Sum":"06309e0e0dc4ff16333ff5db8cc7de7e","Name":"firmware-hdd-ca21e169e2_0HPG1-1.1_amd64.deb","Release":"2025-08-03T01:54:17","Revision":"","SHA1Sum":"6d5073ab5d48bf417c27f7b8f6fb47bc24b944b3","SHA256Sum":"963f8bb516de66cff441b9116602ed9354333bd405695048be80b6cc28fb5425","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP041494.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000GWKGV Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000GWKGV Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000GWKGV","TargetGUID":"4d2340a5-3042-3430-3030-3047574b4756","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T13:03:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8fad6cd2a12c4daabf33267834c93ef4"}]},{"ProductId":"c101b138be5d4ee79271a6725d6813d4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK8</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp; &nbsp; &nbsp; &nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK8</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp; &nbsp; &nbsp; &nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"20414743","DateModified":"2025-03-18T11:38:14","FileList":["/CP066266_BUILD_1.data","/CP066266.vmexe64","/CP066266.vmfile","/CP066266_VMw.zip","/CP066266.xml","/payload.json","/CP066266_VMw.zip/index.xml","/CP066266_VMw.zip/vendor-index.xml","/CP066266_VMw.zip/metadata.zip","/CP066266_VMw.zip/vib20/CP066266/HPE_bootbank_CP066266_GPK8.1-8.0.0.20613240.vib","/CP066266_VMw.zip/metadata.zip/vendor-index.xml","/CP066266_VMw.zip/metadata.zip/vmware.xml","/CP066266_VMw.zip/metadata.zip/vibs/CP066266-6569565759163152348.xml","/CP066266_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066266_GPK8.1-8.0.0.20613240.xml"],"MD5Sum":"88e9f029fad825992ceade36e6e8aef5","Name":"CP066266.zip","Release":"2025-03-18T11:37:27","Revision":"B","SHA1Sum":"3ef3c348432bcf1ce6ce29c79d466c0548d8f4b9","SHA256Sum":"aaf7aac7c6334d40672b9618c97a4e9c911ff38f3ffce181f169d8ec8cbbbc1d","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8","VibList":[{"Name":"CP066266","Version":"GPK8.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6XRUL960G","TargetGUID":"002340a5-434b-364d-5852-554c39363047","Type":"nvme"},{"Id":"KCM6XRUL7T68","TargetGUID":"002340a5-434b-364d-5852-554c37543638","Type":"nvme"},{"Id":"KCM6XRUL1T92","TargetGUID":"002340a5-434b-364d-5852-554c31543932","Type":"nvme"},{"Id":"KCM6XVUL3T20","TargetGUID":"002340a5-434b-364d-5856-554c33543230","Type":"nvme"},{"Id":"KCM6XRUL3T84","TargetGUID":"002340a5-434b-364d-5852-554c33543834","Type":"nvme"},{"Id":"KCM6XVUL800G","TargetGUID":"002340a5-434b-364d-5856-554c38303047","Type":"nvme"},{"Id":"KCM6XVUL6T40","TargetGUID":"002340a5-434b-364d-5856-554c36543430","Type":"nvme"},{"Id":"KCM6XVUL1T60","TargetGUID":"002340a5-434b-364d-5856-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-18T09:31:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"GPK7"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK8"}],"SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8a9d3371bcc34b00baf2141b4ce8a1d0"}]},{"ProductId":"4f319faf890642fc80a3d8719760c121","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.00"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.00"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.00"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.00"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.00"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.00"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のストレージコントローラー用のファームウェアを提供します。 HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10 コントローラー"},{"Lang":"cn","Value":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>同じファームウェアバージョンの () 内のそのパッケージバージョンには、同じファームウェアバイナリイメージが含まれます。ユーザーは、同じファームウェアバージョンを再フラッシュする必要はありません。</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"25527888","DateModified":"2025-12-05T06:49:09","FileList":["/CP069172_BUILD_9.data","/CP069172.vmexe64","/CP069172.vmfile","/CP069172_VMw.zip","/CP069172.xml","/payload.json","/CP069172_VMw.zip/index.xml","/CP069172_VMw.zip/vendor-index.xml","/CP069172_VMw.zip/metadata.zip","/CP069172_VMw.zip/vib20/CP069172/HPE_bootbank_CP069172_8.00.9-8.0.0.20613240.vib","/CP069172_VMw.zip/metadata.zip/vendor-index.xml","/CP069172_VMw.zip/metadata.zip/vmware.xml","/CP069172_VMw.zip/metadata.zip/vibs/CP069172--8819137170838670099.xml","/CP069172_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069172_8.00.9-8.0.0.20613240.xml"],"MD5Sum":"374713e615571fc30b1feace14069139","Name":"CP069172.zip","Release":"2026-02-02T00:00:00","Revision":"","SHA1Sum":"de5219a5619a272d1441c31da06f29092c6a54a7","SHA256Sum":"1a1511123c3dbffeeaae1e3e0c4f942e0e92071832be5d772c32506875172610","Size":"24MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.00","VibList":[{"Name":"CP069172","Version":"8.00.9-8.0.0.20613240"}]}],"Installation":{"Command":"CP069172.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=c03190790\">Service Pack for ProLiant Quick Start Guide</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0 / 9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p> </p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン (</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報 (rootまたは管理者ユーザー名およびパスワード) を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=c03190790\">Service Pack for ProLiantクイックスタートガイド</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>ESXiホスト上のTech Support Modeを有効にします。</li><li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。) </li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>次のコマンドを使用してCPXXXXXX.vmexeが実行可能であることを確実にしてください：</li></ul><p>             chmod +x CPXXXXXX.vmexe    </p><ul><li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe</li><li>Smartコンポーネントの指示に従います。</li><li>ログアウトします。</li><li>ESXiホスト上のTech Support Modeを無効にします。</li></ul><p><strong>VIBファイルを実行するための追加情報。</strong></p><p><u>ESXi 8.0 / 9.0でVIBファイルを実行するために必要なコマンド</u></p><ul><li>vibファイルのインストール：esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip。</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li><li>vibファイルの削除：esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul><p><フルパス>は、zipファイル (CPxxxxxx.zip) が解凍された一時ディレクトリパスです</p>"},{"Lang":"cn","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=c03190790\">Service Pack for ProLiant Quick Start Guide</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0 / 9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 Controllers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10コントローラー"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2026-03-03T08:05:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"cn"}],"Version":"8.00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"cn"}],"Version":"8.00"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a03f9ce066e24c478d4982121ae9620c"}]},{"ProductId":"ec5fd859b967489ab6f67ad677712984","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000600JWCPFおよびEH000900JWCPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EH000600JWCPF and EH000900JWCPH Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EH000600JWCPF and EH000900JWCPH Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19829256","DateModified":"2025-03-06T08:30:14","FileList":["/CP066003_BUILD_7.data","/CP066003.vmexe64","/CP066003.vmfile","/CP066003_VMw.zip","/CP066003.xml","/payload.json","/CP066003_VMw.zip/index.xml","/CP066003_VMw.zip/vendor-index.xml","/CP066003_VMw.zip/metadata.zip","/CP066003_VMw.zip/vib20/CP066003/HPE_bootbank_CP066003_HPDD.7-1OEM.800.1.0.20613240.vib","/CP066003_VMw.zip/metadata.zip/vendor-index.xml","/CP066003_VMw.zip/metadata.zip/vmware.xml","/CP066003_VMw.zip/metadata.zip/vibs/CP066003--5506596142151457280.xml","/CP066003_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066003_HPDD.7-1OEM.800.1.0.20613240.xml"],"MD5Sum":"f1e9e3165fae580b0ae33072cb747060","Name":"CP066003.zip","Release":"2025-03-06T08:29:22","Revision":"B","SHA1Sum":"5320c777fabba6b3f85d1e6187ef6fd17a19453d","SHA256Sum":"ab74742487e0244f1d3a09058e6df3f4caaf256e6944ac83985d4de043950f6f","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD","VibList":[{"Name":"CP066003","Version":"HPDD.7-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040536.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp;./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp;./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - EH000600JWCPF and EH000900JWCPH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EH000600JWCPF","TargetGUID":"452340a5-3048-3030-3630-304a57435046","Type":"sas"},{"Id":"EH000900JWCPH","TargetGUID":"452340a5-3048-3030-3930-304a57435048","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:01:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"cn"}],"Version":"HPDD"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDD"}],"SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f33261fbafa04ae9884d1df548b7524d"}]},{"ProductId":"00459d4dc4844a0c9aaf3dd87b1a7fe8","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H08","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H08_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000221","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on HPE ProLiant e910/e910t Server Blade running a supported Operating System in an HPE Edgeline EL8000 Converged Edge System."},{"Lang":"ja","Value":"このコンポーネントは、HPE Edgeline EL8000 コンバージドエッジシステムでサポートされているオペレーティングシステムを実行しているHPE ProLiant e910/e910tサーバーブレードに直接インストールできるアップデートされたシステムファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on HPE ProLiant e910/e910t Server Blade running a supported Operating System in an HPE Edgeline EL8000 Converged Edge System."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11538848","DateModified":"2026-01-14T02:56:56","FileList":["cp070226.xml","cpqsetup.exe","H08_3.62_01_09_2026.signed.flash","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"1fb13a3eae2fe22658817e624e5be874","Name":"cp070226.exe","Release":"2026-01-14T02:54:35","Revision":"","SHA1Sum":"7ef1e0812a9ae6561d5409cf936f59fba8a4707c","SHA256Sum":"bd31496dbeb039bda0a25b4e2b5024006cdb10841e125b5d0891ed2a437b02a2","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant e910/e910t Server Blade (H08)"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant e910/e910tサーバーブレード (H08)"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant e910/e910t Server Blade (H08)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64-bit)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:32:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"H08","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"b4c3cb38bebd455b8edc86e43d598cab"}]},{"ProductId":"fdb3892daac8474c8262b342acf8f35f","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"235.1.164014"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"235.1.164014"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"235.1.164014"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"235.1.164014"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"235.1.164014"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet firmware running under VMware vSphere 8.0 and VMware vSphere 9.0"},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 8.0およびVMware vSphere 9.0で動作するHPE ProLiant Broadcom NetXtreme-E Ethernetファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet firmware running under VMware vSphere 8.0 and VMware vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16558351","DateModified":"2025-12-18T03:30:00","FileList":["/CP070091_BUILD_1.data","/CP070091.vmexe64","/CP070091.vmfile","/CP070091_VMw.zip","/CP070091.xml","/payload.json","/CP070091_VMw.zip/index.xml","/CP070091_VMw.zip/vendor-index.xml","/CP070091_VMw.zip/metadata.zip","/CP070091_VMw.zip/vib20/CP070091/HPE_bootbank_CP070091_5.27.5.1-8.0.0.20613240.vib","/CP070091_VMw.zip/metadata.zip/vendor-index.xml","/CP070091_VMw.zip/metadata.zip/vmware.xml","/CP070091_VMw.zip/metadata.zip/vibs/CP070091-1585950971355617336.xml","/CP070091_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070091_5.27.5.1-8.0.0.20613240.xml"],"MD5Sum":"87a46ee958fb8c30832a117e8347d150","Name":"CP070091.zip","Release":"2025-12-18T03:29:21","Revision":"","SHA1Sum":"97cc70ea2c0f33a226f321d2e2f1ba57f9a98e7d","SHA256Sum":"6a5cc452ad591990e7f18561977232ca72e2d2fcbbc268b9bd369e09c7218d41","Size":"15MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"5.27.5","VibList":[{"Name":"CP070091","Version":"5.27.5.1-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンライン ファームウェアアップグレードユーティリティ for VMware"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2026-01-17T07:53:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品拡張機能により、特定の監視機能が無効になっている場合に過熱を防ぐためのセルフシャットダウン機能が有効になります。 <br />これは、もともとファームウェアバージョン223.1.135.7以降を搭載して出荷された新しいハードウェアにのみ適用され、それ以前のリビジョンでは有効になりません。</p>","Fixes":"<ul><li>この製品は、BCM5741xアダプターのアップグレード後にファームウェアバージョン詳細のアップデートに失敗し、カードが動作していないと表示されていた問題を修正します。 </li><li>この製品は、10GBASE-LR SFP+の検出に失敗し、誤ったデフォルトとリンク障害が発生していた問題を修正します。</li><li>この製品は、iLO BMCがOCP NIC上のIPを共有している場合、OSの再起動中にリンクフラップが発生していた問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"5.27.0"},{"ReleaseNotes":[{"Enhancements":"<p>BCM235_GCA2</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>BCM235_GCA2</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>BCM235_GCA2</p>","Fixes":"","Lang":"cn"}],"Version":"5.27.5"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d936ccd4cd9d4c80921fc3e295950cee"}]},{"ProductId":"17b00802f88a41f591cee6102caaf9d2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4503000","DateModified":"2025-11-17T03:31:12","FileList":["cp068655.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SSKYBT512EDB.rel"],"MD5Sum":"a05e6379c7e87a9892945af135c9954e","Name":"cp068655.exe","Release":"2025-11-17T03:25:54","Revision":"C","SHA1Sum":"414eaee2cf6ad92f24df9e62e00e9049c2bdb5ff","SHA256Sum":"3402f61eb05bdfdc21606c18a2d82388f956d0aec7913d45fc35a9da2c9fbf13","Size":"4MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EG001800JWJNR","TargetGUID":"452340a5-3047-3130-3830-304a574a4e52","Type":"sas"},{"Id":"EG002400JWJNT","TargetGUID":"452340a5-3047-3230-3430-304a574a4e54","Type":"sas"},{"Id":"EG002400MXJQT","TargetGUID":"452340a5-3047-3230-3430-304d584a5154","Type":"sas"},{"Id":"EG001800JXLWB","TargetGUID":"452340a5-3047-3130-3830-304a584c5742","Type":"sas"},{"Id":"EG002400JXLWC","TargetGUID":"452340a5-3047-3230-3430-304a584c5743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:44:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fb460e6ce42541ccaa5dad6a16ccd663"}]},{"ProductId":"79949863b3a5452487d1035ae487743e","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUANG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3231-3030-304759455350","Version":"HPG1"},{"DeviceName":"Seagate-Summit-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUANG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3631-3030-304759455646","Version":"HPG1"},{"DeviceName":"Seagate-Summit-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUANG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3032-3030-304759455648","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models:  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"},{"Lang":"ja","Value":"This package provides firmware for the following drive models:  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"},{"Lang":"cn","Value":"This package provides firmware for the following drive models:  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Fix FW assert and other regular fixes.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Fix FW assert and other regular fixes.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Fix FW assert and other regular fixes.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3297036","DateModified":"2024-10-25T08:32:18","FileList":["payload.json","Seagate_Summit_SUMMITSUANG1.HPb","Seagate_Summit_SUMMITSUANG1.xml"],"MD5Sum":"a9ebeac65c8f1b3aacfbf52e6ddbc7a4","Name":"Seagate_Summit_SUMMITSUANG1.fwpkg","Release":"2024-10-25T08:30:02","Revision":"","SHA1Sum":"decedcb617ea27d08f042e549677cc478522cdbd","SHA256Sum":"2fc609cf4364c8564ad816c12a040bcc63f864c236a1f8ae590ea1570468bb2c","Size":"3MB","TargetGUIDs":["002340a5-424d-3231-3030-304759455350","002340a5-424d-3631-3030-304759455646","002340a5-424d-3032-3030-304759455648"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB12000GYESP","TargetGUID":"002340a5-424d-3231-3030-304759455350","Type":"sata"},{"Id":"MB16000GYEVF","TargetGUID":"002340a5-424d-3631-3030-304759455646","Type":"sata"},{"Id":"MB20000GYEVH","TargetGUID":"002340a5-424d-3032-3030-304759455648","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-25T06:14:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix FW assert and other regular fixes</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix FW assert and other regular fixes</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix FW assert and other regular fixes</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB12000GYESP","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB16000GYEVF","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB20000GYEVH","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"ea555e67d9a742e8bdd8e6455315b8b1"}]},{"ProductId":"f87c073a909044b99d96fdb0f46f7c69","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4432860","DateModified":"2025-08-02T20:10:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-1.1/CP067356.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-1.1/SHPEEVANSTG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067356.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067356.scexe"],"MD5Sum":"85df27084f79f7d1f0680f79b0fa5f45","Name":"firmware-hdd-7a1edae8e7_0HPG1-1.1_amd64.deb","Release":"2025-08-03T01:00:04","Revision":"","SHA1Sum":"f05ac08ec07b9cbd66af327e8531c2f1617b45da","SHA256Sum":"cf7120b4fecc8404cdb4da138b67d16fe9459255f619bb97efe82cf23b3d4305","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000GWZGT","TargetGUID":"4d2340a5-3042-3031-3030-3047575a4754","Type":"sata"},{"Id":"MB012000GWZGU","TargetGUID":"4d2340a5-3042-3231-3030-3047575a4755","Type":"sata"},{"Id":"MB014000GWZGV","TargetGUID":"4d2340a5-3042-3431-3030-3047575a4756","Type":"sata"},{"Id":"MB016000GWZHD","TargetGUID":"4d2340a5-3042-3631-3030-3047575a4844","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:51:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5e2b7945a07543b4aca406ee45938842"}]},{"ProductId":"ae807ea8d44943a3b60bbbbd54cd062d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 9.0."},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 9.0."},{"Lang":"ja","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.13.2.0</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;1.13.2.0</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.13.2.0</p>"}],"Files":[{"Bytes":"123326","DateModified":"2025-09-22T04:01:16","FileList":["/cp067481.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vib20/igbn/INT_bootbank_igbn_1.13.2.0-1OEM.900.0.24580437.vib","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vmware.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vibs/igbn-831206253632276349.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/bulletins/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.xml"],"MD5Sum":"6c6116a3707af9d1e7416b3f2d57b60a","Name":"cp067481.zip","Release":"2025-09-22T04:01:06","Revision":"","SHA1Sum":"3467ad2cd622f77d9a778c5a76a60b0b1422b6cb","SHA256Sum":"b69576b8f846b5fea2f9a27744160fb86ff7ad5063cb64aaf4c2bf7ee4d42f63","Size":"120KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"igbn","Version":"1.13.2.0-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel igbn Driver for VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE Intel igbn Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE Intel igbn Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-06T03:15:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"Intel-igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"eb551c6b6b314fbfa83789debb75d74d"}]},{"ProductId":"18633ffffaeb4435bcda138419e66c7a","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.62 (01/09/2026)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11926304","DateModified":"2026-01-14T08:29:00","FileList":["cp070249.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U34_3.62_01_09_2026.signed.flash"],"MD5Sum":"beabb013e7e1aac5ac212cbc7a5db644","Name":"cp070249.exe","Release":"2026-01-14T08:26:33","Revision":"","SHA1Sum":"b94be7a140fa0d60517ed57e33840becbec4c417","SHA256Sum":"2a43ee7736e9810055df8078c722c2a3a2d4abb84091f486286c1169d7f84668","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;</p><p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> </p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;</p><p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34)サーバー "},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:40:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"f1b14712b7c142dbbbb8d5192e5b870b"}]},{"ProductId":"d9d151c798d94a31a9d263cef309ab70","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Agentless Management Service (AMSD) provides support for HPE Integrated Lights-Out Embedded Health and Alerting."},{"Lang":"ja","Value":"Agentless Management Service（AMSD）は、HPE Integrated Lights Out内蔵ヘルスおよびアラートのサポートを提供します。"},{"Lang":"cn","Value":"Agentless Management Service (AMSD) provides support for HPE Integrated Lights-Out Embedded Health and Alerting."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"6055502","DateModified":"2026-01-23T14:16:07","FileList":["./etc/default/ahslog","./etc/default/amsd","./etc/default/amsd_rev","./etc/default/cpqIde","./etc/default/cpqScsi","./etc/default/cpqiScsi","./etc/default/mr_cpqScsi","./etc/default/smad","./etc/default/smad_rev","./lib/udev/rules.d/81-cpqFca.rules","./lib/udev/rules.d/81-cpqiScsi.rules","./sbin/ahslog","./sbin/amscli","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqIde","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./sbin/smad","./sbin/smad_rev","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/share/amsd/amsd.license","./usr/share/doc/amsd/README.Debian","./usr/share/doc/amsd/changelog.Debian.gz","./usr/share/doc/amsd/copyright","./usr/share/man/man1/ahslog.1m.gz","./usr/share/man/man1/smad.1m.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/smartupdate/amsd/component.xml"],"MD5Sum":"10d6f7a46ef536b301d9a2949173328f","Name":"amsd_4.5.0-2107.3-ubuntu24_amd64.deb","Release":"2026-01-23T14:12:04","Revision":"","SHA1Sum":"91ac0fc5301c5c16c260c819960dbb2fce156bc8","SHA256Sum":"1586f1ce1dbbf1eba25817408576721266e2baba0c121d9c16dd762e1a8a38c4","Size":"5MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.5.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation method:</strong><br />&nbsp;<br />Using dpkg command<br />To install the package, type:</p><ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul></li><li>To check whether the package is loaded properly type:<ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul><li>man amsd</li></ul></li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation method:</strong><br />&nbsp;<br />Using dpkg command<br />To install the package, type:</p><ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul></li><li>To check whether the package is loaded properly type:<ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul><li>man amsd</li></ul></li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation method:</strong><br />&nbsp;<br />Using dpkg command<br />To install the package, type:</p><ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul><li>dpkg -i amsd-&lt;version&gt;.deb</li></ul></li><li>To check whether the package is loaded properly type:<ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul><li>man amsd</li></ul></li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service for Ubuntu 24.04 LTS"},{"Lang":"ja","Value":"Agentless Management Service for Ubuntu 24.04 LTS"},{"Lang":"cn","Value":"Agentless Management Service for Ubuntu 24.04 LTS"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-08T08:58:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Instead of using sed command, using awk command to fetch the right column name</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>sedコマンドを使用する代わりに、awkコマンドを使用して正しい列名を取得します</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Instead of using sed command, using awk command to fetch the right column name</p>","Lang":"cn"}],"Version":"4.4.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Instead of using sed command, using awk command to fetch the right column name</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>sedコマンドを使用する代わりに、awkコマンドを使用して正しい列名を取得します</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Instead of using sed command, using awk command to fetch the right column name</p>","Lang":"cn"}],"Version":"4.5.0"}],"SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:deb"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7a29cd8572214a6fb508a00566f2fec9"}]},{"ProductId":"7dbb2b9a498c4df1a461e7b3079cc8f5","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"235.1.164014"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"235.1.164014"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"235.1.164014"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"235.1.164014"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"235.1.164014"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"235.1.164014"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"235.1.164014"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"235.1.164014"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains NVM Image version 235.1.164014&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains NVM Image version 235.1.164014&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains NVM Image version 235.1.164014&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">235.1.164.2<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"}],"Files":[{"Bytes":"8067950","DateModified":"2025-12-17T21:05:03","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/CP070090.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/CP070090.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.25.5-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070090.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070090.scexe"],"MD5Sum":"53ac94054d374a9b91354e2f644df19d","Name":"firmware-nic-bcm-nxe-1.25.5-1.1.x86_64.rpm","Release":"2025-12-18T02:55:37","Revision":"","SHA1Sum":"8e3c07fb06e9f4ffe97ff8370b35222bc574bf99","SHA256Sum":"c799ec81db18b5512f17517cbbc4e3e7fe18e23bd7d91eb66148e869bb19e118","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"1.25.5"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command: <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em></li></ul><p style=\"margin-left:80px\">This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p style=\"margin-left:80px\">This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><em><strong>インストールされたrpmによるアダプターファームウェアのアップデート。</strong></em></p><ul><li>コマンド<em>rpm -ivh <rpm_filename>.rpmを使用して、このNICファームウェアrpmをインストールします。  </em></li></ul><p style=\"margin-left:80px\">このコマンドは、\"/usr/lib/x86_64-linux-gnu\"へコンテンツを抽出します。<br />CPXXXXXX.scexeスクリプトは、\"scexe-compat''フォルダーにあります。詳細については、\"firmware-nic-*\"フォルダーのCPXXXXXX.txtファイルを参照してください。\"firmware-nic-*\"フォルダーの実際の名前は、インストールされるrpmのバージョンに基づきます。  </p><ul><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します。<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>（\"/usr/lib/x86_64-linux-gnu/scexe-compat\"内）。</li><li>firmware-nic-*ロケーションの<em>./setup</em>   </li></ul></li><br /><li>このrpmをアンインストールするには、次のコマンドを実行します：<em>rpm -e <rpm_package_name></em></li></ul><p><em><strong>rpmのインストールなしでのアダプターファームウェアのアップデート。</strong></em></p><ul><li>rpmの内容を次のコマンドを入力して抽出します：<em>rpm2cpio <rpm_filename>.rpm | cpio -id</em></li></ul><p style=\"margin-left:80px\">これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</p><ul><li>usr/lib/x86_64-linux-gnu/firmware-nic-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-nic-フォルダーの実際の名前は、rpmのバージョンに基づきます。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアアップグレードの結果は、\"/var/cpq/\"にあるCPXXXXXX.logに保存されます。</li><li>NPAR（NICパーティショニング）モードを有効化すると、デバイスIDが変更されます。これに従い、NPARを有効化すると、DID 0x16D7および0x16D8を使用するアダプターが、0x16ECおよび0x16EEにそれぞれ変更されますが、NPARを有効化し、RoCEも有効化すると、0x16EDおよび0x16EFに変更されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアrpmパッケージのインストール (rpm -ivh)は、アダプターのファームウェアをアップデートしません。rpmのインストールは、単にローカルシステムへrpmの内容を解凍するだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li><li>ファームウェアをアップグレードする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップグレードしていきます。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command: <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em></li></ul><p style=\"margin-left:80px\">This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p style=\"margin-left:80px\">This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2026-01-17T07:53:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品拡張機能により、特定の監視機能が無効になっている場合に過熱を防ぐためのセルフシャットダウン機能が有効になります。 <br />これは、もともとファームウェアバージョン223.1.135.7以降を搭載して出荷された新しいハードウェアにのみ適用され、それ以前のリビジョンでは有効になりません。</p>","Fixes":"<ul><li>この製品は、BCM5741xアダプターのアップグレード後にファームウェアバージョン詳細のアップデートに失敗し、カードが動作していないと表示されていた問題を修正します。 </li><li>この製品は、10GBASE-LR SFP+の検出に失敗し、誤ったデフォルトとリンク障害が発生していた問題を修正します。</li><li>この製品は、iLO BMCがOCP NIC上のIPを共有している場合、OSの再起動中にリンクフラップが発生していた問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"1.25.0"},{"ReleaseNotes":[{"Enhancements":"<p>BCM235_GCA2</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>BCM235_GCA2</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>BCM235_GCA2</p>","Fixes":"","Lang":"cn"}],"Version":"1.25.5"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"39afcf44527449b4a8fb66060255b6b2"}]},{"ProductId":"58058fc7c39a49caa2844dbe139ab3f9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20592416","DateModified":"2025-07-09T13:51:10","FileList":["/CP067762_BUILD_1.data","/CP067762.vmexe64","/CP067762.vmfile","/CP067762_VMw.zip","/CP067762.xml","/payload.json","/CP067762_VMw.zip/index.xml","/CP067762_VMw.zip/vendor-index.xml","/CP067762_VMw.zip/metadata.zip","/CP067762_VMw.zip/vib20/CP067762/HPE_bootbank_CP067762_HPDB.1-8.0.0.20613240.vib","/CP067762_VMw.zip/metadata.zip/vendor-index.xml","/CP067762_VMw.zip/metadata.zip/vmware.xml","/CP067762_VMw.zip/metadata.zip/vibs/CP067762-3375346338345393197.xml","/CP067762_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067762_HPDB.1-8.0.0.20613240.xml"],"MD5Sum":"06395acef98e29d819daa59e1a1fbe96","Name":"CP067762.zip","Release":"2025-07-09T13:50:23","Revision":"B","SHA1Sum":"9b8e90e3a8550e490e93eed41d0185f7da2ee45e","SHA256Sum":"24d90a9af5bfc2402ed80d200dd779b198dbc01e56dcf94bcf87d9b1dfcb1c03","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP067762","Version":"HPDB.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP042785.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EG001800JWJNR","TargetGUID":"452340a5-3047-3130-3830-304a574a4e52","Type":"sas"},{"Id":"EG002400JWJNT","TargetGUID":"452340a5-3047-3230-3430-304a574a4e54","Type":"sas"},{"Id":"EG002400MXJQT","TargetGUID":"452340a5-3047-3230-3430-304d584a5154","Type":"sas"},{"Id":"EG001800JXLWB","TargetGUID":"452340a5-3047-3130-3830-304a584c5742","Type":"sas"},{"Id":"EG002400JXLWC","TargetGUID":"452340a5-3047-3230-3430-304a584c5743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-06T07:37:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ファームウェアバージョンHPDBを修正し、供給の継続性のために最新のNAND世代との互換性を追加します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the Firmware version HPDB adds compatibility with the latest NAND generation for continuity of supply.</li></ul>","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8f951512a1dc47adac31d8c51080aa2b"}]},{"ProductId":"094c75ee866a4b1bb6f0e035ac316695","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities."},{"Lang":"ja","Value":"iLO 5 Channel Interfaceドライバーは、iLO 5管理コントローラーとの通信を行うことを可能にするソフトウェアです。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"579328","DateModified":"2025-11-18T03:13:13","FileList":["cp069722.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"MD5Sum":"4f5eb052572d35bcc317fce07ab5800c","Name":"cp069722.exe","Release":"2025-11-18T03:10:55","Revision":"I","SHA1Sum":"7721cc32a14c1b549e319c103e1b429d066fe5ae","SHA256Sum":"97a1759cfc9ae1322f870c31450e8e32333feedd2d53947745f12c2ead3f4241","Size":"565KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.1.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"iLO 5チャネルインターフェイスドライバーfor Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T03:07:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"}],"SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"60c84d67122f4120814e871a3b5341df"}]},{"ProductId":"d1422347af3f4f888596c242a7fdb7a6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"},{"Lang":"en","Value":"Software - Storage Fibre Channel HBA"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"Lang":"cn","Value":"软件 - 存储光纤通道 HBA"}],"Description":[{"Lang":"en","Value":"This package contains utilities and libraries to enable HPE Storage Fibre Channel connectivity on Linux Server for QLogic Host Bus Adapter"},{"Lang":"cn","Value":"This package contains utilities and libraries to enable HPE Storage Fibre Channel connectivity on Linux Server for QLogic Host Bus Adapter"},{"Lang":"ja","Value":"このパッケージには、Linuxサーバー上でQLogicホストバスアダプターに対してHPE Storageファイバーチャネル接続を有効にするためのユーティリティとライブラリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"866864","DateModified":"2025-10-28T15:20:22","FileList":["./opt/QLogic_Corporation/qlogic-libs","./opt/QLogic_Corporation/qlogic-libs/README.LIBQLSDM","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-aarch64.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64le.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-x86_64.so","./opt/QLogic_Corporation/qlogic-libs/ql-hba-collect-1.12.tgz","./usr/share/smartupdate/HPE-CNA-FC-hpeqlgc-Enablement-Kit/component.xml"],"MD5Sum":"8878cff127d08591792dcacb71ca975b","Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.rpm","Release":"2025-10-28T15:18:28","Revision":"e","SHA1Sum":"e461016954ad2eb9545afbaa7c8add4da6303776","SHA256Sum":"5c7c8916c5e01acc8d310197b0246382b6ed8699755247d01f2fbf79b65c6f9a","Size":"846KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1"],"TypeOfChange":"1","Version":"6.0.0.1-4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The Enablement Kit requires that the target environment have the libHBAAPI package installed from your OS installation media.</p><p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p><p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p><p>Rewrite of same Enablement kit version on&nbsp;SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --replacepkgs --nodeps</p><p>&nbsp;Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack 4&nbsp;and SuSE Linux Enterprise Server 15 service pack 5&nbsp;has to be performed using --reinstall option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p><p>For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>The Enablement Kit requires that the target environment have the libHBAAPI package installed from your OS installation media.</p><p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p><p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p><p>Rewrite of same Enablement kit version on&nbsp;SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --replacepkgs --nodeps</p><p>&nbsp;Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack 4&nbsp;and SuSE Linux Enterprise Server 15 service pack 5&nbsp;has to be performed using --reinstall option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p><p>For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>イネーブルメントキットは、OSインストールメディアからlibHBAAPIパッケージをインストールしたターゲット環境を必要とします。</p><p>このバージョンのイネーブルメントキットは、以前のバージョンが行ったようなRAMディスクの再構築またはドライバーパラメーターの設定といった追加の機能を提供しません。  これらの機能を実行する方法については、Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guideの「Additional setup」セクションを参照してください。  リファレンスガイドは、次のリンクから入手可能です：</p><p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p><p>SUSE Linux Enterprise Server 12サービスパック5での同じイネーブルメントキットバージョンの書き換えは、–forceまたは--replacepkgsと--nodepsオプションを使用して実行する必要があります。</p><p>例：rpm –Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-<version>.noarch.rpm --force --nodeps</p><p>                rpm –Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-<version>.noarch.rpm --replacepkgs --nodeps</p><p> SUSE Linux Enterprise Server 15サービスパック4およびSUSE Linux Enterprise Server 15サービスパック5での同じイネーブルメントキットバージョンの書き換えは、--reinstallオプションを使用して実行する必要があります。</p><p>例：rpm –Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-<version>.noarch.rpm --force --nodeps</p><p>詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Fibre Channel Enablement Kit for Host Bus Adapter for Linux"},{"Lang":"cn","Value":"HPE QLogic Fibre Channel Enablement Kit for Host Bus Adapter for Linux"},{"Lang":"ja","Value":"HPE QLogicファイバーチャネルイネーブルメントキットforホストバスアダプターfor Linux"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-22T10:38:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated the kit to version 6.0.0.1-4</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン6.0.0.1-4にキットをアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated the kit to version 6.0.0.1-4</p>","Fixes":"","Lang":"cn"}],"Version":"6.0.0.1-4"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the kit to version 6.0.0.1-4</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン6.0.0.1-4にキットをアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated the kit to version 6.0.0.1-4</p>","Fixes":"","Lang":"cn"}],"Version":"6.0.0.1-4"}],"SWKeys":[{"Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"10f65b3327384eed803da4c0f160f230"}]},{"ProductId":"e3abad55c63d42f3bfc00d8212a8e9d4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"5129722","DateModified":"2025-09-17T13:07:08","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/CP068859.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/TA14SXe0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068859.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068859.scexe"],"MD5Sum":"3d584c84343ad93ebe7240d4ab77146b","Name":"firmware-hdd-c7df7ceedb-HPD9-2.1.x86_64.rpm","Release":"2025-09-17T17:56:05","Revision":"B","SHA1Sum":"57ae2f4e61510c35a5bc5449cd3e6d6145ddaf21","SHA256Sum":"4fcce98b217a4fe670dace26c0a10e111d9d617ff802995cb54bd1a529075ec8","Size":"4MB","TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP041670.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP.<nnnnnn>scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000600JWHPH","TargetGUID":"452340a5-3048-3030-3630-304a57485048","Type":"sas"},{"Id":"EH000900JWHPK","TargetGUID":"452340a5-3048-3030-3930-304a5748504b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:58:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1d6229f8dc1e47bdbf9d5dbc3f39809b"}]},{"ProductId":"51c52bf006bd4c60b09797563ff886bf","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. SSASCRIPTING - Scripting can be performed in offline or online environments.  The SSA Scripting application has 2 scripting modes – Capture and Input."},{"Lang":"cn","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. SSASCRIPTING - Scripting can be performed in offline or online environments.  The SSA Scripting application has 2 scripting modes – Capture and Input."},{"Lang":"ja","Value":"Smart Storage Administrator CLI（SSACLI）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるコマンドラインベースのディスク構成プログラムです。SSASCRIPTING - スクリプトは、オフラインまたはオンライン環境で実行することができます。SSAスクリプティングアプリケーションは、2つのスクリプティングモード - CaptureおよびInputを持っています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"13232125","DateModified":"2025-12-05T02:20:58","FileList":["./opt/smartstorageadmin/ssacli","./opt/smartstorageadmin/ssacli/bin","./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-6.60-8.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/man/man8/ssacli.8.gz","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/smartupdate/ssacli/component.xml"],"MD5Sum":"38d89e97d3e8611fe6d651e08d820b45","Name":"ssacli-6.60-8.0.x86_64.rpm","Release":"2025-12-05T02:18:05","Revision":"","SHA1Sum":"ddcb2126473ce6e81b40c4e41631773b9b582fc3","SHA256Sum":"f0e5d18946adf2ececd2676205f8d3134bbe3b7a2bec731f9e751e893442a76c","Size":"12MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"TypeOfChange":"1","Version":"6.60.8.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>SSACLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSACLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssacli and the executable name is ssacli which is located in /usr/sbin.</li></ul>"},{"Lang":"ja","Value":"<ul><li>SSACLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSACLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssacli and the executable name is ssacli which is located in /usr/sbin.</li></ul>"},{"Lang":"cn","Value":"<ul><li>SSACLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSACLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssacli and the executable name is ssacli which is located in /usr/sbin.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) CLI for Linux 64ビット for Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:26:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"cn"}],"Version":"6.50.11.0"},{"ReleaseNotes":[{"Enhancements":"<p>RC drop 6.60.8.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RC drop 6.60.8.0.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>RC drop 6.60.8.0.</p>","Fixes":"","Lang":"cn"}],"Version":"6.60.8.0"}],"SWKeys":[{"Name":"ssacli","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5ee7637cddbb4b778e4943aa0b18c662"}]},{"ProductId":"74e8451e230741319455926a99f9eebc","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 10で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 10."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"230666","DateModified":"2025-09-16T08:35:43","FileList":["./etc/depmod.d/kmod-igb.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/igb/igb.ko","./usr/share/doc/kmod-igb","./usr/share/doc/kmod-igb/COPYING","./usr/share/doc/kmod-igb/README","./usr/share/doc/kmod-igb/pci.updates","./usr/share/man/man7/igb.7.gz","./usr/share/smartupdate/kmod-igb/component.xml"],"MD5Sum":"354c7b1c21f5856ad00325581ed20566","Name":"kmod-igb-5.19.4-1.rhel10u0.x86_64.rpm","Release":"2025-09-16T08:31:01","Revision":"","SHA1Sum":"c4d38a98c21b1b4e13aa83c739c401144eb0ee05","SHA256Sum":"76186dfb9040c2b6c32da9c5dc495106772e72098ac99930c450bf53f572555e","Size":"225KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca93656a5"],"TypeOfChange":"1","Version":"5.19.4-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel igb Drivers for Red Hat Enterprise Linux 10"},{"Lang":"ja","Value":"HPE Intel igbドライバー for Red Hat Enterprise Linux 10"},{"Lang":"cn","Value":"HPE Intel igb Drivers for Red Hat Enterprise Linux 10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T04:30:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Red Hat Enterprise Server 10をサポートするための初回リリースです。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release to support Red Hat Enterprise Linux 10.</p>","Fixes":"","Lang":"cn"}],"Version":"5.19.3-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"5.19.4-1"}],"SWKeys":[{"Name":"kmod-igb","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ff746205df92495a9ed3b31776163ba8"}]},{"ProductId":"3ab4de78da484144892d6ddcd8fd9b97","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished&nbsp;<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe-kmp-default) to (igb-ixgbe-default). Now we revert this change from (ixgbe-kmp-default) to (<strong>hp</strong>-ixgbe-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-ixgbe-kmp-default and ixgbe-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbe-kmp-default and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>  このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません <br />    - RPMパッケージ名は（<strong>hp</strong>-ixgbe-kmp-default）から（igb-ixgbe-default）に変更されました。この変更を（ixgbe-kmp-default）から（<strong>hp</strong>-ixgbe-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-ixgbe-kmp-defaultとixgbe-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e ixgbe-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished&nbsp;<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe-kmp-default) to (igb-ixgbe-default). Now we revert this change from (ixgbe-kmp-default) to (<strong>hp</strong>-ixgbe-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-ixgbe-kmp-default and ixgbe-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbe-kmp-default and then install the updated RPM.</p>"}],"Files":[{"Bytes":"383761","DateModified":"2025-09-15T15:44:22","FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"MD5Sum":"5d2396173e395be81b07c14651abd1ac","Name":"hp-ixgbe-kmp-default-6.2.5_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-09-15T15:37:05","Revision":"","SHA1Sum":"af728338a1422210acdea37f805d7bb8aa54204f","SHA256Sum":"7a11f16e9a0b649b354808a4142d7d0ae176de2da9b5d8b4a6f47fbddda131fa","Size":"374KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"TypeOfChange":"1","Version":"6.2.5-1"},{"Bytes":"383602","DateModified":"2025-09-15T15:49:28","FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbe","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"MD5Sum":"4cb47742c3591a3d5abd9d7dc807f92f","Name":"hp-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-09-15T15:37:05","Revision":"","SHA1Sum":"4c5636a46c8332b8de45b0abba64e9e176c1d6d1","SHA256Sum":"85a60fe33d0fc27e80016bbae7cbaac1353e754695b236af7959017e39488b67","Size":"374KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"TypeOfChange":"1","Version":"6.2.5-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"57ad","SubDev":"00FF","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad808600ff","Type":"pci","Ven":"8086"},{"Dev":"57B1","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57b180860003","Type":"pci","Ven":"8086"},{"Dev":"57AD","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-57ad80860003","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-12T09:31:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product now adds support for E610 device.</li><li>This product adds support for NVM update during FW recovery.</li></ul>","Fixes":"<ul><li>This product fixes remove 128 CPUs limit for XDP.</li><li>This product fixes stop setting carrier on while the adapter is down.</li><li>This product fixes use netdev-&gt;fcoe_mtu when required.</li><li>Known issue: Firmware OROM version displays as &quot;0.0.0&quot; via &quot;ethtool -i&quot;.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品では、E610デバイスのサポートが追加されました。</li><li>この製品は、FWリカバリ中のNVMアップデートのサポートを追加します。</li></ul>","Fixes":"<ul><li>この製品は、XDPの128CPU制限を修正します。</li><li>この製品は、アダプターがダウンしている間、キャリアをオンにするのを停止するように修正します。</li><li>この製品は、必要に応じて netdev->fcoe_mtu を使用するように修正します。</li><li>既知の問題: 「ethtool -i」を実行すると、ファームウェア OROM バージョンが「0.0.0」と表示されます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product now adds support for E610 device.</li><li>This product adds support for NVM update during FW recovery.</li></ul>","Fixes":"<ul><li>This product fixes remove 128 CPUs limit for XDP.</li><li>This product fixes stop setting carrier on while the adapter is down.</li><li>This product fixes use netdev-&gt;fcoe_mtu when required.</li><li>Known issue: Firmware OROM version displays as &quot;0.0.0&quot; via &quot;ethtool -i&quot;.</li></ul>","Lang":"cn"}],"Version":"6.1.5-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"6.2.5-1"}],"SWKeys":[{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"231b867aabf04de799c7361dde7b9812"}]},{"ProductId":"eb308b8c4ae741aa983a2b26d428e1e8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4467296","DateModified":"2025-08-03T01:34:15","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-1.1/CP067336.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-1.1/KAPM6ALSHPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067336.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067336.scexe"],"MD5Sum":"7eb84c72f37f26264170de171d86a655","Name":"firmware-hdd-42aff4675b_0HPD5-1.1_amd64.deb","Release":"2025-08-03T06:28:14","Revision":"","SHA1Sum":"fd0c7ada4cebb282ae569bbe97fa1561ce086851","SHA256Sum":"e09d9d95c24437cdb1905a33214c8cb4c449b025cb617eb3352d88f95dee0385","Size":"4MB","TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP041670.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EO000800PXDCK","TargetGUID":"452340a5-304f-3030-3830-30505844434b","Type":"sas"},{"Id":"MO000800PXDBP","TargetGUID":"4d2340a5-304f-3030-3830-305058444250","Type":"sas"},{"Id":"EO000400PXDBQ","TargetGUID":"452340a5-304f-3030-3430-305058444251","Type":"sas"},{"Id":"EO001600PXDCH","TargetGUID":"452340a5-304f-3130-3630-305058444348","Type":"sas"},{"Id":"MO001600PXDCC","TargetGUID":"4d2340a5-304f-3130-3630-305058444343","Type":"sas"},{"Id":"MO006400PXDCE","TargetGUID":"4d2340a5-304f-3630-3430-305058444345","Type":"sas"},{"Id":"VO007680PXDBU","TargetGUID":"562340a5-304f-3730-3638-305058444255","Type":"sas"},{"Id":"VO001920PXDBR","TargetGUID":"562340a5-304f-3130-3932-305058444252","Type":"sas"},{"Id":"MO003200PXDCD","TargetGUID":"4d2340a5-304f-3330-3230-305058444344","Type":"sas"},{"Id":"VO015300PXDBV","TargetGUID":"562340a5-304f-3531-3330-305058444256","Type":"sas"},{"Id":"VO000960PXDBN","TargetGUID":"562340a5-304f-3030-3936-30505844424e","Type":"sas"},{"Id":"VO003840PXDBT","TargetGUID":"562340a5-304f-3330-3834-305058444254","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:08:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e0d77138af284d2bbe04785348c14802"}]},{"ProductId":"6d5cd83fc05f4da0a652797154f87a4c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60およびKCM6FVUL3T20"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"20938011","DateModified":"2025-03-18T09:13:07","FileList":["/CP066263_BUILD_1.data","/CP066263.vmexe64","/CP066263.vmfile","/CP066263_VMw.zip","/CP066263.xml","/payload.json","/CP066263_VMw.zip/index.xml","/CP066263_VMw.zip/vendor-index.xml","/CP066263_VMw.zip/metadata.zip","/CP066263_VMw.zip/vib20/CP066263/HPE_bootbank_CP066263_GPK6.1-8.0.0.20613240.vib","/CP066263_VMw.zip/metadata.zip/vendor-index.xml","/CP066263_VMw.zip/metadata.zip/vmware.xml","/CP066263_VMw.zip/metadata.zip/vibs/CP066263-3683837525927449643.xml","/CP066263_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066263_GPK6.1-8.0.0.20613240.xml"],"MD5Sum":"b8d7073f0e4e2c32fe13a64b48f417e9","Name":"CP066263.zip","Release":"2025-03-18T09:12:23","Revision":"B","SHA1Sum":"de3624c105c9f478851a14db9ce80cd99423c86b","SHA256Sum":"88544191be544619022adb6a5b38c6997b125922e59afd10f14f556dd32d4a27","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6","VibList":[{"Name":"CP066263","Version":"GPK6.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives"},{"Lang":"ja","Value":"オンラインNVMeSSDフラッシュコンポーネントfor VMware ESXi - KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60、およびKCM6FVUL3T20ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6FRUL1T92","TargetGUID":"002340a5-434b-364d-4652-554c31543932","Type":"nvme"},{"Id":"KCM6FRUL3T84","TargetGUID":"002340a5-434b-364d-4652-554c33543834","Type":"nvme"},{"Id":"KCM6FVUL3T20","TargetGUID":"002340a5-434b-364d-4656-554c33543230","Type":"nvme"},{"Id":"KCM6FVUL1T60","TargetGUID":"002340a5-434b-364d-4656-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-18T07:07:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"GPK5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK6"}],"SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ac62c5f3848048bab2198cffa62bafad"}]},{"ProductId":"707f07cb4d404d119f2788d168e17586","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v4.00 (01/09/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v4.00 (01/09/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34244208","DateModified":"2026-01-13T02:37:07","FileList":["A43_4.00_01_09_2026.signed.flash","cp070341.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"5005b44d4605f73ca5d56503d7066f20","Name":"cp070341.exe","Release":"2026-01-13T02:34:44","Revision":"","SHA1Sum":"24d7cfed7642894d61350e837df7aa20717dd7a3","SHA256Sum":"9eaf5b7f10bba253b231a5103826629da09c0701570e6b048c67d2641ec3f777","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus（A43）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:34:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>改善点/新しい機能:</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。</p><p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.92_11-27-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"247883a235ae4eba83e5dd3e0a27f663"}]},{"ProductId":"db808d6aa2e24648bcc5e3f46d635b1a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Lights-Out Management"},{"Lang":"ja","Value":"ソフトウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"软件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"HPE Lights-Out Online Configuration utility is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the Linux operating system without requiring a reboot of the server."},{"Lang":"ja","Value":"HPE Lights-Outオンライン設定ユーティリティは、サーバーを再起動しないでLinux オペレーティングシステムから、ProLiant Integrated Lights-Out（iLO）プロセッサーを設定するために使用するコマンドラインユーティリティです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"63634","DateModified":"2025-06-19T09:52:18","FileList":["./sbin/hponcfg","./usr/lib64/libhponcfg64.so","./usr/share/doc/hponcfg","./usr/share/doc/hponcfg/readme.txt","./usr/share/smartupdate/hponcfg/component.xml"],"MD5Sum":"5421536da7b6a75438388cf81f029a20","Name":"hponcfg-6.1.0-0.x86_64.rpm","Release":"2025-06-19T09:50:27","Revision":"A","SHA1Sum":"98ecadf350d759cd5399e08b28c0e86d1af94aef","SHA256Sum":"dfd43f64998af8b459c3db06e9712a93814756f7bc6fae1268d6de594f8ecc36","Size":"62KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8"],"TypeOfChange":"0","Version":"6.1.0.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><p>If a previous version of the Hponcfg utility has been installed, it must be removed before this package can be installed. To remove the previous version of the package, type the following :</p><ul><li>rpm -e hponcfg</li></ul><p>To install the package with dependency check, type:</p><ul><li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li></ul><p>To install the package withour dependency check, type:</p><ul><li>rpm -ivh --nodeps hponcfg-x.x.x.x86_64.rpm</li></ul><p>After installation, the executable for hponcfg utility can be found under the directory /sbin.</p>"},{"Lang":"ja","Value":"<p>システム管理者（root）としてログインし、RPMをハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p><p>Hponcfgユーティリティの以前のバージョンをインストールしている場合は、削除しておかないと、このパッケージをインストールできません。パッケージの以前のバージョンを削除するには、次のように入力します：</p><ul><li>rpm -e hponcfg</li></ul><p>依存関係のチェックを行ってパッケージをインストールするには、次のように入力します。</p><ul><li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li></ul><p>依存関係のチェックを行わずにパッケージをインストールするには、次のように入力します。</p><ul><li>rpm -ivh --nodeps hponcfg-x.x.x.x86_64.rpm</li></ul><p>インストール後は、/sbinディレクトリにhponcfgの実行可能ファイルが見つかります。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T)"},{"Lang":"ja","Value":"HPE Lights-Outオンライン設定ユーティリティfor Linux (AMD64/EM64T)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Id":"5219994","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3306103c3381","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3307103c3381","Type":"pci","Ven":"103C"},{"Dev":"3308","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3308103c3381","Type":"pci","Ven":"103C"},{"Dev":"3300","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3300103c3381","Type":"pci","Ven":"103C"},{"Dev":"3301","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3301103c3381","Type":"pci","Ven":"103C"},{"Dev":"3302","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3302103c3381","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103c"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"SUSE LINUX Enterprise Server 10 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-09T05:23:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>None</p>","Fixes":"<p>Fixed an issue where&nbsp;hponcfg was&nbsp;failing on Linux operating system with OpenSSL 3.X</p>","Lang":"en"},{"Enhancements":"<p>なし</p>","Fixes":"<p>OpenSSL 3.Xを搭載したLinuxオペレーティングシステムでhponcfgが失敗する問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"<p>None</p>","Fixes":"<p>Fixed an issue where&nbsp;hponcfg was&nbsp;failing on Linux operating system with OpenSSL 3.X</p>","Lang":"cn"}],"Version":"6.1.0-0"},{"ReleaseNotes":[{"Enhancements":"<p>to be added</p>","Fixes":"<p>to be added</p>","Lang":"en"},{"Enhancements":"<p>to be added</p>","Fixes":"<p>to be added</p>","Lang":"ja"},{"Enhancements":"<p>to be added</p>","Fixes":"<p>to be added</p>","Lang":"cn"}],"Version":"6.1.0.0"}],"SWKeys":[{"Name":"hponcfg","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I38","Model":"HPE ProLiant BL660c Gen9 Server"},{"Family":"I32","Model":"HP ProLiant BL660c Gen8 Server"},{"Family":"A26","Model":"HP ProLiant BL465c Gen8 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant BL460c Gen9 Server"},{"Family":"I31","Model":"HP ProLiant BL460c Gen8 Server"},{"Family":"I30","Model":"HP ProLiant BL420c Gen8 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P79","Model":"HP ProLiant DL580 Gen8 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P77","Model":"HP ProLiant DL560 Gen8 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A28","Model":"HP ProLiant DL385p Gen8 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P70","Model":"HP ProLiant DL380p Gen8 Server"},{"Family":"P73","Model":"HP ProLiant DL380e Gen8 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"P71","Model":"HP ProLiant DL360p Gen8 Server"},{"Family":"P73","Model":"HP ProLiant DL360e Gen8 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"P80","Model":"HP ProLiant DL320e Gen8 v2 Server"},{"Family":"J05","Model":"HP ProLiant DL320e Gen8 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"J03","Model":"HP ProLiant DL160 Gen8 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P72","Model":"HP ProLiant ML350p Gen8 Server"},{"Family":"J02","Model":"HP ProLiant ML350e Gen8 Server"},{"Family":"P78","Model":"HP ProLiant ML310e Gen8 v2 Server"},{"Family":"J04","Model":"HP ProLiant ML310e Gen8 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"P88","Model":"HP ProLiant ML10 Server"},{"Family":"P74","Model":"HP ProLiant SL4540 Gen8 3 Node Server"},{"Family":"P75","Model":"HP ProLiant SL270s Gen8 Server"},{"Family":"P75","Model":"HP ProLiant SL270s Gen8 SE Server"},{"Family":"P75","Model":"HP ProLiant SL250s Gen8 Server"},{"Family":"P75","Model":"HP ProLiant SL230s Gen8 Server"},{"Family":"P83","Model":"HP ProLiant SL210t Gen8 Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"P94","Model":"HP ProLiant XL220a Gen8 v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL215n Gen10 Plus"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"J06","Model":"HP ProLiant MicroServer Gen8"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"I36","Model":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"Family":"I31","Model":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"R11","Model":"HPE ProLiant RL300 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"R13","Model":"HPE ProLiant Compute DL384 Gen12"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6abdf231475c435c92bb558b96dfc97b"}]},{"ProductId":"a08198f75ae64d5f81f313aee3e10a81","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_OCP3_9p55_CFGID7p2_K97342_8000FDFD.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3863.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_9p55_CFGID7p2_K97470_8000FE06.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3863.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3863.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3863.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3863.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3863.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 8.0 and vSphere 9.0."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 8.0 and vSphere 9.0."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 8.0 and vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"6742403","DateModified":"2025-09-16T09:33:44","FileList":["/CP068729_BUILD_1.data","/CP068729_VMw.zip","/CP068729.xml","/payload.json","/CP068729_VMw.zip/index.xml","/CP068729_VMw.zip/vendor-index.xml","/CP068729_VMw.zip/metadata.zip","/CP068729_VMw.zip/vib20/CP068729/HPE_bootbank_CP068729_3.28.0.1-8.0.0.20613240.vib","/CP068729_VMw.zip/metadata.zip/vendor-index.xml","/CP068729_VMw.zip/metadata.zip/vmware.xml","/CP068729_VMw.zip/metadata.zip/vibs/CP068729-682382829497315241.xml","/CP068729_VMw.zip/metadata.zip/bulletins/Smart-Component-CP068729_3.28.0.1-8.0.0.20613240.xml"],"MD5Sum":"1a57b29e5d97f7678d9f81ee42f95fb8","Name":"CP068729.zip","Release":"2025-09-16T09:33:12","Revision":"","SHA1Sum":"5534130e484f1ea4dbaca75eee46e24ba416973c","SHA256Sum":"ab2c54b10698c96b348e9847af17581059d7ffad27d9b19489719f6055a546d5","Size":"6MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"3.28.0","VibList":[{"Name":"CP068729","Version":"3.28.0.1-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":3600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca93656a5","SWKey":"kmod-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec805649d9","SWKey":"kmod-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","SWKey":"i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Intel-i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Online Firmware Upgrade Utility for VMware "},{"Lang":"ja","Value":"Intelオンラインファームウェアアップグレードユーティリティfor VMware "},{"Lang":"cn","Value":"Intel Online Firmware Upgrade Utility for VMware "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T03:04:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product removes RDE AutoSpeedNegotiationEnabled property.</li><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product removes RDE AutoSpeedNegotiationEnabled property.</li><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product removes RDE AutoSpeedNegotiationEnabled property.</li><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"cn"}],"Version":"3.27.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"3.28.0"}],"SWKeys":[{"Name":"IS_INTEL","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e507085ad84f46a49d4efa5d0809c1da"}]},{"ProductId":"a6a815c1e19641d7b77e2e862e63ca3a","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"16_35_8002-MCX562A-ACA_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30052","Version":"16.35.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor Mellanox MCX562A-ACAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><p>&nbsp;</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</td><td>16.35.8002</td><td>MT_0000000241</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><p>&nbsp;</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</td><td>16.35.8002</td><td>MT_0000000241</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><p>&nbsp;</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>NVIDIA Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</td><td>16.35.8002</td><td>MT_0000000241</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"5644628","DateModified":"2025-10-09T08:21:19","FileList":["16_35_8002-MCX562A-ACA_Ax_Bx.pldm.signed","16_35_8002-MCX562A-ACA_Ax_Bx.pldm.xml","payload.json"],"MD5Sum":"5348f704e39b2db8855ea39bf427dd44","Name":"16_35_8002-MCX562A-ACA_Ax_Bx.pldm.fwpkg","Release":"2025-10-09T08:18:54","Revision":"","SHA1Sum":"850fa48becab25977498e0ce83ef12bd13d5c81d","SHA256Sum":"6dd59428bb2fb0b82642ee6969f70cd67824bfc3658285614bffb497b4743788","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715b30052"],"TypeOfChange":"1","Version":"16.35.8002"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動し -> 左側の[ファームウェア&OSソフトウェア]をクリック、 -> [ファームウェアのアップデート]をクリック、 -> [Choose File]をクリックして、サポートされているPLDMファイルを参照し、 -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ（FWPKG）for Mellanox MCX562A-ACAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-30T11:57:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン16.35.4506で修正されました。</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"16.35.4506"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version&nbsp;16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"16.35.8002"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX562A-ACAI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL215n Gen10 Plus"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"3ff097f4cf984edc81f6a4c3ee15a91b"}]},{"ProductId":"a1b0fb5619dd4bf685499171488aaaa2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB018000GXMTK and MB020000GXMTQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB018000GXMTKおよびMB020000GXMTQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB018000GXMTK and MB020000GXMTQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB018000GXMTK and MB020000GXMTQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19691219","DateModified":"2025-03-06T13:33:30","FileList":["/CP065977_BUILD_2.data","/CP065977.vmexe64","/CP065977.vmfile","/CP065977_VMw.zip","/CP065977.xml","/payload.json","/CP065977_VMw.zip/index.xml","/CP065977_VMw.zip/vendor-index.xml","/CP065977_VMw.zip/metadata.zip","/CP065977_VMw.zip/vib20/CP065977/HPE_bootbank_CP065977_HPG3.2-1OEM.800.1.0.20613240.vib","/CP065977_VMw.zip/metadata.zip/vendor-index.xml","/CP065977_VMw.zip/metadata.zip/vmware.xml","/CP065977_VMw.zip/metadata.zip/vibs/CP065977-6999833380529871258.xml","/CP065977_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065977_HPG3.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"afdbf3fc20ce278ec1ff0f8ac34ea275","Name":"CP065977.zip","Release":"2025-03-06T13:32:35","Revision":"B","SHA1Sum":"cdcf72eea55f2627568cc99a63720dc0270d954f","SHA256Sum":"05295bb54a84bfb45039c64b6baed0c182d1236e433f15e1526af8990efef079","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP065977","Version":"HPG3.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042785.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000GXMTK and MB020000GXMTQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB018000GXMTKおよびMB020000GXMTQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB020000GXMTQ","TargetGUID":"4d2340a5-3042-3032-3030-3047584d5451","Type":"sata"},{"Id":"MB018000GXMTK","TargetGUID":"4d2340a5-3042-3831-3030-3047584d544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:11:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Assertの修正、現在のファームウェアの改善、およびバグ修正を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3997df854d184cccb8bf94004912f89b"}]},{"ProductId":"f643d6c27d8f4b5d8eb0ee9c718b2a48","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improves data integrity.&nbsp;</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide a minor performance improvement.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improves data integrity.&nbsp;</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide a minor performance improvement.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4601872","DateModified":"2025-08-02T22:58:15","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-1.1/CP067395.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-1.1/TAMG09acHPG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067395.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067395.scexe"],"MD5Sum":"c9e3ca45e73ea47235a3fee6eaa3b7e1","Name":"firmware-hdd-e0171a2936_0HPG4-1.1_amd64.deb","Release":"2025-08-03T03:51:05","Revision":"","SHA1Sum":"2116d6e13a281655eefe7ce6001ac900bc223d8c","SHA256Sum":"66e44e664e9d7ad20f37073679a50fe8cd1d3d9b5d3f22801e23542df1f50bc7","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"CP042460.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB012000GZYVT","TargetGUID":"4d2340a5-3042-3231-3030-30475a595654","Type":"sata"},{"Id":"MB014000GZYVU","TargetGUID":"4d2340a5-3042-3431-3030-30475a595655","Type":"sata"},{"Id":"MB016000GZYVV","TargetGUID":"4d2340a5-3042-3631-3030-30475a595656","Type":"sata"},{"Id":"MB018000GYCLL","TargetGUID":"4d2340a5-3042-3831-3030-304759434c4c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:41:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improves data integrity.&nbsp;</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide a minor performance improvement.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Improves data integrity.&nbsp;</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide a minor performance improvement.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improves data integrity.&nbsp;</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide a minor performance improvement.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"83ec1fa034ee4b5eae1799f1161a15bd"}]},{"ProductId":"67fb0d734fd248cca1eff5e7b321a8b6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Video"},{"Lang":"ja","Value":"ドライバ - ビデオ"},{"Lang":"cn","Value":"驱动程序 - 视频"}],"Description":[{"Lang":"en","Value":"This component provides advanced video support for the Matrox G200eH3 video controller."},{"Lang":"ja","Value":"このコンポーネントは、Matrox G200eH3ビデオコントローラー対応の高度なビデオ機能を提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1638264","DateModified":"2025-11-18T08:18:20","FileList":["cp069739.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","mxg200eh.cat","MxG200eH.inf","MxG2hDO64.sys"],"MD5Sum":"002af114aaad9bed1fea93c2c188a576","Name":"cp069739.exe","Release":"2025-11-18T08:16:38","Revision":"E","SHA1Sum":"c0d8e70cc76941d60df8314bdd9f164b6527c259","SHA256Sum":"044990fed406c368ad87b742fa1f26ef4647b1909c97c366922f6f3815d1e95b","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"TypeOfChange":"0","Version":"9.15.1.268"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P><P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P><P>Click the \"Install\" button to perform the driver installation.</P>"},{"Lang":"ja","Value":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P><P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P><P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Matrox G200eH3 Video Controller Driver for Microsoft Windows 64-bit"},{"Lang":"ja","Value":"Matrox G200eH3ビデオコントローラードライバーfor Microsoft Windows 64ビット"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"10000"},"SupportedDevices":[{"Dev":"0538","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-102b-0538159000e4","Type":"pci","Ven":"102B"},{"Dev":"0538","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-102b-05381590027f","Type":"pci","Ven":"102B"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T08:10:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"9.15.1.268"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"9.15.1.268"}],"SWKeys":[{"Name":"MxG2hDO64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3c4ee434232a45659b386e450c35ec11"}]},{"ProductId":"1f91b74faf084255b33a9e102dcf221d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U45_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11592832","DateModified":"2026-01-14T00:43:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.62_2026_01_09-1.1/CP070360.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.62_2026_01_09-1.1/U45_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070360.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070360.scexe"],"MD5Sum":"112896ce7da54f246e0795f19d4f6710","Name":"firmware-system-u45-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-14T06:34:35","Revision":"","SHA1Sum":"72a451df980ef7f74a8b53dd2043010720aecf4d","SHA256Sum":"a5ce20b5e23cf36ac949c56f9bc7441046036a45d47ef8f099b92689c6bb8b90","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>RPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:55:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fed2903678e54d9ca4b2da6639198be8"}]},{"ProductId":"95e1a7b8a2664cd8b8d67128eff9bb87","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーは、オペレーティングシステムがロックアップした場合にサーバーをリセットするASRハードウェアタイマーを管理します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"598456","DateModified":"2025-11-18T02:44:20","FileList":["cp069705.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"MD5Sum":"bb39ac28ba2bf37d0c30023d66c78746","Name":"cp069705.exe","Release":"2025-11-18T02:42:50","Revision":"F","SHA1Sum":"1005ac996573008cff17bbb9b2ddc0a6ba9f9a46","SHA256Sum":"e514c6e13a460dfde2f18acbfd9215d982c1604b67a3b769d4760f473f310361","Size":"584KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.1.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2016 and 2019"},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーfor Microsoft Windows Server 2016および2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-17T09:05:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SBOM要件をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"}],"SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"77d7d74fe2a4417e91c40096649dc637"}]},{"ProductId":"eaadba373a2b4b7ab82c00e6e1f55628","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB014000GWUDA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000GWUDA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG2</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;&nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG2</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;&nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20905222","DateModified":"2025-03-07T06:42:53","FileList":["/CP065991_BUILD_4.data","/CP065991.vmexe64","/CP065991.vmfile","/CP065991_VMw.zip","/CP065991.xml","/payload.json","/CP065991_VMw.zip/index.xml","/CP065991_VMw.zip/vendor-index.xml","/CP065991_VMw.zip/metadata.zip","/CP065991_VMw.zip/vib20/CP065991/HPE_bootbank_CP065991_HPG3.4-1OEM.800.1.0.20613240.vib","/CP065991_VMw.zip/metadata.zip/vendor-index.xml","/CP065991_VMw.zip/metadata.zip/vmware.xml","/CP065991_VMw.zip/metadata.zip/vibs/CP065991-2927407355464872258.xml","/CP065991_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065991_HPG3.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"523e6b9a3a246bc5c4b51702bf8fbd38","Name":"CP065991.zip","Release":"2025-03-07T06:42:07","Revision":"C","SHA1Sum":"957c0d9c30f9b7f0e94ccba7109c288094185176","SHA256Sum":"99a76c613c78638bd133d5056e9a4c7a6b32cd2e2f0743d3429e6bef5d1c8abc","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP065991","Version":"HPG3.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041507.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000GWUDAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000GWUDA","TargetGUID":"4d2340a5-3042-3431-3030-304757554441","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:09:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ba3b6d5b24a24394ab8fb7f685fa7394"}]},{"ProductId":"8c4f7b25cd054f74b804a271ef25619f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"Lang":"ja","Value":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10およびGen11コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされるバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と機能強化を入手するため、インストールする必要があります。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"116506","DateModified":"2025-12-05T02:37:19","FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/smartpqi","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/70","./usr/lib/.build-id/70/c952e7dbf82b6c964165b1ad2590c3f1ae7147","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"MD5Sum":"6377e4e731838cfe373d423b71542229","Name":"kmod-smartpqi-2.1.38-022.rhel10u0.x86_64.rpm","Release":"2025-12-05T02:32:31","Revision":"","SHA1Sum":"e206fa91b47a9e211eb7844924532b4f90d5f570","SHA256Sum":"c7c87a0fce6746cc436d13204d718b28b9c8937778fe3213f855cc990e24fc62","Size":"113KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.38-022"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp; <strong>-</strong>-oldpackage --replacefiles --replacepkgs<strong>&nbsp;</strong>kmod-smartpqi-&lt;version&gt;.rhel9&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li></ul><p>&nbsp;</p><p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e kmod-smartpqi-&lt;version&gt;.rhel9&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array&nbsp;controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>システム管理者 (root) としてログインし、RPMを<br />ご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p><p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p><p> </p><ul><li># rpm -Uvh  <strong>-</strong>-oldpackage --replacefiles --replacepkgs<strong> </strong>kmod-smartpqi-<version>.rhel9<OSupdate>.x86_64.rpm  </li></ul><p> </p><p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>注記</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p><ul><li># rpm -e kmod-smartpqi-<version>.rhel9<OSupdate>.x86_64.rpm</li></ul><p><strong><u>エンタープライズサポート</u></strong><br />Smartアレイコントローラーのサポートに関しては <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp; <strong>-</strong>-oldpackage --replacefiles --replacepkgs<strong>&nbsp;</strong>kmod-smartpqi-&lt;version&gt;.rhel9&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li></ul><p>&nbsp;</p><p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e kmod-smartpqi-&lt;version&gt;.rhel9&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array&nbsp;controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 10 (64-bit)"},{"Lang":"ja","Value":"HPE ProLiant Gen10、Gen10Plus、およびGen11 Smartアレイコントローラー（64ビット）ドライバーfor Red Hat Enterprise Linux 10 (64ビット)"},{"Lang":"cn","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 10 (64-bit)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T09:41:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added a timeout value to RAID path requests to physical devices.</li></ul>","Fixes":"<ul><li>Fixed an issue where the kernel call trace when calling smp_processor_id() in real-time kernel.&nbsp;</li><li>Fixed an issue of accessing NULL SCSI device pointer caused by a rare race condition.&nbsp;</li><li>Fixed a system crash issue caused by a divide-by-zero condition.&nbsp;</li><li>Fixed an issue where after a device has been removed, it&#39;s possible for a previously scheduled work item for a LUN reset to be executed.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added a timeout value to RAID path requests to physical devices.</li></ul>","Fixes":"<ul><li>リアルタイムカーネルでsmp_processor_id()を呼び出すときにカーネル呼び出しトレースが実行される問題を修正しました。 </li><li>まれな競合状態によって発生するNULL SCSIデバイスポインターへのアクセスの問題を修正しました。 </li><li>ゼロ除算条件によって発生するシステムクラッシュの問題を修正しました。 </li><li>デバイスが削除された後、以前にスケジュールされた LUNリセットの作業項目が実行される可能性がある問題を修正しました。 </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added a timeout value to RAID path requests to physical devices.</li></ul>","Fixes":"<ul><li>Fixed an issue where the kernel call trace when calling smp_processor_id() in real-time kernel.&nbsp;</li><li>Fixed an issue of accessing NULL SCSI device pointer caused by a rare race condition.&nbsp;</li><li>Fixed a system crash issue caused by a divide-by-zero condition.&nbsp;</li><li>Fixed an issue where after a device has been removed, it&#39;s possible for a previously scheduled work item for a LUN reset to be executed.&nbsp;</li></ul>","Lang":"cn"}],"Version":"2.1.36-026"},{"ReleaseNotes":[{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2.1.38-022"}],"SWKeys":[{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"13f5a57fd4bb451c85bc523068e5002b"}]},{"ProductId":"5f7dae044b3b4d97823b1cfc69305837","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.27"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux x86_64 platform."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic NX2 Gigabit Ethernet NICブートコード、MFW、PXE、UEFI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v7.19.27&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>UEFI Version</strong></td><td><strong>iSCSI Version</strong></td><td><strong>FCoE Version</strong></td><td><strong>CCM Version</strong></td><td><strong>L2 Version</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 530SFP+ Adapter<br />HPE Ethernet 10Gb 2-port 530T Adapter</td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>n/a</td><td>n/a</td><td>7.14.4</td><td>7.12.25</td></tr><tr><td><p>HPE Ethernet 10Gb 2-port 533FLR-T Adapter<br />HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter<br />HPE FlexFabric 10Gb 4-port 536FLR-T Adapter</p></td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>7.14.0</td><td>7.14.3</td><td>7.14.4</td><td>7.12.25</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains combo image v7.19.27&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>UEFI Version</strong></td><td><strong>iSCSI Version</strong></td><td><strong>FCoE Version</strong></td><td><strong>CCM Version</strong></td><td><strong>L2 Version</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 530SFP+ Adapter<br />HPE Ethernet 10Gb 2-port 530T Adapter</td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>n/a</td><td>n/a</td><td>7.14.4</td><td>7.12.25</td></tr><tr><td><p>HPE Ethernet 10Gb 2-port 533FLR-T Adapter<br />HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter<br />HPE FlexFabric 10Gb 4-port 536FLR-T Adapter</p></td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>7.14.0</td><td>7.14.3</td><td>7.14.4</td><td>7.12.25</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v7.19.27&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>UEFI Version</strong></td><td><strong>iSCSI Version</strong></td><td><strong>FCoE Version</strong></td><td><strong>CCM Version</strong></td><td><strong>L2 Version</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 530SFP+ Adapter<br />HPE Ethernet 10Gb 2-port 530T Adapter</td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>n/a</td><td>n/a</td><td>7.14.4</td><td>7.12.25</td></tr><tr><td><p>HPE Ethernet 10Gb 2-port 533FLR-T Adapter<br />HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter<br />HPE FlexFabric 10Gb 4-port 536FLR-T Adapter</p></td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>7.14.0</td><td>7.14.3</td><td>7.14.4</td><td>7.12.25</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"3279090","DateModified":"2024-12-11T03:26:28","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/CP064333.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/CP064333.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/nic_fw/hp_mbi_7.19.27.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064333.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064333.scexe"],"MD5Sum":"3c205ad09bbb41cdfb3eb86e1c91cbb6","Name":"firmware-nic-qlogic-nx2-2.37.0-1.1.x86_64.rpm","Release":"2024-12-11T09:18:57","Revision":"","SHA1Sum":"90068aa562bf394f76ab6fa8ec346bb0e3a326c0","SHA256Sum":"e384f4928f9eaebe951691a70ef7285fcd9eb472087f3e12b108311f188e5c7e","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"2.37.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","DeviceGUID":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E3-Ethernet-iSCSI-FCoE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.0.251.0-1OEM.700.1.0.15843807"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","SWKey":"qfle3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.4.51.0-1OEM.700.1.0.15843807"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p><ul><li>ファームウェアrpmパッケージをインストールします。<br /><em>> rpm -ivh <rpm_filename>.rpm </em></li><li>ファイルを抽出する場所を確認します。<br /><em>> rpm -qlp <rpm_filename>.rpm</em></li><li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li></ul><p> </p><p><strong><em>追加情報：</em></strong></p><ul><li>詳細情報はCPxxxxxx.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCPxxxxxx.logに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。 </li><li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"适用于 Linux x86_64 的 HPE QLogic NX2 在线固件升级实用程序"},{"Lang":"ja","Value":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T03:48:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed to prevent BSOD issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed to prevent BSOD issue.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed to prevent BSOD issue.</p>","Lang":"cn"}],"Version":"2.36.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.37.0"}],"SWKeys":[{"Name":"QLOGIC_NX2","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"67291762a5054079aef09cf140b67273"}]},{"ProductId":"435031f572ea43b79bd116d63a99a58a","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57414 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957414A4142HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41597","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957414A4142HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957414A4142HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Version":"235.1.164.14"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 Gigabit Ethernet NIC firmware."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"1384905","DateModified":"2025-12-11T09:24:12","FileList":["BCM235.1.164.14_BCM957414A4142HC.HPb","BCM235.1.164.14_BCM957414A4142HC.xml","payload.json"],"MD5Sum":"c3aae985ee4c718ab0fd3f6d2acb9217","Name":"BCM235.1.164.14_BCM957414A4142HC.fwpkg","Release":"2025-12-11T09:20:29","Revision":"","SHA1Sum":"4a91abed66f581f286aa9196eb98bc5f0185ff74","SHA256Sum":"94594f9ae896feb0cec124d148ab2aa3492e7a2f0c9a38ebd0b560c0f369902e","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41597"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM57414 adapter"},{"Lang":"ja","Value":"Broadcom Firmware Package for BCM57414 adapter"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM57414 adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-11T08:09:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"BCM_NXE_57414_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"17152b23fa524ee88df95b94f1017296"}]},{"ProductId":"4efc4b5fce384054939496405bc41d6b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KXG50PNV2T04","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AFGA4103.sig","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AFGA4103"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Disk"},{"Lang":"ja","Value":"ファームウェア - ストレージ ディスク"},{"Lang":"cn","Value":"固件 - 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: KXG50PNV2T04 Drives that can be installed directly on HPE ProLiant m750 System running a supported Microsoft Windows Operating System installed in HPE Moonshot 1500 chassis."},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: KXG50PNV2T04 Drives that can be installed directly on HPE ProLiant m750 System running a supported Microsoft Windows Operating System installed in HPE Moonshot 1500 chassis."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7647728","DateModified":"2026-01-21T14:47:20","FileList":["AFGA4103.sig","cp070412.xml","cpqsetup.exe","ilorest_chif.dll","payload.json"],"MD5Sum":"28a09523098ea9e84777b2c7013d2eef","Name":"cp070412.exe","Release":"2026-01-21T14:28:38","Revision":"B","SHA1Sum":"9bfe38acc9f10b109968e48dc066227b3ae59624","SHA256Sum":"ba48d54cad492cd5ccfa2e95216da56b0d6e74ad7f07e326351919cb4c82c2f2","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"AFGA4103"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p>"},{"Lang":"ja","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Microsoft Windows - KXG50PNV2T04 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Microsoft Windows - KXG50PNV2T04ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"9000"},"SupportedDevices":[{"Id":"KXG50PNV2T04","TargetGUID":"002340a5-584b-3547-3050-4e5632543034","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"Microsoft Windows 11","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-16T19:01:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"AFGA4103"},{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"AFGA4103"}],"SWKeys":[{"Name":"KXG50PNV2T04","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ac220d665e8c416882baad1fef6a7e59"}]},{"ProductId":"266a0b8481ca4005841140656323155c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."},{"Lang":"ja","Value":"セキュアブートモードでのHPE Mellanox MFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"31335791","DateModified":"2025-10-07T14:40:43","FileList":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/09","./usr/lib/.build-id/09/f109281b8e907068ffd7c1c342858dff784e01","./usr/lib/.build-id/0f","./usr/lib/.build-id/0f/06c107262adada878deb0f9fa83d774f751f48","./usr/lib/.build-id/10","./usr/lib/.build-id/10/0a8c0576f6803c90885f113b58394a44f0a871","./usr/lib/.build-id/10/c7a8c5696bd094204a596bce50b1ba1fb846cb","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/1db7f49eaa674db0f2554468466f00011e0172","./usr/lib/.build-id/2d","./usr/lib/.build-id/2d/758b0ad35a7f5767e77fd249b875d632a45733","./usr/lib/.build-id/39","./usr/lib/.build-id/39/8a0d4dd55e47ce4f6d070acecfdb122289d33f","./usr/lib/.build-id/42","./usr/lib/.build-id/42/aaea6007932f09a5c3309dbc5a5ccc072cf035","./usr/lib/.build-id/48","./usr/lib/.build-id/48/dedbe624bd18afdad53e7f49e678733023b908","./usr/lib/.build-id/4c","./usr/lib/.build-id/4c/35559fa839acc99a9c75a3dc8422b24cf1bda7","./usr/lib/.build-id/51","./usr/lib/.build-id/51/39ebac45d29b13d9165f1f74cda6ff3da41cde","./usr/lib/.build-id/5d","./usr/lib/.build-id/5d/bbdf0b0c073e7be1d04a3e0e647fddddf686e2","./usr/lib/.build-id/60","./usr/lib/.build-id/60/bfe2319a1267622d58682d4f739da72567e8f8","./usr/lib/.build-id/63","./usr/lib/.build-id/63/0048b7ed76eec96328ace78f9397670dfbf39d","./usr/lib/.build-id/64","./usr/lib/.build-id/64/70e23454c94c00d458d330decb11f4bfada781","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/9765d63e6ec7eff0b34d9355ed62c54238c03a","./usr/lib/.build-id/74","./usr/lib/.build-id/74/2fa7fe1af4bc2e5546226ffb413385abe30056","./usr/lib/.build-id/76","./usr/lib/.build-id/76/cddc0af7cf963769c8ae730fd3443ff95fe869","./usr/lib/.build-id/81","./usr/lib/.build-id/81/0aff60310d4da78fcf604ce98bf4d0bb82983b","./usr/lib/.build-id/82","./usr/lib/.build-id/82/c932a3195593bd1f6ff6c462cc7aebe3c64add","./usr/lib/.build-id/85","./usr/lib/.build-id/85/e0ca034196c107f7a88b23cd7af942d9eb2d40","./usr/lib/.build-id/8b","./usr/lib/.build-id/8b/36d15bed3b078dd01aae8ed23fef0552ebdcc3","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/0f00edeff5dd8f8daf3f6d054cac5b30775ada","./usr/lib/.build-id/91","./usr/lib/.build-id/91/34aa2fbe03361af16f037094235b54e2957851","./usr/lib/.build-id/93","./usr/lib/.build-id/93/e20b792c9e9e6b18557e3b4d5741b0f54e8044","./usr/lib/.build-id/ac","./usr/lib/.build-id/ac/30394f6339d378871506935512a61504b6c304","./usr/lib/.build-id/b4","./usr/lib/.build-id/b4/51faf1296981ec859e8d515c8ff9644bfc64ec","./usr/lib/.build-id/b5","./usr/lib/.build-id/b5/0e1c1d7671fc03dcc87f74b4d41893efcadf54","./usr/lib/.build-id/b7","./usr/lib/.build-id/b7/82443d6962db647257a8fb8879cf28fbad0c93","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/3bdd4b85f6928930b1030cba40cee60458d945","./usr/lib/.build-id/bf/5eec04e20f7ffc87fc5b4375658c981df3ac11","./usr/lib/.build-id/c1","./usr/lib/.build-id/c1/326615a196bad2ef9cf7906a82fb301ac3ffd1","./usr/lib/.build-id/c3","./usr/lib/.build-id/c3/af518fbf4f31021d87d31824acaeaf981a4d86","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/d7af687801a418c6cafd69c3d986659039589d","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/840cae88a2719081ace2774afbe4a39a9ff08d","./usr/lib/.build-id/f1","./usr/lib/.build-id/f1/81098d4fef21db82f53346f2045097b4ec8b34","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/cbdaeee8cd3ad8284fdd44f0af6317f466e9de","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/876e7ad783090ff0db05fe68e6ffdbec0348c0","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/ext_libs/libcrypto.so.3","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/gpu_drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/device_info","./usr/share/mft/device_info/json","./usr/share/mft/device_info/json/0x11.json","./usr/share/mft/device_info/json/0x19.json","./usr/share/mft/device_info/json/0x1e.json","./usr/share/mft/device_info/json/0x1f5.json","./usr/share/mft/device_info/json/0x1f7.json","./usr/share/mft/device_info/json/0x1ff.json","./usr/share/mft/device_info/json/0x209.json","./usr/share/mft/device_info/json/0x20b.json","./usr/share/mft/device_info/json/0x20d.json","./usr/share/mft/device_info/json/0x20f.json","./usr/share/mft/device_info/json/0x211.json","./usr/share/mft/device_info/json/0x212.json","./usr/share/mft/device_info/json/0x214.json","./usr/share/mft/device_info/json/0x216.json","./usr/share/mft/device_info/json/0x218.json","./usr/share/mft/device_info/json/0x21c.json","./usr/share/mft/device_info/json/0x21e.json","./usr/share/mft/device_info/json/0x220.json","./usr/share/mft/device_info/json/0x222.json","./usr/share/mft/device_info/json/0x224.json","./usr/share/mft/device_info/json/0x226.json","./usr/share/mft/device_info/json/0x247.json","./usr/share/mft/device_info/json/0x249.json","./usr/share/mft/device_info/json/0x24b.json","./usr/share/mft/device_info/json/0x24d.json","./usr/share/mft/device_info/json/0x24e.json","./usr/share/mft/device_info/json/0x250.json","./usr/share/mft/device_info/json/0x252.json","./usr/share/mft/device_info/json/0x253.json","./usr/share/mft/device_info/json/0x254.json","./usr/share/mft/device_info/json/0x256.json","./usr/share/mft/device_info/json/0x257.json","./usr/share/mft/device_info/json/0x259.json","./usr/share/mft/device_info/json/0x25b.json","./usr/share/mft/device_info/json/0x270.json","./usr/share/mft/device_info/json/0x274.json","./usr/share/mft/device_info/json/0x278.json","./usr/share/mft/device_info/json/0x27c.json","./usr/share/mft/device_info/json/0x282.json","./usr/share/mft/device_info/json/0x288.json","./usr/share/mft/device_info/json/0x2900.json","./usr/share/mft/device_info/json/0x3.json","./usr/share/mft/device_info/json/0x3000.json","./usr/share/mft/device_info/json/0x3480.json","./usr/share/mft/device_info/json/0x6b.json","./usr/share/mft/device_info/json/0x6e.json","./usr/share/mft/device_info/json/0x6f.json","./usr/share/mft/device_info/json/0x70.json","./usr/share/mft/device_info/json/0x71.json","./usr/share/mft/device_info/json/0x72.json","./usr/share/mft/device_info/json/0x73.json","./usr/share/mft/device_info/json/0x7e.json","./usr/share/mft/device_info/json/0x7f.json","./usr/share/mft/device_info/json/0x80.json","./usr/share/mft/device_info/json/0x82.json","./usr/share/mft/device_info/json/0x84.json","./usr/share/mft/device_info/json/0xd.json","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/gpu","./usr/share/mft/prm_dbs/gpu/ext","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers","./usr/share/mft/prm_dbs/retimers/ext","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"MD5Sum":"7fdcbc2c3e4b3efb843d304b4f4fc1ec","Name":"mft-4.33.0-169.rhel9u6.x86_64.rpm","Release":"2025-10-07T14:33:04","Revision":"","SHA1Sum":"59adfc34d2454f6c87e917157353095d8a0b1594","SHA256Sum":"a42b579eda586c5b40bf142bd007ab8e98b19c176d492508072dbfde559a6bb1","Size":"29MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"TypeOfChange":"0","Version":"4.33.0-169"},{"Bytes":"77344","DateModified":"2025-10-07T14:45:52","FileList":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/kernel-mft-mlnx","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"MD5Sum":"f7a6a72a2cdb990c1bcd09e372efe59e","Name":"kmod-kernel-mft-mlnx-4.33.0-1.rhel9u6.x86_64.rpm","Release":"2025-10-07T14:33:04","Revision":"","SHA1Sum":"1c2ffd47b0811a7e4ebdfcacd835a4b6c7594439","SHA256Sum":"e2369425a3e9d0e9a66e9c07a62748f51a007cb8fc1b72a3f2a000053a7cdc23","Size":"75KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"TypeOfChange":"0","Version":"4.33.0-169"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />To install or upgrade the driver:<br /><br />If using kernel version 5.14.0-570.12.1.el9_6.x86_64&nbsp; &nbsp;or any future errata:<br /><strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.33.0-1.rhel9u6.x86_64.rpm&nbsp;&nbsp;mft-4.33.0-169.rhel9u6.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />To install or upgrade the driver:<br /><br />If using kernel version 5.14.0-570.12.1.el9_6.x86_64&nbsp; &nbsp;or any future errata:<br /><strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.33.0-1.rhel9u6.x86_64.rpm&nbsp;&nbsp;mft-4.33.0-169.rhel9u6.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />To install or upgrade the driver:<br /><br />If using kernel version 5.14.0-570.12.1.el9_6.x86_64&nbsp; &nbsp;or any future errata:<br /><strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.33.0-1.rhel9u6.x86_64.rpm&nbsp;&nbsp;mft-4.33.0-169.rhel9u6.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 9 Update 6 (x86_64)"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 Update 6 (x86_64)のセキュアブートモードでのMellanoxアダプターのファームウェアアップデート用のHPE Mellanox MFT前提条件RPM"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 9 Update 6 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-07T12:13:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.32.0-120"},{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.33.0-169"}],"SWKeys":[{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"629df68815684bcd87655dca99d5cf7c"}]},{"ProductId":"8bfd6c84c6a049339ae439f038925df1","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U60_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.52 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17451696","DateModified":"2026-01-13T08:04:22","FileList":["cp070160.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U60_2.52_01_09_2026.signed.flash"],"MD5Sum":"b4717b2c4b7bef8c536804e638d364e5","Name":"cp070160.exe","Release":"2026-01-13T08:01:21","Revision":"","SHA1Sum":"130e45fbd18b72bd6fefa3002d33983a59897960","SHA256Sum":"188ab07bfab2cb8444f1c0b8e2b5234a8adca88fb8bd0530687f2fbd680c4f8e","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.52_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL20 Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T06:07:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.708（2.50_07_25_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_01-09-2026"}],"SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"e0a9f3024b504c6cad7c0bc69a8e2c76"}]},{"ProductId":"ed78d2df04834204b8977e0aaa96c64a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1550376","DateModified":"2025-11-16T12:55:16","FileList":["cp069526.xml","cpqsetup.exe","cp_data.xml","i40eb68.cat","i40eb68.din","i40eb68.inf","i40eb68.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"3ef44669597e08d60f60f858f86f3bbf","Name":"cp069526.exe","Release":"2025-11-16T12:41:05","Revision":"B","SHA1Sum":"66382020694faa2a4c5401c5e47ad24287b996db","SHA256Sum":"b70eb51da3545f28a6683c241ab6c937885c96b32ff3d576751a980f87bd07c4","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520"],"TypeOfChange":"1","Version":"1.22.86.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40eb Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel i40ebドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel i40eb Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:02:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"cn"}],"Version":"1.22.86.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"cn"}],"Version":"1.22.86.0"}],"SWKeys":[{"Name":"i40eb68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4021bcf03a3e4c79a66a98e6c676685a"}]},{"ProductId":"fc28c0050f9d4a8a94e83f990b230b39","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for&nbsp;VMware ESXi -&nbsp;&nbsp;VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives.<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul><p><strong>Known Issues:</strong></p><ul><li><strong>&nbsp;</strong>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO5 version older than v2.30</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for&nbsp;VMware ESXi -&nbsp;&nbsp;VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives.<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul><p><strong>Known Issues:</strong></p><ul><li><strong>&nbsp;</strong>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO5 version older than v2.30</li></ul>"}],"Files":[{"Bytes":"23262000","DateModified":"2025-08-12T05:01:04","FileList":["/CP068070_BUILD_1.data","/CP068070.vmexe64","/CP068070.vmfile","/CP068070_VMw.zip","/CP068070.xml","/payload.json","/CP068070_VMw.zip/index.xml","/CP068070_VMw.zip/vendor-index.xml","/CP068070_VMw.zip/metadata.zip","/CP068070_VMw.zip/vib20/CP068070/HPE_bootbank_CP068070_85032G00.1-8.0.0.20613240.vib","/CP068070_VMw.zip/metadata.zip/vendor-index.xml","/CP068070_VMw.zip/metadata.zip/vmware.xml","/CP068070_VMw.zip/metadata.zip/vibs/CP068070--153903435134214806.xml","/CP068070_VMw.zip/metadata.zip/bulletins/Smart-Component-CP068070_85032G00.1-8.0.0.20613240.xml"],"MD5Sum":"a004f8809a526c8d4cbf40e5291ff35d","Name":"CP068070.zip","Release":"2025-08-12T05:00:14","Revision":"F","SHA1Sum":"daf03750b4ea8cd658f8055b559989af59613f19","SHA256Sum":"ddd374d172236471109b55e4bd815d6af6cd9dcb1fc83102fafd0b4e3fcd96a3","Size":"22MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00","VibList":[{"Name":"CP068070","Version":"85032G00.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP042969.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VS003840KWXFQ","TargetGUID":"562340a5-3053-3330-3834-304b57584651","Type":"nvme"},{"Id":"VS001920KWXFP","TargetGUID":"562340a5-3053-3130-3932-304b57584650","Type":"nvme"},{"Id":"VS000960KWXFN","TargetGUID":"562340a5-3053-3030-3936-304b5758464e","Type":"nvme"},{"Id":"VS000480KXALB","TargetGUID":"562340a5-3053-3030-3438-304b58414c42","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-04T13:05:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"85032G00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix drive flash issue when drive behind the controller in a specific scenario.</li></ul>","Lang":"cn"}],"Version":"85032G00"}],"SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b8457b1f53d44a82aa36c0ab5d8b9619"}]},{"ProductId":"9fd1abd8973f4c09aa450e541dc4ee41","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5609404","DateModified":"2025-09-21T21:40:12","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/CP068922.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/KARM5ALSHPD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068922.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068922.scexe"],"MD5Sum":"484c10e7b1a1fb0bfca5ae584f5f6bf7","Name":"firmware-hdd-8fafc9efb2-HPD8-5.1.x86_64.rpm","Release":"2025-09-22T02:29:58","Revision":"E","SHA1Sum":"667073d8caeb03a11e92bcfa3902861b96a70bbd","SHA256Sum":"55113065e28e63c620ccf59b18253b23a39944acb7538de114d674b8b8619792","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP041555.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO007680RWUFC","TargetGUID":"562340a5-304f-3730-3638-305257554643","Type":"sas"},{"Id":"VO003840RWUFF","TargetGUID":"562340a5-304f-3330-3834-305257554646","Type":"sas"},{"Id":"VO003840RWUFB","TargetGUID":"562340a5-304f-3330-3834-305257554642","Type":"sas"},{"Id":"VO001920RWUFE","TargetGUID":"562340a5-304f-3130-3932-305257554645","Type":"sas"},{"Id":"VO001920RWUFA","TargetGUID":"562340a5-304f-3130-3932-305257554641","Type":"sas"},{"Id":"VO000960RWUFD","TargetGUID":"562340a5-304f-3030-3936-305257554644","Type":"sas"},{"Id":"VO000960RWUEV","TargetGUID":"562340a5-304f-3030-3936-305257554556","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:04:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d983b2865074432aa1669f5c011e58ff"}]},{"ProductId":"205e86b4ae1e4a28ae1e3cf39faf17ba","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5778350","DateModified":"2025-09-21T22:38:19","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/CP068937.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/SCIMARRNNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068937.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068937.scexe"],"MD5Sum":"1b04c66f708537ada1019762cbdb0d90","Name":"firmware-hdd-12304c1aca-HPG6-6.1.x86_64.rpm","Release":"2025-09-22T03:27:49","Revision":"F","SHA1Sum":"37516b67c70e4d7b7b2a7de23a8b1d431da3cac2","SHA256Sum":"0f289e6023ec56dc97fdf3b086eb1ef5e2bebd0b3fd03c46c3a7a7996ac75502","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP043255.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000GWWQH","TargetGUID":"4d2340a5-3042-3430-3030-304757575148","Type":"sata"},{"Id":"MB002000GWWQF","TargetGUID":"4d2340a5-3042-3230-3030-304757575146","Type":"sata"},{"Id":"MB001000GWWQE","TargetGUID":"4d2340a5-3042-3130-3030-304757575145","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:18:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul>","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"aeeaaa3ea8b3407f9705db0c962f269a"}]},{"ProductId":"6e357a862ebf4f379b5f531a7eb46680","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SPSGen10Plus_04.04.04.802.signed.bin","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.802"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8410597","DateModified":"2025-08-04T09:02:15","FileList":["payload.json","SPSGen10Plus_04.04.04.802.signed.bin","SPSGen10Plus_04.04.04.802.xml"],"MD5Sum":"81e704ad0ae8e50a9099350abebb461b","Name":"SPSGen10Plus_04.04.04.802.fwpkg","Release":"2025-08-04T08:59:51","Revision":"","SHA1Sum":"b8f75fcc55625c230d0edd59cf9b2879527eb16e","SHA256Sum":"a32715d62e194e57e7965e41a194f319a3ac9370d5eff7600c7fd8ec773f19ab","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.802"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェアfor HPE Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-30T01:48:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.04.04.702 (2.30_01_06_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.04.04.702"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"04.04.04.802"}],"SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"46aee4f591d24444a982cbadae0904ba"}]},{"ProductId":"c5274a8d3e3e40d790c226da85bd84aa","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"18400976","DateModified":"2025-03-06T14:35:54","FileList":["/CP065970_BUILD_4.data","/CP065970.vmexe64","/CP065970.vmfile","/CP065970_VMw.zip","/CP065970.xml","/payload.json","/CP065970_VMw.zip/index.xml","/CP065970_VMw.zip/vendor-index.xml","/CP065970_VMw.zip/metadata.zip","/CP065970_VMw.zip/vib20/CP065970/HPE_bootbank_CP065970_HPG7.4-8.0.0.20613240.vib","/CP065970_VMw.zip/metadata.zip/vendor-index.xml","/CP065970_VMw.zip/metadata.zip/vmware.xml","/CP065970_VMw.zip/metadata.zip/vibs/CP065970-1680710732244043349.xml","/CP065970_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065970_HPG7.4-8.0.0.20613240.xml"],"MD5Sum":"ba1ed029a493c7db63e66fb9814b826f","Name":"CP065970.zip","Release":"2025-03-06T14:35:09","Revision":"D","SHA1Sum":"d2eb2c278f6486df0269bb49661e7c1500e4c44a","SHA256Sum":"ecbf6bfeb6278d052578be6ee27d6fa89990434ab1101cac024fa9c089959827","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7","VibList":[{"Name":"CP065970","Version":"HPG7.4-8.0.0.20613240"}]}],"Installation":{"Command":"CP040790.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWTSV、 VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK003840GWTTD","TargetGUID":"562340a5-304b-3330-3834-304757545444","Type":"sata"},{"Id":"MK003840GWTTN","TargetGUID":"4d2340a5-304b-3330-3834-30475754544e","Type":"sata"},{"Id":"VK001920GWTTC","TargetGUID":"562340a5-304b-3130-3932-304757545443","Type":"sata"},{"Id":"MK001920GWTTL","TargetGUID":"4d2340a5-304b-3130-3932-30475754544c","Type":"sata"},{"Id":"VK000960GWTTB","TargetGUID":"562340a5-304b-3030-3936-304757545442","Type":"sata"},{"Id":"MK000960GWTTK","TargetGUID":"4d2340a5-304b-3030-3936-30475754544b","Type":"sata"},{"Id":"VK000480GWTTA","TargetGUID":"562340a5-304b-3030-3438-304757545441","Type":"sata"},{"Id":"MK000480GWTTH","TargetGUID":"4d2340a5-304b-3030-3438-304757545448","Type":"sata"},{"Id":"VK000240GWTSV","TargetGUID":"562340a5-304b-3030-3234-304757545356","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:41:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG7"}],"SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9ca3dd9ecb244e43acb9e5fe9d0ec0cb"}]},{"ProductId":"9b11c8b2e5814a11b64b738755f0d8ce","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b594c4543","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b594c484c","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b594c484e","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b594c4542","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b594c4846","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b594c4848","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3531-3336-304b594c484b","Version":"HPK1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600KYLEC, MO003200KYLHL, MO006400KYLHN, VO001920KYLEB, VO003840KYLHF, VO007680KYLHH and VO015360KYLHK"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO001600KYLEC, MO003200KYLHL, MO006400KYLHN, VO001920KYLEB, VO003840KYLHF, VO007680KYLHH and VO015360KYLHK"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600KYLEC, MO003200KYLHL, MO006400KYLHN, VO001920KYLEB, VO003840KYLHF, VO007680KYLHH and VO015360KYLHK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; This is a maintenance release that contains code fix improvements and drive function enhancements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; This is a maintenance release that contains code fix improvements and drive function enhancements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; This is a maintenance release that contains code fix improvements and drive function enhancements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"10040511","DateModified":"2025-08-07T21:36:16","FileList":["payload.json","SKHynix_PE10X0_KPE10x0U3DK1.HPb","SKHynix_PE10X0_KPE10x0U3DK1.xml"],"MD5Sum":"fda9ffe65eb7c300ef588b45861b0674","Name":"SKHynix_PE10X0_KPE10x0U3DK1.fwpkg","Release":"2025-08-07T21:33:46","Revision":"","SHA1Sum":"88c4dfb1a9b10a9acce91cdbed993ce1740e38d2","SHA256Sum":"4a97d82fc7852e6d4cca15174ebadae6f5f10c748c3a0d1cfedece46d2f47d7e","Size":"9MB","TargetGUIDs":["4d2340a5-304f-3130-3630-304b594c4543","4d2340a5-304f-3330-3230-304b594c484c","4d2340a5-304f-3630-3430-304b594c484e","562340a5-304f-3130-3932-304b594c4542","562340a5-304f-3330-3834-304b594c4846","562340a5-304f-3730-3638-304b594c4848","562340a5-304f-3531-3336-304b594c484b"],"TypeOfChange":"1","Version":"HPK1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600KYLEC, MO003200KYLHL, MO006400KYLHN, VO001920KYLEB, VO003840KYLHF, VO007680KYLHH and VO015360KYLHK"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MO001600KYLEC, MO003200KYLHL, MO006400KYLHN, VO001920KYLEB, VO003840KYLHF, VO007680KYLHH and VO015360KYLHK"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600KYLEC, MO003200KYLHL, MO006400KYLHN, VO001920KYLEB, VO003840KYLHF, VO007680KYLHH and VO015360KYLHK"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO001600KYLEC","TargetGUID":"4d2340a5-304f-3130-3630-304b594c4543","Type":"nvme"},{"Id":"MO003200KYLHL","TargetGUID":"4d2340a5-304f-3330-3230-304b594c484c","Type":"nvme"},{"Id":"MO006400KYLHN","TargetGUID":"4d2340a5-304f-3630-3430-304b594c484e","Type":"nvme"},{"Id":"VO001920KYLEB","TargetGUID":"562340a5-304f-3130-3932-304b594c4542","Type":"nvme"},{"Id":"VO003840KYLHF","TargetGUID":"562340a5-304f-3330-3834-304b594c4846","Type":"nvme"},{"Id":"VO007680KYLHH","TargetGUID":"562340a5-304f-3730-3638-304b594c4848","Type":"nvme"},{"Id":"VO015360KYLHK","TargetGUID":"562340a5-304f-3531-3336-304b594c484b","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-07T21:13:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code fix improvements and drive function enhancements.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code fix improvements and drive function enhancements.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code fix improvements and drive function enhancements.</li></ul>","Lang":"cn"}],"Version":"HPK1"}],"SWKeys":[{"Name":"MO001600KYLEC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYLHL","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYLHN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYLEB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYLHF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYLHH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYLHK","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"3d2e90b3dab24c458b2fd74f4d437b70"}]},{"ProductId":"b64e2e4187274c5798b3aa127c50ba6a","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U43_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.72 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16821912","DateModified":"2026-01-13T07:10:45","FileList":["payload.json","U43_3.72_01_09_2026.signed.flash","U43_3.72_01_09_2026.xml"],"MD5Sum":"f1990b643ab60385901ce2235a544a06","Name":"U43_3.72_01_09_2026.fwpkg","Release":"2026-01-13T07:08:16","Revision":"","SHA1Sum":"ee8206c410205fec153a867ce495f28f37704ce5","SHA256Sum":"415f055c593aecc633e95c28491f3a79b17ed9f9df6ab7fab4d20f5b3adc71cb","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.72_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL20 Gen10(U43)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL20 Gen10 (U43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T09:33:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.103と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.70_08-08-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_01-09-2026"}],"SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"01734ec4abc34b148237ce4506ef5420"}]},{"ProductId":"6d4e51e8b4c040cc80275ae447831403","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10P and Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID® Gen10 PlusおよびGen11コントローラー製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10P and Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3164328","DateModified":"2025-12-03T21:32:18","FileList":["cp069947.xml","cpqsetup.exe","cp_data.xml","install.xml","multisetup.dll","StorCLI.msi"],"MD5Sum":"290ab4010ce5454ec0577674e983b223","Name":"cp069947.exe","Release":"2025-12-03T21:29:43","Revision":"C","SHA1Sum":"828b5a3ea59fe8c934ca8a856a968e4250dcfb5a","SHA256Sum":"fc6da99248cb183a7950d8de34da8d4fff3f59314133ddecd68db9cc75dbff7e","Size":"3MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b"],"TypeOfChange":"1","Version":"7.3212.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p><p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p><p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\\MR Storage Administrator\\StorCLI\\bin&nbsp;folder and execute Storcli64.exe utility</p><p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバーのWindowsオペレーティングシステムからStorcliユーティリティを実行するには：</strong></p><p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p><p>インストールが完了したら、コマンドプロンプト環境を実行し、%programfiles%\\MR Storage Administrator\\StorCLI\\binフォルダーに移動し、Storcli64.exeユーティリティを実行します</p><p>例えば: <strong>Storcli64.exe /c0 show </strong></p>"},{"Lang":"cn","Value":"<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p><p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p><p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\\MR Storage Administrator\\StorCLI\\bin&nbsp;folder and execute Storcli64.exe utility</p><p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit (for Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator StorCLI for Windows 64ビット (Gen10PおよびGen11コントローラー用)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit (for Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-01T03:11:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加<ul><li>コマンド: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.3212.0.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Fix windows run timeout issue..</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Fix windows run timeout issue..</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Fix windows run timeout issue..</li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.3212.0.0"}],"SWKeys":[{"Name":"storcli64.exe","SWKeyExpectedPath":"%programfiles%\\MR Storage Administrator\\StorCLI\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a341292c7bd644edbcd628ce17848c04"}]},{"ProductId":"7af1785af4fd43e38986cbbadda39482","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"9861849","DateModified":"2025-09-21T20:34:26","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/CP068915.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/MPK7825Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068915.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068915.scexe"],"MD5Sum":"b330092e8b96d1abfbcc0503ff0e7694","Name":"firmware-hdd-951aefd63e-MPK7825Q-6.1.x86_64.rpm","Release":"2025-09-22T01:24:35","Revision":"F","SHA1Sum":"e104b26a880d4d30af200bc6fdd0912905b2c932","SHA256Sum":"38a96575f91b2ebf28e56cc1ef947119f00cf3eb99842324c1c351cc1c7c0361","Size":"9MB","TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3 Drive"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3 Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXLR12THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3132-544869b8df72","Type":"nvme"},{"Id":"MZXLR15THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3135-5448e88a517e","Type":"nvme"},{"Id":"MZXLR7T6HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3754-36484bc80db1","Type":"nvme"},{"Id":"MZXLR1T6HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Type":"nvme"},{"Id":"MZXLR800HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3830-3048c3876295","Type":"nvme"},{"Id":"MZXLR3T2HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3248a4bea716","Type":"nvme"},{"Id":"MZXLR6T4HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Type":"nvme"},{"Id":"MZXLR1T9HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3948cda93afa","Type":"nvme"},{"Id":"MZXLR3T8HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3848df400867","Type":"nvme"},{"Id":"MZXLR960HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3936-3048d2d64915","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:55:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"MPK7825Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK7825Q"}],"SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3c7883e497ac44e0bd4a809faf8f5003"}]},{"ProductId":"e528a2af212b4bb09bfd3cb54b985653","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5097014","DateModified":"2025-09-17T04:04:54","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/CP068825.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/Eaglescanyon-Release-0.39.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068825.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068825.scexe"],"MD5Sum":"db6bee5d15b3b04e5cc50724cbc2f611","Name":"firmware-smartarray-f36d4ef431-0.39-8.1.x86_64.rpm","Release":"2025-09-17T08:51:53","Revision":"H","SHA1Sum":"872ff0bb863964a87047485163fac701d47e0f3f","SHA256Sum":"4c1b76c1cf88cad95a8abe4cb096bcfb99a15c836e040343463ae8abcc3bc41a","Size":"4MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"Installation":{"Command":"CP068825.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>次のコマンドを使用してファームウェアrpmをインストールします：  rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em> <rpm_filename>  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します</li><li>CPXXXXXX.scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-smartarray-f36d4ef431-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'にある./CPXXXXXX.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*'にある<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em> ('.rpm'拡張子の付いていないrpmファイル名) を実行します。</li></ul><p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id  </em>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-f36d4ef431-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong><em>追加情報:</em></strong></p><p>ファームウェアrpmパッケージのインストール (rpm -ivh) は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p> </p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong></p><p><strong>オフライン：</strong></p><ul><li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/SPPxxxxxxx/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートに必要なファームウェアを/SPPxxxxxxx/packagesディレクトリにコピーします。</li><li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーファームウェア"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-10-16T07:03:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"0.39"},{"ReleaseNotes":[{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"cn"}],"Version":"0.39"}],"SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ca06346fe34e428ca900a93a55162a81"}]},{"ProductId":"7cb9f47fb1de402da9399ef94a8426a5","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08SDAeD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a575a5651","Version":"HPD3"},{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08SDAeD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a575a5652","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model:  MB006000JWZVQ and MB008000JWZVR"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB006000JWZVQおよびMB008000JWZVR"},{"Lang":"cn","Value":"This package provides firmware for the following drive model:  MB006000JWZVQ and MB008000JWZVR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; </strong>N/A<br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; </strong>N/A<br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; </strong>N/A<br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"}],"Files":[{"Bytes":"1311475","DateModified":"2025-02-19T21:07:21","FileList":["payload.json","Toshiba_MG08Air_TAMG08SDAeD3.HPb","Toshiba_MG08Air_TAMG08SDAeD3.xml"],"MD5Sum":"f523c1f7b1d48fd5037d45968bee5c6f","Name":"Toshiba_MG08Air_TAMG08SDAeD3.fwpkg","Release":"2025-02-19T21:04:31","Revision":"B","SHA1Sum":"cb4c724156dd68463a38c4c5237d5a89304ec792","SHA256Sum":"3a7bc5c43a9b028ffdcfac3fd987424486bc86afd1de644f403f99c8ded78ef7","Size":"1MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a575a5651","4d2340a5-3042-3830-3030-304a575a5652"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MB006000JWZVQ and MB008000JWZVR"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MB006000JWZVQおよびMB008000JWZVR"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MB006000JWZVQ and MB008000JWZVR"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB006000JWZVQ","TargetGUID":"4d2340a5-3042-3630-3030-304a575a5651","Type":"sas"},{"Id":"MB008000JWZVR","TargetGUID":"4d2340a5-3042-3830-3030-304a575a5652","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T21:04:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions..</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。  このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions..</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB006000JWZVQ","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB008000JWZVR","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"6927e5439b7746e3bda2359045abc5bb"}]},{"ProductId":"ae4ca58542c143b088e01d17c537b7ac","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKLおよび、MB018000JYDKN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None &nbsp;</p><p><strong>Problems Fixed:</strong></p><ul><li>A Drive Firmware enhancement has been made for&nbsp;&nbsp;Primera 600 products&nbsp;to reduce the probability of infrequent, unexpected power loss on some backed drives.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None &nbsp;</p><p><strong>Problems Fixed:</strong></p><ul><li>A Drive Firmware enhancement has been made for&nbsp;&nbsp;Primera 600 products&nbsp;to reduce the probability of infrequent, unexpected power loss on some backed drives.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20302221","DateModified":"2025-05-27T12:58:18","FileList":["/CP067287_BUILD_1.data","/CP067287.vmexe64","/CP067287.vmfile","/CP067287_VMw.zip","/CP067287.xml","/payload.json","/CP067287_VMw.zip/index.xml","/CP067287_VMw.zip/vendor-index.xml","/CP067287_VMw.zip/metadata.zip","/CP067287_VMw.zip/vib20/CP067287/HPE_bootbank_CP067287_HPD6.1-8.0.0.20613240.vib","/CP067287_VMw.zip/metadata.zip/vendor-index.xml","/CP067287_VMw.zip/metadata.zip/vmware.xml","/CP067287_VMw.zip/metadata.zip/vibs/CP067287-3549365858165177525.xml","/CP067287_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067287_HPD6.1-8.0.0.20613240.xml"],"MD5Sum":"c69b7283e2eb0ee0e1bbebfcef453f99","Name":"CP067287.zip","Release":"2025-05-27T12:57:24","Revision":"C","SHA1Sum":"f6a00bf5b4be835f42e1e98dd3296d22003ec364","SHA256Sum":"c931d7c81314520960173c91444612505c0b2e626be58d6e9a7a5c9fe26024a8","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP067287","Version":"HPD6.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP058615.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKL、およびMB018000JYDKNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB010000JYDKK","TargetGUID":"4d2340a5-3042-3031-3030-304a59444b4b","Type":"sas"},{"Id":"MB012000JYCJF","TargetGUID":"4d2340a5-3042-3231-3030-304a59434a46","Type":"sas"},{"Id":"MB014000JYCJV","TargetGUID":"4d2340a5-3042-3431-3030-304a59434a56","Type":"sas"},{"Id":"MB016000JYDKL","TargetGUID":"4d2340a5-3042-3631-3030-304a59444b4c","Type":"sas"},{"Id":"MB018000JYDKN","TargetGUID":"4d2340a5-3042-3831-3030-304a59444b4e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-21T07:17:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made for&nbsp;&nbsp;Primera 600 products&nbsp;to reduce the probability of infrequent, unexpected power loss on some backed drives.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made for&nbsp;&nbsp;Primera 600 products&nbsp;to reduce the probability of infrequent, unexpected power loss on some backed drives.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made for&nbsp;&nbsp;Primera 600 products&nbsp;to reduce the probability of infrequent, unexpected power loss on some backed drives.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"63f3feb49383491f82800884c429d684"}]},{"ProductId":"182450d5bced417a85db3271254808a7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9</p><p><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9</p><p><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3673944","DateModified":"2025-11-17T06:26:16","FileList":["cp068662.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SAVNGSDA.rel","setup.dll"],"MD5Sum":"144994125052cfd59c743f2f63800590","Name":"cp068662.exe","Release":"2025-11-17T06:19:53","Revision":"F","SHA1Sum":"e8cd9f109161b4bd631631f87b9bc3abab3faac9","SHA256Sum":"681518552efe387e8e6175f42a0ff2c7dbf3edbd3603db21034c320196162f4b","Size":"3MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"TypeOfChange":"1","Version":"HPDA"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JEFRB and MM2000JEFRC Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MM1000JEFRB","TargetGUID":"002340a5-4d00-314d-3030-304a45465242","Type":"sas"},{"Id":"MM2000JEFRC","TargetGUID":"002340a5-4d00-324d-3030-304a45465243","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:58:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDA"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"MM1000JEFRB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MM2000JEFRC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a6606c46ecfa49b9a3d5804df3fd45b1"}]},{"ProductId":"d9b51eadf7e440fc88f26963aec59690","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp067923.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2646728","DateModified":"2025-11-14T06:26:13","FileList":["cp067923.compsig","cp067923.zip","cp069639.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"57da902ad7f3366b58ac862c448c01af","Name":"cp069639.exe","Release":"2025-11-14T06:24:27","Revision":"B","SHA1Sum":"f83d771619998cbbffc9b0f1db4c16e71d908d8b","SHA256Sum":"0376f3e0229b4158701c8bfb08bef8efe9e5d7e0e5a83e120327a0ed8a26b413","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T06:19:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 05.01.05.103は、システムROM 3.70 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Server Platform Servicesファームウェアのこのリビジョンは、CVE-2025-20067として文書化されているセキュリティ上の脆弱性を緩和します。この問題は、HPEサーバーに固有のものではありません。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"05.01.05.103"},{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 05.01.05.103は、システムROM 3.70 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Server Platform Servicesファームウェアのこのリビジョンは、CVE-2025-20067として文書化されているセキュリティ上の脆弱性を緩和します。この問題は、HPEサーバーに固有のものではありません。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU 2025.3 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 05.01.05.103 should be paired with System ROM 3.70 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2025-20067. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"05.01.05.103"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"947c2aba9257407c8bad37d9c29a4a05"}]},{"ProductId":"39b3bcd8f8b243ad9879002d6ba846cc","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"18216980","DateModified":"2025-07-16T07:23:30","FileList":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"MD5Sum":"7c720b0cd8a84d91d5f3ff27c233c43c","Name":"qlgc-fastlinq-kmp-default-8.76.2.0_k6.4.0_150700.51-11.sles15sp7.x86_64.rpm","Release":"2025-07-16T06:57:43","Revision":"","SHA1Sum":"010e0c350535ed86b3caa00fb57cde40d71dae14","SHA256Sum":"ba00540407f05e72223f4855783d1d076df273b190b9421e91b16d10387768db","Size":"17MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.76.2.0-11"},{"Bytes":"18130839","DateModified":"2025-07-16T07:31:25","FileList":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"MD5Sum":"2d15abbcb02f43fb4cfea9c547739155","Name":"qlgc-fastlinq-kmp-default-8.76.2.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-07-16T06:57:43","Revision":"","SHA1Sum":"ee4550ecfcafe5ce50902a752ff9d05f92db870a","SHA256Sum":"a2675662da718441ca4d14553d70c2ac9228c175be2197e6d008679a5afab37c","Size":"17MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.76.2.0-11"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"SUSE Linux Enterprise Server 15用HPE QLogic FastLinQ 10/25/50 GbEドライバー"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770070","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770069","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770068","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770071","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770072","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770074","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770073","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-16T06:55:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue of PTP hardware timestamp does not function.</li><li>This product fixes an error while reading debugfs attribute do_not_recover.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、PTPハードウェアタイムスタンプが機能しない問題を修正します。</li><li>この製品は、debugfs 属性 do_not_recover の読み取り中に発生するエラーを修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue of PTP hardware timestamp does not function.</li><li>This product fixes an error while reading debugfs attribute do_not_recover.</li></ul>","Lang":"cn"}],"Version":"8.74.6.0-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.76.2.0-11"}],"SWKeys":[{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"245785cf99294ae1b2fef1d5cd3cdaa9"}]},{"ProductId":"7e6f42aebfdb4390968da43b36518880","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3249320","DateModified":"2025-11-15T04:35:19","FileList":["cp068760.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA14SXe0HPD9.REL"],"MD5Sum":"2af3a5f9814bf5bd639cfc92a2e3c610","Name":"cp068760.exe","Release":"2025-11-15T04:30:29","Revision":"B","SHA1Sum":"5a4ee195be282872096af18bbed29f8d53eea0a2","SHA256Sum":"d4d7060a9f483f2a3f5950e781ff0ae29d0ee6d01e9175d2ee166b369c3988c5","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPK and EH000600JWHPH  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EH000600JWHPH","TargetGUID":"452340a5-3048-3030-3630-304a57485048","Type":"sas"},{"Id":"EH000900JWHPK","TargetGUID":"452340a5-3048-3030-3930-304a5748504b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T09:18:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスの改訂により、ドライブ全体のパフォーマンスが向上します。</li><li>このファームウェアにアップグレードしない場合、特定のエラーおよびタイミング条件下でドライブがハングアップする可能性が高まります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>このメンテナンスの改訂により、ドライブ全体のパフォーマンスが向上します。</li><li>このファームウェアにアップグレードしない場合、特定のエラーおよびタイミング条件下でドライブがハングアップする可能性が高まります。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6747a7568d794cf59f59ca86ecccf2c1"}]},{"ProductId":"97767c71fca94cd4b046456f83c3475c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."},{"Lang":"ja","Value":"セキュアブートモードでのHPE Mellanox MFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"78194","DateModified":"2025-10-07T15:58:17","FileList":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/kernel-mft-mlnx","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"MD5Sum":"f2ddfd7e5bab53588c69111fefed2c67","Name":"kmod-kernel-mft-mlnx-4.33.0-1.rhel10u0.x86_64.rpm","Release":"2025-10-07T15:51:22","Revision":"","SHA1Sum":"359b49ff22414710b02411098914d4e98baeb533","SHA256Sum":"e322e07f3b72240745be2b4916beb6e3a570aba378f51507a053739d442dac61","Size":"76KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.33.0-169"},{"Bytes":"31304899","DateModified":"2025-10-07T16:02:51","FileList":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/09","./usr/lib/.build-id/09/f109281b8e907068ffd7c1c342858dff784e01","./usr/lib/.build-id/0f","./usr/lib/.build-id/0f/06c107262adada878deb0f9fa83d774f751f48","./usr/lib/.build-id/10","./usr/lib/.build-id/10/0a8c0576f6803c90885f113b58394a44f0a871","./usr/lib/.build-id/10/c7a8c5696bd094204a596bce50b1ba1fb846cb","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/1db7f49eaa674db0f2554468466f00011e0172","./usr/lib/.build-id/2d","./usr/lib/.build-id/2d/758b0ad35a7f5767e77fd249b875d632a45733","./usr/lib/.build-id/39","./usr/lib/.build-id/39/8a0d4dd55e47ce4f6d070acecfdb122289d33f","./usr/lib/.build-id/42","./usr/lib/.build-id/42/aaea6007932f09a5c3309dbc5a5ccc072cf035","./usr/lib/.build-id/48","./usr/lib/.build-id/48/dedbe624bd18afdad53e7f49e678733023b908","./usr/lib/.build-id/4c","./usr/lib/.build-id/4c/35559fa839acc99a9c75a3dc8422b24cf1bda7","./usr/lib/.build-id/51","./usr/lib/.build-id/51/39ebac45d29b13d9165f1f74cda6ff3da41cde","./usr/lib/.build-id/5d","./usr/lib/.build-id/5d/bbdf0b0c073e7be1d04a3e0e647fddddf686e2","./usr/lib/.build-id/60","./usr/lib/.build-id/60/bfe2319a1267622d58682d4f739da72567e8f8","./usr/lib/.build-id/63","./usr/lib/.build-id/63/0048b7ed76eec96328ace78f9397670dfbf39d","./usr/lib/.build-id/64","./usr/lib/.build-id/64/70e23454c94c00d458d330decb11f4bfada781","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/9765d63e6ec7eff0b34d9355ed62c54238c03a","./usr/lib/.build-id/74","./usr/lib/.build-id/74/2fa7fe1af4bc2e5546226ffb413385abe30056","./usr/lib/.build-id/76","./usr/lib/.build-id/76/cddc0af7cf963769c8ae730fd3443ff95fe869","./usr/lib/.build-id/81","./usr/lib/.build-id/81/0aff60310d4da78fcf604ce98bf4d0bb82983b","./usr/lib/.build-id/82","./usr/lib/.build-id/82/c932a3195593bd1f6ff6c462cc7aebe3c64add","./usr/lib/.build-id/85","./usr/lib/.build-id/85/e0ca034196c107f7a88b23cd7af942d9eb2d40","./usr/lib/.build-id/8b","./usr/lib/.build-id/8b/36d15bed3b078dd01aae8ed23fef0552ebdcc3","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/0f00edeff5dd8f8daf3f6d054cac5b30775ada","./usr/lib/.build-id/91","./usr/lib/.build-id/91/34aa2fbe03361af16f037094235b54e2957851","./usr/lib/.build-id/93","./usr/lib/.build-id/93/e20b792c9e9e6b18557e3b4d5741b0f54e8044","./usr/lib/.build-id/ac","./usr/lib/.build-id/ac/30394f6339d378871506935512a61504b6c304","./usr/lib/.build-id/b4","./usr/lib/.build-id/b4/51faf1296981ec859e8d515c8ff9644bfc64ec","./usr/lib/.build-id/b5","./usr/lib/.build-id/b5/0e1c1d7671fc03dcc87f74b4d41893efcadf54","./usr/lib/.build-id/b7","./usr/lib/.build-id/b7/82443d6962db647257a8fb8879cf28fbad0c93","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/3bdd4b85f6928930b1030cba40cee60458d945","./usr/lib/.build-id/bf/5eec04e20f7ffc87fc5b4375658c981df3ac11","./usr/lib/.build-id/c1","./usr/lib/.build-id/c1/326615a196bad2ef9cf7906a82fb301ac3ffd1","./usr/lib/.build-id/c3","./usr/lib/.build-id/c3/af518fbf4f31021d87d31824acaeaf981a4d86","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/d7af687801a418c6cafd69c3d986659039589d","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/840cae88a2719081ace2774afbe4a39a9ff08d","./usr/lib/.build-id/f1","./usr/lib/.build-id/f1/81098d4fef21db82f53346f2045097b4ec8b34","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/cbdaeee8cd3ad8284fdd44f0af6317f466e9de","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/876e7ad783090ff0db05fe68e6ffdbec0348c0","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/ext_libs/libcrypto.so.3","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/gpu_drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/device_info","./usr/share/mft/device_info/json","./usr/share/mft/device_info/json/0x11.json","./usr/share/mft/device_info/json/0x19.json","./usr/share/mft/device_info/json/0x1e.json","./usr/share/mft/device_info/json/0x1f5.json","./usr/share/mft/device_info/json/0x1f7.json","./usr/share/mft/device_info/json/0x1ff.json","./usr/share/mft/device_info/json/0x209.json","./usr/share/mft/device_info/json/0x20b.json","./usr/share/mft/device_info/json/0x20d.json","./usr/share/mft/device_info/json/0x20f.json","./usr/share/mft/device_info/json/0x211.json","./usr/share/mft/device_info/json/0x212.json","./usr/share/mft/device_info/json/0x214.json","./usr/share/mft/device_info/json/0x216.json","./usr/share/mft/device_info/json/0x218.json","./usr/share/mft/device_info/json/0x21c.json","./usr/share/mft/device_info/json/0x21e.json","./usr/share/mft/device_info/json/0x220.json","./usr/share/mft/device_info/json/0x222.json","./usr/share/mft/device_info/json/0x224.json","./usr/share/mft/device_info/json/0x226.json","./usr/share/mft/device_info/json/0x247.json","./usr/share/mft/device_info/json/0x249.json","./usr/share/mft/device_info/json/0x24b.json","./usr/share/mft/device_info/json/0x24d.json","./usr/share/mft/device_info/json/0x24e.json","./usr/share/mft/device_info/json/0x250.json","./usr/share/mft/device_info/json/0x252.json","./usr/share/mft/device_info/json/0x253.json","./usr/share/mft/device_info/json/0x254.json","./usr/share/mft/device_info/json/0x256.json","./usr/share/mft/device_info/json/0x257.json","./usr/share/mft/device_info/json/0x259.json","./usr/share/mft/device_info/json/0x25b.json","./usr/share/mft/device_info/json/0x270.json","./usr/share/mft/device_info/json/0x274.json","./usr/share/mft/device_info/json/0x278.json","./usr/share/mft/device_info/json/0x27c.json","./usr/share/mft/device_info/json/0x282.json","./usr/share/mft/device_info/json/0x288.json","./usr/share/mft/device_info/json/0x2900.json","./usr/share/mft/device_info/json/0x3.json","./usr/share/mft/device_info/json/0x3000.json","./usr/share/mft/device_info/json/0x3480.json","./usr/share/mft/device_info/json/0x6b.json","./usr/share/mft/device_info/json/0x6e.json","./usr/share/mft/device_info/json/0x6f.json","./usr/share/mft/device_info/json/0x70.json","./usr/share/mft/device_info/json/0x71.json","./usr/share/mft/device_info/json/0x72.json","./usr/share/mft/device_info/json/0x73.json","./usr/share/mft/device_info/json/0x7e.json","./usr/share/mft/device_info/json/0x7f.json","./usr/share/mft/device_info/json/0x80.json","./usr/share/mft/device_info/json/0x82.json","./usr/share/mft/device_info/json/0x84.json","./usr/share/mft/device_info/json/0xd.json","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/gpu","./usr/share/mft/prm_dbs/gpu/ext","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers","./usr/share/mft/prm_dbs/retimers/ext","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"MD5Sum":"08ec93589651420e9285b67e2fdb3139","Name":"mft-4.33.0-169.rhel10u0.x86_64.rpm","Release":"2025-10-07T15:51:22","Revision":"","SHA1Sum":"14f07d78804fa72992e64b02c6fbb582d471d163","SHA256Sum":"df581876fb93ff7b772abed1e4a933c58feae485d1cde9f2a2b5d86d34c3073b","Size":"29MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.33.0-169"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />To install or upgrade the driver:<br /><br />If using kernel version 6.12.0-55.9.1.el10.x86_64&nbsp;or any future errata:<br /><strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.33.0-1.rhel10u0.x86_64.rpm&nbsp;&nbsp;mft-4.33.0-169.rhel10u0.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />To install or upgrade the driver:<br /><br />If using kernel version 6.12.0-55.9.1.el10.x86_64&nbsp;or any future errata:<br /><strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.33.0-1.rhel10u0.x86_64.rpm&nbsp;&nbsp;mft-4.33.0-169.rhel10u0.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />To install or upgrade the driver:<br /><br />If using kernel version 6.12.0-55.9.1.el10.x86_64&nbsp;or any future errata:<br /><strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.33.0-1.rhel10u0.x86_64.rpm&nbsp;&nbsp;mft-4.33.0-169.rhel10u0.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 10 Update 0 (x86_64)"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 10 Update 0 (x86_64)のセキュアブートモードでのMellanoxアダプターのファームウェアアップデート用のHPE Mellanox MFT前提条件RPM"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 10 Update 0 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-07T12:13:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.32.0-120"},{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.33.0-169"}],"SWKeys":[{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7fc799bdc4414e2a9c017dcdd10cddd1"}]},{"ProductId":"0300daf553df4e699178bc1f12267a1f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Controller"},{"Lang":"ja","Value":"ソフトウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"软件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID®製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17022064","DateModified":"2025-08-19T10:13:23","FileList":["/BCM-storcli_007.3212.0000.0000-02.zip","/BCM_bootbank_storcli_007.3212.0000.0000-02.vib","/cp067757.xml","/BCM-storcli_007.3212.0000.0000-02.zip/index.xml","/BCM-storcli_007.3212.0000.0000-02.zip/vendor-index.xml","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip","/BCM-storcli_007.3212.0000.0000-02.zip/vib20/storcli/BCM_bootbank_storcli_007.3212.0000.0000-02.vib","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip/vibs/storcli--8585630826784091899.xml","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip/bulletins/BCM-storcli_007.3212.0000.0000-02.xml"],"MD5Sum":"1c861e73de958a77544269ba7652ffc5","Name":"cp067757.zip","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"a69496cd181c48df860a81b0988757708e8d5a3b","SHA256Sum":"32bd758f980c8f239163b8cf426a9211c90efe654c310bcb607c2e4a59b62d72","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2025.08.01","VibList":[{"Name":"storcli","Version":"007.3212.0000.0000-02"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Installing VIBs on the ESXi 9.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"},{"Lang":"ja","Value":"<p><strong>ESXiシェルからのESXi9.0ホストへのVIBのインストール：</strong></p><ul><li>ESXiホストのローカルパスへのVIBの転送</li><li>ESXiシェルで以下のesxcliコマンドを実行して、VIBをインストールします。</li><li><strong># esxcli software vib install -d <path><componet_bundle></strong><strong> </strong></li><li>署名なしバイナリの場合は、installコマンドで--no-sig-checkパラメーターを渡す必要があります</li><li><strong># esxcli software vib install -d <path><componet_bundle> --no-sig-check</strong></li></ul><p><strong>VIBパッケージは次のコマンドを使用して削除できます</strong></p><ul><li><strong># esxcli software vib remove -n <filename></strong></li><li>インストールされているvibファイル名をリストするには、<strong># esxcli software vib list | grep storcli</strong>コマンドを使用します</li></ul>"},{"Lang":"cn","Value":"<p><strong>Installing VIBs on the ESXi 9.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware9.0 (For Gen10P and Gen11  Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware 9.0 (For Gen10PおよびGen11コントローラー)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware9.0 (For Gen10P and Gen11  Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T04:15:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加<ul><li>コマンド: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.08.01"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加<ul><li>コマンド: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.08.01"}],"SWKeys":[{"Name":"BCM-storcli:007.3212.0000.0000-02","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3212.0000.0000-02","SWKeyExpectedPath":"software:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1f74b0db72fd44a2aff64ce6d90b2d4a"}]},{"ProductId":"896b673e61904db68a62db4c589536af","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for ML30 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SC_ML30GEN10Plus_ME_06.00.03.708.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2283838","DateModified":"2025-07-31T08:45:21","FileList":["payload.json","SC_ML30GEN10Plus_ME_06.00.03.708.signed.bin","SC_ML30GEN10Plus_ME_06.00.03.708.xml"],"MD5Sum":"adc77424b0ea5ce44cc36e48c771a45f","Name":"SC_ML30GEN10Plus_ME_06.00.03.708.fwpkg","Release":"2025-07-31T08:44:05","Revision":"","SHA1Sum":"b9caafeb1e4e137caa5e57af2c901ac72f0c56e1","SHA256Sum":"bf3126079ebeb146af199543ceb32b6d816b5dbd05f6a08851f881895bc2d58f","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェアfor HPE ProLiant ML30 Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-31T06:52:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.700 (2.30_01_07_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"06.00.03.708"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"d156e66d18654adcb7d16657128597b2"}]},{"ProductId":"fae7c963a551489594d913b81c29f2a4","Versions":[{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Power Management"},{"Lang":"ja","Value":"ファームウェア - パワー マネジメント"},{"Lang":"cn","Value":"固件 - 电源管理"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"150919","DateModified":"2024-08-21T05:17:20","FileList":["payload.json","PICGen10-1.1.4-1.xml","PICGen10_v1.1.4_hdr.signed.hex"],"MD5Sum":"72db6077bfaa2f75f2a81ea7b943e554","Name":"PICGen10-1.1.4-1.fwpkg","Release":"2024-08-21T05:13:02","Revision":"B","SHA1Sum":"903f3790b3a941f18adc03dad7ef78e5e7e56999","SHA256Sum":"631ef83cfa8ff875fa67ad904dadf0750d46dcf885c52143bb677db36e86db7e","Size":"147KB","TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM,&nbsp;which is found on the <strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong> (SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the <strong><u>USB Key Creator Utility</u></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<u><a href=\"http://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a></u>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong>（SPP）ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><u>USB Key Creator Utility</u></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM,&nbsp;which is found on the <strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong> (SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the <strong><u>USB Key Creator Utility</u></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-09-21T03:24:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"}],"SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"84e80a3fb2e04c93b20e3b09f3a5d3c5"}]},{"ProductId":"00184010ed0a41829836f7c60269273f","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8002-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8002"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1908-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1908"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1908-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Windows Operating Systems."},{"Lang":"ja","Value":"このパッケージは、Windowsオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"}],"Files":[{"Bytes":"27502528","DateModified":"2025-12-01T09:59:14","FileList":["cp069155.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1908-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1908-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_35_8002-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"5265cdd863fda552789d50c91f963647","Name":"cp069155.exe","Release":"2025-12-01T09:55:56","Revision":"","SHA1Sum":"007284f706b08f85a1e564ac618f66d5cb2f9c38","SHA256Sum":"86cc962919448f46b58bbc8b1869429ea234ed9471e83da8fbdd66013e3da6e1","Size":"26MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.0.24"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p> From that drive and directory, execute the downloaded file.</p><p> Click the Install button to proceed with the installation.</p>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p> そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> インストールボタンをクリックして、インストールを開始してください。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox Ethernet only adapters"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(Windows x64) for HPE Mellanox Ethernetアダプター専用"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T10:49:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2ポート640FLR-SFP28アダプター)</li><li>817753-B21 (HPE Ethernet 25Gb 2ポート640SFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>874253-B21（HPE Ethernet 100Gb 1ポート842QSFP28アダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4506で修正されました：</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.0.23"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1908にアップデートされました。</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2ポート640FLR-SFP28アダプター)</li><li>817753-B21 (HPE Ethernet 25Gb 2ポート640SFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.8002にアップデートされました。</strong></p><ul><li>874253-B21（HPE Ethernet 100Gb 1ポート842QSFP28アダプター）</li></ul><p><strong>バージョン14.32.1908には、以下の新機能と変更が含まれます。</strong></p><ul><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。</li></ul><p><strong>バージョン16.35.8002には、以下の新機能と変更が含まれます。</strong></p><ul><li>ファームウェア例外パス処理のパフォーマンスが向上し、構成されたSR-IOVインスタンスの数の増加をより適切にサポートできるようになりました。</li><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。</li></ul>","Fixes":"<p><strong>バージョン14.32.1908には修正は含まれていません。</strong></p><p><strong>以下の問題点がバージョン16.35.8002で修正されました。</strong></p><ul><li>FWがCQ回復モードに入った後、ファームウェアはPFの正しいCQをスキャンできませんでした。その結果、PFのCQが回復されませんでした。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.0.24"}],"SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"a5c5e6adb1ae4f7d998b40a262eea4a0"}]},{"ProductId":"eeaaff922a754e178b46a3315fd0a64a","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_OCP3_9p55_CFGID7p2_K97342_8000FDFD.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3863.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_9p55_CFGID7p2_K97470_8000FE06.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3863.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3863.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3863.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3863.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3863.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するIntel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel Ethernet NICs ROM images running under Linux x86_64 platform."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th><strong>Single&nbsp;</strong>NVM Version</th><th><strong>FW Version</strong></th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter</td><td>8000FB4C</td><td>1.3815.0</td><td>N/A</td><td>9.54</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter</td><td>8000FB53</td><td>1.3815.0</td><td>N/A</td><td>9.54</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter</td><td>8000123F</td><td>1.3815.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3&nbsp;Adapter</td><td>80001234</td><td>1.3815.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (2-port)</td><td>8000119C</td><td>1.3815.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (4-port)</td><td>8000119D</td><td>1.3815.0</td><td>N/A</td><td>N/A</td></tr></tbody></table><p>The combo image v1.3815.0&nbsp;includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.59, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.86, 10GbE - v8.2.91, 40GbE - v5.0.20</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVMバージョン</th><th>OROMバージョン</th><th>シングルNVMバージョン</th><th><strong>FWバージョン</strong></th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2ポートSFP+ OCP3 X710-DA2アダプター</td><td>8000FB4C</td><td>1.3815.0</td><td>N/A</td><td>9.54</td></tr><tr><td>HPE Ethernet 10Gb 2ポートSFP+ X710-DA2アダプター</td><td>8000FB53</td><td>1.3815.0</td><td>N/A</td><td>9.54</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4ポートBASE-Tアダプター</td><td>8000123F</td><td>1.3815.0</td><td>N/A</td><td>N/A    </td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4ポートBASE-T OCP3アダプター</td><td>80001234</td><td>1.3815.0</td><td>N/A</td><td>N/A    </td></tr><tr><td>Intel (R) I350 Gigabit Network Connection (2ポート)</td><td>8000119C</td><td>1.3815.0</td><td>N/A</td><td>N/A    </td></tr><tr><td>Intel (R) I350 Gigabit Network Connection(4ポート)</td><td>8000119D</td><td>1.3815.0</td><td>N/A</td><td>N/A</td></tr></tbody></table><p>コンボイメージ v1.3815.0 には以下が含まれます。 Boot Agent: 1GbE - v1.5.90、10GbE - v2.4.59、40GbE - v1.1.45& UEFIドライバー: 1GbE - v9.8.86、10GbE - v8.2.91、40GbE - v5.0.20</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th><strong>Single&nbsp;</strong>NVM Version</th><th><strong>FW Version</strong></th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter</td><td>8000FB4C</td><td>1.3815.0</td><td>N/A</td><td>9.54</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter</td><td>8000FB53</td><td>1.3815.0</td><td>N/A</td><td>9.54</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter</td><td>8000123F</td><td>1.3815.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3&nbsp;Adapter</td><td>80001234</td><td>1.3815.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (2-port)</td><td>8000119C</td><td>1.3815.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (4-port)</td><td>8000119D</td><td>1.3815.0</td><td>N/A</td><td>N/A</td></tr></tbody></table><p>The combo image v1.3815.0&nbsp;includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.59, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.86, 10GbE - v8.2.91, 40GbE - v5.0.20</p>"}],"Files":[{"Bytes":"4726744","DateModified":"2025-09-15T22:05:57","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/CP068728.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/CP068728.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/BootIMG_ISA.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP_ISA.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000119C.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000119C.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000119D.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000119D.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_X710DA2_9p55_CFGID7p2_K97470_8000FE06.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_X710DA2_OCP3_9p55_CFGID7p2_K97342_8000FDFD.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_X710_DA_OCP3_EEPROM_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_i350T4_K68277_8000123F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_i350T4_K68277_8000123F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001234.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001234.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.35.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068728.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068728.scexe"],"MD5Sum":"9b99e1628e76fdb86c24ad2a87c522cc","Name":"firmware-nic-is-intel-1.35.0-1.1.x86_64.rpm","Release":"2025-09-16T02:54:50","Revision":"","SHA1Sum":"7ac40f84e9b37b3ae4b0d787584948f27ad109f6","SHA256Sum":"681cc0f8cf0fd96dbb5eb5b6aa902020e2d014606eaca993874d4617280131b7","Size":"4MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"1.35.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":3600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca93656a5","SWKey":"kmod-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec805649d9","SWKey":"kmod-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","SWKey":"i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Intel-i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above.</li><br />&nbsp;</ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"},{"Lang":"ja","Value":"<p><em><strong><em><strong><em><strong><em><strong>rpmインストールによるファームウェアのアップデート：</strong></em></strong></em></strong></em></strong></em></p><ul><li>次のコマンドを使用して、NICファームウェアをインストールします：  <em>rpm -ivh <rpm_filename>.rpm.  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><br /><li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。詳細については、'firmware-nic-*'フォルダーのCPxxxxxx.txtファイルを参照してください。firmware-nic-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。</li><br /><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します：<ul><li><em>./</em>CPxxxxxx<em>.scexe</em>（'/usr/lib/x86_64-linux-gnu'内）（または）</li><li>firmware-nic-*ロケーションの<em>./setup</em></li></ul></li><br /><li>rpmをアンインストールするには、次のコマンドを実行します：<em>rpm -e <rpm_package_name></em></li></ul><p><br /><em><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></em></p><ul><li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><br /><li>usr/lib/x86_64-linux-gnu/firmware-nic-*ロケーションに移動し、<em>./hpsetup</em>を実行してファームウェアをアップデートします。firmware-nic-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><br /> </ul><p><em><strong>追加情報：</strong></em></p><ul><li>特定のシナリオでは、EPROMをアップデートした後にシステムを再起動して、アダプターのフラッシュROM（OROM）をアップデートするためにコンポーネントの再実行を要求されることがあります。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるCPxxxxxx.logファイルに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアrpmパッケージのインストール（rpm -ivh）は、アダプターのファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。アダプターのファームウェアをアップデートするには、上記の手順に従う必要があります。 </li><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。ダウングレードに関する制限について詳しくは、カスタマーアドバイザリhttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171ja_jpを参照してください。</li></ul><p> </p><p><em><strong>ドライバー依存関係：</strong></em></p><p>この製品は、システム内に存在するすべてのIntel NICデバイスをスキャンします。システムに複数のIntel E810/X710/I350/X550ネットワークアダプターが存在する場合、一部のカーネルでは、対応するインボックスNICドライバーがこの製品のファームウェアライブラリで正常に動作しない可能性があります。この製品でエラーが発生した場合は、どのIntelデバイスのファームウェアをアップグレードしようとしているかに関係なく、システム上のすべてのIntel NICデバイスに対してIntel OOB NICドライバー (igb/ixgbe/i40e/ice) をインストールする必要があります。</p>"},{"Lang":"cn","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above.</li><br />&nbsp;</ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Intel Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"Intelオンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"Intel Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T03:04:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product removes RDE AutoSpeedNegotiationEnabled property.</li><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product removes RDE AutoSpeedNegotiationEnabled property.</li><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product removes RDE AutoSpeedNegotiationEnabled property.</li><li>This product fixes an issue where the FW upgrade failed with 562SFP+/x710 adapters due to timeout.</li><li>This product fixes an issue where the port 2 and port 3 do not always report link down when link is down on 4-Port Ethernet Adapter.</li></ul>","Lang":"cn"}],"Version":"1.34.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"1.35.0"}],"SWKeys":[{"Name":"IS_INTEL","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bd855fecb9b04c308ad614f4087e8ccc"}]},{"ProductId":"2180429b88ed4e24883a75dbd70724b0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-i40e-2.23.17-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-i40e) to (i40e). Now we revert this change from (i40e) to (<strong>hp</strong>-i40e).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-i40e and kmod-i40e are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-i40e-2.23.17-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-i40e and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-i40e-2.23.17-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-i40e）から（i40e）に変更されました。この変更を（i40e）から（<strong>hp</strong>-i40e）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-i40eとkmod-i40eはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-i40e-2.23.17-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-i40eによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-i40e-2.23.17-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-i40e) to (i40e). Now we revert this change from (i40e) to (<strong>hp</strong>-i40e).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-i40e and kmod-i40e are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-i40e-2.23.17-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-i40e and then install the updated RPM.</p>"}],"Files":[{"Bytes":"425192","DateModified":"2025-09-15T15:46:12","FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-i40e","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/39","./usr/lib/.build-id/39/663372ee368aa3ba74c179c69ce75ed9478beb","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"MD5Sum":"8aca63c760730d2c910a1d6ed08ea7fc","Name":"kmod-hp-i40e-2.28.10-1.rhel9u5.x86_64.rpm","Release":"2025-09-15T15:40:04","Revision":"","SHA1Sum":"9824413e93f4ed942c2ce142bba07f77ce4fea57","SHA256Sum":"eebce2eb3a7cedb2a5ad21eb20e398fca4573edcc6428683c98c3118ea3bfbd2","Size":"415KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"TypeOfChange":"1","Version":"2.28.10-1"},{"Bytes":"425289","DateModified":"2025-09-15T15:50:27","FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-i40e","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/b7","./usr/lib/.build-id/b7/58136c5c6e021d6458c222980cdfc7fe0ef056","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"MD5Sum":"ac4cef5bc47b2c6086fa672d77cec627","Name":"kmod-hp-i40e-2.28.10-1.rhel9u6.x86_64.rpm","Release":"2025-09-15T15:40:04","Revision":"","SHA1Sum":"cbc4b303ad1e6989a6ecb04907bde1a6a6b29be4","SHA256Sum":"8a968d55e029404d56b2c075333207e43f1d98e4d1c309576f8c81db6e36d6bd","Size":"415KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"TypeOfChange":"1","Version":"2.28.10-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel i40eドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T01:42:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.6.</p>","Fixes":"<p>This product fixes an issue where the VF can abuse of PF-VF Capability Exchange commands to enable/disable features and mess with state dependent command.</p>","Lang":"en"},{"Enhancements":"<p>この製品は、現在Red Hat Enterprise Linux 9.6をサポートします。</p>","Fixes":"<p>この製品は、VFがPF-VF Capability Exchange コマンドを悪用して機能を有効化/無効化したり、状態依存のコマンドを混乱させたりする可能性がある問題を修正します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.6.</p>","Fixes":"<p>This product fixes an issue where the VF can abuse of PF-VF Capability Exchange commands to enable/disable features and mess with state dependent command.</p>","Lang":"cn"}],"Version":"2.28.7-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.28.10-1"}],"SWKeys":[{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"66b394f115194b128548cc807ba42ca3"}]},{"ProductId":"39cff1d9c55641a8a5495e9c755fc456","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30505a575346","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30505a575348","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-30505a57534b","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-30505a584641","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MO001600PZWSH、MO003200PZWSK、MO000800PZWSF、およびMO006400PZXFA"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>.</li></ul><p><strong>Known Issues:</strong></p><ul><li>FW cannot downgrade to HPD2.</li></ul>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付:</strong><br />     HPD4<br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPD3<br /><strong>以前のファームウェアバージョン：</strong><br />     HPD3<br /><strong>機能強化/新しい機能：</strong><br />     なし<br /><strong>修正された問題点：</strong></p><ul><li>これはファームウェアメンテナンスリリースです。その他のバグ修正と改善とともに、潜在的なデータロスの問題に対処します。</li><li>詳しくは、HPE顧客向け報告：<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>を参照してください。</li></ul><p><strong>既知の問題点：</strong></p><ul><li>FWはHPD2にダウングレードできません。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>.</li></ul><p><strong>Known Issues:</strong></p><ul><li>FW cannot downgrade to HPD2.</li></ul>"}],"Files":[{"Bytes":"1993408","DateModified":"2025-07-15T09:28:22","FileList":["payload.json","Samsung_PM165X_GPM1655SAMD4.HPb","Samsung_PM165X_GPM1655SAMD4.xml"],"MD5Sum":"e5f47f66d6827cb7f8462a08c9ce0499","Name":"Samsung_PM165X_GPM1655SAMD4.fwpkg","Release":"2025-08-14T00:00:00","Revision":"","SHA1Sum":"c29ac81ebe8e58e92c15654a2ad07d3de9c3690a","SHA256Sum":"583892a4172e615263221d2e5289328774780173b10f3da89b193a8718a71f08","Size":"1MB","TargetGUIDs":["4d2340a5-304f-3030-3830-30505a575346","4d2340a5-304f-3130-3630-30505a575348","4d2340a5-304f-3330-3230-30505a57534b","4d2340a5-304f-3630-3430-30505a584641"],"TypeOfChange":"2","Version":"HPD4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\" id=\"menurdf7\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\"> https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/</a> to search and download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager (SUM) を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 <a href=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\" id=\"menurdf7\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\">https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/</a>を参照して、iLOrestツールの最新バージョンを検索してダウンロードしてください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\" id=\"menurdf7\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/\"> https://servermanagementportal.ext.hpe.com/docs/redfishclients/ilorest-userguide/</a> to search and download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO001600PZWSH、MO003200PZWSK、MO000800PZWSF、およびMO006400PZXFA"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO001600PZWSH","TargetGUID":"4d2340a5-304f-3130-3630-30505a575348","Type":"sas"},{"Id":"MO003200PZWSK","TargetGUID":"4d2340a5-304f-3330-3230-30505a57534b","Type":"sas"},{"Id":"MO000800PZWSF","TargetGUID":"4d2340a5-304f-3030-3830-30505a575346","Type":"sas"},{"Id":"MO006400PZXFA","TargetGUID":"4d2340a5-304f-3630-3430-30505a584641","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-21T07:07:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>&nbsp;which will be active on 18-Aug-2025.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>これはファームウェアメンテナンスリリースです。その他のバグ修正と改善とともに、潜在的なデータロスの問題に対処します。</li><li>詳しくは、HPE顧客向け報告：<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a> (2025年8月18日から有効) を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>&nbsp;which will be active on 18-Aug-2025.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>これはファームウェアメンテナンスリリースです。その他のバグ修正と改善とともに、潜在的なデータロスの問題に対処します。</li><li>詳しくは、HPE顧客向け報告：<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a firmware maintenance release. It addresses a potential data loss issue, along with other bug fixes and improvements.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00150711en_us</a>.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000800PZWSF","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001600PZWSH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003200PZWSK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO006400PZXFA","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Critical"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"d756031e46334c08a77fc0049d523b08"}]},{"ProductId":"bca5397d7ba147ddbb0eb4fee4d4d567","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.09"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.09"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.09"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021109.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.09"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターのファームウェアをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4280007","DateModified":"2025-11-26T22:16:16","FileList":["./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/CP068326.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/bk020501.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/create_conf_file.sh","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/libHBAAPI.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/libHBAAPI.so.2","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/libqlcoutil.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/libqlsdm.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/mh021109.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/qlafwupdate.sub","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/remove_conf_file.sh","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.11.01-1.3/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068326.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068326.scexe"],"MD5Sum":"f30fd4f9ae7f01cb00ad757bf879d50d","Name":"firmware-fc-qlogic-2025.11.01-1.3.x86_64.rpm","Release":"2025-11-27T04:01:32","Revision":"","SHA1Sum":"9c70cb7fb346cb84fa0d1b7a2a7404d6c825a6c9","SHA256Sum":"64414734e474d60a2531c7a60b1aac750ef262153a984ddfa05b3a3019f93a3c","Size":"4MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2025.11.01"}],"Installation":{"Command":"installer","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Action prior to the installation/upgrade of qlafwupdate on RHEL 10.x</strong></p><p>qlafwupdate utility depends on libcrypt.so.1 library. This library is not installed by default on RHEL 10.x. Please install libxcrypt-compat RPM to install libcrypt.so.1 library before using qlafwupdate utility.</p><p>&nbsp;</p><p>&nbsp;</p><p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />&nbsp;<br />1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;in an firmware-* folder.<br />&nbsp;<br />2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />&nbsp;<br />When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command.</p><p>NOTE: During the flash operation, the message &quot;No Adapter Found!&quot; may appear in the logs. These messages do not indicate a problem with the firmware flash operation and may be ignored.</p><p>&nbsp;</p><ul><li><p>It is advised to provide read-write permissions on /var/tmp folder. Firmware deployment via Service Pack for ProLiant(SPP) might be unsuccessful in some cases , if read-write(rw) permissions are not enable on /tmp or /var/tmp directories.</p></li></ul>"},{"Lang":"ja","Value":"<p><strong>RHEL 10.xでのqlafwupdateのインストール/アップグレード前のアクション</strong></p><p>qlafwupdateユーティリティはlibcrypt.so.1ライブラリに依存します。このライブラリはRHEL 10.xではデフォルトでインストールされません。qlafwupdateユーティリティを使用する前に、libxcrypt-compat RPMをインストールしてlibcrypt.so.1ライブラリをインストールしてください。</p><p> </p><p> </p><p>ファームウェアインストールは、2段階のプロセスです。  ファームウェアインストールツールrpmをインストールし、ファームウェアをアップデートするため、インストールしたツールを実行します。<br /> <br />1. ファームウェアインストレーションツール：rpm -Uvh <rpm_package_name>.rpmをインストールします。これにより、ファームウェアインストレーションツールがfirmware-*フォルダーの/usr/lib/x86_64-linux-gnuに抽出されます (64ビットシステム) 。<br /> <br />2. 使用するシステムの適切な場所へcdし、./setupを実行してファームウェアをアップデートします<br /> <br />ファームウェアインストレーションの完了後は、rpm -eコマンドを使用して、システムからファームウェアインストレーションツールを削除してもかまいません。</p><p>注記：フラッシュ操作中に\"No Adapter Found!\"というメッセージが ログに記録されることがあります。これらのメッセージは、ファームウェアフラッシュ操作の問題を示していないため、無視してかまいません。</p><p> </p><ul><li><p>/var/tmpフォルダーに読み取り/書き込み権限を付与することをお勧めします。/tmpまたは/var/tmpディレクトリで読み取り/書き込み(rw)権限が有効になっていない場合、Service Pack for ProLiant (SPP) を介したファームウェアの展開が失敗する場合があります。</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Linux (x86_64)"},{"Lang":"ja","Value":"QLogicファイバーチャネルホストバスアダプター用HPEファームウェアフラッシュ - Linux (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T07:07:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"<p>Fixed the following:</p><ol><li>Windows BitLocker causes the system boot due to ROM signature failure during POST.</li><li>Increase an internal timeout value for SPI/Flash read.</li></ol>","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">アダプター</p></td><td><p dir=\"LTR\">速度</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">ファームウェア</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">ブートBIOS</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBデュアルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBシングルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">2.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"<p>以下を修正しました。</p><ol><li>Windows BitLockerにより、POST中にROM署名エラーが発生し、システムが起動します。</li><li>SPI/フラッシュ読み取りの内部タイムアウト値を増やします。</li></ol>","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"<p>Fixed the following:</p><ol><li>Windows BitLocker causes the system boot due to ROM signature failure during POST.</li><li>Increase an internal timeout value for SPI/Flash read.</li></ol>","Lang":"cn"}],"Version":"2025.05.02"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.09</p></td><td><p dir=\"LTR\">09.15.15</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.09</td><td>09.15.15</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.11.01"}],"SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"29029345aa4a420b9a48b15170e5cfb2"}]},{"ProductId":"75d8486987f7480b8e2a0459e1d59d0e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、MB018000GYDKR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4039976","DateModified":"2025-11-14T13:54:15","FileList":["cp068737.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVSBPTG3.rel"],"MD5Sum":"4a26777375d0a0991869a8a9c0bbb3a9","Name":"cp068737.exe","Release":"2025-11-14T13:49:07","Revision":"B","SHA1Sum":"ff9b3c91bffeea49c49a11857818809d16c7fa82","SHA256Sum":"bbef212dd316bbbfbec78b4e3050578a11ed5c572df48e9b950684c040875edb","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、およびMB018000GYDKRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB010000GYDKP","TargetGUID":"4d2340a5-3042-3031-3030-304759444b50","Type":"sata"},{"Id":"MB016000GYDKQ","TargetGUID":"4d2340a5-3042-3631-3030-304759444b51","Type":"sata"},{"Id":"MB018000GYDKR","TargetGUID":"4d2340a5-3042-3831-3030-304759444b52","Type":"sata"},{"Id":"MB012000GYCJL","TargetGUID":"4d2340a5-3042-3231-3030-304759434a4c","Type":"sata"},{"Id":"MB014000GYCJT","TargetGUID":"4d2340a5-3042-3431-3030-304759434a54","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T05:38:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cd123e76da4e4e189a0aa46bfb55d4f0"}]},{"ProductId":"eab35afbdd7e439ba338f8fae23de885","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0.</li></ul>"}],"Files":[{"Bytes":"7660468","DateModified":"2025-07-31T11:55:00","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-1.1/CP067324.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-1.1/K511HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067324.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067324.scexe"],"MD5Sum":"40ab1bea4fcce5217e9e4ed91ec213e0","Name":"firmware-hdd-befd42bd64_0HPG3-1.1_amd64.deb","Release":"2025-07-31T16:48:55","Revision":"","SHA1Sum":"23c17dde67449bbacf1224e0307a7c63b61de407","SHA256Sum":"fd8e73dbc81ae4cdcb8717bb0a50c44a184ce078db8978e06662f84268e9437e","Size":"7MB","TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP043255.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK000480GZCNE","TargetGUID":"562340a5-304b-3030-3438-30475a434e45","Type":"sata"},{"Id":"VK000960GZCNF","TargetGUID":"562340a5-304b-3030-3936-30475a434e46","Type":"sata"},{"Id":"VK001920GZCNH","TargetGUID":"562340a5-304b-3130-3932-30475a434e48","Type":"sata"},{"Id":"VK003840GZCNK","TargetGUID":"562340a5-304b-3330-3834-30475a434e4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:24:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improve the FW about data mismatch after SPL</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Improve the FW about data mismatch after SPL</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improve the FW about data mismatch after SPL</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4e2e15fd80234cffa9f6e16addcddb00"}]},{"ProductId":"1e10e20d274448bb9d2d1625880b482d","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.27"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, NCSI, iSCSI, FCoE and CCM code running under Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このパッケージには、Microsoft Windows Server 2022およびWindows Server 2025で動作するHPE ProLiant QLogic NX2 Gigabit Ethernet NICブートコード、PXE、NCSI、iSCSI、FCoEおよびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4115520","DateModified":"2025-11-14T06:59:15","FileList":["cp069565.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.19.27.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"34f0c85cf9096b8340cd0f0c0688d9ad","Name":"cp069565.exe","Release":"2025-11-14T06:50:41","Revision":"C","SHA1Sum":"697669b3a73bd04ca9eae8b5ca685be36cb9b126","SHA256Sum":"494bc5708fc74d78f2fac5a4c013b71d9005b5d856e3f3d1fe16fde9cda99db5","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"5.3.9.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","SWKey":"evbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.13.165.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>［インストール］ボタンをクリックして、インストールを開始します。</p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T09:16:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"5.3.9.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Local 24H2 をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"cn"}],"Version":"5.3.9.0"}],"SWKeys":[{"Name":"QlNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"f97be98cdd384e279b5474536eba0080"}]},{"ProductId":"134da74460bf4b5aa8511e630ba5a272","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"MicroserverGen10PlusSPS_05.01.05.103.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8409129","DateModified":"2025-07-29T11:39:19","FileList":["MicroserverGen10PlusSPS_05.01.05.103.signed.bin","MicroserverGen10PlusSPS_05.01.05.103.xml","payload.json"],"MD5Sum":"7d0f2548be83e9493c863e3b91345146","Name":"MicroserverGen10PlusSPS_05.01.05.103.fwpkg","Release":"2025-07-29T11:36:35","Revision":"","SHA1Sum":"f08918030863b2a715d6cc80440a8f20751c4c7c","SHA256Sum":"2d074d75d531781f5c924a52b85b56f802b197ec3fe30656fce0fbbf2b7a640d","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE MicroServer Gen10 Plus"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE MicroServer Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-24T02:22:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 05.01.05.005は、システムROM 3.50 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"05.01.05.103"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"d5cc2651bb61477f84c5a08abe244b8a"}]},{"ProductId":"509f54411aaa488d8ade3254836debf4","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b58565948","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58565a44","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58565a45","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b58565946","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b58565a41","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b58565a42","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3531-3336-304b58565a43","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルにファームウェアを提供します：MO001600KXVYH、MO003200KXVZD、MO006400KXVZE、VO001920KXVYF、VO003840KXVZA、VO007680KXVZBおよびVO015360KXVZC"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2386805","DateModified":"2025-07-03T16:07:17","FileList":["Kioxia_CM7_KACM7ALSHPK4.HPb","Kioxia_CM7_KACM7ALSHPK4.xml","payload.json"],"MD5Sum":"70616551a8a4315f5f77cd3039b4b82b","Name":"Kioxia_CM7_KACM7ALSHPK4.fwpkg","Release":"2025-07-03T16:04:30","Revision":"","SHA1Sum":"a1992396bc7f3ca5335b7c4d42d1b4a539a7d68f","SHA256Sum":"f6e47615b74a8caa93eb06f71dbbcc31855fca777bb2113b3bb95f91ffc03110","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3130-3630-304b58565948","4d2340a5-304f-3330-3230-304b58565a44","4d2340a5-304f-3630-3430-304b58565a45","562340a5-304f-3130-3932-304b58565946","562340a5-304f-3330-3834-304b58565a41","562340a5-304f-3730-3638-304b58565a42","562340a5-304f-3531-3336-304b58565a43"],"TypeOfChange":"1","Version":"HPK4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"},{"Lang":"ja","Value":"ドライブ用ユニバーサルファームウェアパッケージ - MO001600KXVYH、MO003200KXVZD、MO006400KXVZE、VO001920KXVYF、VO003840KXVZA、VO007680KXVZBおよびVO015360KXVZC"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO001600KXVYH","TargetGUID":"4d2340a5-304f-3130-3630-304b58565948","Type":"nvme"},{"Id":"MO003200KXVZD","TargetGUID":"4d2340a5-304f-3330-3230-304b58565a44","Type":"nvme"},{"Id":"MO006400KXVZE","TargetGUID":"4d2340a5-304f-3630-3430-304b58565a45","Type":"nvme"},{"Id":"VO001920KXVYF","TargetGUID":"562340a5-304f-3130-3932-304b58565946","Type":"nvme"},{"Id":"VO003840KXVZA","TargetGUID":"562340a5-304f-3330-3834-304b58565a41","Type":"nvme"},{"Id":"VO007680KXVZB","TargetGUID":"562340a5-304f-3730-3638-304b58565a42","Type":"nvme"},{"Id":"VO015360KXVZC","TargetGUID":"562340a5-304f-3531-3336-304b58565a43","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-02T07:42:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for PCIe link length drop in AMD x2 system configuration</li><li>Fix for drive detection after hot re-insert on Windows</li><li>Fix for other regular FW patch release</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>AMD x2システム構成でのPCIeリンク長の低下の修正</li><li>Windowsでのホット再挿入後のドライブ検出の修正</li><li>その他の定期的なFWパッチリリースの修正</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for PCIe link length drop in AMD x2 system configuration</li><li>Fix for drive detection after hot re-insert on Windows</li><li>Fix for other regular FW patch release</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Regular FW maintenance release for sanitize, DRAM and log page fix.</li></ul>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"MO001600KXVYH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXVZD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXVZE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXVYF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXVZA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXVZB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KXVZC","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"5c536fa4fdef41e08d38b08ff10d54da"}]},{"ProductId":"884d4de7b5b3447098d2f7fe88975145","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li><li>Assert fixes, logging enhancements and all current firmware improvements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li><li>Assert fixes, logging enhancements and all current firmware improvements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4324716","DateModified":"2025-08-02T20:49:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-1.1/CP067359.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-1.1/SHPEEVSBPTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067359.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067359.scexe"],"MD5Sum":"3f5f695f9c79df00b22993e5ee677c09","Name":"firmware-hdd-4fbb6d96e5_0HPG3-1.1_amd64.deb","Release":"2025-08-03T01:42:28","Revision":"","SHA1Sum":"2ff82ddf57e43d9ecc5aaa816c643358c207adf8","SHA256Sum":"f7e07f91448ea857c7f2ecc694f384b593daf99a08750a61fad7451ecd7c80d1","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000GYDKP","TargetGUID":"4d2340a5-3042-3031-3030-304759444b50","Type":"sata"},{"Id":"MB016000GYDKQ","TargetGUID":"4d2340a5-3042-3631-3030-304759444b51","Type":"sata"},{"Id":"MB018000GYDKR","TargetGUID":"4d2340a5-3042-3831-3030-304759444b52","Type":"sata"},{"Id":"MB012000GYCJL","TargetGUID":"4d2340a5-3042-3231-3030-304759434a4c","Type":"sata"},{"Id":"MB014000GYCJT","TargetGUID":"4d2340a5-3042-3431-3030-304759434a54","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:55:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Regular Firmware changes included:</p><ul><li>&nbsp;&nbsp;&nbsp; corner case performance enhance.</li><li>&nbsp;&nbsp;&nbsp; Servo change that resolves issue with early heat application from Idle sweep seek terminated that may cause read errors.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"398c6edc1426486c8084f3374a04dbcf"}]},{"ProductId":"cfa8fbdb2f4a4c81b7b1ee3f89f284e0","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U30_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11858160","DateModified":"2026-01-14T06:32:22","FileList":["cp070208.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U30_3.62_01_09_2026.signed.flash"],"MD5Sum":"93150e26b889eabc980446b420a7c3be","Name":"cp070208.exe","Release":"2026-01-14T06:29:56","Revision":"","SHA1Sum":"46d1c5c8b7b11a4ec13854c3423a5ab778d64fce","SHA256Sum":"f80a37a4e5294fb99110c6692e7b1691d2152e45402a0d88996f4df640cf5036","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL380 Gen10 (U30)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-11T14:09:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"d181122a10ec43c3b9f0517f12b32a1e"}]},{"ProductId":"d287970503c042a480f1860ec2c054c7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB016000JXLBAおよびMB018000JXLAU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"7205518","DateModified":"2025-09-17T12:13:28","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/CP068850.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/PCHFA2B3.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068850.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068850.scexe"],"MD5Sum":"2bff0b454d62c070f3e785cb48c6d17f","Name":"firmware-hdd-d550523365-HPD3-6.1.x86_64.rpm","Release":"2025-09-17T17:03:05","Revision":"F","SHA1Sum":"0cdddbd0447af5b7367cbfc8e447e4a7c096767a","SHA256Sum":"9015b33f9db4806ea4ad0ad594d36aaf326891015f73f23a8668d2d4d4b1d19b","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB016000JXLBAおよびMB018000JXLAUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB016000JXLBA","TargetGUID":"4d2340a5-3042-3631-3030-304a584c4241","Type":"sas"},{"Id":"MB018000JXLAU","TargetGUID":"4d2340a5-3042-3831-3030-304a584c4155","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:19:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RHEL 10のサポートを追加しました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cd1b23f75c144dcbb22cd0a6a6da4805"}]},{"ProductId":"ab42380273374a988dbcb1a25432ed96","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8002-MCX653106A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900345","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージfor HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 PCIe4 x16 MCX653106A-HDATアダプター: HPE部品番号P31324-B21およびP31324-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p style=\"margin-left:40px\"><strong>HDR / 200GbEケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR対NDRスイッチ相互運用ケーブル：</strong></p><ul><li>HDR    P45733-B21    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10mスプリッターアクティブ光ケーブル</li><li>HDR    P45733-B22    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30mスプリッターアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6276637","DateModified":"2025-10-08T11:47:16","FileList":["20_43_8002-MCX653106A-HDA_HPE_Ax.pldm.signed","20_43_8002-MCX653106A-HDA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"e2b6bbbe3e146ac5c8e09ca916e3054c","Name":"20_43_8002-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","Release":"2025-10-08T11:45:07","Revision":"","SHA1Sum":"010e6538a88c096872b9932ba2dc548a84e3473b","SHA256Sum":"87e8c2c1f5a0bb9f09488c74056115cb95f1e6c167889a94d0627dcced04bd3c","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900345"],"TypeOfChange":"1","Version":"20.43.8002"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ（FWPKG）for HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 PCIe4 x16 MCX653106A-HDATアダプター: HPE部品番号P31324-B21およびP31324-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-08T11:28:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version&nbsp;20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"20.43.8002"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653106A-HDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"168297d168de4cf58c0363f57b697c72"}]},{"ProductId":"f8437d6127664644832d2cd688d58903","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A40_3.70_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.70 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"18219256","DateModified":"2026-01-14T07:50:09","FileList":["A40_3.70_01_09_2026.signed.flash","cp070203.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"d287ff987620d78a9c3c4721c6b890d4","Name":"cp070203.exe","Release":"2026-01-14T07:47:44","Revision":"","SHA1Sum":"fa3ace6c7f949948991ad709616b8d121d2d5bfe","SHA256Sum":"52fc8b2a2e55b2be9008cb38d924d0fbd9bb3c21eff6de4ad076348b6305a40d","Size":"17MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"1","Version":"3.70_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL385 Gen10 (A40) Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL385 Gen10 (A40) サーバー "},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL385 Gen10 (A40) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T10:42:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>CVE-2025-3052を軽減するために、デフォルトのセキュアブートDBXをアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。システムROMのこのリビジョンには、AMD第1世代EPYCプロセッサー用のAMDリファレンスコードNaplesPI 1.0.0.Rが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Redfish経由でのBIOS設定の変更が、同じ起動中にBIOSアップデートが実行された場合に、失敗するという問題に対処しました。</p><p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_09-05-2025"},{"ReleaseNotes":[{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.70_01-09-2026"}],"SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"3b83ac45ab8c4e908ea25b4c5baa283a"}]},{"ProductId":"594618f566cc4fbca055e8866278e53d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."},{"Lang":"cn","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."},{"Lang":"ja","Value":"Smart Storage Administrator（SSA）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるWebベースのアプリケーションです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[{"Lang":"en","Value":"<p>Users will automatically be logged out after a predetermined period of inactivity when using&nbsp;SSA&nbsp;and will have to re-login.</p><p>On the Web-based Management Device Homepage, under &quot;options&quot;, &quot;Anonymous Access&quot; should be enabled when using SSA.</p><p>When clicking on a controller that is currently being configured in a different&nbsp;SSA&nbsp;session, a message will appear which allows you to override the other&nbsp;SSA&nbsp;session or cancel. If you choose to override the other&nbsp;SSA&nbsp;session, any unsaved changes in the other session will be discarded.</p><p>To uninstall SSA, use Add/Remove Programs located in the Control Panel on Windows Systems.</p><p>To run&nbsp;SSA&nbsp;in local application mode on Windows, Internet Explorer must be the default browser.</p><p><strong>The following are known issues:</strong></p><ul><li>Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.</li></ul>"},{"Lang":"ja","Value":"<p>SSAを使用するとき、ユーザーは、定義されている期間使用していなかった場合、自動的にログアウトされ、再ログインが必要になります。</p><p>SSAを使用する場合、Webベースのマネジメントデバイスホームページ上で、\"オプション\"にある\"匿名アクセス\"を有効にする必要があります。</p><p>別のSSAセッション上の現在設定されているコントローラーをクリックすると、他のSSAセッションを上書きするかキャンセルするかのメッセージが表示されます。他のSSAセッションを上書きすると、他のセッションでの保存されていない変更は、廃棄されます。</p><p>SSAをアンインストールするには、Windowsのコントロールパネルのアプリケーションの追加と削除を使用します。</p><p>Windows上のローカルアプリケーションモードでSSAを動作させるには、Internet Explorerがデフォルトのブラウザーでなければなりません。</p><p><strong>既知の問題について</strong></p><ul><li>デバイスホームページのログインが初回時に動作しない場合があります。デバイスホームページリンクをクリックし、再度ログインしてください。</li></ul>"},{"Lang":"cn","Value":"<p>Users will automatically be logged out after a predetermined period of inactivity when using&nbsp;SSA&nbsp;and will have to re-login.</p><p>On the Web-based Management Device Homepage, under &quot;options&quot;, &quot;Anonymous Access&quot; should be enabled when using SSA.</p><p>When clicking on a controller that is currently being configured in a different&nbsp;SSA&nbsp;session, a message will appear which allows you to override the other&nbsp;SSA&nbsp;session or cancel. If you choose to override the other&nbsp;SSA&nbsp;session, any unsaved changes in the other session will be discarded.</p><p>To uninstall SSA, use Add/Remove Programs located in the Control Panel on Windows Systems.</p><p>To run&nbsp;SSA&nbsp;in local application mode on Windows, Internet Explorer must be the default browser.</p><p><strong>The following are known issues:</strong></p><ul><li>Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.</li></ul>"}],"Files":[{"Bytes":"10419216","DateModified":"2025-12-18T05:29:14","FileList":["cp069345.xml","cpqsetup.exe","cp_data.xml","genericmsi.dll","SSA66080_X64.msi"],"MD5Sum":"9b74fc1e0403f7dd77c2dfa054055433","Name":"cp069345.exe","Release":"2025-12-18T05:27:00","Revision":"","SHA1Sum":"13ff8881005c91a7e5163175887fbe2c45779cfd","SHA256Sum":"eeee874e530a029ad2fd7daacfd465941897640054e5cc354102bcaa002d33a5","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc02887d0"],"TypeOfChange":"1","Version":"6.60.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <P>From that drive and directory, execute the downloaded file. <P>Click the \"Install\" button to proceed with the installation. The utility will automatically be installed.</P>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<P>[インストール]ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</P>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <P>From that drive and directory, execute the downloaded file. <P>Click the \"Install\" button to proceed with the installation. The utility will automatically be installed.</P>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) for Windows 64ビット for Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:12:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix windows tool cert expire issue.</li></ul>","Lang":"cn"}],"Version":"6.50.13.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>RC drop 6.60.8.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RC drop 6.60.8.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>RC drop 6.60.8.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.60.8.0"}],"SWKeys":[{"Name":"ssa.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssa\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"505b38c67605470996f78145939919a0"}]},{"ProductId":"f4456005e9154f53969eae342b6e27c9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZ1LB3T8HMLA-00007","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"EDB7602Q.bin","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"EDB7602Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Disk"},{"Lang":"ja","Value":"ファームウェア - ストレージ ディスク"},{"Lang":"cn","Value":"固件 - 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MZ1LB3T8HMLA-00007 that can be installed directly on any HPE ProLiant m750 System running a supported Microsoft Windows Operating System installed in HPE Moonshot 1500 chassis."},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive model: MZ1LB3T8HMLA-00007 that can be installed directly on any HPE ProLiant m750 System running a supported Microsoft Windows Operating System installed in HPE Moonshot 1500 chassis."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7190400","DateModified":"2026-01-22T02:21:16","FileList":["cp070453.xml","cpqsetup.exe","EDB7602Q.bin","ilorest_chif.dll","payload.json"],"MD5Sum":"6a25b8b4d891a78fc5e22c1acb9527b5","Name":"cp070453.exe","Release":"2026-01-22T02:03:55","Revision":"B","SHA1Sum":"8746188910fb9f6c072e78b968ab90ebb2129a67","SHA256Sum":"6a619af1a8daec6baaa2472933927144869178c307f5ed542d444acad328e1d8","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"EDB7602Q"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Microsoft Windows - MZ1LB3T8HMLA-00007 Drive"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Microsoft Windows - MZ1LB3T8HMLA-00007ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"9000"},"SupportedDevices":[{"Id":"MZ1LB3T8HMLA-00007","TargetGUID":"4d2340a5-315a-424c-3354-384894df255d","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"Microsoft Windows 11","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-22T02:01:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"EDB7602Q"},{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"EDB7602Q"}],"SWKeys":[{"Name":"MZ1LB3T8HMLA-00007","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"aa09ce6818eb43509673c73cdf28ced5"}]},{"ProductId":"d3fcc87b38304a8db3d98d71c7c32227","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"VMware ESXi 8.0 Update 3 Mellanox mst driver for Mellanox devices"},{"Lang":"cn","Value":"VMware ESXi 8.0 Update 3 Mellanox mst driver for Mellanox devices"},{"Lang":"ja","Value":"VMware ESXi 8.0 Update 3 Mellanox mst driver for Mellanox devices"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"33088","DateModified":"2025-03-19T08:50:54","FileList":["/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip","/cp052054.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vib20/nmst/MEL_bootbank_nmst_4.31.0.150-1OEM.801.0.0.21495797.vib","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vibs/nmst--3413091292116279482.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797.xml"],"MD5Sum":"34dc15abf72ecba71284150a2c32fd45","Name":"cp052054.zip","Release":"2025-03-19T08:49:53","Revision":"","SHA1Sum":"e2cb73ef1d2b4f19e1917c4e7ce10857d0ea5f64","SHA256Sum":"adaa13260e578d353ef947519b19e9ceb8510f63c87058ffa9a70584ee8e6986","Size":"32KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.1"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299","20a6e8e4-bf33-4c71-a6bf-d9ecd0345028"],"TypeOfChange":"1","Version":"2025.03.17","VibList":[{"Name":"nmst","Version":"4.31.0.150-1OEM.801.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"},{"Lang":"cn","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"},{"Lang":"ja","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"net-mst kernel module driver component for VMware ESXi 8.0 Update 3"},{"Lang":"cn","Value":"net-mst kernel module driver component for VMware ESXi 8.0 Update 3"},{"Lang":"ja","Value":"net-mst kernel module driver component for VMware ESXi 8.0 Update 3"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"8020","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c8020","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"801F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c801f","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F4","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f4","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F2","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f2","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f3","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"22F5","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f5","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f1","Type":"pci","Ven":"15b3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"0221","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101315900221","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2022-06-09T04:27:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 8.0 Update 3&nbsp;only.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 8.0 Update 3&nbsp;only.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 8.0 Update 3&nbsp;only.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.17"}],"SWKeys":[{"Name":"nmst:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"Mellanox-NATIVE-NMST:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"I38","Model":"HPE ProLiant BL660c Gen9 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant BL460c Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"","Model":"HPE Apollo sx40 Server"},{"Family":"","Model":"HPE Apollo pc40 Server"},{"Family":"","Model":"HPE Apollo kl20 Server"},{"Family":"","Model":"HPE Apollo am35 Server"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"710b214b710b478db82f6f2cc0c9f094"}]},{"ProductId":"29a000381a7c4ec8a72063a155821a0a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するIntel ice Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1128109","DateModified":"2025-09-15T16:03:46","FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.49.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/ice","./lib/modules/6.4.0-150700.51-default/updates/ice/ice.ko","./usr/share/doc/packages/ice","./usr/share/doc/packages/ice/COPYING","./usr/share/doc/packages/ice/README","./usr/share/doc/packages/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/ice-kmp-default/component.xml"],"MD5Sum":"f147b052681fdad1cab597270bae7610","Name":"ice-kmp-default-2.3.10_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-09-15T15:52:05","Revision":"","SHA1Sum":"43afcf6134c2cf36d858ab39fe2a35b0fc7ac322","SHA256Sum":"8e030f177ff2f996f9f688899297673672fa40391c5438bf83546661cf4e44d0","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"2.3.10-1"},{"Bytes":"1127175","DateModified":"2025-09-15T15:59:28","FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.49.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/ice","./lib/modules/6.4.0-150600.21-default/updates/ice/ice.ko","./usr/share/doc/packages/ice","./usr/share/doc/packages/ice/COPYING","./usr/share/doc/packages/ice/README","./usr/share/doc/packages/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/ice-kmp-default/component.xml"],"MD5Sum":"1a35f6dde62aefab50b60c542051040d","Name":"ice-kmp-default-2.3.10_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-09-15T15:52:05","Revision":"","SHA1Sum":"74cc65b6e2c16a82bbc665bea68dbc85d6176ba5","SHA256Sum":"e30d0f5f9d4fb705321ad9875e89f42c0f2b8da54bde2846009e60df86b9a1c6","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"2.3.10-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Intel ice Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"Intel iceドライバーfor SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"Intel ice Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"},{"Dev":"12D3","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-12d380860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-22T08:02:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Software Cross Timestamping feature for E810.</p>","Fixes":"<p>This product fixed an issue where the &#39;ethtool ethx&#39; displayed &#39;AUI&#39; with AOC cable, should display &#39;Fibre&#39;.</p>","Lang":"en"},{"Enhancements":"<p>この製品は、E810のソフトウェアクロスタイムスタンプ機能をサポートするようになりました。</p>","Fixes":"<p>この製品では、AOC ケーブル使用で「ethtool ethx」を実行すると、「Fibre」と表示されるはずが「AUI」と表示される問題が修正されました。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports Software Cross Timestamping feature for E810.</p>","Fixes":"<p>This product fixed an issue where the &#39;ethtool ethx&#39; displayed &#39;AUI&#39; with AOC cable, should display &#39;Fibre&#39;.</p>","Lang":"cn"}],"Version":"1.17.8-1"},{"ReleaseNotes":[{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.3.10-1"}],"SWKeys":[{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"03356d8eed65448eb25fed65b457595c"}]},{"ProductId":"660aa31b4e5e4c7fa47517faf21f93a1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB016000GWXKK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB016000GWXKK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000GWXKK&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000GWXKK&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19500510","DateModified":"2025-03-07T11:17:13","FileList":["/CP065948_BUILD_4.data","/CP065948.vmexe64","/CP065948.vmfile","/CP065948_VMw.zip","/CP065948.xml","/payload.json","/CP065948_VMw.zip/index.xml","/CP065948_VMw.zip/vendor-index.xml","/CP065948_VMw.zip/metadata.zip","/CP065948_VMw.zip/vib20/CP065948/HPE_bootbank_CP065948_HPG4.4-1OEM.800.1.0.20613240.vib","/CP065948_VMw.zip/metadata.zip/vendor-index.xml","/CP065948_VMw.zip/metadata.zip/vmware.xml","/CP065948_VMw.zip/metadata.zip/vibs/CP065948-5843835157085481538.xml","/CP065948_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065948_HPG4.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"408d81d072da9ce24ddf32e0e5e32420","Name":"CP065948.zip","Release":"2025-03-07T11:16:24","Revision":"C","SHA1Sum":"9f9d347e952a2a5a343835bedcf135c8ea25ca0c","SHA256Sum":"9c7c9394a9a24cb9b21128af1b680f67c5f25852b93011fefed9aff19ac88782","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP065948","Version":"HPG4.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB016000GWXKK Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB016000GWXKKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB016000GWXKK","TargetGUID":"4d2340a5-3042-3631-3030-304757584b4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:34:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f71d0aa764ae4c37b94b0a977af328e9"}]},{"ProductId":"0f2b8614c6ab40aea6c15cd633ff1402","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWJAN、MB002000GWFWA および MB004000GWFWB ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"18843809","DateModified":"2025-03-06T10:53:00","FileList":["/CP065995_BUILD_2.data","/CP065995.vmexe64","/CP065995.vmfile","/CP065995_VMw.zip","/CP065995.xml","/payload.json","/CP065995_VMw.zip/index.xml","/CP065995_VMw.zip/vendor-index.xml","/CP065995_VMw.zip/metadata.zip","/CP065995_VMw.zip/vib20/CP065995/HPE_bootbank_CP065995_HPG1.2-1OEM.800.1.0.20613240.vib","/CP065995_VMw.zip/metadata.zip/vendor-index.xml","/CP065995_VMw.zip/metadata.zip/vmware.xml","/CP065995_VMw.zip/metadata.zip/vibs/CP065995--7969129075819612975.xml","/CP065995_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065995_HPG1.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"a00accef6240fc0e9dd765b5b4ae6248","Name":"CP065995.zip","Release":"2025-03-06T10:52:13","Revision":"K","SHA1Sum":"4be86ef24938cc396257bee3c50fea78b26cc36c","SHA256Sum":"7847597d43089fa4b2c97a2768321327e8bf38003dfb1cc1c7e18ed5460df2ab","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065995","Version":"HPG1.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040691.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000GWFWB","TargetGUID":"4d2340a5-3042-3430-3030-304757465742","Type":"sata"},{"Id":"MB002000GWFWA","TargetGUID":"4d2340a5-3042-3230-3030-304757465741","Type":"sata"},{"Id":"MB001000GWJAN","TargetGUID":"4d2340a5-3042-3130-3030-3047574a414e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:23:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8fff860ffbd24a8098156de57480237f"}]},{"ProductId":"d217387da75b452f91f63bc9a4605e37","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.624.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"ja","Value":"HPE Storageファイバーチャネル（FC）アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター（HBA）ドライバーを提供する、バージョン14.4.624.0 のEmulex Storportドライバーfor Extended Systemが含まれています。"},{"Lang":"cn","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.624.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4294248","DateModified":"2025-11-24T08:45:16","FileList":["cp066303.xml","cpqsetup.exe","elxdrvr-fc-14.4.624.0-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"MD5Sum":"d15bcbc9d37377880e6879c20e949b9b","Name":"cp066303.exe","Release":"2025-11-24T08:43:06","Revision":"","SHA1Sum":"875204a9fc2e746f45cc6c117aadfaa0fb2e1f93","SHA256Sum":"9ad911c4be4a9cb7f11641d893ce136080e66f20ba933f751c79bf764177c95d","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.624.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>［インストール］ボタンをクリックして、インストールを開始します。</p><p> </p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2019"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T12:12:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br />&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.393.20にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br /> </p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br />&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.393.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.624.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br />&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.624.0にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>    elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br /> </p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.624.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br />&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.624.0"}],"SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"066f16414103423396e99ff4090c6596"}]},{"ProductId":"eb66fafd28ff4c39a42b91395104bd05","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4926257","DateModified":"2025-11-11T09:20:11","FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"MD5Sum":"70f2b68553799915ddc1e090fc4a5c1c","Name":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-11-11T09:13:03","Revision":"","SHA1Sum":"12dda8adb3ce8996e5c68af5660a4b792a6d10d0","SHA256Sum":"6071be4257c3f9a77b0ee523bdfde0e97a54bcfc368d30454ba4bf6ff3e24ad7","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.15.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k5.14.21_150400.22-1.sles15sp7.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k5.14.21_150400.22-1.sles15sp7.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k5.14.21_150400.22-1.sles15sp7.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"SuSE Linux Enterprise Server 15 Service Pack 7ファイバーチャネルドライバーキットfor HPE QLogicホストバスアダプター"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T07:04:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.15.00-k1"}],"SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3829a63eceed47e4a618463a0a5f99f2"}]},{"ProductId":"cd60e68416444c61a56b3c63cb2d1ca3","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8336234","DateModified":"2025-12-16T17:11:16","FileList":["/CP069039_BUILD_2.data","/CP069039.vmcfg","/CP069039.vmexe64","/CP069039.vmfile","/CP069039_VMw.zip","/CP069039.xml","/payload.json","/CP069039_VMw.zip/index.xml","/CP069039_VMw.zip/vendor-index.xml","/CP069039_VMw.zip/metadata.zip","/CP069039_VMw.zip/vib20/CP069039/HPE_bootbank_CP069039_5.04.2-8.0.0.20613240.vib","/CP069039_VMw.zip/metadata.zip/vendor-index.xml","/CP069039_VMw.zip/metadata.zip/vmware.xml","/CP069039_VMw.zip/metadata.zip/vibs/CP069039--1890418364887592542.xml","/CP069039_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069039_5.04.2-8.0.0.20613240.xml"],"MD5Sum":"5c34180232cd738bc28a4cd0e4d81297","Name":"CP069039.zip","Release":"2025-12-16T17:08:07","Revision":"N","SHA1Sum":"cd695d6e4b5d9a95a5d397717271dd43ccbc2003","SHA256Sum":"e45ff5749d7e67185b07902bc2714140ed50188a5cb23a86a6960217c72a536a","Size":"7MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04","VibList":[{"Name":"CP069039","Version":"5.04.2-8.0.0.20613240"}]}],"Installation":{"Command":"setup","CommandParams":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275184/20-D3000-Gen10RN504O_ED15.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275184/20-D3000-Gen10RN504O_ED15.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275184/20-D3000-Gen10RN504O_ED15.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"cn","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"ja","Value":"VMware (ESXi)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3600","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Type":"sas"},{"Id":"D3610","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3700","TargetGUID":"b99dfb74-f0bc-464f-b418-cd186af467e1","Type":"sas"},{"Id":"D3710","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-06T07:26:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li><p>Enabled-ClusterS2Dコマンドは、NonStopソリューションのD3610ディスクエンクロージャー内のSATAドライブ上で実行すると正常に完了するようになりました。</p></li><li><p>SASドライブのドライブケースであるスマートキャリアは、D3610/D3710ドライブエンクロージャーで認証されるようになりました。</p></li><li><p>ファンモジュールAおよびBの問題を報告するために、新しい7セグメントエラーコードE0およびE1がそれぞれ追加されました。これらの新しいコードはD3610/D3710にのみ適用され、ファームウェア5.04を実行しているときにのみ表示されます。</p></li><li><p>I/Oモジュール内のストレージエンクロージャープロセッサーに障害が発生すると、プロセッサーを確実にオンラインに戻すために、ハードリセット（電源を切ってから電源を入れる）が実行されます。</p></li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"},{"ReleaseNotes":[{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275184/20-D3000-Gen10RN504O_ED15.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p>ESXi 9.0のサポートを追加しました</p><p>ESXi 7.0のサポートを削除しました</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275184/20-D3000-Gen10RN504O_ED15.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275184/20-D3000-Gen10RN504O_ED15.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"}],"SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cacdb2be5e8b41248e2f8d80781873a9"}]},{"ProductId":"28a7be894d024552967d8ce99ed30ca6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Ubuntu&nbsp;Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"4881784","DateModified":"2025-08-03T01:10:23","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-1.1/CP067334.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-1.1/KACM6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067334.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067334.scexe"],"MD5Sum":"b90cd53215bbf0c357d6a7088ad89a1a","Name":"firmware-hdd-3815d4b024_0GPK8-1.1_amd64.deb","Release":"2025-08-03T06:03:05","Revision":"","SHA1Sum":"73d9ae07ed04312e40ac466368bef247c520224f","SHA256Sum":"f9e69748b8cedc35e50ac5b865035839754a2f6478ec46d37dc2f977b5b291f9","Size":"4MB","TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6XRUL960G","TargetGUID":"002340a5-434b-364d-5852-554c39363047","Type":"nvme"},{"Id":"KCM6XRUL7T68","TargetGUID":"002340a5-434b-364d-5852-554c37543638","Type":"nvme"},{"Id":"KCM6XRUL1T92","TargetGUID":"002340a5-434b-364d-5852-554c31543932","Type":"nvme"},{"Id":"KCM6XVUL3T20","TargetGUID":"002340a5-434b-364d-5856-554c33543230","Type":"nvme"},{"Id":"KCM6XRUL3T84","TargetGUID":"002340a5-434b-364d-5852-554c33543834","Type":"nvme"},{"Id":"KCM6XVUL800G","TargetGUID":"002340a5-434b-364d-5856-554c38303047","Type":"nvme"},{"Id":"KCM6XVUL6T40","TargetGUID":"002340a5-434b-364d-5856-554c36543430","Type":"nvme"},{"Id":"KCM6XVUL1T60","TargetGUID":"002340a5-434b-364d-5856-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:59:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK8"}],"SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"06f9b06ef94c48a78ab38e8e64adf569"}]},{"ProductId":"2e5a37814cc1401a951db2b5be91b6b3","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK7</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK7</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK7</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6294363","DateModified":"2025-09-21T21:39:31","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/CP068920.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/KACD6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068920.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068920.scexe"],"MD5Sum":"997affbd420ce78f0e2702222d84d1a4","Name":"firmware-hdd-6fc985bd3b-GPK8-4.1.x86_64.rpm","Release":"2025-09-22T02:29:14","Revision":"D","SHA1Sum":"4e3b9f5caa71ece323a7e4874769839b6158dc6d","SHA256Sum":"e4e70ee788f00bcedbf62137e058ca311fe3ea58aa47907359a927ca10ae76de","Size":"6MB","TargetGUIDs":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCD6XLUL7T68","TargetGUID":"002340a5-434b-3644-584c-554c37543638","Type":"nvme"},{"Id":"KCD6XVUL6T40","TargetGUID":"002340a5-434b-3644-5856-554c36543430","Type":"nvme"},{"Id":"KCD6XVUL1T60","TargetGUID":"002340a5-434b-3644-5856-554c31543630","Type":"nvme"},{"Id":"KCD6XVUL800G","TargetGUID":"002340a5-434b-3644-5856-554c38303047","Type":"nvme"},{"Id":"KCD6XVUL3T20","TargetGUID":"002340a5-434b-3644-5856-554c33543230","Type":"nvme"},{"Id":"KCD6XLUL960G","TargetGUID":"002340a5-434b-3644-584c-554c39363047","Type":"nvme"},{"Id":"KCD6XLUL1T92","TargetGUID":"002340a5-434b-3644-584c-554c31543932","Type":"nvme"},{"Id":"KCD6XLUL3T84","TargetGUID":"002340a5-434b-3644-584c-554c33543834","Type":"nvme"},{"Id":"KCD6XVUL12T8","TargetGUID":"002340a5-434b-3644-5856-554c31325438","Type":"nvme"},{"Id":"KCD6XLUL15T3","TargetGUID":"002340a5-434b-3644-584c-554c31355433","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:00:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>リセットの問題と定期的なメンテナンスファームウェアアップデートを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK8"}],"SWKeys":[{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b5a913647d7640cd9a84628e9c1a43c4"}]},{"ProductId":"1e88e3b27b814bcdbc8dcf6390d324d1","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM4 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM4_1.24_G.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901504000000","Version":"1.24"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains PLDM firmware for UBM4 storage backplanes."},{"Lang":"ja","Value":"This firmware package contains PLDM firmware for UBM4 storage backplanes."},{"Lang":"cn","Value":"This firmware package contains PLDM firmware for UBM4 storage backplanes."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"62652","DateModified":"2024-09-13T04:58:18","FileList":["HPE_UBM4_1.24_G.HPb","HPE_UBM4_1.24_G.xml","payload.json"],"MD5Sum":"028965ae0744c5bd9edba939bf775db9","Name":"HPE_UBM4_1.24_G.fwpkg","Release":"2024-09-13T04:53:37","Revision":"G","SHA1Sum":"f08bde255f56cfe95a4cb7cfb0c0c04754b9c24e","SHA256Sum":"21ad95f2ae46d3a5417a5bfa43832a676dde21e588070459bdfa5cf2778c62e1","Size":"61KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901504000000"],"TypeOfChange":"1","Version":"1.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - UBM4 Backplane PIC PLDM Firmware for Gen10P/Gen11/Gen12 servers usage"},{"Lang":"ja","Value":"Firmware Package - UBM4 Backplane PIC PLDM Firmware for Gen10P/Gen11/Gen12 servers usage"},{"Lang":"cn","Value":"Firmware Package - UBM4 Backplane PIC PLDM Firmware for Gen10P/Gen11/Gen12 servers usage"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901504000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-12T08:36:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>For Gen11 PR3 &amp; 2023 March MSB</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>For Gen11 PR3 &amp; 2023 March MSB</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>For Gen11 PR3 &amp; 2023 March MSB</p>","Fixes":"","Lang":"cn"}],"Version":"1.24"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Support Gen12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support Gen12 servers.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support Gen12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.24"}],"SWKeys":[{"Name":"UBM4PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"R11","Model":"HPE ProLiant RL300 Gen11"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"4e14138c4c714237bcc8bfb333533ccd"}]},{"ProductId":"13362528154f414b9954d2c4772da522","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following SATA drive model: MM1000GFJTE"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following SATA drive model: MM1000GFJTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MM1000GFJTE Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MM1000GFJTE Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4112924","DateModified":"2025-08-03T02:12:58","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-1.1/CP067348.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-1.1/SAVGNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067348.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067348.scexe"],"MD5Sum":"9aa31ced1694710e9611b8bca01a561a","Name":"firmware-hdd-95af9a555e_0HPG6-1.1_amd64.deb","Release":"2025-08-03T07:03:43","Revision":"","SHA1Sum":"82b68d26c9bbd9074a9c695bc8d7923e80c73e1a","SHA256Sum":"b5f36d3b9ce872aa7da3c61b2f3e9e30293a5742f047990d510e295d2ef04135","Size":"3MB","TargetGUIDs":["002340a5-4d00-314d-3030-3047464a5445"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP040344.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MM1000GFJTE Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MM1000GFJTE Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM1000GFJTE","TargetGUID":"002340a5-4d00-314d-3030-3047464a5445","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:40:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul>","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MM1000GFJTE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e6962e9eba8541f2b5d8f84f4091bfc0"}]},{"ProductId":"36877a0ed97d40a29cfe6cb469a6e72f","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U32_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11837296","DateModified":"2026-01-14T09:18:44","FileList":["cp070222.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U32_3.62_01_09_2026.signed.flash"],"MD5Sum":"91d30536c258b59cc71276e588aabd2d","Name":"cp070222.exe","Release":"2026-01-14T09:16:58","Revision":"","SHA1Sum":"a0befd6b799cc510be449314ff14d17cf86fc9d4","SHA256Sum":"95353c4645070b036d47e1d08286932f275019bb7480b3813081afeb61ad945e","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL360 Gen10 (U32)サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:19:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"b5c0ec0c4861445791a24a401e4eb824"}]},{"ProductId":"614a0c688deb4def90dafbe34fab64bb","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"HPE Smart Array and Smart RAID controller driver component for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE SmartアレイおよびSmart RAIDコントローラードライバーコンポーネントfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Smart Array and Smart RAID controller driver component for VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"420680","DateModified":"2025-12-23T07:02:09","FileList":["/cp069364.xml","/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.zip","/MIS_bootbank_smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.vib","/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.zip/index.xml","/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.zip/metadata.zip","/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.zip/vib20/smartpqi/MIS_bootbank_smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.vib","/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/smartpqi-346418241294848364.xml","/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Microchip-smartpqi_80.4880.0.109-1OEM.800.1.0.20613240.xml"],"MD5Sum":"52c128052e0f21355619731ffcc92492","Name":"cp069364.zip","Release":"2025-12-23T07:00:56","Revision":"","SHA1Sum":"4d857bc2dafc789dcd84ead292814d65ba30809d","SHA256Sum":"5e48c68769585804e299aee42819f9faa3dd28f7da302de26aa046b5ec4f6051","Size":"410KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c","20a6e8e4-bf33-4c71-a6bf-d9ec72979cda"],"TypeOfChange":"1","Version":"2026.01.01","VibList":[{"Name":"smartpqi","Version":"80.4880.0.109-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hp/swpackages and ./hpsum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul><p><br />&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p><p><strong>リモートオンライン：</strong></p><ul><li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li><li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li><li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li><li> CD /hp/swpackagesおよび./hpsum</li><li> 次へボタンを選択します。</li><li> シングルターゲットの追加をクリックします。</li><li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li><li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li> Smart Update Managerの指示に従ってアップデートを行います。</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ul><li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li><li> VUMおよびesxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</li></ul><p><br /> </p>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hp/swpackages and ./hpsum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul><p><br />&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 8.0 (Driver Component)."},{"Lang":"ja","Value":"HPE ProLiant Gen10 SmartアレイおよびGen10 PlusおよびGen11 Smart RAIDコントローラードライバーfor VMware vSphere 8.0 (ドライバーコンポーネント)"},{"Lang":"cn","Value":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 8.0 (Driver Component)."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T09:50:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed PSOD indicates a divide-by-zero happened.&nbsp;</li><li>Fixed an issue where the driver&#39;s controller structure field was too small for the full ASCII firmware version.&nbsp;</li><li>Fixed an issue where a message from a periodic check on the controller heartbeat appeared as a&nbsp;system error instead of an informational message.&nbsp;</li><li>Fixed an issue where firmware versioning information was incorrect or blank on some of the controllers.&nbsp;</li><li>Fixed an issue where in a specific scenario, the device removal handler attempts to remove a device that has already been removed by the normal device discovery flow.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ゼロ除算が発生したことを示すPSODを修正しました。 </li><li>ドライバーのコントローラー構造フィールドが完全なASCIIファームウェアバージョンに対して小さすぎる問題を修正しました。 </li><li>コントローラーのハートビートの定期チェックからのメッセージが情報メッセージではなくシステム エラーとして表示される問題を修正しました。 </li><li>一部のコントローラーでファームウェアのバージョン情報が間違っていたり空白だったりする問題を修正しました。 </li><li>特定のシナリオにおいて、デバイス削除ハンドラーが、通常のデバイス検出フローによってすでに削除されているデバイスを削除しようとする問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed PSOD indicates a divide-by-zero happened.&nbsp;</li><li>Fixed an issue where the driver&#39;s controller structure field was too small for the full ASCII firmware version.&nbsp;</li><li>Fixed an issue where a message from a periodic check on the controller heartbeat appeared as a&nbsp;system error instead of an informational message.&nbsp;</li><li>Fixed an issue where firmware versioning information was incorrect or blank on some of the controllers.&nbsp;</li><li>Fixed an issue where in a specific scenario, the device removal handler attempts to remove a device that has already been removed by the normal device discovery flow.</li></ul>","Lang":"cn"}],"Version":"2025.10.01"},{"ReleaseNotes":[{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2026.01.01"}],"SWKeys":[{"Name":"Microchip-smartpqi:80.4880.0.109-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"smartpqi:80.4880.0.109-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2ddbb9895d1240bd95290044d55545dd"}]},{"ProductId":"c0403221bbc14b609f9dc339f216be5e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MM1000GFJTE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000GFJTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br /><br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br /><br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br /><br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br /><br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19186095","DateModified":"2025-03-06T06:07:03","FileList":["/CP066002_BUILD_3.data","/CP066002.vmexe64","/CP066002.vmfile","/CP066002_VMw.zip","/CP066002.xml","/payload.json","/CP066002_VMw.zip/index.xml","/CP066002_VMw.zip/vendor-index.xml","/CP066002_VMw.zip/metadata.zip","/CP066002_VMw.zip/vib20/CP066002/HPE_bootbank_CP066002_HPG6.3-1OEM.800.1.0.20613240.vib","/CP066002_VMw.zip/metadata.zip/vendor-index.xml","/CP066002_VMw.zip/metadata.zip/vmware.xml","/CP066002_VMw.zip/metadata.zip/vibs/CP066002-8352906547692875396.xml","/CP066002_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066002_HPG6.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"5f7cbd5644245c700e5828ec381f004a","Name":"CP066002.zip","Release":"2025-03-06T06:06:14","Revision":"E","SHA1Sum":"91d3e1c35a3f8473f9626b05fde6c85dbe7beca7","SHA256Sum":"aa49d4039d92653428e9cb770a9b841c37e232d1eb399c3374caf0ac25b3d955","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-4d00-314d-3030-3047464a5445"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP066002","Version":"HPG6.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041026.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MM1000GFJTEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MM1000GFJTE","TargetGUID":"002340a5-4d00-314d-3030-3047464a5445","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:01:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MM1000GFJTE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f892951743024df2afb45434cce22ed5"}]},{"ProductId":"aedcdb1596004cf4a73ef573a3625e08","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.5"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5733831","DateModified":"2025-12-02T11:27:05","FileList":["/CP068477_BUILD_6.data","/CP068477.vmexe","/CP068477.vmexe64","/CP068477.vmfile","/CP068477_VMw.zip","/CP068477.xml","/payload.json","/CP068477_VMw.zip/index.xml","/CP068477_VMw.zip/vendor-index.xml","/CP068477_VMw.zip/metadata.zip","/CP068477_VMw.zip/vib20/CP068477/HPE_bootbank_CP068477_2025.11.01.6-8.0.0.20613240.vib","/CP068477_VMw.zip/metadata.zip/vendor-index.xml","/CP068477_VMw.zip/metadata.zip/vmware.xml","/CP068477_VMw.zip/metadata.zip/vibs/CP068477-3854131574211459732.xml","/CP068477_VMw.zip/metadata.zip/bulletins/Smart-Component-CP068477_2025.11.01.6-8.0.0.20613240.xml"],"MD5Sum":"4bdefaa92963a5d5e6106df9f345f872","Name":"CP068477.zip","Release":"2025-12-02T11:22:58","Revision":"","SHA1Sum":"3d7868a54b01a8e0aec66d6dbc2e04e55e4327a2","SHA256Sum":"c63e79dd143bd52fe36a9f73971678b5aae0f05a9867601f8cfee356364bd77f","Size":"5MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2025.11.01","VibList":[{"Name":"CP068477","Version":"2025.11.01.6-8.0.0.20613240"}]}],"Installation":{"Command":"hpsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />Offline:</strong></p><ul><li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li></ul><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li><li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li><li>From the same directory, unzip the Smart Component.<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li><li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>To perform the standalone installation, execute the command:</li><li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li><li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:<ul><li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li></ul></li><li>To perform standalone installation of the firmware,Execute the command:<ul><li>./ Execute_Component</li></ul></li><li>Follow the directions given by the Smart Component</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host</li><li>Reboot your system, if required, for the firmware update to take effect</li></ul>"},{"Lang":"ja","Value":"<p><strong>HP Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください。<br />オフライン：</strong></p><ul><li>Service Pack ProLiantオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます</li></ul><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデートするESXiホストのIPまたはDNSアドレスを入力するか（ESXiホストがGen9サーバーの場合）、ESXiホストのiLOのIPまたはDNSアドレスを入力します（サーバーがGen10以上の場合）</li><li>Gen9/Gen10以上に基づいてESXiホスト/iLO認証情報（rootまたは管理者のユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li><li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p><ul><li>vSphereクライアントにログインします。</li><li>インベントリツリーのサーバーまたはクラスターを選択します。</li><li>HPE Insight Managementタブをクリックします。</li><li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li></ul><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>ESXiホスト上のTech Support Modeを有効にします。</li><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>Smartコンポーネント（CPxxxxxx.zip）を一時ディレクトリに置きます。</li><li>同じディレクトリからSmartコンポーネントをunzipします。<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>Smartコンポーネントには、ファームウェアのインストールを実行するためにインストールする必要のあるVIBで構成されたCPxxxxx_VMw.zipが含まれています</li><li>CPxxxxxx_VMw.zipファイルが実行可能であることを確認します。次のコマンドを実行します：<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>スタンドアロンのインストールを行うために、次のコマンドを実行します：</li><li>esxcli software vib install -d /<path_of_CPxxxxxx_VMw.zip>/CPxxxxxx_VMw.zip</li><li>インストールが完了したら、ディレクトリを/opt/Smart_Component/<CPxxxxxx>に変更します。次のコマンドを実行します：<ul><li>cd /opt/Smart_Component/<CPxxxxxx></li></ul></li><li>ファームウェアのスタンドアロンのインストールを行うために、次のコマンドを実行します：<ul><li>./ Execute_Component</li></ul></li><li>Smartコンポーネントの指示に従います。</li><li>ログアウトします。</li><li>ESXiホスト上のTech Support Modeを無効にします。</li><li>必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  8.0"},{"Lang":"ja","Value":"HPE ファームウェアフラッシュ for Emulex ファイバーチャネルホストバスアダプターfor VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"20000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-21T09:52:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>Fixed the Following:</p><ol><li>Switch Login Incomplete After Firmware Upgrade</li><li>Boot Incomplete on RHEL 10</li></ol>","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>以下を修正しました。</p><ol><li>ファームウェアのアップグレード後にスイッチのログインが完了できない</li><li>RHEL 10でブートが完了できない</li></ol>","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>Fixed the Following:</p><ol><li>Switch Login Incomplete After Firmware Upgrade</li><li>Boot Incomplete on RHEL 10</li></ol>","Lang":"cn"}],"Version":"2025.09.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.11.01"}],"SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0e193713a6044a99a9c3686086cf1d26"}]},{"ProductId":"14db461db87a4c46b9be1a6560ae1f85","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 9.0"},{"Lang":"ja","Value":"この製品は、VMware vSphere 9.0上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;2.11.1.0.</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;2.11.1.0.</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;2.11.1.0.</p>"}],"Files":[{"Bytes":"266272","DateModified":"2025-09-23T06:11:53","FileList":["/cp068941.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/index.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/vib20/i40en/INT_bootbank_i40en_2.11.1.0-1OEM.900.0.24755229.vib","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/i40en-824206042229324044.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.xml"],"MD5Sum":"d248f2ffb9a9d2d4096c69ef20a74ccb","Name":"cp068941.zip","Release":"2025-09-23T06:11:42","Revision":"","SHA1Sum":"88f7256b0628ee83e5f3025b8d92d8fd53240e71","SHA256Sum":"a490c9d5aab817b0173bb384d9ee300988ae61ab26d3300a0f5ad0dfde7d1199","Size":"260KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"i40en","Version":"2.11.1.0-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40en Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE Intel i40enドライバーfor VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE Intel i40en Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T01:57:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version for VMware 9.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>VMware 9.0の初期バージョン。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version for VMware 9.0.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"Intel-i40en:2.11.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.11.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d334abf4b041473783a6d9955dbbdfc7"}]},{"ProductId":"52c884546e0a44fb8cddfd654ad71e81","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U60_2.52_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.52 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17138188","DateModified":"2026-01-13T02:15:51","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.52_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.52_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.52_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.52_2026_01_09-1.1/CP070165.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.52_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.52_2026_01_09-1.1/U60_2.52_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.52_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.52_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.52_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070165.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070165.scexe"],"MD5Sum":"06ddb96e7d83585e4d323131c0f587be","Name":"firmware-system-u60-2.52_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T08:05:33","Revision":"","SHA1Sum":"2c9ad0a010256c7f0d0276707c438b4f359d0897","SHA256Sum":"ad44e3f974f9703f42a8234c85909dd67af4469acf6495584f062c18606e7dbd","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.52_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Proliant DL20 Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL20 Gen10 Plus サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Proliant DL20 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T06:10:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.708（2.50_07_25_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.708 (2.50_07_25_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_01-09-2026"}],"SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2863fa918a0a4a08b75ea40c5db5b173"}]},{"ProductId":"5f87cfcaa78847d59e1bfff7203034fc","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."},{"Lang":"ja","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."},{"Lang":"cn","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"}],"Files":[{"Bytes":"2648698","DateModified":"2025-10-22T08:43:21","FileList":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-testmod.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/fwctl.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"MD5Sum":"0231c8c78c8699dfa30db7b98b2adb67","Name":"kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm","Release":"2025-10-22T06:56:59","Revision":"","SHA1Sum":"9a89bdf1b66facdec0f66e4337ca937a3e113bf9","SHA256Sum":"7d57add118b27f0fa9a02f0ba82e2d7ae31bcc0ba65fa0a64e62db37485253d6","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"25.07-0.9.7.0"},{"Bytes":"1723827","DateModified":"2025-10-22T08:39:50","FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/19","./usr/lib/.build-id/19/e00849d382945300f47addf7c041f8ab33327f","./usr/lib/.build-id/19/ff7293edd308e50b2c56c1b2329b3086bd5f6b","./usr/lib/.build-id/23","./usr/lib/.build-id/23/f8c5eaff3fe1cb26f4c1bad5d1d3633a0e9e29","./usr/lib/.build-id/35","./usr/lib/.build-id/35/2b7aef0b67382e2baf904b14cbb8d30ea4cce7","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/d584afedf98bb86d1964a86d3ac525ea020fbf","./usr/lib/.build-id/45","./usr/lib/.build-id/45/851f30c46c9f78dfed1521ec0e6ca453137a1f","./usr/lib/.build-id/49","./usr/lib/.build-id/49/7b7dc1fdd7ee061b24bfff8d0c755ba18431da","./usr/lib/.build-id/4c","./usr/lib/.build-id/4c/12f09b4abe74f328e981d3ae5732377935aa7f","./usr/lib/.build-id/5c","./usr/lib/.build-id/5c/39892eeb614b480fe0a4212dfd4e101d3420c3","./usr/lib/.build-id/7e","./usr/lib/.build-id/7e/99eb6a22ef5a230e37aeca4e5724f7a12cce89","./usr/lib/.build-id/93","./usr/lib/.build-id/93/2f7a274d5187f4d08ddbbb3e9aad8fc4de061c","./usr/lib/.build-id/99","./usr/lib/.build-id/99/827950b77f83a4abdf8cd76e393a6bc41a1446","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/22ea6180bbad269284bec78dce2a05c16235b7","./usr/lib/.build-id/aa","./usr/lib/.build-id/aa/0611f5def3572b931d373bcb24092cdfea54a9","./usr/lib/.build-id/aa/7a6b43004aa61adc776fd672aa78424a911f81","./usr/lib/.build-id/ab","./usr/lib/.build-id/ab/b95b2d5bee4f593a1fa4010575ab0859d3317c","./usr/lib/.build-id/d4","./usr/lib/.build-id/d4/95d63911355c8432911872d46e48b652617cde","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/352d052398abddb4917da59966f58ee9d4183b","./usr/lib/.build-id/fc","./usr/lib/.build-id/fc/8e613cf7be02a546268a2f4495bcc03cc97e08","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/67a1591c4356035e8f9f928d726c868edeb626","./usr/lib/.build-id/fe/bc3fadce7b53be96f9bb3135d47b8bc24de9d5","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.3.58.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.58.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.58.0","./usr/lib64/libibverbs/libmlx5-rdmav57.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.58.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.25.58.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.58.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/mlnx-ofa_kernel","./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/perftest","./usr/share/doc/perftest/COPYING","./usr/share/doc/perftest/README","./usr/share/doc/perftest/runme","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"MD5Sum":"f65f61a94268ae8c524f4d4d9aa7fa02","Name":"mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm","Release":"2025-10-22T06:56:59","Revision":"","SHA1Sum":"7de16ef7c075d84641c4bc09609d66902328cc21","SHA256Sum":"750a675b0379d061dafa78e6cd88163c8c668bdf34b1b7b3533bd962677665e5","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"25.07-0.9.7.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"Name":"Linux","Value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"Name":"Linux","Value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"Name":"Linux","Value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"Name":"Linux","Value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.07&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br /><br />To install or upgrade the driver:<br />If using kernel version 5.14.0-570.12.1.el9_6.x86_64&nbsp;or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm&nbsp;kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm&nbsp;</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.07&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br /><br />To install or upgrade the driver:<br />If using kernel version 5.14.0-570.12.1.el9_6.x86_64&nbsp;or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm&nbsp;kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm&nbsp;</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.07&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br /><br />To install or upgrade the driver:<br />If using kernel version 5.14.0-570.12.1.el9_6.x86_64&nbsp;or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm&nbsp;kmod-mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.rhel9u6.x86_64.rpm&nbsp;</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for Red Hat Enterprise Linux 9 Update 6 (x86_64)"},{"Lang":"ja","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for Red Hat Enterprise Linux 9 Update 6 (x86_64)"},{"Lang":"cn","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for Red Hat Enterprise Linux 9 Update 6 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"1023","SubDev":"0002","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102315b30002","Type":"pci","Ven":"15B3"},{"Dev":"1023","SubDev":"0006","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102315b30006","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1021","SubDev":"0073","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30073","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0086","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30086","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30074","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0085","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30085","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-07T12:13:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.04-0.6.1.1:</strong></p><ul><li>Trust Lockdown Health Syndrome: Added a new health syndrome for trust lockdown and expose the CRR bit in the health buffer. When the CRR bit is set, it indicates that the syndrome requires a cold reset for recovery.</li><li>A Single PTP Device per Hardware Clock: PHC is typically shared across multiple functions. Currently, the driver creates a separate PTP device for each network interface sharing the same PHC, resulting in redundancy and added complexity. To address this, a single PTP device is now created to represent the shared PHC when operating in real-time mode.</li><li>Log IB State Transitions: Enhanced visibility into IB device state transitions by adding log messages to the kernel log (dmesg). Each time an IB device changes state, a corresponding message will be logged. For example: &quot;mlx5_0: Port: 1 Link DOWN&quot;.</li><li>Optional-counters Binding Support and New Packets/bytes Counters: Previously, optional counters were available only on a per-link basis. This release introduces the ability to bind optional counters to a specific counter object, enabling users to track optional counters across a specific QP group. Support is provided for both automatic and manual binding modes. In both cases, the optional counters that are bound to the QP are those currently configured on the link at the time of binding. Additionally, four new optional counters that track RDMA ingress and egress traffic are introduced: rdma_tx_bytes; rdma_tx_packets; rdma_rx_bytes; rdma_rx_packets. This functionality is exposed to users via the iproute2 package, which must be updated to support this feature.</li><li>User CAPability (UCAP) API: The User CAPability (UCAP) API introduces a mechanism for creating user contexts with specific firmware privileges. It offers fine-grained control over firmware features by exposing each capability as a character device with root-level read-write access. Root processes can grant users these privileges by allowing access to the corresponding character devices. When a user context is created using a UCAP file descriptor, it inherits the associated privileges. For mlx5, two UCAP character devices are provided, and any user context opened with at least one of them is treated as privileged. To guarantee the execution of privileged commands, non-privileged commands are restricted when a privileged user is active on the device.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.04-0.6.1.1:</strong></p><ul><li>Buffer initialization became a performance bottleneck during the allocation of large buffers, typically when using a high number of QPs with large message sizes. The root cause was the inefficient use of rand(). This has been resolved by replacing it with a faster pseudo-random algorithm.</li><li>A potential deadlock that could occur during the handling of peer memory registration failures.</li><li>The following error occurred when switching to SwitchDev mode: &quot;mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)&quot;</li><li>A sysfs issue that occurred when accessing hardware counters from within a namespace.</li><li>&quot;ibstat&quot; would fail and crash when encountering a non-RoCE/IB device, preventing it from displaying information for the remaining valid RoCE/IB devices.</li><li>Bandwidth degradation in cases of high number of QPs, where polling only 16 CQEs per iteration may not be sufficient to process all completions in time.</li><li>A race condition between firmware syndrome report and driver initialization during boot.</li><li>The driver failed to load when a firmware syndrome was detected during boot.</li><li>The mlnx_tune -l command did not list several operating systems that were in fact supported.</li><li>The kernel did not define TCA_TUNNEL_KEY_ENC_SRC_PORT. To align offload behavior with non-offload, the OVS community introduced a commit ( netdev-offload-tc: Fix offload of tunnel key tp_src) that causes offload to fail if this tunnel attribute is used. Now, any rule with a tunnel set action that includes a tunnel source port can no longer be offloaded.</li><li>LLDP traffic from VFs or BF host PFs was not reaching the representor kernel interfaces.</li><li>Flows where both the inner and outer destination (dst) and/or source (src) MAC addresses were rewritten to the same value, the outer MAC address rewrite was ignored, leading to an outer MAC address of 00:00:00:00:00:00.</li><li>Enabling sFlow with OVN caused OVS to crash.</li><li>OVS crashed unexpectedly after DPUs repeatedly broadcast the error message &ldquo;packet with own source address.&rdquo;</li><li>Changing the hw-offload setting from true to false while ports were configured led to errors reported in the OVS log.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン25.04-0.6.1.1には、次の新機能と変更が含まれています。</strong></p><ul><li>トラストロックダウンヘルスシンドローム：トラストロックダウン用の新しいヘルスシンドロームを追加し、ヘルスバッファー内のCRRビットを公開します。CRRビットが設定されている場合、シンドロームの回復にはコールドリセットが必要であることを示しています。</li><li>ハードウェアクロックごとに1つのPTPデバイス：PHCは通常、複数の機能間で共有されます。現在、ドライバーは同じPHCを共有するネットワークインターフェイスごとに個別のPTPデバイスを作成するため、冗長性があり、複雑さが増しています。この問題を解決するために、リアルタイムモードで動作しているときに共有されたPHCを表す1つのPTPデバイスが作成されるようになりました。</li><li>IB状態遷移のログ：カーネルログ (dmesg) にログメッセージを追加することで、IBデバイスの状態遷移の可視性が向上しました。IBデバイスの状態が変化するたびに、対応するメッセージが記録されます。例えば、\"mlx5_0: Port: 1 Link DOWN\"などです。</li><li>オプションカウンターのバインディングサポートと新しいパケット/バイトカウンター：以前は、オプションカウンターはリンクごとにのみ使用可能でした。このリリースでは、オプションカウンターを特定のカウンターオブジェクトにバインドする機能が導入され、ユーザーは特定のQPグループ全体でオプションカウンターを追跡できるようになりました。自動バインディングモードと手動バインディングモードの両方がサポートされます。どちらの場合も、QPにバインドされるオプションカウンターは、バインド時にリンク上で現在設定されているカウンターです。さらに、RDMAのイングレストラフィックとイーグレストラフィックを追跡する4つの新しいオプションカウンター (rdma_tx_bytes、rdma_tx_packets、rdma_rx_bytes、rdma_rx_packets) が導入されました。この機能はiproute2パッケージを介してユーザーに公開されますが、この機能をサポートするにはこのパッケージをアップデートする必要があります。</li><li>User CAPability (UCAP) API：User CAPability (UCAP) APIは、特定のファームウェア権限を持つユーザーコンテキストを作成するためのメカニズムを導入します。各機能をルートレベルの読み取り/書き込みアクセスを持つキャラクター型デバイスとして公開することで、ファームウェア機能に対するきめ細かな制御を実現します。ルートプロセスでは、対応するキャラクター型デバイスへのアクセスを許可することで、ユーザーにこれらの権限を付与できます。UCAPファイル記述子を使用してユーザーコンテキストが作成されると、ユーザーコンテキストは関連付けられている権限を継承します。mlx5の場合、2つのUCAPキャラクター型デバイスが提供され、そのうちの少なくとも1つを使用して開かれたユーザーコンテキストが特権として扱われます。特権コマンドの実行を保証するために、特権ユーザーがデバイス上でアクティブな場合、非特権コマンドが制限されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン25.04-0.6.1.1で修正されました。</strong></p><ul><li>メッセージサイズの大きい多数のQPを使用する場合など、大きなバッファーの割り当て中に、バッファーの初期化がパフォーマンスのボトルネックになっていました。根本的な原因は、rand() の非効率的な使用でした。この問題は、より高速な疑似ランダムアルゴリズムに置き換えることで解決されました。</li><li>ピアメモリ登録の失敗の処理中に発生する可能性のあるデッドロック。</li><li>SwitchDevモードに切り替える際に次のエラーが発生しました。\"mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)\"</li><li>名前空間内からハードウェアカウンターにアクセスする際に発生したsysfsの問題。</li><li>\"ibstat\"は、RoCE/IB以外のデバイスを見つけると失敗してクラッシュし、残りの有効なRoCE/IBデバイスの情報を表示できなくなります。</li><li>QPの数が多い場合に帯域幅が低下し、反復ごとに16個のCQEをポーリングするだけでは、すべての完了を時間内に処理するのに十分ではない可能性があります。</li><li>ブート中のファームウェアシンドロームレポートとドライバー初期化の間の競合状態。</li><li>ブート中にファームウェアシンドロームが検出されたため、ドライバーのロードに失敗しました。</li><li>mlnx_tune -lコマンドでは、実際にサポートされているいくつかのオペレーティングシステムがリストされませんでした。</li><li>カーネルはTCA_TUNNEL_KEY_ENC_SRC_PORTを定義しませんでした。オフロードの動作を非オフロードと一致させるために、OVSコミュニティは、このトンネル属性が使用されている場合にオフロードが失敗するコミット (netdev-offload-tc：トンネルキーtp_srcのオフロードを修正) を導入しました。これで、トンネルのソースポートを含むトンネルセットアクションを持つすべてのルールはオフロードできなくなります。</li><li>VFまたはBFホストPFからのLLDPトラフィックが、リプレゼンターカーネルインターフェイスに到達していませんでした。</li><li>内部と外部の両方の宛先 (dst) および/または送信元 (src) MACアドレスが同じ値に書き換えられたフローで、外部MACアドレスの書き換えは無視され、外部MACアドレスが00:00:00:00:00:00 になります。</li><li>OVNでsFlowを有効にすると、OVSがクラッシュしました。</li><li>DPUが\"packet with own source address\"というエラーメッセージを繰り返しブロードキャストした後、OVSが予期せずクラッシュしました。</li><li>ポートの設定中にhw-offload設定をtrueからfalseに変更すると、OVSログにエラーが報告されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.04-0.6.1.1:</strong></p><ul><li>Trust Lockdown Health Syndrome: Added a new health syndrome for trust lockdown and expose the CRR bit in the health buffer. When the CRR bit is set, it indicates that the syndrome requires a cold reset for recovery.</li><li>A Single PTP Device per Hardware Clock: PHC is typically shared across multiple functions. Currently, the driver creates a separate PTP device for each network interface sharing the same PHC, resulting in redundancy and added complexity. To address this, a single PTP device is now created to represent the shared PHC when operating in real-time mode.</li><li>Log IB State Transitions: Enhanced visibility into IB device state transitions by adding log messages to the kernel log (dmesg). Each time an IB device changes state, a corresponding message will be logged. For example: &quot;mlx5_0: Port: 1 Link DOWN&quot;.</li><li>Optional-counters Binding Support and New Packets/bytes Counters: Previously, optional counters were available only on a per-link basis. This release introduces the ability to bind optional counters to a specific counter object, enabling users to track optional counters across a specific QP group. Support is provided for both automatic and manual binding modes. In both cases, the optional counters that are bound to the QP are those currently configured on the link at the time of binding. Additionally, four new optional counters that track RDMA ingress and egress traffic are introduced: rdma_tx_bytes; rdma_tx_packets; rdma_rx_bytes; rdma_rx_packets. This functionality is exposed to users via the iproute2 package, which must be updated to support this feature.</li><li>User CAPability (UCAP) API: The User CAPability (UCAP) API introduces a mechanism for creating user contexts with specific firmware privileges. It offers fine-grained control over firmware features by exposing each capability as a character device with root-level read-write access. Root processes can grant users these privileges by allowing access to the corresponding character devices. When a user context is created using a UCAP file descriptor, it inherits the associated privileges. For mlx5, two UCAP character devices are provided, and any user context opened with at least one of them is treated as privileged. To guarantee the execution of privileged commands, non-privileged commands are restricted when a privileged user is active on the device.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.04-0.6.1.1:</strong></p><ul><li>Buffer initialization became a performance bottleneck during the allocation of large buffers, typically when using a high number of QPs with large message sizes. The root cause was the inefficient use of rand(). This has been resolved by replacing it with a faster pseudo-random algorithm.</li><li>A potential deadlock that could occur during the handling of peer memory registration failures.</li><li>The following error occurred when switching to SwitchDev mode: &quot;mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)&quot;</li><li>A sysfs issue that occurred when accessing hardware counters from within a namespace.</li><li>&quot;ibstat&quot; would fail and crash when encountering a non-RoCE/IB device, preventing it from displaying information for the remaining valid RoCE/IB devices.</li><li>Bandwidth degradation in cases of high number of QPs, where polling only 16 CQEs per iteration may not be sufficient to process all completions in time.</li><li>A race condition between firmware syndrome report and driver initialization during boot.</li><li>The driver failed to load when a firmware syndrome was detected during boot.</li><li>The mlnx_tune -l command did not list several operating systems that were in fact supported.</li><li>The kernel did not define TCA_TUNNEL_KEY_ENC_SRC_PORT. To align offload behavior with non-offload, the OVS community introduced a commit ( netdev-offload-tc: Fix offload of tunnel key tp_src) that causes offload to fail if this tunnel attribute is used. Now, any rule with a tunnel set action that includes a tunnel source port can no longer be offloaded.</li><li>LLDP traffic from VFs or BF host PFs was not reaching the representor kernel interfaces.</li><li>Flows where both the inner and outer destination (dst) and/or source (src) MAC addresses were rewritten to the same value, the outer MAC address rewrite was ignored, leading to an outer MAC address of 00:00:00:00:00:00.</li><li>Enabling sFlow with OVN caused OVS to crash.</li><li>OVS crashed unexpectedly after DPUs repeatedly broadcast the error message &ldquo;packet with own source address.&rdquo;</li><li>Changing the hw-offload setting from true to false while ports were configured led to errors reported in the OVS log.</li></ul>","Lang":"cn"}],"Version":"25.04-0.6.1.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"cn"}],"Version":"25.07-0.9.7.0"}],"SWKeys":[{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ba6f2982065d4ddd81b475442f3249e1"}]},{"ProductId":"8dad994cacb24e87b613f12e36f4c8c5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This driver, MegaSAS35, provides Windows 64-bit support for HPE Smart Array MR controllers"},{"Lang":"ja","Value":"このドライバーMegaSAS35は、HPE SmartアレイMRコントローラー用のWindows 64-bitサポートを提供します"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"901408","DateModified":"2025-11-17T05:47:16","FileList":["cp069593.xml","cpqsetup.exe","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"MD5Sum":"bba5fb144c05b39e77b91fc6aa88ba28","Name":"cp069593.exe","Release":"2025-11-17T05:44:30","Revision":"E","SHA1Sum":"e7ed9eec8728536c8efd7a781b75eec6459fea1f","SHA256Sum":"a875b0b965d91fd2b7a4ed4b76c8045afb63fd6e005fdbb879e4faba9976f15f","Size":"880KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.716.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p,MR416i-a, MR216i-p, MR216i-a 64-bit controller driver for Microsoft Windows 2016 edition."},{"Lang":"ja","Value":"HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a 64-bitコントローラードライバーfor Microsoft Windows 2016 edition。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1440"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-14T02:49:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support Gen10P ML30 server and Gen10 DL360/DL380 servers</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Gen10P ML30サーバーおよびGen10 DL360/DL380サーバーをサポート</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support Gen10P ML30 server and Gen10 DL360/DL380 servers</p>","Fixes":"","Lang":"cn"}],"Version":"7.716.3.0"},{"ReleaseNotes":[{"Enhancements":"<p>Fix build tool certification issue.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Fix build tool certification issue.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Fix build tool certification issue.</p>","Fixes":"","Lang":"cn"}],"Version":"7.716.3.0"}],"SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c27bc1c39296469e83cc70adfab7c862"}]},{"ProductId":"1b2f6dbb532f4c6ca53c07209cbe6b16","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE QLogic NX2 10/20 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"},{"Lang":"ja","Value":"<p>この製品には、以下のドライバーが含まれています。</p><ul><li>qfle3バージョン1.4.51.0</li><li>qcnicバージョン2.0.67.0</li><li>qfle3iバージョン2.1.14.0</li><li>qfle3fバージョン2.1.34.0</li></ul>"},{"Lang":"cn","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"}],"Files":[{"Bytes":"1522712","DateModified":"2024-12-10T08:29:53","FileList":["/cp064345.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"MD5Sum":"c6481811688f848dde4e7262f1788016","Name":"cp064345.zip","Release":"2024-12-10T08:29:31","Revision":"","SHA1Sum":"e670856774f0820f8a1650db262f684097d5324f","SHA256Sum":"9f118789dc8e6c1acba834040de98b4b32a09df5d6c9bf47b3832104e3da4d27","Size":"1MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T04:04:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product corrects an issue which fix TSO (TCP Segmentation Offload) issue when single segment is larger than pkt length.</li><li>This product corrects an issue which PSOD while freeing DMA during &#39;esxcli qlfastlinq qcc&#39; command execution.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、単一のセグメントがパケット長より大きい場合に発生するTSO (TCP セグメンテーションオフロード)の問題を修正します。</li><li>この製品は、「esxcli qlfastlinq qcc」コマンドの実行中にDMAを解放すると PSODが発生する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product corrects an issue which fix TSO (TCP Segmentation Offload) issue when single segment is larger than pkt length.</li><li>This product corrects an issue which PSOD while freeing DMA during &#39;esxcli qlfastlinq qcc&#39; command execution.</li></ul>","Lang":"cn"}],"Version":"2024.09.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.03.00"}],"SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"efd45025f131446c8a82a2b5fbf98968"}]},{"ProductId":"b0150fa8c3c74fa8a3415a136a3cc117","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.35.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.35.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.35.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.35.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このパッケージには、Windows Server 2022およびWindows Server 2025で動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"7529880","DateModified":"2025-11-17T02:26:17","FileList":["bcmnicfwupg.exe","BMAPIa.dll","cp069008.xml","cpqsetup.exe","FW/","FW/BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","FW/BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","FW/BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","FW/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"8b577e653af24ae1ceaf5c89069f30ad","Name":"cp069008.exe","Release":"2025-11-17T02:17:32","Revision":"","SHA1Sum":"9a34f9a3159b9bef72d63bfa3d8d0b3335a2f77d","SHA256Sum":"c7171d57e844cee7f1c6c5e992a2e30b694a1301d6ed04b6225baad22d28bc89","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"5.4.6.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 1Gb Driver is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","SWKey":"b57nd60a.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li>ファームウェアのインストール後、アップデートを有効にするためにはAC電源の再投入が必要です。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"Broadcom NX1オンラインファームウェアアップグレードユーティリティfor Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-01T05:41:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"5.4.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number.</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number.</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed<br />&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where unique serial number in VPD (Vital Product Data) will be altered to a dummy serial number.</li><li>This product fixes the issue where Failing to Obtain iLO shared NIC DHCP IP and MCTP EID Missing during Reboot.</li><li>This product fixes the issue where PCI Temperature sensor might be missing intermittently causing Increase in Fan Speed<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"5.4.6.0"}],"SWKeys":[{"Name":"BcmNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U47","Model":"HPE ProLiant DX220n Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DX380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DX325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DX360 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03030202","Model":"HPE Compute Scale-up Server 3250"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"93a11597a6eb4cc582ec0b9f3bb6e566"}]},{"ProductId":"05a81ac262384916b1fa6e922a6cada6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp;&nbsp;&nbsp;This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp;&nbsp;&nbsp;This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6160162","DateModified":"2025-09-21T22:10:36","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/CP068930.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068930.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068930.scexe"],"MD5Sum":"489b614e129df327195fcef48426f2ba","Name":"firmware-hdd-6b7ce3da0e-HPG2-14.1.x86_64.rpm","Release":"2025-09-22T02:58:59","Revision":"N","SHA1Sum":"9ca0feb21f5b356d0325483f791f4b720651628e","SHA256Sum":"d74415ef6caf672dc69f1f7adab7e81e5d8be56ccf7ceb317f984582b8d1f871","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"Installation":{"Command":"CP041455.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000GWRTN","TargetGUID":"4d2340a5-3042-3431-3030-30475752544e","Type":"sata"},{"Id":"MB012000GWRTL","TargetGUID":"4d2340a5-3042-3231-3030-30475752544c","Type":"sata"},{"Id":"MB010000GWRTK","TargetGUID":"4d2340a5-3042-3031-3030-30475752544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:12:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.</li></ul>","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"550deb8b0471468da76947e52e40beca"}]},{"ProductId":"38d3787c49804ab1b404f61b3cd58354","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"3443872","DateModified":"2025-11-17T11:43:14","FileList":["cp068638.xml","cpqsetup.exe","GPM1645ASAD5.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"fa6b82bce6ebc0856e4a26ed25859ff1","Name":"cp068638.exe","Release":"2025-11-17T11:37:59","Revision":"D","SHA1Sum":"b131f072e1418aecdca2ade8cfe75d27a422ce74","SHA256Sum":"863210e5ac6f4761322dce27b70e425e4a7ad009cf478737edf21f2c6348b71b","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO006400JWZJT","TargetGUID":"562340a5-304f-3630-3430-304a575a4a54","Type":"sas"},{"Id":"VO003200JWZJR","TargetGUID":"562340a5-304f-3330-3230-304a575a4a52","Type":"sas"},{"Id":"VO001600JWZJQ","TargetGUID":"562340a5-304f-3130-3630-304a575a4a51","Type":"sas"},{"Id":"VO000800JWZJP","TargetGUID":"562340a5-304f-3030-3830-304a575a4a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:03:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b0168ec5461d4a2c884ee180bec67bfa"}]},{"ProductId":"ae86717eaef841a7919ea42f85ca3fe7","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This driver, MegaSAS35, provides Windows 2025 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers"},{"Lang":"ja","Value":"このドライバー、MegaSAS35は、HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a Gen10p コントローラーおよびMR416i-o、MR416i-p、MR216i-o、MR216i-p、MR408i-o、MR408i-p Gen11コントローラー用のWindows 2025 64ビットのサポートを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"936224","DateModified":"2025-12-02T07:03:14","FileList":["cp069946.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","megasas35.inf","megasas35.pdb","megasas35.RttMeta","megasas35.sys","nodev.inf"],"MD5Sum":"87f19fd257a92561f33aefe8eaa516e6","Name":"cp069946.exe","Release":"2025-12-02T07:01:06","Revision":"C","SHA1Sum":"9c04ed19740b42de29a7841b0a1074b3f7adc9f1","SHA256Sum":"379b12cba994e6c0b981de6c26bd87e54b9d2e2c6e925ae4258d05fad02b245e","Size":"914KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.732.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>"},{"Lang":"ja","Value":"<p>ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2025 edition"},{"Lang":"ja","Value":"HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a Gen10pコントローラーおよびMR416i-o、MR416i-p、MR216i-o、MR216i-p、MR408i-o 、MR408i-p Gen11コントローラードライバーfor Microsoft Windows 2025 edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1440"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-01T03:10:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that system may crash when importing Logical Drive.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>論理ドライブをインポートするときにシステムがクラッシュする可能性がある問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that system may crash when importing Logical Drive.</li></ul>","Lang":"cn"}],"Version":"7.732.3.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated component metadata.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated component metadata.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated component metadata.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.732.3.0"}],"SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3b0289c763344f37a5968a9b1d057b40"}]},{"ProductId":"86420e4b9b414e61bd5c2f06d883ac98","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB002000JYDNE and MB004000JYDPB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB002000JYDNEおよびMB004000JYDPB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000JYDNE and MB004000JYDPB Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000JYDNE and MB004000JYDPB Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20608948","DateModified":"2025-06-23T12:56:55","FileList":["/CP067621_BUILD_1.data","/CP067621.vmexe64","/CP067621.vmfile","/CP067621_VMw.zip","/CP067621.xml","/payload.json","/CP067621_VMw.zip/index.xml","/CP067621_VMw.zip/vendor-index.xml","/CP067621_VMw.zip/metadata.zip","/CP067621_VMw.zip/vib20/CP067621/HPE_bootbank_CP067621_HPD6.1-8.0.0.20613240.vib","/CP067621_VMw.zip/metadata.zip/vendor-index.xml","/CP067621_VMw.zip/metadata.zip/vmware.xml","/CP067621_VMw.zip/metadata.zip/vibs/CP067621-8161956528259886615.xml","/CP067621_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067621_HPD6.1-8.0.0.20613240.xml"],"MD5Sum":"08490516d65090e7c48b7303c701acde","Name":"CP067621.zip","Release":"2025-06-23T12:56:04","Revision":"B","SHA1Sum":"e53fefdb27d357874e97a95dd0a2c9c798fb9746","SHA256Sum":"cb1ffa29b56f452ff4bd60327b07f2002fcc350938a0bfa6b4c185caf6105640","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP067621","Version":"HPD6.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br /><br />     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>)：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>     リモートオンライン：</strong></p><ul><li>適切なSPPをダウンロードします。</li><li>SPPにコンポーネントを追加します。</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li><li>SUMを実行します。</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li><li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p>詳細については、SPPのドキュメントを参照してください。 <a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p> </p><p><strong>ターゲットサーバー上のVMware ESXi 8.0/9.0オペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>rootとしてログインします。（アップデートを適用するには、rootユーザーである必要があります。）</li><li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li><li>CPXXXXXX.zipファイルをunzipします</li><li>vibファイルのインストール: esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip</li><li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用して、パス“/opt/Smart_Component/CPxxxxxx” : ./Execute_Componentからバイナリを実行します。</li></ul><p><フルパス>は、解凍されたzipファイル(CPxxxxxx.zip)の絶対的な一時ディレクトリパスです。</p><p><u>VIBファイルを削除するには。</u></p><ul><li>esxcli software component remove –n Smart-Component-CPxxxxxx</li><li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JYDNE and MB004000JYDPB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB002000JYDNEおよびMB004000JYDPBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000JYDPB","TargetGUID":"4d2340a5-3042-3430-3030-304a59445042","Type":"sas"},{"Id":"MB002000JYDNE","TargetGUID":"4d2340a5-3042-3230-3030-304a59444e45","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-19T14:52:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for future FIPS code release and one assert fix.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"193f7117b10a47e49ed790009419bd5a"}]},{"ProductId":"6adb26c5fc564f219877ab6a448e709b","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4_OCP_4p90_NCSIwPLDMoMCTP_80020EF3.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-15938086000c","Version":"4.90"}]},"MinimumActiveVersion":"4.20","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA4 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28&nbsp;OCP3</td><td>80020EF3</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 OCP3</td><td>80020EF3</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.9と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28&nbsp;OCP3</td><td>80020EF3</td><td>1.3863.0</td><td>4.90</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.9</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>"}],"Files":[{"Bytes":"10526649","DateModified":"2025-12-18T07:23:45","FileList":["HPE_E810_XXV4_OCP_4p90_NCSIwPLDMoMCTP_80020EF3.HPb","HPE_E810_XXV4_OCP_4p90_NCSIwPLDMoMCTP_80020EF3.xml","payload.json"],"MD5Sum":"9db03aef30762e2f2446b7b05a951459","Name":"HPE_E810_XXV4_OCP_4p90_NCSIwPLDMoMCTP_80020EF3.fwpkg","Release":"2025-12-18T07:20:30","Revision":"B","SHA1Sum":"519834495a9b5b09c6ffb08949f08940fac67654","SHA256Sum":"2eb1f7fcbdd1817d111de64ca461040caa69c0897e4eb04483fbe4a943d59db8","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000c"],"TypeOfChange":"1","Version":"4.90"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 OCP3アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-18T06:15:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"},{"ReleaseNotes":[{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、HPE RBSUメニューのNIC構成に起動時の自動リンクオプションを追加します。</p>","Fixes":"<ul><li>この製品は、HPE ProLiant Gen11 AMDプラットフォームサーバーでMSセキュアコアが有効になっている場合に PXE ブートが機能しない問題を修正しました。</li><li>この製品では、HPE RBSUメニューのNIC構成のリンク速度の選択が修正されました。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"<p>This product adds Automatic Link on Startup option under the NIC Configuration in HPE RBSU menu.</p>","Fixes":"<ul><li>This product fixed PXE Boot does not work when MS secured-core enabled with HPE ProLiant Gen11 AMD platform server.</li><li>This product fixed Link Speed selection under NIC Configuration in HPE RBSU menu.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"4.90"}],"SWKeys":[{"Name":"INTEL_E810_XXV4OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"f8c90151580642298741257c8630f8bd"}]},{"ProductId":"f64fce49b8774319b4cc4ce2ecc3d153","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4094548","DateModified":"2025-08-02T21:56:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-1.1/CP067382.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-1.1/TATCATSATAG1.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067382.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067382.scexe"],"MD5Sum":"f3db4f488b99415a32184f27d47d5f32","Name":"firmware-hdd-d39e7a7e75_0HPG1-1.1_amd64.deb","Release":"2025-08-03T02:46:01","Revision":"","SHA1Sum":"29f2fd2dd8fb7058b72f65f11d096d45b5849a94","SHA256Sum":"51291a2a21e24efb5d17785a91bfc156ef3e09d9033f1518eb5189aafb130e73","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040351.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000GWFWB","TargetGUID":"4d2340a5-3042-3430-3030-304757465742","Type":"sata"},{"Id":"MB002000GWFWA","TargetGUID":"4d2340a5-3042-3230-3030-304757465741","Type":"sata"},{"Id":"MB001000GWJAN","TargetGUID":"4d2340a5-3042-3130-3030-3047574a414e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:16:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>A minor reliability enhancement involving an extra head cleaning operation</li><li>Preventive corner-case and situational adjustments for a potential Read hang, rare weak read and some &ldquo;housekeeping&rdquo; items (display, command outputs, delay on power-up and log maintenance)</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>A minor reliability enhancement involving an extra head cleaning operation</li><li>Preventive corner-case and situational adjustments for a potential Read hang, rare weak read and some &ldquo;housekeeping&rdquo; items (display, command outputs, delay on power-up and log maintenance)</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>A minor reliability enhancement involving an extra head cleaning operation</li><li>Preventive corner-case and situational adjustments for a potential Read hang, rare weak read and some &ldquo;housekeeping&rdquo; items (display, command outputs, delay on power-up and log maintenance)</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f0b4b9b2a02445ff8c61915de1c7c17e"}]},{"ProductId":"d473378e1f2847f48383c6be4c105511","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"Integrated Smart Update Tools 6.5.0 for ESXi 8.0, ESXi 9.0 and ESXi 9.1"},{"Lang":"ja","Value":"Integrated Smart Update Tools 6.5.0 for ESXi 8.0およびESXi 9.1"},{"Lang":"cn","Value":"Integrated Smart Update Tools 6.5.0 for ESXi 8.0, ESXi 9.0 and ESXi 9.1"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"6029199","DateModified":"2026-01-21T03:42:27","FileList":["/cp069949.xml","/sutComponent_800.6.5.0.3-0-signed_component.zip","/sutComponent_800.6.5.0.3-0-signed_component.zip/index.xml","/sutComponent_800.6.5.0.3-0-signed_component.zip/vendor-index.xml","/sutComponent_800.6.5.0.3-0-signed_component.zip/metadata.zip","/sutComponent_800.6.5.0.3-0-signed_component.zip/vib20/sut/HPE_bootbank_sut_800.6.5.0.3-1OEM.802.0.0.22380479.vib","/sutComponent_800.6.5.0.3-0-signed_component.zip/metadata.zip/vendor-index.xml","/sutComponent_800.6.5.0.3-0-signed_component.zip/metadata.zip/vmware.xml","/sutComponent_800.6.5.0.3-0-signed_component.zip/metadata.zip/vibs/sut-2076985407541851110.xml","/sutComponent_800.6.5.0.3-0-signed_component.zip/metadata.zip/bulletins/sutComponent_800.6.5.0.3-0.xml","/sutComponent_800.6.5.0.3-0-signed_component.zip/metadata.zip/configSchemas/sut-800.6.5.0.3-1OEM.802.0.0.22380479-schema.json"],"MD5Sum":"828ca3d01ca464528af0dcd13d534bc5","Name":"cp069949.zip","Release":"2026-01-21T03:41:52","Revision":"","SHA1Sum":"69c4a14cf7ebcffbbff1a9c31a603be4a354fa66","SHA256Sum":"89eb649e06caa9564a52a315f2bc076a81c7ea18b4d3bdef03366138dfccb8ee","Size":"5MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.2"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf4d60f54"],"TypeOfChange":"1","Version":"2026.01.00","VibList":[{"Name":"sut","Version":"800.6.5.0.3-1OEM.802.0.0.22380479"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":150,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HPE Smart Update Manager (SUM) from the HPE Service Pack for ProLiant (SPP):</strong></p><ol><li>Place the SPP on a USB key using the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>.</li><li>Copy&nbsp;this component&nbsp;to the directory<em>&nbsp;/SPP20xxxxx/packages</em>&nbsp;on the USB key.</li><li>Mount the USB key on a remote server running Windows or Linux.</li><li>Change directories to&nbsp;<em>/packages</em>&nbsp;and execute ./smartupdate.bat or ./smartupdate.</li><li>Select the &quot;next&quot; button.</li><li>Click &quot;Add Single Target.&quot;</li><li>Enter&nbsp;the IP or DNS address of the iLO of the ESXi host to be updated.</li><li>Enter the iLO credentials (root or administrator username and password).</li><li>Follow Smart Update Manager&nbsp;instructions&nbsp;to complete the Component update.</li></ol><p>This&nbsp;method works if this component is already installed on the ESXi host and is running in the Auto mode.</p><p>Refer&nbsp;Server updates through iLO 5 in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00112955en_us&amp;docLocale=en_US&amp;page=index.html\">SUM User Guide</a></p><p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the component bundle.</li><li>Run the &quot;esxcli software component apply&quot; command&nbsp;to install the component bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiant (SPP)からHPE Smart Update Manager（SUM）を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p><ol><li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li><li>このコンポーネントをUSBキーの<em>/SPP20xxxxx/packages</em>ディレクトリにコピーします。</li><li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li><li>ディレクトリを<em>/packages</em>に変更し、./smartupdate.batまたは./smartupdateを実行します。</li><li>「次へ」ボタンを選択します。</li><li>「シングルターゲットの追加」をクリックします。</li><li>アップデート対象のESXiホストのiLOのIPまたはDNSアドレスを入力します。</li><li>iLO認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li><li>Smart Update Managerの手順に従って、コンポーネントのアップデートを完了します。</li></ol><p>この方法は、このコンポーネントがすでにESXiホストにインストールされていて、自動モードで実行されている場合に機能します。</p><p>『<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00112955en_us&docLocale=en_US&page=index.html\">SUMユーザーガイド</a>』でiLO 5によるサーバーのアップデートを参照してください。</p><p><strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p><ol><li>コンポーネントバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li><li>コンポーネントバンドルをインストールするには、\"esxcli software component apply\"コマンドを実行します。</li></ol><p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HPE Smart Update Manager (SUM) from the HPE Service Pack for ProLiant (SPP):</strong></p><ol><li>Place the SPP on a USB key using the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>.</li><li>Copy&nbsp;this component&nbsp;to the directory<em>&nbsp;/SPP20xxxxx/packages</em>&nbsp;on the USB key.</li><li>Mount the USB key on a remote server running Windows or Linux.</li><li>Change directories to&nbsp;<em>/packages</em>&nbsp;and execute ./smartupdate.bat or ./smartupdate.</li><li>Select the &quot;next&quot; button.</li><li>Click &quot;Add Single Target.&quot;</li><li>Enter&nbsp;the IP or DNS address of the iLO of the ESXi host to be updated.</li><li>Enter the iLO credentials (root or administrator username and password).</li><li>Follow Smart Update Manager&nbsp;instructions&nbsp;to complete the Component update.</li></ol><p>This&nbsp;method works if this component is already installed on the ESXi host and is running in the Auto mode.</p><p>Refer&nbsp;Server updates through iLO 5 in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00112955en_us&amp;docLocale=en_US&amp;page=index.html\">SUM User Guide</a></p><p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the component bundle.</li><li>Run the &quot;esxcli software component apply&quot; command&nbsp;to install the component bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Integrated Smart Update Tools 6.5.0 for ESXi 8.0, ESXi 9.0 and ESXi 9.1"},{"Lang":"ja","Value":"Integrated Smart Update Tools 6.5.0 for ESXi 8.0およびESXi 9.1"},{"Lang":"cn","Value":"Integrated Smart Update Tools 6.5.0 for ESXi 8.0, ESXi 9.0 and ESXi 9.1"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"1","Name":"VMware ESXi 9.1","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-01T09:37:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>See the <a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes</a> for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>See the <a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes</a> for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"2025.11.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>See the <a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes</a> for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>See the <a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes</a> for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"2026.01.00"}],"SWKeys":[{"Name":"sutComponent:800.6.5.0.3-0","SWKeyExpectedPath":"software.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HP Smart Update Tools (HP SUT)"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"R13","Model":"HPE ProLiant Compute DL384 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b59552af1ed24caf932c71cc0bb22908"}]},{"ProductId":"14652a1a392747089da4a4254064ac9d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A41_3.70_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.70 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33598552","DateModified":"2026-01-14T07:53:50","FileList":["A41_3.70_01_09_2026.signed.flash","A41_3.70_01_09_2026.xml","payload.json"],"MD5Sum":"14c8aaf535a3488c2f40c0271615f928","Name":"A41_3.70_01_09_2026.fwpkg","Release":"2026-01-14T07:50:34","Revision":"","SHA1Sum":"e59a27c22b5a3dba418c735038092df70a53562d","SHA256Sum":"ec4c210aac8b8e7e4c328ee4a7bfbb147a741694d1bf9ca1885d827d0a85e990","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"1","Version":"3.70_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL325 Gen10 (A41) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL325 Gen10（A41）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL325 Gen10 (A41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T10:25:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>CVE-2025-3052を軽減するために、デフォルトのセキュアブートDBXをアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。システムROMのこのリビジョンには、AMD第1世代EPYCプロセッサー用のAMDリファレンスコードNaplesPI 1.0.0.Rが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Redfish経由でのBIOS設定の変更が、同じ起動中にBIOSアップデートが実行された場合に、失敗するという問題に対処しました。</p><p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_09-05-2025"},{"ReleaseNotes":[{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.70_01-09-2026"}],"SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"07df407c09e24197baa1773dc88641a5"}]},{"ProductId":"ff242e39c275472185612592300114ce","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for the HPE QLogic FastLinQ 10/25/50 GbE Server Adapters for Microsoft Windows Server 2022 and Microsoft Windows Server 2025."},{"Lang":"cn","Value":"This Component Package contains the drivers for the HPE QLogic FastLinQ 10/25/50 GbE Server Adapters for Microsoft Windows Server 2022 and Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージは、HPE QLogic FastLinQ 10/25/50 GbEサーバーアダプタードライバーfor Microsoft Windows Server 2022およびMicrosoft Windows Server 2025を含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This component contains the following drivers:</p><ul><li>Marvell Windows FastLinQ Ethernet VBD, 8.72.21.0</li><li>Marvell Windows FastLinQ Ethernet VBD Client, 8.72.21.0&nbsp;</li><li>Marvell Windows FCoE Offload Driver, 8.70.3.0</li><li>Marvell Windows FCoE Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Offload Driver, 8.70.2.0</li></ul>"},{"Lang":"ja","Value":"<p>このコンポーネントは、以下のドライバーを含みます。</p><ul><li>Marvell Windows FastLinQイーサーネットVBD、8.72.21.0</li><li>Marvell Windows FastLinQイーサーネットVBDクライアント、8.72.21.0 </li><li>Marvell Windows FCoEオフロードドライバー、8.70.3.0</li><li>Marvell Windows FCoEクラッシュダンプドライバー、8.58.2.0</li><li>Marvell Windows iSCSIクラッシュダンプドライバー、8.58.2.0</li><li>Marvell Windows iSCSIオフロードドライバー、8.70.2.0</li></ul>"},{"Lang":"cn","Value":"<p>This component contains the following drivers:</p><ul><li>Marvell Windows FastLinQ Ethernet VBD, 8.72.21.0</li><li>Marvell Windows FastLinQ Ethernet VBD Client, 8.72.21.0&nbsp;</li><li>Marvell Windows FCoE Offload Driver, 8.70.3.0</li><li>Marvell Windows FCoE Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Offload Driver, 8.70.2.0</li></ul>"}],"Files":[{"Bytes":"3576128","DateModified":"2025-11-14T04:24:20","FileList":["cp069566.xml","cpqsetup.exe","cp_data.xml","install.xml","qefcdo.sys","qefcdo_release.txt","qefcoe.cat","qefcoe.inf","qefcoe.sys","qefcoeco.dll","qefcoe_release.txt","qeiscdo.sys","qeiscdo_release.txt","qend.cat","qend.inf","qend.man","qenda.sys","qeois.cat","qeois.inf","qeois.sys","qeoisco.dll","qeois_release.txt","qevbd.cat","qevbd.inf","qevbda.sys","QLInstaller.dll","slipstream.zip"],"MD5Sum":"c67d9245f6ab222f0b61a1d09d549190","Name":"cp069566.exe","Release":"2025-11-14T04:09:03","Revision":"D","SHA1Sum":"cdac6f896d70ceff4ebf7a247351a78c2bbbb644","SHA256Sum":"08e077a81acaef192ffd75e7b9a6d7d4f9aa39ac77c4103e0d0a54f6ad188e71","Size":"3MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"TypeOfChange":"1","Version":"8.72.21.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"Lang":"ja","Value":"Windows Server x64 Edition用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002bd","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002bf","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002be","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002c0","Type":"pci","Ven":"1077"},{"Dev":"8080","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80801590021f","Type":"pci","Ven":"1077"},{"Dev":"8084","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80841590021f","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-809015900220","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021d","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021f","Type":"pci","Ven":"1077"},{"Dev":"8080","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80801590021a","Type":"pci","Ven":"1077"},{"Dev":"8080","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80801590021b","Type":"pci","Ven":"1077"},{"Dev":"8084","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80841590021a","Type":"pci","Ven":"1077"},{"Dev":"8084","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80841590021b","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021a","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T09:16:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Add Azure&nbsp;support.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Azure サポートを追加します。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Add Azure&nbsp;support.</p>","Fixes":"","Lang":"cn"}],"Version":"8.72.21.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Local 24H2 をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"cn"}],"Version":"8.72.21.0"}],"SWKeys":[{"Name":"qevbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"9a4d9987d9a0415894252fe50a4aec38"}]},{"ProductId":"81500ed23ae94776ba24fd962d1f8bd1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor."},{"Lang":"ja","Value":"このコンポーネントは、プロセッサー内のデバイスを識別するためのドライブなしのINFをインストールします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"624264","DateModified":"2025-11-18T08:31:15","FileList":["cp069740.xml","cpqsetup.exe","installer.dll","pnp/","pnp/AMDCCP.cat","pnp/AMDCCP.inf","pnp/AMDPCIDev.cat","pnp/AMDPCIDev.inf","pnp/amdpsp.cat","pnp/amdpsp.inf","pnp/SMBUSamd.cat","pnp/SMBUSamd.inf"],"MD5Sum":"d99163450b6dfc24f4812bb7bc450d18","Name":"cp069740.exe","Release":"2025-11-18T08:29:26","Revision":"B","SHA1Sum":"0c3ee166fffefdeef1073cc5c38da9315357e8b7","SHA256Sum":"1320fb74b18da06d12407c0cc4490d0e741d89eb1bddab7665c6218eafdbd811","Size":"609KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"1","Version":"6.4.8.206"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows"},{"Lang":"ja","Value":"Microsoft Windows用AMD EPYC プロセッサー（第3世代）識別子"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-18T08:26:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.4.8.206"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.4.8.206"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a7f6946f7005432493ab559114fd7ba5"}]},{"ProductId":"c19eee3c7a1046a4aeaff35e462fce56","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MM2000GEFRA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM2000GEFRA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19268026","DateModified":"2025-03-06T05:49:38","FileList":["/CP066001_BUILD_4.data","/CP066001.vmexe64","/CP066001.vmfile","/CP066001_VMw.zip","/CP066001.xml","/payload.json","/CP066001_VMw.zip/index.xml","/CP066001_VMw.zip/vendor-index.xml","/CP066001_VMw.zip/metadata.zip","/CP066001_VMw.zip/vib20/CP066001/HPE_bootbank_CP066001_HPG9.4-1OEM.800.1.0.20613240.vib","/CP066001_VMw.zip/metadata.zip/vendor-index.xml","/CP066001_VMw.zip/metadata.zip/vmware.xml","/CP066001_VMw.zip/metadata.zip/vibs/CP066001--7218200217336899870.xml","/CP066001_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066001_HPG9.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"abe72ced5c923a4b757e10750df2192d","Name":"CP066001.zip","Release":"2025-03-06T05:48:52","Revision":"E","SHA1Sum":"5b91b5533419833250abd88f2487b550ca7bd866","SHA256Sum":"d834932ff51f4036b9704c3fccefcff6fde525327f922bf2e074ea81f93cddc1","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-4d00-324d-3030-304745465241"],"TypeOfChange":"1","Version":"HPG9","VibList":[{"Name":"CP066001","Version":"HPG9.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040658.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MM2000GEFRA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MM2000GEFRAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MM2000GEFRA","TargetGUID":"002340a5-4d00-324d-3030-304745465241","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:59:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG9"}],"SWKeys":[{"Name":"MM2000GEFRA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"082b90a7fe714b2dba1a8cee129c9946"}]},{"ProductId":"8bf9eb4134cf48c2a7da72633124722f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1546952","DateModified":"2025-11-16T13:19:15","FileList":["cp069529.xml","cpqsetup.exe","cp_data.xml","i40eb.cat","i40eb.inf","i40eb.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"4757475b28a939881cea92450fc92e38","Name":"cp069529.exe","Release":"2025-11-16T13:04:40","Revision":"B","SHA1Sum":"8601db4a23e4d7ba1e54f7fa5ac0aff9205bde7d","SHA256Sum":"490915c78058adc0c205c432d7b60e4195cde4a6f78b4ddca044ca564d9c8931","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"TypeOfChange":"1","Version":"1.22.86.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40eb Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Intel i40ebドライバー for Windows Server 2025"},{"Lang":"cn","Value":"HPE Intel i40eb Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:50:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"cn"}],"Version":"1.22.86.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"","Lang":"cn"}],"Version":"1.22.86.0"}],"SWKeys":[{"Name":"i40eb.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\i40eb.inf_amd64_e2860b19128ec940"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6d4716f3a3af4bed82474934d138ca08"}]},{"ProductId":"3ba9b83f17144198845124cbe477505f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000JXMTH and MB020000JXMTP"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000JXMTH and MB020000JXMTP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4615600","DateModified":"2025-08-02T20:50:07","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-1.1/CP067361.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-1.1/SLONGSPKESD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067361.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067361.scexe"],"MD5Sum":"5276fcfc9d15b7479809adb2284456c9","Name":"firmware-hdd-020fc874ad_0HPD3-1.1_amd64.deb","Release":"2025-08-03T01:44:08","Revision":"","SHA1Sum":"2289c17b0848c16957be7f5a0872b9388a943019","SHA256Sum":"45e097dd76b07ef159a6d4b1ab78d62d904293304af8065afcc29a20b5447b3d","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP041696.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MB018000JXMTH and MB020000JXMTP Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MB018000JXMTH and MB020000JXMTP Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB020000JXMTP","TargetGUID":"4d2340a5-3042-3032-3030-304a584d5450","Type":"sas"},{"Id":"MB018000JXMTH","TargetGUID":"4d2340a5-3042-3831-3030-304a584d5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T13:00:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5669ee719471471891e8aca62d3fb9ca"}]},{"ProductId":"d6810024a18142b0a4b8ec4db68a4e55","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3690308","DateModified":"2025-12-11T08:11:39","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1/CP070006.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-17.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070006.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070006.scexe"],"MD5Sum":"17b5faba0b353e1c4bfe10afc8761a58","Name":"firmware-d3000-5.04-17.1.x86_64.rpm","Release":"2025-12-11T14:02:48","Revision":"Q","SHA1Sum":"cf3058ad307f76d9ba0fd4910422766b1506af5f","SHA256Sum":"d598388a714e570121da7493f9dd676a0baecc383cefcaeba5aa84f2db0a1895","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"Installation":{"Command":"setup","CommandParams":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"cn","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"ja","Value":"Linux (x64)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3600","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Type":"sas"},{"Id":"D3610","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3700","TargetGUID":"b99dfb74-f0bc-464f-b418-cd186af467e1","Type":"sas"},{"Id":"D3710","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-09T10:00:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Rhel 7.8のサポートを追加 </p></li><li><p>Rhel 8.2のサポートを追加 </p></li><li><p>SLES15 SP2のサポートを追加しました。</p></li></ul>","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li><p>Enabled-ClusterS2Dコマンドは、NonStopソリューションのD3610ディスクエンクロージャー内のSATAドライブ上で実行すると正常に完了するようになりました。</p></li><li><p>SASドライブのドライブケースであるスマートキャリアは、D3610/D3710ドライブエンクロージャーで認証されるようになりました。</p></li><li><p>ファンモジュールAおよびBの問題を報告するために、新しい7セグメントエラーコードE0およびE1がそれぞれ追加されました。これらの新しいコードはD3610/D3710にのみ適用され、ファームウェア5.04を実行しているときにのみ表示されます。</p></li><li><p>I/Oモジュール内のストレージエンクロージャープロセッサーに障害が発生すると、プロセッサーを確実にオンラインに戻すために、ハードリセット（電源を切ってから電源を入れる）が実行されます。</p></li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support of RHEL 9.1</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>RHEL 8.7のサポートを追加</p></li><li><p>RHEL 9.1のサポートを追加</p></li><li><p>SLES15 SP4のサポートを追加</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support of RHEL 9.1</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"}],"SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ce8bc463b8c3413c9f7ff97743f96b92"}]},{"ProductId":"228e6aefb0ce46a0a7e230319e326d29","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"cn","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"ja","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1734480","DateModified":"2026-01-05T06:23:21","FileList":["cp066321.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"MD5Sum":"613296eebf0ab30093e9002c7d2d9ce5","Name":"cp066321.exe","Release":"2026-01-05T06:21:30","Revision":"b","SHA1Sum":"282228809d80307ebf7712a3a040e84ce2873766","SHA256Sum":"8890eb3477873362c589c535e3de4c8fc09719aab83c343eab60e7e0a7b0218d","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />［インストール］ボタンをクリックして、インストールを開始します。<br />"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 QLogic Storportドライバーfor Microsoft Windows Server 2016"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T14:55:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.11.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"}],"SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"44cda149e93b48f6aaf0b99ce77c5d47"}]},{"ProductId":"4899e6b54e3941a4b9c3090a539cf6db","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Controller"},{"Lang":"ja","Value":"ソフトウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"软件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID®製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Overview:</strong><br />==========<br />1. In ESXi8.0, Direct utility execution is not permitted because of mandatory security policy enforcement in ESXi 8.0.<br />2. ESXi8.0 mandates the usage of esxcli plugin for utilities. Hence esxcli plugins need to be created for all the corresponding StorCLI command set.&nbsp;</p><p>&nbsp;</p><p><strong>Existing command output/VIB behavior changes:</strong><br />==============================================<br />1. System reboot is required for changes to take effect post VIB installation. This is because of the esxcli plugin support. StorCLI namespace needs to be registered with esxcli and hence a system reboot is the mandatory step per VMware for changes to take effect.<br />2. If StorCLI utility is directly executed, Command output will be in XML format with XML encoded special characters in place.</p><p>&nbsp;</p><p><strong>Files access / permissions:</strong><br />============================<br />1. By default, CLI log file or any files, which are generated by plugin, will be created under /var/log/vmware/ directory.<br />2. An absolute file path needs to be provided for any plugins which take file as an input.</p><p>&nbsp;</p><p><strong>Limitations:</strong><br />=============<br />1. &nbsp;Memory and temp file reservation for storcli is restricted to 100MB in ESXi8.0. Hence if this memory / temp file reservation is exhausted, Plugin will not be able to parse the data correctly. Hence please make sure that the mentioned amount of memory is reserved.<br />2. &nbsp;Direct StorCLI utility command execution will yield a XML formatted output which aligns to XML rule set.<br />3. &nbsp;Command options / command / namespaces in ESXCLI plugin are case sensitive. Hence plugin should be executed based on the help mentioned for each of the esxcli plugin else esxcli plugin will error out.<br />4. &nbsp;ESXCLI plugin has a command output data limit. If this exceeds, Plugin will not parse and display the information. If the command output length is more, Please use the file option to store the data instead else please follow the below instructions from VMware to increase the data limit.</p><p>&nbsp;</p><p><strong>Steps to increase the command data limit:</strong><br />=========================================<br />1. Run the following command on the host in question: configstorecli config current get -c esx -g services -k hostd &gt; out.json<br />2. Try bumping the limits in the below in VMOMI adapter and see if it helps when running esxcli.</p><p>&nbsp; &nbsp; &nbsp; &quot;vmomi&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&quot;soap_request&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_elements&quot;: 500000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_depth&quot;: 1000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_unauthenticated_doc_size&quot;: 100000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_doc_size&quot;: 20000000<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;}<br />&nbsp; &nbsp; &nbsp; },<br />3. Then in the resulting out.json file find the entries above and bump the limits, e.g. double max_elements, max_depth and max_doc_size.<br />4. Finally, reapply:<br />&nbsp; &nbsp;configstorecli config current set -c esx -g services -k hostd -infile out.json<br />5. Reboot the server.</p><p>&nbsp;</p><p><strong>Additional notes:</strong><br />=================<br />1. For system namespace i.e., esxcli storcli system &lt;&gt;, except the esxcli storcli system file &lt;&gt; plugin, Options --json and --nolog are valid.&nbsp;<br />&nbsp; &nbsp;These options are not displayed in esxcli plugin help because these options are optional and there are no mandatory options for these set of commands.<br />2. The command options to the plugins are maintained in lower case as they are case sensitive. &nbsp;<br />3. The command options are presented in alphabetical order of the parameter name. It&#39;s per the esxcli plugin convention/rules.<br />4. Input value needs to be enclosed in double quotes if format of the value has a space.<br />5. Help command is not added as the esxcli plugin framework offers help based on the available namespaces and corresponding commands/command options can be queried accordingly.</p><p>&nbsp;</p><p><strong>ESXCLI Plugin format:</strong><br />======================</p><p>esxcli [options] {namespace}+ {cmd} [cmd options]</p><p>Example : esxcli storcli system show ctrlcount</p><p>&nbsp;</p><p><strong>ESXCLI plugin sample command output:</strong><br />=====================================<br />esxcli storcli system show ctrlcount<br />CLI Version = 007.2417.0000.0000 Apr 21, 2023<br />Operating system = VMkernel8.0.0<br />Status Code = 0<br />Status = Success<br />Description = None</p><p>Controller Count = 1</p>"},{"Lang":"ja","Value":"<p><strong>概要：</strong><br />==========<br />1. ESXi 8.0では、セキュリティポリシーの適用が必須であるため、ESXi 8.0でのユーティリティの直接実行は許可されません。<br />2. ESXi8.0では、ユーティリティにesxcliプラグインの使用が必須です。したがって、対応するすべてのStorCLIコマンドセットに対してesxcliプラグインを作成する必要があります。 </p><p> </p><p><strong>既存のコマンド出力/VIBの動作が次のように変更されます。</strong><br />==============================================<br />1. VIBのインストール後に変更を有効にするには、システムの再起動が必要です。これは、esxcliプラグインのサポートのためです。StorCLI名前空間はesxcliに登録する必要があるため、変更を有効にするためにVMwareに従ってシステムの再起動が必須の手順になります。<br />2. StorCLIユーティリティが直接実行される場合、コマンド出力はXMLエンコードされた特殊文字を含むXML形式になります。</p><p> </p><p><strong>ファイルアクセス/許可</strong><br />============================<br />1. デフォルトでは、CLIログファイルまたはプラグインによって生成されるその他のファイルは、/var/log/vmware/ディレクトリに作成されます。<br />2. ファイルを入力として受け取る任意のプラグインには、絶対ファイルパスを指定する必要があります。</p><p> </p><p><strong>制限事項：</strong><br />=============<br />1.  storcliのメモリと一時ファイルの予約は、ESXi8.0では100MBに制限されています。したがって、このメモリ/一時ファイルの予約が使い果たされると、プラグインはデータを正しく解析できなくなります。したがって、上記の量のメモリが予約されていることを確認してください。<br />2.  StorCLIユーティリティコマンドを直接実行すると、XMLルールセットに準拠したXML形式の出力が生成されます。<br />3.  ESXCLIプラグインのコマンドオプション/コマンド/名前空間では、大文字と小文字が区別されます。したがって、各esxcliプラグインについて説明されているヘルプに基づいてプラグインを実行する必要があります。そうしないと、esxcliプラグインがエラーになります。<br />4.  ESXCLIプラグインにはコマンド出力データ制限があります。これを超えると、プラグインは情報を解析して表示しません。コマンド出力の長さがそれより長い場合は、代わりにファイルオプションを使用してデータを保存してください。それ以外の場合は、VMwareからの以下の指示に従ってデータ制限を増やしてください。</p><p> </p><p><strong>コマンドデータ制限を増やす手順：</strong><br />=========================================<br />1. 問題のホストで次のコマンドを実行します：configstorecli config current get -c esx -g services -k hostd > out.json<br />2. VMOMIアダプターで以下の制限を上げようとしてみて、esxcliの実行時に役立つかどうかを確認します。</p><p>      \"vmomi\": {<br />         \"soap_request\": {<br />            \"max_elements\": 500000,<br />            \"max_depth\": 1000,<br />            \"max_unauthenticated_doc_size\": 100000,<br />            \"max_doc_size\": 20000000<br />         }<br />      },<br />3. 次に、結果のout.jsonファイルで上記のエントリーを見つけて、制限を上げます（例：max_elements、max_depth、およびmax_doc_sizeを倍にする）。<br />4. 最後に、再適用します。<br />   configstorecli config current set -c esx -g services -k hostd -infile out.json<br />5. サーバーを再起動します。</p><p> </p><p><strong>追加の注意：</strong><br />=================<br />1. システム名前空間の場合、つまりesxcli storcli system <>（esxcli storcli system file <>プラグインを除く）では、オプション--jsonおよび--nologが有効です。 <br />   これらのオプションはオプションであり、これらのコマンドセットには必須のオプションがないため、esxcliプラグインヘルプには表示されません。<br />2. プラグインのコマンドオプションは大文字と小文字が区別されるため、小文字で維持されます。 <br />3. コマンドオプションは、パラメーター名のアルファベット順に表示されます。これは、esxcliプラグインの表記規則/ルールに従っています。<br />4. 値の形式にスペースが含まれる場合、入力値を二重引用符で囲む必要があります。<br />5. esxcliプラグインフレームワークは使用可能な名前空間に基づいてヘルプを提供し、対応するコマンド/コマンドオプションはそれに応じてクエリできるため、ヘルプコマンドは追加されません。</p><p> </p><p><strong>ESXCLIプラグイン形式：</strong><br />======================</p><p>esxcli [options] {namespace}+ {cmd} [cmd options]</p><p>例：esxcli storcli system show ctrlcount</p><p> </p><p><strong>ESXCLIプラグインのサンプルコマンド出力：</strong><br />=====================================<br />esxcli storcli system show ctrlcount<br />CLI Version = 007.2417.0000.0000 Apr 21, 2023<br />Operating system = VMkernel8.0.0<br />Status Code = 0<br />Status = Success<br />Description = None</p><p>Controller Count = 1</p>"},{"Lang":"cn","Value":"<p><strong>Overview:</strong><br />==========<br />1. In ESXi8.0, Direct utility execution is not permitted because of mandatory security policy enforcement in ESXi 8.0.<br />2. ESXi8.0 mandates the usage of esxcli plugin for utilities. Hence esxcli plugins need to be created for all the corresponding StorCLI command set.&nbsp;</p><p>&nbsp;</p><p><strong>Existing command output/VIB behavior changes:</strong><br />==============================================<br />1. System reboot is required for changes to take effect post VIB installation. This is because of the esxcli plugin support. StorCLI namespace needs to be registered with esxcli and hence a system reboot is the mandatory step per VMware for changes to take effect.<br />2. If StorCLI utility is directly executed, Command output will be in XML format with XML encoded special characters in place.</p><p>&nbsp;</p><p><strong>Files access / permissions:</strong><br />============================<br />1. By default, CLI log file or any files, which are generated by plugin, will be created under /var/log/vmware/ directory.<br />2. An absolute file path needs to be provided for any plugins which take file as an input.</p><p>&nbsp;</p><p><strong>Limitations:</strong><br />=============<br />1. &nbsp;Memory and temp file reservation for storcli is restricted to 100MB in ESXi8.0. Hence if this memory / temp file reservation is exhausted, Plugin will not be able to parse the data correctly. Hence please make sure that the mentioned amount of memory is reserved.<br />2. &nbsp;Direct StorCLI utility command execution will yield a XML formatted output which aligns to XML rule set.<br />3. &nbsp;Command options / command / namespaces in ESXCLI plugin are case sensitive. Hence plugin should be executed based on the help mentioned for each of the esxcli plugin else esxcli plugin will error out.<br />4. &nbsp;ESXCLI plugin has a command output data limit. If this exceeds, Plugin will not parse and display the information. If the command output length is more, Please use the file option to store the data instead else please follow the below instructions from VMware to increase the data limit.</p><p>&nbsp;</p><p><strong>Steps to increase the command data limit:</strong><br />=========================================<br />1. Run the following command on the host in question: configstorecli config current get -c esx -g services -k hostd &gt; out.json<br />2. Try bumping the limits in the below in VMOMI adapter and see if it helps when running esxcli.</p><p>&nbsp; &nbsp; &nbsp; &quot;vmomi&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&quot;soap_request&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_elements&quot;: 500000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_depth&quot;: 1000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_unauthenticated_doc_size&quot;: 100000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_doc_size&quot;: 20000000<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;}<br />&nbsp; &nbsp; &nbsp; },<br />3. Then in the resulting out.json file find the entries above and bump the limits, e.g. double max_elements, max_depth and max_doc_size.<br />4. Finally, reapply:<br />&nbsp; &nbsp;configstorecli config current set -c esx -g services -k hostd -infile out.json<br />5. Reboot the server.</p><p>&nbsp;</p><p><strong>Additional notes:</strong><br />=================<br />1. For system namespace i.e., esxcli storcli system &lt;&gt;, except the esxcli storcli system file &lt;&gt; plugin, Options --json and --nolog are valid.&nbsp;<br />&nbsp; &nbsp;These options are not displayed in esxcli plugin help because these options are optional and there are no mandatory options for these set of commands.<br />2. The command options to the plugins are maintained in lower case as they are case sensitive. &nbsp;<br />3. The command options are presented in alphabetical order of the parameter name. It&#39;s per the esxcli plugin convention/rules.<br />4. Input value needs to be enclosed in double quotes if format of the value has a space.<br />5. Help command is not added as the esxcli plugin framework offers help based on the available namespaces and corresponding commands/command options can be queried accordingly.</p><p>&nbsp;</p><p><strong>ESXCLI Plugin format:</strong><br />======================</p><p>esxcli [options] {namespace}+ {cmd} [cmd options]</p><p>Example : esxcli storcli system show ctrlcount</p><p>&nbsp;</p><p><strong>ESXCLI plugin sample command output:</strong><br />=====================================<br />esxcli storcli system show ctrlcount<br />CLI Version = 007.2417.0000.0000 Apr 21, 2023<br />Operating system = VMkernel8.0.0<br />Status Code = 0<br />Status = Success<br />Description = None</p><p>Controller Count = 1</p>"}],"Files":[{"Bytes":"17026933","DateModified":"2025-08-19T09:55:14","FileList":["/BCM-storcli_007.3212.0000.0000-02.zip","/BCM_bootbank_storcli_007.3212.0000.0000-02.vib","/cp067756.xml","/BCM-storcli_007.3212.0000.0000-02.zip/index.xml","/BCM-storcli_007.3212.0000.0000-02.zip/vendor-index.xml","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip","/BCM-storcli_007.3212.0000.0000-02.zip/vib20/storcli/BCM_bootbank_storcli_007.3212.0000.0000-02.vib","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip/vibs/storcli--8585630826784091899.xml","/BCM-storcli_007.3212.0000.0000-02.zip/metadata.zip/bulletins/BCM-storcli_007.3212.0000.0000-02.xml"],"MD5Sum":"f1415fb14ef7ce923138f819941bb717","Name":"cp067756.zip","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"0d702ac3f871a029378653b8834a2f90f689b92b","SHA256Sum":"36428e6e3e42f004d0042f643b9bbb454c7da0b2c7fb0fec8cf54c993d3bb725","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2025.08.01","VibList":[{"Name":"storcli","Version":"007.3212.0000.0000-02"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Installing VIBs on the ESXi 8.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"},{"Lang":"ja","Value":"<p><strong>ESXiシェルからのESXi8.0ホストへのVIBのインストール：</strong></p><ul><li>ESXiホストのローカルパスへのVIBの転送</li><li>ESXiシェルで以下のesxcliコマンドを実行して、VIBをインストールします。</li><li><strong># esxcli software vib install -d <path><componet_bundle></strong><strong> </strong></li><li>署名なしバイナリの場合は、installコマンドで--no-sig-checkパラメーターを渡す必要があります</li><li><strong># esxcli software vib install -d <path><componet_bundle> --no-sig-check</strong></li></ul><p><strong>VIBパッケージは次のコマンドを使用して削除できます</strong></p><ul><li><strong># esxcli software vib remove -n <filename></strong></li><li>インストールされているvibファイル名をリストするには、<strong># esxcli software vib list | grep storcli</strong>コマンドを使用します</li></ul>"},{"Lang":"cn","Value":"<p><strong>Installing VIBs on the ESXi 8.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware8.0 (For Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware 8.0 (For Gen10 PlusおよびGen11コントローラー)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware8.0 (For Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T04:15:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加<ul><li>コマンド: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.08.01"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加<ul><li>コマンド: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.08.01"}],"SWKeys":[{"Name":"BCM-storcli:007.3212.0000.0000-02","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3212.0000.0000-02","SWKeyExpectedPath":"software:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1b1532f380e843678a34a72933eeb5ba"}]},{"ProductId":"1a121f2eb5274f1cbf1d67964da2e171","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"4765364","DateModified":"2025-08-02T21:01:23","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-1.1/CP067363.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-1.1/HVLAeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067363.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067363.scexe"],"MD5Sum":"36f18b2fdfeb680709cc83347bd3b71d","Name":"firmware-hdd-a886842a99_0HPD2-1.1_amd64.deb","Release":"2025-08-03T01:54:03","Revision":"","SHA1Sum":"7769ef2e9ab3f8f7c32610b1b134c00ba2cea1ac","SHA256Sum":"49494017fe56ac74c047a441434e52d236446b67cfa1ffacde2a0a14fd7fd7e0","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041488.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000JWKGN Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000JWKGN Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000JWKGN","TargetGUID":"4d2340a5-3042-3630-3030-304a574b474e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T13:01:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul>","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"45d9cb0364474ec8a10d37f378652d48"}]},{"ProductId":"e6b0d97326414c5688fb57aa0f288b70","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"4756700","DateModified":"2025-08-02T21:00:11","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-1.1/CP067364.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-1.1/HVLAnAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067364.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067364.scexe"],"MD5Sum":"b9e229912601f310f7adbe6c162ab7db","Name":"firmware-hdd-2c27a7a9a4_0HPD2-1.1_amd64.deb","Release":"2025-08-03T01:54:11","Revision":"","SHA1Sum":"779e02c3a5690b770c0befa7616d447780daede7","SHA256Sum":"5a27798fa12706f10bde3382ca1184121961142c5533377e0ace946902d836f1","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041491.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWKGU Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWKGU Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JWKGU","TargetGUID":"4d2340a5-3042-3430-3030-304a574b4755","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T13:02:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul>","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"69f16a9ad1444b70a92183053970b2e2"}]},{"ProductId":"2e4ac8b988164dc087668639a95037d3","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"ja","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 10."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"160148","DateModified":"2025-10-03T07:27:18","FileList":["./etc/depmod.d/tg3.conf","./lib/modules/6.12.0-55.11.1.el10_0.x86_64","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra/tg3","./lib/modules/6.12.0-55.11.1.el10_0.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/47","./usr/lib/.build-id/47/4f52a007fedcdfb0e96ddfe299c71250123c8a","./usr/share/smartupdate/kmod-tg3/component.xml"],"MD5Sum":"0a3274b6eee98f3624a6b81a4912817d","Name":"kmod-tg3-3.139w-1.rhel10u0.x86_64.rpm","Release":"2025-10-03T07:22:56","Revision":"","SHA1Sum":"e61398f65df31302f21e0e91ec017e59dd534b78","SHA256Sum":"6e5fa6e7f1f1058f54b8089708d854eefad3008cd2ef65c9062c38d34ec29b01","Size":"156KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.139w-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download README for installation notes.</p>"},{"Lang":"ja","Value":"<p>Download README for installation notes.</p>"},{"Lang":"cn","Value":"<p>Download README for installation notes.</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 10"},{"Lang":"ja","Value":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 10"},{"Lang":"cn","Value":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-03T06:23:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"3.139w-1"}],"SWKeys":[{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03030202","Model":"HPE Compute Scale-up Server 3250"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"946679b18e0a483397d4dc7e3773f91e"}]},{"ProductId":"a9e8e46bd6de460ea736a9be4499f26a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWRTD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"}],"Files":[{"Bytes":"20408387","DateModified":"2025-03-07T06:38:54","FileList":["/CP065989_BUILD_8.data","/CP065989.vmexe64","/CP065989.vmfile","/CP065989_VMw.zip","/CP065989.xml","/payload.json","/CP065989_VMw.zip/index.xml","/CP065989_VMw.zip/vendor-index.xml","/CP065989_VMw.zip/metadata.zip","/CP065989_VMw.zip/vib20/CP065989/HPE_bootbank_CP065989_HPD2.8-1OEM.800.1.0.20613240.vib","/CP065989_VMw.zip/metadata.zip/vendor-index.xml","/CP065989_VMw.zip/metadata.zip/vmware.xml","/CP065989_VMw.zip/metadata.zip/vibs/CP065989--774525207630488700.xml","/CP065989_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065989_HPD2.8-1OEM.800.1.0.20613240.xml"],"MD5Sum":"ea4a65538a4dd1dc4d27a709d773f3bf","Name":"CP065989.zip","Release":"2025-03-07T06:38:04","Revision":"G","SHA1Sum":"8f04bf6226081cc2a0a011a495e1dbd0e1a0dd8a","SHA256Sum":"ad8c041155f8a306855ccbca64497635c597c5b81b86a8df3341d69483e481b5","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP065989","Version":"HPD2.8-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041478.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWRTD ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000JWRTD","TargetGUID":"4d2340a5-3042-3830-3030-304a57525444","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:07:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"81d8c5b2beeb482ba3508dee74c64ae1"}]},{"ProductId":"5132cc00457040eca415ddc65a22d65e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improves performance in certain file systems and implements fixes for several of the previous firmware&rsquo;s shortcomings.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Improves performance in certain file systems and implements fixes for several of the previous firmware&rsquo;s shortcomings.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4622524","DateModified":"2025-08-02T22:47:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-1.1/CP067394.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-1.1/TAMG09scHPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067394.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067394.scexe"],"MD5Sum":"4fd01881432430f011184ed04ff23a29","Name":"firmware-hdd-87b796d9ae_0HPD4-1.1_amd64.deb","Release":"2025-08-03T03:41:57","Revision":"","SHA1Sum":"9932ae609daab911aba9cf12da6c76c7e8d6b8ac","SHA256Sum":"5052c08d8d855da9ab116b2d180071036c8e2c47f38f3437a255e172b164c4ad","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB012000JZYVN","TargetGUID":"4d2340a5-3042-3231-3030-304a5a59564e","Type":"sas"},{"Id":"MB014000JZYVP","TargetGUID":"4d2340a5-3042-3431-3030-304a5a595650","Type":"sas"},{"Id":"MB016000JZYVQ","TargetGUID":"4d2340a5-3042-3631-3030-304a5a595651","Type":"sas"},{"Id":"MB018000JYCLK","TargetGUID":"4d2340a5-3042-3831-3030-304a59434c4b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:39:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improves performance in certain file systems and implements fixes for several of the previous firmware&rsquo;s shortcomings.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Improves performance in certain file systems and implements fixes for several of the previous firmware&rsquo;s shortcomings.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improves performance in certain file systems and implements fixes for several of the previous firmware&rsquo;s shortcomings.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs.</li><li>Support firmware flash in OS FIPS enabled mode.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a310702b8e7e4d10be458d762d61b637"}]},{"ProductId":"c9a4232d8cb349049f544bcc6d02e97f","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR416i-a_Gen10P_52.32.3-6333_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.32.3-6333"}]},"MinimumActiveVersion":"52.26.3.5487","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"HPE MR416i-a Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"ja","Value":"<p>One-buttonセキュア消去（OBSE）およびオンラインファームウェアアクティベーション（OFA）はHPE Gen10サーバーではサポートされていないため、MR Gen10 plusコントローラーはGen10サーバーでのオンラインファームウェアアップデートをサポートしません。<br />HPE Gen10サーバーにFWPKGをインストールする必要がある場合は、FWPKGをフラッシュした後に再起動が必要になることを想定してください。</p>"},{"Lang":"cn","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"}],"Files":[{"Bytes":"7514170","DateModified":"2025-08-19T10:42:13","FileList":["HPE_MR416i-a_Gen10P_52.32.3-6333_A.HPb","HPE_MR416i-a_Gen10P_52.32.3-6333_A.xml","payload.json"],"MD5Sum":"682a7c2259ffdbab47efb0feecbabaed","Name":"HPE_MR416i-a_Gen10P_52.32.3-6333_A.fwpkg","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"d4e82ebde9aa11a22848d78b8966bbc8b012301b","SHA256Sum":"042fb1f40eb7898072b57a9c191ccb497348669cb7e3cbc6b39891a50f05941a","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032a"],"TypeOfChange":"1","Version":"52.32.3-6333"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a><a href=\"http://www.hpe.com/servers/resttool\">l</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/connect/s/product?language=en_US&kmpmoid=7630408&tab=driversAndSoftware&driversAndSoftwareFilter=8000078\">RESTfulインターフェイスツール</a><a href=\"http://www.hpe.com/servers/resttool\">l</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p><p>iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li></ul>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a><a href=\"http://www.hpe.com/servers/resttool\">l</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE MR416i-a Gen10 Plusトライモードコントローラー"},{"Lang":"cn","Value":"Firmware Package - HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T18:03:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfish デバイス有効化の機能強化<ul><li>Redfishボリューム変換サポート<ul><li>POST #Volume.ChangeRAIDLayout: RAIDレイアウトの変更。RAIDレイアウトの変更は、入力JSONボディにターゲットRAIDTypeとドライブのリストを提供することで実現されます。</li><li>POST #Volume.ChangeRAIDLayout: サイズ変更。ChangeRAIDLayoutを使用すると、RAIDTypeを変更せずに新しい未構成正常ドライブを追加することでボリュームのサイズを変更できます。このような場合、入力JSONボディでRAIDTypeを指定してはいけませんが、それに応じて完全なドライブリストを指定する必要があります。</li><li>PATCH Volume[CapacityBytes]: この操作は、ボリューム内に利用可能な未使用サイズがある場合にボリュームのサイズを変更するために使用されます。ここに新しいドライブを追加するスコープはありません</li><li>POST #Volume.CheckConsistency: この操作は、ボリューム上の整合性チェック操作を開始します。この操作では入力は想定されません。</li></ul></li><li>Redfish Metrics GETサポート<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount、CorrectableECCErrorCount、CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount、SAS.LossOfDwordSynchronizationCount、SAS.RunningDisparityErrorCount、PCIeErrors.CorrectableErrorCount、PCIeErrors.FatalErrorCount、PCIeErrors.NonFatalErrorCount</li><li>各カウンターは最大65535までの値を保持できます。カウンターが最大値に達しても、値はリセットされません。</li><li>ユーザーがコントローラーのNVRAMクリアまたはRedfish ResetToDefaults.ResetAllを実行すると、メトリックはクリアされます。</li></ul></li></ul></li><li>MRSAおよびstorcli工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加。<ul><li>コントローラー上に構成が存在する場合、または固定キャッシュが存在する場合、NVRAMクリア操作は許可されません。</li><li>NVRAMをクリアした後、コントローラーFWはオンラインコントローラーリセット (OCR) を実行します。何らかの理由でOCRを実行できない場合は、システムを再起動するようにユーザーに通知されます。</li><li>NVRAMクリア操作は、機能的にはRedfish ResetToDefaults.ResetAll操作と同等です。</li></ul></li><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。非ホットプラグ構成の場合、コントローラーは常に16個のベイを表示します。</li></ul>","Fixes":"<ul><li>a00143124en_usアドバイザリを修正: HPE MR Gen11 コントローラー - HPE Gen11サーバー上のMR Gen11コントローラーがIMLで\"WriteCacheDataLoss\"を生成できない場合がある</li><li>a00148035en_usアドバイザリを修正: HPE MR Gen11コントローラー - ベイとボックスのNVMeドライブの場所がワンタイムブートメニューに表示されない</li><li>Linux OSでLTOの128KBを超える読み取り/書き込み転送が失敗する問題を修正</li><li>Backup ExecがLTOで動作しない問題を修正</li><li>240個の論理ドライブが構成されている場合、サーバーのブート時にコントローラーがiLOによってドロップされる可能性がある問題を修正</li><li>ドライブを連続的に削除すると、サーバーヘルスが一時的にクリティカルを示すというまれな問題を修正</li><li>予期しないPCIConfiglinkページイベント、仮想SESデバイスへのタスク管理のタイムアウトメッセージがsnapdumpに記録される問題を修正</li><li>空のベイにスロット対応プロトコルがない問題を修正</li><li>コントローラーに接続されたLTOのリンク速度が[不明]と表示される問題を修正</li><li>Request Senseコマンドにより、サニタイズが進行中のドライブでタスク管理が実行される問題を修正。</li><li>255を超える値が使用された場合に、Redfish PATCH StorageController[ControllerRates]がランダムな値を暗黙的に設定してしまう問題を修正。</li><li>コントローラーがパススルーとして構成されているときにVMを再起動すると、誤ったコントローラーエラーイベントが記録される可能性がある問題を修正</li><li>2つのバックプレーンが同じストレージポートに接続されている場合、Redfishファブリックポートのアクティブ幅と現在の速度が間違っているという問題を修正。</li><li>再起動後にNVMeドライブのリンクステータスが失敗する可能性があるというまれな問題を修正 </li><li>複数のドライブの取り外しと挿入が短時間に行われたときにコントローラーがアサートされる可能性があるというまれな問題を修正</li><li>SATAパススルーコマンドが実行中の場合、SATAドライブのサニタイズのパーセンテージが進行しない問題を修正</li><li>NVMeドライブでサニタイズのパーセンテージが進行しない問題を修正</li><li>読み取り/書き込みコマンドと非読み取り/書き込みコマンドの耐久テストでIOタイムアウトとデバイスリセットが発生することがあるというまれな問題を修正</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"cn"}],"Version":"52.32.3-6333"},{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfish デバイス有効化の機能強化<ul><li>Redfishボリューム変換サポート<ul><li>POST #Volume.ChangeRAIDLayout: RAIDレイアウトの変更。RAIDレイアウトの変更は、入力JSONボディにターゲットRAIDTypeとドライブのリストを提供することで実現されます。</li><li>POST #Volume.ChangeRAIDLayout: サイズ変更。ChangeRAIDLayoutを使用すると、RAIDTypeを変更せずに新しい未構成正常ドライブを追加することでボリュームのサイズを変更できます。このような場合、入力JSONボディでRAIDTypeを指定してはいけませんが、それに応じて完全なドライブリストを指定する必要があります。</li><li>PATCH Volume[CapacityBytes]: この操作は、ボリューム内に利用可能な未使用サイズがある場合にボリュームのサイズを変更するために使用されます。ここに新しいドライブを追加するスコープはありません</li><li>POST #Volume.CheckConsistency: この操作は、ボリューム上の整合性チェック操作を開始します。この操作では入力は想定されません。</li></ul></li><li>Redfish Metrics GETサポート<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount、CorrectableECCErrorCount、CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount、SAS.LossOfDwordSynchronizationCount、SAS.RunningDisparityErrorCount、PCIeErrors.CorrectableErrorCount、PCIeErrors.FatalErrorCount、PCIeErrors.NonFatalErrorCount</li><li>各カウンターは最大65535までの値を保持できます。カウンターが最大値に達しても、値はリセットされません。</li><li>ユーザーがコントローラーのNVRAMクリアまたはRedfish ResetToDefaults.ResetAllを実行すると、メトリックはクリアされます。</li></ul></li></ul></li><li>MRSAおよびstorcli工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加。<ul><li>コントローラー上に構成が存在する場合、または固定キャッシュが存在する場合、NVRAMクリア操作は許可されません。</li><li>NVRAMをクリアした後、コントローラーFWはオンラインコントローラーリセット (OCR) を実行します。何らかの理由でOCRを実行できない場合は、システムを再起動するようにユーザーに通知されます。</li><li>NVRAMクリア操作は、機能的にはRedfish ResetToDefaults.ResetAll操作と同等です。</li></ul></li><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。非ホットプラグ構成の場合、コントローラーは常に16個のベイを表示します。</li></ul>","Fixes":"<ul><li>a00143124en_usアドバイザリを修正: HPE MR Gen11 コントローラー - HPE Gen11サーバー上のMR Gen11コントローラーがIMLで\"WriteCacheDataLoss\"を生成できない場合がある</li><li>a00148035en_usアドバイザリを修正: HPE MR Gen11コントローラー - ベイとボックスのNVMeドライブの場所がワンタイムブートメニューに表示されない</li><li>Linux OSでLTOの128KBを超える読み取り/書き込み転送が失敗する問題を修正</li><li>Backup ExecがLTOで動作しない問題を修正</li><li>240個の論理ドライブが構成されている場合、サーバーのブート時にコントローラーがiLOによってドロップされる可能性がある問題を修正</li><li>ドライブを連続的に削除すると、サーバーヘルスが一時的にクリティカルを示すというまれな問題を修正</li><li>予期しないPCIConfiglinkページイベント、仮想SESデバイスへのタスク管理のタイムアウトメッセージがsnapdumpに記録される問題を修正</li><li>空のベイにスロット対応プロトコルがない問題を修正</li><li>コントローラーに接続されたLTOのリンク速度が[不明]と表示される問題を修正</li><li>Request Senseコマンドにより、サニタイズが進行中のドライブでタスク管理が実行される問題を修正。</li><li>255を超える値が使用された場合に、Redfish PATCH StorageController[ControllerRates]がランダムな値を暗黙的に設定してしまう問題を修正。</li><li>コントローラーがパススルーとして構成されているときにVMを再起動すると、誤ったコントローラーエラーイベントが記録される可能性がある問題を修正</li><li>2つのバックプレーンが同じストレージポートに接続されている場合、Redfishファブリックポートのアクティブ幅と現在の速度が間違っているという問題を修正。</li><li>再起動後にNVMeドライブのリンクステータスが失敗する可能性があるというまれな問題を修正 </li><li>複数のドライブの取り外しと挿入が短時間に行われたときにコントローラーがアサートされる可能性があるというまれな問題を修正</li><li>SATAパススルーコマンドが実行中の場合、SATAドライブのサニタイズのパーセンテージが進行しない問題を修正</li><li>NVMeドライブでサニタイズのパーセンテージが進行しない問題を修正</li><li>読み取り/書き込みコマンドと非読み取り/書き込みコマンドの耐久テストでIOタイムアウトとデバイスリセットが発生することがあるというまれな問題を修正</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"cn"}],"Version":"52.32.3-6333"}],"SWKeys":[{"Name":"032A1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"fba646eb0ed94ee784241054f6c577c4"}]},{"ProductId":"5371b499023847d7b4f19c6fa659705b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"3108036","DateModified":"2025-08-03T00:06:26","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-1.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-1.1/CP067318.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067318.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067318.scexe"],"MD5Sum":"05cc5b471d9aa6c758c418b7b0d5eea8","Name":"firmware-hdd-aef2a690c9_0HPG5-1.1_amd64.deb","Release":"2025-08-03T04:57:46","Revision":"","SHA1Sum":"3da6c7ffe812c41d5e200476e7383b1563c8bbd0","SHA256Sum":"c6c96760d7b2a304384085d4ef2b8aa3f8653f2a196bd878eacbafde5caf9f20","Size":"2MB","TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"CP040776.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MK001920GWJPQ","TargetGUID":"4d2340a5-304b-3130-3932-3047574a5051","Type":"sata"},{"Id":"VK001920GWJPH","TargetGUID":"562340a5-304b-3130-3932-3047574a5048","Type":"sata"},{"Id":"MK000240GWKVK","TargetGUID":"4d2340a5-304b-3030-3234-3047574b564b","Type":"sata"},{"Id":"VK000240GWJPD","TargetGUID":"562340a5-304b-3030-3234-3047574a5044","Type":"sata"},{"Id":"VK003840GWJPK","TargetGUID":"562340a5-304b-3330-3834-3047574a504b","Type":"sata"},{"Id":"MK000480GWJPN","TargetGUID":"4d2340a5-304b-3030-3438-3047574a504e","Type":"sata"},{"Id":"VK000480GWJPE","TargetGUID":"562340a5-304b-3030-3438-3047574a5045","Type":"sata"},{"Id":"MK000960GWJPP","TargetGUID":"4d2340a5-304b-3030-3936-3047574a5050","Type":"sata"},{"Id":"VK000960GWJPF","TargetGUID":"562340a5-304b-3030-3936-3047574a5046","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:11:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul>","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c75a7285155344b9a4b0cf4c8a44eab7"}]},{"ProductId":"5ace706167bb418f8ac30077c43e3171","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.00"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.00"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.00"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.00"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.00"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.00"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.00.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"この x64 Smartコンポーネントは、次のストレージコントローラー用のファームウェアを提供します。 HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10 コントローラー"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>同じファームウェアバージョンの () 内のそのパッケージバージョンには、同じファームウェアバイナリイメージが含まれます。ユーザーは、同じファームウェアバージョンを再フラッシュする必要はありません。</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"7750536","DateModified":"2025-12-04T06:35:21","FileList":["cp069173.xml","cpqsetup.exe","HPE_luxor_8.00.bin.fw","payload.json","setup.dll"],"MD5Sum":"ff9aa83eaf0c6de4c34c2c5f8e272167","Name":"cp069173.exe","Release":"2026-02-02T00:00:00","Revision":"","SHA1Sum":"1baaa01feace6c90b166c408487ad9f894044055","SHA256Sum":"78ecc1d9d61c5da038b0b067aec893ba89b97f89fa7c1abeabe1f5d9095879c2","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.00"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>HPE Smart Update Managerを使用するには、</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>から以下の手順に従ってください:</strong></strong></p><ul><li>ディレクトリ\\SPP20xxxxx\\packagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows(x64) - HPE SmartアレイP408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10コントローラー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2026-03-03T07:52:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"cn"}],"Version":"8.00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Logical drive information menu: Enhanced to display the association between failed data drives and active spares upon drive failure.</li><li>&quot;Added support for the standardized Operation property in PLDM Operations arrays, providing schema-defined operation enums as below:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Drive Resource &mdash; Rebuild/Sanitize/Encrypt</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&ndash; Volume Resource &mdash; Initialize/Rebuild/Encrypt/ChangeRAIDLayout/ChangeStripSize/Resize.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The legacy OperationName property remains available and is now marked as deprecated.&quot;</p><ul><li>Added support for StorageController status conditions ResetRecommended and ResetRequired. When configuration changes require a system reboot to take effect, the controller reports the status through both Status.Conditions and Redfish event messages.</li><li>Enhanced RDE error messaging to provide clearer error descriptions for Volume DELETE and SED-enabled CREATE operations, returning detailed messages directly in the response payload instead of generic ExtendedInfo references.</li></ul>","Fixes":"<ul><li>Fixed an issue that prevented drive rebuilds from restarting after unexpected power loss when media exchange was accepted in auto-replace spare configurations.</li><li>Fixed an issue that caused auto-replace spare activation during the LOOSE_CABLE state, which could swap data drives prematurely and lead to volume failure and potential data integrity issues.</li><li>Fixed an issue where IOPS could drop on large-capacity HDDs during Consistency Check under 4K random write workloads in RAID 1 configurations.</li><li>Fixed an issue no-battery write cache (NBWC) can be enabled by the user in the event of a battery failure, unless the cache module itself is experiencing an error.</li><li>Fixed an issue where ATA passthrough IDENTIFY DEVICE (0xEC) commands issued from BMC could time out due to incorrect transfer length handling.</li><li>Fixed an issue where SSD array creation with non-deterministic drive ordering could incorrectly disable Acceralted IO on some drives, leading to performance degradation.</li><li>Fixed an issue where the fault LED did not illuminate for a hot-removed data drive during RAID rebuild with auto replace spare enabled.</li><li>Fixed an issue where the system could become unresponsive with lockup code as 0x1E00 when multiple out-of-band management requests were sent concurrently for the same session.</li><li>Fixed an issue where failed or missing drives were not correctly indicated when listing drives in the HII disk utilities menu.</li><li>Fixed an issue where PLDM Type 6 volume creation could fail on certain controllers that do not support volume caching or the IOPerfModeEnabled feature. Volume creation and update requests that explicitly disable these features (for example, setting cache policies to Off or IOPerfModeEnabled to false) are now handled correctly and will no longer be rejected.</li><li>Fixed an issue where RDE READ could incorrectly report a split mirror backup volume as Enabled instead of StandbyOffline when the original primary volume was created via RDE CREATE. Volume usage identification was corrected to ensure accurate status reporting.</li><li>Fixed an issue where DriveMetrics.PowerOnHours could be incorrectly reported as zero for SSDs on certain platforms. Power-on hours reporting was updated by drive type,&nbsp; NVMe drives reporting with DriveMetrics.NVMeSMART.PowerOnHours, SAS and SATA HDDs reporting a null value.</li></ul>","Lang":"cn"}],"Version":"8.00"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"7dd86b04242c48c98f185bf6b8bd76c1"}]},{"ProductId":"5413adceb7d241de900274e399d9c777","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているIntel i350 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1082352","DateModified":"2025-11-16T07:05:14","FileList":["cp069543.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"1c032fa62d0cc774a33947e2e535cd19","Name":"cp069543.exe","Release":"2025-11-16T06:50:30","Revision":"B","SHA1Sum":"e3e7158f66b761de3030515bda1e395d2eec726a","SHA256Sum":"aa058d4640fa160118c21c3decef95630c268cbc3195faddbbdbd91b78e38a49","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"TypeOfChange":"1","Version":"14.0.7.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i350 Driver for Windows Server 2019"},{"Lang":"ja","Value":"Intel i350ドライバー for Windows Server 2019"},{"Lang":"cn","Value":"Intel i350 Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"cn"}],"Version":"14.0.7.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization/SRIOV feature.</p>","Lang":"cn"}],"Version":"14.0.7.0"}],"SWKeys":[{"Name":"e1r68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4a14deaf10d5470da0e2b4e08f9da3ee"}]},{"ProductId":"683278c3722a411eb75e30e9eb4f543d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作するIntel Ethernet NIC用のiavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1418032","DateModified":"2025-11-16T05:17:17","FileList":["cp069546.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","manifest_iavf68.man","nicdrvr.dll"],"MD5Sum":"660ddd627fb79d47b67f0637834f5d6b","Name":"cp069546.exe","Release":"2025-11-16T05:02:33","Revision":"B","SHA1Sum":"90bd3d91e77c004e4ac1c2e45d8aaa02cc35106f","SHA256Sum":"6da64cbae1e57051a2d6deb08e5b058689a6550eaa4dca6c8afa38ce2108dc40","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"TypeOfChange":"1","Version":"1.17.63.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel iavf Driver for Windows Server 2019"},{"Lang":"ja","Value":"Intel iavfドライバーfor Windows Server 2019"},{"Lang":"cn","Value":"Intel iavf Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"}],"SWKeys":[{"Name":"iavf68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"34b4c250a802481791aacbcc4385ad32"}]},{"ProductId":"459b31cbafbe408eaf0a96421248c984","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"8008616","DateModified":"2025-11-17T06:44:15","FileList":["cp068633.xml","cpqsetup.exe","mnv_cli.exe","MPK78H5Q.rel","payload.json","setup.dll"],"MD5Sum":"d4348f0a5eb484b433f45a9fcd5aa4b8","Name":"cp068633.exe","Release":"2025-11-17T06:38:19","Revision":"C","SHA1Sum":"9db736246b59c83f06d19cf3299613b7f2c9a9df","SHA256Sum":"81d606c783a1d6f4c2438b144fed52cd7f930f4785982d83fedb517cea26cfc7","Size":"7MB","TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-0 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-0ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MZXL5960HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3936-304894dc03d2","Type":"nvme"},{"Id":"MZXL515THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3135-54486d0092b3","Type":"nvme"},{"Id":"MZXL512THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3132-544895b51a17","Type":"nvme"},{"Id":"MZXL57T6HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3754-364820f1a5c1","Type":"nvme"},{"Id":"MZXL56T4HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3654-34482ab7fb8f","Type":"nvme"},{"Id":"MZXL53T8HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-38483310a47b","Type":"nvme"},{"Id":"MZXL53T2HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-324884d9e9f5","Type":"nvme"},{"Id":"MZXL51T6HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-36487a9b1618","Type":"nvme"},{"Id":"MZXL5800HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3830-3048d90154e8","Type":"nvme"},{"Id":"MZXL51T9HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-3948e450274f","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T08:45:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"}],"SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e41a30bd00ab4b4ba56cdbac8a2e4498"}]},{"ProductId":"1f3d9896fbab4dc5aed295b2183323a0","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.54 (01/09/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.54 (01/09/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34242904","DateModified":"2026-01-14T05:43:48","FileList":["cp070256.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U46_2.54_01_09_2026.signed.flash"],"MD5Sum":"c20ee4c900682e1efb6e0f2a885bab14","Name":"cp070256.exe","Release":"2026-01-14T05:41:26","Revision":"","SHA1Sum":"180970632dc1cea5f198df6e8c306feb93f523fe","SHA256Sum":"e25e01430e292b92b73c367647394a19578499ceabbc98eaae32964115dff9a3","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus（U46）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:51:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Whitley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.802（2.50_07_24_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"76cdb0876f7b421f8027b3e5a268025e"}]},{"ProductId":"5e67b3914b754070a44558f816a7dbab","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作するHPE Intel icea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1724400","DateModified":"2025-11-16T10:47:13","FileList":["cp069533.xml","cpqsetup.exe","cp_data.xml","icea68.cat","icea68.din","icea68.inf","icea68.sys","iceamsg.dll","install.xml","manifest_icea68.man","nicdrvr.dll"],"MD5Sum":"8454d9814198b6d1804d44e22e04d3cc","Name":"cp069533.exe","Release":"2025-11-16T10:32:49","Revision":"B","SHA1Sum":"adf3b51aaae689972c46c3c2409efb2eaaeed204","SHA256Sum":"31c33633b19b9c9b2fee639fa26060127548c11bc4bbf123a578a889757e6768","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b103d04"],"TypeOfChange":"1","Version":"1.18.74.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icea Driver for Windows Server 2019"},{"Lang":"ja","Value":"Intel iceaドライバーfor Windows Server 2019"},{"Lang":"cn","Value":"Intel icea Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:50:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"cn"}],"Version":"1.18.74.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced traffic flow in queue map rebalance.</li><li>This product enhanced &nbsp;media type detection over PHY logic.</li></ul>","Fixes":"<p>This product fixed the system event logging.</p>","Lang":"cn"}],"Version":"1.18.74.0"}],"SWKeys":[{"Name":"icea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a1cfc287221841b3b9741b9423a52863"}]},{"ProductId":"58dd146b67a34b2492cfd64a1feceec4","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."},{"Lang":"ja","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."},{"Lang":"cn","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 and above adapters."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li><li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li><li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li><li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li><li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX8</strong>:<ul><li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li><li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li></ul></li></ul>"}],"Files":[{"Bytes":"2661038","DateModified":"2025-10-22T10:49:38","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/compat","./lib/modules/6.4.0-150600.21-default/updates/compat/mlx_compat.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers","./lib/modules/6.4.0-150600.21-default/updates/drivers/block","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd/rnbd-client.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd/rnbd-server.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl/fwctl.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/efa","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/erdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/erdma/erdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/irdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mana","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mthca","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qedr","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qib","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/usnic","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rxe","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/siw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/iser","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/isert","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srp","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/host","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/target","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.4.0-150600.21-default/updates/net","./lib/modules/6.4.0-150600.21-default/updates/net/9p","./lib/modules/6.4.0-150600.21-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/mlxdevm","./lib/modules/6.4.0-150600.21-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/6.4.0-150600.21-default/updates/net/rds","./lib/modules/6.4.0-150600.21-default/updates/net/rds/rds_rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/smc","./lib/modules/6.4.0-150600.21-default/updates/net/smc/smc.ko","./lib/modules/6.4.0-150600.21-default/updates/net/smc/smc_diag.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"MD5Sum":"479d7c4bc4ad85b7f183e1b337d12ae2","Name":"mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150600.21-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm","Release":"2025-10-22T08:42:04","Revision":"","SHA1Sum":"794b0730424bcc7a3a753937f76207acf1dfc06d","SHA256Sum":"be28e9b1cb1246479726bb80320810940327749583d6ae5a9fc7c42341731a99","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"25.07-0.9.7.0"},{"Bytes":"2040876","DateModified":"2025-10-22T10:45:18","FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.3.58.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.58.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.58.0","./usr/lib64/libibverbs/libmlx5-rdmav57.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.58.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.25.58.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.58.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/mlnx-ofa_kernel","./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/perftest","./usr/share/doc/packages/perftest/COPYING","./usr/share/doc/packages/perftest/README","./usr/share/doc/packages/perftest/runme","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"MD5Sum":"59d6479b3a0f2861c75c238dc2eaaca9","Name":"mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm","Release":"2025-10-22T08:42:04","Revision":"","SHA1Sum":"d31ba50e009d1299d3ceb0a937f3a77456e48305","SHA256Sum":"6f89579da60ee56b9f8ca88a5e115212bd29df403426413ce35fcefc37b4deea","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"25.07-0.9.7.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.07&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br /><br />To install or upgrade the driver:<br />If using 6.4.0-150600.21-default kernel or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150600.21-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.07&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br /><br />To install or upgrade the driver:<br />If using 6.4.0-150600.21-default kernel or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150600.21-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.07&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br /><br />To install or upgrade the driver:<br />If using 6.4.0-150600.21-default kernel or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.07-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-25.07_k6.4.0_150600.21-OFED.25.07.0.9.7.1.sles15sp6.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for SUSE LINUX Enterprise Server 15 SP6 (AMD64/EM64T)"},{"Lang":"ja","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for SUSE LINUX Enterprise Server 15 SP6 (AMD64/EM64T)"},{"Lang":"cn","Value":"HPE Mellanox RoCE Driver [ConnectX-4 and above] for SUSE LINUX Enterprise Server 15 SP6 (AMD64/EM64T)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"1023","SubDev":"0002","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102315b30002","Type":"pci","Ven":"15B3"},{"Dev":"1023","SubDev":"0006","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102315b30006","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1021","SubDev":"0073","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30073","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0086","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30086","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30074","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0085","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30085","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-07T12:13:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.04-0.6.1.1:</strong></p><ul><li>Trust Lockdown Health Syndrome: Added a new health syndrome for trust lockdown and expose the CRR bit in the health buffer. When the CRR bit is set, it indicates that the syndrome requires a cold reset for recovery.</li><li>A Single PTP Device per Hardware Clock: PHC is typically shared across multiple functions. Currently, the driver creates a separate PTP device for each network interface sharing the same PHC, resulting in redundancy and added complexity. To address this, a single PTP device is now created to represent the shared PHC when operating in real-time mode.</li><li>Log IB State Transitions: Enhanced visibility into IB device state transitions by adding log messages to the kernel log (dmesg). Each time an IB device changes state, a corresponding message will be logged. For example: &quot;mlx5_0: Port: 1 Link DOWN&quot;.</li><li>Optional-counters Binding Support and New Packets/bytes Counters: Previously, optional counters were available only on a per-link basis. This release introduces the ability to bind optional counters to a specific counter object, enabling users to track optional counters across a specific QP group. Support is provided for both automatic and manual binding modes. In both cases, the optional counters that are bound to the QP are those currently configured on the link at the time of binding. Additionally, four new optional counters that track RDMA ingress and egress traffic are introduced: rdma_tx_bytes; rdma_tx_packets; rdma_rx_bytes; rdma_rx_packets. This functionality is exposed to users via the iproute2 package, which must be updated to support this feature.</li><li>User CAPability (UCAP) API: The User CAPability (UCAP) API introduces a mechanism for creating user contexts with specific firmware privileges. It offers fine-grained control over firmware features by exposing each capability as a character device with root-level read-write access. Root processes can grant users these privileges by allowing access to the corresponding character devices. When a user context is created using a UCAP file descriptor, it inherits the associated privileges. For mlx5, two UCAP character devices are provided, and any user context opened with at least one of them is treated as privileged. To guarantee the execution of privileged commands, non-privileged commands are restricted when a privileged user is active on the device.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.04-0.6.1.1:</strong></p><ul><li>Buffer initialization became a performance bottleneck during the allocation of large buffers, typically when using a high number of QPs with large message sizes. The root cause was the inefficient use of rand(). This has been resolved by replacing it with a faster pseudo-random algorithm.</li><li>A potential deadlock that could occur during the handling of peer memory registration failures.</li><li>The following error occurred when switching to SwitchDev mode: &quot;mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)&quot;</li><li>A sysfs issue that occurred when accessing hardware counters from within a namespace.</li><li>&quot;ibstat&quot; would fail and crash when encountering a non-RoCE/IB device, preventing it from displaying information for the remaining valid RoCE/IB devices.</li><li>Bandwidth degradation in cases of high number of QPs, where polling only 16 CQEs per iteration may not be sufficient to process all completions in time.</li><li>A race condition between firmware syndrome report and driver initialization during boot.</li><li>The driver failed to load when a firmware syndrome was detected during boot.</li><li>The mlnx_tune -l command did not list several operating systems that were in fact supported.</li><li>The kernel did not define TCA_TUNNEL_KEY_ENC_SRC_PORT. To align offload behavior with non-offload, the OVS community introduced a commit ( netdev-offload-tc: Fix offload of tunnel key tp_src) that causes offload to fail if this tunnel attribute is used. Now, any rule with a tunnel set action that includes a tunnel source port can no longer be offloaded.</li><li>LLDP traffic from VFs or BF host PFs was not reaching the representor kernel interfaces.</li><li>Flows where both the inner and outer destination (dst) and/or source (src) MAC addresses were rewritten to the same value, the outer MAC address rewrite was ignored, leading to an outer MAC address of 00:00:00:00:00:00.</li><li>Enabling sFlow with OVN caused OVS to crash.</li><li>OVS crashed unexpectedly after DPUs repeatedly broadcast the error message &ldquo;packet with own source address.&rdquo;</li><li>Changing the hw-offload setting from true to false while ports were configured led to errors reported in the OVS log.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン25.04-0.6.1.1には、次の新機能と変更が含まれています。</strong></p><ul><li>トラストロックダウンヘルスシンドローム：トラストロックダウン用の新しいヘルスシンドロームを追加し、ヘルスバッファー内のCRRビットを公開します。CRRビットが設定されている場合、シンドロームの回復にはコールドリセットが必要であることを示しています。</li><li>ハードウェアクロックごとに1つのPTPデバイス：PHCは通常、複数の機能間で共有されます。現在、ドライバーは同じPHCを共有するネットワークインターフェイスごとに個別のPTPデバイスを作成するため、冗長性があり、複雑さが増しています。この問題を解決するために、リアルタイムモードで動作しているときに共有されたPHCを表す1つのPTPデバイスが作成されるようになりました。</li><li>IB状態遷移のログ：カーネルログ (dmesg) にログメッセージを追加することで、IBデバイスの状態遷移の可視性が向上しました。IBデバイスの状態が変化するたびに、対応するメッセージが記録されます。例えば、\"mlx5_0: Port: 1 Link DOWN\"などです。</li><li>オプションカウンターのバインディングサポートと新しいパケット/バイトカウンター：以前は、オプションカウンターはリンクごとにのみ使用可能でした。このリリースでは、オプションカウンターを特定のカウンターオブジェクトにバインドする機能が導入され、ユーザーは特定のQPグループ全体でオプションカウンターを追跡できるようになりました。自動バインディングモードと手動バインディングモードの両方がサポートされます。どちらの場合も、QPにバインドされるオプションカウンターは、バインド時にリンク上で現在設定されているカウンターです。さらに、RDMAのイングレストラフィックとイーグレストラフィックを追跡する4つの新しいオプションカウンター (rdma_tx_bytes、rdma_tx_packets、rdma_rx_bytes、rdma_rx_packets) が導入されました。この機能はiproute2パッケージを介してユーザーに公開されますが、この機能をサポートするにはこのパッケージをアップデートする必要があります。</li><li>User CAPability (UCAP) API：User CAPability (UCAP) APIは、特定のファームウェア権限を持つユーザーコンテキストを作成するためのメカニズムを導入します。各機能をルートレベルの読み取り/書き込みアクセスを持つキャラクター型デバイスとして公開することで、ファームウェア機能に対するきめ細かな制御を実現します。ルートプロセスでは、対応するキャラクター型デバイスへのアクセスを許可することで、ユーザーにこれらの権限を付与できます。UCAPファイル記述子を使用してユーザーコンテキストが作成されると、ユーザーコンテキストは関連付けられている権限を継承します。mlx5の場合、2つのUCAPキャラクター型デバイスが提供され、そのうちの少なくとも1つを使用して開かれたユーザーコンテキストが特権として扱われます。特権コマンドの実行を保証するために、特権ユーザーがデバイス上でアクティブな場合、非特権コマンドが制限されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン25.04-0.6.1.1で修正されました。</strong></p><ul><li>メッセージサイズの大きい多数のQPを使用する場合など、大きなバッファーの割り当て中に、バッファーの初期化がパフォーマンスのボトルネックになっていました。根本的な原因は、rand() の非効率的な使用でした。この問題は、より高速な疑似ランダムアルゴリズムに置き換えることで解決されました。</li><li>ピアメモリ登録の失敗の処理中に発生する可能性のあるデッドロック。</li><li>SwitchDevモードに切り替える際に次のエラーが発生しました。\"mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)\"</li><li>名前空間内からハードウェアカウンターにアクセスする際に発生したsysfsの問題。</li><li>\"ibstat\"は、RoCE/IB以外のデバイスを見つけると失敗してクラッシュし、残りの有効なRoCE/IBデバイスの情報を表示できなくなります。</li><li>QPの数が多い場合に帯域幅が低下し、反復ごとに16個のCQEをポーリングするだけでは、すべての完了を時間内に処理するのに十分ではない可能性があります。</li><li>ブート中のファームウェアシンドロームレポートとドライバー初期化の間の競合状態。</li><li>ブート中にファームウェアシンドロームが検出されたため、ドライバーのロードに失敗しました。</li><li>mlnx_tune -lコマンドでは、実際にサポートされているいくつかのオペレーティングシステムがリストされませんでした。</li><li>カーネルはTCA_TUNNEL_KEY_ENC_SRC_PORTを定義しませんでした。オフロードの動作を非オフロードと一致させるために、OVSコミュニティは、このトンネル属性が使用されている場合にオフロードが失敗するコミット (netdev-offload-tc：トンネルキーtp_srcのオフロードを修正) を導入しました。これで、トンネルのソースポートを含むトンネルセットアクションを持つすべてのルールはオフロードできなくなります。</li><li>VFまたはBFホストPFからのLLDPトラフィックが、リプレゼンターカーネルインターフェイスに到達していませんでした。</li><li>内部と外部の両方の宛先 (dst) および/または送信元 (src) MACアドレスが同じ値に書き換えられたフローで、外部MACアドレスの書き換えは無視され、外部MACアドレスが00:00:00:00:00:00 になります。</li><li>OVNでsFlowを有効にすると、OVSがクラッシュしました。</li><li>DPUが\"packet with own source address\"というエラーメッセージを繰り返しブロードキャストした後、OVSが予期せずクラッシュしました。</li><li>ポートの設定中にhw-offload設定をtrueからfalseに変更すると、OVSログにエラーが報告されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.04-0.6.1.1:</strong></p><ul><li>Trust Lockdown Health Syndrome: Added a new health syndrome for trust lockdown and expose the CRR bit in the health buffer. When the CRR bit is set, it indicates that the syndrome requires a cold reset for recovery.</li><li>A Single PTP Device per Hardware Clock: PHC is typically shared across multiple functions. Currently, the driver creates a separate PTP device for each network interface sharing the same PHC, resulting in redundancy and added complexity. To address this, a single PTP device is now created to represent the shared PHC when operating in real-time mode.</li><li>Log IB State Transitions: Enhanced visibility into IB device state transitions by adding log messages to the kernel log (dmesg). Each time an IB device changes state, a corresponding message will be logged. For example: &quot;mlx5_0: Port: 1 Link DOWN&quot;.</li><li>Optional-counters Binding Support and New Packets/bytes Counters: Previously, optional counters were available only on a per-link basis. This release introduces the ability to bind optional counters to a specific counter object, enabling users to track optional counters across a specific QP group. Support is provided for both automatic and manual binding modes. In both cases, the optional counters that are bound to the QP are those currently configured on the link at the time of binding. Additionally, four new optional counters that track RDMA ingress and egress traffic are introduced: rdma_tx_bytes; rdma_tx_packets; rdma_rx_bytes; rdma_rx_packets. This functionality is exposed to users via the iproute2 package, which must be updated to support this feature.</li><li>User CAPability (UCAP) API: The User CAPability (UCAP) API introduces a mechanism for creating user contexts with specific firmware privileges. It offers fine-grained control over firmware features by exposing each capability as a character device with root-level read-write access. Root processes can grant users these privileges by allowing access to the corresponding character devices. When a user context is created using a UCAP file descriptor, it inherits the associated privileges. For mlx5, two UCAP character devices are provided, and any user context opened with at least one of them is treated as privileged. To guarantee the execution of privileged commands, non-privileged commands are restricted when a privileged user is active on the device.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.04-0.6.1.1:</strong></p><ul><li>Buffer initialization became a performance bottleneck during the allocation of large buffers, typically when using a high number of QPs with large message sizes. The root cause was the inefficient use of rand(). This has been resolved by replacing it with a faster pseudo-random algorithm.</li><li>A potential deadlock that could occur during the handling of peer memory registration failures.</li><li>The following error occurred when switching to SwitchDev mode: &quot;mlx5_core 0000:03:00.0: mlx5_cmd_out_err:835:(pid 24362): CREATE_FLOW_GROUP(0x933) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x4065f0), err(-22); mlx5_core 0000:03:00.0: E-Switch: Failed to create peer miss flow group err(-22)&quot;</li><li>A sysfs issue that occurred when accessing hardware counters from within a namespace.</li><li>&quot;ibstat&quot; would fail and crash when encountering a non-RoCE/IB device, preventing it from displaying information for the remaining valid RoCE/IB devices.</li><li>Bandwidth degradation in cases of high number of QPs, where polling only 16 CQEs per iteration may not be sufficient to process all completions in time.</li><li>A race condition between firmware syndrome report and driver initialization during boot.</li><li>The driver failed to load when a firmware syndrome was detected during boot.</li><li>The mlnx_tune -l command did not list several operating systems that were in fact supported.</li><li>The kernel did not define TCA_TUNNEL_KEY_ENC_SRC_PORT. To align offload behavior with non-offload, the OVS community introduced a commit ( netdev-offload-tc: Fix offload of tunnel key tp_src) that causes offload to fail if this tunnel attribute is used. Now, any rule with a tunnel set action that includes a tunnel source port can no longer be offloaded.</li><li>LLDP traffic from VFs or BF host PFs was not reaching the representor kernel interfaces.</li><li>Flows where both the inner and outer destination (dst) and/or source (src) MAC addresses were rewritten to the same value, the outer MAC address rewrite was ignored, leading to an outer MAC address of 00:00:00:00:00:00.</li><li>Enabling sFlow with OVN caused OVS to crash.</li><li>OVS crashed unexpectedly after DPUs repeatedly broadcast the error message &ldquo;packet with own source address.&rdquo;</li><li>Changing the hw-offload setting from true to false while ports were configured led to errors reported in the OVS log.</li></ul>","Lang":"cn"}],"Version":"25.04-0.6.1.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.07-0.9.7.1:</strong><br />&nbsp;</p><ul><li>Hardware Steering (HWS): Enabled HWS as a secondary option for the device steering mode. If Software Steering (SWS) is not supported, HWS will be used by default, assuming it is available. Firmware Steering (FW) will now serve as the default only when both SWS and HWS are unsupported.</li><li><p>Hardware-Managed Flow Steering (HMFS): HMFS is a new approach to managing steering rules, where STEs are written to the ICM by hardware instead of software (as in software-managed steering). This enables a higher rate of rule insertion.</p></li><li><p>Queue Affinity Bonding: Added support for 4-port bonding to allow users to add both p0 and p1 to a bond without requiring SSH access to the host or bringing down the driver beforehand.</p></li><li><p>Multiple Doorbells per PF: Increased the number of doorbells from 1 to 8, distributing them in a round-robin manner across channel send and receive queues. This enhancement improves scalability on multi-core systems with high packet rates by reducing MMIO contention on doorbell addresses. In high packet-rate scenarios, Sub-NUMA Clustering is also required to maintain consistent channel packet rates.</p></li><li><p>HQoS for Virtualization Solution: Added support for hierarchical group structures to enable multi-tier resource control, where parent groups enforce overall limits and child groups dynamically share available bandwidth. This design is essential for effective QoS enforcement, burst handling, and fair bandwidth allocation, ensuring workloads receive appropriate resources.</p></li><li><p>Number of lanes Configuration when Auto-Negotiation is Disabled: Added support for specifying the number of lanes (protocol width) when auto-negotiation is disabled. Since each combination of speed and lane count corresponds to a unique link mode, this allows the user to select a specific link mode when auto-negotiation is off. This change aligns with a recent firmware update that requires the driver to provide a single link mode, rather than a bitmap based on the user-defined speed.</p></li><li>Extend ODP Statistics with Operation Count: Added the following new page-granularity counters:<ul><li>num_page_faults: counts the number of page fault events handled</li><li>num_invalidations: counts the number of page invalidation events handled</li></ul></li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.07-0.9.7.1:</strong></p><ul><li>OFED installation caused CIFS to break in RHEL 8.4 and above. A dummy module was added so that CIFS will be disabled after OFED installation in RHEL 8.4 and above.</li><li>Performance degradation on older kernel versions using RX cache, particularly on slower ARM CPUs with larger RX buffers. The issue was caused by the driver attempting to allocate new RX pages too quickly, leading to head-of-line blocking in the RX cache. The fix improves RX cache usage by triggering page allocation for a bulk of at least 2 WQEs, allowing the application more time to process packets and return buffers to the RX cache, thereby reducing blocking and enhancing performance.</li><li>VF behavior was not aligned with /sys/class/net/&lt;interface-name&gt;/device/sriov_numvfs (silently ignore attempts to set the same number of VFs, and prevent changing the number of VFs until existing VFs are removed).</li><li>On BlueField-3 devices running linux-bluefield kernel versions 5.15.0-1050 or 5.15.0-1060, a kernel crash occurred due to a NULL pointer dereference in the cls_api network scheduler.</li></ul>","Lang":"cn"}],"Version":"25.07-0.9.7.0"}],"SWKeys":[{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c075bef6e321486a9387a59ef84f58f4"}]},{"ProductId":"a4fb8dc02faf478a85519ccf77530c6a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following SATA drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。VK000480GWTHA、VK000960GWTHB、VK001920GWTHC およびVK003840GWTHDドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for VMware 8.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li><li>Fix with SOULAPI/SSACLI to clear MnP data and reset the predictive failure count.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for VMware 8.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li><li>Fix with SOULAPI/SSACLI to clear MnP data and reset the predictive failure count.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"19818467","DateModified":"2025-03-06T08:30:19","FileList":["/CP066023_BUILD_6.data","/CP066023.vmexe64","/CP066023.vmfile","/CP066023_VMw.zip","/CP066023.xml","/payload.json","/CP066023_VMw.zip/index.xml","/CP066023_VMw.zip/vendor-index.xml","/CP066023_VMw.zip/metadata.zip","/CP066023_VMw.zip/vib20/CP066023/HPE_bootbank_CP066023_HPG5.6-1OEM.800.1.0.20613240.vib","/CP066023_VMw.zip/metadata.zip/vendor-index.xml","/CP066023_VMw.zip/metadata.zip/vmware.xml","/CP066023_VMw.zip/metadata.zip/vibs/CP066023-4780014556907800122.xml","/CP066023_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066023_HPG5.6-1OEM.800.1.0.20613240.xml"],"MD5Sum":"b40c669393229da68f21a54847613811","Name":"CP066023.zip","Release":"2025-03-06T08:29:38","Revision":"C","SHA1Sum":"2646db2378fee9d3092b3e5fe8eb78b5b6d0299b","SHA256Sum":"1b649ff3975327f7fda1b05e2ac0e487a07c70d9f687646eaa8835849971823d","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP066023","Version":"HPG5.6-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041496.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi -VK000480GWTHA、VK000960GWTHB、VK001920GWTHCおよびVK003840GWTHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK003840GWTHD","TargetGUID":"562340a5-304b-3330-3834-304757544844","Type":"sata"},{"Id":"VK001920GWTHC","TargetGUID":"562340a5-304b-3130-3932-304757544843","Type":"sata"},{"Id":"VK000960GWTHB","TargetGUID":"562340a5-304b-3030-3936-304757544842","Type":"sata"},{"Id":"VK000480GWTHA","TargetGUID":"562340a5-304b-3030-3438-304757544841","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T08:25:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>修正には、SMARTレポートのコードの改善が含まれています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3517de8f98024d459a4a29c680e11ef7"}]},{"ProductId":"a88170da558d4ca79c0a5aa7982152c5","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、MB016000GWZHD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19899653","DateModified":"2025-03-06T12:40:23","FileList":["/CP065964_BUILD_6.data","/CP065964.vmexe64","/CP065964.vmfile","/CP065964_VMw.zip","/CP065964.xml","/payload.json","/CP065964_VMw.zip/index.xml","/CP065964_VMw.zip/vendor-index.xml","/CP065964_VMw.zip/metadata.zip","/CP065964_VMw.zip/vib20/CP065964/HPE_bootbank_CP065964_HPG1.6-8.0.0.20613240.vib","/CP065964_VMw.zip/metadata.zip/vendor-index.xml","/CP065964_VMw.zip/metadata.zip/vmware.xml","/CP065964_VMw.zip/metadata.zip/vibs/CP065964-4772671323534759563.xml","/CP065964_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065964_HPG1.6-8.0.0.20613240.xml"],"MD5Sum":"ce46d261fa05e83eca120b09b006fbd6","Name":"CP065964.zip","Release":"2025-03-06T12:39:35","Revision":"E","SHA1Sum":"79eda59b2ca24878d51e49c9a86b71149198a8b8","SHA256Sum":"762429956e3644404daa1e6333e61b33d7d20b8af87cacd92a86a976bef9e84e","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065964","Version":"HPG1.6-8.0.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、およびMB016000GWZHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB010000GWZGT","TargetGUID":"4d2340a5-3042-3031-3030-3047575a4754","Type":"sata"},{"Id":"MB012000GWZGU","TargetGUID":"4d2340a5-3042-3231-3030-3047575a4755","Type":"sata"},{"Id":"MB014000GWZGV","TargetGUID":"4d2340a5-3042-3431-3030-3047575a4756","Type":"sata"},{"Id":"MB016000GWZHD","TargetGUID":"4d2340a5-3042-3631-3030-3047575a4844","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:21:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ea988c1bdb0e488ea2464583c089174e"}]},{"ProductId":"d6cef3e7c9484a989ca5a04fc11b29f2","Versions":[{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Power Management"},{"Lang":"ja","Value":"ファームウェア - パワー マネジメント"},{"Lang":"cn","Value":"固件 - 电源管理"}],"Description":[{"Lang":"en","Value":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたアドバンスト消費電力上限マイクロコントローラーファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"219817","DateModified":"2025-11-26T03:47:51","FileList":["./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/CP069832.xml","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/PICGen10_v1.1.4_hdr.signed.hex","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069832.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069832.scexe"],"MD5Sum":"9992584bb4d59eabe7c3ccd9add1f1b8","Name":"firmware-powerpic-gen10-1.1.4-8.1.x86_64.rpm","Release":"2025-11-26T09:39:04","Revision":"H","SHA1Sum":"ec8a3f519afbb0cb2d7c0aef6e8ffdce2f89d8d7","SHA256Sum":"ef707a05ac142870ea9e50ba4ec8acb4c6114eb8d1a1b92f84e418178d3df084","Size":"214KB","TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュ for Linux - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen10およびGen10 PlusおよびML30 Gen11サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-26T09:34:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>Ver. 1.1.4(H) contains updates to the firmware packaging and is functionally equivalent to ver. 1.1.4. It is not necessary to upgrade with Revision H if a previous component revision was used to upgrade the firmware to version 1.1.4.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>Ver. 1.1.4(H) contains updates to the firmware packaging and is functionally equivalent to ver. 1.1.4. It is not necessary to upgrade with Revision H if a previous component revision was used to upgrade the firmware to version 1.1.4.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>Ver. 1.1.4(H) contains updates to the firmware packaging and is functionally equivalent to ver. 1.1.4. It is not necessary to upgrade with Revision H if a previous component revision was used to upgrade the firmware to version 1.1.4.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"}],"SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DX360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"305cf0a5e6cf4fedb2bbda773704fad9"}]},{"ProductId":"9a8025d60954436ba6fa5cef6da3dd18","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for DL20 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SC_DL20GEN10Plus_ME_06.00.03.708.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2283823","DateModified":"2025-07-31T08:53:15","FileList":["payload.json","SC_DL20GEN10Plus_ME_06.00.03.708.signed.bin","SC_DL20GEN10Plus_ME_06.00.03.708.xml"],"MD5Sum":"aa55375d419e2d602cf6dfa10ccd01a8","Name":"SC_DL20GEN10Plus_ME_06.00.03.708.fwpkg","Release":"2025-07-31T08:51:29","Revision":"","SHA1Sum":"133154a61d408c825e0ab22bea7c4e9301b710c7","SHA256Sum":"ce42fd111d3fd8686224ca7df607959803e96662b70a4a884418e19bc4de6eb1","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェアfor HPE ProLiant DL20 Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-31T06:49:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.700 (2.30_01_07_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"06.00.03.708"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"2052e9792f184ea8bc1a949a0ba32149"}]},{"ProductId":"29921b6ba8e14e7cbeb3829f2308a0f5","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.41.032","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.44.040_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002db","Version":"03.01.44.040"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.41.032","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.44.040_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f1590032e","Version":"03.01.44.040"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.41.032","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.44.040_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900381","Version":"03.01.44.040"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.41.032","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.44.040_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002dc","Version":"03.01.44.040"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.41.032","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.44.040_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900294","Version":"03.01.44.040"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE SR932i-p Gen10, SR416i-a Gen10 Plus and SR932i-p, SR416ie-m Gen11 Controllers."},{"Lang":"ja","Value":"ユニバーサルファームウェアPLDMファイルfor HPE SR932i-p Gen10、SR416i-a Gen10 PlusおよびSR932i-p、SR416ie-m Gen11コントローラー"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE SR932i-p Gen10, SR416i-a Gen10 Plus and SR932i-p, SR416ie-m Gen11 Controllers."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12474398","DateModified":"2025-12-10T06:43:09","FileList":["HPE_SR416_SR932_Gen10P_Gen11_03.01.44.040_A.HPb","HPE_SR416_SR932_Gen10P_Gen11_03.01.44.040_A.xml","payload.json"],"MD5Sum":"05261e57bbe84a7842ec466cf3bf9f5d","Name":"HPE_SR416_SR932_Gen10P_Gen11_03.01.44.040_A.fwpkg","Release":"2025-12-10T06:37:17","Revision":"","SHA1Sum":"a4ed769a20b5dd06ecd90e6f67a3df44b6910e0e","SHA256Sum":"52e790d196402725e492db8fcd5fb03d51c589e43df355dbfdedd6c19fba6f4c","Size":"11MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"TypeOfChange":"1","Version":"03.01.44.040"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager (SUM) を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/connect/s/product?language=en_US&kmpmoid=7630408&tab=driversAndSoftware&driversAndSoftwareFilter=8000078\">iLO Restfulインターフェイスツール</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>    ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>     アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11コントローラー"},{"Lang":"cn","Value":"Firmware Package - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"12000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:29:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Enhanced functionality to expose the NVMe drive form factor based on the NVMe-MI specification&nbsp;</li><li>Optimized drive temperature checking for expander-based topologies.&nbsp;</li><li>Added support to write transformation backup data to an additional drive that is part of a fault-tolerant RAID volume to ensure data redundancy.&nbsp;</li><li>Added SSD life expectancy monitoring.&nbsp;</li><li>Added support to require privileged operations token for all RDE ACTION operations, including Drive.Reset and Storage.SetEncryptionKey, improving security for data-destructive actions.&nbsp;</li><li>Added support to provide meaningful update Interval values for Numeric Sensor PDRs, setting 5 seconds for controller temperature and 60 seconds for drive temperature sensors.&nbsp;</li><li>Enhanced the calculation of CapacityBytes@Redfish.AllowableNumbers for Volume Capabilities. The maximum allowable value is now set to the larger of (a) the largest free space range on any existing array, or (b) the sum of unassigned drives with a common interface and media type.&nbsp;</li><li>Enhanced DriveMetrics support by updating the schema version from 1.0.0 to 1.2.0, adding reporting for ReadIOKiBytes and WriteIOKiBytes properties.&nbsp;</li><li>Added an enhancement to display drive vendor and model name as separate fields in the Disk Information menu, improving clarity and ease of drive identification.&nbsp;</li><li>Added support to securely transfer encryption keys in remote key management mode.&nbsp;</li><li>Enhanced drive writes cache status reporting in HII.</li></ul>","Fixes":"<ul><li>Fixed an issue where SEDs reverting to foreign after controller reboot due to the otherwise owned flag not being saved to the datastore.&nbsp;</li><li>Fixed an issue where multiple logical drives incorrectly showing REBUILDING simultaneously due to rebuild status not being updated properly during queued transformation and rebuild processes&nbsp;</li><li>Fixed an issue where master key change failure on Managed SED logical drives due to LU cache flush requests conflicting with the password update process.&nbsp;</li><li>Fixed an issue where physical drive Predictive Failure status not reported correctly by tools and iLO.&nbsp;</li><li>Fixed an issue where controller lockup during surface scan caused by stale internal resources when handling Unrecoverable Read Errors (UREs) in unmapped logical drive regions.&nbsp;</li><li>Fixed an issue where drives being incorrectly failed during hot-plug due to UBM backplane misreporting drive status, with firmware workaround to wait for corrected reporting.&nbsp;</li><li>Fixed an issue where drive LED was being changed unexpectedly by preventing redundant LED commands when the current state already matches the target state.&nbsp;</li><li>Fixed an issue where NVMe drives being dropped after SEP firmware update and reset in mixed SAS/SATA and NVMe topologies due to missed hot plug events.&nbsp;</li><li>Fixed an issue where SATA drives could be incorrectly reported as hot-removed during spin-up by adjusting the dampen timer to align with vendor-specified TTR values.&nbsp;</li><li>Fixed an issue that could cause NVMe drive discovery to report incorrect information due to VPD read data length and device handle conversion errors.&nbsp;</li><li>Fixed an issue where the controller could lock up after a warm boot following a SAS Expander firmware update.&nbsp;</li><li>Fixed an issue where Micron 6550 SED drives could fail to create a Secured Volume due to insufficient timeout during the TCG Revert process.&nbsp;</li><li>Fixed an issue where the controller could lock up (0x1E30) under high I/O workloads when configuration changes occurred simultaneously with a LUN reset.&nbsp;</li><li>Fixed an issue where RAID 0 could hang with I/O timeouts and LUN resets during Predictive Spare Rebuild.&nbsp;</li><li>Fixed an issue where the controller Health state from PLDM PDRs could differ from the Storage.Status.HealthRollup value in RDE, by synchronizing the reporting logic.&nbsp;</li><li>Fixed an issue where SSD firmware updates could fail in dual path configurations due to PLDM errors, by sending Test Unit Ready commands to clear check conditions before SCSI passthrough operations.&nbsp;</li><li>Fixed an issue where Battery Redfish Alerts contained an incorrect OriginOfCondition pointing to a StorageController instead of the Battery resource.&nbsp;</li><li>Fixed an issue where RDE UPDATE operations on a Volume&rsquo;s ReadCachePolicy could incorrectly appear successful during a CBE rekey, by adjusting the cache update logic to return accurate results regardless of cache status.&nbsp;</li><li>Fixed an issue where the HotspareActivationPolicy allowable values incorrectly included OnDriveFailure for RAID 0 volumes with a dedicated spare, by adding configuration checks to ensure only valid values are shown.&nbsp;</li><li>Fixed an issue where there is a mismatch in Overall Health State and Logical Volume State during RPI, with sensors reporting Warning (Overall Health) while RDE READs ( Logical Volume State) showed OK; reporting OK during RPI is expected behavior.&nbsp;</li><li>Fixed an issue where firmware updates on SR932 Gen11 controllers could get stuck in the APPLY state when using PLDM Type 5. The firmware now pauses background activities during image flashing to ensure timely completion.&nbsp;</li><li>Fixed an issue where ProtectedWriteBack could incorrectly appear as an allowable WriteCachePolicy in RDE READs even without a backup power source, by requiring the power source to be connected and fully charged before publishing the option.&nbsp;</li><li>Fixed an issue where an RDE READ on certain unsupported Drive resources could cause a controller lockup, by adding bounds checking in the firmware API.&nbsp;</li><li>Fixed an issue where deleting volumes through PLDM Type 6 could cause a controller lockup if other PLDM commands were sent simultaneously. These commands now return NOT_READY when a long-running RDE operation is in progress.&nbsp;</li><li>Fixed an issue where disk utilities could display an invalid box number for drives after failing over to an alternative path, by ensuring only valid controller-provided information is shown.&nbsp;</li><li>Fixed an issue where an incorrect error message was shown in HII when creating a logical drive on a locked SED, by updating the error message to correctly reflect SED encryption.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>NVMe-MI仕様に基づいてNVMeドライブフォームファクターを公開する機能が強化されました </li><li>エクスパンダーベースのトポロジのドライブ温度チェックを最適化しました。 </li><li>データの冗長性を確保するために、フォールトトレラントRAIDボリュームの一部である追加のドライブに変換バックアップデータを書き込むサポートが追加されました。 </li><li>SSD寿命の監視を追加しました。 </li><li>Drive.ResetおよびStorage.SetEncryptionKeyを含むすべてのRDE ACTION操作に特権操作トークンを要求するサポートが追加され、データ破壊アクションのセキュリティが向上しました。 </li><li>数値センサーPDRに意味のあるアップデート間隔値を提供するためのサポートが追加されました。コントローラー温度の場合は5秒、ドライブ温度センサーの場合は60秒に設定します。 </li><li>ボリューム機能のCapacityBytes@Redfish.AllowableNumbersの計算が強化されました。最大許容値は、(a) 既存のアレイ上の最大空き領域範囲、または (b) 共通のインターフェースとメディア タイプを持つ未割り当てドライブの合計のうち大きい方に設定されます。 </li><li>スキーマバージョンを1.0.0から1.2.0にアップデートし、ReadIOKiBytesおよびWriteIOKiBytesプロパティのレポートを追加することで、DriveMetricsのサポートが強化されました。 </li><li>ディスク情報メニューでドライブのベンダー名とモデル名を個別のフィールドとして表示する機能強化が追加され、ドライブの識別が明確になり、容易になりました。 </li><li>リモートキー管理モードで暗号化キーを安全に転送するためのサポートが追加されました。 </li><li>HIIでのドライブ書き込みキャッシュステータスレポートが強化されました。</li></ul>","Fixes":"<ul><li>コントローラーの再起動後に、所有フラグがデータストアに保存されていないためにSEDが外部に戻ってしまう問題を修正しました。 </li><li>キューされた変換および再構築プロセス中に再構築ステータスが適切にアップデートされないため、複数の論理ドライブが同時に誤って「REBUILDING」と表示される問題を修正しました。 </li><li>LU キャッシュ フラッシュ要求がパスワードアップデートプロセスと競合するため、管理対象 SED 論理ドライブでマスター キーの変更が失敗する問題を修正しました。 </li><li>物理ドライブの予測障害ステータスがツールおよび iLO によって正しく報告されない問題を修正しました。 </li><li>マップされていない論理ドライブ領域で回復不可能な読み取りエラー (URE) を処理するときに、古い内部リソースが原因で表面スキャン中にコントローラーがロックアップする問題を修正しました。 </li><li>UBMバックプレーンがドライブステータスを誤って報告したためにホットプラグ中にドライブが誤って失敗する問題を修正しました。修正された報告を待機するためのファームウェア回避策が追加されました。 </li><li>現在の状態がターゲット状態と既に一致している場合に冗長なLEDコマンドを防止することにより、ドライブLEDが予期せず変更される問題を修正しました。 </li><li>ホットプラグイベントの欠落により、SAS/SATAとNVMeの混合トポロジでSEPファームウェアのアップデートとリセット後にNVMeドライブがドロップされる問題を修正しました。 </li><li>ベンダー指定のTTR値に合わせてダンプタイマーを調整することにより、スピンアップ中に SATAドライブがホットリムーブされたと誤って報告される可能性がある問題を修正しました。 </li><li>VPD読み取りデータ長とデバイス ハンドル変換エラーが原因で、NVMeドライブ検出で誤った情報が報告される可能性がある問題を修正しました。 </li><li>SASエクスパンダーのファームウェアアップデート後のウォーム ブート後にコントローラーがロックする可能性がある問題を修正しました。 </li><li>TCG復帰プロセス中にタイムアウトが不十分なためにMicron 6550 SEDドライブがセキュアボリュームを作成できない問題を修正しました。 </li><li>LUNリセットと同時に構成の変更が発生した場合、I/Oワークロードが高いときにコントローラーがロックアップする (0x1E30) 可能性がある問題を修正しました。 </li><li>予測スペア再構築中にRAID 0が I/OタイムアウトとLUNリセットでハングする可能性がある問題を修正しました。 </li><li>レポートロジックを同期することにより、PLDM PDRからのコントローラーのヘルス状態が RDE の Storage.Status.HealthRollup値と異なる可能性がある問題を修正しました。 </li><li>SCSIパススルー操作の前にチェック条件をクリアするためにTest Unit Readyコマンドを送信することにより、PLDMエラーが原因でデュアル パス構成でSSDファームウェアのアップデートが失敗する可能性がある問題を修正しました。 </li><li>Battery Redfish アラートに、バッテリー リソースではなくStorageControllerを指す誤った OriginOfCondition が含まれていた問題を修正しました。 </li><li>キャッシュアップデートロジックを調整して、キャッシュの状態に関係なく正確な結果を返すことにより、CBEキー再生成中にボリュームのReadCachePolicyに対するRDE UPDATE操作が誤って成功したように見える問題を修正しました。 </li><li>有効な値のみが表示されるように構成チェックを追加することで、専用スペアを持つRAID 0ボリュームのHotspareActivationPolicy許容値にOnDriveFailureが誤って含まれていた問題を修正しました。 </li><li>RPI中に全体的なヘルス状態と論理ボリューム状態に不一致があり、RDE READ (論理ボリューム状態) がOKを示しているのにセンサーが警告 (全体的なヘルス) を報告する問題を修正しました。RPI中に OKを報告することは想定された動作です。 </li><li>PLDMタイプ5を使用しているときに、SR932 Gen11コントローラーのファームウェアアップデートが APPLY状態で停止する可能性がある問題を修正しました。ファームウェアは、イメージのフラッシュ中にバックグラウンドアクティビティを一時停止して、タイムリーな完了を保証するようになりました。 </li><li>オプションを公開する前に電源を接続して完全に充電する必要があるため、バックアップ電源がない場合でも、ProtectedWriteBackがRDE READで許容されるWriteCachePolicyとして誤って表示される可能性がある問題を修正しました。 </li><li>ファームウェアAPIに境界チェックを追加することで、サポートされていない特定のドライブリソースに対するRDE READによってコントローラーがロックアップする可能性がある問題を修正しました。 </li><li>他のPLDMコマンドが同時に送信された場合に PLDMタイプ6を介してボリュームを削除するとコントローラーがロックアップする可能性がある問題を修正しました。これらのコマンドは、長時間実行されるRDE操作の進行中にNOT_READYを返すようになりました。 </li><li>コントローラーが提供する有効な情報のみが表示されるようにすることで、代替パスにフェイルオーバーした後にディスク ユーティリティがドライブの無効なボックス番号を表示する可能性がある問題を修正しました。 </li><li>ロックされたSED上に論理ドライブを作成するときにHIIに誤ったエラーメッセージが表示される問題を修正しました。この問題を修正するために、エラーメッセージをアップデートし、SED暗号化を正しく反映しました。 </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Enhanced functionality to expose the NVMe drive form factor based on the NVMe-MI specification&nbsp;</li><li>Optimized drive temperature checking for expander-based topologies.&nbsp;</li><li>Added support to write transformation backup data to an additional drive that is part of a fault-tolerant RAID volume to ensure data redundancy.&nbsp;</li><li>Added SSD life expectancy monitoring.&nbsp;</li><li>Added support to require privileged operations token for all RDE ACTION operations, including Drive.Reset and Storage.SetEncryptionKey, improving security for data-destructive actions.&nbsp;</li><li>Added support to provide meaningful update Interval values for Numeric Sensor PDRs, setting 5 seconds for controller temperature and 60 seconds for drive temperature sensors.&nbsp;</li><li>Enhanced the calculation of CapacityBytes@Redfish.AllowableNumbers for Volume Capabilities. The maximum allowable value is now set to the larger of (a) the largest free space range on any existing array, or (b) the sum of unassigned drives with a common interface and media type.&nbsp;</li><li>Enhanced DriveMetrics support by updating the schema version from 1.0.0 to 1.2.0, adding reporting for ReadIOKiBytes and WriteIOKiBytes properties.&nbsp;</li><li>Added an enhancement to display drive vendor and model name as separate fields in the Disk Information menu, improving clarity and ease of drive identification.&nbsp;</li><li>Added support to securely transfer encryption keys in remote key management mode.&nbsp;</li><li>Enhanced drive writes cache status reporting in HII.</li></ul>","Fixes":"<ul><li>Fixed an issue where SEDs reverting to foreign after controller reboot due to the otherwise owned flag not being saved to the datastore.&nbsp;</li><li>Fixed an issue where multiple logical drives incorrectly showing REBUILDING simultaneously due to rebuild status not being updated properly during queued transformation and rebuild processes&nbsp;</li><li>Fixed an issue where master key change failure on Managed SED logical drives due to LU cache flush requests conflicting with the password update process.&nbsp;</li><li>Fixed an issue where physical drive Predictive Failure status not reported correctly by tools and iLO.&nbsp;</li><li>Fixed an issue where controller lockup during surface scan caused by stale internal resources when handling Unrecoverable Read Errors (UREs) in unmapped logical drive regions.&nbsp;</li><li>Fixed an issue where drives being incorrectly failed during hot-plug due to UBM backplane misreporting drive status, with firmware workaround to wait for corrected reporting.&nbsp;</li><li>Fixed an issue where drive LED was being changed unexpectedly by preventing redundant LED commands when the current state already matches the target state.&nbsp;</li><li>Fixed an issue where NVMe drives being dropped after SEP firmware update and reset in mixed SAS/SATA and NVMe topologies due to missed hot plug events.&nbsp;</li><li>Fixed an issue where SATA drives could be incorrectly reported as hot-removed during spin-up by adjusting the dampen timer to align with vendor-specified TTR values.&nbsp;</li><li>Fixed an issue that could cause NVMe drive discovery to report incorrect information due to VPD read data length and device handle conversion errors.&nbsp;</li><li>Fixed an issue where the controller could lock up after a warm boot following a SAS Expander firmware update.&nbsp;</li><li>Fixed an issue where Micron 6550 SED drives could fail to create a Secured Volume due to insufficient timeout during the TCG Revert process.&nbsp;</li><li>Fixed an issue where the controller could lock up (0x1E30) under high I/O workloads when configuration changes occurred simultaneously with a LUN reset.&nbsp;</li><li>Fixed an issue where RAID 0 could hang with I/O timeouts and LUN resets during Predictive Spare Rebuild.&nbsp;</li><li>Fixed an issue where the controller Health state from PLDM PDRs could differ from the Storage.Status.HealthRollup value in RDE, by synchronizing the reporting logic.&nbsp;</li><li>Fixed an issue where SSD firmware updates could fail in dual path configurations due to PLDM errors, by sending Test Unit Ready commands to clear check conditions before SCSI passthrough operations.&nbsp;</li><li>Fixed an issue where Battery Redfish Alerts contained an incorrect OriginOfCondition pointing to a StorageController instead of the Battery resource.&nbsp;</li><li>Fixed an issue where RDE UPDATE operations on a Volume&rsquo;s ReadCachePolicy could incorrectly appear successful during a CBE rekey, by adjusting the cache update logic to return accurate results regardless of cache status.&nbsp;</li><li>Fixed an issue where the HotspareActivationPolicy allowable values incorrectly included OnDriveFailure for RAID 0 volumes with a dedicated spare, by adding configuration checks to ensure only valid values are shown.&nbsp;</li><li>Fixed an issue where there is a mismatch in Overall Health State and Logical Volume State during RPI, with sensors reporting Warning (Overall Health) while RDE READs ( Logical Volume State) showed OK; reporting OK during RPI is expected behavior.&nbsp;</li><li>Fixed an issue where firmware updates on SR932 Gen11 controllers could get stuck in the APPLY state when using PLDM Type 5. The firmware now pauses background activities during image flashing to ensure timely completion.&nbsp;</li><li>Fixed an issue where ProtectedWriteBack could incorrectly appear as an allowable WriteCachePolicy in RDE READs even without a backup power source, by requiring the power source to be connected and fully charged before publishing the option.&nbsp;</li><li>Fixed an issue where an RDE READ on certain unsupported Drive resources could cause a controller lockup, by adding bounds checking in the firmware API.&nbsp;</li><li>Fixed an issue where deleting volumes through PLDM Type 6 could cause a controller lockup if other PLDM commands were sent simultaneously. These commands now return NOT_READY when a long-running RDE operation is in progress.&nbsp;</li><li>Fixed an issue where disk utilities could display an invalid box number for drives after failing over to an alternative path, by ensuring only valid controller-provided information is shown.&nbsp;</li><li>Fixed an issue where an incorrect error message was shown in HII when creating a logical drive on a locked SED, by updating the error message to correctly reflect SED encryption.&nbsp;</li></ul>","Lang":"cn"}],"Version":"03.01.41.032"},{"ReleaseNotes":[{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC drop</li></ul>","Fixes":"","Lang":"cn"}],"Version":"03.01.44.040"}],"SWKeys":[{"Name":"02DB1590","SWKeyExpectedPath":"firmware"},{"Name":"032E1590","SWKeyExpectedPath":"firmware"},{"Name":"03811590","SWKeyExpectedPath":"firmware"},{"Name":"02941590","SWKeyExpectedPath":"firmware"},{"Name":"02DC1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"4b651fe2c7f1478eb6aa102fbf31bf1b"}]},{"ProductId":"c94eb717d55e4213952a8c5723962404","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U39_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11823576","DateModified":"2026-01-14T02:23:14","FileList":["cp070351.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U39_3.62_01_09_2026.signed.flash"],"MD5Sum":"de7fd3dba38d500756f60134c69140b8","Name":"cp070351.exe","Release":"2026-01-14T02:20:49","Revision":"","SHA1Sum":"0701b9ac1f1b2c31701738c581b0419aa9e80af0","SHA256Sum":"c9a6072b69d3cebce60926b56d927357d041d49d499f8447f6b7ccaef2bc0027","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:23:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"d9f050fc463a4c84943b175eb526c77e"}]},{"ProductId":"78667359eec84fc9af9066672db940e0","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp067979.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.802"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8576798","DateModified":"2025-08-04T04:08:56","FileList":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1/CP067981.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1/cp067979.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1/cp067979.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.802-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067981.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067981.scexe"],"MD5Sum":"b5c08e08f9fb78bdfbf575a6d85b0ced","Name":"firmware-spsgen10plus-04.04.04.802-1.1.x86_64.rpm","Release":"2025-08-04T08:59:16","Revision":"","SHA1Sum":"6ed72be5ba9b4300a4e028e1beca1d4c354770b1","SHA256Sum":"da9518f33d95e38d824c9ddb4a45e77bb453fc80f4965d6af2d4cf0cbef86626","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.802"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><p>&nbsp;</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p><p> </p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services（SPS）ファームウェアfor HPE Gen10 Plusサーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-30T01:47:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.04.04.702 (2.30_01_06_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.04.04.702"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"04.04.04.802"}],"SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"99bc27d52d4742a7ae087361736f94e1"}]},{"ProductId":"953566d3c1ab4efe9b762b361100a259","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b5a595755","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b5a595842","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b5a595843","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b5a595754","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b5a595756","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b5a595841","Version":"HPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[],"Files":[{"Bytes":"1596760","DateModified":"2023-12-03T22:38:13","FileList":["payload.json","Solidigm_P5x20_4IAAHPK5.HPb","Solidigm_P5x20_4IAAHPK5.xml"],"MD5Sum":"a9abe39a27df6cdc0a4b03bf19445629","Name":"Solidigm_P5x20_4IAAHPK5.fwpkg","Release":"2023-12-03T22:34:54","Revision":"","SHA1Sum":"4d418d328eece3582d53f2fd39f9304c156d1aa4","SHA256Sum":"da95c519e100811f753c052858be793683375405746f7285c42b897183e9079f","Size":"1MB","TargetGUIDs":["4d2340a5-304f-3130-3630-304b5a595755","4d2340a5-304f-3330-3230-304b5a595842","4d2340a5-304f-3630-3430-304b5a595843","562340a5-304f-3130-3932-304b5a595754","562340a5-304f-3330-3834-304b5a595756","562340a5-304f-3730-3638-304b5a595841"],"TypeOfChange":"1","Version":"HPK5"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO001600KZYWU","TargetGUID":"4d2340a5-304f-3130-3630-304b5a595755","Type":"nvme"},{"Id":"MO003200KZYXB","TargetGUID":"4d2340a5-304f-3330-3230-304b5a595842","Type":"nvme"},{"Id":"MO006400KZYXC","TargetGUID":"4d2340a5-304f-3630-3430-304b5a595843","Type":"nvme"},{"Id":"VO001920KZYWT","TargetGUID":"562340a5-304f-3130-3932-304b5a595754","Type":"nvme"},{"Id":"VO003840KZYWV","TargetGUID":"562340a5-304f-3330-3834-304b5a595756","Type":"nvme"},{"Id":"VO007680KZYXA","TargetGUID":"562340a5-304f-3730-3638-304b5a595841","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-01-03T17:01:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware provides bug fixes for the P5620/P5520.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware provides bug fixes for the P5620/P5520.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware provides bug fixes for the P5620/P5520.</li></ul>","Lang":"cn"}],"Version":"HPK5"}],"SWKeys":[{"Name":"MO001600KZYWU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KZYXB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KZYXC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KZYWT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KZYWV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KZYXA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"4412e3e7c98649b3bd32cc53ac661f12"}]},{"ProductId":"731d832691df4216b8c0e073e857b8b7","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H10","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H10_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33588462","DateModified":"2026-01-12T06:42:21","FileList":["H10_2.54_01_09_2026.signed.flash","H10_2.54_01_09_2026.xml","payload.json"],"MD5Sum":"3ec3f3e13419858c743b4e18d61fe0f1","Name":"H10_2.54_01_09_2026.fwpkg","Release":"2026-01-12T06:38:27","Revision":"","SHA1Sum":"1944fbe37bc04a06fc1eafd93dae76031ac4a745","SHA256Sum":"d6d22685a1595cd318828e54092d7abca4c34ed468ad62be07be6bd5edbfb305","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023a"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Edgeline e920、e920d、およびe920t CTOブレードサーバー（H10）"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:54:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where megacell batteries might not manifest correctly.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where megacell batteries might not manifest correctly.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where megacell batteries might not manifest correctly.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.52_10-03-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"H10","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"0f5daaa66be24706974a1e36ac27c398"}]},{"ProductId":"97b8f64d84c04c1a9c4048cae29b4037","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB016000JXLBAおよびMB018000JXLAU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"22256851","DateModified":"2025-03-07T06:43:51","FileList":["/CP065993_BUILD_4.data","/CP065993.vmexe64","/CP065993.vmfile","/CP065993_VMw.zip","/CP065993.xml","/payload.json","/CP065993_VMw.zip/index.xml","/CP065993_VMw.zip/vendor-index.xml","/CP065993_VMw.zip/metadata.zip","/CP065993_VMw.zip/vib20/CP065993/HPE_bootbank_CP065993_HPD3.4-1OEM.800.1.0.20613240.vib","/CP065993_VMw.zip/metadata.zip/vendor-index.xml","/CP065993_VMw.zip/metadata.zip/vmware.xml","/CP065993_VMw.zip/metadata.zip/vibs/CP065993--5394737546929750152.xml","/CP065993_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065993_HPD3.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"21d1a5ea703a30c1f156a174533d380f","Name":"CP065993.zip","Release":"2025-03-07T06:43:04","Revision":"C","SHA1Sum":"98d1aafdcbf371db3c3d13550fd008bdee4fee5a","SHA256Sum":"2b8d53a2965e857b934eab7d2ec8126f5a8094b3764d8c2b4cd064d0a304340f","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP065993","Version":"HPD3.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB016000JXLBAおよびMB018000JXLAUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB016000JXLBA","TargetGUID":"4d2340a5-3042-3631-3030-304a584c4241","Type":"sas"},{"Id":"MB018000JXLAU","TargetGUID":"4d2340a5-3042-3831-3030-304a584c4155","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:10:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2c7206dd3d23401086d8b25ae4891eaa"}]},{"ProductId":"c09de62648424d62a24c56f856946da6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZ1LB960HAJQ-00007","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"EDA7602Q.bin","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"EDA7602Q"},{"DeviceName":"MZ1LB1T9HALS-00007","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"EDA7602Q.bin","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"EDA7602Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Disk"},{"Lang":"ja","Value":"ファームウェア - ストレージ ディスク"},{"Lang":"cn","Value":"固件 - 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MZ1LB960HAJQ-00007, MZ1LB1T9HALS-00007 and MZ1LB3T8HMLA-00007 Drives that can be installed directly on HPE ProLiant m750/e920/t/d System running a supported Microsoft Windows Operating System installed in HPE Moonshot 1500 chassis and EL8000t."},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: MZ1LB960HAJQ-00007, MZ1LB1T9HALS-00007 and MZ1LB3T8HMLA-00007 Drives that can be installed directly on HPE ProLiant m750/e920/t/d System running a supported Microsoft Windows Operating System installed in HPE Moonshot 1500 chassis and EL8000t."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7190640","DateModified":"2026-01-21T20:58:21","FileList":["cp070450.xml","cpqsetup.exe","EDA7602Q.bin","ilorest_chif.dll","payload.json"],"MD5Sum":"241308c2725bda7bda1bd383c6086752","Name":"cp070450.exe","Release":"2026-01-21T20:41:00","Revision":"B","SHA1Sum":"d696ce86946a31e2d11a9e3f37be97722fa67079","SHA256Sum":"132377578ac6296559d4826dd661535538a15e26120020311eb0a2c20e33c9ba","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"EDA7602Q"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To install firmware from Windows operating system on target server:</strong></p><p>&nbsp;</p><p>Double click&nbsp;on CP0xxxxx.exe.</p><p>OR&nbsp;</p><p>Open command prompt from start menu<br />In command prompt, Navigate to the path where CP0xxxxx.exe is copied<br />Run the exe file example is shown below:<br />&nbsp;&nbsp; &nbsp;<br />&nbsp;&nbsp; &nbsp;&gt;&gt; CP0xxxxx.exe</p><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Microsoft Windows - MZ1LB960HAJQ-00007, MZ1LB1T9HALS-00007 and MZ1LB3T8HMLA-00007 Drives"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Microsoft Windows - MZ1LB960HAJQ-00007, MZ1LB1T9HALS-00007 and MZ1LB3T8HMLA-00007 Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"9000"},"SupportedDevices":[{"Id":"MZ1LB1T9HALS-00007","TargetGUID":"4d2340a5-315a-424c-3154-3948c2e5811f","Type":"nvme"},{"Id":"MZ1LB960HAJQ-00007","TargetGUID":"4d2340a5-315a-424c-3936-304820becacc","Type":"nvme"},{"Id":"MZ1LB3T8HMLA-00007","TargetGUID":"4d2340a5-315a-424c-3354-384894df255d","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"Microsoft Windows 11","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-21T20:38:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリースです</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"EDA7602Q"},{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"EDA7602Q"}],"SWKeys":[{"Name":"MZ1LB960HAJQ-00007","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZ1LB1T9HALS-00007","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8bb509c565c0443b889276758c8765ad"}]},{"ProductId":"a271f679286141d98830336f93a8205f","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17617990","DateModified":"2025-03-07T07:04:30","FileList":["/CP064921_BUILD_20.data","/CP064921.vmexe","/CP064921.vmexe64","/CP064921.vmfile","/CP064921_VMw.zip","/CP064921.xml","/payload.json","/CP064921_VMw.zip/index.xml","/CP064921_VMw.zip/vendor-index.xml","/CP064921_VMw.zip/metadata.zip","/CP064921_VMw.zip/vib20/CP064921/HPE_bootbank_CP064921_0.39.20-8.0.0.20613240.vib","/CP064921_VMw.zip/metadata.zip/vendor-index.xml","/CP064921_VMw.zip/metadata.zip/vmware.xml","/CP064921_VMw.zip/metadata.zip/vibs/CP064921--2304907022570380113.xml","/CP064921_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064921_0.39.20-8.0.0.20613240.xml"],"MD5Sum":"7bdc5e75c53cd688d3921f7b6c9df2ca","Name":"CP064921.zip","Release":"2025-03-07T06:58:55","Revision":"D","SHA1Sum":"92c172204866b9e2a62622288f519b212597a482","SHA256Sum":"4d904aee167e29b93775c553b186c0eac3bdea222bb2c9f4539f7c0bb10d1502","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39","VibList":[{"Name":"CP064921","Version":"0.39.20-8.0.0.20613240"}]}],"Installation":{"Command":"CP064921.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li><li>Boot from the newly created Service Pack for ProLiant USB key</li><li>Follow Smart Update Manager steps to complete firmware update</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP</li><li>Add the component to the SPP</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run SUM</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li><li>Follow Smart Update Manager Steps and complete the firmware update</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;<br /><strong>To use HP Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client</li><li>Select a server or cluster in the inventory tree</li><li>Click the HP Insight Management tab</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li><li>Boot from the newly created Service Pack for ProLiant USB key</li><li>Follow Smart Update Manager steps to complete firmware update</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP</li><li>Add the component to the SPP</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run SUM</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li><li>Follow Smart Update Manager Steps and complete the firmware update</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;<br /><strong>To use HP Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client</li><li>Select a server or cluster in the inventory tree</li><li>Click the HP Insight Management tab</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"cn","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li><li>Boot from the newly created Service Pack for ProLiant USB key</li><li>Follow Smart Update Manager steps to complete firmware update</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP</li><li>Add the component to the SPP</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run SUM</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li><li>Follow Smart Update Manager Steps and complete the firmware update</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;<br /><strong>To use HP Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client</li><li>Select a server or cluster in the inventory tree</li><li>Click the HP Insight Management tab</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーファームウェア"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-06T03:54:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Update build environment with SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SHA384でカーネル生成環境をアップデートします</li><li>OSをアップデートします</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Update build environment with SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"cn"}],"Version":"0.39"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Update build environment with Rhel9 SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Update build environment with Rhel9 SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Update build environment with Rhel9 SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"cn"}],"Version":"0.39"}],"SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5e1fddb843d64cc082b8f2361cbbfb50"}]},{"ProductId":"4c8bf8c7de4d42f19de7d71c6056b4ba","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"3737396","DateModified":"2025-08-03T00:57:44","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-1.1/CP067326.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-1.1/GPM1645ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067326.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067326.scexe"],"MD5Sum":"6cbe3534debb84e461d99b2aaa856a74","Name":"firmware-hdd-a07a420ed1_0HPD5-1.1_amd64.deb","Release":"2025-08-03T05:51:46","Revision":"","SHA1Sum":"1bc6ed388154c74cd57be38cff9256fa3e680d8f","SHA256Sum":"a9c08010f1e7af0df4fdbcddcb0d76762a23d6e349407ff84a356afd44f8209a","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP040349.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO006400JWZJT","TargetGUID":"562340a5-304f-3630-3430-304a575a4a54","Type":"sas"},{"Id":"VO003200JWZJR","TargetGUID":"562340a5-304f-3330-3230-304a575a4a52","Type":"sas"},{"Id":"VO001600JWZJQ","TargetGUID":"562340a5-304f-3130-3630-304a575a4a51","Type":"sas"},{"Id":"VO000800JWZJP","TargetGUID":"562340a5-304f-3030-3830-304a575a4a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:46:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9ff89ccd7ecd42f58c367388f32df0f3"}]},{"ProductId":"98a183458fbc454a86f635797ce90db5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"QLogic driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"QLogicドライバーfor VMware vSphere 9.0"},{"Lang":"cn","Value":"QLogic driver for VMware vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"717832","DateModified":"2025-04-09T05:14:56","FileList":["/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip","/cp066316.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/index.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/vendor-index.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.5.85.0-1OEM.900.0.24580437.vib","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip/vibs/qlnativefc--7359688079739690666.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437.xml"],"MD5Sum":"8f6d0d53ff8ed5d2c8a88b1221f7405a","Name":"cp066316.zip","Release":"2025-04-09T05:13:54","Revision":"","SHA1Sum":"6dedf80bd3c5dc4ef1c6eceb3a1f125a61bfde5f","SHA256Sum":"b7b7a8a31d407600a9f149486ddfeaed5264e451726819880ea58d09d50c42d4","Size":"701KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2025.05.01","VibList":[{"Name":"qlnativefc","Version":"5.5.85.0-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":380,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"},{"Lang":"cn","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"},{"Lang":"ja","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE QLogicファイバーチャネルドライバーコンポーネントfor VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T14:54:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.4.83.1<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン5.4.83.1<br />このドライバーは、VMware ESXi 9.0でのみサポートされています。</p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Driver version 5.4.83.1<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"},{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.5.85.0<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Driver version 5.5.85.0<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Driver version 5.5.85.0<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"}],"SWKeys":[{"Name":"qlnativefc:5.5.85.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.5.85.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b36a633ff667434295a5dcb82e072da5"}]},{"ProductId":"f12cb892007944f694736d03ec00543c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"5310831","DateModified":"2025-09-21T20:27:59","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/CP068913.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/GPM1645ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068913.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068913.scexe"],"MD5Sum":"ba9c522bc07045c31687a822d2bf5a27","Name":"firmware-hdd-a07a420ed1-HPD5-6.1.x86_64.rpm","Release":"2025-09-22T01:15:26","Revision":"F","SHA1Sum":"88b7cf0cd5752fc896dd18bc514db5659e8959ca","SHA256Sum":"85dafec3d8c68c68c90eab44b2418b2680c17ebbfabd353a0e027e863d1c21dd","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP040349.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO006400JWZJT","TargetGUID":"562340a5-304f-3630-3430-304a575a4a54","Type":"sas"},{"Id":"VO003200JWZJR","TargetGUID":"562340a5-304f-3330-3230-304a575a4a52","Type":"sas"},{"Id":"VO001600JWZJQ","TargetGUID":"562340a5-304f-3130-3630-304a575a4a51","Type":"sas"},{"Id":"VO000800JWZJP","TargetGUID":"562340a5-304f-3030-3830-304a575a4a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:53:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1da10066bcaf487dad617cdc66b75e8a"}]},{"ProductId":"a76e2531d46347fe8a21781398a9fa4d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3979312","DateModified":"2025-08-03T02:10:25","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-1.1/CP067349.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-1.1/SAVNGSDA.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067349.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067349.scexe"],"MD5Sum":"734166007b68067967aa8d86129d87b4","Name":"firmware-hdd-b04257b77b_0HPDA-1.1_amd64.deb","Release":"2025-08-03T07:03:58","Revision":"","SHA1Sum":"3b3f75cf33899e410c1284900eae8a8ff6a9bd74","SHA256Sum":"5faa58fa5188dfe42270aaf8fcfe12733044dd023a38b840e8303d57f770d316","Size":"3MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"TypeOfChange":"1","Version":"HPDA"}],"Installation":{"Command":"CP040271.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MM1000JEFRB and MM2000JEFRC Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MM1000JEFRB and MM2000JEFRC Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM1000JEFRB","TargetGUID":"002340a5-4d00-314d-3030-304a45465242","Type":"sas"},{"Id":"MM2000JEFRC","TargetGUID":"002340a5-4d00-324d-3030-304a45465243","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:41:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"MM1000JEFRB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MM2000JEFRC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2377dfa753824aa1b2fec717915b7265"}]},{"ProductId":"bce1dc60182942cc938b19de857de7fd","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5147640","DateModified":"2025-12-11T14:50:14","FileList":["Config.xml","cp070007.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-5.04-build-000.bin","VDUFlash.dll"],"MD5Sum":"eb0c6fda3a32dba25a44641d4174af04","Name":"cp070007.exe","Release":"2025-12-11T14:49:14","Revision":"O","SHA1Sum":"a882130d529949f6a07a90aecdde811cdc9aa1a8","SHA256Sum":"2a4c9fbb7203423a6e082f4380dc0e19ca1688347fdfcb06f58d9ae618795068","Size":"4MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/tD3600 /tD3700 /tD3610 /tD3710 /v5.04 /iReveille-Release-5.04-build-000.bin /lD3000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"cn","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"ja","Value":"Windows (x64)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2"},"SupportedDevices":[{"Id":"D3600","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Type":"sas"},{"Id":"D3610","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3700","TargetGUID":"b99dfb74-f0bc-464f-b418-cd186af467e1","Type":"sas"},{"Id":"D3710","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-09T10:04:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li><p>Enabled-ClusterS2Dコマンドは、NonStopソリューションのD3610ディスクエンクロージャー内のSATAドライブ上で実行すると正常に完了するようになりました。</p></li><li><p>SASドライブのドライブケースであるスマートキャリアは、D3610/D3710ドライブエンクロージャーで認証されるようになりました。</p></li><li><p>ファンモジュールAおよびBの問題を報告するために、新しい7セグメントエラーコードE0およびE1がそれぞれ追加されました。これらの新しいコードはD3610/D3710にのみ適用され、ファームウェア5.04を実行しているときにのみ表示されます。</p></li><li><p>I/Oモジュール内のストレージエンクロージャープロセッサーに障害が発生すると、プロセッサーを確実にオンラインに戻すために、ハードリセット（電源を切ってから電源を入れる）が実行されます。</p></li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">リリースノート<u></u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v275929/20-D3000-Gen10RN504P_ED16.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"}],"SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9c2e096616fa40d5a40729ac02f9f213"}]},{"ProductId":"e1df01bf9927457096858061671e6c6b","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.5"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4815166","DateModified":"2025-12-02T11:37:47","FileList":["/CP068478_BUILD_7.data","/CP068478.vmexe","/CP068478.vmexe64","/CP068478.vmfile","/CP068478_VMw.zip","/CP068478.xml","/payload.json","/CP068478_VMw.zip/index.xml","/CP068478_VMw.zip/vendor-index.xml","/CP068478_VMw.zip/metadata.zip","/CP068478_VMw.zip/vib20/CP068478/HPE_bootbank_CP068478_CP068478.7-1OEM.900.0.24755229.vib","/CP068478_VMw.zip/metadata.zip/vendor-index.xml","/CP068478_VMw.zip/metadata.zip/vmware.xml","/CP068478_VMw.zip/metadata.zip/vibs/CP068478-3329466201978295652.xml","/CP068478_VMw.zip/metadata.zip/bulletins/Smart-Component-CP068478_CP068478.7-1OEM.900.0.24755229.xml"],"MD5Sum":"9718ca9abda3cac0c9ae2d82b59bc7fb","Name":"CP068478.zip","Release":"2025-12-02T11:33:46","Revision":"","SHA1Sum":"7a198d3c510ff45ab8dde7c26ffa5ee68d83ee6f","SHA256Sum":"03ab8d120ec025f49141f286e8e3e7ce508a53beabf065be2fe6a3ddb214a2a4","Size":"4MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2025.11.01","VibList":[{"Name":"CP068478","Version":"CP068478.7-1OEM.900.0.24755229"}]}],"Installation":{"Command":"hpsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />Offline:</strong></p><ul><li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li></ul><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li><li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li><li>From the same directory, unzip the Smart Component.<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li><li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>To perform the standalone installation, execute the command:</li><li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li><li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:<ul><li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li></ul></li><li>To perform standalone installation of the firmware,Execute the command:<ul><li>./ Execute_Component</li></ul></li><li>Follow the directions given by the Smart Component</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host</li><li>Reboot your system, if required, for the firmware update to take effect</li></ul>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />Offline:</strong></p><ul><li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li></ul><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li><li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li><li>From the same directory, unzip the Smart Component.<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li><li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>To perform the standalone installation, execute the command:</li><li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li><li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:<ul><li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li></ul></li><li>To perform standalone installation of the firmware,Execute the command:<ul><li>./ Execute_Component</li></ul></li><li>Follow the directions given by the Smart Component</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host</li><li>Reboot your system, if required, for the firmware update to take effect</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  9.0"},{"Lang":"ja","Value":"HPE ファームウェアフラッシュ for Emulex ファイバーチャネルホストバスアダプターfor VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"20000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-21T09:52:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>Fixed the Following:</p><ol><li>Switch Login Incomplete After Firmware Upgrade</li><li>Boot Incomplete on RHEL 10</li></ol>","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>以下を修正しました。</p><ol><li>ファームウェアのアップグレード後にスイッチのログインが完了できない</li><li>RHEL 10でブートが完了できない</li></ol>","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.30</p></td><td><p dir=\"LTR\">14.4.473.29</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.30</td><td>14.4.473.30</td><td>14.4.473.29</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"<p>Fixed the Following:</p><ol><li>Switch Login Incomplete After Firmware Upgrade</li><li>Boot Incomplete on RHEL 10</li></ol>","Lang":"cn"}],"Version":"2025.09.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.731.5</p></td><td><p dir=\"LTR\">14.4.716.0</p></td><td><p dir=\"LTR\">14.4.718.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.731.5</td><td>14.4.731.5</td><td>14.4.716.0</td><td>14.4.718.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.11.01"}],"SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7b10adedc44b4ad684f4306ab603ab6e"}]},{"ProductId":"a2c850b33a31462c8693efedafbdd8b9","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.23"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"cn","Value":"此软件包含有用于升级在Linux x86_64平台下运行的HPE ProLiant QLogic FastLinQ千兆以太网卡固件所需的实用程序和二进制文件。"},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2252235","DateModified":"2025-07-23T22:01:07","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/CP067928.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/CP067928.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/nic_fw/ql_hp_ah_mbi_8.65.23.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067928.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067928.scexe"],"MD5Sum":"af3a05815afd6c268abf22e158873c9c","Name":"firmware-nic-qlogic-flq-1.25.0-2.1.x86_64.rpm","Release":"2025-07-24T02:53:45","Revision":"B","SHA1Sum":"494f9f040f65396b86fee8e2e353b6edb4ccd90d","SHA256Sum":"53f0235947cd9f55e4781c8ca9a090c4225261bd4da22bdae5d47e71d40f4712","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"1.25.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p><ul><li>ファームウェアrpmパッケージをインストールします。<br /><em>> rpm -ivh <rpm_filename>.rpm </em></li><li>ファイルを抽出する場所を確認します。<br /><em>> rpm -qlp <rpm_filename>.rpm</em></li><li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li></ul><p> </p><p><strong><em>追加情報:</em></strong></p><ul><li>詳細情報はCPxxxxxx.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCPxxxxxx.logに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li><li>ファームウェア8.35.43は、'HPE Ethernet 10/25Gb 2ポート622FLR-SFP28コンバージドネットワークアダプター'の追加のネットワーク機能を実現することに注意してください。したがって、アダプターを8.35.43またはそれ以降にアップデートすると、バージョン8.35.43よりも古いバージョンにダウングレードすることはできません。</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"适用于 Linux x86_64 的 HPE QLogic FastLinQ 在线固件升级实用程序"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-24T02:23:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.25.0"},{"ReleaseNotes":[{"Enhancements":"<p>Initial version for Red Hat Enterprise Linux 10 support.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Initial version for Red Hat Enterprise Linux 10 support.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial version for Red Hat Enterprise Linux 10 support.</p>","Fixes":"","Lang":"cn"}],"Version":"1.25.0"}],"SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"04f079dbe182468f8c1d66faa87a37db"}]},{"ProductId":"596340d3247946aaa109faeb065a7eab","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6288091","DateModified":"2025-09-17T11:45:05","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/CP068846.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/HVLPeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068846.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068846.scexe"],"MD5Sum":"c230ab94d8fb768e5427a9cb67c7cc13","Name":"firmware-hdd-8b26d1ef02-HPD2-11.1.x86_64.rpm","Release":"2025-09-17T16:34:05","Revision":"K","SHA1Sum":"a863f245cc83156c5f290a12833bd29bf069c597","SHA256Sum":"5148e77422f8b104d73815c96c0a7c76930ded77cac2774914fc246b64bcb752","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041479.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB008000JWRTD ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000JWRTD","TargetGUID":"4d2340a5-3042-3830-3030-304a57525444","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T18:35:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RHEL 10のサポートを追加しました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1b5d3a6032d24d3183a0c45f7a3a0c94"}]},{"ProductId":"91adee7c0766499184ce8d25a925669e","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image.","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"IEGen10_0.2.3.0.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16802814","DateModified":"2022-07-14T09:25:35","FileList":["IEGen10_0.2.3.0.signed.bin","IEGen10_0.2.3.0.xml","IEGen10_0.2.3.0_B.signed.bin","payload.json"],"MD5Sum":"110d8fc38adb8d242bb703af9f537e4e","Name":"IEGen10_0.2.3.0.fwpkg","Release":"2022-07-14T09:22:01","Revision":"B","SHA1Sum":"cb3c2e94d23660857fe9f66cd398cfa93454481e","SHA256Sum":"3e9cd8f8c2f5ff32c0afb8cf840fba61ddc6b3fb7185bcf19930f90d32288517","Size":"16MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers"},{"Lang":"ja","Value":"ROMフラッシュ ファームウェアパッケージ - HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2022-08-14T09:18:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>なし</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし        </p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。一部のシステムでは、これによりCPU使用率が一時的に低下したり、ネットワークトラフィックの持続が1秒未満になる可能性があります。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"}],"SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"40c0e7a8438342b484e5d401d21392eb"}]},{"ProductId":"3eab1bf1c35b40e5b35b9f8cbcf441cd","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp068010.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2453670","DateModified":"2025-11-26T03:42:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1/CP069831.xml","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1/cp068010.compsig","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1/cp068010.zip","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069831.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069831.scexe"],"MD5Sum":"5488c57993cc0327aaca024651ee6c4f","Name":"firmware-ml30gen10plus_me-06.00.03.708-2.1.x86_64.rpm","Release":"2025-11-26T09:35:04","Revision":"B","SHA1Sum":"1d238aa23e6394e0f3f2b059730644d334368fed","SHA256Sum":"4adfb532081c903654393b5608842d44de83536f17878d418ed026477f6e4c64","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant ML30 Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-26T09:30:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance. This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance. This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance. This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance. This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e0fba97ca42145fda634f826ffe76d57"}]},{"ProductId":"794cbcecc16344ce8539a9b80f70c157","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2025で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1079272","DateModified":"2025-11-14T07:53:16","FileList":["cp069521.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"d7b80c8cf0aae900c08fbcc33d5e6912","Name":"cp069521.exe","Release":"2025-11-14T07:39:04","Revision":"B","SHA1Sum":"0173147547c8c3cbd37a36d87cb27ca1315f72d7","SHA256Sum":"006c412c6ed4ed7a9bf431c360d2216600183725e376c1734a4213bb2717c108","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.1.24.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel E1R Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Intel E1Rドライバー for Windows Server 2025"},{"Lang":"cn","Value":"HPE Intel E1R Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T06:37:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>機能変更: E1Rドライバーからの仮想化の削除。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"cn"}],"Version":"14.1.24.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>機能変更: E1Rドライバーからの仮想化の削除。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Feature Change: Removal of virtualization from E1R driver.</p>","Lang":"cn"}],"Version":"14.1.24.0"}],"SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"f339b773d97449db8bc0d1ac2bda4459"}]},{"ProductId":"fcd35b42a2c44c87b93ab943ca8d2f70","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"ja","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 10."},{"Lang":"cn","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 10."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"17867805","DateModified":"2025-07-16T07:07:03","FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"MD5Sum":"e2ead26d77707f3df2f97851fc9eba66","Name":"kmod-qlgc-fastlinq-8.76.2.0-12.rhel10u0.x86_64.rpm","Release":"2025-07-16T06:51:31","Revision":"","SHA1Sum":"805893c8d20c8bc298d0cf01ca400947680156e8","SHA256Sum":"7c1a38a6fe36bd1e6eaca60060003a91c40d234ef43de2caa616329b3b22bcc9","Size":"17MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.2.0-12"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 10"},{"Lang":"ja","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 10"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770070","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770069","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770068","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770071","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770072","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770074","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770073","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-16T06:48:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.76.2.0-12"}],"SWKeys":[{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"db3f275d299745b19452ac0b19b733f4"}]},{"ProductId":"3fa689b1e0c54064af40f5128fac0e5b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"}],"Files":[{"Bytes":"20143593","DateModified":"2025-03-06T08:36:35","FileList":["/CP066011_BUILD_3.data","/CP066011.vmexe64","/CP066011.vmfile","/CP066011_VMw.zip","/CP066011.xml","/payload.json","/CP066011_VMw.zip/index.xml","/CP066011_VMw.zip/vendor-index.xml","/CP066011_VMw.zip/metadata.zip","/CP066011_VMw.zip/vib20/CP066011/HPE_bootbank_CP066011_HPG2.3-1OEM.800.1.0.20613240.vib","/CP066011_VMw.zip/metadata.zip/vendor-index.xml","/CP066011_VMw.zip/metadata.zip/vmware.xml","/CP066011_VMw.zip/metadata.zip/vibs/CP066011-8229392492772987063.xml","/CP066011_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066011_HPG2.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"8151e04ea795196fc8a3b0ea5035b80d","Name":"CP066011.zip","Release":"2025-03-06T08:35:46","Revision":"J","SHA1Sum":"ada8c11567f54026cd836c09600f3687e9d1e772","SHA256Sum":"e3b82881aa3456b96ecf36ae7e520762ff223de9507990ceceeda7faaf0cd940","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2","VibList":[{"Name":"CP066011","Version":"HPG2.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041453.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: . ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: . ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000GWRTN","TargetGUID":"4d2340a5-3042-3431-3030-30475752544e","Type":"sata"},{"Id":"MB012000GWRTL","TargetGUID":"4d2340a5-3042-3231-3030-30475752544c","Type":"sata"},{"Id":"MB010000GWRTK","TargetGUID":"4d2340a5-3042-3031-3030-30475752544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:10:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6fcc9abfdf734302bb9d64b076e28505"}]},{"ProductId":"e01aaedc1c6c4e4090054a22e89562d4","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Management"},{"Lang":"ja","Value":"ソフトウェア - マネジメント"},{"Lang":"cn","Value":"软件 - 管理"}],"Description":[{"Lang":"en","Value":"The HPE iLO Driver allows software to communicate with the iLO management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities. "},{"Lang":"ja","Value":"HPE iLOドライバーを使用することで、ソフトウェアとiLO マネジメントコントローラーの通信が可能になります。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"},{"Lang":"cn","Value":"The HPE iLO Driver allows software to communicate with the iLO management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"21816","DateModified":"2025-11-21T16:08:53","FileList":["/cp068902.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/index.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/vendor-index.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/vib20/ilo/HPE_bootbank_ilo_800.10.9.1.4-1OEM.800.1.0.20613240.vib","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/ilo--1061765975396018296.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"d3cecb1aa0052c8715313550d95c8c68","Name":"cp068902.zip","Release":"2025-11-21T16:08:41","Revision":"","SHA1Sum":"1994715f281ee3e85778b1331b952cba5d12e551","SHA256Sum":"438263d20d96e0287ac255082f12d03d2e7b75c61a9297da6846ed6eb95b2039","Size":"21KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec948d20a3","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"ilo","Version":"800.10.9.1.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p><ol><li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li><li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li><li>Mount the USB key on a remote server running Windows or Linux.</li><li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li><li>Select the &quot;next&quot; button.</li><li>Click &quot;Add Single Target.&quot;</li><li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li><li>Enter the ESXi host credentials (root or administrator username and password).</li><li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li></ol><p><br /><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"ja","Value":"<p><strong>Service Pack for ProLiant (SPP)からSmart Update Manager (SUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p><ol><li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li><li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li><li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li><li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li><li>「次へ」ボタンを選択します。</li><li>「シングルターゲットの追加」をクリックします。</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li><li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li><li>Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li></ol><p><br /><strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li><li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li></ol><p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p><ol><li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li><li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li><li>Mount the USB key on a remote server running Windows or Linux.</li><li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li><li>Select the &quot;next&quot; button.</li><li>Click &quot;Add Single Target.&quot;</li><li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li><li>Enter the ESXi host credentials (root or administrator username and password).</li><li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li></ol><p><br /><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE iLO Driver Bundle Smart Component for ESXi 8.0 and ESXi 9.0"},{"Lang":"ja","Value":"HPE iLOドライバーバンドルSmartコンポーネントfor ESXi 8.0およびESXi 9.0"},{"Lang":"cn","Value":"HPE iLO Driver Bundle Smart Component for ESXi 8.0 and ESXi 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"22"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-12T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>The product addressed a probabilistic PSOD when repeatedly doing the OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、OSの再起動を繰り返し実行した場合に発生する確率的な PSOD に対処しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>The product addressed a probabilistic PSOD when repeatedly doing the OS reboot.</li></ul>","Lang":"cn"}],"Version":"2025.01.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Implement MSI interrupt in the ilo driver&nbsp;to fix PSOD due to interrupt storm and to fix snmpwalk delays.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Implement MSI interrupt in the ilo driver&nbsp;to fix PSOD due to interrupt storm and to fix snmpwalk delays.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Implement MSI interrupt in the ilo driver&nbsp;to fix PSOD due to interrupt storm and to fix snmpwalk delays.</p>","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"ilo-driver:800.10.9.1.4-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ilo:800.10.9.1.4-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c0411cf9fc97412eb6542bb54c8f589d"}]},{"ProductId":"e0d3905a13b74f06a63b96091e3a0b13","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3630-3030-304759444e4c","Version":"HPG4"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3830-3030-304759445045","Version":"HPG4"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3031-3030-304759444e4e","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB006000GYDNL, MB008000GYDPE and MB010000GYDNN"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB006000GYDNL、MB008000GYDPE、およびMB010000GYDNN"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB006000GYDNL, MB008000GYDPE and MB010000GYDNN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; Firmware changes aligned for FIPS code release and one assert fix</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; Firmware changes aligned for FIPS code release and one assert fix</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; Firmware changes aligned for FIPS code release and one assert fix</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2623297","DateModified":"2025-06-20T01:35:14","FileList":["payload.json","Seagate_CimarronBP_SCIMARBPETG4.HPb","Seagate_CimarronBP_SCIMARBPETG4.xml"],"MD5Sum":"a5dbf6b0bb046c957f31547e1d8518c7","Name":"Seagate_CimarronBP_SCIMARBPETG4.fwpkg","Release":"2025-06-20T01:32:29","Revision":"","SHA1Sum":"842440cd46a3b456897604f5efb5a636c98ce85d","SHA256Sum":"1380d55773ddcd4828e2d6388a5be330499d38c17c8d9ba9a58c4ef2c4c4df1c","Size":"2MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304759444e4c","4d2340a5-3042-3830-3030-304759445045","4d2340a5-3042-3031-3030-304759444e4e"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB006000GYDNL, MB008000GYDPE and MB010000GYDNN"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ -MB006000GYDNL、MB008000GYDPE、およびMB010000GYDNN"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB006000GYDNL, MB008000GYDPE and MB010000GYDNN"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB006000GYDNL","TargetGUID":"4d2340a5-3042-3630-3030-304759444e4c","Type":"sata"},{"Id":"MB008000GYDPE","TargetGUID":"4d2340a5-3042-3830-3030-304759445045","Type":"sata"},{"Id":"MB010000GYDNN","TargetGUID":"4d2340a5-3042-3031-3030-304759444e4e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-20T00:30:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>1) Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2) Adding other logging and FW enhancements.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>1) ドライブがアサートを防ぐためにRequest Senseの前にR/Wコマンドを選択して実行する原因となった、メディアキャッシュクリーニングの中止処理のロジックバグを修正しました。<br />2) その他のログ機能とFW機能強化を追加します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>1) Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2) Adding other logging and FW enhancements.</p>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for FIPS code release and one assert fix</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for FIPS code release and one assert fix</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware changes aligned for FIPS code release and one assert fix</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB006000GYDNL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB008000GYDPE","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB010000GYDNN","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"0be86abeb599456ea5c1845fc69ef581"}]},{"ProductId":"ec9be2d62b6d4bb78b41f4e500d70240","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"HPE Smart Array and Smart RAID controller driver component for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE SmartアレイおよびSmart RAIDコントローラードライバーコンポーネントfor VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE Smart Array and Smart RAID controller driver component for VMware vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"350690","DateModified":"2025-12-23T07:01:34","FileList":["/cp069363.xml","/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.zip","/MIS_bootbank_smartpqi_90.4880.0.109-1OEM.900.0.24755229.vib","/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.zip/index.xml","/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.zip/vendor-index.xml","/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.zip/metadata.zip","/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.zip/vib20/smartpqi/MIS_bootbank_smartpqi_90.4880.0.109-1OEM.900.0.24755229.vib","/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.zip/metadata.zip/vibs/smartpqi--8160089740883774075.xml","/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Microchip-smartpqi_90.4880.0.109-1OEM.900.0.24755229.xml"],"MD5Sum":"3d9836d0303e0020bca28bb10b8bcd01","Name":"cp069363.zip","Release":"2025-12-23T07:00:19","Revision":"","SHA1Sum":"5778c061dd22c4c349e2f44218dfbbf636ad36f6","SHA256Sum":"14a44979c762c8daf2e68b4d8ce919080815207dfa2937872730261654ae8560","Size":"342KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c","20a6e8e4-bf33-4c71-a6bf-d9ec72979cda"],"TypeOfChange":"1","Version":"2026.01.01","VibList":[{"Name":"smartpqi","Version":"90.4880.0.109-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hp/swpackages and ./hpsum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul><p><br />&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p><p><strong>リモートオンライン：</strong></p><ul><li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li><li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li><li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li><li> CD /hp/swpackagesおよび./hpsum</li><li> 次へボタンを選択します。</li><li> シングルターゲットの追加をクリックします。</li><li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li><li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li> Smart Update Managerの指示に従ってアップデートを行います。</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ul><li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li><li> VUMおよびesxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</li></ul><p><br /> </p>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hp/swpackages and ./hpsum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul><p><br />&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 9.0 (Driver Component)."},{"Lang":"ja","Value":"HPE ProLiant Gen10 SmartアレイおよびGen10 PlusおよびGen11 Smart RAIDコントローラードライバーfor VMware vSphere 9.0 (ドライバーコンポーネント)"},{"Lang":"cn","Value":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 9.0 (Driver Component)."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T09:43:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed PSOD indicates a divide-by-zero happened.&nbsp;</li><li>Fixed an issue where the driver&#39;s controller structure field was too small for the full ASCII firmware version.&nbsp;</li><li>Fixed an issue where a message from a periodic check on the controller heartbeat appeared as a&nbsp;system error instead of an informational message.&nbsp;</li><li>Fixed an issue where firmware versioning information was incorrect or blank on some of the controllers.&nbsp;</li><li>Fixed an issue where in a specific scenario, the device removal handler attempts to remove a device that has already been removed by the normal device discovery flow.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ゼロ除算が発生したことを示すPSODを修正しました。 </li><li>ドライバーのコントローラー構造フィールドが完全なASCIIファームウェアバージョンに対して小さすぎる問題を修正しました。 </li><li>コントローラーのハートビートの定期チェックからのメッセージが情報メッセージではなくシステム エラーとして表示される問題を修正しました。 </li><li>一部のコントローラーでファームウェアのバージョン情報が間違っていたり空白だったりする問題を修正しました。 </li><li>特定のシナリオにおいて、デバイス削除ハンドラーが、通常のデバイス検出フローによってすでに削除されているデバイスを削除しようとする問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed PSOD indicates a divide-by-zero happened.&nbsp;</li><li>Fixed an issue where the driver&#39;s controller structure field was too small for the full ASCII firmware version.&nbsp;</li><li>Fixed an issue where a message from a periodic check on the controller heartbeat appeared as a&nbsp;system error instead of an informational message.&nbsp;</li><li>Fixed an issue where firmware versioning information was incorrect or blank on some of the controllers.&nbsp;</li><li>Fixed an issue where in a specific scenario, the device removal handler attempts to remove a device that has already been removed by the normal device discovery flow.</li></ul>","Lang":"cn"}],"Version":"2025.09.01"},{"ReleaseNotes":[{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>SR 2.10.2/SR 3.5.2 RC</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2026.01.01"}],"SWKeys":[{"Name":"Microchip-smartpqi:90.4880.0.109-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"smartpqi:90.4880.0.109-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2087ae0c509a4375b1e87fbc7bc1c3d4"}]},{"ProductId":"4b7bb75be74941e8987c342978cb18f9","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57416 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957416A4162HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41593","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957416A4162HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Version":"235.1.164.14"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM235.1.164.14_BCM957416A4162HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Version":"235.1.164.14"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57416 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57416 Gigabit Ethernet NIC firmware."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57416 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 235.1.164.14&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.12<br />&nbsp;</td><td colspan=\"1\" rowspan=\"3\">235.1.164.2<br />&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"1602328","DateModified":"2025-12-11T09:37:13","FileList":["BCM235.1.164.14_BCM957416A4162HC.HPb","BCM235.1.164.14_BCM957416A4162HC.xml","payload.json"],"MD5Sum":"88d1bfe56af8b7289856445bf6d2ec4a","Name":"BCM235.1.164.14_BCM957416A4162HC.fwpkg","Release":"2025-12-11T09:33:42","Revision":"","SHA1Sum":"484073c525454444d2f7b581bbe18166f3739195","SHA256Sum":"e626c239619187837941532ec6e1a041639f4b67d0a66f051ca4fa8059bc0c75","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM57416 adapter"},{"Lang":"ja","Value":"Broadcom Firmware Package for BCM57416 adapter"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM57416 adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-11T08:07:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"en"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhancement enables a self-shutdown feature to prevent overheating when certain monitoring features are disabled.&nbsp;<br />It applies only to newer hardware that originally shipped with firmware version 223.1.135.7 or higher and is not enabled on earlier revisions.</p>","Fixes":"<ul><li>This product fixes the issue where the firmware version details failed to update and the card showed as not operational after upgrading BCM5741x adapters&nbsp;</li><li>This product fixes the issue where failed to detect a 10GBASE-LR SFP+ causing incorrect defaults and a link failure.</li><li>This product fixes the issue where iLO BMC shared &nbsp;IP on OCP NIC, link flap occurred during OS reboot.</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"BCM_NXE_57416_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"2b556b376e864c61a79dc8d808bc1e3e"}]},{"ProductId":"7ead0459ae26493fa240dac6ad17d606","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8002"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1908"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 8.0."},{"Lang":"ja","Value":"このパッケージには、ESXi 8.0上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1908</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1908</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.8002</td><td>MT_0000000417</td></tr></tbody></table>"}],"Files":[{"Bytes":"28938957","DateModified":"2025-10-14T07:14:33","FileList":["/CP068978.vmexe64","/CP068978.vmfile","/payload.json","/CP068978_VMw.zip","/CP068978.xml","/CP068978_VMw.zip/index.xml","/CP068978_VMw.zip/vendor-index.xml","/CP068978_VMw.zip/metadata.zip","/CP068978_VMw.zip/vib20/CP068978/HPE_bootbank_CP068978_1.0.0-8.0.0.21495797.vib","/CP068978_VMw.zip/metadata.zip/vendor-index.xml","/CP068978_VMw.zip/metadata.zip/vmware.xml","/CP068978_VMw.zip/metadata.zip/vibs/CP068978-369091245645843139.xml","/CP068978_VMw.zip/metadata.zip/bulletins/Smart-Component-CP068978_1.0.0-8.0.0.21495797.xml"],"MD5Sum":"96c6e8b20987014a413e79f59b37f226","Name":"CP068978.zip","Release":"2025-10-14T07:14:24","Revision":"","SHA1Sum":"503cefe3fa55178ac666cba251702470037c19e7","SHA256Sum":"0150eae42059371c0730bdd5a7a6e591ae3f4318a6b99c880005546abfdeb877","Size":"27MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.7","VibList":[{"Name":"CP068978","Version":"1.0.0-8.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記</strong>：SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください： </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します  <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for Mellanox Open Ethernet cards"},{"Lang":"ja","Value":"Mellanox Open Ethernetカード用オンラインファームウェアアップグレードユーティリティ（ESXi 8.0）"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for Mellanox Open Ethernet cards"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-29T06:25:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4506:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>P21930-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4121A-XCATアダプター)</li><li>P11341-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4621A-ACAB OCP3アダプター)</li></ul><p> </p><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>P21927-B21（HPE Ethernet 100Gb 2ポートQSFP28 MCX516A-CCHTアダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4506で修正されました：</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4506:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.6"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.8002:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />&nbsp;</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br /><br />&nbsp;</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong><br /><br /><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.7"}],"SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bf6ea1549af04f4cbc89af0a38a94a6d"}]},{"ProductId":"1012a84c719148b1b9e7357e885d2199","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.624.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"ja","Value":"HPE Storageファイバーチャネル（FC）アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター（HBA）ドライバーを提供する、バージョン14.4.624.0 のEmulex Storportドライバーfor Extended Systemが含まれています。"},{"Lang":"cn","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.624.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4292480","DateModified":"2025-11-24T08:37:17","FileList":["cp066305.xml","cpqsetup.exe","elxdrvr-fc-14.4.624.0-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"MD5Sum":"ec24829d940b7fa17875150fae46f2ac","Name":"cp066305.exe","Release":"2025-11-24T08:35:46","Revision":"","SHA1Sum":"80fbab93dc1d8d22d7936d2ad064fd8b20ae1fcd","SHA256Sum":"b65d9f8d820eeb9444e86afee9ecdecafbc1fe6eef7bcd0d3b63162c0fe3f153","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.624.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p> </p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2025"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T12:12:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.393.20にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.393.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.624.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.624.0にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>    elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.624.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.624.0"}],"SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"033a9645c66c47ef8b86aec84e0f5f23"}]},{"ProductId":"ccde97956825448f97ee8427bc2eccdb","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Controller"},{"Lang":"ja","Value":"ソフトウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"软件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The HPE Smart Array SR Event Notification Service provides event notification to the 64-bit Microsoft Windows Server system event log for systems using the HPE Smart Array SR controller driver."},{"Lang":"ja","Value":"HPE SmartアレイイSRベント通知サービスは、HPE SmartアレイSRコントローラードライバーを使用しているシステムで、64ビットMicrosoft Windows Serverシステムイベントログへのイベント通知をサポートします。"},{"Lang":"cn","Value":"The HPE Smart Array SR Event Notification Service provides event notification to the 64-bit Microsoft Windows Server system event log for systems using the HPE Smart Array SR controller driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"743560","DateModified":"2025-11-17T13:14:15","FileList":["cp067917.xml","cpqsetup.exe","hpepqiesrv.dll","hpepqiesrv.exe","hpepqiesrv.msi"],"MD5Sum":"1351620562d46259cc6b117001aebbf2","Name":"cp067917.exe","Release":"2025-11-17T13:12:04","Revision":"D","SHA1Sum":"8e236b7c21bf411031e0a6bc878b1f598742fa17","SHA256Sum":"d24504e9f532e4921eb3bf54c9755aa2c30831e447c070eadf5482fe84a1d58d","Size":"726KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec74b19684"],"TypeOfChange":"1","Version":"1.2.1.69"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/verbose_log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59","SWKey":"SmartDQa.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"62.0.28.64"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Smart Array SR Event Notification Service for Windows Server 64-bit Editions"},{"Lang":"ja","Value":"HPE SmartアレイSRイベント通知サービス for Windows Server 64ビットEditions"},{"Lang":"cn","Value":"HPE Smart Array SR Event Notification Service for Windows Server 64-bit Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0655","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0655","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0701","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0701","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-23T06:25:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Fixed online force flash issue on OneView.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>OneViewでのオンライン強制フラッシュの問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Fixed online force flash issue on OneView.</p>","Lang":"cn"}],"Version":"1.2.1.69"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"<ul><li>Fix windows tool cert expire issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"<ul><li>Fix windows tool cert expire issue.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"<ul><li>Fix windows tool cert expire issue.</li></ul>","Lang":"cn"}],"Version":"1.2.1.69"}],"SWKeys":[{"Name":"hpepqiesrv.exe","SWKeyExpectedPath":"%programfiles%\\hpe\\hpepqiesrv"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"9ebffb2cdb5344b9b7b9694171275a05"}]},{"ProductId":"5f09aeda85cb45139823fad0b151d05f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Provides proactive protection against contamination built up on the media and air-bearing surface of the heads by increased routine &ldquo;sweeping&rdquo; of the media surface.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Provides proactive protection against contamination built up on the media and air-bearing surface of the heads by increased routine &ldquo;sweeping&rdquo; of the media surface.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3542228","DateModified":"2025-08-02T22:47:27","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-1.1/CP067391.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-1.1/TA14SXn0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067391.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067391.scexe"],"MD5Sum":"22511691c9d2715901f45bdba53e5aac","Name":"firmware-hdd-8d68452816_0HPD9-1.1_amd64.deb","Release":"2025-08-03T03:41:17","Revision":"","SHA1Sum":"00e0ff8e60b40c008312b6b4d8971dc2564810af","SHA256Sum":"ac9e75a5aea3f84bf332acffc0ccf9b305536073a91e344334fa6c172fc53321","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP041672.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000300JWHPL","TargetGUID":"452340a5-3048-3030-3330-304a5748504c","Type":"sas"},{"Id":"EH000600JWHPN","TargetGUID":"452340a5-3048-3030-3630-304a5748504e","Type":"sas"},{"Id":"EH000900JWHPP","TargetGUID":"452340a5-3048-3030-3930-304a57485050","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:33:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves overall drive performance.</li><li>The risk of not upgrading to this firmware is the increased possibility of Drive hang-up in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4cbc796f99074286878645e8ed5a92bc"}]},{"ProductId":"840d26617d5744de973393a116bf720d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3499312","DateModified":"2025-11-15T14:50:21","FileList":["4ICRHPK3.rel","cp068623.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"9bcdfba373ba70feb38b5b60facf0140","Name":"cp068623.exe","Release":"2025-11-15T14:45:31","Revision":"I","SHA1Sum":"6963bfbdefad95ee3eea3300a7a644285f15aad5","SHA256Sum":"e6a1df1c99d03f92f07b0fc9bf13fba7dd3d60d351e4201342752f9439f6b9a2","Size":"3MB","TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MO006400KWVVA","TargetGUID":"4d2340a5-304f-3630-3430-304b57565641","Type":"nvme"},{"Id":"VO004000KWVUR","TargetGUID":"562340a5-304f-3430-3030-304b57565552","Type":"nvme"},{"Id":"MO003200KWVUV","TargetGUID":"4d2340a5-304f-3330-3230-304b57565556","Type":"nvme"},{"Id":"VO002000KWVVC","TargetGUID":"562340a5-304f-3230-3030-304b57565643","Type":"nvme"},{"Id":"MO001600KWVUU","TargetGUID":"4d2340a5-304f-3130-3630-304b57565555","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T07:23:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"}],"SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c3565c0707884cfd8788bdb7d13f3b49"}]},{"ProductId":"b00b4afad66b4dd386d098e91550601d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP6."},{"Lang":"ja","Value":"この製品は、SUSE Linux Enterprise Server 15 SP6下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"},{"Lang":"cn","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP6."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"42254","DateModified":"2025-12-12T07:07:15","FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-235.1.164.14.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"MD5Sum":"603665582ba1a02854269a7fb2d0205d","Name":"libbnxt_re-235.1.164.14-sles15sp6.x86_64.rpm","Release":"2025-12-12T07:05:06","Revision":"","SHA1Sum":"89b579bdf26270cf1dcf2eab595487626a222160","SHA256Sum":"9df1067116be549211cecf378d9eaca5f02b75e338e0dcd73bf415935ec0fab4","Size":"41KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"ja","Value":"<p style=\"text-align:left\">rpm -ivh <bnxt_rooce >.rpm</p>"},{"Lang":"cn","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP6"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E RoCEライブラリfor SUSE Linux Enterprise Server 15 SP6"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP6"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-12T04:04:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul style=\"list-style-type:disc\"><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"235.1.164.14"}],"SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"980bc003e1324c0089fc7f56d030bb97"}]},{"ProductId":"b88ebb63a68747808884160b11c000eb","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"853784","DateModified":"2025-11-16T03:19:21","FileList":["cp069556.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs68x64.cat","vxs68x64.din","vxs68x64.inf","vxs68x64.sys","vxsmsg.dll"],"MD5Sum":"c7cff9dee36855ef1fbdf2c81c206bce","Name":"cp069556.exe","Release":"2025-11-16T03:05:05","Revision":"B","SHA1Sum":"baf16b649044aab51fd3ea31b8a0ddfc936f26b6","SHA256Sum":"192b9b64b9ca65fc4cbe9d09ef858150a81edfa31c0886e3af3ab87789925086","Size":"833KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf6d17a48"],"TypeOfChange":"1","Version":"2.1.252.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel vxs Driver for Windows Server 2019"},{"Lang":"ja","Value":"Windows Server 2019用HPE Intel vxsドライバー"},{"Lang":"cn","Value":"HPE Intel vxs Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1565","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d1","Type":"pci","Ven":"8086"},{"Dev":"1564","Type":"pci","Ven":"8086"},{"Dev":"1565","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d2","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、新しいファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.252.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、新しいファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.252.0"}],"SWKeys":[{"Name":"vxs68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"0e275b595b61436795ae02fc509d51c6"}]},{"ProductId":"84e7c2b1f88e4ba3ad8fe3ec63fe5a60","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8002"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1908"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 9.0."},{"Lang":"ja","Value":"このパッケージは、ESXi 9.0.上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"}],"Files":[{"Bytes":"23334386","DateModified":"2025-10-15T06:55:38","FileList":["/CP069156.xml","/CP069156_VMw.zip","/payload.json","/CP069156.vmexe64","/CP069156.vmfile","/CP069156_VMw.zip/index.xml","/CP069156_VMw.zip/vendor-index.xml","/CP069156_VMw.zip/metadata.zip","/CP069156_VMw.zip/vib20/CP069156/HPE_bootbank_CP069156_1.0.2-1OEM.900.0.24755229.vib","/CP069156_VMw.zip/metadata.zip/vendor-index.xml","/CP069156_VMw.zip/metadata.zip/vmware.xml","/CP069156_VMw.zip/metadata.zip/vibs/CP069156-7195023491594710810.xml","/CP069156_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069156_1.0.2-1OEM.900.0.24755229.xml"],"MD5Sum":"b5ca75e44b7b23aad0f1cea811656b8e","Name":"CP069156.zip","Release":"2025-10-15T07:08:01","Revision":"","SHA1Sum":"9c08cc06fe46b4aa39d25327e015f085f4f9a91e","SHA256Sum":"ee1d1f407d26ee7d4c6a1b45b5f74908e553e36984b7d357d97fa794221c6d1f","Size":"22MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.2","VibList":[{"Name":"CP069156","Version":"1.0.2-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記</strong>：SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションにアダプターの正確な名前が表示されません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください： </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します  <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE Mellanox Ethernet only adapters"},{"Lang":"ja","Value":"HPE Mellanox Ethernetアダプター専用のオンラインファームウェアアップグレードユーティリティ(ESXi 9.0)"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE Mellanox Ethernet only adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T10:50:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2ポート640FLR-SFP28アダプター)</li><li>817753-B21 (HPE Ethernet 25Gb 2ポート640SFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>874253-B21（HPE Ethernet 100Gb 1ポート842QSFP28アダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4506で修正されました：</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.2"}],"SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"dab819845e2c416f9615b377a41a073e"}]},{"ProductId":"e94dfd89626f4fc992d59a1c00e08f54","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB006000GWJRRおよびMB008000GWJRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;-&nbsp;MB006000GWJRR and MB008000GWJRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;-&nbsp;MB006000GWJRR and MB008000GWJRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3276576","DateModified":"2025-11-15T10:23:16","FileList":["cp068755.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG06ACHPG6.REL"],"MD5Sum":"75c5c4f1d693a18b7fd4864098a7c829","Name":"cp068755.exe","Release":"2025-11-15T10:18:39","Revision":"E","SHA1Sum":"cc2c8c496b4f8a81b72dff444491b102b404631e","SHA256Sum":"1232aaa1c1f0ad62e08629437e188125e6711e22c7cef9cfc53927ce53d065dd","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000GWJRT","TargetGUID":"4d2340a5-3042-3830-3030-3047574a5254","Type":"sata"},{"Id":"MB006000GWJRR","TargetGUID":"4d2340a5-3042-3630-3030-3047574a5252","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:49:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"88b39410f2fd41e3a7c608a38833448d"}]},{"ProductId":"d3e8a053234f49d9a3735931f34c77c7","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U43_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.72 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9031279","DateModified":"2026-01-13T01:18:17","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.72_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.72_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.72_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.72_2026_01_09-1.1/CP070191.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.72_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.72_2026_01_09-1.1/U43_3.72_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.72_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.72_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.72_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070191.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070191.scexe"],"MD5Sum":"40974201b47dc9e07c86cc6905cffb72","Name":"firmware-system-u43-3.72_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T07:10:56","Revision":"","SHA1Sum":"7b15fdaaaeb50c1a4feda6a4773436136836346b","SHA256Sum":"ec0d5078be83f8e0a392ca73d6f1691fbcd79cbb3a3f1f4ed4077eb56b1d5516","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.72_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"ja","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T09:35:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.103と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.70_08-08-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_01-09-2026"}],"SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7a009f7d37bd48e2b15d13ee77a2c902"}]},{"ProductId":"954c63f35d4743b2b629b5d17bfd860b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"ja","Value":"このコンポーネントには、HPE Storageアレイのためのファイバーチャネルホストバスアダプタードライバーサポートを提供する、QLogic Storportドライバーバージョン9.4.11.20が含まれています。"},{"Lang":"cn","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1727152","DateModified":"2026-01-05T06:40:18","FileList":["cp066324.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"MD5Sum":"57ebbfc82abc6382dedc0cf9825f0bca","Name":"cp066324.exe","Release":"2026-01-05T06:38:07","Revision":"b","SHA1Sum":"dd17594d6ac6ad02d15bd46e65a1f5e268a552a6","SHA256Sum":"66139d1852e2f8e0a06f9808e489bd972522607c3babf77282bf220a5c98dcd3","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />[インストール]ボタンをクリックして、インストールを開始します。<br />"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"HPE Storage ファイバーチャネルアダプターキットfor x64 QLogic Storportドライバーfor Microsoft Windows Server 2025"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T14:55:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This is the first driver for Windows 2025 . The driver version is 9.4.11.20.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>これは Windows 2025 用の最初のドライバーです。このドライバーのバージョンは9.4.11.20です、</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This is the first driver for Windows 2025 . The driver version is 9.4.11.20.</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"},{"ReleaseNotes":[{"Enhancements":"<p>This is the first driver for Windows 2025 . The driver version is 9.4.11.20.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>これは Windows 2025 用の最初のドライバーです。このドライバーのバージョンは9.4.11.20です、</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This is the first driver for Windows 2025 . The driver version is 9.4.11.20.</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"}],"SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5652edae891844e78f5039b595ec4a61"}]},{"ProductId":"3f857d7b01734aa494f8146516002d2e","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR416i-p_Gen10P_52.32.3-6333_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.32.3-6333"}]},"MinimumActiveVersion":"52.26.3.5487","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"HPE MR416i-p Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE MR416i-p Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"ja","Value":"<p>One-buttonセキュア消去（OBSE）およびオンラインファームウェアアクティベーション（OFA）はHPE Gen10サーバーではサポートされていないため、MR Gen10 plusコントローラーはGen10サーバーでのオンラインファームウェアアップデートをサポートしません。<br />HPE Gen10サーバーにFWPKGをインストールする必要がある場合は、FWPKGをフラッシュした後に再起動が必要になることを想定してください。</p>"},{"Lang":"cn","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"}],"Files":[{"Bytes":"7514246","DateModified":"2025-08-19T15:35:21","FileList":["HPE_MR416i-p_Gen10P_52.32.3-6333_A.HPb","HPE_MR416i-p_Gen10P_52.32.3-6333_A.xml","payload.json"],"MD5Sum":"287bd9e100a67976b31459fd014b0a7b","Name":"HPE_MR416i-p_Gen10P_52.32.3-6333_A.fwpkg","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"209b7a11a8091862fa731bbf413fca1b7346c67a","SHA256Sum":"887fdd1fcd90962e03da7af9d51225d0ae5383a176cd161807d4fd7f67930736","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e215900293"],"TypeOfChange":"1","Version":"52.32.3-6333"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/connect/s/product?language=en_US&kmpmoid=7630408&tab=driversAndSoftware&driversAndSoftwareFilter=8000078\">RESTfulインターフェイスツール</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p><p>iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li></ul>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE MR416i-p Gen10 Plus Tri Mode Controller "},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE MR416i-p Gen10 Plusトライモードコントローラー "},{"Lang":"cn","Value":"Firmware Package - HPE MR416i-p Gen10 Plus Tri Mode Controller "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T18:04:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfish デバイス有効化の機能強化<ul><li>Redfishボリューム変換サポート<ul><li>POST #Volume.ChangeRAIDLayout: RAIDレイアウトの変更。RAIDレイアウトの変更は、入力JSONボディにターゲットRAIDTypeとドライブのリストを提供することで実現されます。</li><li>POST #Volume.ChangeRAIDLayout: サイズ変更。ChangeRAIDLayoutを使用すると、RAIDTypeを変更せずに新しい未構成正常ドライブを追加することでボリュームのサイズを変更できます。このような場合、入力JSONボディでRAIDTypeを指定してはいけませんが、それに応じて完全なドライブリストを指定する必要があります。</li><li>PATCH Volume[CapacityBytes]: この操作は、ボリューム内に利用可能な未使用サイズがある場合にボリュームのサイズを変更するために使用されます。ここに新しいドライブを追加するスコープはありません</li><li>POST #Volume.CheckConsistency: この操作は、ボリューム上の整合性チェック操作を開始します。この操作では入力は想定されません。</li></ul></li><li>Redfish Metrics GETサポート<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount、CorrectableECCErrorCount、CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount、SAS.LossOfDwordSynchronizationCount、SAS.RunningDisparityErrorCount、PCIeErrors.CorrectableErrorCount、PCIeErrors.FatalErrorCount、PCIeErrors.NonFatalErrorCount</li><li>各カウンターは最大65535までの値を保持できます。カウンターが最大値に達しても、値はリセットされません。</li><li>ユーザーがコントローラーのNVRAMクリアまたはRedfish ResetToDefaults.ResetAllを実行すると、メトリックはクリアされます。</li></ul></li></ul></li><li>MRSAおよびstorcli工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加。<ul><li>コントローラー上に構成が存在する場合、または固定キャッシュが存在する場合、NVRAMクリア操作は許可されません。</li><li>NVRAMをクリアした後、コントローラーFWはオンラインコントローラーリセット (OCR) を実行します。何らかの理由でOCRを実行できない場合は、システムを再起動するようにユーザーに通知されます。</li><li>NVRAMクリア操作は、機能的にはRedfish ResetToDefaults.ResetAll操作と同等です。</li></ul></li><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。非ホットプラグ構成の場合、コントローラーは常に16個のベイを表示します。</li></ul>","Fixes":"<ul><li>a00143124en_usアドバイザリを修正: HPE MR Gen11 コントローラー - HPE Gen11サーバー上のMR Gen11コントローラーがIMLで\"WriteCacheDataLoss\"を生成できない場合がある</li><li>a00148035en_usアドバイザリを修正: HPE MR Gen11コントローラー - ベイとボックスのNVMeドライブの場所がワンタイムブートメニューに表示されない</li><li>Linux OSでLTOの128KBを超える読み取り/書き込み転送が失敗する問題を修正</li><li>Backup ExecがLTOで動作しない問題を修正</li><li>240個の論理ドライブが構成されている場合、サーバーのブート時にコントローラーがiLOによってドロップされる可能性がある問題を修正</li><li>ドライブを連続的に削除すると、サーバーヘルスが一時的にクリティカルを示すというまれな問題を修正</li><li>予期しないPCIConfiglinkページイベント、仮想SESデバイスへのタスク管理のタイムアウトメッセージがsnapdumpに記録される問題を修正</li><li>空のベイにスロット対応プロトコルがない問題を修正</li><li>コントローラーに接続されたLTOのリンク速度が[不明]と表示される問題を修正</li><li>Request Senseコマンドにより、サニタイズが進行中のドライブでタスク管理が実行される問題を修正。</li><li>255を超える値が使用された場合に、Redfish PATCH StorageController[ControllerRates]がランダムな値を暗黙的に設定してしまう問題を修正。</li><li>コントローラーがパススルーとして構成されているときにVMを再起動すると、誤ったコントローラーエラーイベントが記録される可能性がある問題を修正</li><li>2つのバックプレーンが同じストレージポートに接続されている場合、Redfishファブリックポートのアクティブ幅と現在の速度が間違っているという問題を修正。</li><li>再起動後にNVMeドライブのリンクステータスが失敗する可能性があるというまれな問題を修正 </li><li>複数のドライブの取り外しと挿入が短時間に行われたときにコントローラーがアサートされる可能性があるというまれな問題を修正</li><li>SATAパススルーコマンドが実行中の場合、SATAドライブのサニタイズのパーセンテージが進行しない問題を修正</li><li>NVMeドライブでサニタイズのパーセンテージが進行しない問題を修正</li><li>読み取り/書き込みコマンドと非読み取り/書き込みコマンドの耐久テストでIOタイムアウトとデバイスリセットが発生することがあるというまれな問題を修正</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"cn"}],"Version":"52.32.3-6333"},{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfish デバイス有効化の機能強化<ul><li>Redfishボリューム変換サポート<ul><li>POST #Volume.ChangeRAIDLayout: RAIDレイアウトの変更。RAIDレイアウトの変更は、入力JSONボディにターゲットRAIDTypeとドライブのリストを提供することで実現されます。</li><li>POST #Volume.ChangeRAIDLayout: サイズ変更。ChangeRAIDLayoutを使用すると、RAIDTypeを変更せずに新しい未構成正常ドライブを追加することでボリュームのサイズを変更できます。このような場合、入力JSONボディでRAIDTypeを指定してはいけませんが、それに応じて完全なドライブリストを指定する必要があります。</li><li>PATCH Volume[CapacityBytes]: この操作は、ボリューム内に利用可能な未使用サイズがある場合にボリュームのサイズを変更するために使用されます。ここに新しいドライブを追加するスコープはありません</li><li>POST #Volume.CheckConsistency: この操作は、ボリューム上の整合性チェック操作を開始します。この操作では入力は想定されません。</li></ul></li><li>Redfish Metrics GETサポート<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount、CorrectableECCErrorCount、CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount、SAS.LossOfDwordSynchronizationCount、SAS.RunningDisparityErrorCount、PCIeErrors.CorrectableErrorCount、PCIeErrors.FatalErrorCount、PCIeErrors.NonFatalErrorCount</li><li>各カウンターは最大65535までの値を保持できます。カウンターが最大値に達しても、値はリセットされません。</li><li>ユーザーがコントローラーのNVRAMクリアまたはRedfish ResetToDefaults.ResetAllを実行すると、メトリックはクリアされます。</li></ul></li></ul></li><li>MRSAおよびstorcli工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加。<ul><li>コントローラー上に構成が存在する場合、または固定キャッシュが存在する場合、NVRAMクリア操作は許可されません。</li><li>NVRAMをクリアした後、コントローラーFWはオンラインコントローラーリセット (OCR) を実行します。何らかの理由でOCRを実行できない場合は、システムを再起動するようにユーザーに通知されます。</li><li>NVRAMクリア操作は、機能的にはRedfish ResetToDefaults.ResetAll操作と同等です。</li></ul></li><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。非ホットプラグ構成の場合、コントローラーは常に16個のベイを表示します。</li></ul>","Fixes":"<ul><li>a00143124en_usアドバイザリを修正: HPE MR Gen11 コントローラー - HPE Gen11サーバー上のMR Gen11コントローラーがIMLで\"WriteCacheDataLoss\"を生成できない場合がある</li><li>a00148035en_usアドバイザリを修正: HPE MR Gen11コントローラー - ベイとボックスのNVMeドライブの場所がワンタイムブートメニューに表示されない</li><li>Linux OSでLTOの128KBを超える読み取り/書き込み転送が失敗する問題を修正</li><li>Backup ExecがLTOで動作しない問題を修正</li><li>240個の論理ドライブが構成されている場合、サーバーのブート時にコントローラーがiLOによってドロップされる可能性がある問題を修正</li><li>ドライブを連続的に削除すると、サーバーヘルスが一時的にクリティカルを示すというまれな問題を修正</li><li>予期しないPCIConfiglinkページイベント、仮想SESデバイスへのタスク管理のタイムアウトメッセージがsnapdumpに記録される問題を修正</li><li>空のベイにスロット対応プロトコルがない問題を修正</li><li>コントローラーに接続されたLTOのリンク速度が[不明]と表示される問題を修正</li><li>Request Senseコマンドにより、サニタイズが進行中のドライブでタスク管理が実行される問題を修正。</li><li>255を超える値が使用された場合に、Redfish PATCH StorageController[ControllerRates]がランダムな値を暗黙的に設定してしまう問題を修正。</li><li>コントローラーがパススルーとして構成されているときにVMを再起動すると、誤ったコントローラーエラーイベントが記録される可能性がある問題を修正</li><li>2つのバックプレーンが同じストレージポートに接続されている場合、Redfishファブリックポートのアクティブ幅と現在の速度が間違っているという問題を修正。</li><li>再起動後にNVMeドライブのリンクステータスが失敗する可能性があるというまれな問題を修正 </li><li>複数のドライブの取り外しと挿入が短時間に行われたときにコントローラーがアサートされる可能性があるというまれな問題を修正</li><li>SATAパススルーコマンドが実行中の場合、SATAドライブのサニタイズのパーセンテージが進行しない問題を修正</li><li>NVMeドライブでサニタイズのパーセンテージが進行しない問題を修正</li><li>読み取り/書き込みコマンドと非読み取り/書き込みコマンドの耐久テストでIOタイムアウトとデバイスリセットが発生することがあるというまれな問題を修正</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"cn"}],"Version":"52.32.3-6333"}],"SWKeys":[{"Name":"02931590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"98769e560a3445ecbeffcbf2cbf612a7"}]},{"ProductId":"8e8fd25144334177930f2db95d492320","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following SATA drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。VK000480GWTHA、VK000960GWTHB、VK001920GWTHC およびVK003840GWTHDドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4113520","DateModified":"2025-11-14T11:02:15","FileList":["cp068666.xml","cpqsetup.exe","K401HPG5.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"602edbf5411adbcf7209e3fe2169e6fd","Name":"cp068666.exe","Release":"2025-11-14T10:57:46","Revision":"D","SHA1Sum":"d5add7de0b103d6b9f09017eb55b228239259c5f","SHA256Sum":"c48cad8ebb9094ae595c5a4a9139daa1923e2413bc9e73f4bfeb25c2679e2368","Size":"3MB","TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -VK000480GWTHA、VK000960GWTHB、VK001920GWTHC、およびVK003840GWTHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK003840GWTHD","TargetGUID":"562340a5-304b-3330-3834-304757544844","Type":"sata"},{"Id":"VK001920GWTHC","TargetGUID":"562340a5-304b-3130-3932-304757544843","Type":"sata"},{"Id":"VK000960GWTHB","TargetGUID":"562340a5-304b-3030-3936-304757544842","Type":"sata"},{"Id":"VK000480GWTHA","TargetGUID":"562340a5-304b-3030-3438-304757544841","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-09T01:49:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4949af45d6614c159f064c1c94c08476"}]},{"ProductId":"d7a820130b1346d2a8d4377d479232cf","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18850575","DateModified":"2025-03-06T13:48:25","FileList":["/CP065958_BUILD_5.data","/CP065958.vmexe64","/CP065958.vmfile","/CP065958_VMw.zip","/CP065958.xml","/payload.json","/CP065958_VMw.zip/index.xml","/CP065958_VMw.zip/vendor-index.xml","/CP065958_VMw.zip/metadata.zip","/CP065958_VMw.zip/vib20/CP065958/HPE_bootbank_CP065958_HPD4.5-1OEM.800.1.0.20613240.vib","/CP065958_VMw.zip/metadata.zip/vendor-index.xml","/CP065958_VMw.zip/metadata.zip/vmware.xml","/CP065958_VMw.zip/metadata.zip/vibs/CP065958--6752308024534835670.xml","/CP065958_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065958_HPD4.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"ae49d96f6a339f27b9dccef6175a470c","Name":"CP065958.zip","Release":"2025-03-06T13:47:37","Revision":"B","SHA1Sum":"2ed99a1c49f426e19c12fecaa486770ef1f03c41","SHA256Sum":"f56b49310d895eaa06200e158a95115e7502cc764aba495d11cccd3389b77d87","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"2","Version":"HPD4","VibList":[{"Name":"CP065958","Version":"HPD4.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040692.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MO006400JWUGB","TargetGUID":"4d2340a5-304f-3630-3430-304a57554742","Type":"sas"},{"Id":"MO003200JWUGA","TargetGUID":"4d2340a5-304f-3330-3230-304a57554741","Type":"sas"},{"Id":"MO001600JWUFV","TargetGUID":"4d2340a5-304f-3130-3630-304a57554656","Type":"sas"},{"Id":"EO001600JWUGE","TargetGUID":"452340a5-304f-3130-3630-304a57554745","Type":"sas"},{"Id":"MO000800JWUFU","TargetGUID":"4d2340a5-304f-3030-3830-304a57554655","Type":"sas"},{"Id":"EO000800JWUGD","TargetGUID":"452340a5-304f-3030-3830-304a57554744","Type":"sas"},{"Id":"MO000400JWUFT","TargetGUID":"4d2340a5-304f-3030-3430-304a57554654","Type":"sas"},{"Id":"EO000400JWUGC","TargetGUID":"452340a5-304f-3030-3430-304a57554743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:44:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、HPE Customer Bulletin: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"de5f63eab149463783b82001b23764bb"}]},{"ProductId":"ad11e7e4956147cc81b160d5c8d519df","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This firmware release provides additional protection against command timeouts.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>This firmware release provides additional protection against command timeouts.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3629144","DateModified":"2025-08-02T22:10:20","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-1.1/CP067386.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-1.1/TAMG06scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067386.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067386.scexe"],"MD5Sum":"048eab2ebf54cec2886c14fca44fc761","Name":"firmware-hdd-faf39e0ff7_0HPD9-1.1_amd64.deb","Release":"2025-08-03T03:02:03","Revision":"","SHA1Sum":"f07647a6b47817be419e34218080133a025bcb8a","SHA256Sum":"1af635ab646bddc46a1f08273ef798f516af7a0d8f4a82d7bbd5e41c2af7eb0e","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000JWJRQ","TargetGUID":"4d2340a5-3042-3830-3030-304a574a5251","Type":"sas"},{"Id":"MB006000JWJRP","TargetGUID":"4d2340a5-3042-3630-3030-304a574a5250","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T21:25:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware release provides additional protection against command timeouts.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware release provides additional protection against command timeouts.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware release provides additional protection against command timeouts.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b84cdb6503604ad4ab61625e6b258c61"}]},{"ProductId":"8e4da865e5b44ea38e4b650ce9a93715","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4313440","DateModified":"2025-11-16T15:46:17","FileList":["cp068731.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNESD8.rel","setup.dll"],"MD5Sum":"a9e2f0156696abc3d8c4a29b692e1302","Name":"cp068731.exe","Release":"2025-11-16T15:40:51","Revision":"E","SHA1Sum":"b5d626da7d6e17b54a903a95414f2f985d831aed","SHA256Sum":"d407186cef9820b83cc17ef223acb56e90fb3d94f3d2870e24665d0b9a01354f","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB006000JWWQN","TargetGUID":"4d2340a5-3042-3630-3030-304a5757514e","Type":"sas"},{"Id":"MB008000JWWQP","TargetGUID":"4d2340a5-3042-3830-3030-304a57575150","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T04:51:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8aa7071f46d84a058e94d592872206e0"}]},{"ProductId":"7a0e2103ab3d449ea173c873ce94c871","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"Lang":"cn","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility CLIは、サポートされているドライブのSmartSSD Wear Gauge情報の提供を含む、SmartアレイおよびSmartRAIDコントローラーとサポートされているデバイスのためのコマンドラインベースのディスク構成プログラムです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"3672141","DateModified":"2025-12-05T02:17:28","FileList":["./opt/smartstorageadmin/ssaducli","./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/man/man8/ssaducli.8.gz","./usr/sbin/ssaducli","./usr/share/smartupdate/ssaducli/component.xml"],"MD5Sum":"c539766277f766ec6ae6161183644278","Name":"ssaducli-6.60-8.0.x86_64.rpm","Release":"2025-12-05T02:15:06","Revision":"","SHA1Sum":"7bbd330638514a5b38df451f48f2af59848f31fc","SHA256Sum":"9c92d2d2336906604742180757513a50a7fef9127c8241f1c753477d8542eed7","Size":"3MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"TypeOfChange":"1","Version":"6.60.8.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>SSADUCLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSADUCLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li></ul>"},{"Lang":"ja","Value":"<ul><li>SSADUCLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSADUCLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li></ul>"},{"Lang":"cn","Value":"<ul><li>SSADUCLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSADUCLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:17:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"cn"}],"Version":"6.50.11.0"},{"ReleaseNotes":[{"Enhancements":"<p>RC drop 6.60.8.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RC drop 6.60.8.0.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>RC drop 6.60.8.0.</p>","Fixes":"","Lang":"cn"}],"Version":"6.60.8.0"}],"SWKeys":[{"Name":"ssaducli","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b655bf12f1ec45248db5262428b859da"}]},{"ProductId":"3b6a8a58b8154bb1b3a7b5b4416448b8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB016000JWXKH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4013456","DateModified":"2025-11-15T09:07:21","FileList":["cp068758.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG08scHPDC.rel"],"MD5Sum":"ebd9795e127a7ffdba67ad2b810c46b3","Name":"cp068758.exe","Release":"2025-11-15T09:02:06","Revision":"C","SHA1Sum":"07290ec52eb31aad45ff534799d97d338017761d","SHA256Sum":"51db9e68ced18af9c6daf2b521a63ec310c8034043ba14a94e7173b85207fb58","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JWXKH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB016000JWXKHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB016000JWXKH","TargetGUID":"4d2340a5-3042-3631-3030-304a57584b48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T09:17:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。</li><li>このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPDC"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。</li><li>このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPDC"}],"SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"82fb0e5310174d9195ce89abea9bf90c"}]},{"ProductId":"5f659aa091e040538f3e83b28f048f1f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu&nbsp;Linux (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu&nbsp;Linux (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Ubuntu&nbsp;Linux (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"6885924","DateModified":"2025-08-03T00:59:37","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-1.1/CP067328.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-1.1/MPK7825Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067328.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067328.scexe"],"MD5Sum":"9407855ab16e0cedd0dacbbf80103bba","Name":"firmware-hdd-951aefd63e_0MPK7825Q-1.1_amd64.deb","Release":"2025-08-03T05:52:18","Revision":"","SHA1Sum":"f0ba6fbff9b7191d698a3c7e4718d4403c7c8f32","SHA256Sum":"42c3ff17be36604dc6c405e0ed7bff1989f96008c6fd51a7cf647f655618a5a2","Size":"6MB","TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3 and MZXLR7T6HALA-000H3  Drive"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3 and MZXLR7T6HALA-000H3  Drive"},{"Lang":"ja","Value":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3 and MZXLR7T6HALA-000H3  Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXLR12THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3132-544869b8df72","Type":"nvme"},{"Id":"MZXLR15THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3135-5448e88a517e","Type":"nvme"},{"Id":"MZXLR7T6HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3754-36484bc80db1","Type":"nvme"},{"Id":"MZXLR1T6HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Type":"nvme"},{"Id":"MZXLR800HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3830-3048c3876295","Type":"nvme"},{"Id":"MZXLR3T2HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3248a4bea716","Type":"nvme"},{"Id":"MZXLR6T4HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Type":"nvme"},{"Id":"MZXLR1T9HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3948cda93afa","Type":"nvme"},{"Id":"MZXLR3T8HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3848df400867","Type":"nvme"},{"Id":"MZXLR960HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3936-3048d2d64915","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T11:48:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK7825Q"}],"SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c4ea7038d4c347e69fb94a7078bba200"}]},{"ProductId":"5ccf2d3c6d81402baa3db964a93e8c96","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"4538324","DateModified":"2025-08-03T01:44:44","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-1.1/CP067345.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-1.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067345.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067345.scexe"],"MD5Sum":"870dc0b3759f91583774af525f70c150","Name":"firmware-hdd-6b7ce3da0e_0HPG2-1.1_amd64.deb","Release":"2025-08-03T06:38:05","Revision":"","SHA1Sum":"82aa8ab5269561a9442c4af18fd51c73f545663c","SHA256Sum":"ea67374331198d2180f91be8bfbf4cf7dfffd23b1bf48d0809be7271e778edac","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"Installation":{"Command":"CP041455.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000GWRTN","TargetGUID":"4d2340a5-3042-3431-3030-30475752544e","Type":"sata"},{"Id":"MB012000GWRTL","TargetGUID":"4d2340a5-3042-3231-3030-30475752544c","Type":"sata"},{"Id":"MB010000GWRTK","TargetGUID":"4d2340a5-3042-3031-3030-30475752544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:33:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware contains a fix for a data integrity issue that could occur during a power cycle while the drive is processing write commands.</li></ul>","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9482473f716747c0b19615fdd20186d0"}]},{"ProductId":"07a5f3ddb9bd4168818fb38406e49473","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5522957","DateModified":"2025-09-17T13:09:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/CP068854.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/WBCPssssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068854.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068854.scexe"],"MD5Sum":"5983072606ff5e4b6fe2cc0879ee9a3b","Name":"firmware-hdd-ef93133161-HPD4-4.1.x86_64.rpm","Release":"2025-09-17T17:59:06","Revision":"D","SHA1Sum":"f47c954b8b2fb2d1182df2756cfd01fd6d737749","SHA256Sum":"f8867e559a63ee939b9634c764c4402fd9a63827694c92e48b90965f9707279f","Size":"5MB","TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040353.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MO006400JWUGB","TargetGUID":"4d2340a5-304f-3630-3430-304a57554742","Type":"sas"},{"Id":"MO003200JWUGA","TargetGUID":"4d2340a5-304f-3330-3230-304a57554741","Type":"sas"},{"Id":"MO001600JWUFV","TargetGUID":"4d2340a5-304f-3130-3630-304a57554656","Type":"sas"},{"Id":"EO001600JWUGE","TargetGUID":"452340a5-304f-3130-3630-304a57554745","Type":"sas"},{"Id":"MO000800JWUFU","TargetGUID":"4d2340a5-304f-3030-3830-304a57554655","Type":"sas"},{"Id":"EO000800JWUGD","TargetGUID":"452340a5-304f-3030-3830-304a57554744","Type":"sas"},{"Id":"MO000400JWUFT","TargetGUID":"4d2340a5-304f-3030-3430-304a57554654","Type":"sas"},{"Id":"EO000400JWUGC","TargetGUID":"452340a5-304f-3030-3430-304a57554743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:39:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"728eef229104453693c5a71e677c1770"}]},{"ProductId":"d36b5614c00b4d00b66a58209cc5bffb","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U41_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11654215","DateModified":"2026-01-12T00:46:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.62_2026_01_09-1.1/CP070267.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.62_2026_01_09-1.1/U41_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070267.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070267.scexe"],"MD5Sum":"acea809026514eaebb017f65c12742d7","Name":"firmware-system-u41-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-12T06:33:59","Revision":"","SHA1Sum":"d9a0ba32c56f80092aa8401baeb93f8e38338301","SHA256Sum":"1f1ae6fa31e9e4aa66d03a8c75d778664bb672668a04e4dee8d53b1677abe759","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen10 (U41) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML350 Gen10 (U41) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen10 (U41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T06:33:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"dd67d87fae5b4df1b390bdae09f940b8"}]},{"ProductId":"575b91de95af482eb3a08ed94402e2c3","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUASG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3432-3030-30475945564b","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB24000GYEVK"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MB24000GYEVK"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB24000GYEVK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; FW assert fix and other regular maintenance release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; FW assert fix and other regular maintenance release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; FW assert fix and other regular maintenance release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3294480","DateModified":"2024-10-25T07:57:21","FileList":["payload.json","Seagate_Summit_SUMMITSUASG1.HPb","Seagate_Summit_SUMMITSUASG1.xml"],"MD5Sum":"781c1a56c20ac0769586fded47d59180","Name":"Seagate_Summit_SUMMITSUASG1.fwpkg","Release":"2024-10-25T07:55:19","Revision":"","SHA1Sum":"75b1ded20aa896a35f0dbd57b2847c586030963e","SHA256Sum":"13d8c5df5e9044081ad690380aa1de044c4a4e0d627b3ee3174321c58f1fdff5","Size":"3MB","TargetGUIDs":["002340a5-424d-3432-3030-30475945564b"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB24000GYEVK"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MB24000GYEVK"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB24000GYEVK"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB24000GYEVK","TargetGUID":"002340a5-424d-3432-3030-30475945564b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-25T06:15:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>FW assert fix and other regular maintenance release.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>FW assert fix and other regular maintenance release.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>FW assert fix and other regular maintenance release.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB24000GYEVK","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"675c69d416134f789231a11d446f13a9"}]},{"ProductId":"3126d8d47de5417a878b30ed83f0673f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This driver, MegaSAS35, provides Windows 2022 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers"},{"Lang":"ja","Value":"このドライバー、MegaSAS35は、HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a Gen10p コントローラーおよびMR416i-o、MR416i-p、MR216i-o、MR216i-p、MR408i-o、MR408i-p Gen11コントローラー用のWindows 2022 64ビットのサポートを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"920792","DateModified":"2025-12-02T06:57:21","FileList":["cp069945.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"MD5Sum":"1f528784339ba910e751f2b0702af55a","Name":"cp069945.exe","Release":"2025-12-02T06:54:52","Revision":"C","SHA1Sum":"2b294f758ed29997c086f3cde68af8cb522cd47d","SHA256Sum":"7ef6ac4992d598ab32d9918fc4af96b1963ff7e6d454025fa380c22f0bf6f559","Size":"899KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.732.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>"},{"Lang":"ja","Value":"<p>ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2022 edition"},{"Lang":"ja","Value":"MR416i-p、MR416i-a、MR216i-p、MR216i-a Gen10pコントローラーおよびMR416i-o、MR416i-p、MR216i-o、MR216i-p、MR408i-o 、MR408i-p Gen11コントローラードライバーfor Microsoft Windows 2022 edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1440"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-01T03:06:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that system may crash when importing Logical Drive.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>論理ドライブをインポートするときにシステムがクラッシュする可能性がある問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that system may crash when importing Logical Drive.</li></ul>","Lang":"cn"}],"Version":"7.732.3.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated component metadata.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated component metadata.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated component metadata.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.732.3.0"}],"SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"60a0f741fa9940ef963118e35e24db79"}]},{"ProductId":"376766abc4f1493fa567046abeb8b7d6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5548208","DateModified":"2025-11-11T09:00:29","FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-qla2xxx","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"MD5Sum":"9febe004a57d8f562ca50bd29742cf46","Name":"kmod-qlgc-qla2xxx-10.02.15.00_k1-1.rhel10u1.x86_64.rpm","Release":"2025-11-11T08:55:04","Revision":"","SHA1Sum":"10984a664cb22ac427a4b5a326d069087596e276","SHA256Sum":"cf07ed1009447f8201864b17d38fe13836cb134f897b2ef3fa6d7a6a2bf8d0b3","Size":"5MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.15.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel10u1.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel10u1.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.15.00.a8_k1-1.rhel10u1.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 10 Update 1 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 10 Update 1 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 10 Update 1 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-12T07:02:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.15.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.15.00-k1"}],"SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a8164eb9fed14378adc4f977ed8363b9"}]},{"ProductId":"5f4b3c5f1985447a820cdfec1e7b0bb1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1039936","DateModified":"2025-11-16T04:05:21","FileList":["cp069552.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs.cat","ixs.inf","ixs.sys","ixsmsg.dll","nicdrvr.dll"],"MD5Sum":"86f3c381a07d99bb9e17f0af0d0c130d","Name":"cp069552.exe","Release":"2025-11-16T03:50:42","Revision":"B","SHA1Sum":"fafbd4ffb6ca9a8fa45b272464ff14deccae10ed","SHA256Sum":"6cadac092a76e7c6682cab3433a98577aa493690f2208143d93eb1884be7b837","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"TypeOfChange":"1","Version":"4.2.7.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixs Driver for Windows Server 2025"},{"Lang":"ja","Value":"Windows Server 2025用HPE Intel ixsドライバー"},{"Lang":"cn","Value":"HPE Intel ixs Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This prodcut has a minor change on updating the package scripts.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品では、パッケージスクリプトのアップデートに関してマイナーな変更が加えられています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This prodcut has a minor change on updating the package scripts.</p>","Fixes":"","Lang":"cn"}],"Version":"4.2.7.0"},{"ReleaseNotes":[{"Enhancements":"<p>This prodcut has a minor change on updating the package scripts.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品では、パッケージスクリプトのアップデートに関してマイナーな変更が加えられています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This prodcut has a minor change on updating the package scripts.</p>","Fixes":"","Lang":"cn"}],"Version":"4.2.7.0"}],"SWKeys":[{"Name":"ixs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\ixs.inf_amd64_166a1f78fe537c55"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3116ddb609f54ed5ab42139bfadf6447"}]},{"ProductId":"260b73b77b824e60a7231a400ce24c25","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"3908952","DateModified":"2025-11-16T16:10:20","FileList":["cp068665.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNNTG6.rel","setup.dll"],"MD5Sum":"5ccd17c64752e47c02e991ae8d285279","Name":"cp068665.exe","Release":"2025-11-16T16:05:24","Revision":"D","SHA1Sum":"d3be0c01e65dc927094aa1636f10a305bf2955c3","SHA256Sum":"a1f701b315e51a52dc98ac6a12896b580329ed4fc5d6e430b5533ccc9d12e63a","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000GWWQH","TargetGUID":"4d2340a5-3042-3430-3030-304757575148","Type":"sata"},{"Id":"MB002000GWWQF","TargetGUID":"4d2340a5-3042-3230-3030-304757575146","Type":"sata"},{"Id":"MB001000GWWQE","TargetGUID":"4d2340a5-3042-3130-3030-304757575145","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T10:02:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"dd4d0089d26745a78f0c891836635576"}]},{"ProductId":"ba1b35ce71154e9e8335778f038c2885","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JXUCC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JXUCC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"7193156","DateModified":"2025-09-17T12:01:11","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/CP068851.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/PCHFA2BP.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068851.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068851.scexe"],"MD5Sum":"cefaaafe228b9504a9e3bd441857ddfc","Name":"firmware-hdd-017797f12e-HPD4-6.1.x86_64.rpm","Release":"2025-09-17T16:52:05","Revision":"F","SHA1Sum":"5ceb4708a2a187507028a2a169407275529e130d","SHA256Sum":"fd181315d21147383bfa18d51645c0c546d24103952e849c627a118bd73d0222","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JXUCC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JXUCCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JXUCC","TargetGUID":"4d2340a5-3042-3431-3030-304a58554343","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T19:19:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"118afb87880649a9ac415ea8d33bf1df"}]},{"ProductId":"eaf211f134ef40ba8eea9bd4163e6e57","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-igb-5.14.16-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-igb) to (igb). Now we revert this change from (igb) to (<strong>hp</strong>-igb).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-igb and kmod-igb are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-igb-5.14.16-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-igb and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>  このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-igb-5.14.16-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-igb）から（igb）に変更されました。この変更を（igb）から（<strong>hp</strong>-igb）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-igbとkmod-igbはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-igb-5.14.16-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-igbによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-igb-5.14.16-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-igb) to (igb). Now we revert this change from (igb) to (<strong>hp</strong>-igb).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-igb and kmod-igb are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-igb-5.14.16-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-igb and then install the updated RPM.</p>"}],"Files":[{"Bytes":"182960","DateModified":"2025-09-16T08:21:36","FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-igb","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/918fed244b12f9a0e75569b087ed727228ba49","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"MD5Sum":"bff8126ed9da4503041b2c8fce033e47","Name":"kmod-hp-igb-5.19.4-1.rhel9u5.x86_64.rpm","Release":"2025-09-16T08:13:52","Revision":"","SHA1Sum":"966ab7712fad57c60e562b3aa12c0c99a198174a","SHA256Sum":"a0fa25f95bf798f37b6fe1f3b7556b05b53eed5b1729a6616fdef1c9da17d169","Size":"178KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"TypeOfChange":"1","Version":"5.19.4-1"},{"Bytes":"183093","DateModified":"2025-09-16T08:25:01","FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-igb","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/0b","./usr/lib/.build-id/0b/524ed9ec5ccac51888381e15f17cabb3d0c73f","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"MD5Sum":"9e9fadadb3912dd64ec2da9dc691cf1d","Name":"kmod-hp-igb-5.19.4-1.rhel9u6.x86_64.rpm","Release":"2025-09-16T08:13:52","Revision":"","SHA1Sum":"acf85ec29a01760eba12a19bddab3716a9688af6","SHA256Sum":"c14360bbf79eca2fd424f061a141b2084cc7626143b787b598f1e39214add490","Size":"178KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"TypeOfChange":"1","Version":"5.19.4-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel igb Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel igbドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel igb Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T04:30:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.6.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在Red Hat Enterprise Linux 9.6をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.6.</p>","Fixes":"","Lang":"cn"}],"Version":"5.19.3-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"5.19.4-1"}],"SWKeys":[{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"9b0df02d8403461ea2b98e2ea4df0d64"}]},{"ProductId":"f0e80dda550e422981f666fd854cb6f6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3663448","DateModified":"2025-11-15T15:43:22","FileList":["cp068752.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WBCQssssASFD2.rel"],"MD5Sum":"69e3fe515f3069e370c7aceee69b90ee","Name":"cp068752.exe","Release":"2025-11-15T15:37:53","Revision":"C","SHA1Sum":"1f73738859667975bc361cfdb46e0aac4153153a","SHA256Sum":"f0fce030a655ee17f8d2365ad447e6394b0e746a1738d39e3afba5577d3dc2c3","Size":"3MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MO000800JXBEV","TargetGUID":"4d2340a5-304f-3030-3830-304a58424556","Type":"sas"},{"Id":"MO001600JXBFP","TargetGUID":"4d2340a5-304f-3130-3630-304a58424650","Type":"sas"},{"Id":"MO003200JXBFQ","TargetGUID":"4d2340a5-304f-3330-3230-304a58424651","Type":"sas"},{"Id":"MO006400JXBFR","TargetGUID":"4d2340a5-304f-3630-3430-304a58424652","Type":"sas"},{"Id":"MO000960JXBFA","TargetGUID":"4d2340a5-304f-3030-3936-304a58424641","Type":"sas"},{"Id":"MO001920JXBFT","TargetGUID":"4d2340a5-304f-3130-3932-304a58424654","Type":"sas"},{"Id":"MO003840JXBFU","TargetGUID":"4d2340a5-304f-3330-3834-304a58424655","Type":"sas"},{"Id":"EO000400JXBEU","TargetGUID":"452340a5-304f-3030-3430-304a58424555","Type":"sas"},{"Id":"EO000800JXBFL","TargetGUID":"452340a5-304f-3030-3830-304a5842464c","Type":"sas"},{"Id":"EO001600JXBFN","TargetGUID":"452340a5-304f-3130-3630-304a5842464e","Type":"sas"},{"Id":"MO015360JXBFV","TargetGUID":"4d2340a5-304f-3531-3336-304a58424656","Type":"sas"},{"Id":"MO007680JXBGA","TargetGUID":"4d2340a5-304f-3730-3638-304a58424741","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:48:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"658a48b6cc0742208d5882f3f0d95021"}]},{"ProductId":"2f9cefc3934e4e93835fb42cb71a4161","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility CLIは、サポートされているドライブのSmartSSD Wear Gauge情報の提供を含む、SmartアレイおよびSmartRAIDコントローラーとサポートされているデバイスのためのコマンドラインベースのディスク構成プログラムです。"},{"Lang":"cn","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"2891060","DateModified":"2026-01-28T14:19:48","FileList":["./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/sbin/ssaducli","./usr/share/doc/ssaducli/changelog.Debian.gz","./usr/share/doc/ssaducli/copyright","./usr/share/man/man8/ssaducli.8.gz","./usr/share/smartupdate/ssaducli/component.xml"],"MD5Sum":"6848360d1464c87624a2ed7f6e5742a6","Name":"ssaducli-6.60-8.0_amd64.deb","Release":"2026-01-28T14:19:26","Revision":"","SHA1Sum":"050385a68e2367e2cec1e85502da8d747af03a03","SHA256Sum":"78c1e059eb4232376130a9a1bbe4494d09a0dcae18d7839f8e55506b476e43ce","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"TypeOfChange":"1","Version":"6.60.8.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>If there is an older version of SSADUCLI installed on the system, please use &quot;dpkg -r &lt;package-name&gt;&quot; &nbsp;to remove configuration files and&nbsp;dpkg --purge &lt;package-name&gt;&nbsp; to&nbsp;remove completely.</li><li>Use &quot;sudo dpkg -i&nbsp;&nbsp; &lt;package-name&gt;&nbsp;&quot;&nbsp; &nbsp;to install the application.</li><li>The software resides in &nbsp;/opt/smartstorageadmin/ssaducli and the executable name is ssaducli which is located in /usr/sbin.</li></ul><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>システムにSSADUCLIの古いバージョンがインストールされている場合は、「dpkg -r <パッケージ名>設定ファイルを削除し、dpkg --purge <パッケージ名> 完全に削除します。</li><li>アプリケーションをインストールするために、「sudo dpkg -i <package-name>」を使用します。</li><li>このソフトウェアは/opt/smartstorageadmin/ssaducliにあり、実行可能ファイル名は/usr/sbinに配置されているssaducliです。</li></ul><p> </p><p> </p>"},{"Lang":"cn","Value":"<ul><li>If there is an older version of SSADUCLI installed on the system, please use &quot;dpkg -r &lt;package-name&gt;&quot; &nbsp;to remove configuration files and&nbsp;dpkg --purge &lt;package-name&gt;&nbsp; to&nbsp;remove completely.</li><li>Use &quot;sudo dpkg -i&nbsp;&nbsp; &lt;package-name&gt;&nbsp;&quot;&nbsp; &nbsp;to install the application.</li><li>The software resides in &nbsp;/opt/smartstorageadmin/ssaducli and the executable name is ssaducli which is located in /usr/sbin.</li></ul><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11コントローラー"},{"Lang":"cn","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:17:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"cn"}],"Version":"6.50.11.0"},{"ReleaseNotes":[{"Enhancements":"<ul style=\"list-style-type:disc\"><li>Modified the SSACLI component version format to meet the new requirement from VMware ESXi for 9.1</li><li>Added spare type decoding in Array Diagnostic Utility (ADU) reports to indicate whether a logical drive uses dedicated or auto-replace spares</li><li>Modified the default strip size for NVMe drives based on the Maximum Data Transfer Size (MDTS), and tools will set the default strip size to the minimum supported MDTS value when creating or migrating a logical drive</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul style=\"list-style-type:disc\"><li>Modified the SSACLI component version format to meet the new requirement from VMware ESXi for 9.1</li><li>Added spare type decoding in Array Diagnostic Utility (ADU) reports to indicate whether a logical drive uses dedicated or auto-replace spares</li><li>Modified the default strip size for NVMe drives based on the Maximum Data Transfer Size (MDTS), and tools will set the default strip size to the minimum supported MDTS value when creating or migrating a logical drive</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul style=\"list-style-type:disc\"><li>Modified the SSACLI component version format to meet the new requirement from VMware ESXi for 9.1</li><li>Added spare type decoding in Array Diagnostic Utility (ADU) reports to indicate whether a logical drive uses dedicated or auto-replace spares</li><li>Modified the default strip size for NVMe drives based on the Maximum Data Transfer Size (MDTS), and tools will set the default strip size to the minimum supported MDTS value when creating or migrating a logical drive</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.60.8.0"}],"SWKeys":[{"Name":"ssaducli","SWKeyExpectedPath":"software:deb"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"51e6c4ff673845d89df996472460dfb1"}]},{"ProductId":"d1880357890d41959529b109e2a869e4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB016000JXLBAおよびMB018000JXLAU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5336600","DateModified":"2025-11-15T17:33:13","FileList":["cp068749.xml","cpqsetup.exe","mnv_cli.exe","payload.json","PCHFA2B3.rel","setup.dll"],"MD5Sum":"2a6585e8431a2cba5cb80112997e57bc","Name":"cp068749.exe","Release":"2025-11-15T17:27:54","Revision":"D","SHA1Sum":"fe5b3d34a007324d9151244e199202819467028f","SHA256Sum":"926d7a57e8af5a53ff1a3bcba9c2bcecf4bb1b57f787f77e715bb9d5de7a15cf","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JXLBA and MB018000JXLAU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB016000JXLBAおよび MB018000JXLAUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB016000JXLBA","TargetGUID":"4d2340a5-3042-3631-3030-304a584c4241","Type":"sas"},{"Id":"MB018000JXLAU","TargetGUID":"4d2340a5-3042-3831-3030-304a584c4155","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:26:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c31b9cb8342244b7aab937df42e467f7"}]},{"ProductId":"24ef5d7f7f9443c598148daa0f16246b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1415504","DateModified":"2025-11-16T12:20:14","FileList":["cp069532.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"MD5Sum":"a59b809bb9997e7f2bfb394f2a67b3c2","Name":"cp069532.exe","Release":"2025-11-16T12:06:12","Revision":"B","SHA1Sum":"7c0733e45be13bab727af4ef64635d0a9e2e917e","SHA256Sum":"1ded7b49f58b8bee7a03bc80e482a7875c7bfb1aab003cc63baf67fda99f0a41","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.17.63.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel iavf Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Intel iavfドライバー for Windows Server 2025"},{"Lang":"cn","Value":"HPE Intel iavf Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CD","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37CD15900000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-154c103c0000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:50:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、VFドライバーが無効になっているかインストールされていない場合にVMトラフィックが機能しない可能性がある問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、VFドライバーが無効になっているかインストールされていない場合にVMトラフィックが機能しない可能性がある問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the VM traffic may not working when VF driver disabled or not installed.</p>","Lang":"cn"}],"Version":"1.17.63.0"}],"SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"dedc3c1f25d548b096eafb4386f0f946"}]},{"ProductId":"7dd14e7585784238bb6caec32dcf1d80","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This driver, MegaSAS35, provides Windows 2019 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10 Controller and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 controllers"},{"Lang":"ja","Value":"このドライバー、MegaSAS35は、HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a Gen10コントローラーおよびMR416i-o、MR416i-p、MR216i-o、MR216i-p、MR408i-o、MR408i-p Gen11コントローラー用のWindows Server 2019 64ビットのサポートを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"888632","DateModified":"2025-11-14T14:30:17","FileList":["cp069585.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"MD5Sum":"0d473914a2466639abe670fd1a307d78","Name":"cp069585.exe","Release":"2025-11-14T14:27:23","Revision":"B","SHA1Sum":"45016bfe2fb59461b84aee0821288b120871583f","SHA256Sum":"362a82f7b1b8efbbe0d43dd936b27a0d56a7cc9b4dea71cad9b2c7c5bf8a59e6","Size":"867KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.732.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>"},{"Lang":"ja","Value":"<p>ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers Driver for Microsoft Windows 2019 edition"},{"Lang":"ja","Value":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10pコントローラーおよびMR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11コントローラードライバーfor Microsoft Windows 2019 edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1440"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-14T02:36:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that system may crash when importing Logical Drive.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>論理ドライブをインポートするときにシステムがクラッシュする可能性がある問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that system may crash when importing Logical Drive.</li></ul>","Lang":"cn"}],"Version":"7.732.3.0"},{"ReleaseNotes":[{"Enhancements":"<p>Fix build tool certification issue.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Fix build tool certification issue.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Fix build tool certification issue.</p>","Fixes":"","Lang":"cn"}],"Version":"7.732.3.0"}],"SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"49fe9081c9ee40c6ad89c24ecc0b358b"}]},{"ProductId":"b0d91a06dd9c4473a208b93b1c088e41","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3&nbsp; Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3&nbsp; Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4430152","DateModified":"2025-11-15T19:58:13","FileList":["cp068645.xml","cpqsetup.exe","KACD6ALSGPK8.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"e4509ec34245d75296ad95223ea5c05c","Name":"cp068645.exe","Release":"2025-11-15T19:51:55","Revision":"B","SHA1Sum":"9a3a29fd48c789bb108eeabe590b28c5db3d2691","SHA256Sum":"80b2098234f5ffbb9dbd3d2899b59fcbca686a97a037ad4d22cd3cccbca9b87d","Size":"4MB","TargetGUIDs":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"KCD6XLUL7T68","TargetGUID":"002340a5-434b-3644-584c-554c37543638","Type":"nvme"},{"Id":"KCD6XVUL6T40","TargetGUID":"002340a5-434b-3644-5856-554c36543430","Type":"nvme"},{"Id":"KCD6XVUL1T60","TargetGUID":"002340a5-434b-3644-5856-554c31543630","Type":"nvme"},{"Id":"KCD6XVUL800G","TargetGUID":"002340a5-434b-3644-5856-554c38303047","Type":"nvme"},{"Id":"KCD6XVUL3T20","TargetGUID":"002340a5-434b-3644-5856-554c33543230","Type":"nvme"},{"Id":"KCD6XVUL12T8","TargetGUID":"002340a5-434b-3644-5856-554c31325438","Type":"nvme"},{"Id":"KCD6XLUL960G","TargetGUID":"002340a5-434b-3644-584c-554c39363047","Type":"nvme"},{"Id":"KCD6XLUL1T92","TargetGUID":"002340a5-434b-3644-584c-554c31543932","Type":"nvme"},{"Id":"KCD6XLUL3T84","TargetGUID":"002340a5-434b-3644-584c-554c33543834","Type":"nvme"},{"Id":"KCD6XLUL15T3","TargetGUID":"002340a5-434b-3644-584c-554c31355433","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:14:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>リセットの問題と定期的なメンテナンスファームウェアアップデートを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"GPK8"}],"SWKeys":[{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"11806acbfb014d739d8e94a6b58e1ef5"}]},{"ProductId":"809cff8704ac44759685c033bb7b76d3","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20249536","DateModified":"2025-03-06T09:39:33","FileList":["/CP065999_BUILD_5.data","/CP065999.vmexe64","/CP065999.vmfile","/CP065999_VMw.zip","/CP065999.xml","/payload.json","/CP065999_VMw.zip/index.xml","/CP065999_VMw.zip/vendor-index.xml","/CP065999_VMw.zip/metadata.zip","/CP065999_VMw.zip/vib20/CP065999/HPE_bootbank_CP065999_HPD2.5-1OEM.800.1.0.20613240.vib","/CP065999_VMw.zip/metadata.zip/vendor-index.xml","/CP065999_VMw.zip/metadata.zip/vmware.xml","/CP065999_VMw.zip/metadata.zip/vibs/CP065999--3281436684859785458.xml","/CP065999_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065999_HPD2.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"2180b2c156cc949677ae71714e03f47b","Name":"CP065999.zip","Release":"2025-03-06T09:38:42","Revision":"J","SHA1Sum":"f6a3ab65d0ce979f467b5573f3bcb81f56567087","SHA256Sum":"3e48199525870591afd12472395d71804a90d5aa4d756cdb9a0980e5973792ca","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP065999","Version":"HPD2.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP065999.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi -MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for ESXi - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000JWRTH","TargetGUID":"4d2340a5-3042-3431-3030-304a57525448","Type":"sas"},{"Id":"MB012000JWRTF","TargetGUID":"4d2340a5-3042-3231-3030-304a57525446","Type":"sas"},{"Id":"MB010000JWRTE","TargetGUID":"4d2340a5-3042-3031-3030-304a57525445","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:49:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fb0ba8f67f8f42d3ba9f214d072fe390"}]},{"ProductId":"effc199f67764de3b570f964be1aa0ce","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"DirectoryScan":false,"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component updates the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "},{"Lang":"ja","Value":"このコンポーネントは、HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバーをアップデートします "},{"Lang":"cn","Value":"This component updates the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"6919272","DateModified":"2025-11-14T03:17:20","FileList":["cp051154.compsig","cp051154.zip","cp051155.compsig","cp051155.zip","cp069587.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"b4e209f3dc364cc3af5b07c595bc32ea","Name":"cp069587.exe","Release":"2025-11-14T03:15:21","Revision":"E","SHA1Sum":"b3167040d37f08dfe6fa35195212d97d19aac8c3","SHA256Sum":"fe8fec7dec1c06db9214fdeededda003ca8427648ea2258bf6bacfa6b8b5d154","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。<br /> </p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers"},{"Lang":"ja","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers"},{"Lang":"cn","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T02:40:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p><p>Ver 0.2.3.0(B)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver 0.2.3.0と同等です。ファームウェアをバージョン0.2.3.0にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョン(B)にアップグレードする必要はありません。</p><p><strong>ファームウェアの依存関係:</strong></p><p> なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。一部のシステムでは、これによりCPU使用率が一時的に低下したり、ネットワークトラフィックの持続が1秒未満になったりする可能性があります。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(E) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision E if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(E) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision E if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(E) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision E if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"}],"SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:sd:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"08a87fb5ad0840a6b85d1093a80d9fd5"}]},{"ProductId":"957b79699cf847b3bc804b96d1108938","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor and chipset."},{"Lang":"ja","Value":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"636760","DateModified":"2025-11-17T06:03:16","FileList":["cp069694.xml","cpqsetup.exe","installer.dll","pnp/","pnp/IceLakeX.cat","pnp/IceLakeXSystem.inf","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Server_Common.cat","pnp/Server_CommonSystem.inf","pnp/Server_CommonSystemNorthpeak.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"MD5Sum":"1c103270a05d47051cdc1c6f68a53183","Name":"cp069694.exe","Release":"2025-11-17T06:00:26","Revision":"E","SHA1Sum":"8e1d31dfc151abd14e93372aeb3d6c9f02cf1b28","SHA256Sum":"d472b3c40af570e4c72154f029da330434ee82bccff37937b79199abcfa4e3dc","Size":"621KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19879.8585"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":3600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for Intel Xeon Scalable Processors (Third Generation) for Microsoft Windows"},{"Lang":"ja","Value":"Microsoft Windows用インテルXeonスケーラブルプロセッサー（第3世代）識別子"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-17T05:58:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19879.8585"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19879.8585"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1cc8cbad04d4490aa3fb86d133642ffa"}]},{"ProductId":"8ebc8805a4344ec4a24a5c7109c6e07f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"7663688","DateModified":"2025-11-17T03:17:17","FileList":["cp068637.xml","cpqsetup.exe","K503HPG3.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"a8c62052f6a41c265210472fe753a1b2","Name":"cp068637.exe","Release":"2025-11-17T03:12:04","Revision":"D","SHA1Sum":"4cdf59dcb6a950cd956af4e0e8ffff8bd953a0c4","SHA256Sum":"a8e84d46bac7e538737a7d41fb77cc8eb427ad8f35ffcecfeee63d6fbe5cc5db","Size":"7MB","TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MK003840GWXFL","TargetGUID":"4d2340a5-304b-3330-3834-30475758464c","Type":"sata"},{"Id":"MK001920GWXFK","TargetGUID":"4d2340a5-304b-3130-3932-30475758464b","Type":"sata"},{"Id":"MK000960GWXFH","TargetGUID":"4d2340a5-304b-3030-3936-304757584648","Type":"sata"},{"Id":"MK000480GWXFF","TargetGUID":"4d2340a5-304b-3030-3438-304757584646","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T08:53:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3b227ec4622c46b1a335f928e066d97d"}]},{"ProductId":"1368ab3d45fb40b799c33ccbe297c322","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U30_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11953646","DateModified":"2026-01-14T00:50:27","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.62_2026_01_09-1.1/CP070210.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.62_2026_01_09-1.1/U30_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070210.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070210.scexe"],"MD5Sum":"b2e87ecf1d26104fe276d87475bea384","Name":"firmware-system-u30-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-14T06:41:40","Revision":"","SHA1Sum":"b33aea7b6e52a29994bbaac60c0f744cff86bb76","SHA256Sum":"937ab75d649e4edc0330768dd08ff700235f962833ff4af75c9bd757dc323630","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen10 (U30) Servers"},{"Lang":"cn","Value":"用于 Linux 的 ROM Flash 组件 - HPE ProLiant DL380 Gen10 (U30) 服务器"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL380 Gen10(U30)サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-11T14:21:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3181c781c17f4f05bbf49bc628bfed5f"}]},{"ProductId":"270849c2dba647ceb1f5f641d466f681","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 9.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 9.0下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"},{"Lang":"ja","Value":"<p>この製品には、NICドライバーバージョン233.0.156.0とRoCEドライバーバージョン233.0.156.0が含まれています。</p>"},{"Lang":"cn","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"}],"Files":[{"Bytes":"385329","DateModified":"2025-10-02T08:11:56","FileList":["/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip","/cp068543.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/index.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_235.1.140.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_235.1.140.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtroce-3432817445946840263.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtnet-149725367173716768.xml","/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_235.1.240.0-1OEM.900.0.24755229.xml"],"MD5Sum":"b27df3eb2c38b85d796498dc45a206a3","Name":"cp068543.zip","Release":"2025-10-02T08:11:46","Revision":"","SHA1Sum":"0c5bff3fe4716ad90bca5cd8175ee17c28c49503","SHA256Sum":"3f1284f6ba0dc5a938ad009b6843c51b9bfd2ac2d3b047d19963c8084dd94929","Size":"376KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"bnxtnet","Version":"235.1.140.0-1OEM.900.0.24755229"},{"Name":"bnxtroce","Version":"235.1.140.0-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-27T06:17:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where ESXi Datastore not seen when NPAR is enabled.</li><li>This product fixes the issue where PSOD is seen when enable NPAR using 2 NICs.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、NPAR が有効な場合に ESXi データストアが表示されない問題を修正します。</li><li>この製品は、2 つの NIC を使用して NPAR を有効にすると PSOD が発生する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where ESXi Datastore not seen when NPAR is enabled.</li><li>This product fixes the issue where PSOD is seen when enable NPAR using 2 NICs.</li></ul>","Lang":"cn"}],"Version":"2025.05.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.11.00"}],"SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:235.1.240.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtroce:235.1.140.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtnet:235.1.140.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"108c2c6c505e48f1a6dd0e16f4cb61d5"}]},{"ProductId":"a4ccd8709d044858ab5bf64233046176","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM1 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM1_1.46_B.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901501000000","Version":"1.46"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains firmware for ProLiant Gen10Plus UBM1 storage backplanes. It can be installed online through the use of the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、ProLiant Gen10Plus UBM1ストレージバックプレーンのファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、iLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains firmware for ProLiant Gen10Plus UBM1 storage backplanes. It can be installed online through the use of the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"57567","DateModified":"2022-08-07T12:23:38","FileList":["HPE_UBM1_1.46_B.HPb","HPE_UBM1_1.46_B.xml","payload.json"],"MD5Sum":"8733243bab6e28ed811793d02a7a122c","Name":"HPE_UBM1_1.46_B.fwpkg","Release":"2022-09-13T00:00:00","Revision":"B","SHA1Sum":"50f0dd4496c424a52d57dd0bc37c0a7a2a91350f","SHA256Sum":"ec4e698d31c1155c25ae81dce5204accaff8c1bb0776f7b67c34fa9196d77a1b","Size":"56KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901501000000"],"TypeOfChange":"1","Version":"1.46"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - UBM1 Backplane PIC PLDM Firmware"},{"Lang":"ja","Value":"ファームウェアパッケージ - UBM1バックプレーンPIC PLDMファームウェア"},{"Lang":"cn","Value":"Firmware Package - UBM1 Backplane PIC PLDM Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901501000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-04-28T04:51:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.46"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>UBM FWPKGの初期バージョン。</li><li>RHEL9およびESXi8.0をサポート</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.46"}],"SWKeys":[{"Name":"UBM1PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"a663f1f50ce245ec806abddbf83cd919"}]},{"ProductId":"be8e1065c14f4a6883e7804dae8c691e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v4.00 (01/09/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v4.00 (01/09/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.00_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v4.00 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34090114","DateModified":"2026-01-12T20:53:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.00_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.00_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.00_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.00_2026_01_09-1.1/A43_4.00_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.00_2026_01_09-1.1/CP070349.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.00_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.00_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.00_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.00_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070349.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070349.scexe"],"MD5Sum":"9a3b1c20c851dbcc00964c7898f50f8f","Name":"firmware-system-a43-4.00_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T02:44:39","Revision":"","SHA1Sum":"24e8d5cf2cb30faa85b06b898408cafe22854904","SHA256Sum":"6f99718146166871c3a84a2113758959b03648e51b7cbdd8c17a10ebd45303bd","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"1","Version":"4.00_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus（A43）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T02:44:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMD参照コードMilanPI 1.0.0.Hが含まれています。</p><p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.H for AMD 3rd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.92_11-27-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.J for AMD 3rd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"4.00_01-09-2026"}],"SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ca788d17e6324d83b383b30df8423220"}]},{"ProductId":"5521a7a96ce64d8a92b5aab1a6147b6e","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-3052584b5243","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-3052584b5248","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-3052584b524b","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-3052584b5242","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-3052584b5244","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-3052584b5245","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MO000960RXKRC、MO001920RXKRH、MO003840RXKRK、VO000960RXKRB、VO001920RXKRD、およびVO003840RXKRE"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; This firmware version fixes a bug with the unmap command that may cause a drive hang<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; This firmware version fixes a bug with the unmap command that may cause a drive hang<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; This firmware version fixes a bug with the unmap command that may cause a drive hang<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2171292","DateModified":"2025-02-19T17:28:13","FileList":["payload.json","Seagate_LangeBP_SLNGBPHPESD5.HPb","Seagate_LangeBP_SLNGBPHPESD5.xml"],"MD5Sum":"8235c474155832e9fb1dea81d4556d0d","Name":"Seagate_LangeBP_SLNGBPHPESD5.fwpkg","Release":"2025-02-19T17:25:35","Revision":"B","SHA1Sum":"5d23f1d1eb610c65d8e1cf830c95697d0d9a44e7","SHA256Sum":"9ac1efce4d549b300896d3d3ad59f812085601f3ddf1684475267e661136ff23","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3936-3052584b5243","4d2340a5-304f-3130-3932-3052584b5248","4d2340a5-304f-3330-3834-3052584b524b","562340a5-304f-3030-3936-3052584b5242","562340a5-304f-3130-3932-3052584b5244","562340a5-304f-3330-3834-3052584b5245"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO000960RXKRC、MO001920RXKRH、MO003840RXKRK、VO000960RXKRB、VO001920RXKRD、およびVO003840RXKRE"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO000960RXKRC","TargetGUID":"4d2340a5-304f-3030-3936-3052584b5243","Type":"sas"},{"Id":"MO001920RXKRH","TargetGUID":"4d2340a5-304f-3130-3932-3052584b5248","Type":"sas"},{"Id":"MO003840RXKRK","TargetGUID":"4d2340a5-304f-3330-3834-3052584b524b","Type":"sas"},{"Id":"VO000960RXKRB","TargetGUID":"562340a5-304f-3030-3936-3052584b5242","Type":"sas"},{"Id":"VO001920RXKRD","TargetGUID":"562340a5-304f-3130-3932-3052584b5244","Type":"sas"},{"Id":"VO003840RXKRE","TargetGUID":"562340a5-304f-3330-3834-3052584b5245","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T18:26:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware version fixes a bug with the unmap command that may cause a drive hang</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware version fixes a bug with the unmap command that may cause a drive hang</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware version fixes a bug with the unmap command that may cause a drive hang</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MO000960RXKRC","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001920RXKRH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003840RXKRK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RXKRB","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RXKRD","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RXKRE","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"698b806535e54899a0d8cfa4fae3990c"}]},{"ProductId":"a730c4df025740309831b257ee5cb3dd","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4322512","DateModified":"2025-08-03T02:21:16","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-1.1/CP067351.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-1.1/SCIMARRNETG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067351.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067351.scexe"],"MD5Sum":"c4bbdd79d35b679b6131dd66252167a7","Name":"firmware-hdd-18e328f036_0HPG8-1.1_amd64.deb","Release":"2025-08-03T07:14:06","Revision":"","SHA1Sum":"7c3207bca9dc87d3bcc946d0ddffe2616f3293cb","SHA256Sum":"89b110cf2a29420bdacc5900ee32d42d29e289ce4b84c2bac87fb0f107c3a480","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"Installation":{"Command":"CP043252.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000GWWQU","TargetGUID":"4d2340a5-3042-3830-3030-304757575155","Type":"sata"},{"Id":"MB006000GWWQT","TargetGUID":"4d2340a5-3042-3630-3030-304757575154","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:43:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul>","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1011ccaa4aec47aa82b4a479e417e4e5"}]},{"ProductId":"d313ecbde1f54151bf42ad357e6b94ad","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A40_3.70_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.70 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"18034335","DateModified":"2026-01-14T02:07:04","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.70_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.70_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.70_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.70_2026_01_09-1.1/A40_3.70_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.70_2026_01_09-1.1/CP070205.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.70_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.70_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.70_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.70_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070205.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070205.scexe"],"MD5Sum":"3e6f404e77924870abf0f85f83923874","Name":"firmware-system-a40-3.70_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-14T07:56:00","Revision":"","SHA1Sum":"be7fc81064d555f33cf5d06370a62a82adf458f0","SHA256Sum":"5ca243aadb54911f8150b33965f8019d9b3c28c20c8fe60154f0ec89dac70f8e","Size":"17MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"1","Version":"3.70_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプすることにより、hpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL385 Gen10 (A40) Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL385 Gen10 (A40) サーバー "},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL385 Gen10 (A40) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-09T10:51:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>CVE-2025-3052を軽減するために、デフォルトのセキュアブートDBXをアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Nが含まれています。システムROMのこのリビジョンには、AMD第1世代EPYCプロセッサー用のAMDリファレンスコードNaplesPI 1.0.0.Rが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>Redfish経由でのBIOS設定の変更が、同じ起動中にBIOSアップデートが実行された場合に、失敗するという問題に対処しました。</p><p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated the default Secure Boot dbx to mitigate CVE-2025-3052.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.N for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.R for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where changing BIOS settings via Redfish would fail if a BIOS update was performed during the same boot.</p><p>Remove Expired SUSE and VMware Certificates.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_09-05-2025"},{"ReleaseNotes":[{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.</p><p></p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.P for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.S for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the SEV-SNP feature failed on AMD 2nd Generation \"Rome\" EPYC processors.</p><p>Addressed an issue where the iLO Remote Console could become unresponsive when a warning message appeared in the RBSU menu.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.70_01-09-2026"}],"SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"187f29f6e3d34ff2b6d40607c41795ed"}]},{"ProductId":"d8cf5e47a4564ba6bcb2ea1177a33ff1","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.54 (01/09/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.54 (01/09/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.54_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.54 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33604291","DateModified":"2026-01-12T06:59:57","FileList":["payload.json","U46_2.54_01_09_2026.signed.flash","U46_2.54_01_09_2026.xml"],"MD5Sum":"869fb60a2b971f4b395dc24958293ec6","Name":"U46_2.54_01_09_2026.fwpkg","Release":"2026-01-12T06:56:41","Revision":"","SHA1Sum":"d3eabd3e8202eeaf6c982f746e03bd155d36cd50","SHA256Sum":"a99ffd8154f06db9e653710f1e044bd8bfa321417fd8a6684bb584885c0f784f","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"1","Version":"2.54_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"},{"Lang":"ja","Value":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE ProLiant DL360/DL380 Gen10 Plus（U46）サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T05:54:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Whitley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.802（2.50_07_24_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Whitley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.50_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p><p>Added CPU C1 Auto Demotion/ UnDemotion option in System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.802 (2.50_07_24_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system PXE boot in legacy mode might fail when using the Intel I350-T4 OCP NIC.</p><p>Addressed an issue where the system might display spurious interrupt message during Linux boot up. </p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.54_01-09-2026"}],"SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"bdfb4e08a98a404e9f2f94a90fd34f11"}]},{"ProductId":"7fc78ba6f4174eae8b7e06638191844b","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b59464646","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b59464554","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b59464555","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b59464645","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b59464550","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b59464551","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3531-3336-304b59464552","Version":"HPK2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600KYFFF, MO003200KYFET, MO006400KYFEU, VO001920KYFFE, VO003840KYFEP, VO007680KYFEQ and VO015360KYFER"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO001600KYFFF, MO003200KYFET, MO006400KYFEU, VO001920KYFFE, VO003840KYFEP, VO007680KYFEQ and VO015360KYFER"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600KYFFF, MO003200KYFET, MO006400KYFEU, VO001920KYFFE, VO003840KYFEP, VO007680KYFEQ and VO015360KYFER"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This is a maintenance release that contains code fix improvements and drive function enhancements. Upgrading from HPK1 to HPK2 requires power cycle.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This is a maintenance release that contains code fix improvements and drive function enhancements. Upgrading from HPK1 to HPK2 requires power cycle.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>This is a maintenance release that contains code fix improvements and drive function enhancements. Upgrading from HPK1 to HPK2 requires power cycle.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"10048448","DateModified":"2025-06-16T19:52:13","FileList":["payload.json","SKHynix_PS10x0_KPS10x0U3DK2.HPb","SKHynix_PS10x0_KPS10x0U3DK2.xml"],"MD5Sum":"d2fcc71c73b2b14d6e06adc9f7564888","Name":"SKHynix_PS10x0_KPS10x0U3DK2.fwpkg","Release":"2025-06-16T19:49:59","Revision":"","SHA1Sum":"cad30730c0b85d575cc9ee0893c6611b7df1bf09","SHA256Sum":"e53a43bf535541a2b53adaf2d81abfa8c332c226b59efe94116ef9589f62e409","Size":"9MB","TargetGUIDs":["4d2340a5-304f-3130-3630-304b59464646","4d2340a5-304f-3330-3230-304b59464554","4d2340a5-304f-3630-3430-304b59464555","562340a5-304f-3130-3932-304b59464645","562340a5-304f-3330-3834-304b59464550","562340a5-304f-3730-3638-304b59464551","562340a5-304f-3531-3336-304b59464552"],"TypeOfChange":"1","Version":"HPK2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MO001600KYFFF, MO003200KYFET, MO006400KYFEU, VO001920KYFFE, VO003840KYFEP, VO007680KYFEQ and VO015360KYFER"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  MO001600KYFFF, MO003200KYFET, MO006400KYFEU, VO001920KYFFE, VO003840KYFEP, VO007680KYFEQ and VO015360KYFER"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MO001600KYFFF, MO003200KYFET, MO006400KYFEU, VO001920KYFFE, VO003840KYFEP, VO007680KYFEQ and VO015360KYFER"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO015360KYFER","TargetGUID":"562340a5-304f-3531-3336-304b59464552","Type":"nvme"},{"Id":"VO007680KYFEQ","TargetGUID":"562340a5-304f-3730-3638-304b59464551","Type":"nvme"},{"Id":"VO003840KYFEP","TargetGUID":"562340a5-304f-3330-3834-304b59464550","Type":"nvme"},{"Id":"VO001920KYFFE","TargetGUID":"562340a5-304f-3130-3932-304b59464645","Type":"nvme"},{"Id":"MO006400KYFEU","TargetGUID":"4d2340a5-304f-3630-3430-304b59464555","Type":"nvme"},{"Id":"MO003200KYFET","TargetGUID":"4d2340a5-304f-3330-3230-304b59464554","Type":"nvme"},{"Id":"MO001600KYFFF","TargetGUID":"4d2340a5-304f-3130-3630-304b59464646","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T19:11:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code fix improvements and drive function enhancements. Upgrading from HPK1 to HPK2 requires power cycle.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code fix improvements and drive function enhancements. Upgrading from HPK1 to HPK2 requires power cycle.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code fix improvements and drive function enhancements. Upgrading from HPK1 to HPK2 requires power cycle.</li></ul>","Lang":"cn"}],"Version":"HPK2"}],"SWKeys":[{"Name":"MO001600KYFFF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYFET","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYFEU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYFFE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYFEP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYFEQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYFER","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"cf0615bbfbbd47ed854ab307d9a173f5"}]},{"ProductId":"dd0182917bf14543bf436162a2a05331","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000JXMTH and MB020000JXMTP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB018000JXMTHおよびMB020000JXMTP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6218179","DateModified":"2025-09-17T11:34:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/CP068840.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/SLONGSPKESD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068840.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068840.scexe"],"MD5Sum":"df92047d284b8576469976a26c57a736","Name":"firmware-hdd-020fc874ad-HPD3-3.1.x86_64.rpm","Release":"2025-09-17T16:25:04","Revision":"C","SHA1Sum":"58931f3ff064143a8e6620e52e79e79a612830f1","SHA256Sum":"6fdfc86e270ceb9f9abf27852270a0946fe4c2258c57a5b1f3c24543d0d78f48","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP041696.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000JXMTH and MB020000JXMTP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB018000JXMTHおよびMB020000JXMTPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB020000JXMTP","TargetGUID":"4d2340a5-3042-3032-3030-304a584d5450","Type":"sas"},{"Id":"MB018000JXMTH","TargetGUID":"4d2340a5-3042-3831-3030-304a584d5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T17:56:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"46f9341a20c14989b9f4611fd9c3e917"}]},{"ProductId":"acccc3a79b934a56bc23c6e1a1b8169b","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30525a575550","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30525a575551","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30525a575552","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30525a575556","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30525a575554","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30525a575641","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30525a575555","Version":"HPD1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU "},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。VO000960RZWUP、VO000960RZWUQ、VO001920RZWUR、VO001920RZWUV、VO003840RZWUT、VO003840RZWVA、およびVO007680RZWUU "},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This fix is for unrecovered errors may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付：<br />     </strong>HPD1</p><p><strong>最新の推奨またはクリティカルバージョン：</strong><br />     なし</p><p><strong>前のファームウェアバージョン：</strong><br />     なし</p><p><strong>機能強化/新しい機能:</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li><p>この修正は、ホストが読み取りコマンドを発行したときに、ウェアレベリングプロセスの対象ブロックで回復不能なエラーが発生する可能性がある場合に行われます。</p></li></ul><p><strong>既知の問題点:</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This fix is for unrecovered errors may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1158118","DateModified":"2025-02-19T16:21:18","FileList":["Kioxia_RM6_KARM6ALSHPD1.HPb","Kioxia_RM6_KARM6ALSHPD1.xml","payload.json"],"MD5Sum":"03fbf80e11569463731364bb3f790bb4","Name":"Kioxia_RM6_KARM6ALSHPD1.fwpkg","Release":"2025-02-19T16:18:49","Revision":"B","SHA1Sum":"cf427842c7a2529914edf395b4b2de49317e46af","SHA256Sum":"7aa9bfd38c3345367cf5ea56ccbfd853b81a59a92dc9c9a262f3edd4242dcecc","Size":"1MB","TargetGUIDs":["562340a5-304f-3030-3936-30525a575550","562340a5-304f-3030-3936-30525a575551","562340a5-304f-3130-3932-30525a575552","562340a5-304f-3130-3932-30525a575556","562340a5-304f-3330-3834-30525a575554","562340a5-304f-3330-3834-30525a575641","562340a5-304f-3730-3638-30525a575555"],"TypeOfChange":"1","Version":"HPD1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - VO000960RZWUP、VO000960RZWUQ、VO001920RZWUR、VO001920RZWUV、VO003840RZWUT、VO003840RZWVA、およびVO007680RZWUU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO000960RZWUP","TargetGUID":"562340a5-304f-3030-3936-30525a575550","Type":"sas"},{"Id":"VO000960RZWUQ","TargetGUID":"562340a5-304f-3030-3936-30525a575551","Type":"sas"},{"Id":"VO001920RZWUR","TargetGUID":"562340a5-304f-3130-3932-30525a575552","Type":"sas"},{"Id":"VO001920RZWUV","TargetGUID":"562340a5-304f-3130-3932-30525a575556","Type":"sas"},{"Id":"VO003840RZWUT","TargetGUID":"562340a5-304f-3330-3834-30525a575554","Type":"sas"},{"Id":"VO003840RZWVA","TargetGUID":"562340a5-304f-3330-3834-30525a575641","Type":"sas"},{"Id":"VO007680RZWUU","TargetGUID":"562340a5-304f-3730-3638-30525a575555","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T15:36:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This fix is for unrecovered errors may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この修正は、ホストが読み取りコマンドを発行したときに、ウェアレベリングプロセスの対象ブロックで回復不能なエラーが発生する可能性がある場合に行われます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This fix is for unrecovered errors may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul>","Lang":"cn"}],"Version":"HPD1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD1"}],"SWKeys":[{"Name":"VO007680RZWUU","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RZWVA","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RZWUT","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RZWUV","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RZWUR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RZWUQ","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RZWUP","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"9f078413ab6e4fb6aeab7cecca2f01a6"}]},{"ProductId":"8adcf62d3b4a41379b595de71bd60c8d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Assert fixes, logging enhancements and all current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Assert fixes, logging enhancements and all current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4602716","DateModified":"2025-08-02T20:52:33","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-1.1/CP067360.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-1.1/SHPEEVSBPSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067360.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067360.scexe"],"MD5Sum":"5ccb2cb28a5de908df0ef1aa347b5d2b","Name":"firmware-hdd-8173816d98_0HPD6-1.1_amd64.deb","Release":"2025-08-03T01:43:52","Revision":"","SHA1Sum":"4f74a9250faffb4367bc46ff79634a020cf2fa09","SHA256Sum":"8a8c4dee543ca061cb4528b1340349881da8c26d7c098f8511ad5612c74133b4","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000JYDKK","TargetGUID":"4d2340a5-3042-3031-3030-304a59444b4b","Type":"sas"},{"Id":"MB012000JYCJF","TargetGUID":"4d2340a5-3042-3231-3030-304a59434a46","Type":"sas"},{"Id":"MB014000JYCJV","TargetGUID":"4d2340a5-3042-3431-3030-304a59434a56","Type":"sas"},{"Id":"MB016000JYDKL","TargetGUID":"4d2340a5-3042-3631-3030-304a59444b4c","Type":"sas"},{"Id":"MB018000JYDKN","TargetGUID":"4d2340a5-3042-3831-3030-304a59444b4e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:59:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>A Drive Firmware enhancement has been made to reduce the probability of infrequent, unexpected power loss on some backed drives in Primera 600 LFF enclosure.</li></ul>","Lang":"cn"}],"Version":"HPD6"}],"SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1efea56866214eb8ab1656c678923749"}]},{"ProductId":"8bcfdc333663490ba14bb0a7e2286062","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8276526","DateModified":"2025-12-19T12:12:21","FileList":["/CP069048_BUILD_1.data","/CP069048.vmcfg","/CP069048.vmexe64","/CP069048.vmfile","/CP069048_VMw.zip","/CP069048.xml","/payload.json","/CP069048_VMw.zip/index.xml","/CP069048_VMw.zip/vendor-index.xml","/CP069048_VMw.zip/metadata.zip","/CP069048_VMw.zip/vib20/CP069048/HPE_bootbank_CP069048_2.74.1-8.0.0.20613240.vib","/CP069048_VMw.zip/metadata.zip/vendor-index.xml","/CP069048_VMw.zip/metadata.zip/vmware.xml","/CP069048_VMw.zip/metadata.zip/vibs/CP069048-8730783112776095191.xml","/CP069048_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069048_2.74.1-8.0.0.20613240.xml"],"MD5Sum":"2af8e7ffe630b75875ad2e3c02b7e49e","Name":"CP069048.zip","Release":"2025-12-19T12:09:13","Revision":"U","SHA1Sum":"e0fde8f1eb7f532a78526432d8ec00ead4f55fe0","SHA256Sum":"26775dfca66ae5365e2a6e80fa2af59c0f776a03bafb13ac47185d546fbc450f","Size":"7MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74","VibList":[{"Name":"CP069048","Version":"2.74.1-8.0.0.20613240"}]}],"Installation":{"Command":"setup","CommandParams":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"ja","Value":"HPE D6020 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"},{"Lang":"cn","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D6020","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-06T08:18:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li>gSEPモデルとSESデータベース内の温度センサーロジック</li><li>IOMが引き出されたときに、残っているIOMが正しくない異常温度を報告する</li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"},{"ReleaseNotes":[{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p>ESXi 9.0のサポートを追加しました</p><p>ESXi 7.0のサポートを削除しました</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v275182/20-D6020-Gen10RN274V_ED20.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"}],"SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"abc96569b95b454ba4dd8f87cbe93681"}]},{"ProductId":"85a59acb7d634eb691745a6c9906ad03","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Management"},{"Lang":"ja","Value":"ソフトウェア - マネジメント"},{"Lang":"cn","Value":"软件 - 管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."},{"Lang":"ja","Value":"Smart Storage Administrator CLIは、SmartアレイコントローラーおよびSmartRAIDコントローラー用のコマンドラインベースのディスク構成プログラムです。"},{"Lang":"cn","Value":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"12752207","DateModified":"2025-12-08T07:03:16","FileList":["/cp069349.xml","/MIS_bootbank_ssacli2_6.60.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.zip","/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.zip/index.xml","/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.zip/vendor-index.xml","/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.zip/metadata.zip","/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.60.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/ssacli2-364449052458415762.xml","/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/ssacli2-component_6.60.11.0-1OEM.900.0.24755229.xml"],"MD5Sum":"c75880d1a5576eebd3ca7d240c9e893a","Name":"cp069349.zip","Release":"2025-12-08T07:01:59","Revision":"","SHA1Sum":"f1949ba6455c1f8722ff62382733c1d6e2cdb9b4","SHA256Sum":"b879b3b6dce31db024c6d84b36f718c63cb30273d7d9c807c5b113579238562c","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2026.03.01","VibList":[{"Name":"ssacli2","Version":"6.60.11.0-1OEM.900.0.24755229"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>New Installation<br />-----------------</p><p>Issue the following command (full path to the file must be specified):<br />esxcli software component apply&nbsp;{File}</p><p>&nbsp;</p><p>Upgrade Installation<br />----------------------<br />The upgrade process is similar to a new install as the same command upgrades the component to a newer,&nbsp;if the prior version is already installed on ESXi server.<br />esxcli software component apply -d {File}</p><p>&nbsp;</p><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"ja","Value":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>New Installation<br />-----------------</p><p>Issue the following command (full path to the file must be specified):<br />esxcli software component apply&nbsp;{File}</p><p>&nbsp;</p><p>Upgrade Installation<br />----------------------<br />The upgrade process is similar to a new install as the same command upgrades the component to a newer,&nbsp;if the prior version is already installed on ESXi server.<br />esxcli software component apply -d {File}</p><p>&nbsp;</p><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>New Installation<br />-----------------</p><p>Issue the following command (full path to the file must be specified):<br />esxcli software component apply&nbsp;{File}</p><p>&nbsp;</p><p>Upgrade Installation<br />----------------------<br />The upgrade process is similar to a new install as the same command upgrades the component to a newer,&nbsp;if the prior version is already installed on ESXi server.<br />esxcli software component apply -d {File}</p><p>&nbsp;</p><p>Refer to VMware documentation for information on the esxcli commands</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 9.0 for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) CLI Smartコンポーネントfor ESXi 9.0 for Gen10/Gen10 Plus/Gen11コントローラー"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 9.0 for Gen10/Gen10 Plus/Gen11 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"7100"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-04T06:20:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for VMware ESXi 9.0&nbsp;</li></ul>","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>VMware ESXi 9.0のサポートを追加しました </li></ul>","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for VMware ESXi 9.0&nbsp;</li></ul>","Fixes":"<ul><li>Fixed the &ldquo;Parity Initialization Method&rdquo; information displayed for non-parity RAID levels.&nbsp;</li><li>Fixed an issue where users were unable to clear the controller&rsquo;s configuration when a foreign volume was present.&nbsp;</li><li>Fixed an issue where a foreign-owned SED drive was being listed for array creation.&nbsp;</li><li>Fixed an issue where the last failure reason was not listing on physical drives.&nbsp;</li><li>Fixed an issue where SSAScripting failed to create an encrypted volume while in express local mode.&nbsp;</li><li>Fixed an issue where an error/warning message was not being generated correctly while expanding a RAID 1+0 volume.&nbsp;</li><li>Fixed an issue where a duplicate entry for the physical drive was displayed.&nbsp;</li></ul>","Lang":"cn"}],"Version":"2025.09.01"},{"ReleaseNotes":[{"Enhancements":"<p>Signed drop&nbsp;6.60.11.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Signed drop&nbsp;6.60.11.0</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Signed drop&nbsp;6.60.11.0</p>","Fixes":"","Lang":"cn"}],"Version":"2026.03.01"}],"SWKeys":[{"Name":"ssacli2-component:6.60.11.0-1OEM.900.0.24755229","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.60.11.0-1OEM.900.0.24755229","SWKeyExpectedPath":"software:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL215n Gen10 Plus"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6b15829f58204225911f6452976f1aa8"}]},{"ProductId":"263869a9bde4406ca10c065a64fecfad","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000GXMTK and MB020000GXMTQ"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000GXMTK and MB020000GXMTQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64) - MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4338400","DateModified":"2025-08-02T20:58:49","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-1.1/CP067362.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-1.1/SLONGSPKETG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067362.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067362.scexe"],"MD5Sum":"3cbbd275c740ef83207222c33608a48e","Name":"firmware-hdd-3496cc4743_0HPG3-1.1_amd64.deb","Release":"2025-08-03T01:52:44","Revision":"","SHA1Sum":"0535c311bc242391fb7567b1058dddab5e311349","SHA256Sum":"7e3be6518d6a314bfca498634f09a9c1ca16f11e36a2260de09fa67939211787","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP041696.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MB018000GXMTK and MB020000GXMTQ Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MB018000GXMTK and MB020000GXMTQ Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB020000GXMTQ","TargetGUID":"4d2340a5-3042-3032-3030-3047584d5451","Type":"sata"},{"Id":"MB018000GXMTK","TargetGUID":"4d2340a5-3042-3831-3030-3047584d544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T13:01:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"594982095a0546c481633bb1c1120d4d"}]},{"ProductId":"672edcd2af9a4bd18876e5e3192cd831","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U40_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11842035","DateModified":"2026-01-12T21:58:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.62_2026_01_09-1.1/CP070358.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.62_2026_01_09-1.1/U40_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070358.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070358.scexe"],"MD5Sum":"4c904c49a01b638bda769e3d565bd561","Name":"firmware-system-u40-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-13T03:47:55","Revision":"","SHA1Sum":"b64acf5955de78f544d5101df1a3394c660f995e","SHA256Sum":"984861b29bf4ddbf1ffde7ec0e9404839ca5dd2ff59a830e9ef94a566575cfb5","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合:<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:45:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e09234a0cb084d84ae324b9ac53e40a4"}]},{"ProductId":"74b3fe77108f45dc915915f121f04357","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"859285","DateModified":"2025-11-18T08:27:18","FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/elx-lpfc","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"MD5Sum":"f5c96c9d1eda5a410cb771bf64f76f43","Name":"kmod-elx-lpfc-14.4.731.6-1.rhel10u1.x86_64.rpm","Release":"2025-11-18T08:22:04","Revision":"","SHA1Sum":"8475fda78c64badd39641b584ac95b4660d693bf","SHA256Sum":"8555eda5eb4dc96611faff31889f5c6272356b88ba2516c1241472885e4b4775","Size":"839KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.6"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.4.705.0-1.rhel10u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.4.705.0-1.rhel10u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.4.705.0-1.rhel10u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 10 Server Update 1 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 10 Server Update 1 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 10 Server Update 1 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-26T05:06:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10.0</p><p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"},{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.1</p><p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.1</p><p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.1</p><p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.731.6"}],"SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7647aad973dc463d88c46a6ab6c0366d"}]},{"ProductId":"11da5efc39044b5bb1d1491457b48fdd","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Ubuntu Linux (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4229484","DateModified":"2025-08-02T19:58:37","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-1.1/CP067352.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-1.1/SCIMARRNNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067352.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067352.scexe"],"MD5Sum":"6d25f179cb90e2600c2f0aca05b2d9ff","Name":"firmware-hdd-12304c1aca_0HPG6-1.1_amd64.deb","Release":"2025-08-03T00:49:54","Revision":"","SHA1Sum":"359ec70a19721365a907fef309e973a7a1295629","SHA256Sum":"26ea2e23d6a49833143030f13dc2a48189295d9ad3841ebbd24503a82c536f1e","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP043255.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000GWWQH","TargetGUID":"4d2340a5-3042-3430-3030-304757575148","Type":"sata"},{"Id":"MB002000GWWQF","TargetGUID":"4d2340a5-3042-3230-3030-304757575146","Type":"sata"},{"Id":"MB001000GWWQE","TargetGUID":"4d2340a5-3042-3130-3030-304757575145","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T12:44:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul>","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"eb7ff89f1b6a4466b34d0dee0b507986"}]},{"ProductId":"4cf79b782386458fa01aea2ca94f4962","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware addresses a hot plug reporting concern</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware addresses a hot plug reporting concern</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5584815","DateModified":"2025-09-21T22:25:20","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1/CP068934.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1/SAVNGSDA.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068934.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068934.scexe"],"MD5Sum":"7404b434beb6e891c378a858d8ada62e","Name":"firmware-hdd-b04257b77b-HPDA-7.1.x86_64.rpm","Release":"2025-09-22T03:14:07","Revision":"G","SHA1Sum":"f53a5b30e7dd35515bb5964a7e67f0781a8bceba","SHA256Sum":"9c7c70ddc66517d9f42a99a3c11354b443fccf31e240d2bccf9d1f68bb40ab5b","Size":"5MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"TypeOfChange":"1","Version":"HPDA"}],"Installation":{"Command":"CP040271.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MM1000JEFRB and MM2000JEFRC Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM1000JEFRB","TargetGUID":"002340a5-4d00-314d-3030-304a45465242","Type":"sas"},{"Id":"MM2000JEFRC","TargetGUID":"002340a5-4d00-324d-3030-304a45465243","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:16:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDA"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Firmware addresses a hot plug reporting concern</li></ul>","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"MM1000JEFRB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MM2000JEFRC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"740138d8fd3b4dc695032808f4b040d1"}]},{"ProductId":"923bb6bba3254a6d80257c1bf056f39d","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM6 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM6_1.06_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"9675b54e-1c96-44c3-a7a1-901506000000","Version":"1.06"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains PLDM firmware for UBM6 storage backplanes."},{"Lang":"ja","Value":"このファームウェアパッケージには、UBM6ストレージバックプレーンのPLDMファームウェアが含まれています。"},{"Lang":"cn","Value":"This firmware package contains PLDM firmware for UBM6 storage backplanes."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"131393","DateModified":"2025-11-06T01:02:20","FileList":["HPE_UBM6_1.06_A.HPb","HPE_UBM6_1.06_A.xml","payload.json"],"MD5Sum":"bb281ebaeed195a1fe0759a768371a32","Name":"HPE_UBM6_1.06_A.fwpkg","Release":"2025-11-06T01:00:03","Revision":"C","SHA1Sum":"56cbc2c8a4f62fb636f057be45f406683a7ae465","SHA256Sum":"df08ac1cfa765c1ab04a7f11a308787701a19f713942cdc4c918ec7a49ee6734","Size":"128KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901506000000"],"TypeOfChange":"1","Version":"1.06"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>    ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"[Internal] Firmware Package - UBM6 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11/Gen12 servers usage"},{"Lang":"ja","Value":"[Internal] Firmware Package - UBM6 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11/Gen12 servers usage"},{"Lang":"cn","Value":"[Internal] Firmware Package - UBM6 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11/Gen12 servers usage"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901506000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-05T03:01:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support SY480 Gen12 server.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>SY480 Gen12 サーバーをサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support SY480 Gen12 server.</p>","Fixes":"","Lang":"cn"}],"Version":"1.04"},{"ReleaseNotes":[{"Enhancements":"<p>Private release for specific customers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Private release for specific customers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Private release for specific customers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.06"}],"SWKeys":[{"Name":"UBM6PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"R11","Model":"HPE ProLiant RL300 Gen11"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"7b7e1b259798400e9d831a9ae7dc63e5"}]},{"ProductId":"7a38c76de8ff4383970907d2998b1740","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1041896","DateModified":"2025-11-16T04:53:17","FileList":["cp069549.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"MD5Sum":"2a38cb849a7b100182f392d7e35b4cd7","Name":"cp069549.exe","Release":"2025-11-16T04:39:25","Revision":"B","SHA1Sum":"bebf37bcee88bd5bdf3a20b720e7ec020f97626d","SHA256Sum":"a81f4073aef93752777eccaf61efe595c00ac50cc335a13c1485739263db2f41","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"TypeOfChange":"1","Version":"4.1.254.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixn Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel ixnドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel ixn Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、新しいファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"4.1.254.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、新しいファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"4.1.254.0"}],"SWKeys":[{"Name":"ixn68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"0c703a78e2174310a9807b7cb69ced22"}]},{"ProductId":"d0558c4ca40d4c1889688fd366d72022","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"18906761","DateModified":"2025-03-26T12:41:39","FileList":["/CP066510_BUILD_1.data","/CP066510.vmexe64","/CP066510.vmfile","/CP066510_VMw.zip","/CP066510.xml","/payload.json","/CP066510_VMw.zip/index.xml","/CP066510_VMw.zip/vendor-index.xml","/CP066510_VMw.zip/metadata.zip","/CP066510_VMw.zip/vib20/CP066510/HPE_bootbank_CP066510_HPD2.1-8.0.0.20613240.vib","/CP066510_VMw.zip/metadata.zip/vendor-index.xml","/CP066510_VMw.zip/metadata.zip/vmware.xml","/CP066510_VMw.zip/metadata.zip/vibs/CP066510--8148657513295225398.xml","/CP066510_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066510_HPD2.1-8.0.0.20613240.xml"],"MD5Sum":"23148a8c6fe80c4089d24ad425f10abd","Name":"CP066510.zip","Release":"2025-03-26T12:40:48","Revision":"B","SHA1Sum":"dcfdcd020a1469392d9a5af276019d844b2b9fc7","SHA256Sum":"e39f8986131a13979bc72f846b18a7a717eef64854059481c3cebca98315cdc1","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"2","Version":"HPD2","VibList":[{"Name":"CP066510","Version":"HPD2.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP040573.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MO000800JXBEV","TargetGUID":"4d2340a5-304f-3030-3830-304a58424556","Type":"sas"},{"Id":"MO001600JXBFP","TargetGUID":"4d2340a5-304f-3130-3630-304a58424650","Type":"sas"},{"Id":"MO003200JXBFQ","TargetGUID":"4d2340a5-304f-3330-3230-304a58424651","Type":"sas"},{"Id":"MO006400JXBFR","TargetGUID":"4d2340a5-304f-3630-3430-304a58424652","Type":"sas"},{"Id":"MO000960JXBFA","TargetGUID":"4d2340a5-304f-3030-3936-304a58424641","Type":"sas"},{"Id":"MO001920JXBFT","TargetGUID":"4d2340a5-304f-3130-3932-304a58424654","Type":"sas"},{"Id":"MO003840JXBFU","TargetGUID":"4d2340a5-304f-3330-3834-304a58424655","Type":"sas"},{"Id":"MO007680JXBGA","TargetGUID":"4d2340a5-304f-3730-3638-304a58424741","Type":"sas"},{"Id":"MO015360JXBFV","TargetGUID":"4d2340a5-304f-3531-3336-304a58424656","Type":"sas"},{"Id":"EO000400JXBEU","TargetGUID":"452340a5-304f-3030-3430-304a58424555","Type":"sas"},{"Id":"EO000800JXBFL","TargetGUID":"452340a5-304f-3030-3830-304a5842464c","Type":"sas"},{"Id":"EO001600JXBFN","TargetGUID":"452340a5-304f-3130-3630-304a5842464e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T20:50:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、CBが次のURLで公開されています。https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4d4eeb5fca8642ac80b8d8ba61ff0ffb"}]},{"ProductId":"d5dd0878f5bc46a1b2bda19d450bbffe","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-3050584d544e","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-3050584d5456","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-3050584d5541","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-3050584d544c","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-3050584d5452","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-3050584d5454","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-3050584d5455","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MO001600PXMTN、MO003200PXMTV、MO006400PXMUA、VO001920PXMTL、VO003840PXMTR、VO007680PXMTT、およびVO015360PXMTU"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; To fix 1) chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2 and 2) garbage collection checking for performance recovery.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; To fix 1) chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2 and 2) garbage collection checking for performance recovery.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; To fix 1) chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2 and 2) garbage collection checking for performance recovery.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1576209","DateModified":"2025-07-03T15:07:23","FileList":["Kioxia_PM7_KAPM7ALSHPD4.HPb","Kioxia_PM7_KAPM7ALSHPD4.xml","payload.json"],"MD5Sum":"365fdadcfc92046b21a4a4dc08e8bb58","Name":"Kioxia_PM7_KAPM7ALSHPD4.fwpkg","Release":"2025-07-03T15:04:51","Revision":"","SHA1Sum":"8ffe7e5833092e4d4e0b4d96f87b73cabca0792e","SHA256Sum":"f46078c7a23e28323964baeab66839462e839feebb14d388c369f1683232cac5","Size":"1MB","TargetGUIDs":["4d2340a5-304f-3130-3630-3050584d544e","4d2340a5-304f-3330-3230-3050584d5456","4d2340a5-304f-3630-3430-3050584d5541","562340a5-304f-3130-3932-3050584d544c","562340a5-304f-3330-3834-3050584d5452","562340a5-304f-3730-3638-3050584d5454","562340a5-304f-3531-3336-3050584d5455"],"TypeOfChange":"2","Version":"HPD4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO001600PXMTN、MO003200PXMTV、MO006400PXMUA、VO001920PXMTL、VO003840PXMTR、VO007680PXMTT、およびVO015360PXMTU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO015360PXMTU","TargetGUID":"562340a5-304f-3531-3336-3050584d5455","Type":"sas"},{"Id":"VO007680PXMTT","TargetGUID":"562340a5-304f-3730-3638-3050584d5454","Type":"sas"},{"Id":"VO003840PXMTR","TargetGUID":"562340a5-304f-3330-3834-3050584d5452","Type":"sas"},{"Id":"VO001920PXMTL","TargetGUID":"562340a5-304f-3130-3932-3050584d544c","Type":"sas"},{"Id":"MO006400PXMUA","TargetGUID":"4d2340a5-304f-3630-3430-3050584d5541","Type":"sas"},{"Id":"MO003200PXMTV","TargetGUID":"4d2340a5-304f-3330-3230-3050584d5456","Type":"sas"},{"Id":"MO001600PXMTN","TargetGUID":"4d2340a5-304f-3130-3630-3050584d544e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-02T02:21:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li><li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us\" id=\"menur2cjc\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00146367en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us</a> which will be active on 20-Mar-2025.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブヘルスのクエリが誤ったドライブ予測エラーを引き起こす可能性がある稀なケースに対処するための修正を追加しました。</li><li>詳しくは、HPEカスタマーアドバイザリ：<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us\" id=\"menur2cjc\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00146367en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us</a> (2025年3月20日から有効) を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li><li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us\" id=\"menur2cjc\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00146367en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us</a> which will be active on 20-Mar-2025.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>To fix 1) chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2 and 2) garbage collection checking for performance recovery.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>To fix 1) chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2 and 2) garbage collection checking for performance recovery.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>To fix 1) chip kill -The host IO CMD may get timed out and shows SNS=04/40/C2 and 2) garbage collection checking for performance recovery.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO001600PXMTN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003200PXMTV","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO006400PXMUA","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920PXMTL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PXMTR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PXMTT","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO015360PXMTU","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"773c466c982042fea8769d7ddbc070dd"}]},{"ProductId":"f6fccbc5aefd411688310b509bfaeaec","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000GXMTK and MB020000GXMTQ"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB018000GXMTKおよびMB020000GXMTQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5907557","DateModified":"2025-12-02T01:49:51","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/CP068841.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/SLONGSPKETG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068841.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068841.scexe"],"MD5Sum":"93e7a55162e78de2cda9e2dbe2e58bbd","Name":"firmware-hdd-3496cc4743-HPG3-3.1.x86_64.rpm","Release":"2025-12-02T07:41:16","Revision":"C","SHA1Sum":"e0e96f283f0c4124acba8b2db0857916d92d2902","SHA256Sum":"9d791e64373b8d8fd4a0efea711dae81bc021f90392364e2162b0600d7334f31","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP041696.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000GXMTK and MB020000GXMTQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB018000GXMTKおよびMB020000GXMTQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB020000GXMTQ","TargetGUID":"4d2340a5-3042-3032-3030-3047584d5451","Type":"sata"},{"Id":"MB018000GXMTK","TargetGUID":"4d2340a5-3042-3831-3030-3047584d544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T17:57:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SLES16のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"65c8ee31d6f74304bdfd954b3fb127a3"}]},{"ProductId":"25bee0f636714c0e8bface2301234fec","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_8002-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8002"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_8002-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8002"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_8002-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8002"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Windows x86_64 platform."},{"Lang":"ja","Value":"このパッケージは、Windows x86_64プラットフォーム上でHPE VPI (EthernetおよびInfinibandモードで動作) ConnectX6デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.8002</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.8002</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.8002</td><td>HPE0000000036</td></tr></tbody></table>"}],"Files":[{"Bytes":"29351888","DateModified":"2025-12-02T10:06:54","FileList":["cp069135.xml","cpqsetup.exe","fw-ConnectX6-rel-20_43_8002-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","fw-ConnectX6-rel-20_43_8002-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","fw-ConnectX6-rel-20_43_8002-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"7fb98c67119909e84e1d72c349337b3f","Name":"cp069135.exe","Release":"2025-12-02T10:05:20","Revision":"","SHA1Sum":"9647f0ae7bc5a56775043c2e634063a7304d52db","SHA256Sum":"453b63dce42e484b1e5b166a2518c996e5a8fea4fa394b4d35bd3f572a66a7af","Size":"27MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.0.15"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Windows x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ (Windows x64) for HPE  NVIDIA VPI (EthernetおよびInfinibandモード) ConnectX4デバイス - Windows x86_64プラットフォーム"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-09T06:34:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが20.43.2566にアップデートされました。</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-HDATアダプター- P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-ECATアダプター- P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe3 x16 MCX653106A-ECATアダプター- P06251-B21</li></ul><p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン20.43.2566には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2566で修正されました：</strong></p><ul><li>SMPアクセスレジスターMADの使用時にSLRGレジスターが読み取り不能になる問題を解決しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"1.0.0.14"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.8002には、以下の新機能と変更が含まれます。</strong></p><ul><li>このリリースには、重要な信頼性の向上とセキュリティ強化の機能強化が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン20.43.8002で修正されました：</strong></p><ul><li>DIMを有効にすると、特定のシナリオでIRQ/sが高くなります。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 20.43.8002:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.8002:</strong></p><ul><li>Enabling DIM led to high IRQ/s in certain scenarios.</li></ul>","Lang":"cn"}],"Version":"1.0.0.15"}],"SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"50614c2a24d44149a348e14e1aea3cc2"}]},{"ProductId":"ac4d46dcda694f51abe34e6378a53487","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8002-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8002"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1908"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1908-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1908"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 8.0."},{"Lang":"ja","Value":"このパッケージは、ESXi 8.0.上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1908</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1908</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.8002</td><td>HPE0000000014</td></tr></tbody></table>"}],"Files":[{"Bytes":"27200613","DateModified":"2025-10-15T05:23:56","FileList":["/CP069157.vmexe64","/CP069157.vmfile","/CP069157.xml","/CP069157_VMw.zip","/payload.json","/CP069157_VMw.zip/index.xml","/CP069157_VMw.zip/vendor-index.xml","/CP069157_VMw.zip/metadata.zip","/CP069157_VMw.zip/vib20/CP069157/HPE_bootbank_CP069157_1.0.0-8.0.0.21495797.vib","/CP069157_VMw.zip/metadata.zip/vendor-index.xml","/CP069157_VMw.zip/metadata.zip/vmware.xml","/CP069157_VMw.zip/metadata.zip/vibs/CP069157-6211701096028560910.xml","/CP069157_VMw.zip/metadata.zip/bulletins/Smart-Component-CP069157_1.0.0-8.0.0.21495797.xml"],"MD5Sum":"6fc069c6c82ac97f6e52d11377ac03bf","Name":"CP069157.zip","Release":"2025-10-15T05:24:33","Revision":"","SHA1Sum":"8b3b239e59d5d2eddcf9a6536b8fe99b667d048a","SHA256Sum":"423612ebc5ef75915a1f8b61faa029bebd9dd704a147016bca502c0657797c95","Size":"25MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.7","VibList":[{"Name":"CP069157","Version":"1.0.0-8.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します。 <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox Ethernet only adapters"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(ESXi 8.0) for HPE Mellanox Ethernetアダプター専用"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox Ethernet only adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-10T10:51:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1904にアップデートされました。</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2ポート640FLR-SFP28アダプター)</li><li>817753-B21 (HPE Ethernet 25Gb 2ポート640SFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4506にアップデートされました。</strong></p><ul><li>874253-B21（HPE Ethernet 100Gb 1ポート842QSFP28アダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1904には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>バージョン16.35.4506には、以下の新機能と変更が含まれます。</strong></p><ul><li>MLNX OEM CMD 0x0032 (デバッグ情報の取得) に、4バイト境界となるようにアドレス検証を追加しました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアのバージョン14.32.1904で修正されました：</strong></p><ul><li>QoS設定がないと、接続が中断され、パケットがドロップされます。</li></ul><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4506で修正されました：</strong></p><ul><li>GLOBAL一時停止機能が無効になっている場合、不正なMPLSパケット破棄フローが発生していました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1904:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1904.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version&nbsp;14.32.1904:</strong></p><ul><li>Missing QoS settings caused connectivity disruptions and packet drops.</li></ul><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.6"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1908:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.8002:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1908:</strong></p><ul><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul><p><strong>New features and changes included in version 16.35.8002:</strong></p><ul><li>Enhanced performance of firmware exception path handling to better support increased numbers of configured SR-IOV instances.</li><li>This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.</li></ul>","Fixes":"<p><strong>No fixes are included in version 14.32.1908.</strong></p><p><strong>The following issues have been fixed in version 16.35.8002:</strong></p><ul><li>Firmware failed to scan the correct CQs for the PF after the FW entered into the CQ recovery mode., resulting in CQs for the PF not being recovered.</li></ul>","Lang":"cn"}],"Version":"1.0.7"}],"SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d0e2107598234bfaa671aaf70e77861d"}]},{"ProductId":"cfe4c5a213fb4be397a8b588efd29cc1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB006000GWKGR"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000GWKGR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p><p><strong>Previous Version of Firmware:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;</p><ul><li>&nbsp; &nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p><p><strong>Previous Version of Firmware:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;</p><ul><li>&nbsp; &nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20646243","DateModified":"2025-03-07T06:34:19","FileList":["/CP065934_BUILD_3.data","/CP065934.vmexe64","/CP065934.vmfile","/CP065934_VMw.zip","/CP065934.xml","/payload.json","/CP065934_VMw.zip/index.xml","/CP065934_VMw.zip/vendor-index.xml","/CP065934_VMw.zip/metadata.zip","/CP065934_VMw.zip/vib20/CP065934/HPE_bootbank_CP065934_HPG1.3-1OEM.800.1.0.20613240.vib","/CP065934_VMw.zip/metadata.zip/vendor-index.xml","/CP065934_VMw.zip/metadata.zip/vmware.xml","/CP065934_VMw.zip/metadata.zip/vibs/CP065934-3814721435429991454.xml","/CP065934_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065934_HPG1.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"4d5e9f6a15c48055215cc5bb33c07b5b","Name":"CP065934.zip","Release":"2025-03-07T06:33:27","Revision":"K","SHA1Sum":"ae4a522d8ed9bf8e0bbade4c1e50c1b8868ce67a","SHA256Sum":"e12b0c594afc4648294df325e6dede07d52755397a4108bf57b72f3f37c2c414","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065934","Version":"HPG1.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041520.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></p><p><br /><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></p><p><br /><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWKGR ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB006000GWKGR","TargetGUID":"4d2340a5-3042-3630-3030-3047574b4752","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:48:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8ac58cbcb5c54055b4aeda91c2755e86"}]},{"ProductId":"d6464fc039cd4a77b22febd8762dca03","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor and chipset."},{"Lang":"ja","Value":"This component installs driverless INFs to identify devices in the processor and chipset."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"626400","DateModified":"2025-11-17T06:35:13","FileList":["cp069695.xml","cpqsetup.exe","installer.dll","pnp/","pnp/cannonlake-h.cat","pnp/CannonLake-HSystem.inf","pnp/CannonLake-HSystemThermal.inf","pnp/coffeelake.cat","pnp/CoffeelakeSystem.inf","pnp/null_heci.cat","pnp/NULL_HECISystem.inf"],"MD5Sum":"e6659706df9395d1c2511932a3ae092e","Name":"cp069695.exe","Release":"2025-11-17T06:33:06","Revision":"B","SHA1Sum":"0a07bce4923e07390936610807e3115b6b867336","SHA256Sum":"2f04fe3466c2b504682f44d8cc3779f83e2446a15ad2f0007c63afe717f8930d","Size":"611KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19928.8615"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for Intel Xeon E-22xx Processor for Microsoft Windows"},{"Lang":"ja","Value":"Microsoft Windows用インテルXeon E-22xxプロセッサーの識別子"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-17T06:14:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li><li>Updated&nbsp;Supported Platforms</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li><li>サポートされるプラットフォームをアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li><li>Updated&nbsp;Supported Platforms</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19928.8615"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated setup utility dependencies</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19928.8615"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3fd3503e391649f990dc2557579bb78f"}]},{"ProductId":"c4ef0470aa934a20948f1a88d8eff26d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJNドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5315488","DateModified":"2025-09-21T20:27:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/CP068914.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/GPM1643ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068914.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068914.scexe"],"MD5Sum":"fb4af748d4a0dd3f5cf7b2af861f9424","Name":"firmware-hdd-35fd24601f-HPD5-6.1.x86_64.rpm","Release":"2025-09-22T01:16:33","Revision":"F","SHA1Sum":"80425a54b8fdc1dbce3eb24679ae762887f48dfd","SHA256Sum":"6a87432ff1cb3991599af9c9179cd9186b5f0e32b087f50fbe3d4eb1325790ee","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP043252.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJLおよびVO015360JWZJNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO015360JWZJN","TargetGUID":"562340a5-304f-3531-3336-304a575a4a4e","Type":"sas"},{"Id":"VO007680JWZJL","TargetGUID":"562340a5-304f-3730-3638-304a575a4a4c","Type":"sas"},{"Id":"VO003840JWZJK","TargetGUID":"562340a5-304f-3330-3834-304a575a4a4b","Type":"sas"},{"Id":"VO001920JWZJH","TargetGUID":"562340a5-304f-3130-3932-304a575a4a48","Type":"sas"},{"Id":"VO000960JWZJF","TargetGUID":"562340a5-304f-3030-3936-304a575a4a46","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:54:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li><li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"431afbfd2b4549a49c85282054fc0115"}]},{"ProductId":"10b8cebc40fb4b69b234ff81bd7e1d1f","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp068008.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2927384","DateModified":"2025-11-14T06:00:17","FileList":["cp068008.compsig","cp068008.zip","cp069636.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"a637b4fcf764763a92ba4df8f47cd301","Name":"cp069636.exe","Release":"2025-11-14T05:58:50","Revision":"B","SHA1Sum":"6ba0d42cd6de1a8c00afe827934bdcec05d28509","SHA256Sum":"6d393dfc53a55688ccbcaa4bf12768bce0471f87ccb92b3ea75fe717066483fc","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &nbsp;&lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &nbsp;&lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20 Gen10 Plus"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-12-14T05:53:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.708 (2.50_07_25_2025) は、システムROM 2.50 (08/06/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.3 guidance.This version of the SPS 06.00.03.708 (2.50_07_25_2025) should be paired with System ROM 2.50 (08/06/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.708"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5c9a9559677842a8bac1e869efe1f08d"}]},{"ProductId":"1ba6abb4e9ff40ab8c8d2a6c0f1a1860","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID® Gen11コントローラー製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2171970","DateModified":"2025-08-25T04:26:20","FileList":["./opt/MegaRAID/storcli/storcli64","./usr/share/smartupdate/storcli/component.xml"],"MD5Sum":"8fd5b7894a820591d4938e38d133309f","Name":"storcli_007.3212.0000.0000_all.deb","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"9a504f56ff0e1c045a3afec1b1134e394448279c","SHA256Sum":"2fa7eaa7c40ae2e04b4a075ed02141a3b643a6e38395d85967a6d2a90a6ff3d7","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"007.3212.0000.0000"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Description:<br />===========<br />This is a StorCLI readme file mentioning instructions to use:<br />&nbsp;&nbsp; &nbsp;1. StorCLI on all the supported operating systems.<br />&nbsp;&nbsp; &nbsp;2. StorCLI&#39;s JSON Schema files.<br />&nbsp;&nbsp; &nbsp;3. StorCLI&#39;s logging feature.</p><p>Please read before you start using StorCLI executable.</p><p>&nbsp;</p><p>Privileges:<br />=========<br />&nbsp;&nbsp; &nbsp;1. StorCLI should be installed / executed with administrative / root / super user privileges.<br />&nbsp;&nbsp; &nbsp;2. Installed/Execution location should have Read/Write/Execute permissions.</p><p>&nbsp;</p><p>Ubuntu:<br />=======<br />Installation:&nbsp;&nbsp; &nbsp;&nbsp;<br />&nbsp;&nbsp; &nbsp;1. Debian package can be installed using following command syntax : sudo dpkg -i &lt;.deb package&gt;<br />&nbsp;&nbsp; &nbsp;2. Installed debian package can be verified using following command syntax : dpkg -l | grep -i storcli</p><p>&nbsp;</p><p>Logging:<br />========&nbsp;<br />&nbsp;&nbsp; &nbsp;1. While executing StorCLI, Logging is enabled by default.<br />&nbsp;&nbsp; &nbsp;2. To Turn-off the logging, Place the storcliconf.ini in the current directory and change the DEBUGLEVEL to 0.<br />&nbsp;&nbsp; &nbsp;3. To change the log level, Place the storcliconf.ini in the current directory and change the DEBUGLEVEL to any desired log level.<br />&nbsp;&nbsp; &nbsp;4. In case of application crash, Place the storcliconf.ini in the current directory to capture logs.</p>"},{"Lang":"ja","Value":"<p>Description:<br />===========<br />これは、使用手順を記載したStorCLIのReadmeファイルです。<br />    1. StorCLIはすべてのサポートされているオペレーティングシステム上で利用可能です。<br />    2. StorCLI の JSON スキーマ ファイル。<br />    3. StorCLI のログ機能。</p><p>StorCLI 実行可能ファイルの使用を開始する前にお読みください。</p><p> </p><p>権限：<br />=========<br />    1. StorCLI は、管理者 / ルート / スーパーユーザー権限でインストール / 実行する必要があります。<br />    2. インストール/実行場所には読み取り/書き込み/実行権限が必要です。</p><p> </p><p>Ubuntu:<br />=======<br />インストール：     <br />    1. Debianパッケージは次のコマンド構文を使用してインストールできます: sudo dpkg -i <.deb パッケージ><br />    2. インストールされた Debian パッケージは、次のコマンド構文を使用して確認できます: dpkg -l | grep -i storcli</p><p> </p><p>ログ：<br />======== <br />    1. StorCLIの実行中、ログ記録はデフォルトで有効になります。<br />    2. ログ記録をオフにするには、storcliconf.iniを現在のディレクトリに配置し、DEBUGLEVELを0に変更します。<br />    3. ログレベルを変更するには、storcliconf.iniを現在のディレクトリに配置し、DEBUGLEVELを任意のログレベルに変更してください。<br />    4. アプリケーションがクラッシュした場合、ログをキャプチャーするために storcliconf.ini を現在のディレクトリに配置します。</p>"},{"Lang":"cn","Value":"<p>Description:<br />===========<br />This is a StorCLI readme file mentioning instructions to use:<br />&nbsp;&nbsp; &nbsp;1. StorCLI on all the supported operating systems.<br />&nbsp;&nbsp; &nbsp;2. StorCLI&#39;s JSON Schema files.<br />&nbsp;&nbsp; &nbsp;3. StorCLI&#39;s logging feature.</p><p>Please read before you start using StorCLI executable.</p><p>&nbsp;</p><p>Privileges:<br />=========<br />&nbsp;&nbsp; &nbsp;1. StorCLI should be installed / executed with administrative / root / super user privileges.<br />&nbsp;&nbsp; &nbsp;2. Installed/Execution location should have Read/Write/Execute permissions.</p><p>&nbsp;</p><p>Ubuntu:<br />=======<br />Installation:&nbsp;&nbsp; &nbsp;&nbsp;<br />&nbsp;&nbsp; &nbsp;1. Debian package can be installed using following command syntax : sudo dpkg -i &lt;.deb package&gt;<br />&nbsp;&nbsp; &nbsp;2. Installed debian package can be verified using following command syntax : dpkg -l | grep -i storcli</p><p>&nbsp;</p><p>Logging:<br />========&nbsp;<br />&nbsp;&nbsp; &nbsp;1. While executing StorCLI, Logging is enabled by default.<br />&nbsp;&nbsp; &nbsp;2. To Turn-off the logging, Place the storcliconf.ini in the current directory and change the DEBUGLEVEL to 0.<br />&nbsp;&nbsp; &nbsp;3. To change the log level, Place the storcliconf.ini in the current directory and change the DEBUGLEVEL to any desired log level.<br />&nbsp;&nbsp; &nbsp;4. In case of application crash, Place the storcliconf.ini in the current directory to capture logs.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator StorCLI for Ubuntu (for Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator StorCLI for Ubuntu (for Gen10PおよびGen11コントローラー)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator StorCLI for Ubuntu (for Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-22T04:17:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加<ul><li>コマンド: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"cn"}],"Version":"007.3212.0000.0000"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加<ul><li>コマンド: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Add support for users to clear NVRAM using Factory Repurpose operation<ul><li>Command: storcli /cx set factory repurpose</li></ul></li></ul>","Fixes":"","Lang":"cn"}],"Version":"007.3212.0000.0000"}],"SWKeys":[{"Name":"storcli","SWKeyExpectedPath":"software:deb"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ea314d781ac146b79f767639545d4066"}]},{"ProductId":"3178a35014a54eb187ac32bf0e1852e0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."},{"Lang":"ja","Value":"セキュアブートモードでのHPE Mellanox MFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"31340738","DateModified":"2025-10-07T14:56:45","FileList":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/09","./usr/lib/.build-id/09/f109281b8e907068ffd7c1c342858dff784e01","./usr/lib/.build-id/0f","./usr/lib/.build-id/0f/06c107262adada878deb0f9fa83d774f751f48","./usr/lib/.build-id/10","./usr/lib/.build-id/10/0a8c0576f6803c90885f113b58394a44f0a871","./usr/lib/.build-id/10/c7a8c5696bd094204a596bce50b1ba1fb846cb","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/1db7f49eaa674db0f2554468466f00011e0172","./usr/lib/.build-id/2d","./usr/lib/.build-id/2d/758b0ad35a7f5767e77fd249b875d632a45733","./usr/lib/.build-id/39","./usr/lib/.build-id/39/8a0d4dd55e47ce4f6d070acecfdb122289d33f","./usr/lib/.build-id/42","./usr/lib/.build-id/42/aaea6007932f09a5c3309dbc5a5ccc072cf035","./usr/lib/.build-id/48","./usr/lib/.build-id/48/dedbe624bd18afdad53e7f49e678733023b908","./usr/lib/.build-id/4c","./usr/lib/.build-id/4c/35559fa839acc99a9c75a3dc8422b24cf1bda7","./usr/lib/.build-id/51","./usr/lib/.build-id/51/39ebac45d29b13d9165f1f74cda6ff3da41cde","./usr/lib/.build-id/5d","./usr/lib/.build-id/5d/bbdf0b0c073e7be1d04a3e0e647fddddf686e2","./usr/lib/.build-id/60","./usr/lib/.build-id/60/bfe2319a1267622d58682d4f739da72567e8f8","./usr/lib/.build-id/63","./usr/lib/.build-id/63/0048b7ed76eec96328ace78f9397670dfbf39d","./usr/lib/.build-id/64","./usr/lib/.build-id/64/70e23454c94c00d458d330decb11f4bfada781","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/9765d63e6ec7eff0b34d9355ed62c54238c03a","./usr/lib/.build-id/74","./usr/lib/.build-id/74/2fa7fe1af4bc2e5546226ffb413385abe30056","./usr/lib/.build-id/76","./usr/lib/.build-id/76/cddc0af7cf963769c8ae730fd3443ff95fe869","./usr/lib/.build-id/81","./usr/lib/.build-id/81/0aff60310d4da78fcf604ce98bf4d0bb82983b","./usr/lib/.build-id/82","./usr/lib/.build-id/82/c932a3195593bd1f6ff6c462cc7aebe3c64add","./usr/lib/.build-id/85","./usr/lib/.build-id/85/e0ca034196c107f7a88b23cd7af942d9eb2d40","./usr/lib/.build-id/8b","./usr/lib/.build-id/8b/36d15bed3b078dd01aae8ed23fef0552ebdcc3","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/0f00edeff5dd8f8daf3f6d054cac5b30775ada","./usr/lib/.build-id/91","./usr/lib/.build-id/91/34aa2fbe03361af16f037094235b54e2957851","./usr/lib/.build-id/93","./usr/lib/.build-id/93/e20b792c9e9e6b18557e3b4d5741b0f54e8044","./usr/lib/.build-id/ac","./usr/lib/.build-id/ac/30394f6339d378871506935512a61504b6c304","./usr/lib/.build-id/b4","./usr/lib/.build-id/b4/51faf1296981ec859e8d515c8ff9644bfc64ec","./usr/lib/.build-id/b5","./usr/lib/.build-id/b5/0e1c1d7671fc03dcc87f74b4d41893efcadf54","./usr/lib/.build-id/b7","./usr/lib/.build-id/b7/82443d6962db647257a8fb8879cf28fbad0c93","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/3bdd4b85f6928930b1030cba40cee60458d945","./usr/lib/.build-id/bf/5eec04e20f7ffc87fc5b4375658c981df3ac11","./usr/lib/.build-id/c1","./usr/lib/.build-id/c1/326615a196bad2ef9cf7906a82fb301ac3ffd1","./usr/lib/.build-id/c3","./usr/lib/.build-id/c3/af518fbf4f31021d87d31824acaeaf981a4d86","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/d7af687801a418c6cafd69c3d986659039589d","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/840cae88a2719081ace2774afbe4a39a9ff08d","./usr/lib/.build-id/f1","./usr/lib/.build-id/f1/81098d4fef21db82f53346f2045097b4ec8b34","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/cbdaeee8cd3ad8284fdd44f0af6317f466e9de","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/876e7ad783090ff0db05fe68e6ffdbec0348c0","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/ext_libs/libcrypto.so.3","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/gpu_drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/device_info","./usr/share/mft/device_info/json","./usr/share/mft/device_info/json/0x11.json","./usr/share/mft/device_info/json/0x19.json","./usr/share/mft/device_info/json/0x1e.json","./usr/share/mft/device_info/json/0x1f5.json","./usr/share/mft/device_info/json/0x1f7.json","./usr/share/mft/device_info/json/0x1ff.json","./usr/share/mft/device_info/json/0x209.json","./usr/share/mft/device_info/json/0x20b.json","./usr/share/mft/device_info/json/0x20d.json","./usr/share/mft/device_info/json/0x20f.json","./usr/share/mft/device_info/json/0x211.json","./usr/share/mft/device_info/json/0x212.json","./usr/share/mft/device_info/json/0x214.json","./usr/share/mft/device_info/json/0x216.json","./usr/share/mft/device_info/json/0x218.json","./usr/share/mft/device_info/json/0x21c.json","./usr/share/mft/device_info/json/0x21e.json","./usr/share/mft/device_info/json/0x220.json","./usr/share/mft/device_info/json/0x222.json","./usr/share/mft/device_info/json/0x224.json","./usr/share/mft/device_info/json/0x226.json","./usr/share/mft/device_info/json/0x247.json","./usr/share/mft/device_info/json/0x249.json","./usr/share/mft/device_info/json/0x24b.json","./usr/share/mft/device_info/json/0x24d.json","./usr/share/mft/device_info/json/0x24e.json","./usr/share/mft/device_info/json/0x250.json","./usr/share/mft/device_info/json/0x252.json","./usr/share/mft/device_info/json/0x253.json","./usr/share/mft/device_info/json/0x254.json","./usr/share/mft/device_info/json/0x256.json","./usr/share/mft/device_info/json/0x257.json","./usr/share/mft/device_info/json/0x259.json","./usr/share/mft/device_info/json/0x25b.json","./usr/share/mft/device_info/json/0x270.json","./usr/share/mft/device_info/json/0x274.json","./usr/share/mft/device_info/json/0x278.json","./usr/share/mft/device_info/json/0x27c.json","./usr/share/mft/device_info/json/0x282.json","./usr/share/mft/device_info/json/0x288.json","./usr/share/mft/device_info/json/0x2900.json","./usr/share/mft/device_info/json/0x3.json","./usr/share/mft/device_info/json/0x3000.json","./usr/share/mft/device_info/json/0x3480.json","./usr/share/mft/device_info/json/0x6b.json","./usr/share/mft/device_info/json/0x6e.json","./usr/share/mft/device_info/json/0x6f.json","./usr/share/mft/device_info/json/0x70.json","./usr/share/mft/device_info/json/0x71.json","./usr/share/mft/device_info/json/0x72.json","./usr/share/mft/device_info/json/0x73.json","./usr/share/mft/device_info/json/0x7e.json","./usr/share/mft/device_info/json/0x7f.json","./usr/share/mft/device_info/json/0x80.json","./usr/share/mft/device_info/json/0x82.json","./usr/share/mft/device_info/json/0x84.json","./usr/share/mft/device_info/json/0xd.json","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/gpu","./usr/share/mft/prm_dbs/gpu/ext","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers","./usr/share/mft/prm_dbs/retimers/ext","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"MD5Sum":"c177ff1bf09de5feef39f979b8e49a60","Name":"mft-4.33.0-169.sles15sp7.x86_64.rpm","Release":"2025-10-07T14:49:04","Revision":"","SHA1Sum":"c1fe74ad4f1e167abb716c32359cd3913ba6b810","SHA256Sum":"b5f4608e486a291e47d47fed1f8314dfe86f91d44ad6a48c81e3fb52e1bb1afc","Size":"29MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"TypeOfChange":"0","Version":"4.33.0-169"},{"Bytes":"77217","DateModified":"2025-10-07T15:01:53","FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/mst_pci.ko","./lib/modules/6.4.0-150700.51-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"MD5Sum":"eda01ef60cfd321dbb064a110e4d9bfa","Name":"kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-10-07T14:49:04","Revision":"","SHA1Sum":"d001a00ab92df0d89ec0d07567792dc847b04b56","SHA256Sum":"3ad0a868945de03c5e2eb5a27bd2f4d8c0777df455279249a9050889c1ea7420","Size":"75KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"TypeOfChange":"0","Version":"4.33.0-169"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.</p><p>To install or upgrade the driver:<br /><br />If using 6.4.0_150700.48-default kernel or any future errata:</p><p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150700.48-1.sles15sp7.x86_64.rpm&nbsp;mft-4.33.0-169.sles15sp7.x86_64.rpm</strong></p><p>Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.</p><p>To install or upgrade the driver:<br /><br />If using 6.4.0_150700.48-default kernel or any future errata:</p><p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150700.48-1.sles15sp7.x86_64.rpm&nbsp;mft-4.33.0-169.sles15sp7.x86_64.rpm</strong></p><p>Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.</p><p>To install or upgrade the driver:<br /><br />If using 6.4.0_150700.48-default kernel or any future errata:</p><p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.33.0_k6.4.0_150700.48-1.sles15sp7.x86_64.rpm&nbsp;mft-4.33.0-169.sles15sp7.x86_64.rpm</strong></p><p>Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP7 (AMD64/EM64T)"},{"Lang":"ja","Value":"SUSE Linux Enterprise Server 15 SP7 (AMD64/EM64T)のセキュアブートモードでのMellanoxアダプターのファームウェアアップデート用のHPE Mellanox MFT前提条件RPM"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP7 (AMD64/EM64T)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-11-07T12:13:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.32.0-120"},{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.33.0-169"}],"SWKeys":[{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c96c133d9d3d48b3abe4b05698877151"}]},{"ProductId":"83ce77cbc6db45d29c95de38716f222e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"}],"Files":[{"Bytes":"4634480","DateModified":"2025-11-15T17:18:13","FileList":["cp068748.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEBsssASFD4.rel"],"MD5Sum":"ff94e22cac994a225a1f37fbbe16600d","Name":"cp068748.exe","Release":"2025-11-15T17:12:52","Revision":"D","SHA1Sum":"e23e814d9ce520c4e56d5ce5053f8652b366094e","SHA256Sum":"f3ece865a1af1c77d8571eaf8629954effa0bed8fcc26463849a85e4cba56f7d","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWUDB ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000JWUDB","TargetGUID":"4d2340a5-3042-3431-3030-304a57554442","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T08:26:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e33b47e3812f43beab0d6c1014b6cbcf"}]},{"ProductId":"a905a1ce40514e0aba7f765d4f2557ae","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000GZYVT、MB014000GZYVU、MB016000GZYVV、MB018000GYCLL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improves data integrity.&nbsp;</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide a minor performance improvement.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improves data integrity.&nbsp;</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide a minor performance improvement.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5991011","DateModified":"2025-09-17T12:25:03","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1/CP068868.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1/TAMG09acHPG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068868.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068868.scexe"],"MD5Sum":"84c4c580faadc04b314e22b1566fdfec","Name":"firmware-hdd-e0171a2936-HPG4-5.1.x86_64.rpm","Release":"2025-09-17T17:15:05","Revision":"E","SHA1Sum":"375622a7a035f0202a52ca686c22201da24a07fb","SHA256Sum":"e66b90b727188e447764a392af03181826e34e8b33d6e5d7c82f41e54ec4275c","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"CP042460.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000GZYVT、MB014000GZYVU、MB016000GZYVV、およびMB018000GYCLLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB012000GZYVT","TargetGUID":"4d2340a5-3042-3231-3030-30475a595654","Type":"sata"},{"Id":"MB014000GZYVU","TargetGUID":"4d2340a5-3042-3431-3030-30475a595655","Type":"sata"},{"Id":"MB016000GZYVV","TargetGUID":"4d2340a5-3042-3631-3030-30475a595656","Type":"sata"},{"Id":"MB018000GYCLL","TargetGUID":"4d2340a5-3042-3831-3030-304759434c4c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T20:18:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e4f96604ef9a4309ade87be7cfdcccea"}]},{"ProductId":"0fb6a42a8b224caba8a145e0ac696d52","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.62 (01/09/2026)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.62_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.62 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12011820","DateModified":"2026-01-14T02:39:08","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.62_2026_01_09-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.62_2026_01_09-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.62_2026_01_09-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.62_2026_01_09-1.1/CP070356.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.62_2026_01_09-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.62_2026_01_09-1.1/U34_3.62_01_09_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.62_2026_01_09-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.62_2026_01_09-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.62_2026_01_09-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070356.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070356.scexe"],"MD5Sum":"6618fc0ba1ddb99a15da443133785029","Name":"firmware-system-u34-3.62_2026_01_09-1.1.x86_64.rpm","Release":"2026-01-14T08:29:52","Revision":"","SHA1Sum":"c23be1794da943578a5cbffb3e85feef7502d553","SHA256Sum":"b7524888a4086acabd45c80312e492a01c374e70f9ce30a03a6ceedcdd6fee7f","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.62_01-09-2026"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上に見られるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10（U34）サーバー "},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-13T03:41:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel Purley IPU2025.3アップデートに合わせたアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.201と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムROMのアップデート中にシステムRBSU設定の変更が有効にならない場合がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Purley IPU2025.3 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system RBSU setting change might not take effect when the System ROM is being updated.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_08-06-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added a new RBSU service option for supporting MMCFG base at 1.5GB</p><p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.201.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.62_01-09-2026"}],"SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9970de07e95b44ed9c3fefbecab84af0"}]},{"ProductId":"8484f11834644aea8a2a14d1d0d58403","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for the Marvell FastLinQ 10/25/50 GbE Drivers for Microsoft Windows Server 2022 and Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Marvell FastLinQ 10/25/50 GbEドライバーfor Microsoft Windows Server 2022およびMicrosoft Windows Server 2025を含みます。"},{"Lang":"cn","Value":"This Component Package contains the drivers for the Marvell FastLinQ 10/25/50 GbE Drivers for Microsoft Windows Server 2022 and Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This component contains the following drivers:</p><ul><li>Windows qevbd Driver is 8.72.21.0</li><li>Windows qend Driver is 8.72.21.0</li><li>Windows qefcoe Driver is 8.70.3.0</li><li>Windows qxdiag Driver is 8.14.0.0</li><li>Windows qeois Driver is 8.70.2.0</li></ul>"},{"Lang":"ja","Value":"<p>このコンポーネントは、以下のドライバーを含みます。</p><ul><li>Windows qevbdドライバーは8.72.21.0です</li><li>Windows qendドライバーは8.72.21.0です</li><li>Windows qefcoeドライバーは8.70.3.0です</li><li>Windows qxdiagドライバーは8.14.0.0です</li><li>Windows qeoisドライバーは8.70.2.0です</li></ul>"},{"Lang":"cn","Value":"<p>This component contains the following drivers:</p><ul><li>Windows qevbd Driver is 8.72.21.0</li><li>Windows qend Driver is 8.72.21.0</li><li>Windows qefcoe Driver is 8.70.3.0</li><li>Windows qxdiag Driver is 8.14.0.0</li><li>Windows qeois Driver is 8.70.2.0</li></ul>"}],"Files":[{"Bytes":"6506648","DateModified":"2025-11-14T04:41:18","FileList":["cp069563.xml","cpqsetup.exe","cp_data.xml","DrvFil~1.cab","install.xml","multisetup.dll","QDrv4500.msi"],"MD5Sum":"8ae5a2270f4908f340dbd4b49883b7b2","Name":"cp069563.exe","Release":"2025-11-14T04:28:04","Revision":"C","SHA1Sum":"dcf43014910c8289908a0f93836dc0c899daf820","SHA256Sum":"5b2a9b056422849549fc7dd49cc6e20c0b6412af461767e728eac623c6f3f84c","Size":"6MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"TypeOfChange":"1","Version":"8.72.21.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Marvell FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"Lang":"ja","Value":"Marvell FastLinQ 10/25/50 GbEドライバー for Windows Server x64 Edition"},{"Lang":"cn","Value":"Marvell FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770070","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770069","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770068","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770071","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770072","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770074","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770073","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T09:16:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Add Windows Server 2025 support.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Windows Server 2025のサポートを追加</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Add Windows Server 2025 support.</p>","Fixes":"","Lang":"cn"}],"Version":"8.72.21.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Local 24H2 をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Local 24H2.</p>","Fixes":"","Lang":"cn"}],"Version":"8.72.21.0"}],"SWKeys":[{"Name":"qevbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1e029bdb27234af1b25a757bd92ea0a5"}]},{"ProductId":"ae6b2b73e1ee45bc9e25c451f9dd6d2f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB012000GZYVT、MB014000GZYVU、MB016000GZYVV、MB018000GYCLL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Local 24H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4145800","DateModified":"2025-11-14T11:25:14","FileList":["cp068766.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG09acHPG4.rel"],"MD5Sum":"1d819499accd91acd61ccf9147cedaad","Name":"cp068766.exe","Release":"2025-11-14T11:20:38","Revision":"D","SHA1Sum":"23b8c8a5bb268e02486271809a6aa7d0c3f3c056","SHA256Sum":"bf1bf721801e691766e565329a73698f91996ccf453c38febaa01771016fa1e7","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVVおよびMB018000GYCLL ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB012000GZYVT","TargetGUID":"4d2340a5-3042-3231-3030-30475a595654","Type":"sata"},{"Id":"MB014000GZYVU","TargetGUID":"4d2340a5-3042-3431-3030-30475a595655","Type":"sata"},{"Id":"MB016000GZYVV","TargetGUID":"4d2340a5-3042-3631-3030-30475a595656","Type":"sata"},{"Id":"MB018000GYCLL","TargetGUID":"4d2340a5-3042-3831-3030-304759434c4c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-10T09:48:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0fce20322b36427496f326ea294a9d42"}]},{"ProductId":"ae57ff279aab4e628b9d7923b0985d81","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSSD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3432-3030-304a59455645","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model: MB24000JYEVE"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB24000JYEVE"},{"Lang":"cn","Value":"This package provides firmware for the following drive model: MB24000JYEVE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Enhancements/New Features:</strong></p><ul><li>RPM data missing from iLO GUI</li></ul><p><strong>Problems Fixed:</strong></p><ul><li><p>Regular FW fix on assert, time-out, error log several fixes</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Enhancements/New Features:</strong></p><ul><li>RPM data missing from iLO GUI</li></ul><p><strong>Problems Fixed:</strong></p><ul><li><p>Regular FW fix on assert, time-out, error log several fixes</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1</p><p><strong>Enhancements/New Features:</strong></p><ul><li>RPM data missing from iLO GUI</li></ul><p><strong>Problems Fixed:</strong></p><ul><li><p>Regular FW fix on assert, time-out, error log several fixes</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3767413","DateModified":"2025-11-27T11:57:16","FileList":["payload.json","Seagate_Summit_SUMMITSUSSD3.HPb","Seagate_Summit_SUMMITSUSSD3.xml"],"MD5Sum":"d13b2b4581b9d5f8c79996d60d80fb8d","Name":"Seagate_Summit_SUMMITSUSSD3.fwpkg","Release":"2025-11-27T11:54:47","Revision":"B","SHA1Sum":"78ccea21d0e3d89d7de5138d3e62155cf39cb078","SHA256Sum":"b757e443c9fd1481c37b651d9e4a08ebfcd60ae7cf9f5de03ebdafa9c0863913","Size":"3MB","TargetGUIDs":["002340a5-424d-3432-3030-304a59455645"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB24000JYEVE"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MB24000JYEVE"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB24000JYEVE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB24000JYEVE","TargetGUID":"002340a5-424d-3432-3030-304a59455645","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-27T11:08:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>RPM data missing from iLO GUI</li></ul>","Fixes":"<ul><li>Regular FW fix on assert, time-out, error log several fixes</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>RPM data missing from iLO GUI</li></ul>","Fixes":"<ul><li>Regular FW fix on assert, time-out, error log several fixes</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>RPM data missing from iLO GUI</li></ul>","Fixes":"<ul><li>Regular FW fix on assert, time-out, error log several fixes</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB24000JYEVE","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"54c9602889d54d00bfe7cae757318823"}]},{"ProductId":"b8b6b31789ce4119a48876ba4b89c81f","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.72 (01/09/2026)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.72_01_09_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.72 (01/09/2026)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16816193","DateModified":"2026-01-13T06:08:56","FileList":["payload.json","U48_3.72_01_09_2026.signed.flash","U48_3.72_01_09_2026.xml"],"MD5Sum":"d1d44aba446bb3454678c164aae594ae","Name":"U48_3.72_01_09_2026.fwpkg","Release":"2026-01-13T06:05:43","Revision":"","SHA1Sum":"30bad286a2b384f3bd70b363493d35bf9904064f","SHA256Sum":"5462e25bdfe542409569ebbd2f7377fa6a2cd41dde823523c10f2f22768dd8df","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"TypeOfChange":"1","Version":"3.72_01-09-2026"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - MicroServer Gen10 Plus (U48) サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-12T03:46:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、インテル製品アップデート（IPU）バージョンIPU.2025.3ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.103と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU 2025.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.3 guidance.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.70_08-08-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated the warning message wording of \"Intelligent Provisioning\" for OEM.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.103.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO Remote Console could become unresponsive when a warning message appeared in RBSU.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_01-09-2026"}],"SWKeys":[{"Name":"U48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"41a82d4d432c4b47a326bc31742d93ca"}]},{"ProductId":"87a7eb56c25b4c4c98ceb5ea24664524","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR216i-p_Gen10P_52.32.3-6333_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.32.3-6333"}]},"MinimumActiveVersion":"52.26.3.5487","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"HPE MR216i-p Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE MR216i-p Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"ja","Value":"<p>One-buttonセキュア消去（OBSE）およびオンラインファームウェアアクティベーション（OFA）はHPE Gen10サーバーではサポートされていないため、MR Gen10 plusコントローラーはGen10サーバーでのオンラインファームウェアアップデートをサポートしません。<br />HPE Gen10サーバーにFWPKGをインストールする必要がある場合は、FWPKGをフラッシュした後に再起動が必要になることを想定してください。</p>"},{"Lang":"cn","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"}],"Files":[{"Bytes":"7514222","DateModified":"2025-08-19T12:47:12","FileList":["HPE_MR216i-p_Gen10P_52.32.3-6333_A.HPb","HPE_MR216i-p_Gen10P_52.32.3-6333_A.xml","payload.json"],"MD5Sum":"805bf9e2821b4cb495fec5c1f18afbcf","Name":"HPE_MR216i-p_Gen10P_52.32.3-6333_A.fwpkg","Release":"2025-09-04T00:00:00","Revision":"","SHA1Sum":"4f3c0d053f8501fae8b913e7d8c5cd7efa36bc01","SHA256Sum":"5532ba954959cb316a3b84976db0b54949e3fa3fbd305c0da9ef5ed665dcff9f","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032b"],"TypeOfChange":"1","Version":"52.32.3-6333"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/connect/s/product?language=en_US&kmpmoid=7630408&tab=driversAndSoftware&driversAndSoftwareFilter=8000078\">RESTfulインターフェイスツール</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p><p>iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li></ul>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE MR216i-p Gen10 Plus Tri Mode Controller "},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE MR216i-p Gen10 Plusトライモードコントローラー "},{"Lang":"cn","Value":"Firmware Package - HPE MR216i-p Gen10 Plus Tri Mode Controller "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T18:02:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfish デバイス有効化の機能強化<ul><li>Redfishボリューム変換サポート<ul><li>POST #Volume.ChangeRAIDLayout: RAIDレイアウトの変更。RAIDレイアウトの変更は、入力JSONボディにターゲットRAIDTypeとドライブのリストを提供することで実現されます。</li><li>POST #Volume.ChangeRAIDLayout: サイズ変更。ChangeRAIDLayoutを使用すると、RAIDTypeを変更せずに新しい未構成正常ドライブを追加することでボリュームのサイズを変更できます。このような場合、入力JSONボディでRAIDTypeを指定してはいけませんが、それに応じて完全なドライブリストを指定する必要があります。</li><li>PATCH Volume[CapacityBytes]: この操作は、ボリューム内に利用可能な未使用サイズがある場合にボリュームのサイズを変更するために使用されます。ここに新しいドライブを追加するスコープはありません</li><li>POST #Volume.CheckConsistency: この操作は、ボリューム上の整合性チェック操作を開始します。この操作では入力は想定されません。</li></ul></li><li>Redfish Metrics GETサポート<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount、CorrectableECCErrorCount、CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount、SAS.LossOfDwordSynchronizationCount、SAS.RunningDisparityErrorCount、PCIeErrors.CorrectableErrorCount、PCIeErrors.FatalErrorCount、PCIeErrors.NonFatalErrorCount</li><li>各カウンターは最大65535までの値を保持できます。カウンターが最大値に達しても、値はリセットされません。</li><li>ユーザーがコントローラーのNVRAMクリアまたはRedfish ResetToDefaults.ResetAllを実行すると、メトリックはクリアされます。</li></ul></li></ul></li><li>MRSAおよびstorcli工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加。<ul><li>コントローラー上に構成が存在する場合、または固定キャッシュが存在する場合、NVRAMクリア操作は許可されません。</li><li>NVRAMをクリアした後、コントローラーFWはオンラインコントローラーリセット (OCR) を実行します。何らかの理由でOCRを実行できない場合は、システムを再起動するようにユーザーに通知されます。</li><li>NVRAMクリア操作は、機能的にはRedfish ResetToDefaults.ResetAll操作と同等です。</li></ul></li><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。非ホットプラグ構成の場合、コントローラーは常に16個のベイを表示します。</li></ul>","Fixes":"<ul><li>a00143124en_usアドバイザリを修正: HPE MR Gen11 コントローラー - HPE Gen11サーバー上のMR Gen11コントローラーがIMLで\"WriteCacheDataLoss\"を生成できない場合がある</li><li>a00148035en_usアドバイザリを修正: HPE MR Gen11コントローラー - ベイとボックスのNVMeドライブの場所がワンタイムブートメニューに表示されない</li><li>Linux OSでLTOの128KBを超える読み取り/書き込み転送が失敗する問題を修正</li><li>Backup ExecがLTOで動作しない問題を修正</li><li>240個の論理ドライブが構成されている場合、サーバーのブート時にコントローラーがiLOによってドロップされる可能性がある問題を修正</li><li>ドライブを連続的に削除すると、サーバーヘルスが一時的にクリティカルを示すというまれな問題を修正</li><li>予期しないPCIConfiglinkページイベント、仮想SESデバイスへのタスク管理のタイムアウトメッセージがsnapdumpに記録される問題を修正</li><li>空のベイにスロット対応プロトコルがない問題を修正</li><li>コントローラーに接続されたLTOのリンク速度が[不明]と表示される問題を修正</li><li>Request Senseコマンドにより、サニタイズが進行中のドライブでタスク管理が実行される問題を修正。</li><li>255を超える値が使用された場合に、Redfish PATCH StorageController[ControllerRates]がランダムな値を暗黙的に設定してしまう問題を修正。</li><li>コントローラーがパススルーとして構成されているときにVMを再起動すると、誤ったコントローラーエラーイベントが記録される可能性がある問題を修正</li><li>2つのバックプレーンが同じストレージポートに接続されている場合、Redfishファブリックポートのアクティブ幅と現在の速度が間違っているという問題を修正。</li><li>再起動後にNVMeドライブのリンクステータスが失敗する可能性があるというまれな問題を修正 </li><li>複数のドライブの取り外しと挿入が短時間に行われたときにコントローラーがアサートされる可能性があるというまれな問題を修正</li><li>SATAパススルーコマンドが実行中の場合、SATAドライブのサニタイズのパーセンテージが進行しない問題を修正</li><li>NVMeドライブでサニタイズのパーセンテージが進行しない問題を修正</li><li>読み取り/書き込みコマンドと非読み取り/書き込みコマンドの耐久テストでIOタイムアウトとデバイスリセットが発生することがあるというまれな問題を修正</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"cn"}],"Version":"52.32.3-6333"},{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfish デバイス有効化の機能強化<ul><li>Redfishボリューム変換サポート<ul><li>POST #Volume.ChangeRAIDLayout: RAIDレイアウトの変更。RAIDレイアウトの変更は、入力JSONボディにターゲットRAIDTypeとドライブのリストを提供することで実現されます。</li><li>POST #Volume.ChangeRAIDLayout: サイズ変更。ChangeRAIDLayoutを使用すると、RAIDTypeを変更せずに新しい未構成正常ドライブを追加することでボリュームのサイズを変更できます。このような場合、入力JSONボディでRAIDTypeを指定してはいけませんが、それに応じて完全なドライブリストを指定する必要があります。</li><li>PATCH Volume[CapacityBytes]: この操作は、ボリューム内に利用可能な未使用サイズがある場合にボリュームのサイズを変更するために使用されます。ここに新しいドライブを追加するスコープはありません</li><li>POST #Volume.CheckConsistency: この操作は、ボリューム上の整合性チェック操作を開始します。この操作では入力は想定されません。</li></ul></li><li>Redfish Metrics GETサポート<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount、CorrectableECCErrorCount、CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount、SAS.LossOfDwordSynchronizationCount、SAS.RunningDisparityErrorCount、PCIeErrors.CorrectableErrorCount、PCIeErrors.FatalErrorCount、PCIeErrors.NonFatalErrorCount</li><li>各カウンターは最大65535までの値を保持できます。カウンターが最大値に達しても、値はリセットされません。</li><li>ユーザーがコントローラーのNVRAMクリアまたはRedfish ResetToDefaults.ResetAllを実行すると、メトリックはクリアされます。</li></ul></li></ul></li><li>MRSAおよびstorcli工場再目的化操作を使用してユーザーがNVRAMをクリアするためのサポートを追加。<ul><li>コントローラー上に構成が存在する場合、または固定キャッシュが存在する場合、NVRAMクリア操作は許可されません。</li><li>NVRAMをクリアした後、コントローラーFWはオンラインコントローラーリセット (OCR) を実行します。何らかの理由でOCRを実行できない場合は、システムを再起動するようにユーザーに通知されます。</li><li>NVRAMクリア操作は、機能的にはRedfish ResetToDefaults.ResetAll操作と同等です。</li></ul></li><li>バックプレーンベイ数情報を、コントローラーに接続されている実際のベイに変更。非ホットプラグ構成の場合、コントローラーは常に16個のベイを表示します。</li></ul>","Fixes":"<ul><li>a00143124en_usアドバイザリを修正: HPE MR Gen11 コントローラー - HPE Gen11サーバー上のMR Gen11コントローラーがIMLで\"WriteCacheDataLoss\"を生成できない場合がある</li><li>a00148035en_usアドバイザリを修正: HPE MR Gen11コントローラー - ベイとボックスのNVMeドライブの場所がワンタイムブートメニューに表示されない</li><li>Linux OSでLTOの128KBを超える読み取り/書き込み転送が失敗する問題を修正</li><li>Backup ExecがLTOで動作しない問題を修正</li><li>240個の論理ドライブが構成されている場合、サーバーのブート時にコントローラーがiLOによってドロップされる可能性がある問題を修正</li><li>ドライブを連続的に削除すると、サーバーヘルスが一時的にクリティカルを示すというまれな問題を修正</li><li>予期しないPCIConfiglinkページイベント、仮想SESデバイスへのタスク管理のタイムアウトメッセージがsnapdumpに記録される問題を修正</li><li>空のベイにスロット対応プロトコルがない問題を修正</li><li>コントローラーに接続されたLTOのリンク速度が[不明]と表示される問題を修正</li><li>Request Senseコマンドにより、サニタイズが進行中のドライブでタスク管理が実行される問題を修正。</li><li>255を超える値が使用された場合に、Redfish PATCH StorageController[ControllerRates]がランダムな値を暗黙的に設定してしまう問題を修正。</li><li>コントローラーがパススルーとして構成されているときにVMを再起動すると、誤ったコントローラーエラーイベントが記録される可能性がある問題を修正</li><li>2つのバックプレーンが同じストレージポートに接続されている場合、Redfishファブリックポートのアクティブ幅と現在の速度が間違っているという問題を修正。</li><li>再起動後にNVMeドライブのリンクステータスが失敗する可能性があるというまれな問題を修正 </li><li>複数のドライブの取り外しと挿入が短時間に行われたときにコントローラーがアサートされる可能性があるというまれな問題を修正</li><li>SATAパススルーコマンドが実行中の場合、SATAドライブのサニタイズのパーセンテージが進行しない問題を修正</li><li>NVMeドライブでサニタイズのパーセンテージが進行しない問題を修正</li><li>読み取り/書き込みコマンドと非読み取り/書き込みコマンドの耐久テストでIOタイムアウトとデバイスリセットが発生することがあるというまれな問題を修正</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements<ul><li>Redfish Volume Transformation Support<ul><li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li><li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li><li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li><li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li></ul></li><li>Redfish Metrics GET Support<ul><li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li><li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li><li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li><li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li></ul></li></ul></li><li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.<ul><li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li><li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li><li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li></ul></li><li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li></ul>","Fixes":"<ul><li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li><li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li><li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li><li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li><li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li><li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li><li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li><li>Fix an issue that Slot capable protocol is missing for empty bay</li><li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li><li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li><li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li><li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li><li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li><li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li><li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li><li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li><li>Fix an issue that sanitize percentage does not progress on NVMe drives</li><li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li></ul>","Lang":"cn"}],"Version":"52.32.3-6333"}],"SWKeys":[{"Name":"032B1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"fa3158ccef374a59b773a2e5bc75aec7"}]},{"ProductId":"38437d438933420e8063d6e963ffd91f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM2000GEFRA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM2000GEFRA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5748764","DateModified":"2025-09-21T22:25:42","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1/CP068932.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1/SAVGRTG9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068932.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068932.scexe"],"MD5Sum":"418cc2097a00dcfbb86abb2c7d1f1897","Name":"firmware-hdd-ec908c3650-HPG9-7.1.x86_64.rpm","Release":"2025-09-22T03:13:40","Revision":"G","SHA1Sum":"f92c4a86add6284c15d46de34777b8b0a200bcad","SHA256Sum":"eed535b7af58c3b55b5744e18fc06056deee3cfd5c6a31a979faa33e2d5c76e7","Size":"5MB","TargetGUIDs":["002340a5-4d00-324d-3030-304745465241"],"TypeOfChange":"1","Version":"HPG9"}],"Installation":{"Command":"CP040273.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MM2000GEFRA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM2000GEFRAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM2000GEFRA","TargetGUID":"002340a5-4d00-324d-3030-304745465241","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:14:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul>","Lang":"cn"}],"Version":"HPG9"}],"SWKeys":[{"Name":"MM2000GEFRA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fa7d4ab4a2a243a6b4e8ce62b0daaf7b"}]},{"ProductId":"e8a7c3696813408f916249b859b6b722","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following SATA drive model: MM1000GFJTE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MM1000GFJTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Enhancements/New Features :</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5700452","DateModified":"2025-09-21T22:24:27","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1/CP068933.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1/SAVGNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068933.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068933.scexe"],"MD5Sum":"d17010df504d6e23b837ecb99d14d5f4","Name":"firmware-hdd-95af9a555e-HPG6-7.1.x86_64.rpm","Release":"2025-09-22T03:14:04","Revision":"G","SHA1Sum":"4ea4580667d000b4cd2d04a328d99e91aeba567b","SHA256Sum":"bcfb43e56c23120f5e09220ce7427193d005732e996320edf21182becfe613c3","Size":"5MB","TargetGUIDs":["002340a5-4d00-314d-3030-3047464a5445"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP040344.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM1000GFJTEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM1000GFJTE","TargetGUID":"002340a5-4d00-314d-3030-3047464a5445","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T20:15:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul>","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MM1000GFJTE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3037e9a83dcc4cb8b2f5d02c49c2165a"}]},{"ProductId":"e387ceb63f224ab6a638f85cac2fa1d9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Ubuntu&nbsp;Linux (x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4643924","DateModified":"2025-08-02T21:12:25","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-1.1/CP067372.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-1.1/HVLPeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067372.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067372.scexe"],"MD5Sum":"6f952d19505ef1a64e2d89ecf637cd17","Name":"firmware-hdd-82894b9e0a_0HPG1-1.1_amd64.deb","Release":"2025-08-03T02:06:27","Revision":"","SHA1Sum":"9d5ae043b823a05078a49299b3133e077703727c","SHA256Sum":"187de1d8879cda82f5b9286866efd1b1ada9b6d20486c89b607809794d2dffa5","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP041482.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000GWRTC Drive"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000GWRTC Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000GWRTC","TargetGUID":"4d2340a5-3042-3830-3030-304757525443","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-29T20:54:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware fixes an issue where the drive can become inaccessible after an emergency power off, and corrects a potential verification issue during read recovery.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"72a0a27f09db4a51add243a77fa1d75a"}]},{"ProductId":"cf3d0ea161014094b2ae4ebd26456a93","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"6778526","DateModified":"2025-09-21T21:13:38","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/CP068917.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/HPG1_PM897.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068917.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068917.scexe"],"MD5Sum":"108298458f0b9f318f93cfa0ca2cdf76","Name":"firmware-hdd-9475583fb5-HPG1-6.1.x86_64.rpm","Release":"2025-09-22T02:02:43","Revision":"F","SHA1Sum":"36c9a3829f935c8161f3e1c0652d6dd08489765b","SHA256Sum":"c6bbc1f54ca33e16d38495cfacd8f9fcbb7ae4305aaa1298f8e83bb8e6373034","Size":"6MB","TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040346.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MK000480GZXRA","TargetGUID":"4d2340a5-304b-3030-3438-30475a585241","Type":"sata"},{"Id":"MK001920GZXRC","TargetGUID":"4d2340a5-304b-3130-3932-30475a585243","Type":"sata"},{"Id":"MK000960GZXRB","TargetGUID":"4d2340a5-304b-3030-3936-30475a585242","Type":"sata"},{"Id":"MK003840GZXRV","TargetGUID":"4d2340a5-304b-3330-3834-30475a585256","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-21T19:58:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL 10のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16</li></ul>","Fixes":"<ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"09fad2ae6ae840ae99f4ef37015c7219"}]},{"ProductId":"92d52e2161c24f8f9ff633da842f814c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK8</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK8</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"20412605","DateModified":"2025-03-19T05:19:40","FileList":["/CP066269_BUILD_1.data","/CP066269.vmexe64","/CP066269.vmfile","/CP066269_VMw.zip","/CP066269.xml","/payload.json","/CP066269_VMw.zip/index.xml","/CP066269_VMw.zip/vendor-index.xml","/CP066269_VMw.zip/metadata.zip","/CP066269_VMw.zip/vib20/CP066269/HPE_bootbank_CP066269_GPK8.1-8.0.0.20613240.vib","/CP066269_VMw.zip/metadata.zip/vendor-index.xml","/CP066269_VMw.zip/metadata.zip/vmware.xml","/CP066269_VMw.zip/metadata.zip/vibs/CP066269-4937708701175308295.xml","/CP066269_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066269_GPK8.1-8.0.0.20613240.xml"],"MD5Sum":"bfe95057121aff60575c869b198db646","Name":"CP066269.zip","Release":"2025-03-19T05:18:56","Revision":"B","SHA1Sum":"d21ef24dad8cf495035544bd265d77651f209748","SHA256Sum":"55018d0cb390c3550b11c0e713501919b0d67fee0c8bf72edc723ee86980660f","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8","VibList":[{"Name":"CP066269","Version":"GPK8.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCD6XLUL7T68","TargetGUID":"002340a5-434b-3644-584c-554c37543638","Type":"nvme"},{"Id":"KCD6XVUL6T40","TargetGUID":"002340a5-434b-3644-5856-554c36543430","Type":"nvme"},{"Id":"KCD6XVUL1T60","TargetGUID":"002340a5-434b-3644-5856-554c31543630","Type":"nvme"},{"Id":"KCD6XVUL800G","TargetGUID":"002340a5-434b-3644-5856-554c38303047","Type":"nvme"},{"Id":"KCD6XVUL3T20","TargetGUID":"002340a5-434b-3644-5856-554c33543230","Type":"nvme"},{"Id":"KCD6XVUL12T8","TargetGUID":"002340a5-434b-3644-5856-554c31325438","Type":"nvme"},{"Id":"KCD6XLUL960G","TargetGUID":"002340a5-434b-3644-584c-554c39363047","Type":"nvme"},{"Id":"KCD6XLUL1T92","TargetGUID":"002340a5-434b-3644-584c-554c31543932","Type":"nvme"},{"Id":"KCD6XLUL3T84","TargetGUID":"002340a5-434b-3644-584c-554c33543834","Type":"nvme"},{"Id":"KCD6XLUL15T3","TargetGUID":"002340a5-434b-3644-584c-554c31355433","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-18T12:10:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"GPK7"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed Reset issue and regular maintenance firmware update.</li></ul>","Lang":"cn"}],"Version":"GPK8"}],"SWKeys":[{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9ee8bc81871a46219e0901843d2c0086"}]},{"ProductId":"189fb9052e994ac694bd5d6fb410f76a","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for MicroServerv2 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SC_MicroServerv2GEN10Plus_ME_06.00.03.708.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2283691","DateModified":"2025-08-04T03:55:17","FileList":["payload.json","SC_MicroServerv2GEN10Plus_ME_06.00.03.708.signed.bin","SC_MicroServerv2GEN10Plus_ME_06.00.03.708.xml"],"MD5Sum":"bbd949311c6759a4e3a558b81e64c709","Name":"SC_MicroServerv2GEN10Plus_ME_06.00.03.708.fwpkg","Release":"2025-08-04T03:53:52","Revision":"","SHA1Sum":"308a001e6fdb7c114b6e39aa9bd6049cab6f39f9","SHA256Sum":"6bb10e080b23bafb83c86f645c531fa3a771a82af124993f9b9a538eb371ca11","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2 Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services (SPS)ファームウェアfor HPE ProLiant MicroServer Gen10 Plus v2サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-09-04T03:32:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.700 (2.30_01_07_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"},{"ReleaseNotes":[{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"en"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"ja"},{"Enhancements":"Resolved various issues to improve system stability and performance.","Fixes":"Resolved various issues to improve system stability and performance.","Lang":"cn"}],"Version":"06.00.03.708"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"352e23b716be4102b972bb4003d4db6c"}]},{"ProductId":"738515ca087c45c4b01b62883007bfb8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3 Drive<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;MPK7825Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>提供名：</strong><br />      オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3ドライブ<br /> <br /><strong>リリースバージョンおよび/または日付：</strong><br />      MPK7825Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>最新の推奨またはクリティカルバージョン：</strong><br />      MPK7625Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>前のファームウェアバージョン：</strong><br />      MPK7625Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ファームウェアの依存関係：<br />      </strong>なし</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>修正された問題点：</strong></p><ul><li>発生する可能性がある修正不可能なマシンチェック例外(UMCE)の問題を修正しました。</li><li>詳しくは、HPEカスタマーアドバイザリ： <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>既知の問題点：</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     </strong>なし</p>"}],"Files":[{"Bytes":"27552301","DateModified":"2025-03-06T11:41:13","FileList":["/CP065945_BUILD_4.data","/CP065945.vmexe64","/CP065945.vmfile","/CP065945_VMw.zip","/CP065945.xml","/payload.json","/CP065945_VMw.zip/index.xml","/CP065945_VMw.zip/vendor-index.xml","/CP065945_VMw.zip/metadata.zip","/CP065945_VMw.zip/vib20/CP065945/HPE_bootbank_CP065945_MPK7825Q.4-1OEM.800.1.0.20613240.vib","/CP065945_VMw.zip/metadata.zip/vendor-index.xml","/CP065945_VMw.zip/metadata.zip/vmware.xml","/CP065945_VMw.zip/metadata.zip/vibs/CP065945--2221472532043157979.xml","/CP065945_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065945_MPK7825Q.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"0d8e8a3e65724dd9473652a3c34722ef","Name":"CP065945.zip","Release":"2025-03-06T11:40:26","Revision":"B","SHA1Sum":"d92fb51d78b9ded59f920ab0ee45357ca29c9efd","SHA256Sum":"b91f0305bcd2c3fa0cdea1e70aa68460a841b82d296d27061871fb9d42f79532","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"2","Version":"MPK7825Q","VibList":[{"Name":"CP065945","Version":"MPK7825Q.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H Drive"},{"Lang":"ja","Value":"VMware ESXi用オンラインNVMe SSDフラッシュコンポーネント - MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000Hドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXLR12THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3132-544869b8df72","Type":"nvme"},{"Id":"MZXLR15THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3135-5448e88a517e","Type":"nvme"},{"Id":"MZXLR7T6HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3754-36484bc80db1","Type":"nvme"},{"Id":"MZXLR1T6HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Type":"nvme"},{"Id":"MZXLR800HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3830-3048c3876295","Type":"nvme"},{"Id":"MZXLR3T2HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3248a4bea716","Type":"nvme"},{"Id":"MZXLR6T4HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Type":"nvme"},{"Id":"MZXLR1T9HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3948cda93afa","Type":"nvme"},{"Id":"MZXLR3T8HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3848df400867","Type":"nvme"},{"Id":"MZXLR960HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3936-3048d2d64915","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:30:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>発生する可能性がある修正不可能なマシンチェック例外(UMCE)の問題を修正しました。</li><li>詳しくは、HPEカスタマーアドバイザリ： <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK7825Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK7825Q"}],"SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0e038dbf393b4835a98f9e12bce3c8cc"}]},{"ProductId":"6510bb61b44e4df589649e5642d32bf1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作するIntel i40ea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1249232","DateModified":"2025-11-16T10:27:13","FileList":["cp069536.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"59187622192e13ef349dc7feccb89e3e","Name":"cp069536.exe","Release":"2025-11-16T10:12:27","Revision":"B","SHA1Sum":"77e9ee141bc8b620626e75f6f81b79ba3d8bf0ae","SHA256Sum":"9857fbaeb0bf013b2419e5ac5ded18e67112c058720d8dfd5ceab65c7679d59a","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"TypeOfChange":"1","Version":"1.22.91.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i40ea Driver for Windows Server 2019"},{"Lang":"ja","Value":"Intel i40eaドライバーfor Windows Server 2019"},{"Lang":"cn","Value":"Intel i40ea Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"cn"}],"Version":"1.22.91.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"en"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"ja"},{"Enhancements":"<p>This product enhanced traffic flow in queue map rebalance.</p>","Fixes":"<p>This product fixed the BSOD during the RX queue initialization.</p>","Lang":"cn"}],"Version":"1.22.91.0"}],"SWKeys":[{"Name":"i40ea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"f1361761f78a4dc4a82fbef98f7f6865"}]},{"ProductId":"fa3afb08b69b4eb3ac32d9088c68d3a9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Addresses a hot plug reporting concern.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li><li>Remove Background Media Scan (BMS) with Super parity and Directed Offline Scan (DOS).</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for SLES16.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Addresses a hot plug reporting concern.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li><li>Remove Background Media Scan (BMS) with Super parity and Directed Offline Scan (DOS).</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6241887","DateModified":"2025-09-17T12:13:11","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/CP068803.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/SHPEEVANSSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068803.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068803.scexe"],"MD5Sum":"787e9995e11e8abf41e33f0e3b053d30","Name":"firmware-hdd-cf0b6cabe1-HPD4-7.1.x86_64.rpm","Release":"2025-09-17T17:02:04","Revision":"G","SHA1Sum":"515b9ebcc8c5757af109f083e33fb11bf9893f05","SHA256Sum":"67284f4ff7c7f67c7f7977ab7f4a3561e40dc36633e57443400935af765847d6","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64） - MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000JWZHA","TargetGUID":"4d2340a5-3042-3031-3030-304a575a4841","Type":"sas"},{"Id":"MB016000JWZHE","TargetGUID":"4d2340a5-3042-3631-3030-304a575a4845","Type":"sas"},{"Id":"MB014000JWZHC","TargetGUID":"4d2340a5-3042-3431-3030-304a575a4843","Type":"sas"},{"Id":"MB012000JWZHB","TargetGUID":"4d2340a5-3042-3231-3030-304a575a4842","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-15T03:51:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for SLES16.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c412afec4b864fbe9252ae577a0a28fa"}]},{"ProductId":"be56d38accd045cca89d446f2db8440b","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3865.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_FVL4HP.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3865.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains utilities and firmware for HPE ProLiant Gen9 and Gen10 server series the online upgrade of HPE Intel NIC firmware running under Microsoft Windows Server 2019, Windows Server 2022 and Windows Server 2025"},{"Lang":"ja","Value":"このコンポーネントには、Microsoft Windows Server 2019、Microsoft Windows Server 2022、およびWindows Server 2025で動作するHPE Intel NICファームウェアをオンラインでアップグレードするための、HPE ProLiant Gen9およびGen10サーバーシリーズのユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12756816","DateModified":"2025-11-14T04:55:56","FileList":["cp069553.xml","cpqsetup.exe","for_Gen9/","for_Gen9/install.bat","for_Gen9/iqvw64e.cat","for_Gen9/iqvw64e.inf","for_Gen9/iqvw64e.sys","for_Gen9/uninstall.bat","FW/","FW/BootIMG.FLB","FW/BootIMG_FVL4HP.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP.txt","FW/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.txt","FW/HPE_361T.txt","FW/HPE_361T_H65030-003_2.25_80001147.txt","FW/HPE_366FLR_G41713-00x_800011A1.txt","FW/HPE_366T_MAP.txt","FW/HPE_366T_Quad_H73104-00x_800011F1.txt","FW/HPE_369i_88E1512_P01_88E1512_P23_NCSI_6p00_80003AC3.bin","FW/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","FW/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","FW/HPE_40G_Adapter_VPD_MAP.txt","FW/HPE_562FLR-SFP_DP_H47655-000_11p1p7_9p50_8000F231.bin","FW/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","FW/HPE_562SFP_DP_H44490-000_11p1p7_9p50_8000F232.bin","FW/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","FW/HPE_563i_KR_DP_800035C0.bin","FW/HPE_568i_Backplane_2x10G_P01_NCSI_6p00_80003AC4.bin","FW/HPE_Apollo_PHY_Auto_Detect_NCSI_6p00_80003AC2.bin","FW/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_6p00_80003AC5.bin","FW/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","FW/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","FW/HPE_XG_SGVL_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"224311babe3d365a47ff95583dffbef6","Name":"cp069553.exe","Release":"2025-11-14T04:46:59","Revision":"B","SHA1Sum":"a29e3202f22b5ef6e508ce74fa1bcd3657cf867a","SHA256Sum":"289610ee2ea0cde2bb2011a1f8a85dfea937d523bed195f0ee85bac69675c4c0","Size":"12MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"5.4.6.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":3600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","SWKey":"e1r63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","SWKey":"e1r64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","SWKey":"e1r65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","SWKey":"ixn63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","SWKey":"ixt63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","SWKey":"ixt64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","SWKey":"ixn64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","SWKey":"ixt65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","SWKey":"ixn65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","SWKey":"i40ea63.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","SWKey":"i40ea64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","SWKey":"i40ea65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","SWKey":"ixs64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","SWKey":"ixs65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","SWKey":"i40eb65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","SWKey":"i40eb64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","SWKey":"e1r68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","SWKey":"i40ea68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","SWKey":"i40eb68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","SWKey":"ixn68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","SWKey":"ixs68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","SWKey":"ixt68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.1.197.0"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","SWKey":"icea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","SWKey":"iavf.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","SWKey":"ixs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","SWKey":"vxs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 2-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。ダウングレードに関する制限について詳しくは、カスタマーアドバイザリhttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_usを参照してください。</li><li>次のネットワークアダプターについては、アップデートを反映させるためにファームウェアのインストール後にAC電源を再投入する必要があります。<br />HPE Ethernet 1Gb 2ポート 368iアダプター<br />HPE Ethernet 1Gb 2ポート369iアダプター<br />HPE Ethernet 1Gb 2ポート368FLR-MMTアダプター <br />HPE Ethernet 10Gb 2ポート568FLR-MMSFP+アダプター<br />HPE Ethernet 10Gb 2ポート568FLR-MMTアダプター</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel Online Firmware Upgrade Utility for Windows Server x64 Editions for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"ja","Value":"HPE Intelオンラインファームウェアアップグレードユーティリティfor Windows Server x64 Editions（HPE ProLiant Gen9およびGen10サーバーシリーズ専用）。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4100"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-13T07:51:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed PXE Boot does not work when DMA remapping is enabled in AMD platform.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed PXE Boot does not work when DMA remapping is enabled in AMD platform.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed PXE Boot does not work when DMA remapping is enabled in AMD platform.</p>","Lang":"cn"}],"Version":"5.4.6.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed PXE Boot does not work when DMA remapping is enabled in AMD platform.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed PXE Boot does not work when DMA remapping is enabled in AMD platform.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed PXE Boot does not work when DMA remapping is enabled in AMD platform.</p>","Lang":"cn"}],"Version":"5.4.6.0"}],"SWKeys":[{"Name":"HPNVMUpdate.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"445f491396d8448eba420dcedec44ce2"}]},{"ProductId":"5156ee2ce74d4685bd9c2931c6170220","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.<br />* The previous web release iavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (hp-iavf-kmp-default) to (iavf-kmp-default). Now we revert this change from (iavf-kmp-default) to (<strong>hp</strong>-iavf-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-iavf-kmp-default and iavf-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install iavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e iavf-kmp-default and then install the updated RPM.</li></ul>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。<br />* 以前のWebリリースiavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（hp-iavf-kmp-default）から（iavf-kmp-default）に変更されました。この変更を（iavf-kmp-default）から（<strong>hp</strong>-iavf-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-iavf-kmp-defaultとiavf-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにiavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e iavf-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</li></ul>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.<br />* The previous web release iavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (hp-iavf-kmp-default) to (iavf-kmp-default). Now we revert this change from (iavf-kmp-default) to (<strong>hp</strong>-iavf-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-iavf-kmp-default and iavf-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install iavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e iavf-kmp-default and then install the updated RPM.</li></ul>"}],"Files":[{"Bytes":"186617","DateModified":"2025-09-15T16:15:09","FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-iavf","./lib/modules/6.4.0-150700.51-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"MD5Sum":"a5cd4c05e0a9253fcccd4e8ed4c92d3c","Name":"hp-iavf-kmp-default-4.13.16_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-09-15T16:07:05","Revision":"","SHA1Sum":"255c962aad06b9218281578b719e70120709f240","SHA256Sum":"041a786fa7f3ede205e4fbccf1bd94b5323fd6f66c00c44b41f4a173a5573e42","Size":"182KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"TypeOfChange":"1","Version":"4.13.16-1"},{"Bytes":"186771","DateModified":"2025-09-15T16:20:16","FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-iavf","./lib/modules/6.4.0-150600.21-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"MD5Sum":"8a04545c425daf96d488a01e59ab0c85","Name":"hp-iavf-kmp-default-4.13.16_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-09-15T16:07:05","Revision":"","SHA1Sum":"6c8c31dedd60ff9d29c33121ae5bc714ddb691f1","SHA256Sum":"98c7abea6dc14c25a57dafeddf177d29a838487252130637ccf00493cd392593","Size":"182KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"TypeOfChange":"1","Version":"4.13.16-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel iavfドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"15FF","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15ff8086000c","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"37cd","Type":"pci","Ven":"8086"},{"Dev":"0dd5","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"12D3","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-12d380860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-22T08:13:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes default number of queues to resolve RSS issues.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、RSSの問題を解決するためにデフォルトのキューの数を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes default number of queues to resolve RSS issues.</p>","Lang":"cn"}],"Version":"4.13.14-1"},{"ReleaseNotes":[{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"<p>Initial version.</p>","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"4.13.16-1"}],"SWKeys":[{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b86bfe25c6d74118b9182e299f8d2d0b"}]},{"ProductId":"c549eb5726da4e0ab54cbcdd6abecebd","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品は、Red Hat Enterprise Linux 9下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1311259","DateModified":"2025-12-12T06:34:38","FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"MD5Sum":"7bc76f15dbd260c62f82846282bca9d3","Name":"kmod-bnxt_en-1.10.3-235.1.164.14.rhel9u6.x86_64.rpm","Release":"2025-12-12T06:28:30","Revision":"","SHA1Sum":"f91a202c0be91e2c4948199df44995864ebc0b22","SHA256Sum":"9f8d36250ac3add21b6bc4126530ef1b4aabff28239a948448e2ded8eab348cf","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-235.1.164.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-01-12T04:04:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"1.10.3-235.1.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the issue where 10Gb SFP (SP7053-HPE) adapters are unable to establish a link after rebooting with BCM 57504 and 5741x adapters</li><li>This product fixes the issue where BCM5741x NICs no longer connect after firmware 228.x FW with 10Gb-RJ45 Transceivers</li></ul>","Lang":"cn"}],"Version":"1.10.3-235.1.164.14"}],"SWKeys":[{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"66e0ee09018e463c9b0da88f6f3702f5"}]},{"ProductId":"83fed5e4a427414fb0792283dd57ec37","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"801448","DateModified":"2025-11-18T08:26:01","FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"MD5Sum":"02550461fd5982b70b6f7d8ac0a427ec","Name":"elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-11-18T08:21:05","Revision":"","SHA1Sum":"0f705d7c02b00387039f0de0a773ede33ff1cc05","SHA256Sum":"0f810a90bc2c9b16202fb6e50e1bd12d91ac2dc8ef58fc7747e7ac11dbeacb66","Size":"782KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.731.6"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.520.3_k5.14.21_150500.37-1.sles15sp5.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"ja","Value":"<p>1. システム管理者（root）としてログインします。</p><p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br /><br />                    # rpm -Uvh elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64.rpm<br /><br />                    例：# rpm -Uvh elx-lpfc-kmp-default-14.2.520.3_k5.14.21_150500.37-1.sles15sp5.x86_64.rpm</p><p>4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。 </p><p><strong>重要：</strong>インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br /><br />                    # rpm -e elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64</p><p>同じドライバーバージョンの書き換えは、--reinstallオプションを使用して実行する必要があります</p><p>例：rpm –Uvh elx-lpfc-kmp-default-<version>.<OSupdate>.x86_64.rpm --reinstall</p><p>詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.520.3_k5.14.21_150500.37-1.sles15sp5.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"},{"Lang":"ja","Value":"SUSE Linux Enterprise Server 15 Service Pack 7ファイバーチャネルドライバーキットfor HPE Emulexホストバスアダプター"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-26T05:10:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>SuSE Linux Enterprise 15 SP&nbsp;7</p><p>Updated to&nbsp;version 14.4.473.26</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>SuSE Linux Enterprise 15 SP 7</p><p>バージョン14.4.473.26にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>SuSE Linux Enterprise 15 SP&nbsp;7</p><p>Updated to&nbsp;version 14.4.473.26</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.26"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to&nbsp;version&nbsp;14.4.731.6</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.731.6"}],"SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3be72de3c7ed4d1b94905d0eb772f557"}]},{"ProductId":"c9a566daebdb4bd4a0f22d28877b9f3b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 9.0."},{"Lang":"cn","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 9.0."},{"Lang":"ja","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"},{"Lang":"cn","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"},{"Lang":"ja","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"}],"Files":[{"Bytes":"1521204","DateModified":"2024-12-10T08:29:42","FileList":["/cp064706.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"MD5Sum":"a7a16c4d0961276292bc0a9f6a333f20","Name":"cp064706.zip","Release":"2024-12-10T08:29:21","Revision":"","SHA1Sum":"2ff1dfe747d5f41859f19fd09e3223db00c3fb8c","SHA256Sum":"921afb4c0acb174e8a1c264b62d0de48e38893eb65300023e0689b990162b16a","Size":"1MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-09T05:38:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.03.00"}],"SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5b72663a36ec4ac2a8e3084a2ac63e87"}]},{"ProductId":"ed9a4b98eb61471ab66480b22d4e9c4f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Local 24H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"4279560","DateModified":"2025-11-17T14:24:21","FileList":["cp068658.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SMOBULABPTG2.rel"],"MD5Sum":"4b0c0a25aaae5e59c8996a66788f5cc1","Name":"cp068658.exe","Release":"2025-11-17T14:19:12","Revision":"J","SHA1Sum":"2874b0150038b077f4e6a38e04b2dc5b5a18e005","SHA256Sum":"cac170f20d7b045e706ed24e1659f1788be4930024d44725449a246d8529ba86","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000GWRTN","TargetGUID":"4d2340a5-3042-3431-3030-30475752544e","Type":"sata"},{"Id":"MB012000GWRTL","TargetGUID":"4d2340a5-3042-3231-3030-30475752544c","Type":"sata"},{"Id":"MB010000GWRTK","TargetGUID":"4d2340a5-3042-3031-3030-30475752544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-08T09:49:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Local 24H2</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0055eb2e6f1a4b82856baa2214762650"}]},{"ProductId":"6f38004b166d42068a292e455179565f","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3438-304759434e54","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3936-304759434e50","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3130-3932-304759434e46","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3330-3834-304759434e51","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3234-304759434e55","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3438-304759434e48","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3936-304759434e4b","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-304759434e4c","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3330-3834-304759434e4e","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3730-3638-304759434e45","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3234-304758505154","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304758505155","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[],"Files":[{"Bytes":"1493893","DateModified":"2024-10-17T06:15:15","FileList":["payload.json","Solidigm_S4X20_4IYYHPG4.HPb","Solidigm_S4X20_4IYYHPG4.xml"],"MD5Sum":"d6a443e6c3505bc7a1ba75be546c9b21","Name":"Solidigm_S4X20_4IYYHPG4.fwpkg","Release":"2024-10-17T06:12:40","Revision":"","SHA1Sum":"f1041efa62e599fbc3fc7927ea2e7f8c437aba16","SHA256Sum":"1f73fa1d0c76689516d832aef9c140a9920809276addd57dad0495375425afc1","Size":"1MB","TargetGUIDs":["4d2340a5-304b-3030-3438-304759434e54","4d2340a5-304b-3030-3936-304759434e50","4d2340a5-304b-3130-3932-304759434e46","4d2340a5-304b-3330-3834-304759434e51","562340a5-304b-3030-3234-304759434e55","562340a5-304b-3030-3438-304759434e48","562340a5-304b-3030-3936-304759434e4b","562340a5-304b-3130-3932-304759434e4c","562340a5-304b-3330-3834-304759434e4e","562340a5-304b-3730-3638-304759434e45","562340a5-3052-3030-3234-304758505154","562340a5-3052-3030-3438-304758505155"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MK000480GYCNT","TargetGUID":"4d2340a5-304b-3030-3438-304759434e54","Type":"sata"},{"Id":"MK000960GYCNP","TargetGUID":"4d2340a5-304b-3030-3936-304759434e50","Type":"sata"},{"Id":"MK001920GYCNF","TargetGUID":"4d2340a5-304b-3130-3932-304759434e46","Type":"sata"},{"Id":"MK003840GYCNQ","TargetGUID":"4d2340a5-304b-3330-3834-304759434e51","Type":"sata"},{"Id":"VK000240GYCNU","TargetGUID":"562340a5-304b-3030-3234-304759434e55","Type":"sata"},{"Id":"VK000480GYCNH","TargetGUID":"562340a5-304b-3030-3438-304759434e48","Type":"sata"},{"Id":"VK000960GYCNK","TargetGUID":"562340a5-304b-3030-3936-304759434e4b","Type":"sata"},{"Id":"VK001920GYCNL","TargetGUID":"562340a5-304b-3130-3932-304759434e4c","Type":"sata"},{"Id":"VK003840GYCNN","TargetGUID":"562340a5-304b-3330-3834-304759434e4e","Type":"sata"},{"Id":"VK007680GYCNE","TargetGUID":"562340a5-304b-3730-3638-304759434e45","Type":"sata"},{"Id":"VR000240GXPQT","TargetGUID":"562340a5-3052-3030-3234-304758505154","Type":"sata"},{"Id":"VR000480GXPQU","TargetGUID":"562340a5-3052-3030-3438-304758505155","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-17T05:48:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>HPG3 is a planned maintenance release covering bug fixes for 2.5&rdquo; and M.2.&nbsp;There are no critical functional updates, and risk is low for customers who do not upgrade, especially if drives are not stored without power for a long period of time (~2 years).</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>HPG3 is a planned maintenance release covering bug fixes for 2.5&rdquo; and M.2.&nbsp;There are no critical functional updates, and risk is low for customers who do not upgrade, especially if drives are not stored without power for a long period of time (~2 years).</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>HPG3 is a planned maintenance release covering bug fixes for 2.5&rdquo; and M.2.&nbsp;There are no critical functional updates, and risk is low for customers who do not upgrade, especially if drives are not stored without power for a long period of time (~2 years).</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a planned maintenance release covering bug fixes. This firmware includes updates to improve PLI circuit reliability.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This is a planned maintenance release covering bug fixes. This firmware includes updates to improve PLI circuit reliability.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a planned maintenance release covering bug fixes. This firmware includes updates to improve PLI circuit reliability.</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MK000480GYCNT","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK000960GYCNP","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK001920GYCNF","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK003840GYCNQ","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000240GYCNU","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000480GYCNH","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000960GYCNK","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK001920GYCNL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK003840GYCNN","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK007680GYCNE","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VR000240GXPQT","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VR000480GXPQU","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"8ae279136d1146d9a07e0ced51a7a9cd"}]}],"Prerequisites":[{"ProductId":"b8e6a95559f244b1942217b8d607ed1e","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains NVM Image version 226.1.107000&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains NVM Image version 226.1.107000&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains NVM Image version 226.1.107000&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"}],"Files":[{"Bytes":"7504207","DateModified":"2024-10-15T01:39:45","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/CP063801.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/CP063801.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063801.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063801.scexe"],"MD5Sum":"713c039afa52686e3d8c4b76e6ed0873","Name":"firmware-nic-bcm-nxe-226.1.107000-2.1.x86_64.rpm","Release":"2024-10-15T06:32:46","Revision":"B","SHA1Sum":"36dfe0e391765fd2ac85c7d0b65899477a76ef28","SHA256Sum":"84deef16f9de9a52ea96971958446c5f44d1493311252312c9481b0f17647189","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-07T05:01:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"cn"}],"Version":"226.1.107000"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"8526d39348f74098b531f4e3046eb634"}]},{"ProductId":"2dc80c4ae4b943faadb938f8fc2b61d5","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_148.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides updated iLO firmware that can be installed directly on supported Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HPE Smart Update Manager."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、HPE Smart Update Managerと一緒に使用することができます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hp.com/go/ilo\">http://www.hpe.com/go/ilo</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p> </p><p>また、『iLO 5ユーザーガイド』および『Lights-Outスクリプティングガイド』も下記のリンクから入手できます:<br /><br /><a href=\"http://www.hp.com/go/ilo\">http://www.hpe.com/go/ilo</a><br /><br />ご使用のLights-Out製品、サポート&ドキュメント、ドキュメントの順に選択します。<br /> </p><ul><li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />オンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li></ul>"}],"Files":[{"Bytes":"33589045","DateModified":"2024-04-12T18:09:59","FileList":["ilo5_148.bin","ilo5_148.xml","payload.json","readme.txt"],"MD5Sum":"de8ae806c0a656958c290dae02db2314","Name":"ilo5_148.fwpkg","Release":"2024-04-12T18:05:45","Revision":"b","SHA1Sum":"4c4d88b03e90aa72a7431af3e45d5e6b264b2a2d","SHA256Sum":"48e02049b5a8acf552f82b668bc860d41e1ec7910e572a5820b04224a296026c","Size":"32MB","TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"0","Version":"1.48"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" target=\"_blank\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュファームウェアパッケージ - HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"70000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-03-13T11:19:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>iLO 5の旧バージョンのiLO 5でサポートしているすべてのDCiオプションに対して set server info コマンドを実装し、iLO 5のアップデート中にNICの設定をリセットする可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"cn"}],"Version":"1.48"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"cn"}],"Version":"1.48"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"f0bb94c6dff64cb39c8fb14c2dedf4c0"}]},{"ProductId":"b3a8e7e2c4ea466a9b404955f474449e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"cn","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"ja","Value":"Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の資格証明書を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはiLO Amplifierパックまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerバージョン8.0.0以降および展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"7818457","DateModified":"2024-10-30T05:03:48","FileList":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/lib/.build-id","./usr/lib/.build-id/57","./usr/lib/.build-id/57/374c6b2b55c3ea60f4ebaa7dfd1667b9b459f6","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/d01fe263104c65c66707eca3d31d173f66dc7e","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"MD5Sum":"afa1ae18bde501b0f3327a62759ae1f5","Name":"sut-5.3.0-10.linux.x86_64.rpm","Release":"2024-10-30T09:59:06","Revision":"","SHA1Sum":"a2b72c34666e502c4a3379b4a97704a8e34013dc","SHA256Sum":"2a57a95284f853d4a4338e62d4e1941b0deed177cbc351d212f95d5fc8904afc","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"5.3.0.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"},{"Lang":"ja","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"},{"Lang":"cn","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Integrated Smart Update Tools for Linux x64"},{"Lang":"cn","Value":"Integrated Smart Update Tools for Linux x64"},{"Lang":"ja","Value":"Integrated Smart Update Tools for Linux x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-23T12:48:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"5.2.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"5.3.0.0"}],"SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HP Smart Update Tools (HP SUT)"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"151e85c53b0b4ca0b072e7b487d0ff4f"}]},{"ProductId":"8384f9a8878649da8d668b07fb30c48e","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_148.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides and installs an updated version of firmware for the iLO 5 Management Processor allowing for continued management support of your Server."},{"Lang":"ja","Value":"このコンポーネントは、iLO 5マネジメントプロセッサーがご使用のサーバーを継続して管理サポートできるようアップデートされたバージョンのファームウェアを提供しインストールします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><a href=\"http://www.hpe.com/info/ilo-docs\" rel=\"noopener noreferrer\" target=\"_blank\">http://www.hpe.com/info/ilo-docs</a><br />Select your lights-out product, then support &amp; documents, then manuals.</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p> </p><p>また、『iLO 5ユーザーガイド』および『Lights-Outスクリプティングガイド』も下記のリンクから入手できます：<br /><a href=\"http://www.hpe.com/info/ilo-docs\" rel=\"noopener noreferrer\" target=\"_blank\">http://www.hpe.com/info/ilo-docs</a><br />ご使用のLights-Out製品、サポート&ドキュメント、ドキュメントの順に選択します。</p><ul><li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />オンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li></ul>"}],"Files":[{"Bytes":"17881416","DateModified":"2026-01-16T09:30:20","FileList":["cp070139.xml","cpqsetup.exe","ilo5_148.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"MD5Sum":"057618132438c6e73626ddafb71af78d","Name":"cp070139.exe","Release":"2026-01-16T09:27:55","Revision":"c","SHA1Sum":"eb1bc70dac2542fad3208d595b311f7d59d60505","SHA256Sum":"e2a1cdebe8aeeae1439eb454f74d8123e23de5581bc617ed0f51045aa289894e","Size":"17MB","TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"1","Version":"1.48"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Install the firmware using one of these options:</strong></p><ul><li>Run the Component on the host to be updated.<br />The component will update the iLO 5&nbsp;firmware and reset the iLO 5&nbsp;processor.<br />&nbsp;</li><li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO5_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:<ul><li>Login to iLO 5, navigate to the Update Firmware page, and update the firmware from there.</li><li>Use the HPE Lights-Out Configuration Utility, and RIBCL/XML scripts to update iLO 5&nbsp;across the network.</li><li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO 5&nbsp;from the supported host OS.</li><li>Use the Directory Migration Utility, contained in the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_13aa310d9f23432a8d02d5ad56#tab6\">HPE Directories support for Management Processors</a>, &nbsp;The Windows utility supports&nbsp;network discovery of lights-out processors, import/export, as well as bulk firmware update, and does not require directory migration.</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>以下のいずれかのオプションを使用してファームウェアをインストールしてください。</strong></p><ul><li>アップデートするホスト上のコンポーネントを実行します。<br />このコンポーネントは、iLO 5ファームウェアをアップデートし、iLO 5プロセッサーをリセットします。<br /> </li><li>コンポーネントからファームウェアを抽出します。  これにより、iLO5_yyy.bin（yyyはファームウェアバージョン）がターゲットディレクトリにコピーされます。  以下のオプションがあります。<ul><li>iLO 5にログインし、ファームウェアのアップデートページに移動して、そこからファームウェアをアップデートします。</li><li>ネットワーク経由でiLO 5をアップデートするには、HPE Lights-Out構成ユーティリティおよびRIBCL/XMLスクリプトを使用します。</li><li>サポートされているホストOSからiLO 5をアップデートするには、HPE Online Lights-Out構成ユーティリティ、HPONCFG、およびRIBCL/XMLスクリプトを使用します。</li><li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_13aa310d9f23432a8d02d5ad56#tab6\">HPE Directories support for Management Processors</a>に含まれているDirectory Migrationユーティリティを使用します。このWindowsユーティリティでは、Lights-Outプロセッサーのネットワーク検出、インポート/エクスポート機能、およびバルクファームウェアアップデートをサポートしており、ディレクトリの移行は不要です。</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64- HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5120"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"1","Name":"Microsoft Windows 7 (64-bit) - All Editions","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows 8.1 (64-bit)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012","Platform":"nt_x86-64","Sr":"OEM"},{"Edition":"Essentials","Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012 Essentials","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Microsoft Windows Vista (64-bit)","Platform":"nt_x86-64","Sr":"OEM"},{"Edition":"ent","Major":"6","Minor":"0","Name":"Microsoft Windows Vista Enterprise (64-bit)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"5","Minor":"1","Name":"Microsoft Windows XP 64-Bit Edition","Platform":"NT64","Sr":"OEM"},{"Major":"5","Minor":"2","Name":"Microsoft Windows XP Professional x64 Edition","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2026-02-07T11:47:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>None</p>","Fixes":"<p>Enabling installation in OS FIPS mode.</p>","Lang":"en"},{"Enhancements":"<p>なし</p>","Fixes":"<p>OS FIPSモードでのインストールを有効にします。</p>","Lang":"ja"},{"Enhancements":"<p>None</p>","Fixes":"<p>Enabling installation in OS FIPS mode.</p>","Lang":"cn"}],"Version":"1.48"},{"ReleaseNotes":[{"Enhancements":"<p>None</p>","Fixes":"<p>Bundled the latest Smart Component Tool version to ensure Seamless Signing with appropriate Digital Certificate.</p>","Lang":"en"},{"Enhancements":"<p>なし</p>","Fixes":"<p>Bundled the latest Smart Component Tool version to ensure Seamless Signing with appropriate Digital Certificate.</p>","Lang":"ja"},{"Enhancements":"<p>None</p>","Fixes":"<p>Bundled the latest Smart Component Tool version to ensure Seamless Signing with appropriate Digital Certificate.</p>","Lang":"cn"}],"Version":"1.48"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"47c837c7bc774252a1748f8034d30097"}]},{"ProductId":"6adb26c5fc564f219877ab6a448e709b","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15938086000c","Version":"4.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA4 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28&nbsp;OCP3</td><td>80017788</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 OCP3</td><td>80017788</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.2と示されます</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28&nbsp;OCP3</td><td>80017788</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"}],"Files":[{"Bytes":"10520370","DateModified":"2023-07-07T04:26:48","FileList":["HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.HPb","HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.xml","payload.json"],"MD5Sum":"ecdfc15a5973ff1e19f9f1dec9628e95","Name":"HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.fwpkg","Release":"2023-07-19T00:00:00","Revision":"","SHA1Sum":"035edc90e72969b4a023d4620531de0006bad125","SHA256Sum":"25858cd4cb92a97b30435fa1f770ffe9c418a132f16bc1c09be8bc8077e23c40","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000c"],"TypeOfChange":"1","Version":"4.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 OCP3アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-12-29T08:12:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<p>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"cn"}],"Version":"4.20"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<ul><li>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</li><li>この製品は、UMCEが表示される問題に対処します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"cn"}],"Version":"4.20"}],"SWKeys":[{"Name":"INTEL_E810_XXV4OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"fa5c4d9893734e3caf9b762acf4eb5bd"}]},{"ProductId":"a225a11fa25340779e2e488c7b569a20","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2019 and Windows Server 2022."},{"Lang":"ja","Value":"このパッケージには、Microsoft Windows Server 2019とWindows Server 2022で動作する HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3112168","DateModified":"2025-11-20T07:56:20","FileList":["cp069753.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"ceb5055080c50abc559cba15c3109147","Name":"cp069753.exe","Release":"2025-11-20T07:48:05","Revision":"D","SHA1Sum":"f4de67e356ae382d872f093571a758232e720cbf","SHA256Sum":"f1821ebb7e0d4ff2d557fdbd5fd739752d49109a61b05d939969014370d23154","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","SWKey":"qevbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.37.37.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-20T06:55:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"en"},{"Enhancements":"<p>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</p>","Fixes":"<p>この製品は、iPXEブートを試行しているときのスイッチのPause Flood状態に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"QLBBFWUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"cc98c2801e0d41d9863df18abc24c4e0"}]},{"ProductId":"dedfd9d7098c498bab2315e3fb7e4b66","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR216i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.26.3.5487"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The ESXi Smart Component provides controller firmware for HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ESXi Smartコンポーネントは、HPE MR216i-a Gen10 Plusトライモードコントローラー用のコントローラーファームウェアを提供します"},{"Lang":"cn","Value":"The ESXi Smart Component provides controller firmware for HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>HPEMR216i-a&nbsp;Online FW Update with OS command option.</p>"},{"Lang":"ja","Value":"<p>OSコマンドオプションを使用したHPEMR216i-aオンラインFWアップデート。</p>"},{"Lang":"cn","Value":"<p>HPEMR216i-a&nbsp;Online FW Update with OS command option.</p>"}],"Files":[{"Bytes":"13070385","DateModified":"2025-03-07T07:05:19","FileList":["/CP066014_BUILD_13.data","/CP066014.vmexe64","/CP066014.vmfile","/CP066014_VMw.zip","/CP066014.xml","/payload.json","/CP066014_VMw.zip/index.xml","/CP066014_VMw.zip/vendor-index.xml","/CP066014_VMw.zip/metadata.zip","/CP066014_VMw.zip/vib20/CP066014/HPE_bootbank_CP066014_52.26.3.5487.13-8.0.0.20613240.vib","/CP066014_VMw.zip/metadata.zip/vendor-index.xml","/CP066014_VMw.zip/metadata.zip/vmware.xml","/CP066014_VMw.zip/metadata.zip/vibs/CP066014-3880614203087116731.xml","/CP066014_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066014_52.26.3.5487.13-8.0.0.20613240.xml"],"MD5Sum":"058a31386050f3a6e14429de3ea1372e","Name":"CP066014.zip","Release":"2025-03-07T07:04:48","Revision":"B","SHA1Sum":"73b2d0551a698e2ae01e5e0eb8a8490e9aff94dc","SHA256Sum":"e76a32934d4f623f56bc95e92739897fd6b24930f5a26b582bb09796e592d707","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032c"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP066014","Version":"52.26.3.5487.13-8.0.0.20613240"}]}],"Installation":{"Command":"CP066014.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"ja","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"cn","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"cn","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T03:33:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>PLDMファームウェアアップデートが失敗する可能性がある問題を修正します。この問題は、コントローラー、バックプレーン、およびコントローラーに接続されたドライブで発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"cn"}],"Version":"52.26.3.5487"},{"ReleaseNotes":[{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"cn"}],"Version":"52.26.3.5487"}],"SWKeys":[{"Name":"032C1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0567d9daf4ba4f0b8a156d9768148c71"}]},{"ProductId":"521144c543434ae9b4777bf076b798c5","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d and NS204i-u and NS204i-d Gen11"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、HPE Gen10 PlusブートコントローラーNS204i-p、NS204i-d、およびNS204i-u、およびNS204i-d Gen11のファームウェアを提供します"},{"Lang":"cn","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d and NS204i-u and NS204i-d Gen11"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1483824","DateModified":"2025-09-17T01:09:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/CP068829.xml","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/HPE_NS204i_1.2.14.1018.bin","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068829.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068829.scexe"],"MD5Sum":"f85aeb30230c34e4a0665b4090a673ba","Name":"firmware-9041739931-1.2.14.1018-4.1.x86_64.rpm","Release":"2025-09-17T05:56:27","Revision":"D","SHA1Sum":"bf17326d34d078afc7a9909f754188fa715e4a7b","SHA256Sum":"87613aec9bada5568a3ece569e924f75ffd71a585f3e1223ba328f2b1b86ef62","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"Installation":{"Command":"CP068829.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;the following command:<ul><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;&nbsp;</em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;the following command:<ul><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;&nbsp;</em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;the following command:<ul><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;&nbsp;</em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Flash for Linux(x64) - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"},{"Lang":"ja","Value":"オンラインファームウェアフラッシュfor Linux (x64) - HPE Gen11ブートコントローラーNS204i-u、NS204i-d、およびHPE Gen10 PlusブートコントローラーNS204i-p、NS204i-d"},{"Lang":"cn","Value":"Online Firmware Flash for Linux(x64) - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"2241","SubDev":"02F6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0379","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0380","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","Type":"pci","Ven":"1B4B"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T07:19:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Remove 2 EOL NS204i controllers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>2つのEOL NS204iコントローラーを削除します。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Remove 2 EOL NS204i controllers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.2.14.1018"},{"ReleaseNotes":[{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"cn"}],"Version":"1.2.14.1018"}],"SWKeys":[{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"802cc53b3799481086fb450dc3feb2d4"}]},{"ProductId":"f888ab7160bf41c5a9a5c8dd421e9e88","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v8.55.12. This combo image includes: Boot Code (MFW): 8.55.21.0, UEFI: 4.1.11.2&nbsp;and PXE: 2.0.19. The users will only see the combo image versions in the interactive mode firmware update or while using HPSUM/SPP to update the firmware on the supported adapters.</p>"},{"Lang":"ja","Value":"<p>This software package contains combo image v8.55.12. This combo image includes: Boot Code (MFW): 8.55.21.0, UEFI: 4.1.11.2&nbsp;and PXE: 2.0.19. The users will only see the combo image versions in the interactive mode firmware update or while using HPSUM/SPP to update the firmware on the supported adapters.</p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v8.55.12. This combo image includes: Boot Code (MFW): 8.55.21.0, UEFI: 4.1.11.2&nbsp;and PXE: 2.0.19. The users will only see the combo image versions in the interactive mode firmware update or while using HPSUM/SPP to update the firmware on the supported adapters.</p>"}],"Files":[{"Bytes":"2175045","DateModified":"2024-10-15T21:36:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/CP061237.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/CP061237.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/nic_fw/ql_hp_ah_mbi_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP061237.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP061237.scexe"],"MD5Sum":"73ba45b19522e271adb408a7edcb2ebb","Name":"firmware-nic-qlogic-flq-8.55.12-3.1.x86_64.rpm","Release":"2024-10-16T02:29:29","Revision":"C","SHA1Sum":"58c01c01acc2a32ab7eafad836103837f0558713","SHA256Sum":"cc20972f73044357183a35039caee0db207c20b542ffa35fae68601255f7b671","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059997.txt file.The results of the firmware upgrade are saved&nbsp;in CP059997.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059997.txt file.The results of the firmware upgrade are saved&nbsp;in CP059997.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059997.txt file.The results of the firmware upgrade are saved&nbsp;in CP059997.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-06-20T06:35:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"en"},{"Enhancements":"<p>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</p>","Fixes":"<p>この製品は、iPXEブートを試行しているときのスイッチのPause Flood状態に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"4f7626fc8ae84aa7aa653c82a10b96e2"}]},{"ProductId":"34e01a655b2044b49c3eed7238c1eb30","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するMarvell FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"28252540","DateModified":"2025-03-07T08:15:24","FileList":["/CP065661_BUILD_2.data","/CP065661.vmexe64","/CP065661.vmfile","/CP065661_VMw.zip","/CP065661.xml","/payload.json","/CP065661_VMw.zip/index.xml","/CP065661_VMw.zip/vendor-index.xml","/CP065661_VMw.zip/metadata.zip","/CP065661_VMw.zip/vib20/CP065661/HPE_bootbank_CP065661_8.55.12.2-1OEM.900.0.24580437.vib","/CP065661_VMw.zip/metadata.zip/vendor-index.xml","/CP065661_VMw.zip/metadata.zip/vmware.xml","/CP065661_VMw.zip/metadata.zip/vibs/CP065661-6889978624787216928.xml","/CP065661_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065661_8.55.12.2-1OEM.900.0.24580437.xml"],"MD5Sum":"544d5b805af13b85667607a585cc59c0","Name":"CP065661.zip","Release":"2025-03-07T08:14:11","Revision":"B","SHA1Sum":"9fd69a2f7d5a2b9c1bb57c6ec029bb3631c7a5b6","SHA256Sum":"4d545401f05a022c7c1f4e49529962bda8eabe2bb67d9146ac93ad23d0df9418","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12","VibList":[{"Name":"CP065661","Version":"8.55.12.2-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"ja","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"Marvell FastLinQオンラインファームウェアアップグレードユーティリティ for VMware"},{"Lang":"cn","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-13T08:40:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"en"},{"Enhancements":"<p>この製品は、NPAR有効化オプションをサポートするようになりました。</p>","Fixes":"<ul><li>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</li><li>この製品は、以下のようにネットワークアダプターの過熱の問題に対処します。</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート BaseT QL41132HLRJアダプター<br />HPE Ethernet 10Gb 2ポート BaseT QL41132HQRJ OCP3アダプター</p>","Lang":"ja"},{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"651fca6cd1d24e9787d1480774b0ba84"}]},{"ProductId":"0134d053d49b43b1add04e5a51f6ff18","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"4.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter</td><td>8001778C</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28アダプター</td><td>8001778C</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.2と示されます</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter</td><td>8001778C</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"}],"Files":[{"Bytes":"10520590","DateModified":"2023-07-07T04:16:19","FileList":["HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.HPb","HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.xml","payload.json"],"MD5Sum":"105f1e18f60f8e09901a8d5725cc6631","Name":"HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.fwpkg","Release":"2023-07-19T00:00:00","Revision":"","SHA1Sum":"6b7e92433f5befb184c38a3242a3952589f829f7","SHA256Sum":"7f10e350c6a49e2c35438568d9c725019f956d0fc9bc90061900a23e4ee43e12","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860003"],"TypeOfChange":"1","Version":"4.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-12-29T08:12:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<p>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"cn"}],"Version":"4.20"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<ul><li>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</li><li>この製品は、UMCEが表示される問題に対処します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"cn"}],"Version":"4.20"}],"SWKeys":[{"Name":"INTEL_E810_XXV2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"0bc2bb1c3fca4a838e8c86ad3ec4ff82"}]},{"ProductId":"91453337f2ed4396a7328c9e1b2d5e57","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"15655367","DateModified":"2025-03-06T07:48:55","FileList":["/CP065662_BUILD_15.data","/CP065662.vmexe64","/CP065662.vmfile","/CP065662_VMw.zip","/CP065662.xml","/payload.json","/CP065662_VMw.zip/index.xml","/CP065662_VMw.zip/vendor-index.xml","/CP065662_VMw.zip/metadata.zip","/CP065662_VMw.zip/vib20/CP065662/HPE_bootbank_CP065662_226.1.107000.15-8.0.0.20613240.vib","/CP065662_VMw.zip/metadata.zip/vendor-index.xml","/CP065662_VMw.zip/metadata.zip/vmware.xml","/CP065662_VMw.zip/metadata.zip/vibs/CP065662--3598151471851419397.xml","/CP065662_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065662_226.1.107000.15-8.0.0.20613240.xml"],"MD5Sum":"29eeca764f058ced7ed93692f0faede1","Name":"CP065662.zip","Release":"2025-03-06T07:47:22","Revision":"B","SHA1Sum":"748f5573c5b614f2feef29bc8ce0e7a33a2ca3b3","SHA256Sum":"5174c2c87c1eb546c4ce4d61d6a53bc00779b3ed51a79aaea34a0c90b872ada3","Size":"14MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000","VibList":[{"Name":"CP065662","Version":"226.1.107000.15-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"ja","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティfor VMware"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-13T08:40:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"cn"}],"Version":"226.1.107000"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c1576ebf797a4c3e832004eaa5bd9b88"}]},{"ProductId":"f0c6d80ec7ba4100b11a93d13a983f16","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d and NS204i-u and NS204i-d Gen11"},{"Lang":"ja","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d and NS204i-u and NS204i-d Gen11"},{"Lang":"cn","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d and NS204i-u and NS204i-d Gen11"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for ESXi&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1018<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1018<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; To address known MCTP issue on&nbsp;Intel Gen12/ AMD Turin 2P platforms configured with NS204i device.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for ESXi&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1018<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1018<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; To address known MCTP issue on&nbsp;Intel Gen12/ AMD Turin 2P platforms configured with NS204i device.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for ESXi&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1018<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1018<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; To address known MCTP issue on&nbsp;Intel Gen12/ AMD Turin 2P platforms configured with NS204i device.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2516500","DateModified":"2025-07-23T13:09:15","FileList":["/CP067921_BUILD_2.data","/CP067921.vmexe","/CP067921.vmexe64","/CP067921.vmfile","/CP067921_VMw.zip","/CP067921.xml","/payload.json","/CP067921_VMw.zip/index.xml","/CP067921_VMw.zip/vendor-index.xml","/CP067921_VMw.zip/metadata.zip","/CP067921_VMw.zip/vib20/CP067921/HPE_bootbank_CP067921_1.2.14.1018.2-8.0.0.20613240.vib","/CP067921_VMw.zip/metadata.zip/vendor-index.xml","/CP067921_VMw.zip/metadata.zip/vmware.xml","/CP067921_VMw.zip/metadata.zip/vibs/CP067921--9062839411142639080.xml","/CP067921_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067921_1.2.14.1018.2-8.0.0.20613240.xml"],"MD5Sum":"b9fa9cf62e0784fd5c981c65c08a5728","Name":"CP067921.zip","Release":"2025-07-23T13:08:43","Revision":"C","SHA1Sum":"40778b463426147ff83b874d1f8e6959c9fe90ef","SHA256Sum":"6d0de57c6c51c4ffd10b13a5ed57ea634cd349cc05459dd944f54f37f7af75c8","Size":"2MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018","VibList":[{"Name":"CP067921","Version":"1.2.14.1018.2-8.0.0.20613240"}]}],"Installation":{"Command":"CP067921.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Ensure that CPXXXXXX.vmexe&nbsp; is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPXXXXXX.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file&nbsp;</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Ensure that CPXXXXXX.vmexe&nbsp; is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPXXXXXX.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file&nbsp;</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Ensure that CPXXXXXX.vmexe&nbsp; is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPXXXXXX.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file&nbsp;</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Flash for ESXi - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"},{"Lang":"ja","Value":"Online Firmware Flash for ESXi - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"},{"Lang":"cn","Value":"Online Firmware Flash for ESXi - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"2241","SubDev":"02F6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0379","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0380","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","Type":"pci","Ven":"1B4B"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-23T07:27:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"<p>To address known MCTP issue on&nbsp;Intel Gen12/ AMD Turin 2P platforms configured with NS204i device.</p>","Lang":"en"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"<p>NS204iデバイスで構成されたIntel Gen12/ AMD Turin 2Pプラットフォーム上の既知のMCTP問題に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"<p>To address known MCTP issue on&nbsp;Intel Gen12/ AMD Turin 2P platforms configured with NS204i device.</p>","Lang":"cn"}],"Version":"1.2.14.1018"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Remove 2 EOL NS204i controllers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Remove 2 EOL NS204i controllers.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Remove 2 EOL NS204i controllers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.2.14.1018"}],"SWKeys":[{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ad49b1acb0d4455c86460c727a45f1f9"}]},{"ProductId":"58e30c6460374d34ab64c2a8547dafe2","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-2CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15928086000e","Version":"4.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-2CQDA2 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-2CQDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-2CQDA2 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80017784</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-2CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター</td><td>80017784</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.2と示されます</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80017784</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"}],"Files":[{"Bytes":"10520305","DateModified":"2023-07-07T04:16:04","FileList":["HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.HPb","HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.xml","payload.json"],"MD5Sum":"e3669d465d1556de3acab3346d10f648","Name":"HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.fwpkg","Release":"2023-07-19T00:00:00","Revision":"","SHA1Sum":"ba012c49e28671973d14f4281e4a13fde04ec409","SHA256Sum":"378c3a939e17060e5d877ff5e9a90999d08ea1fc45be853efac52c44500b7958","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-15928086000e"],"TypeOfChange":"1","Version":"4.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-2CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-12-29T08:12:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<p>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"cn"}],"Version":"4.20"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<ul><li>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</li><li>この製品は、UMCEが表示される問題に対処します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"cn"}],"Version":"4.20"}],"SWKeys":[{"Name":"INTEL_E810_2CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"192cd5f22a16489abeb5f1053b7f4187"}]},{"ProductId":"02754226ca24415fbdc877dfe47af242","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>同じファームウェアバージョンの（）内のそのパッケージバージョンには、同じファームウェアバイナリイメージが含まれます。ユーザーは、同じファームウェアバージョンを再フラッシュする必要はありません。</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"9000873","DateModified":"2025-09-17T05:02:58","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/CP068828.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/HPE_luxor_5.61.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068828.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068828.scexe"],"MD5Sum":"1bd81a325737f375db61282835576825","Name":"firmware-smartarray-f7c07bdbbd-5.61-8.1.x86_64.rpm","Release":"2025-09-17T09:46:38","Revision":"H","SHA1Sum":"e46deec6f2d783539a47ce9259e9b0a93d0de335","SHA256Sum":"499fa2cf9da481fc5584320e0997620674ffacf2decb0a2332b31d33ccbe42b9","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652"],"TypeOfChange":"1","Version":"5.61"}],"Installation":{"Command":"CP068828.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>次のコマンドを使用してファームウェアrpmをインストールします：  rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em> <rpm_filename>  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します</li><li>CPXXXXXX.scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-smartarray-f7c07bdbbd-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>./CPXXXXXX.scexe ('/usr/lib/x86_64-linux-gnu/scexe-compat'で実行) (または)</li><li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em> ('.rpm'拡張子の付いていないrpmファイル名) を実行します。</li></ul><p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-f7c07bdbbd-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong><em>追加情報:</em></strong></p><p>ファームウェアrpmパッケージのインストール (rpm -ivh) は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p> </p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li><li>ISOのルートにある launch_sum.sh スクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"16","Minor":"0","Name":"SUSE Linux Enterprise Server 16","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T07:17:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10サポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.61"},{"ReleaseNotes":[{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added SLES16 support</p>","Fixes":"","Lang":"cn"}],"Version":"5.61"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c4d82931ebd84881883ae3cc1108d153"}]},{"ProductId":"306661aaf95b4ed88dcdac14118e89e3","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM957504 100G 1P QSFP56 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E45100","Version":"226.1.107.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains NVM Image version 226.1.107.0&nbsp;with the following firmware versions:</p><p>&nbsp;</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">&nbsp;226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 OCP3 Adapter</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains NVM Image version 226.1.107.0&nbsp;with the following firmware versions:</p><p>&nbsp;</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">&nbsp;226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 OCP3 Adapter</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains NVM Image version 226.1.107.0&nbsp;with the following firmware versions:</p><p>&nbsp;</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">&nbsp;226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 OCP3 Adapter</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"9441129","DateModified":"2024-10-15T01:38:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/CP063802.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/CP063802.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957412A4121HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957412N4120HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957414A4142HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957414N4140HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957416A4162HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957416N4160HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957504A504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957504N504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063802.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063802.scexe"],"MD5Sum":"eb488edbe17aa60f15122d5fac476d52","Name":"firmware-nic-is-bcm-nxe-226.1.107.0-2.1.x86_64.rpm","Release":"2024-10-15T06:32:07","Revision":"B","SHA1Sum":"d747df79fc9050fa5f002334b73a4d21cdcd4358","SHA256Sum":"5d0c0f9a58e5f558b7c8ee141d29d306f8396352c5fae26b9f4f74ffc6c40f62","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599","a6b1a447-382a-5a4f-14E4-175114E45100"],"TypeOfChange":"1","Version":"226.1.107.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CP056670.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP062142.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CP062142<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CP062142.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CP056670.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP062142.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CP062142<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CP062142.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CP056670.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP062142.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CP062142<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CP062142.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"5100","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e45100","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-07T05:02:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"cn"}],"Version":"226.1.107.0"}],"SWKeys":[{"Name":"IS_BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"U70","Model":"HPE ProLiant DL380a Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"0fe8c4c618054fe0bf5f8d2fd314f3f5"}]},{"ProductId":"2f647e8bf5e8465593bc96dbee2aa1ad","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The x64 Smart Component provides firmware for HPE Gen11 Boot Controller NS204i-u, NS204i-d and Gen10 Plus Boot Controller NS204i-p, NS204i-d"},{"Lang":"ja","Value":"The x64 Smart Component provides firmware for HPE Gen11 Boot Controller NS204i-u, NS204i-d and Gen10 Plus Boot Controller NS204i-p, NS204i-d"},{"Lang":"cn","Value":"The x64 Smart Component provides firmware for HPE Gen11 Boot Controller NS204i-u, NS204i-d and Gen10 Plus Boot Controller NS204i-p, NS204i-d"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"782276","DateModified":"2025-09-16T09:54:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/CP067804.xml","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/HPE_NS204i_1.2.14.1018.bin","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067804.scexe","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067804.scexe"],"MD5Sum":"25997f971e4e1a2673bcbfc600247229","Name":"firmware-9041739931_1.2.14.1018-1.1_amd64.deb","Release":"2025-09-16T14:48:37","Revision":"","SHA1Sum":"6f6698485f32f31fb46d6f77a5d55ec32c42ec81","SHA256Sum":"cfdba5e3cdf3d44a140382100141d4ed7b7818665d223897465e7d38357788b4","Size":"763KB","TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"Installation":{"Command":"CP067804.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Ubuntu&nbsp;operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The actual name of the &#39;firmware-xxxxxxxxxx_x.x.xx.xxxx.1.1*&#39; folder is based on the version of the&nbsp;deb installed in the first step above</li><li>To install firmware,&nbsp;<ul><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-xxxxxxxxxx_x.x.xx.xxxx.1.1*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo apt purge&nbsp;firmware-xxxxxxxxxx, which is the deb filename without the &#39;.deb&#39; extension</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Ubuntu&nbsp;operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The actual name of the &#39;firmware-xxxxxxxxxx_x.x.xx.xxxx.1.1*&#39; folder is based on the version of the&nbsp;deb installed in the first step above</li><li>To install firmware,&nbsp;<ul><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-xxxxxxxxxx_x.x.xx.xxxx.1.1*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo apt purge&nbsp;firmware-xxxxxxxxxx, which is the deb filename without the &#39;.deb&#39; extension</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Ubuntu&nbsp;operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The actual name of the &#39;firmware-xxxxxxxxxx_x.x.xx.xxxx.1.1*&#39; folder is based on the version of the&nbsp;deb installed in the first step above</li><li>To install firmware,&nbsp;<ul><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-xxxxxxxxxx_x.x.xx.xxxx.1.1*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo apt purge&nbsp;firmware-xxxxxxxxxx, which is the deb filename without the &#39;.deb&#39; extension</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Flash for Ubuntu - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"},{"Lang":"ja","Value":"Online Firmware Flash for Ubuntu - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"},{"Lang":"cn","Value":"Online Firmware Flash for Ubuntu - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"2241","SubDev":"030E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"02F6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0379","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0380","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","Type":"pci","Ven":"1B4B"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"26","Minor":"04","Name":"Ubuntu 26.04 LTS","Platform":"ubuntu2604","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-11T05:34:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>.</p>","Fixes":"","Lang":"cn"}],"Version":"1.2.14.1018"}],"SWKeys":[{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7745ced637364082a3707b93a760c88b"}]},{"ProductId":"955cffa0d4fe4b76923c0ea7afeca0bf","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"4.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA4 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td><td>80017789</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28アダプター</td><td>80017789</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.2と示されます</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td><td>80017789</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"}],"Files":[{"Bytes":"10520366","DateModified":"2023-07-07T04:26:06","FileList":["HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.HPb","HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.xml","payload.json"],"MD5Sum":"4db7efb5eb02efe23c48e9708b247250","Name":"HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.fwpkg","Release":"2023-07-19T00:00:00","Revision":"","SHA1Sum":"77bcc81598acc820859e00b84ec36faf529522a3","SHA256Sum":"b2beae73117355f6488f71a02518a5c2bb333ebaf7122a0dd41ecfbf814d2b58","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159380860005"],"TypeOfChange":"1","Version":"4.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-12-29T08:12:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<p>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"cn"}],"Version":"4.20"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<ul><li>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</li><li>この製品は、UMCEが表示される問題に対処します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"cn"}],"Version":"4.20"}],"SWKeys":[{"Name":"INTEL_E810_XXV4_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"d625d75d2edc4dd09520c151c1346edf"}]},{"ProductId":"5ace706167bb418f8ac30077c43e3171","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、P204i-c、E208i-p、E208e-p、E208i-a、E208i-c、P816i-a、およびP416ie-m SR Gen10"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>同じファームウェアバージョンの（）内のそのパッケージバージョンには、同じファームウェアバイナリイメージが含まれます。ユーザーは、同じファームウェアバージョンを再フラッシュする必要はありません。</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"7250920","DateModified":"2025-11-14T02:15:19","FileList":["cp067918.xml","cpqsetup.exe","HPE_luxor_5.61.bin.fw","payload.json","setup.dll"],"MD5Sum":"339973527d058e286b71e92dfbae4075","Name":"cp067918.exe","Release":"2025-11-14T02:05:28","Revision":"G","SHA1Sum":"ebbbdc2856035c4c18e359bc04a94ec55c42a209","SHA256Sum":"cb79175d4be1ede24cc6d2d728c6ebba68e6dfd4bb45c2a64095c4ae77ed56f7","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652"],"TypeOfChange":"1","Version":"5.61"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>HPE Smart Update Managerを使用するには、</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>から以下の手順に従ってください:</strong></strong></p><ul><li>ディレクトリ\\SPP20xxxxx\\packagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10"},{"Lang":"ja","Value":"Windows (x64) 用オンラインROMフラッシュコンポーネント - HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、P204i-c、E208i-p、E208e-p、E208i-a、E208i-c、P816i-a、およびP416ie-m SR Gen10"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-23T06:26:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support new OS&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>新しいOS Azure Stack HCI 23H2をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new OS&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"cn"}],"Version":"5.61"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Azure Local 24H2 OS support.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.61"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"c1becc9ec194435c8ad7529bca5e3040"}]},{"ProductId":"dc41774861a945f28d388059e656b2ca","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"4.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-CQDA2 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td><td>80017783</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2ポートQSFP28 OCP3アダプター</td><td>80017783</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.2と示されます</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td><td>80017783</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"}],"Files":[{"Bytes":"10520477","DateModified":"2023-07-07T04:15:53","FileList":["HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.HPb","HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.xml","payload.json"],"MD5Sum":"0a921e110e2a9871787debebc5a37564","Name":"HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.fwpkg","Release":"2023-07-19T00:00:00","Revision":"","SHA1Sum":"93879152515d558b14687a6a16f59a5c0893ec0d","SHA256Sum":"8b4a3f8959ffea3feb8881faf445daf349f93179dcd65fa78c98ad5abd1566b5","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860006"],"TypeOfChange":"1","Version":"4.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-CQDA2 Ethernet 100Gb 2ポートQSFP28 OCP3アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-12-29T08:12:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<p>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"cn"}],"Version":"4.20"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<ul><li>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</li><li>この製品は、UMCEが表示される問題に対処します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"cn"}],"Version":"4.20"}],"SWKeys":[{"Name":"INTEL_E810_CQ2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"337ecb0ac1f2420ca160d42df14b3a27"}]},{"ProductId":"5b5ee0e363994b83af6394dce2b49314","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"この x64 Smartコンポーネントは、次のストレージコントローラー用のファームウェアを提供します。 HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10 コントローラー"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;5.61<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;5.61<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers</p><p>&nbsp;</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;5.61<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; None</p><p>&nbsp;</p><p><strong>&nbsp;Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p>&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"7293244","DateModified":"2025-09-15T23:02:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-1.1/CP068816.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-1.1/HPE_luxor_5.61.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068816.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068816.scexe"],"MD5Sum":"2604c7be719d1561c0a021ba6eb2d88d","Name":"firmware-smartarray-98373e8f27_5.61-1.1_amd64.deb","Release":"2025-09-16T03:47:18","Revision":"","SHA1Sum":"07ee18d7ec16a72cf53ca42a1d700bb002adad2e","SHA256Sum":"c92d9c48c107162e0c8b5514883cbe55fd5a0c4d5684c4adeeee367b730da757","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"5.61"}],"Installation":{"Command":"CP068816.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Ubuntu&nbsp;operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp; </em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Ubuntu&nbsp;operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp; </em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Ubuntu&nbsp;operating system on target server:</strong></p><p>&nbsp;</p><p><strong><em>Updating firmware with deb installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware deb using the command: sudo dpkg -i<em>&nbsp;&lt;deb_filename&gt;.&nbsp; </em>This extracts the contents of the deb to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder.&nbsp;The actual name of the &#39;firmware-smartarray-xxxxxxxxxx-*&#39; folder is based on the version of the&nbsp;deb installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following command:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-xxxxxxxxxx-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the deb, run the command: sudo dpkg -P&nbsp;<em>&lt;deb_package_name&gt;</em>, which is the deb filename without the &#39;.deb&#39; extension</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware deb package (sudo dpkg -i) does not update the firmware.&nbsp;&nbsp;It merely extracts the deb content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Ubuntu - HPE SmartアレイP408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10コントローラー"},{"Lang":"cn","Value":"Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"26","Minor":"04","Name":"Ubuntu 26.04 LTS","Platform":"ubuntu2604","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-10-16T02:21:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Prerequisite version</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Prerequisite version</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Prerequisite version</p>","Fixes":"","Lang":"cn"}],"Version":"5.61"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"28cfa08172ce40c19d73e4f60e0aa71c"}]},{"ProductId":"97376eb681cc4681a46dc573b80df4a8","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR416i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.26.3.5487"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The ESXi Smart Component provides controller firmware for HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ESXi Smartコンポーネントは、HPE MR416i-p Gen10 Plusトライモードコントローラー用のコントローラーファームウェアを提供します"},{"Lang":"cn","Value":"The ESXi Smart Component provides controller firmware for HPE MR416i-p Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>HPEMR416i-p Online FW Update with OS command option.</p>"},{"Lang":"ja","Value":"<p>OSコマンドオプションを使用したHPEMR416i-pオンラインFWアップデート。</p>"},{"Lang":"cn","Value":"<p>HPEMR416i-p Online FW Update with OS command option.</p>"}],"Files":[{"Bytes":"13070191","DateModified":"2025-03-07T07:19:13","FileList":["/CP066017_BUILD_6.data","/CP066017.vmexe64","/CP066017.vmfile","/CP066017_VMw.zip","/CP066017.xml","/payload.json","/CP066017_VMw.zip/index.xml","/CP066017_VMw.zip/vendor-index.xml","/CP066017_VMw.zip/metadata.zip","/CP066017_VMw.zip/vib20/CP066017/HPE_bootbank_CP066017_52.26.3.5487.6-8.0.0.20613240.vib","/CP066017_VMw.zip/metadata.zip/vendor-index.xml","/CP066017_VMw.zip/metadata.zip/vmware.xml","/CP066017_VMw.zip/metadata.zip/vibs/CP066017--8757306290411093994.xml","/CP066017_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066017_52.26.3.5487.6-8.0.0.20613240.xml"],"MD5Sum":"fcc07bd86e54364cb595563406fd4e08","Name":"CP066017.zip","Release":"2025-03-07T07:18:36","Revision":"B","SHA1Sum":"035b5e52dc0c49364f751414b0f5a08f44808f22","SHA256Sum":"a915d75da1b381c550ef174f26c5cb5569d617fb46baf3b3f7b74330f014eb61","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e215900293"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP066017","Version":"52.26.3.5487.6-8.0.0.20613240"}]}],"Installation":{"Command":"CP066017.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"ja","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"cn","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"Lang":"cn","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-p Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T03:33:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>PLDMファームウェアアップデートが失敗する可能性がある問題を修正します。この問題は、コントローラー、バックプレーン、およびコントローラーに接続されたドライブで発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"cn"}],"Version":"52.26.3.5487"},{"ReleaseNotes":[{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"cn"}],"Version":"52.26.3.5487"}],"SWKeys":[{"Name":"02931590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1b93ff065b584fa0a120fc739b088ef5"}]},{"ProductId":"cdec784418854d66b9abfcfb18b3f4ef","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2019 and Windows Server 2022."},{"Lang":"ja","Value":"このパッケージには、Microsoft Windows Server 2019とWindows Server 2022で動作するMarvell  FastLinQ 10/25/50 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"3156736","DateModified":"2025-11-20T08:06:20","FileList":["cp069754.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_ah_mbi_open_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"3b950fa11db4fde3b907843c69d6c76e","Name":"cp069754.exe","Release":"2025-11-20T07:58:05","Revision":"D","SHA1Sum":"3c19f6f6a393d21c224c378f7da3d8e2665f1fec","SHA256Sum":"e86be90d623a7b913d77af5ac79ae6d5be70c848086592cb06e31c8d9b00d20f","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"Marvell FastLinQオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-20T06:55:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"en"},{"Enhancements":"<p>この製品は、NPAR有効化オプションをサポートするようになりました。</p>","Fixes":"<ul><li>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</li><li>この製品は、以下のようにネットワークアダプターの過熱の問題に対処します。</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート BaseT QL41132HLRJアダプター<br />HPE Ethernet 10Gb 2ポート BaseT QL41132HQRJ OCP3アダプター</p>","Lang":"ja"},{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"5d468adc62504bb6a685fd6edf91e344"}]},{"ProductId":"02b2a9a0b28a4ed5b031b302593f96b6","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains NVM Image version 226.1.107000&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains NVM Image version 226.1.107000&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains NVM Image version 226.1.107000&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"}],"Files":[{"Bytes":"1342884","DateModified":"2025-09-15T20:30:25","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/CP068813.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/CP068813.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068813.scexe","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068813.scexe"],"MD5Sum":"9a2dd48ab3e0856669b98ee24ee35c28","Name":"firmware-nic-bcm-nxe_226.1.107000-1.1_amd64.deb","Release":"2025-09-16T01:24:49","Revision":"","SHA1Sum":"a337929c31c9a16771833fba8c4a03d6b0ee7d8d","SHA256Sum":"ab98326d2081e30c5fe3f59a458394f7fd629569784041fd72b5214ed4d1adf8","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T00:56:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"cn"}],"Version":"226.1.107000"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"fb1b62b98ea044789fa1f3c146cb1153"}]},{"ProductId":"6a4f9209b5474891beaf50886f41470e","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4T adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15938086000e","Version":"4.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4T Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA4T Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4T Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter for HPE</td><td>8001778B</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 MCLKアダプターfor HPE</td><td>8001778B</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.2と示されます</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter for HPE</td><td>8001778B</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"}],"Files":[{"Bytes":"10518151","DateModified":"2023-07-07T08:08:15","FileList":["HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.HPb","HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.xml","payload.json"],"MD5Sum":"80ca5e2c190672cc834fd91498837ab7","Name":"HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.fwpkg","Release":"2023-07-19T00:00:00","Revision":"","SHA1Sum":"54cd7f3128875f7856d8443d44c50bc94ffb32a0","SHA256Sum":"3c1207be8dc30c201ec165e7508b8b9382dd960c3e447590051eb9fad52a0ff1","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000e"],"TypeOfChange":"1","Version":"4.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter "},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 MCLKアダプター "},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-12-29T08:12:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<p>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"cn"}],"Version":"4.20"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<ul><li>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</li><li>この製品は、UMCEが表示される問題に対処します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"cn"}],"Version":"4.20"}],"SWKeys":[{"Name":"INTEL_E810_XXV4T_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"b2fda4504c8e4e88967534823eb60069"}]},{"ProductId":"03731a36570c4baca7e553d9af4e7172","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR416i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.26.3.5487"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The ESXi Smart Component provides controller firmware for HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ESXi Smartコンポーネントは、HPE MR416i-a Gen10 Plusトライモードコントローラー用のコントローラーファームウェアを提供します"},{"Lang":"cn","Value":"The ESXi Smart Component provides controller firmware for HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>HPEMR416i-a&nbsp;Online FW Update with OS command option.</p>"},{"Lang":"ja","Value":"<p>OSコマンドオプションを使用したHPEMR416i-aオンラインFWアップデート。</p>"},{"Lang":"cn","Value":"<p>HPEMR416i-a&nbsp;Online FW Update with OS command option.</p>"}],"Files":[{"Bytes":"13070512","DateModified":"2025-03-07T08:11:23","FileList":["/CP066016_BUILD_8.data","/CP066016.vmexe64","/CP066016.vmfile","/CP066016_VMw.zip","/CP066016.xml","/payload.json","/CP066016_VMw.zip/index.xml","/CP066016_VMw.zip/vendor-index.xml","/CP066016_VMw.zip/metadata.zip","/CP066016_VMw.zip/vib20/CP066016/HPE_bootbank_CP066016_52.26.3.5487.8-8.0.0.20613240.vib","/CP066016_VMw.zip/metadata.zip/vendor-index.xml","/CP066016_VMw.zip/metadata.zip/vmware.xml","/CP066016_VMw.zip/metadata.zip/vibs/CP066016--1627405003484883866.xml","/CP066016_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066016_52.26.3.5487.8-8.0.0.20613240.xml"],"MD5Sum":"9d5ef52f03725b0dcd8a7b78f047bf95","Name":"CP066016.zip","Release":"2025-03-07T08:10:52","Revision":"B","SHA1Sum":"a7366d7e21e6cb4417cd41c36339f66e5b471dc2","SHA256Sum":"5614bc78ccf8c4efae90e02be2207b6bbadc33cd6d5c7934999fbe8d2ab9a241","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032a"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP066016","Version":"52.26.3.5487.8-8.0.0.20613240"}]}],"Installation":{"Command":"CP066016.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p><p>&nbsp;</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p><p>&nbsp;</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p><p>&nbsp;</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"cn","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T03:33:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>PLDMファームウェアアップデートが失敗する可能性がある問題を修正します。この問題は、コントローラー、バックプレーン、およびコントローラーに接続されたドライブで発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"cn"}],"Version":"52.26.3.5487"},{"ReleaseNotes":[{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"cn"}],"Version":"52.26.3.5487"}],"SWKeys":[{"Name":"032A1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6b2e85bef481441482ee2a1e938fdc49"}]},{"ProductId":"602ca61a8c5c4bb59d43629712dde7fb","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0"},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"19482573","DateModified":"2025-03-07T08:15:15","FileList":["/CP065663_BUILD_4.data","/CP065663.vmexe64","/CP065663.vmfile","/CP065663_VMw.zip","/CP065663.xml","/payload.json","/CP065663_VMw.zip/index.xml","/CP065663_VMw.zip/vendor-index.xml","/CP065663_VMw.zip/metadata.zip","/CP065663_VMw.zip/vib20/CP065663/HPE_bootbank_CP065663_226.1.107.0.4-1OEM.900.0.24580437.vib","/CP065663_VMw.zip/metadata.zip/vendor-index.xml","/CP065663_VMw.zip/metadata.zip/vmware.xml","/CP065663_VMw.zip/metadata.zip/vibs/CP065663-812639207484415047.xml","/CP065663_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065663_226.1.107.0.4-1OEM.900.0.24580437.xml"],"MD5Sum":"c9d981cbef91da2f5996fafe2bbbcbc2","Name":"CP065663.zip","Release":"2025-03-07T08:13:45","Revision":"B","SHA1Sum":"822aabb53f6aab1d4577df8b8aa4fdbc5b7fcf31","SHA256Sum":"e9b347f13ccc9fde802e9e3d3a49f36d1b6f96d342af7e6ce474921c6b0a760a","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599"],"TypeOfChange":"1","Version":"226.1.107.0","VibList":[{"Name":"CP065663","Version":"226.1.107.0.4-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"ja","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-13T08:40:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"cn"}],"Version":"226.1.107.0"}],"SWKeys":[{"Name":"IS_BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0602e754bc4c46f5a3f50af806cd01ac"}]},{"ProductId":"f3f8a4081d78499e9a2dd9c8d9fb4059","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"4.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-CQDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80017785</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター</td><td>80017785</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.2と示されます</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80017785</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"}],"Files":[{"Bytes":"10520276","DateModified":"2023-07-10T02:31:01","FileList":["HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.HPb","HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.xml","payload.json"],"MD5Sum":"5ca6b5ab7cf61ffec7befddbb236bd53","Name":"HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.fwpkg","Release":"2023-07-19T00:00:00","Revision":"","SHA1Sum":"b4692fa59852868b966be1f76a565d1e75d9d137","SHA256Sum":"221449becbc98c0f50e46c46e01eaf80b091db8aab446310b581c410a58859bd","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860002"],"TypeOfChange":"1","Version":"4.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-12-29T08:12:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<p>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"cn"}],"Version":"4.20"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<ul><li>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</li><li>この製品は、UMCEが表示される問題に対処します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"cn"}],"Version":"4.20"}],"SWKeys":[{"Name":"INTEL_E810_CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"6d9c82c72d0a40b5b4987b97c622bce2"}]},{"ProductId":"784734de08894560b84fe3fe282166e8","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM957504 100G 1P QSFP56 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E45100","Version":"226.1.107.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains NVM Image version 226.1.107.0&nbsp;with the following firmware versions:</p><p>&nbsp;</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">&nbsp;226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 OCP3 Adapter</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains NVM Image version 226.1.107.0&nbsp;with the following firmware versions:</p><p>&nbsp;</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">&nbsp;226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 OCP3 Adapter</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains NVM Image version 226.1.107.0&nbsp;with the following firmware versions:</p><p>&nbsp;</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">&nbsp;226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 OCP3 Adapter</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"2284000","DateModified":"2025-09-15T22:34:46","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/CP068817.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/CP068817.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957412A4121HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957412N4120HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957414A4142HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957414N4140HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957416A4162HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957416N4160HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957504A504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957504N504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068817.scexe","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068817.scexe"],"MD5Sum":"0b20213b984977c36a253313c4b2d364","Name":"firmware-nic-is-bcm-nxe_226.1.107.0-1.1_amd64.deb","Release":"2025-09-16T03:28:54","Revision":"","SHA1Sum":"38daa0d42ae3596351d284794b8152ac965dc06d","SHA256Sum":"007a09041172265d728185bfcda150fdce63ec3dda2d36b84f4a8073ccdacf7d","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599","a6b1a447-382a-5a4f-14E4-175114E45100"],"TypeOfChange":"1","Version":"226.1.107.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CP056670.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP062142.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CP062142<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CP062142.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CP056670.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP062142.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CP062142<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CP062142.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CP056670.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP062142.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CP062142<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CP062142.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"5100","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e45100","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"24","Minor":"04","Name":"Ubuntu 24.04 LTS","Platform":"ubuntu2404","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-10-16T02:58:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"cn"}],"Version":"226.1.107.0"}],"SWKeys":[{"Name":"IS_BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"5d7180125efc4487bd07cf626af64faa"}]},{"ProductId":"8aa4f1e30dfc4417885cea85b551314e","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_148.bin","InstallDurationSec":150,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides updated iLO firmware that can be installed directly on supported Linux Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HP Smart Update Manager."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるLinuxオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、HP Smart Update Managerと一緒に使用することが出来ます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><a href=\"http://www.hpe.com/info/ilo-docs\" rel=\"noopener noreferrer\" target=\"_blank\">http://www.hpe.com/info/ilo-docs</a><br />Select your lights-out product, then support &amp; documents, then manuals.</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p> </p><p>また、『iLO 5ユーザーガイド』および『Lights-Outスクリプティングガイド』も下記のリンクから入手できます：<br /><a href=\"http://www.hpe.com/info/ilo-docs\" rel=\"noopener noreferrer\" target=\"_blank\">http://www.hpe.com/info/ilo-docs</a><br />ご使用のLights-Out製品、サポート&ドキュメント、ドキュメントの順に選択します。</p><ul><li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />オンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li></ul>"}],"Files":[{"Bytes":"17467512","DateModified":"2024-10-24T02:11:56","FileList":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/CP064211.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/ilo5_148.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064211.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064211.scexe"],"MD5Sum":"555d32c65e31b4b84e634de11acef16a","Name":"firmware-ilo5-1.48-3.1.x86_64.rpm","Release":"2024-10-24T07:04:16","Revision":"c","SHA1Sum":"bc216f1155617115f1e55e1dc6c4b33166dd9b33","SHA256Sum":"10441a45116e8b919188508abe8a3b763c76d189680cf0490bcdf0b855151a17","Size":"16MB","TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"1","Version":"1.48"}],"Installation":{"Command":"sh CP0XXXXX.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":150,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Supplemental updates for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><p>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.<br />Place the desired components to be updated in the directory, \\packages on the USB key.<br />Update the firmware and software in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。</p><p>サポートされるProLiantサーバーおよびオプションのためのサプリメンタルアップデートは、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。<br />アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。<br />通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5120"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86)","Platform":"red_hat_enterprise_linux_x86","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Workstation (x86)","Platform":"red_hat_enterprise_linux_client_x86","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","Platform":"red_hat_enterprise_linux_client_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (x86)","Platform":"suse_linux_enterprise_server_x86","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-23T12:30:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>None</p>","Fixes":"<p>Enabling installation in OS FIPS mode.</p>","Lang":"en"},{"Enhancements":"<p>なし</p>","Fixes":"<p>OS FIPSモードでのインストールを有効にします。</p>","Lang":"ja"},{"Enhancements":"<p>None</p>","Fixes":"<p>Enabling installation in OS FIPS mode.</p>","Lang":"cn"}],"Version":"1.48"},{"ReleaseNotes":[{"Enhancements":"<p>None</p>","Fixes":"<p>Built with new&nbsp;RPM signing key</p>","Lang":"en"},{"Enhancements":"<p>None</p>","Fixes":"<p>Built with new&nbsp;RPM signing key</p>","Lang":"ja"},{"Enhancements":"<p>None</p>","Fixes":"<p>Built with new&nbsp;RPM signing key</p>","Lang":"cn"}],"Version":"1.48"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"705315077b1e4ba986471688e76a38e4"}]},{"ProductId":"39f751214cc74d66b0930165bf7cce77","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するMarvell FastLinQ Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v8.55.12.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.55.22.0, and UEFI: 6.1.8.2.</p>"},{"Lang":"ja","Value":"<p>This software package contains combo image v8.55.12.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.55.22.0, and UEFI: 6.1.8.2.</p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v8.55.12.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.55.22.0, and UEFI: 6.1.8.2.</p>"}],"Files":[{"Bytes":"2219909","DateModified":"2024-10-15T21:35:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/CP061236.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/CP061236.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/nic_fw/ql_ah_mbi_open_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP061236.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP061236.scexe"],"MD5Sum":"2b0e832e4cbf1b2a5419e09c10fa968e","Name":"firmware-nic-is-marvell-flq-8.55.12-3.1.x86_64.rpm","Release":"2024-10-16T02:28:54","Revision":"C","SHA1Sum":"bc71c2e0a764b827df29c5a4628c5d5a30d140cb","SHA256Sum":"92bee08435d7cd4f24fbb8e665b31f445c240e51ce21aef953567a9c10fd2d29","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059998.txt file.The results of the firmware upgrade are saved&nbsp;in CP059998.log at &quot;/var/cpq/&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059998.txt file.The results of the firmware upgrade are saved&nbsp;in CP059998.log at &quot;/var/cpq/&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059998.txt file.The results of the firmware upgrade are saved&nbsp;in CP059998.log at &quot;/var/cpq/&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"Marvell FastLinQオンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-06-20T06:34:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"en"},{"Enhancements":"<p>この製品は、NPAR有効化オプションをサポートするようになりました。</p>","Fixes":"<ul><li>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</li><li>この製品は、以下のようにネットワークアダプターの過熱の問題に対処します。</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート BaseT QL41132HLRJアダプター<br />HPE Ethernet 10Gb 2ポート BaseT QL41132HQRJ OCP3アダプター</p>","Lang":"ja"},{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"df0d2e84414545c18a181d95d2115f5e"}]},{"ProductId":"4f319faf890642fc80a3d8719760c121","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"},{"Lang":"ja","Value":"このスマートコンポーネントは、次のストレージコントローラー用のファームウェアを提供します：HPE SmartアレイP816i-a、P416ie-m、P408i-p、P408e-p、P408i-a、P408i-c、P204i-c、E208i-p、E208e-p、E208i-a、P208i-c SR Gen10"},{"Lang":"cn","Value":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>同じファームウェアバージョンの（）内のそのパッケージバージョンには、同じファームウェアバイナリイメージが含まれます。ユーザーは、同じファームウェアバージョンを再フラッシュする必要はありません。</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"24514576","DateModified":"2025-03-07T06:30:41","FileList":["/CP064739_BUILD_15.data","/CP064739.vmexe64","/CP064739.vmfile","/CP064739_VMw.zip","/CP064739.xml","/payload.json","/CP064739_VMw.zip/index.xml","/CP064739_VMw.zip/vendor-index.xml","/CP064739_VMw.zip/metadata.zip","/CP064739_VMw.zip/vib20/CP064739/HPE_bootbank_CP064739_5.61.15-8.0.0.20613240.vib","/CP064739_VMw.zip/metadata.zip/vendor-index.xml","/CP064739_VMw.zip/metadata.zip/vmware.xml","/CP064739_VMw.zip/metadata.zip/vibs/CP064739-7636149840308960091.xml","/CP064739_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064739_5.61.15-8.0.0.20613240.xml"],"MD5Sum":"e0d18832300f902548c6e0f6655f960e","Name":"CP064739.zip","Release":"2025-03-17T00:00:00","Revision":"E","SHA1Sum":"d90b303a0a1313afb9128545c7290d26ca7b0db3","SHA256Sum":"9b608c26c3f5f8b882f53a813593db78d418ac45f4a6b82c03dd316f8a43276d","Size":"23MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654"],"TypeOfChange":"1","Version":"5.61","VibList":[{"Name":"CP064739","Version":"5.61.15-8.0.0.20613240"}]}],"Installation":{"Command":"CP064739.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=c03190790\">Service Pack for ProLiant Quick Start Guide</a></p><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=c03190790\">Service Pack for ProLiant Quick Start Guide</a></p><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"cn","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=c03190790\">Service Pack for ProLiant Quick Start Guide</a></p><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"},{"Lang":"ja","Value":"VMware ESXi用オンラインROMフラッシュコンポーネント - HPE SmartアレイP816i-a、P416ie-m、P408i-p、P408e-p、P408i-a、P408i-c、P204i-c、E208i-p、E208e-p、E208i-a、P208i-c SR Gen10"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-09-28T05:54:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added ESXi9.0 support.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added ESXi9.0 support.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.61"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added ESXi9.0 support.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ESXi 9.0のサポートを追加しました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added ESXi9.0 support.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.61"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cf6604fda4654cfeb6cf2035f65f72b4"}]},{"ProductId":"149ff2208f3a4a13b7c145a5ab625b8a","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d and NS204i-u, NS204i-d Gen11"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、HPE Gen10 PlusブートコントローラーNS204i-p、NS204i-d、およびNS204i-u、NS204i-d Gen11のファームウェアを提供します"},{"Lang":"cn","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d and NS204i-u, NS204i-d Gen11"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1774104","DateModified":"2025-11-18T07:24:14","FileList":["cp069579.xml","cpqsetup.exe","HPE_NS204i_1.2.14.1018.bin","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"8ea1c84c2f914b93908bd0617d6ebf4b","Name":"cp069579.exe","Release":"2025-11-18T07:22:03","Revision":"C","SHA1Sum":"e7cb59b4f22da4c146aada4422c107f7a8b2b797","SHA256Sum":"aefb8493fd2f449db2758db28f2c13c76ffe8f7901a4c4ae13acbefbe4b6b137","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>HPE Smart Update Managerを使用するには、</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>から以下の手順に従ってください:</strong></strong></p><ul><li>ディレクトリ\\SPP20xxxxx\\packagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Flash for Windows - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"},{"Lang":"ja","Value":"オンラインファームウェアフラッシュfor Windows - HPE Gen11ブートコントローラーNS204i-u、NS204i-d、およびHPE Gen10 PlusブートコントローラーNS204i-p、NS204i-d"},{"Lang":"cn","Value":"Online Firmware Flash for Windows - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"2241","SubDev":"02F6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0379","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0380","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","Type":"pci","Ven":"1B4B"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"26100","MinimumBuild":"26100","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-14T02:21:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new OS&nbsp;Azure Local 24H2.</li><li>Remove 2 EOL NS204i controllers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>新しいOS Azure Local 24H2をサポートします。</li><li>2つのEOL NS204iコントローラーを削除します。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new OS&nbsp;Azure Local 24H2.</li><li>Remove 2 EOL NS204i controllers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.2.14.1018"},{"ReleaseNotes":[{"Enhancements":"<p>Fix build tool certification issue.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Fix build tool certification issue.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Fix build tool certification issue.</p>","Fixes":"","Lang":"cn"}],"Version":"1.2.14.1018"}],"SWKeys":[{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"bc87722faee84be4a9d5069381996238"}]},{"ProductId":"9b49e335f12147b9aba4f47e0e39b392","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Windows Server 2019 and Windows Server 2022."},{"Lang":"ja","Value":"このパッケージには、Windows Server 2019およびWindows Server 2022で動作するHPE ProLiant Broadcom NetXtreme-E Ethernet NICのブートコード、PXE、UMP、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9909976","DateModified":"2025-11-20T07:45:14","FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp069751.xml","cpqsetup.exe","FW/","FW/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","FW/535T-2x10-14E4-16D8-1590-020C.PKG","FW/536I-2x10-14E4-16D6-1590-0230.pkg","FW/537SFP-2x10-14E4-16D7-1590-02C3.pkg","FW/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","FW/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","FW/631SFP28-2x25-14E4-16D7-1590-020E.PKG","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"8ed200db49e527257adb7a8ab1de3ae5","Name":"cp069751.exe","Release":"2025-11-20T07:37:12","Revision":"C","SHA1Sum":"de44dd46826c0149e22f30684eb9dd42a32f0b64","SHA256Sum":"ba9f333a627b6efb0ad6dc0128dfbf4380f38040314ff1e3e68f2ee3b032e447","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EE15900212"],"TypeOfChange":"1","Version":"226.1.107000"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティfor Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-20T06:55:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>add&nbsp;Azure Stack HCI OS supported</p>","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"en"},{"Enhancements":"<p>Azure Stack HCI OSのサポートを追加しました</p>","Fixes":"<ul><li>この製品は、プラットフォーム側からの一部のFRU読み取りコマンドに対するNC-SIパススルーアルゴリズムに対処しました。</li><li>この製品は、9600ジャンボサイズを超えるパケット受信時のパケット転送ルールに対処しました。</li><li>この製品は、リンク速度の変更後のFreeBSD OSでのリンク障害に対処しました。</li><li>この製品は、スイッチのオンとオフを実行するときのSRIOVのVFの起動の失敗に対処しました。</li><li>この製品は、128台のVMで高負荷がかかっているときにアダプターが応答しない問題に対処しました。</li><li>この製品は、BMCを使用したPLDMセンサー監視のステータスレポートに対処しました。</li><li>この製品は、リンクダウンまたはウォームブート後のリンクフラップに対処しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>add&nbsp;Azure Stack HCI OS supported</p>","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"cn"}],"Version":"226.1.107000"}],"SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"21283c052dce4f2493e243981fbd009f"}]},{"ProductId":"fbb53cf22a594dbb99b8c7f89e562124","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"4.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA2 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</td><td>80017787</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28 OCP3アダプター</td><td>80017787</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.2と示されます</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</td><td>80017787</td><td>1.3346.0</td><td>4.20</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.2</p>"}],"Files":[{"Bytes":"10520593","DateModified":"2023-07-07T04:26:18","FileList":["HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.HPb","HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.xml","payload.json"],"MD5Sum":"88b4da09e1b7a7c81a158852d06d4369","Name":"HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.fwpkg","Release":"2023-07-19T00:00:00","Revision":"","SHA1Sum":"8340791f033723a38702b6ab59c68f3522181df9","SHA256Sum":"76a117c2c99fdda0d22fc2d2fddda6058579039eab6c4a2a7e78ecbcdd1b028b","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860005"],"TypeOfChange":"1","Version":"4.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28 OCP3アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-12-29T08:12:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<p>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<p>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</p>","Lang":"cn"}],"Version":"4.20"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品はResetToDefaultプロパティ（RDEポートスキーマ）をサポートするようになりました。</p>","Fixes":"<ul><li>この製品は、InterfaceEnabledプロパティが読み取り専用であり、このプロパティにパッチを適用できない問題に対処します。</li><li>この製品は、UMCEが表示される問題に対処します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product now supports&nbsp; ResetToDefault property(RDE Port Schema).</p>","Fixes":"<ul><li>This product addresses an issue where InterfaceEnabled property is read only and it can&#39;t patch this property</li><li>This product addresses an issue where UMCE is seen</li></ul>","Lang":"cn"}],"Version":"4.20"}],"SWKeys":[{"Name":"INTEL_E810_XXV2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"84fe25dfa01541dab8032754930854c8"}]},{"ProductId":"8624b0ddbb9d42cbac863b6eec3917ae","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR216i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.26.3.5487"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The ESXi Smart Component provides controller firmware for HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ESXi Smartコンポーネントは、HPE MR216i-p Gen10 Plusトライモードコントローラー用のコントローラーファームウェアを提供します"},{"Lang":"cn","Value":"The ESXi Smart Component provides controller firmware for HPE MR216i-p Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>HPEMR216i-p Online FW Update with OS command option.</p>"},{"Lang":"ja","Value":"<p>OSコマンドオプションを使用したHPEMR216i-pオンラインFWアップデート。</p>"},{"Lang":"cn","Value":"<p>HPEMR216i-p Online FW Update with OS command option.</p>"}],"Files":[{"Bytes":"13070258","DateModified":"2025-03-07T06:01:26","FileList":["/CP066015_BUILD_6.data","/CP066015.vmexe64","/CP066015.vmfile","/CP066015_VMw.zip","/CP066015.xml","/payload.json","/CP066015_VMw.zip/index.xml","/CP066015_VMw.zip/vendor-index.xml","/CP066015_VMw.zip/metadata.zip","/CP066015_VMw.zip/vib20/CP066015/HPE_bootbank_CP066015_52.26.3.5487.6-8.0.0.20613240.vib","/CP066015_VMw.zip/metadata.zip/vendor-index.xml","/CP066015_VMw.zip/metadata.zip/vmware.xml","/CP066015_VMw.zip/metadata.zip/vibs/CP066015--5512224417329655375.xml","/CP066015_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066015_52.26.3.5487.6-8.0.0.20613240.xml"],"MD5Sum":"64c7730a36b6f86d1b58daf0396269f7","Name":"CP066015.zip","Release":"2025-03-07T06:00:56","Revision":"B","SHA1Sum":"7ee7e7a2734686ac1937365506592ad179540555","SHA256Sum":"fdf2bdd835a62c1ed62657ed3f95a59502fa5bfe8c0b82a3dd28f2e509869435","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032b"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP066015","Version":"52.26.3.5487.6-8.0.0.20613240"}]}],"Installation":{"Command":"CP066015.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"ja","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"cn","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"Lang":"cn","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-p Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T03:33:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>PLDMファームウェアアップデートが失敗する可能性がある問題を修正します。この問題は、コントローラー、バックプレーン、およびコントローラーに接続されたドライブで発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"cn"}],"Version":"52.26.3.5487"},{"ReleaseNotes":[{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"cn"}],"Version":"52.26.3.5487"}],"SWKeys":[{"Name":"032B1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5839c976f25e48398417f7338f355dfe"}]},{"ProductId":"799046a4ae3d4743be83cc950a1f1f68","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"28163179","DateModified":"2025-03-07T08:15:24","FileList":["/CP065660_BUILD_2.data","/CP065660.vmexe64","/CP065660.vmfile","/CP065660_VMw.zip","/CP065660.xml","/payload.json","/CP065660_VMw.zip/index.xml","/CP065660_VMw.zip/vendor-index.xml","/CP065660_VMw.zip/metadata.zip","/CP065660_VMw.zip/vib20/CP065660/HPE_bootbank_CP065660_8.55.12.2-1OEM.900.0.24580437.vib","/CP065660_VMw.zip/metadata.zip/vendor-index.xml","/CP065660_VMw.zip/metadata.zip/vmware.xml","/CP065660_VMw.zip/metadata.zip/vibs/CP065660-4554546092090114858.xml","/CP065660_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065660_8.55.12.2-1OEM.900.0.24580437.xml"],"MD5Sum":"002e144815c390a33394cc5ab328dedd","Name":"CP065660.zip","Release":"2025-03-07T08:13:58","Revision":"B","SHA1Sum":"e89488a1cc4103e463075a20017f993a1536462b","SHA256Sum":"463c4edece7068202675f282a957c65916de0bf397996b0dbfbabd515b2c0330","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12","VibList":[{"Name":"CP065660","Version":"8.55.12.2-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"ja","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for VMware"},{"Lang":"cn","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-13T08:40:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"en"},{"Enhancements":"<p>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</p>","Fixes":"<p>この製品は、iPXEブートを試行しているときのスイッチのPause Flood状態に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"16812b1e5cfb47c5a13a2e8e320d8624"}]},{"ProductId":"151db6b708e24a74b7dabf5cd99dd77a","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Windows Server 2019 and Windows Server 2022."},{"Lang":"ja","Value":"このパッケージには、Windows Server 2019およびWindows Server 2022で動作するHPE ProLiant Broadcom NetXtreme-E Ethernet NICのブートコード、PXE、UMP、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"11822272","DateModified":"2025-11-20T07:46:43","FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp069752.xml","cpqsetup.exe","FW/","FW/BCM957412A4121HC.pkg","FW/BCM957412N4120HC.pkg","FW/BCM957414A4142HC.pkg","FW/BCM957414N4140HC.pkg","FW/BCM957416A4162HC.pkg","FW/BCM957416N4160HC.pkg","FW/BCM957504A504H.pkg","FW/BCM957504N504H.pkg","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"f3d341806a37a70f319d242265e9d2ac","Name":"cp069752.exe","Release":"2025-11-20T07:38:50","Revision":"C","SHA1Sum":"b6edb534cf50283c454153e55f25e513e19a2268","SHA256Sum":"63d8a1cfaaf90b26ce68f2d25613b1c707311367885c85fc44f4e4d6400129c9","Size":"11MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599"],"TypeOfChange":"1","Version":"226.1.107.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティfor Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-12-20T06:55:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、デバイスの自己診断マトリックスとMAC検証を強化しました。</li><li>この製品は、内部変数のリンク速度計算を強化しました。</li></ul>","Fixes":"<ul><li>この製品は、BCM57414 OCP3アダプターでの継続的な強制再起動後にデバイスが失われる症状に対処しました。</li><li>この製品は、一部のLLDPプロパティの一部のRDEパターン形式に対処しました。</li><li>この製品は、デバイスがアイドルモードにあるときのBMCによるNC-SIパススルーに対処しました。</li><li>この製品は、工場出荷時のデフォルトをロードする場合の新しいメカニズムに対処しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"cn"}],"Version":"226.1.107.0"}],"SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"6a3469b568764167a98158c4c05fab90"}]}],"SchemaVersion":"1.0"}